Page 1 / 4www.baumer.com

Temperature Sensor TE2Compact RTD temperature sensors

EN

/201

4-03

-27

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Data sheet B12.05 TE2

Main features

Applications

�� Compact and light weight�� Available with 4...20 mA transmitter or Pt100 output�� Available with hygienic as well as industrial process connections�� Programmable by FlexProgrammer 9701

�� Food & Beverage�� Laboratory & Medical�� Oil & Gas / Chemical�� Water & Waste water

�� Energy�� Transportation & Logistics

Technical specificationHousing Compact Ø 18mm

Stainless steel AISI 304 (1.4301)

El. connection M12 or DIN 43650 plugOutput Pt100 or 4...20mASensor tube material Stainless steel AISI 316L (1.4404)

PEEK

Sensor diameter outside Ø 6mmSensor length < 3 000 mmStandard response tipFast response tip

Ø 6, Ø 4 or Ø 3

Time constant τ0.5

Sensor tip Ø 6mmSensor tip Ø 4mmSensor tip Ø 3mmConical sensor

In water 3.0 sec.In water 2.5 sec.In water 1.3 sec.In water <1.0 sec.

EnvironmentAmbient temperature Pt100 output -40...125°C

w. transmitter -40...85°C

Process temperature -50...250°CProtection class M12 : IP67 / DIN 43650 : IP65Humidity <100% RH, condensingVibrations GL, test 2

Sensor element, Pt100 DIN/EN/IEC 60751Pt100 DIN class BPt100 1/3 DIN class BPt100 1/6 DIN class BPt100 DIN class A

± (0.3 + 0.005 × t) °C± 1/3 x (0.3 + 0.005 × t) °C± 1/6 x (0.3 + 0.005 × t) °C± (0.15 + 0.002 × t) °C

Single elementDouble element

1 × Pt1002 × Pt100

Connection 4-wire, 2 × 2 wire

Temperature curve

°C 300

250

with cooling neck

200

without cooling neck

150

100

50

0 0 20 40 60 80 100 °C

85°C

85°C

Process

Ambient

Page 2 / 4www.baumer.com Data sheet B12.05 TE2

EN

/201

4-03

-27

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Temperature Sensor TE2Compact RTD temperature sensors

Dimensions (mm) and constructions details

50

Ø 18

26

50

42

70

46

AF 22

G1/2A

Ø6

L

L

Ø6

27

AF 17

M12x1.5

L

Ø6

8 Ø18

24.5

AF 22

Ø6

L

L

G1/2A

20

Ø6

AF 22

G1/4DIN 3852-E

21 22

L L

Ø6 Ø6

58/6

3L2

0/L2

5

Ø3

326 Ø3

PEEK

AF17

M12x1.5

2032

L Ø6

G½A HygienicCode 4

M12x1.5Code 5

Without threadCode 1

G½A, ISO 228/1Code 3

G¼A DIN 3852-ECode 8

ISO 2852 DN 38Code 9

Triclamp®

Code AConical sensor-Code 7

M12x1.5 coneCode 6

3A DN 38Code B

StandardTip

Fastresponse tip

Ø6 Ø6Ø3 or Ø4 mm

Plug M12 Plug M12with transmit.

PlugDIN 43650-A

PlugDIN 43650-Awith transmit.

Cooling neck

Page 3 / 4www.baumer.com Data sheet B12.05 TE2

EN

/201

4-03

-27

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Temperature Sensor TE2Compact RTD temperature sensors

Electrical connections

InputAccuracy < 0.25°C (@ ≤ 100°C)Sample time < 0.7 sec.Pt100 standard IEC/DIN/EN 60 751-2RTD measuring current 0.3 mA, continuouslyError detection delay < 10 sec.Measuring unit °C or °FMinimum span 25°CProtection ± 35 VDCSurpression 50 and 60 HzResolution 14 bitRepeatability < 0.1°CRipple immunity IEC 770 6.2.4.2Offset adjustment Max. ± 10°CIsolation, sensor to case 50 VAC (test 500V)

Plug DIN 43650-A M12 Plug

Transmitter

Other dataTemperature drift Typ. 0.003% per °C

Max. 0.01% per °C

Power-on time 20 sec.

OutputSignal span 4...20 mA, 2-wireAccuracy < 0.1% of signal spanSupply range 8...35 VDCRipple immunity 3 VmsLoad equation RL ≤ (VDC -8)/23 [kOhm]Up/Down scaling limits 23 mA/3.5 mADamping 0...30 sec.Protection Reserved polarity protectionResolution 12 bitEffect of variations in supply voltageOutput current 0.01% per volt

Environmental conditionsOperating temperature -40...85°CStorage temperature -55...90°CLong-term test IEC 770 6.3.2

EMC dataGeneric standards EN 61000-6-3, EN 61000-6-2Product standard EN 61326Namur NE21

Page 4 / 4www.baumer.com Data sheet B12.05 TE2

EN

/201

4-03

-27

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Temperature Sensor TE2Compact RTD temperature sensors

Ordering details TE2

TE2 – x . x . x x x x . xxxx . xModelCompact temperature sensor TE2

Sensor tip

Not specified For connection code 6 & 7 0Standard Normal response 1Fast Fast response Ø4 mm Sensor length 35...300 mm 2Fast Fast response Ø3 mm Sensor length 35...300 mm 3

.Process connection

Tube without connection PN40 1Nipple, male G½ ISO 228/1 PN100 3Nipple, male G½ hygienic ISO 228/1 PN40 4Nipple, male M12 x 1.5 hygienic ISO 228/1 PN40 5Nipple, male M12 x 1.5 hygienic ISO 228/1 PEEK cone Ø3 x 5 mm tip PN40 6G⅛″ union nut Conical sensor Ø3 x 20 mm or 25 mm sensor tip PN40 7Nipple, male G¼″ DIN 3852-E PN100 8DN25/DN38 clamp (1″, 1½″) ISO 2852 PN40 9Triclamp® ½″, ¾″ (DN15/DN20) PN40 A3A/DN38 Hygienic connection PN40 B

.Sensor element1 x Pt100 CI. B 12 x Pt100 CI. B For 6 mm standard tip only 21 x Pt100 CI. 1/3 B 32 x Pt100 CI. 1/3 B For 6 mm standard tip only 41 x Pt100 CI. 1/6 B 51 x Pt100 CI. A 72 x Pt100 CI. A For 6 mm standard tip only 8Cooling neckNone 0Cooling neck See table page 1 4

Electrical connectionM12 plug, 4 pole 1M12 plug, 4 pole with 4...20 mA transmitter 1 x Pt100 only 2DIN 43650-A 4DIN 43650-A with 4...20 mA transmitter 1 x Pt100 only 5CertificatesNot specified 0

.Sensor tube length5 mm for connection code 6 000520 mm for connection code 7 002025 mm for connection code 7 0025Length in mm (e.g. 60 mm = 0060) xxxx

.ConfigurationNo configuration 0Configuration of range C