www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
1INSTALLATION INSTRUCTIONS
F-4260_091118
Luminaire for Parking GaragesTEKDEK™ LED
IMPORTANT SAFEGUARDSWhen using electrical equipment, basic safety precautions should
always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
CE PRODUIT DOIT ÊTRE INSTALLÉ EN CONFORMITÉ AVEC LE CODE DE L'INSTALLATION PAR UNE PERSONNE QUI connaît BIEN LA CONSTRUCTION ET
LE FONCTIONNEMENT DU PRODUIT ET LES RISQUES ENCOURUS.
DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT
CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS
INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONSSAFETY RECOMMENDATION
TD17 SERIES
SAFETY RECOMMENDATIONA 1/16" diameter aircraft cable with end-loop (not included) is recommended for attaching the �xture structural to the upper structural.
1/16" DIA. AIRCRAFT CABLE(SUPPLIED BY OTHERS)
AIRCRAFT CABLE ATTACHTO UPPER STRUCTURAL
SCREW (SUPPLIED BY OTHERS)
A 1/16" diameter cable with end-loop (not included) is recommended for attaching the fi xture structural to the upper structural
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
2INSTALLATION INSTRUCTIONS
F-4260_091118
1: Remove tertiary lens (if provided) by unscrewing (4) captive screws.
2: Remove heatsinking/LED base by unscrewing (4) captive screws. These will be the inner most screws.
3: Disconnect the quick connector wires from the LED board and the driver.
4: Make electrical connection to J-box (for sizes, see next page). Circuit wire connection must be in J-box. Install housing to surface using (4) 5/16" diameter mounting holes.
5: Re-assemble by reversing the removal procedure.
DRIVERQUICK CONNECT HEATSINK/LED BASE
CAPTIVE SCREWS (4) FOR REMOVING HEATSINK
CAPTIVE SCREWS (4)
TERTIARY LENS (IF PROVIDED)
HOUSING
HOUSING TOP VIEW
5/16” MOUNTING HOLES (4)
DIRECT TO SURFACE INSTALLATION
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
2INSTALLATION INSTRUCTIONS
F-4258_091118
QUICK MOUNT KIT INSTALLATION
1: Quick mount plate fastens to a secure J-box. Screws by others.
2: Align hanger bracket with center slot on top of fi xture as shown at right. Fixture can then hang from bracket while electrical connections are made.
3: After excess wires are in J-box (see sizes below), push the fi xture up to the mounting plate. Locking hooks should slide through slots. Twist fi xture until a “click” is felt or heard. Fixture is now in place.
LOCKING HOOKS
HANGER BRACKET QUICK MOUNT PLATE
1.
2. ALIGN HANGER BRACKETWITH CENTER SLOT
LOCKING HOOK SLOTS
3.
USED WITH THE FOLLOWING JUNCTION BOX SIZES:4" ROUND 4" SQUARE3-1/2" OCTAGON
3.37
3.37
2.50
2.50
4.773.50
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
2INSTALLATION INSTRUCTIONS
F-4557_041013
BIRD GUARD INSTALLATION
1. Fasten tab through slots as shown above.
No tools required. Must install before fi xture is mounted.
2. Bird Guard lays inside of casting.
DIRECT TO SURFACE & QUICK MOUNT
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
2INSTALLATION INSTRUCTIONS
F-4259_091118
PENDANT MOUNT INSTALLATION
1: Attach 3/4" threaded conduit to housing (provided by others).
2: Make electrical connections in conduit body (supplied by others).
CONDUIT BODY AND CONDUIT (BY OTHERS)
HOUSING TAPPED FOR 3/4” NPS THREAD
MUST USE SEALANT OR SEALING LOCKNUT
SWIVEL MOUNT NOT RECOMMENDED (Kenall does not supply counterbalance system)
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
2INSTALLATION INSTRUCTIONS
F-4257_091118
TRUNNION KIT INSTALLATION
1: Attach housing plate to housing. Align notch. Use (4) fl at head screws (provided).
2: Assemble trunninon kits as shown using (4) ¼ -20 × .500" screws and nuts (provided).
3: Attach trunnion brackets to housing plate with (4) 10-32 × .375" hex head screws (provided).
4: Make electrical connections in conduit body (supplied by others). Attach ¾” NPT conduit hub (supplied by others) between conduit and J-box.
NOTE: Top of bracket to top of the fi xture measurements: 9.1" min; 14.6" max
TRUNNION BRACKETS
CONDUIT BODY AND CONDUIT (BY OTHERS)
HOUSING PLATE
HOUSING
(To increase depth, move this fastner here)
MUST USE SEALANT OR SEALING LOCKNUT
CONDUIT HUB(BY OTHERS)
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
1INSTALLATION INSTRUCTIONS
F-4558_041013
Luminaire for Parking GaragesTEKDEK™ LED
1. Bird Guard lays on top of casting.
TD17 SERIESIMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
CE PRODUIT DOIT ÊTRE INSTALLÉ EN CONFORMITÉ AVEC LE CODE DE L'INSTALLATION PAR UNE PERSONNE QUI connaît BIEN LA CONSTRUCTION ET LE FONCTIONNEMENT DU PRODUIT ET LES RISQUES ENCOURUS.
DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
Pendant Mount
Trunnion Kit
BIRD GUARD INSTALLATION - PENDANT MOUNT & TRUNNION KIT
(For Trunnion Kit remove tabs)
2. Attach both sides with (4) screws provided.
NOTE: For LEL option, align hole in bird guard with LED indicator
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
3INSTALLATION INSTRUCTIONS
F-4257_091118
MOUNT FIXTURE WITH REGARDS TO OPTICAL ALIGNMENT KEY DIRECTION
TYPES II, III, IV
TYPE V, NORMALTYPE V, SQUARE
TYPE II
TYPE III
TYPE IV
TYPE VNORMAL
TYPE VSQUARE
LIGHT DISTRIBUTION PATTERN TYPES
DRIVING LANE
DRIVING LANE
KEY OPTICALALIGNMENT KEY
For warranty information visit www.kenall.com/Resources/Certified-Performance-Warranties
For technical assistance, call 1-800-4KENALL (1-800-453-6255).
WARRANTY
CUSTOMER SERVICE
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of speci�cation sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
9INSTALLATION INSTRUCTIONS
F-4257_041013