10

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV

Up to 36 kV - 630 A

440TBINTERFACE C

TEE CONNECTOR

Technical characteristics• The thick conductive EPDM

jacket provides a total safe totouch screen which ensuressafety for personnel.

• Each separable connector istested for AC withstand andpartial discharge prior toleaving the factory.

ApplicationSeparable tee shapeconnector (bolted type)designed to connect polymericinsulated cable to equipment(transformers, switch gear,motors, ...).Also connects cable to cablewhen using the appropriatemating parts.

DesignSeparable connectorcomprising:

1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer

moulded between the insertand the jacket.

4. Type C - 630 A interfaceas described by CENELECEN 50180 and 50181.

5. Conductor connector.6. Basic insulating plug (with

VD point).7. Cable reducer.8. Conductive rubber cap.9. Clamping screw.

10. Earthing lead.

The screen break designenables cable outer sheathtesting without removing ordismantling the connector.

Specifications andstandardsThe separable connector 440TBmeets the requirements ofCENELEC HD 629.1.

Separableconnector

type

VoltageUm(kV)

CurrentIr

(A)

Conductor size (mm2)

min. max.440TB/GK440TB/GM400TB/G

122436

630630630

185185185

630630630

400 mm

3

2

1

4

5

7

6 8

10

9

255 mm220 mm

michael ryan
New Logo

11

Kit contentsThe complete (K)(M)440TB/Gtee connector kit comprises thefollowing components:

The kit also comprises lubricant, wipers,installation instructions and crimp chart.

Ordering instructionsTo order the tee connector,select the ordering part numberwhich gives you the bestcentring of your core insula-tion diameter and substitute Xusing table X, according to yourconductor size and type.Add a 'K' for use up to 24 kVand add an 'M' for use up to36 kV.

Orderingpart number

Dia. over core insulation (mm)

min. max.

440TB/G-22-X440TB/G-27-X440TB/G-32-X440TB/G-37-X440TB/G-43-X

23.528.534.039.045.5

31.037.542.548.556.0

Example:The copper wire screened cableis 36 kV, 240 mm2 strandedaluminium with a diameter overcore insulation of 37.0 mm.Order a M440TB/G-32-240(K)M-12-2 tee connector kit.

When installed on anappropriate equipment

bushing:1250 A continuously

For use withcopper tape

screened cables.Order: Kit MT.

+ + +

Connector housing(K)(M)440BT/G

Clampingscrew

400TCS

ConductorcontactTBC-X

Basicinsulating

plug +rubber cap

(K)(M)400BIPA

+

Cable reducer611CA-W

= (K)(M)440TB/G-W-Xconnector kit

Table W

Table X

Conductor size(mm2)

Aluminium conductor Copper conductor

DINhexagonal

Deepindent

DINhexagonal

185240300400500630

185(K)M-12-2240(K)M-12-2300(K)M-12-2400(K)M-12-2500(K)M-12-2

185KM-12-1240KM-12-1300KM-12-1400KM-12-1500KM-12-1630KM-12-1

185(K)M-11-2240(K)M-11-2300(K)M-11-2400(K)M-11-2500(K)M-11-2630(K)M-11-2

For use withother cable types.

Please contact ourrepresentative.

For outdoorapplications.

Order: +MWS.

Components can beordered individually.

For use in potentiallyexplosive atmospheres

(for 12 kV max.).Order: -/ATEX.