Insight® Product Reference Guide

May 2017

IM MerchandisersPages 39 - 44

IDD5 MerchandisersPages 22 - 26

IC Merchandisers Pages 2 - 13

ID5 Merchandisers Pages 14 - 21

ID6 Merchandisers Pages 27 - 30

IDD6 Merchandisers Page 31 - 34

IP MerchandisersPages 45 - 50

ID Freedom Line MerchandisersPages 35 - 38

MAY 2017

NOTE REGARDING ALL PRODUCTS FEATURED:

These merchandisers are designed for use in stores when temperature and humidity do not exceed 75°F (23.9°C) and 55% R.H. Options are available on most models to adjust performance to Type II climatic conditions.

Locate cases away from direct sunlight, rapid air current and extreme temperature changes.

Hussmann reserves the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.

Measurements in this book are in both inches and millimeters. Parentheses indicate millimeters.

The drawings in this guide are for reference only. Please use Hussmann’s Technical Data Sheets for precise dimensions when doing store layout and design.

Insight®

Merchandisers

INSIGHT PRODUCT REFERENCE GUIDE 1

TWO VERSATILE STYLING OPTIONS*

ELLIPSEcanopy bumper

FACETEDcanopy bumper

OPTIONAL GLASS FRONT

this glass front option is available on selected models as specified in the

following pages.

7 1/4(184)

*available on most cases. contact your representative for details.

2

IC2NL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsNarrow Front-to-Back Depth, Low Front

LOAD LI

MIT LI

NE

39 1/2(1003)

19 1/2(495) 15 1/2

(394)

50 3/8(1280)

25 1/4(641)

29 7/8(759)

5(127)

IC2NL

31 1/2(800)

21 7/8(556)

27 7/8(708)

See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 3.3 ft3/ ft (0.307 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 3

IC2SL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Low Front

LOAD LI

MIT LIN

E

19 1/2(495) 15 1/2

(394)

50 3/8(1280)

30 1/8 (765)

32 1/4(819)

IC2SL

21 7/8(556)

5(127)

27 7/8(708)

44 3/8(1127)

36 3/8(924)

See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.

* Optional glass front available on this model. See page 1 for drawing and dimensions.

Gross Refrigerated Volume* – 3.9 ft3/ ft (0.36 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

4

IC2SM* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Medium Front

LOAD LIMIT LINE

19(483)

23(584)

50 3/8(1280)

29 1/2(749)

IC2SM

21 7/8(556)

5(127)

44 3/8(1127)

36 3/8(924)

27 7/8(708)

30 1/8 (765)

See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 4.2 ft3/ ft (0.39 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 5

IC2XNL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsExtra Tall, Narrow Front-to-Back Depth, Low Front

See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

31 1/2(800)

39 1/2(1003)

21 7/8(556)

19 1/2(495) 15 1/2

(394)

57 7/8(1470)

25 1/4(641)

36 1/4(921)

5(127)

IC2XNL

35(889)

* Optional glass front available on this model. See page 1 for drawing and dimensions.

Gross Refrigerated Volume* – 4.1 ft3/ ft (0.38 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

6

IC2XSL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsExtra Tall, Standard Front-to-Back Depth, Low Front

See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

36 3/8(924)

44 3/8(1127)

19 1/2(495) 15 1/2

(394)

30 1/8 (765)

37 5/8(956)

IC2XSL

23 3/8(594)

5(127)

57 5/8(1464)

35(889)

* Optional glass front available on this model. See page 1 for drawing and dimensions.

Gross Refrigerated Volume* – 4.9 ft3/ ft (0.46 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 7

IC2XSM* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsExtra Tall, Standard Front-to-Back Depth, Medium Front

See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIMIT

LINE

36 3/8(924)

44 3/8(1127)

30 1/8 (765)

34 1/2(876)

IC2XSM

23 3/8(594)

5(127)

57 5/8(1464)

19(483)

23(584)

35(889)

* Optional glass front available on this model. See page 1 for drawing and dimensions.

Gross Refrigerated Volume* – 5.2 ft3/ ft (0.48 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

8

IC3BL* Insight Convertible 3-Deck Merchandiser for High Volume Bulk ApplicationsStandard Front-to-Back Depth, Low Front

LOAD

LIM

IT L

INE

40 1/4(1022)

48 1/4(1226)

34 (864)

41 7/8(1064)

IC3BL

24 5/8(625)

5(127)

61(1549)

15 1/2(394)

19 1/2(495)

39 5/8(1006)

See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 6.0 ft3/ ft (0.56 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 9

IC3SL* Insight Convertible 3-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Low Front

LOAD

LIM

IT L

INE

36 3/8(924)

44 3/8(1127)

19 1/2(495) 15 1/2

(394)

30 1/8 (765)

47 3/8(1203)

IC3SL

23 3/8(594)

5(127)

68 1/4(1734)

45 5/8(1159)

See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 6.3 ft3/ ft (0.59 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

10

IC4BM* Insight Convertible 4-Deck Merchandiser for High Volume Bulk ApplicationsStandard Front-to-Back Depth, Medium Front

LOAD

LIM

IT L

INE

25 3/4(652)

29 5/8(752)

83 1/4(2115)

43 7/8(1114)

9 1/4(235)

43 7/8(1114)

34 1/8(867)

53 3/8(1356)

39 1/2(1003)

47 1/2(1207)

IC4BMSee Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 10.9 ft3/ ft (1.01 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 11

IC4SL* Insight Convertible 4-Deck Merchandiser for Medium Temperature ApplicationsStandard Front-to-Back Depth, Low Front

LOAD

LIM

IT L

INE

22 1/8(562)

26 1/8(664)

83 1/4(2115)

43 7/8(1114)

9 1/4(235)

47 1/4(1200)

30 1/8(765)

52 1/8(1324)

35 5/8(905)

43 5/8(1108)

IC4SLSee Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 10.15 ft3/ ft (0.94 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

12

IC6SL* Insight 6-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Low Front

LOAD

LIM

IT L

INE

15 1/2(394)

19 1/2(495)

43 7/8(1114)

9 1/4(235)

60 1/4(1530)

30 1/8(765)

64 7/8(1648)

IC6SL

43 5/8(1108)

35 5/8(905)

89 5/8(2276)

See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 12.7 ft3/ ft (1.18 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 13

IC6SM* Insight 6-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Medium Front

LOAD

LIM

IT L

INE

19(483)

23(584)

30 1/8(765)

IC6SM

43 7/8(1114)

9 1/4(235)

56 3/4(1441)

83 1/4(2115)

65 1/8(1654)

35 5/8(905)

43 5/8(1108)

See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 12.8 ft3/ ft (1.19 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

14

ID5NL* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsNarrow Front-to-Back Depth, Low Front

See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.

30 5/8(778)

38 5/8(981)

39(991)

19 1/2(495) 15 1/2

(394)

25 1/4 (641)

59 1/4 (1505)

54 5/8(1387)

9 1/4(235)

ID5NL

84(2134)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 15

ID5NM* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsNarrow Front-to-Back Depth, Medium Front

See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.

39(991)

23(584) 19

(483)

25 1/4 (641)

59 1/4 (1505)

51 1/8(1299)

9 1/4(235)

ID5NM

38 5/8(981)

30 5/8(778)

84(2134)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

16

ID5SL* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.

43 7/8(1114)

35 5/8(905)

15 1/2(394)

19 1/2(495)

59 1/4 (1505)

54 5/8(1387)

43 5/8(1108)

9 1/4(235)

ID5SL

30 1/8 (765)

84(2134)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 17

ID5SL-R* Insight 5-Deck Merchandiser for Dairy and Deli Applications Standard Front-to-Back Depth, Low Front, Rear Sliding Doors

See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.

COOLER

1 1/4(32)

43 7/8(1114)

35 5/8(905)

15 1/2(394)

19 1/2(495)

59 1/4 (1505)

54 5/8(1387)

43 5/8(1108)

9 1/4(235)

ID5SL-R

30 1/8 (765)

84(2134)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

18

ID5SM* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Medium Front

See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.

43 7/8(1114)

35 5/8(905)

19(483)

23(584)

59 1/4 (1505)

51 1/8(1299)

43 5/8(1108)

9 1/4(235)

ID5SM

30 1/8 (765)

84(2134)

LOAD

LIM

IT L

INE

* Optional glass front available on this model. See page 1 for drawing and dimensions.

Gross Refrigerated Volume* – 11.7 ft3/ ft (1.09 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 19

COOLER

1 1/4(32)

43 7/8(1114)

35 5/8(905)

59 1/4 (1505)

51 1/8(1299)

43 5/8(1108)

9 1/4(235)

ID5SM-R

30 1/8 (765)

84(2134)

23(584) 19

(483)

LOAD

LIM

IT L

INE

ID5SM-R* Insight 5-Deck Merchandiser for Dairy and Deli Applications Standard Front-to-Back Depth, Medium Front, Rear Sliding Doors

See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 11.7 ft3/ ft (1.08 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

20

ID5SU Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Ultra Low Front

84 7/8(2156)

43 1/2(1105)

35 1/2(902)

11 1/8(283)

14 1/2(368)

29 7/8 (759)

64 3/8 (1635)

60 1/2(1537)

9 1/4(235)

43 7/8(1114)

ID5SU

LOAD

LIM

IT L

INE

See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 21

ID5SV Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Very Low Front

88 1/4(2242)

43 1/2(1105)

35 1/2(902)

17 1/4(438)

30(762)

64 1/2 (1638)

43 7/8(1114)

ID5SV

13 7/8(352)

9 1/4(235)

60 1/2(1537)

LOAD

LIM

IT L

INE

See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

22

IDD5NL Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Narrow Front-to-Back Depth, Low Front

See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.

22 1/2(572)

21 1/2(546) 15 1/2

(394)

25 1/4 (641)

59 1/4 (1505)

DoorOpening

51 1/2(1308)

10 1/2(267)

IDD5NL

38 5/8(981)

30 5/8(778)

84(2134)

39(991)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 23

IDD5SL Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVsion Glass Doors, Standard Front-to-Back Depth, Low Front

See Plan View (page 57)Available in 4’, 6’, 8’ and 12’ lengths.

43 7/8(1114)

35 5/8(905)

15 1/2(394)

21 1/2(546)

30 1/8 (765)

59 1/4 (1505)

43 5/8(1108)

10 1/2(267)

DoorOpening

53(1346)

22 1/2(572)

IDD5SL

84(2134)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

24

IDD5SL-R Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Low Front, Rear Sliding Doors

See Plan View (page 57)Available in 4’, 6’, 8’ and 12’ lengths.

COOLER

43 7/8(1114)

35 5/8(905)

15 1/2(394)

21 1/2(546)

30 1/8 (765)

59 1/4 (1505)

43 5/8(1108)

10 1/2(267)

DoorOpening

53(1346)

22 1/2(572)

IDD5SL-R

1 1/4(32)

84(2134)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 25

IDD5SU Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front

See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.

84 7/8(2156)

43 1/2(1105)

35 1/2(902)22 5/8

(575)

15 3/8(391)

29 7/8 (759)

64 3/8 (1635)

DoorOpening

58 3/8(1483)

10 1/2(267)

43 7/8(1114)

IDD5SU

11 1/8(283)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

26

IDD5SV Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Very Low Front

See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.

88 1/4(2242)

43 1/2(1105)

35 1/2(902)22 5/8

(575)

17 7/8(454)

29 7/8 (759)

64 3/8 (1635)

DoorOpening

58 3/8(1483)

43 7/8(1114)

IDD5SV

13 7/8(352)

10 3/4(273)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 27

ID6NL* Insight 6-Deck Merchandiser for Dairy and Deli ApplicationsNarrow Front-to-Back Depth, Low Front

See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.

39(991)

19 1/2(495) 15 1/2

(394)

89 5/8(2276)

25 1/4 (641)

64 7/8 (1648)

60 1/4(1530)

9 1/4(235)

ID6NL

30 5/8(778)

38 5/8(981)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 10.4 ft3/ ft (0.97 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

28

ID6SU Insight 6-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Ultra Low Front

See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.

90 7/8(2308)

43 1/2(1105)

35 1/2(902)

14 1/2(368)

70 3/8 (1788)

66 1/2(1689)

9 1/4(235)

43 7/8(1114)

ID6SU

29 7/8 (759)

11 1/8(283)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 29

ID6SU-R Insight 6-Deck Merchandiser for Dairy and Deli Applications Extra Tall, Standard Front-to-Back Depth, Ultra Low Front, Rear Sliding Doors

See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.

COOLER

1 1/4(32)

43 1/2(1105)

35 1/2(902)

14 1/2(368)

70 3/8 (1788)

66 1/2(1689)

9 1/4(235)

43 7/8(1114)

ID6SU-R

29 7/8 (759)

11 1/8(283)

90 7/8(2308)LO

AD L

IMIT

LIN

E

Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

30

ID6SV Insight 6-Deck Merchandiser for Dairy and Deli ApplicationsExtra Tall, Standard Front-to-Back Depth, Very Low Front Lip

See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.

43 1/2(1105)

35 1/2(902)

66 3/8 (1686)

62 5/8(1591)

9 1/4(235)

43 7/8(1114)

ID6SV

17 1/4(438) 13 7/8

(352)

29 7/8 (759)

89 5/8(2276)LO

AD L

IMIT

LIN

E

Gross Refrigerated Volume* – 12.7 ft3/ ft (1.18 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 31

22 1/2(572)

39(991)

21 1/2(546)

89 5/8(2276)

25 1/4 (641)

64 7/8 (1648)

10 1/2(267)

IDD6NL

DoorOpening

57 1/4(1454)

15 1/2(394)

38 5/8(981)

30 5/8(778)

LOAD

LIM

IT L

INE

IDD6NL Insight 6-Deck Merchandiser for Dairy and Deli Applicationswith EcoVision Glass Doors, Narrow Front-to-Back Depth, Low Front

See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 10.4 ft3/ ft (0.97 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

32

IDD6SU Insight 6-Deck Merchandiser for Dairy and Deli Applicationswith EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front

See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

43 7/8(1114)

15 3/8(391)

10 1/2(267)

DoorOpening64 1/4(1632)

IDD6SU

11 1/8(283)

22 5/8(575)

29 7/8 (759)

90 7/8(2308)

43 1/2(1105)

35 1/2(902)

70 3/8 (1788)

Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 33

IDD6SU-R Insight 6-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front, Rear Sliding Doors

See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.

COOLER

LOAD

LIM

IT L

INE

43 7/8(1114)

15 3/8(391)

10 1/2(267)

DoorOpening64 1/4(1632)

IDD6SU-R

11 1/8(283)

22 5/8(575)

29 7/8 (759)

43 1/2(1105)

35 1/2(902)

70 3/8 (1788)

1 1/4(32)

90 7/8(2308)

Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

34

IDD6SV Insight 6-Deck Merchandiser for Dairy and Deli Applicationswith EcoVision Glass Doors, Standard Front-to-Back Depth, Very Low Front

See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.

90 1/4(2292)

43 1/2(1105)

35 1/2(902)22 5/8

(575)

17 7/8(454)

29 7/8 (759)

66 3/8 (1686)

DoorOpening

58 1/2(1486)

IDD6SV

13 7/8(352)

12 3/4(324)

43 7/8(1114)

10 3/4(273)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 12.4 ft3/ ft (1.15 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 35

IDF5NM* Insight 5-Deck Freedom Line Merchandiser for Dairy ApplicationsNarrow Front-to-Back Depth, Medium Front

LOAD

LIM

IT L

INE

19(483)

23(584)

51 1/2(1308)

59 1/4(1505)

25 1/4(641)

20 1/8(511)

29 1/4(743)

38 3/4(984)

84(2133)

103 1/2(2629)

IDF5NM

38 5/8(981)

31 5/8(803)

1/2(13)

See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

36

IDF5SM* Insight 5-Deck Freedom Line Merchandiser for Dairy ApplicationsStandard Front-to-Back Depth, Medium Front

LOAD

LIM

IT L

INE

59 1/4(1505)

30 1/8(765)

43 5/8(1108)

IDF5SM

1/2(13)

35 5/8(905)

43 5/8(1108)

19(483)

51 3/8(1305)

20 1/8(511)

29 1/4(743)

23(584)

84(2133)

103 1/2(2629)

See Plan View (page 59)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 11.7 ft3/ ft (1.09 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 37

IDDF5SU Insight Freedom Line 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front

See Plan View (page 59)Available in 4’, 6’, 8’ and 12’ lengths.

15 1/4(387)

31(787)

11 1/8(283)

104 1/2(2654)

44 3/8(1127)

36 3/4(933)

1 1/8(29)

64 3/8(1635)

84 7/8(2156)

29 7/8(759)

20 1/4(514)

44 5/8(1133)

IDDF5SU

DoorOpening58 1/4(1480)

22 5/8(575)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

38

IDDF6SV Insight Freedom Line 6-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Very Low Front

See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.

90 1/4(2292)

43 1/2(1105)

35 1/2(902)22 5/8

(575)

17 7/8(454)

29 7/8 (759)

66 3/8 (1686)

DoorOpening

58 1/2(1486)

IDDF6SV

13 7/8(352)

12 3/4(324)

43 5/8(1108)

20 1/4(514)

109 1/4(2775)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 12.4 ft3/ ft (1.15 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 39

IM1SL* Insight Single-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD LIMIT LINE

IM1SL

8 5/8(219)

42 1/8(1070)

26 1/8(664)

30 1/8(765)

35 5/8(905)

43 5/8(1108)

30 7/8(784)

30 1/8(765)

Gross Refrigerated Volume* – 1.7 ft3/ ft (0.16 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

40

IM1SM* Insight Single-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Medium Front

See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD LIMIT LINE

IM1SM

8 5/8(219)

29 1/2(749)

30 1/8(765)

38 1/8(968)

25 3/4(654)

29 5/8(752)

35 5/8(905)

43 5/8(1108)

Gross Refrigerated Volume* – 1.7 ft3/ ft (0.158 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 41

* Optional glass front available on this model. See page 1 for drawing and dimensions.

IM3SL

30 1/8(765)

9 1/4(235)

36 1/8(918)

40 1/2(1029)

36 1/2(927)

30 1/8(765)

26 1/4(667)

75 3/4(1924)

35 5/8(905)

43 5/8(1108)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 7.0 ft3/ ft (0.65 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

IM3SL* Insight 3-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.

42

IM4SL* Insight 4-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

IM4SL

36 1/2(927)

26 1/8(664)

22 1/4(565)

75 7/8(1927)

30 1/8(765)

9 1/4(235)

40 1/8(1019)

44 1/2(1130)

35 5/8(905)

43 5/8(1108)

Gross Refrigerated Volume* – 7.7 ft3/ ft (0.72 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 43

IM5NL* Insight 5-Deck Merchandiser for High Volume Meat ApplicationsNarrow Front-to-Back Depth, Low Front

See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

30 5/8(778)

36 1/2(927)

22 3/4(578) 18 7/8

(479)

25 1/4(641)

9 1/4(235)

47 3/8(1203)

52(1321)

IM5NL

79 7/8(2028)

38 5/8(981)

Gross Refrigerated Volume* – 7.85 ft3/ ft (0.73 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

44

IM5SL* Insight 5-Deck Merchandiser for High Volume Meat ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

36 1/2(927)

22 3/4(578) 18 3/4

(476)

79 7/8(2028)30 1/8

(765)

47 1/4(1200)

51 7/8(1318)

IM5SL

9 1/4(235)

35 5/8(905)

43 5/8(1108)

Gross Refrigerated Volume* – 8.9 ft3/ ft (0.83 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

* Optional glass front available on this model. See page 1 for drawing and dimensions.

INSIGHT PRODUCT REFERENCE GUIDE 45

IP1SL Insight Single-Deck Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 1.67 ft3/ ft (0.16 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

LOAD LIMIT LINE

IP1SL

8 5/8(219)

30 1/8(765)

42 1/8(1070)

26 1/4(667)

30 1/8(765)

35 5/8(905)

43 5/8(1108)

30 3/4(781)

46

IP1XSL Insight Single-Deck Extra Tall Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 2.34 ft3/ ft (0.22 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

LOAD LIMIT LINE

IP1XSL

8 5/8(219)

30 1/8(765)

48 5/8(1235)

26 1/4(667)

30 1/8(765)

35 5/8(905)

43 5/8(1108)

32 7/8(835)

INSIGHT PRODUCT REFERENCE GUIDE 47

IP1XXSL Insight Single-Deck Extra-Extra Tall Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.

Gross Refrigerated Volume* – 2.77 ft3/ ft (0.26 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

LOAD LIMIT LINE

IP1XXSL

8 5/8(219)

30 1/8(765)

52 5/8(1337)

26 1/4(667)

30 1/8(765)

35 5/8(905)

43 5/8(1108)

34 5/8(879)

48

LOAD

LIM

IT L

INE

35 5/8(905)

36 1/2(927)

43 5/8(1108)

30 1/8(765)

26 1/8(664)

75 3/4(1924)

30 1/8(765)

9 1/4(235)

36 1/8(918)

40 1/2(1029)

IP2SL

Gross Refrigerated Volume* – 7.0 ft3/ ft (0.65 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

IP2SL Insight 2-Deck Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.

INSIGHT PRODUCT REFERENCE GUIDE 49

IP4NL Insight 4-Deck Merchandiser for Produce ApplicationsNarrow Front-to-Back Depth, Low Front

See Plan View (page 62)Available in 4’, 6’, 8’ and 12’ lengths.

IP4NL

22 1/8(562)

26 1/8(664)

52(1321)

47 3/8(1203)

9 1/4(235)

25 1/4(641)

83 1/4(2115)

38 5/8(981)

36 1/2(927)

30 5/8(778)

LOAD

LIM

IT L

INE

Gross Refrigerated Volume* – 7.85 ft3/ ft (0.73 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

50

IP4SL Insight 4-Deck Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front

See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.

LOAD

LIM

IT L

INE

35 5/8(905)

36 1/2(927)

43 5/8(1108)

26 1/8(664)

22 1/8(562)

79 7/8(2028)

30 1/8(765)

9 1/4(235)

47 1/4(1200) 51 7/8

(1318)

IP4SL

Gross Refrigerated Volume* – 8.9 ft3/ ft (0.83 m3/ m)

*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation

INSIGHT PRODUCT REFERENCE GUIDE 51

Plan View IC2SL and IC2SM

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

SplashguardRefrigeration OutletField ElectricalConnectionat BOTTOMof Case

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

7(178)

7(178)

3 5/8(92)

36 3/8(924)

21 7/8(556)

44 3/8(1127)

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

Plan View IC2NL and IC2XNL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutletWireway in Canopy

WasteOutlet

Splashguard

Field ElectricalConnectionat BOTTOMof Case

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

7(178)

7(178)

3 5/8(92)

31 1/2(800)

21 7/8(556)

39 1/2(1003)

52

Plan View IC2XSL, IC2XSM, and IC3SL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

SplashguardRefrigeration OutletField ElectricalConnectionat BOTTOMof Case

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

7(178)

7(178)

3 5/8(92)

36 3/8(924)

23 3/8(594)

44 3/8(1127)

Plan View IC3BL

Refrigeration OutletRefrigeration

Outlet

Field ElectricalConnectionat BOTTOMof Case

Splashguard

Waste Outlet

Wireway in Canopy

7(178)

7(178)

48 1/4(1226)

40 1/4(1022)

25 3/8(645)

A

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

FRONT

1 1/2 Inch(38 mm)RequiredAir Gap

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

53INSIGHT PRODUCT REFERENCE GUIDE

Plan View IC4SL, IC6SL, IC6SM, ID5SL, and ID5SM

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

1 1/2 Inch(38 mm)RequiredAir Gap

Refrigeration Outlet

RefrigerationOutlet

Waste Outlet

Wireway in CanopySplashguard

FRONT

3 5/8(92)

7(178)

7(178)

A

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

35 5/8(905)

43 5/8(1108)

43 7/8(1114)

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Field ElectricalConnectionat TOPof Case

Plan View IC4BM

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

7(178)

7(178)

47 1/2(1207)

39 1/2(1003)

A

FRONT

RefrigerationOutlet

RefrigerationOutletField

ElectricalConnection

at TOPof Case

Splashguard

Waste Outlet

1 1/2 Inch(38 mm)RequiredAir Gap

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

54

Plan View ID5SL-R and ID5SM-R

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

COOLER

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

FRONT

7 (178) 7 (178) 3 5/8 (92) A

35 5/8(905)

43 5/8(1108)

43 7/8(1114)

Field ElectricalConnectionat TOPof Case

Plan View ID5NL, ID5NM, and ID6NL

1 1/2 Inch(38 mm)RequiredAir Gap

RefrigerationShroud

Wireway in Canopy

WasteOutlet

Splashguard

FRONT

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

A

30 5/8(778)

39(991)

38 5/8(981)

7(178)

7(178)

3 5/8(92)

Field ElectricalConnectionat TOPof Case

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

INSIGHT PRODUCT REFERENCE GUIDE 55

Plan View ID5SU and ID5SV

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

Plan View ID6SU and ID6SV

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

43 1/2(1105)

35 1/2(902)

43 7/8(1114)

1 1/2 Inch(38 mm)RequiredAir Gap

7(178)

7(178)

3 5/8(92)

Field ElectricalConnectionat TOPof Case

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

43 1/2(1105)

35 1/2(902)

43 7/8(1114)

1 1/2 Inch(38 mm)RequiredAir Gap

7(178)

7(178)

3 5/8(92)

Field ElectricalConnectionat TOPof Case

56

Plan View ID6SU-R and IDD6SU-R

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

COOLER

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

FRONT

7 (178) 7 (178) 3 5/8 (92) A

35 1/2(902)

81/2(216)

43 1/2(1105)

43 7/8(1114)

Field ElectricalConnectionat TOPof Case

Plan View IDD5NL and IDD6NL

RefrigerationShroud

Wireway in Canopy

WasteOutlet

Splashguard

Door Swing Clearance

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

7(178)

7(178)

3 5/8(92)

38 5/8(981)

30 5/8(778)

39(991)

22 1/2(572)

Field ElectricalConnectionat TOPof Case

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

INSIGHT PRODUCT REFERENCE GUIDE 57

Plan View IDD5SL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

Door Swing Clearance

7(178)

7(178)

3 5/8(92)

43 5/8(1108)

35 5/8(905)

43 7/8(1114)

22 1/2(572)

Field ElectricalConnectionat TOPof Case

COOLER

43 5/8(1108)

35 5/8(905)

43 7/8(1114)

22 1/2(572)

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

RefrigerationOutlet

Splashguard

Door Swing Clearance

WasteOutlet

RefrigerationOutlet

Wireway in Canopy

FRONT

A7 (178) 7 (178) 3 5/8 (92)

Field ElectricalConnectionat TOPof Case

Plan View IDD5SL-R

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

58

Plan View IDD5SU, IDD5SV, IDD6SU, and IDD6SV

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

Door Swing Clearance

43 1/2(1105)

35 1/2(902)

43 7/8(1114)

22 5/8(575)

7(178)

7(178)

3 5/8(92)

Field ElectricalConnectionat TOPof Case

Plan View IDF5NM

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

Splashguard

Waste OutletRefrigerationShroud

Wireway in Canopy

38 3/4(984)

38 5/8(981)

31 5/8(803)

3 1/2(89)

7(178)

7(178)

3 5/8(92)

1 1/2 Inch(38 mm)RequiredAir Gap

A

FRONT

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

Field ElectricalConnectionat TOPof Case

59INSIGHT PRODUCT REFERENCE GUIDE

Plan View IDDF5SU

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

Wireway in Canopy

WasteOutlet

Splashguard

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 1/2 (3670)

Door Swing Clearance

7(178)

7(178)

3 5/8(92)

44 3/8(1127)

36 3/4(933)

44 5/8(1133)

22 5/8(575)

Field ElectricalConnectionat TOPof Case

Plan View IDF5SM

1 1/2 Inch(38 mm)RequiredAir Gap

Refrigeration Outlet

RefrigerationOutlet

Waste Outlet

Wireway in CanopySplashguard

FRONT

3 5/8(92)

7(178)

7(178)

A

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

35 5/8(905)

43 5/8(1108)

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Field ElectricalConnectionat TOPof Case

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

60

Plan View IM1SL, IM1SM, IP1SL, IP1XSL, and IP1XXSL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

7(178)

7(178)

3 5/8(92)

43 5/8(1108)

35 5/8(905)

RefrigerationOutlet

RefrigerationOutlet Waste

Outlet

Splashguard

Field ElectricalConnectionat BOTTOMof Case

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Plan View IDDF6SV

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutlet

RefrigerationOutlet

Wireway in Canopy

WasteOutlet

Splashguard

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

Door Swing Clearance

43 1/2(1105)

35 1/2(902)

43 7/8(1114)

22 5/8(575)

7(178)

7(178)

3 5/8(92)

Field ElectricalConnectionat TOPof Case

INSIGHT PRODUCT REFERENCE GUIDE 61

Plan View IM3SL, IM4SL, IM5SL, IP2SL, and IP4SL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

RefrigerationOutletWaste

Outlet

Splashguard

1 1/2 Inch(38 mm)RequiredAir Gap

FRONT

A

Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

Wireway in Canopy

RefrigerationOutlet

Field ElectricalConnectionat TOPof Case

7(178)

7(178)

3 5/8(92)

36 1/2(927)

35 5/8(905)

43 5/8(1108)

Plan View IM5NL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

1 1/2 Inch(38 mm)RequiredAir Gap

RefrigerationShroud

Wireway in Canopy

WasteOutlet

Splashguard

FRONT

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

A

30 5/8(778)

38 5/8(981)

7(178)

7(178)

3 5/8(92)

31/2(89)Field Electrical

Connectionat TOPof Case

62

Plan View IP4NL

Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).

1 1/2 Inch(38 mm)RequiredAir Gap

RefrigerationShroud

Wireway in Canopy

WasteOutlet

Splashguard

FRONT

Dimensions 4 FT 6 FT 8 FT 12 FT

A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)

A

30 5/8(778)

38 5/8(981)

7(178)

7(178)

3 5/8(92)

31/2(89)Field Electrical

Connectionat TOPof Case

INSIGHT PRODUCT REFERENCE GUIDE 63

Notes

6464

Notes

IM MerchandisersPages 39 - 44

IDD5 MerchandisersPages 22 - 26

IC Merchandisers Pages 2 - 13

ID5 Merchandisers Pages 14 - 21

ID6 Merchandisers Pages 27 - 30

IDD6 Merchandisers Page 31 - 34

IP MerchandisersPages 45 - 50

ID Freedom Line MerchandisersPages 35 - 38

Hussmann Corporation 12999 St. Charles Rock Rd.Bridgeton, MO 63044-2483Ph: 314.291.2000

www.hussmann.com

Printed in U.S.A. ©2017 Hussmann CorporationInsight_PRG_052617

top related