NOTE REGARDING ALL PRODUCTS FEATURED:
These merchandisers are designed for use in stores when temperature and humidity do not exceed 75°F (23.9°C) and 55% R.H. Options are available on most models to adjust performance to Type II climatic conditions.
Locate cases away from direct sunlight, rapid air current and extreme temperature changes.
Hussmann reserves the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Measurements in this book are in both inches and millimeters. Parentheses indicate millimeters.
The drawings in this guide are for reference only. Please use Hussmann’s Technical Data Sheets for precise dimensions when doing store layout and design.
Insight®
Merchandisers
INSIGHT PRODUCT REFERENCE GUIDE 1
TWO VERSATILE STYLING OPTIONS*
ELLIPSEcanopy bumper
FACETEDcanopy bumper
OPTIONAL GLASS FRONT
this glass front option is available on selected models as specified in the
following pages.
7 1/4(184)
*available on most cases. contact your representative for details.
2
IC2NL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsNarrow Front-to-Back Depth, Low Front
LOAD LI
MIT LI
NE
39 1/2(1003)
19 1/2(495) 15 1/2
(394)
50 3/8(1280)
25 1/4(641)
29 7/8(759)
5(127)
IC2NL
31 1/2(800)
21 7/8(556)
27 7/8(708)
See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 3.3 ft3/ ft (0.307 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 3
IC2SL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Low Front
LOAD LI
MIT LIN
E
19 1/2(495) 15 1/2
(394)
50 3/8(1280)
30 1/8 (765)
32 1/4(819)
IC2SL
21 7/8(556)
5(127)
27 7/8(708)
44 3/8(1127)
36 3/8(924)
See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.
* Optional glass front available on this model. See page 1 for drawing and dimensions.
Gross Refrigerated Volume* – 3.9 ft3/ ft (0.36 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
4
IC2SM* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Medium Front
LOAD LIMIT LINE
19(483)
23(584)
50 3/8(1280)
29 1/2(749)
IC2SM
21 7/8(556)
5(127)
44 3/8(1127)
36 3/8(924)
27 7/8(708)
30 1/8 (765)
See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 4.2 ft3/ ft (0.39 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 5
IC2XNL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsExtra Tall, Narrow Front-to-Back Depth, Low Front
See Plan View (page 51)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
31 1/2(800)
39 1/2(1003)
21 7/8(556)
19 1/2(495) 15 1/2
(394)
57 7/8(1470)
25 1/4(641)
36 1/4(921)
5(127)
IC2XNL
35(889)
* Optional glass front available on this model. See page 1 for drawing and dimensions.
Gross Refrigerated Volume* – 4.1 ft3/ ft (0.38 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
6
IC2XSL* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsExtra Tall, Standard Front-to-Back Depth, Low Front
See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
36 3/8(924)
44 3/8(1127)
19 1/2(495) 15 1/2
(394)
30 1/8 (765)
37 5/8(956)
IC2XSL
23 3/8(594)
5(127)
57 5/8(1464)
35(889)
* Optional glass front available on this model. See page 1 for drawing and dimensions.
Gross Refrigerated Volume* – 4.9 ft3/ ft (0.46 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 7
IC2XSM* Insight Convertible 2-Deck Merchandiser for Multiple ApplicationsExtra Tall, Standard Front-to-Back Depth, Medium Front
See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIMIT
LINE
36 3/8(924)
44 3/8(1127)
30 1/8 (765)
34 1/2(876)
IC2XSM
23 3/8(594)
5(127)
57 5/8(1464)
19(483)
23(584)
35(889)
* Optional glass front available on this model. See page 1 for drawing and dimensions.
Gross Refrigerated Volume* – 5.2 ft3/ ft (0.48 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
8
IC3BL* Insight Convertible 3-Deck Merchandiser for High Volume Bulk ApplicationsStandard Front-to-Back Depth, Low Front
LOAD
LIM
IT L
INE
40 1/4(1022)
48 1/4(1226)
34 (864)
41 7/8(1064)
IC3BL
24 5/8(625)
5(127)
61(1549)
15 1/2(394)
19 1/2(495)
39 5/8(1006)
See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 6.0 ft3/ ft (0.56 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 9
IC3SL* Insight Convertible 3-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Low Front
LOAD
LIM
IT L
INE
36 3/8(924)
44 3/8(1127)
19 1/2(495) 15 1/2
(394)
30 1/8 (765)
47 3/8(1203)
IC3SL
23 3/8(594)
5(127)
68 1/4(1734)
45 5/8(1159)
See Plan View (page 52)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 6.3 ft3/ ft (0.59 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
10
IC4BM* Insight Convertible 4-Deck Merchandiser for High Volume Bulk ApplicationsStandard Front-to-Back Depth, Medium Front
LOAD
LIM
IT L
INE
25 3/4(652)
29 5/8(752)
83 1/4(2115)
43 7/8(1114)
9 1/4(235)
43 7/8(1114)
34 1/8(867)
53 3/8(1356)
39 1/2(1003)
47 1/2(1207)
IC4BMSee Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 10.9 ft3/ ft (1.01 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 11
IC4SL* Insight Convertible 4-Deck Merchandiser for Medium Temperature ApplicationsStandard Front-to-Back Depth, Low Front
LOAD
LIM
IT L
INE
22 1/8(562)
26 1/8(664)
83 1/4(2115)
43 7/8(1114)
9 1/4(235)
47 1/4(1200)
30 1/8(765)
52 1/8(1324)
35 5/8(905)
43 5/8(1108)
IC4SLSee Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 10.15 ft3/ ft (0.94 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
12
IC6SL* Insight 6-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Low Front
LOAD
LIM
IT L
INE
15 1/2(394)
19 1/2(495)
43 7/8(1114)
9 1/4(235)
60 1/4(1530)
30 1/8(765)
64 7/8(1648)
IC6SL
43 5/8(1108)
35 5/8(905)
89 5/8(2276)
See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 12.7 ft3/ ft (1.18 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 13
IC6SM* Insight 6-Deck Merchandiser for Multiple ApplicationsStandard Front-to-Back Depth, Medium Front
LOAD
LIM
IT L
INE
19(483)
23(584)
30 1/8(765)
IC6SM
43 7/8(1114)
9 1/4(235)
56 3/4(1441)
83 1/4(2115)
65 1/8(1654)
35 5/8(905)
43 5/8(1108)
See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 12.8 ft3/ ft (1.19 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
14
ID5NL* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsNarrow Front-to-Back Depth, Low Front
See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.
30 5/8(778)
38 5/8(981)
39(991)
19 1/2(495) 15 1/2
(394)
25 1/4 (641)
59 1/4 (1505)
54 5/8(1387)
9 1/4(235)
ID5NL
84(2134)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 15
ID5NM* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsNarrow Front-to-Back Depth, Medium Front
See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.
39(991)
23(584) 19
(483)
25 1/4 (641)
59 1/4 (1505)
51 1/8(1299)
9 1/4(235)
ID5NM
38 5/8(981)
30 5/8(778)
84(2134)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
16
ID5SL* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.
43 7/8(1114)
35 5/8(905)
15 1/2(394)
19 1/2(495)
59 1/4 (1505)
54 5/8(1387)
43 5/8(1108)
9 1/4(235)
ID5SL
30 1/8 (765)
84(2134)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 17
ID5SL-R* Insight 5-Deck Merchandiser for Dairy and Deli Applications Standard Front-to-Back Depth, Low Front, Rear Sliding Doors
See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.
COOLER
1 1/4(32)
43 7/8(1114)
35 5/8(905)
15 1/2(394)
19 1/2(495)
59 1/4 (1505)
54 5/8(1387)
43 5/8(1108)
9 1/4(235)
ID5SL-R
30 1/8 (765)
84(2134)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
18
ID5SM* Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Medium Front
See Plan View (page 53)Available in 4’, 6’, 8’ and 12’ lengths.
43 7/8(1114)
35 5/8(905)
19(483)
23(584)
59 1/4 (1505)
51 1/8(1299)
43 5/8(1108)
9 1/4(235)
ID5SM
30 1/8 (765)
84(2134)
LOAD
LIM
IT L
INE
* Optional glass front available on this model. See page 1 for drawing and dimensions.
Gross Refrigerated Volume* – 11.7 ft3/ ft (1.09 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 19
COOLER
1 1/4(32)
43 7/8(1114)
35 5/8(905)
59 1/4 (1505)
51 1/8(1299)
43 5/8(1108)
9 1/4(235)
ID5SM-R
30 1/8 (765)
84(2134)
23(584) 19
(483)
LOAD
LIM
IT L
INE
ID5SM-R* Insight 5-Deck Merchandiser for Dairy and Deli Applications Standard Front-to-Back Depth, Medium Front, Rear Sliding Doors
See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 11.7 ft3/ ft (1.08 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
20
ID5SU Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Ultra Low Front
84 7/8(2156)
43 1/2(1105)
35 1/2(902)
11 1/8(283)
14 1/2(368)
29 7/8 (759)
64 3/8 (1635)
60 1/2(1537)
9 1/4(235)
43 7/8(1114)
ID5SU
LOAD
LIM
IT L
INE
See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 21
ID5SV Insight 5-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Very Low Front
88 1/4(2242)
43 1/2(1105)
35 1/2(902)
17 1/4(438)
30(762)
64 1/2 (1638)
43 7/8(1114)
ID5SV
13 7/8(352)
9 1/4(235)
60 1/2(1537)
LOAD
LIM
IT L
INE
See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
22
IDD5NL Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Narrow Front-to-Back Depth, Low Front
See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.
22 1/2(572)
21 1/2(546) 15 1/2
(394)
25 1/4 (641)
59 1/4 (1505)
DoorOpening
51 1/2(1308)
10 1/2(267)
IDD5NL
38 5/8(981)
30 5/8(778)
84(2134)
39(991)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 23
IDD5SL Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVsion Glass Doors, Standard Front-to-Back Depth, Low Front
See Plan View (page 57)Available in 4’, 6’, 8’ and 12’ lengths.
43 7/8(1114)
35 5/8(905)
15 1/2(394)
21 1/2(546)
30 1/8 (765)
59 1/4 (1505)
43 5/8(1108)
10 1/2(267)
DoorOpening
53(1346)
22 1/2(572)
IDD5SL
84(2134)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
24
IDD5SL-R Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Low Front, Rear Sliding Doors
See Plan View (page 57)Available in 4’, 6’, 8’ and 12’ lengths.
COOLER
43 7/8(1114)
35 5/8(905)
15 1/2(394)
21 1/2(546)
30 1/8 (765)
59 1/4 (1505)
43 5/8(1108)
10 1/2(267)
DoorOpening
53(1346)
22 1/2(572)
IDD5SL-R
1 1/4(32)
84(2134)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 11.5 ft3/ ft (1.07 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 25
IDD5SU Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front
See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.
84 7/8(2156)
43 1/2(1105)
35 1/2(902)22 5/8
(575)
15 3/8(391)
29 7/8 (759)
64 3/8 (1635)
DoorOpening
58 3/8(1483)
10 1/2(267)
43 7/8(1114)
IDD5SU
11 1/8(283)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
26
IDD5SV Insight 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Very Low Front
See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.
88 1/4(2242)
43 1/2(1105)
35 1/2(902)22 5/8
(575)
17 7/8(454)
29 7/8 (759)
64 3/8 (1635)
DoorOpening
58 3/8(1483)
43 7/8(1114)
IDD5SV
13 7/8(352)
10 3/4(273)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 27
ID6NL* Insight 6-Deck Merchandiser for Dairy and Deli ApplicationsNarrow Front-to-Back Depth, Low Front
See Plan View (page 54)Available in 4’, 6’, 8’ and 12’ lengths.
39(991)
19 1/2(495) 15 1/2
(394)
89 5/8(2276)
25 1/4 (641)
64 7/8 (1648)
60 1/4(1530)
9 1/4(235)
ID6NL
30 5/8(778)
38 5/8(981)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 10.4 ft3/ ft (0.97 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
28
ID6SU Insight 6-Deck Merchandiser for Dairy and Deli ApplicationsStandard Front-to-Back Depth, Ultra Low Front
See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.
90 7/8(2308)
43 1/2(1105)
35 1/2(902)
14 1/2(368)
70 3/8 (1788)
66 1/2(1689)
9 1/4(235)
43 7/8(1114)
ID6SU
29 7/8 (759)
11 1/8(283)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 29
ID6SU-R Insight 6-Deck Merchandiser for Dairy and Deli Applications Extra Tall, Standard Front-to-Back Depth, Ultra Low Front, Rear Sliding Doors
See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.
COOLER
1 1/4(32)
43 1/2(1105)
35 1/2(902)
14 1/2(368)
70 3/8 (1788)
66 1/2(1689)
9 1/4(235)
43 7/8(1114)
ID6SU-R
29 7/8 (759)
11 1/8(283)
90 7/8(2308)LO
AD L
IMIT
LIN
E
Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
30
ID6SV Insight 6-Deck Merchandiser for Dairy and Deli ApplicationsExtra Tall, Standard Front-to-Back Depth, Very Low Front Lip
See Plan View (page 55)Available in 4’, 6’, 8’ and 12’ lengths.
43 1/2(1105)
35 1/2(902)
66 3/8 (1686)
62 5/8(1591)
9 1/4(235)
43 7/8(1114)
ID6SV
17 1/4(438) 13 7/8
(352)
29 7/8 (759)
89 5/8(2276)LO
AD L
IMIT
LIN
E
Gross Refrigerated Volume* – 12.7 ft3/ ft (1.18 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 31
22 1/2(572)
39(991)
21 1/2(546)
89 5/8(2276)
25 1/4 (641)
64 7/8 (1648)
10 1/2(267)
IDD6NL
DoorOpening
57 1/4(1454)
15 1/2(394)
38 5/8(981)
30 5/8(778)
LOAD
LIM
IT L
INE
IDD6NL Insight 6-Deck Merchandiser for Dairy and Deli Applicationswith EcoVision Glass Doors, Narrow Front-to-Back Depth, Low Front
See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 10.4 ft3/ ft (0.97 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
32
IDD6SU Insight 6-Deck Merchandiser for Dairy and Deli Applicationswith EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front
See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
43 7/8(1114)
15 3/8(391)
10 1/2(267)
DoorOpening64 1/4(1632)
IDD6SU
11 1/8(283)
22 5/8(575)
29 7/8 (759)
90 7/8(2308)
43 1/2(1105)
35 1/2(902)
70 3/8 (1788)
Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 33
IDD6SU-R Insight 6-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front, Rear Sliding Doors
See Plan View (page 56)Available in 4’, 6’, 8’ and 12’ lengths.
COOLER
LOAD
LIM
IT L
INE
43 7/8(1114)
15 3/8(391)
10 1/2(267)
DoorOpening64 1/4(1632)
IDD6SU-R
11 1/8(283)
22 5/8(575)
29 7/8 (759)
43 1/2(1105)
35 1/2(902)
70 3/8 (1788)
1 1/4(32)
90 7/8(2308)
Gross Refrigerated Volume* – 13.2 ft3/ ft (1.23 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
34
IDD6SV Insight 6-Deck Merchandiser for Dairy and Deli Applicationswith EcoVision Glass Doors, Standard Front-to-Back Depth, Very Low Front
See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.
90 1/4(2292)
43 1/2(1105)
35 1/2(902)22 5/8
(575)
17 7/8(454)
29 7/8 (759)
66 3/8 (1686)
DoorOpening
58 1/2(1486)
IDD6SV
13 7/8(352)
12 3/4(324)
43 7/8(1114)
10 3/4(273)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 12.4 ft3/ ft (1.15 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 35
IDF5NM* Insight 5-Deck Freedom Line Merchandiser for Dairy ApplicationsNarrow Front-to-Back Depth, Medium Front
LOAD
LIM
IT L
INE
19(483)
23(584)
51 1/2(1308)
59 1/4(1505)
25 1/4(641)
20 1/8(511)
29 1/4(743)
38 3/4(984)
84(2133)
103 1/2(2629)
IDF5NM
38 5/8(981)
31 5/8(803)
1/2(13)
See Plan View (page 58)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 9.6 ft3/ ft (0.89 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
36
IDF5SM* Insight 5-Deck Freedom Line Merchandiser for Dairy ApplicationsStandard Front-to-Back Depth, Medium Front
LOAD
LIM
IT L
INE
59 1/4(1505)
30 1/8(765)
43 5/8(1108)
IDF5SM
1/2(13)
35 5/8(905)
43 5/8(1108)
19(483)
51 3/8(1305)
20 1/8(511)
29 1/4(743)
23(584)
84(2133)
103 1/2(2629)
See Plan View (page 59)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 11.7 ft3/ ft (1.09 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 37
IDDF5SU Insight Freedom Line 5-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Ultra Low Front
See Plan View (page 59)Available in 4’, 6’, 8’ and 12’ lengths.
15 1/4(387)
31(787)
11 1/8(283)
104 1/2(2654)
44 3/8(1127)
36 3/4(933)
1 1/8(29)
64 3/8(1635)
84 7/8(2156)
29 7/8(759)
20 1/4(514)
44 5/8(1133)
IDDF5SU
DoorOpening58 1/4(1480)
22 5/8(575)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 12.1 ft3/ ft (1.12 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
38
IDDF6SV Insight Freedom Line 6-Deck Merchandiser for Dairy and Deli Applications with EcoVision Glass Doors, Standard Front-to-Back Depth, Very Low Front
See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.
90 1/4(2292)
43 1/2(1105)
35 1/2(902)22 5/8
(575)
17 7/8(454)
29 7/8 (759)
66 3/8 (1686)
DoorOpening
58 1/2(1486)
IDDF6SV
13 7/8(352)
12 3/4(324)
43 5/8(1108)
20 1/4(514)
109 1/4(2775)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 12.4 ft3/ ft (1.15 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 39
IM1SL* Insight Single-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD LIMIT LINE
IM1SL
8 5/8(219)
42 1/8(1070)
26 1/8(664)
30 1/8(765)
35 5/8(905)
43 5/8(1108)
30 7/8(784)
30 1/8(765)
Gross Refrigerated Volume* – 1.7 ft3/ ft (0.16 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
40
IM1SM* Insight Single-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Medium Front
See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD LIMIT LINE
IM1SM
8 5/8(219)
29 1/2(749)
30 1/8(765)
38 1/8(968)
25 3/4(654)
29 5/8(752)
35 5/8(905)
43 5/8(1108)
Gross Refrigerated Volume* – 1.7 ft3/ ft (0.158 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 41
* Optional glass front available on this model. See page 1 for drawing and dimensions.
IM3SL
30 1/8(765)
9 1/4(235)
36 1/8(918)
40 1/2(1029)
36 1/2(927)
30 1/8(765)
26 1/4(667)
75 3/4(1924)
35 5/8(905)
43 5/8(1108)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 7.0 ft3/ ft (0.65 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
IM3SL* Insight 3-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.
42
IM4SL* Insight 4-Deck Merchandiser for Meat ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
IM4SL
36 1/2(927)
26 1/8(664)
22 1/4(565)
75 7/8(1927)
30 1/8(765)
9 1/4(235)
40 1/8(1019)
44 1/2(1130)
35 5/8(905)
43 5/8(1108)
Gross Refrigerated Volume* – 7.7 ft3/ ft (0.72 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 43
IM5NL* Insight 5-Deck Merchandiser for High Volume Meat ApplicationsNarrow Front-to-Back Depth, Low Front
See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
30 5/8(778)
36 1/2(927)
22 3/4(578) 18 7/8
(479)
25 1/4(641)
9 1/4(235)
47 3/8(1203)
52(1321)
IM5NL
79 7/8(2028)
38 5/8(981)
Gross Refrigerated Volume* – 7.85 ft3/ ft (0.73 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
44
IM5SL* Insight 5-Deck Merchandiser for High Volume Meat ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
36 1/2(927)
22 3/4(578) 18 3/4
(476)
79 7/8(2028)30 1/8
(765)
47 1/4(1200)
51 7/8(1318)
IM5SL
9 1/4(235)
35 5/8(905)
43 5/8(1108)
Gross Refrigerated Volume* – 8.9 ft3/ ft (0.83 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
* Optional glass front available on this model. See page 1 for drawing and dimensions.
INSIGHT PRODUCT REFERENCE GUIDE 45
IP1SL Insight Single-Deck Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 1.67 ft3/ ft (0.16 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
LOAD LIMIT LINE
IP1SL
8 5/8(219)
30 1/8(765)
42 1/8(1070)
26 1/4(667)
30 1/8(765)
35 5/8(905)
43 5/8(1108)
30 3/4(781)
46
IP1XSL Insight Single-Deck Extra Tall Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 2.34 ft3/ ft (0.22 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
LOAD LIMIT LINE
IP1XSL
8 5/8(219)
30 1/8(765)
48 5/8(1235)
26 1/4(667)
30 1/8(765)
35 5/8(905)
43 5/8(1108)
32 7/8(835)
INSIGHT PRODUCT REFERENCE GUIDE 47
IP1XXSL Insight Single-Deck Extra-Extra Tall Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 60)Available in 4’, 6’, 8’ and 12’ lengths.
Gross Refrigerated Volume* – 2.77 ft3/ ft (0.26 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
LOAD LIMIT LINE
IP1XXSL
8 5/8(219)
30 1/8(765)
52 5/8(1337)
26 1/4(667)
30 1/8(765)
35 5/8(905)
43 5/8(1108)
34 5/8(879)
48
LOAD
LIM
IT L
INE
35 5/8(905)
36 1/2(927)
43 5/8(1108)
30 1/8(765)
26 1/8(664)
75 3/4(1924)
30 1/8(765)
9 1/4(235)
36 1/8(918)
40 1/2(1029)
IP2SL
Gross Refrigerated Volume* – 7.0 ft3/ ft (0.65 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
IP2SL Insight 2-Deck Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.
INSIGHT PRODUCT REFERENCE GUIDE 49
IP4NL Insight 4-Deck Merchandiser for Produce ApplicationsNarrow Front-to-Back Depth, Low Front
See Plan View (page 62)Available in 4’, 6’, 8’ and 12’ lengths.
IP4NL
22 1/8(562)
26 1/8(664)
52(1321)
47 3/8(1203)
9 1/4(235)
25 1/4(641)
83 1/4(2115)
38 5/8(981)
36 1/2(927)
30 5/8(778)
LOAD
LIM
IT L
INE
Gross Refrigerated Volume* – 7.85 ft3/ ft (0.73 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
50
IP4SL Insight 4-Deck Merchandiser for Produce ApplicationsStandard Front-to-Back Depth, Low Front
See Plan View (page 61)Available in 4’, 6’, 8’ and 12’ lengths.
LOAD
LIM
IT L
INE
35 5/8(905)
36 1/2(927)
43 5/8(1108)
26 1/8(664)
22 1/8(562)
79 7/8(2028)
30 1/8(765)
9 1/4(235)
47 1/4(1200) 51 7/8
(1318)
IP4SL
Gross Refrigerated Volume* – 8.9 ft3/ ft (0.83 m3/ m)
*per ANSI/AHRI 1200-2013 appendix C. Volume Calculation
INSIGHT PRODUCT REFERENCE GUIDE 51
Plan View IC2SL and IC2SM
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
SplashguardRefrigeration OutletField ElectricalConnectionat BOTTOMof Case
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
7(178)
7(178)
3 5/8(92)
36 3/8(924)
21 7/8(556)
44 3/8(1127)
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
Plan View IC2NL and IC2XNL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutletWireway in Canopy
WasteOutlet
Splashguard
Field ElectricalConnectionat BOTTOMof Case
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
7(178)
7(178)
3 5/8(92)
31 1/2(800)
21 7/8(556)
39 1/2(1003)
52
Plan View IC2XSL, IC2XSM, and IC3SL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
SplashguardRefrigeration OutletField ElectricalConnectionat BOTTOMof Case
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
7(178)
7(178)
3 5/8(92)
36 3/8(924)
23 3/8(594)
44 3/8(1127)
Plan View IC3BL
Refrigeration OutletRefrigeration
Outlet
Field ElectricalConnectionat BOTTOMof Case
Splashguard
Waste Outlet
Wireway in Canopy
7(178)
7(178)
48 1/4(1226)
40 1/4(1022)
25 3/8(645)
A
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
FRONT
1 1/2 Inch(38 mm)RequiredAir Gap
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
53INSIGHT PRODUCT REFERENCE GUIDE
Plan View IC4SL, IC6SL, IC6SM, ID5SL, and ID5SM
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
1 1/2 Inch(38 mm)RequiredAir Gap
Refrigeration Outlet
RefrigerationOutlet
Waste Outlet
Wireway in CanopySplashguard
FRONT
3 5/8(92)
7(178)
7(178)
A
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
35 5/8(905)
43 5/8(1108)
43 7/8(1114)
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Field ElectricalConnectionat TOPof Case
Plan View IC4BM
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
7(178)
7(178)
47 1/2(1207)
39 1/2(1003)
A
FRONT
RefrigerationOutlet
RefrigerationOutletField
ElectricalConnection
at TOPof Case
Splashguard
Waste Outlet
1 1/2 Inch(38 mm)RequiredAir Gap
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
54
Plan View ID5SL-R and ID5SM-R
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
COOLER
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
FRONT
7 (178) 7 (178) 3 5/8 (92) A
35 5/8(905)
43 5/8(1108)
43 7/8(1114)
Field ElectricalConnectionat TOPof Case
Plan View ID5NL, ID5NM, and ID6NL
1 1/2 Inch(38 mm)RequiredAir Gap
RefrigerationShroud
Wireway in Canopy
WasteOutlet
Splashguard
FRONT
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
A
30 5/8(778)
39(991)
38 5/8(981)
7(178)
7(178)
3 5/8(92)
Field ElectricalConnectionat TOPof Case
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
INSIGHT PRODUCT REFERENCE GUIDE 55
Plan View ID5SU and ID5SV
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
Plan View ID6SU and ID6SV
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
43 1/2(1105)
35 1/2(902)
43 7/8(1114)
1 1/2 Inch(38 mm)RequiredAir Gap
7(178)
7(178)
3 5/8(92)
Field ElectricalConnectionat TOPof Case
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
43 1/2(1105)
35 1/2(902)
43 7/8(1114)
1 1/2 Inch(38 mm)RequiredAir Gap
7(178)
7(178)
3 5/8(92)
Field ElectricalConnectionat TOPof Case
56
Plan View ID6SU-R and IDD6SU-R
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
COOLER
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
FRONT
7 (178) 7 (178) 3 5/8 (92) A
35 1/2(902)
81/2(216)
43 1/2(1105)
43 7/8(1114)
Field ElectricalConnectionat TOPof Case
Plan View IDD5NL and IDD6NL
RefrigerationShroud
Wireway in Canopy
WasteOutlet
Splashguard
Door Swing Clearance
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
7(178)
7(178)
3 5/8(92)
38 5/8(981)
30 5/8(778)
39(991)
22 1/2(572)
Field ElectricalConnectionat TOPof Case
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
INSIGHT PRODUCT REFERENCE GUIDE 57
Plan View IDD5SL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
Door Swing Clearance
7(178)
7(178)
3 5/8(92)
43 5/8(1108)
35 5/8(905)
43 7/8(1114)
22 1/2(572)
Field ElectricalConnectionat TOPof Case
COOLER
43 5/8(1108)
35 5/8(905)
43 7/8(1114)
22 1/2(572)
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
RefrigerationOutlet
Splashguard
Door Swing Clearance
WasteOutlet
RefrigerationOutlet
Wireway in Canopy
FRONT
A7 (178) 7 (178) 3 5/8 (92)
Field ElectricalConnectionat TOPof Case
Plan View IDD5SL-R
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
58
Plan View IDD5SU, IDD5SV, IDD6SU, and IDD6SV
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
Door Swing Clearance
43 1/2(1105)
35 1/2(902)
43 7/8(1114)
22 5/8(575)
7(178)
7(178)
3 5/8(92)
Field ElectricalConnectionat TOPof Case
Plan View IDF5NM
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
Splashguard
Waste OutletRefrigerationShroud
Wireway in Canopy
38 3/4(984)
38 5/8(981)
31 5/8(803)
3 1/2(89)
7(178)
7(178)
3 5/8(92)
1 1/2 Inch(38 mm)RequiredAir Gap
A
FRONT
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
Field ElectricalConnectionat TOPof Case
59INSIGHT PRODUCT REFERENCE GUIDE
Plan View IDDF5SU
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
Wireway in Canopy
WasteOutlet
Splashguard
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 1/2 (3670)
Door Swing Clearance
7(178)
7(178)
3 5/8(92)
44 3/8(1127)
36 3/4(933)
44 5/8(1133)
22 5/8(575)
Field ElectricalConnectionat TOPof Case
Plan View IDF5SM
1 1/2 Inch(38 mm)RequiredAir Gap
Refrigeration Outlet
RefrigerationOutlet
Waste Outlet
Wireway in CanopySplashguard
FRONT
3 5/8(92)
7(178)
7(178)
A
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
35 5/8(905)
43 5/8(1108)
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Field ElectricalConnectionat TOPof Case
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
60
Plan View IM1SL, IM1SM, IP1SL, IP1XSL, and IP1XXSL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
7(178)
7(178)
3 5/8(92)
43 5/8(1108)
35 5/8(905)
RefrigerationOutlet
RefrigerationOutlet Waste
Outlet
Splashguard
Field ElectricalConnectionat BOTTOMof Case
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Plan View IDDF6SV
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutlet
RefrigerationOutlet
Wireway in Canopy
WasteOutlet
Splashguard
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
Door Swing Clearance
43 1/2(1105)
35 1/2(902)
43 7/8(1114)
22 5/8(575)
7(178)
7(178)
3 5/8(92)
Field ElectricalConnectionat TOPof Case
INSIGHT PRODUCT REFERENCE GUIDE 61
Plan View IM3SL, IM4SL, IM5SL, IP2SL, and IP4SL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
RefrigerationOutletWaste
Outlet
Splashguard
1 1/2 Inch(38 mm)RequiredAir Gap
FRONT
A
Notes: Overall case length without ends or partitions. Contact your sales representative for information on possible availability of additional case lengths.
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
Wireway in Canopy
RefrigerationOutlet
Field ElectricalConnectionat TOPof Case
7(178)
7(178)
3 5/8(92)
36 1/2(927)
35 5/8(905)
43 5/8(1108)
Plan View IM5NL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
1 1/2 Inch(38 mm)RequiredAir Gap
RefrigerationShroud
Wireway in Canopy
WasteOutlet
Splashguard
FRONT
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
A
30 5/8(778)
38 5/8(981)
7(178)
7(178)
3 5/8(92)
31/2(89)Field Electrical
Connectionat TOPof Case
62
Plan View IP4NL
Notes:Overall case length without ends or partitions. Each standard end and each insulated partition adds 1-1/2 in. (38 mm) to case line up. Optional view end with end bumper adds 3-3/4 in. (95 mm).
1 1/2 Inch(38 mm)RequiredAir Gap
RefrigerationShroud
Wireway in Canopy
WasteOutlet
Splashguard
FRONT
Dimensions 4 FT 6 FT 8 FT 12 FT
A 48 1/8 (1222) 72 1/4 (1835) 96 1/4 (2445) 144 3/8 (3668)
A
30 5/8(778)
38 5/8(981)
7(178)
7(178)
3 5/8(92)
31/2(89)Field Electrical
Connectionat TOPof Case
INSIGHT PRODUCT REFERENCE GUIDE 63
Notes
6464
Notes
IM MerchandisersPages 39 - 44
IDD5 MerchandisersPages 22 - 26
IC Merchandisers Pages 2 - 13
ID5 Merchandisers Pages 14 - 21
ID6 Merchandisers Pages 27 - 30
IDD6 Merchandisers Page 31 - 34
IP MerchandisersPages 45 - 50
ID Freedom Line MerchandisersPages 35 - 38
Hussmann Corporation 12999 St. Charles Rock Rd.Bridgeton, MO 63044-2483Ph: 314.291.2000
www.hussmann.com
Printed in U.S.A. ©2017 Hussmann CorporationInsight_PRG_052617