change over
Post on 01-Nov-2014
74 Views
Preview:
DESCRIPTION
TRANSCRIPT
A. 112 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
FunctionsSIRCOVER products are manuallyoperated multipolar changeover switches.They ensure switching, transfer of sourcesor transfer of two low voltage circuits onload as well as their safety disconnection.
SIRCOVER By-Pass are manuallyoperated changeover switches.They are a combination of threeinterlocked switches enabling the use with3 + 6 pole or 4 + 8 pole.They insulate by providing simultaneoussafety isolation top and bottom and bypassing loads or low voltage circuitsmainly during maintenance operations.
Conformity to standards• IEC 60947-3• EN 60947-3• VDE 0660 Part 107 (1992) • NBN EN 60947-3• BS EN 60947-3
Approvals and certifications(1)
• Bureau Véritas• BBJ Poland (attestation of verification)
(1) In progress for certain ratings.
General characteristics• 3 stable positions (I, 0, II) or overlapping
contacts on request (I, I + II, II) , and onload changeover switching (AC-22 andAC-23)
• Fully visible breaking• IP20 device and accessories.
Available on request• Devices 6 or 8 pole• Devices with overlapping (make before
break) contacts (I, I+II, I) • Devices with over-sized neutral e.g.:
3 x 250 A + N 400 A• Devices with advanced neutral.
�
FunctionsReferencesAccessoriesCharacteristicsDimensions
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
svr_
107_
a_1_
cat
svr_
125_
a_1_
cat
SIRCOVER 3 pole
SIRCOVER by-pass 4 pole
A. 113
Changeover switches
SIRCOVER and SIRCOVER by-pass
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
svr_
103_
a_1_
x_ca
t
SIRCOVER by-pass (I,0,II)
Break before make application.
• SIRCOVER by-pass 125 to 1 600 A
Typical application
�
1
2
3
4
5
6
7
Overview (for further details, please see theinstallation instructions supplied with eachdevice).
1. Direct front operation.
2. External front operation.
3 et 4. Auxiliary contacts.
5. Bridging bar.
6. Terminal shrouds.
7. Inter phase barrier.
• SIRCOVER 125 to 3 150 A
SIRCOVER by-pass with overlapping contacts (on request)
Make before break application.
Charge Charge Charge
I
I
I
II
I
O
I
I
II
I
IIIII
I
II
I
I
II
I
I
II
I IIO
I IIO
I IIO
atys
_570
_a_1
_x_c
at
I
I
II
I
I
II
I
I
II
I III+II
I III+II
I III+II
atys
_571
_a_1
_x_c
at
Illustrations
4109 1002
Switches
A. 114 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
� FunctionsReferencesAccessoriesCharacteristicsDimensions
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
References
svr_
112_
a_1_
cat
125 A 160 A 200 A 250 AFront operation changeover switch (switch body only) - SIRCOVERNo. of poles Changeover operation type References References References References
3 pole I - 0 - II 4100 3013 4100 3016 4100 3019 4100 30254 pole I - 0 - II 4100 4013 4100 4016 4100 4019 4100 40253 pole I - I+II - II 4190 3013 4190 3016 4190 3019 4190 30254 pole I - I+II - II 4190 4013 4190 4016 4190 4019 4190 4025
Front operation changeover switch (switch body only) - SIRCOVER by-pass
3 + 6 pole I - 0 - II 4100 7013 4100 7016 4100 7019 4100 70254 + 8 pole I - 0 - II 4100 9013 4100 9016 4100 9019 4100 9025
AccessoriesDirect operation handle
Black SIRCOVER 4199 5012 4199 5012 4199 5012 4199 5012Black SIRCOVER by-pass 4199 5012 4199 5012 4199 5012 2799 7052
External operation handle
I - 0 - II IP55 1421 2113 1421 2113 1421 2113 1421 2113I - 0 - II IP65 1423 2113 1423 2113 1423 2113 1423 2113
SIRCOVERSIRCOVER
I - 0 - II IP55 1421 2113 1421 2113 1421 2113 -I - 0 - II IP65 1423 2113 1423 2113 1423 2113 1433 3113
SIRCOVER by-passSIRCOVER by-pass
Shaft extension for external operation (for dimensions see “Accessories” pages)
200 mm 1400 1020 1400 1020 1400 1020 1400 1020320 mm 1400 1032 1400 1032 1400 1032 1400 1032
SIRCOVERSIRCOVER
200 mm 1400 1020 1400 1020 1400 1020 1401 1520320 mm 1400 1032 1400 1032 1400 1032 1401 1532
SIRCOVER by-passSIRCOVER by-pass
Bridging bars
1 pole 4109 0019 4109 0019 4109 0019 4109 0025
Auxiliary contacts (1 per position)
1st / 2nd AC NO/NC 4109 0021 4109 0021 4109 0021 4109 0021
Terminal shrouds (1 set) (1)(2)
3 pole top / bottom / front(I) / rear (II) 2694 3014 2694 3014 2694 30214 pole top / bottom / front(I) / rear (II) 2694 4014 2694 4014 2694 4021
top / bottomtop / bottom
(1) To shroud front switch top and bottom 2 references required for SIRCOVER and 3 references required for SIRCOVER by-pass.(2) To fully shroud front and rear / top and bottom 4 references required for SIRCOVER and 6 references required for SIRCOVER by-pass.(3) Specific handle included.(4) Lock not included.
Terminal screens (1 per position)
3 pole 1509 3012 1509 3012 1509 3012 1509 30254 pole 1509 4012 1509 4012 1509 4012 1509 4025
Handle key interlocking accessories - For direct front operation
Locking using RONIS EL11AP lock in position O(3)(4) 4109 1006 4109 1006 4109 1006 4109 1006Locking using RONIS EL11AP lock in position I, O, II(3)(4) 4109 1002 4109 1002 4109 1002
Handle key interlocking accessories - For external front operation
Locking using RONIS EL11AP lock in position O(4) 1499 7701 1499 7701 1499 7701 1499 7701Locking using CASTELL type K lock in position O(4) 1499 7702 1499 7702 1499 7702 1499 7702
400 A
References
4100 30394100 40394190 30394190 4039
4100 70394100 9039
4199 50122799 7052
1421 21131423 2113
-1433 3113
I - I+II - II IP65 1423 2114 1423 2114 1423 2114 1423 2114SIRCOVER 1423 2114
1400 10201400 10321401 15201401 1532
4109 0039
4109 0021
2694 30212694 4021
1509 30251509 4025
4109 10064109 1002
1499 77011499 7702
2694 30142694 4014
4109 1002
A. 115This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
Changeover switches
SIRCOVER and SIRCOVER by-pass
SOCOMEC general catalogue
References
SwitchesFront operation changeover switch (switch body only) - SIRCOVERNo. of poles Changeover operation type
3 pole I - 0 - II4 pole I - 0 - II3 pole I - I+II - II4 pole I - I+II - II
Front operation changeover switch (switch body only) - SIRCOVER by-pass
3 + 6 pole I - 0 - II4 + 8 pole I - 0 - II
AccessoriesDirect operation handle
Black
External operation handle
I - 0 - II IP55
I - I+II - II IP65I - 0 - II IP65
I - 0 - II IP65
Shaft extension for external operation (for dimensions see “Accessories” pages)
200 mm320 mm
SIRCOVER
SIRCOVERSIRCOVER
SIRCOVER by-pass
SIRCOVERSIRCOVER
Bridging bars
1 pole
Auxiliary contacts (1 per position)
1st / 2nd AC NO/NC 3/4 poles
Terminal shrouds (1 set) (1)(2)
3 pole top / bottom / front (I) / rear (II)4 pole top / bottom / front (I) / rear (II)
top / bottomtop / bottom
(1) To shroud front switch top and bottom 2 references required for SIRCOVER and 3 references required for SIRCOVER by-pass.(2) To fully shroud front and rear / top and bottom 4 references required for SIRCOVER and 6 references required for SIRCOVER by-pass.(3) Specific handle included.(4) Lock not included.(5) This locking facility can be configured by the user in the 3 positions.
Terminal screens (1 per position)
3 pole4 pole
Handle key interlocking accessories - For direct front operation
Locking using RONIS EL11AP lock in position O(3)(4)
Locking using RONIS EL11AP lock in position I, O, II(3)(4)
Handle key interlocking accessories - For external front operation
Locking using RONIS EL11AP lock in position O(4)
Locking using CASTELL type K lock in position O(4)
DIRECT OPERATION
New handle=
New shaft
EXTERNAL OPERATION
T O O R D E R
+ O T H E R A C C E S S O R I E S
Directhandle
Switchbody
Switchbody
Externalhandle+ Shaft+ +
NEW
SHAFT
NEW
HANDLE
pict
o_08
0_b_
1_gb
svr_
113_
a_1_
cat
500 A 630 A 800 A
References References References
4100 3050 4100 3063 4100 30804100 4050 4100 4063 4100 40804190 3050 4190 3063 4190 30804190 4050 4190 4063 4190 4080
4100 7050 4100 7063 4100 70804100 9050 4100 9063 4100 9080
4199 5012 4199 5012 2799 7052Black
SIRCOVERSIRCOVER by-pass 2799 7052 2799 7052 2799 7012
1421 2113 1421 2113 -
1423 2114 1423 2114 1433 31141423 2113 1423 2113 1433 3113
1433 3113 1433 3113 4199 7146
1400 1020 1400 1020 1401 15201400 1032 1400 1032 1401 1532
200 mm320 mm
SIRCOVER by-passSIRCOVER by-pass
1401 1520 1401 1520 2799 30151401 1532 1401 1532 -
450 mm SIRCOVER by-pass - - 2799 3019
4109 0050 4109 0063 4109 0080
4109 0021 4109 0021 4109 0021
2694 3051 2694 3051 -2694 4051 2694 4051 -
1509 3063 1509 3063 1509 30801509 4063 1509 4063 1509 4080
4109 1006 4109 1006 4109 1004(5)
4109 1002 4109 1004(5)
1499 7701 1499 7701 1499 77011499 7702 1499 7702 1499 7702
1250 A 1600 A
References References
4100 3120 4100 31604100 4120 4100 41604190 3120 4190 31604190 4120 4190 4160
4100 7120 4100 71604100 9120 4100 9160
2799 7052 2799 70522799 7012 2799 7012
- -
1433 3114 1433 31141433 3113 1433 3113
4199 7146 4199 7146
1401 1520 1401 15201401 1532 1401 15322799 3015 2799 3015
- -2799 3019 2799 3019
4109 0120 4109 0160
4109 0021 4109 0021
- -- -
1509 3080 1509 31601509 4080 1509 4160
4109 1004(5) 4109 1004(5)
4109 1004(5) 4109 1004(5)
consult us consult us consult us consult us consult us
1499 7701 1499 77011499 7702 1499 7702
Locking in the 0 position with a 230 VAC undervoltage coil system
svr_
113_
a_2_
cat
svr_
053_
a_1_
cat
1800 A 2000 ASwitchesFront operation changeover switch (switch body only) - SIRCOVERNo. of poles Changeover operation type References References
3 pole I - 0 - II 4100 3180 4200 32004 pole I - 0 - II 4100 4180 4200 42003 pole I - I+II - II 4190 3180 -4 pole I - I+II - II 4190 4180 -
AccessoriesDirect operation handle
Black SIRCOVER 2799 7052 2799 7012
External operation handle
I - 0 - II IP65 1433 3113 2799 7146I - I+II - II
SIRCOVERSIRCOVER IP65 1433 3114 -
Shaft extension for external operation (for dimensions see “Accessories” pages)
200 mm 1401 1520 -320 mm 1401 1532 2799 3018
SIRCOVERSIRCOVER
Bridging bars
1 pole 4109 0160 consult us
Auxiliary contacts (1 per position)
1st AC NO/NC 4109 0021 4409 00212nd AC NO/NC 4109 0021 4409 0022
Terminal screens (1 per position)
3 pole 1509 3160 standard4 pole 1509 4160 standard
Handle key interlocking accessories - For direct front operation
Locking using RONIS EL11AP lock in position O (1) 4109 1004(2) 4409 2007Locking using RONIS EL11AP lock in position I, O, II (1) 4109 1004(2) 4409 2003Locking in the 0 position with a 230 VAC undervoltage coil system. consult us 4409 9161
Handle key interlocking accessories - For external front operation
Locking using RONIS EL11AP lock in position O (1) 1499 7701 2799 7002(2)
Locking using CASTELL type K lock in position O (1) 1499 7702 2799 7003
2500 A 3150 A
References References
4200 3250 4200 33104200 4250 4200 4310
- -- -
2799 7012 2799 7012
2799 7146 2799 7146- -
- -2799 3018 2799 3018
consult us consult us
4409 0021 4409 00214409 0022 4409 0022
standard standardstandard standard
4409 2007 4409 20074409 2003 4409 20034409 9161 4409 9161
2799 7002(2) 2799 7002(2)
2799 7003 2799 7003
(1) Lock not included.(2) This locking facility can be configured by the user in the 3 positions.
A. 116 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
��
FunctionsReferencesAccessoriesCharacteristicsDimensions
References
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
A. 117
Changeover switches
SIRCOVER andSIRCOVER by-pass
(1) Double lever handle.
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
DIRECT OPERATION
New handle=
New shaft
EXTERNAL OPERATION
T O O R D E R
+ O T H E R A C C E S S O R I E S
Directhandle
Switchbody
Switchbody
Externalhandle+ Shaft+ +
NEW
SHAFT
NEW
HANDLE
pict
o_08
0_b_
1_gb
AccessoriesDirect operation handles
acce
s_12
9_a_
1_ca
t
acce
s_15
3_a_
1_ca
t
ReferencesSIRCOVER
Rating (A) Handle colour Handle type References
125 … 630 Black Single lever 4199 5012800 … 1800 Black Single lever 2799 70522000 … 3150 Black Double lever 2799 7012
SIRCOVER by-pass
Rating (A) Handle colour Handle type References
125 … 200 Black Single lever 4199 5012250 … 630 Black Single lever 2799 7052800 … 1600 Black Double lever 2799 7012
External operation handles
acce
s_15
0_a_
1_ca
tac
ces_
151_
a_1_
cat
ReferencesSIRCOVER
Rating (A)
Changeoveroperation
typeExternal
IP(1) Handle type References
125 … 630 I - 0 - II IP55 S2 1421 2113125 … 630 I - 0 - II IP65 S2 1423 2113125 … 630 I - I+II - II IP65 S2 1423 2114800 … 1800 I - 0 - II IP65 S3 1433 3113800 … 1800 I - I+II - II IP65 S3 1433 31142000 … 3150 I - 0 - II IP65 2799 7146(1)
UseThe door interlocked externaloperation includes one lockablehandle, one escutcheon andmust be associated with a shaftextension.
SIRCOVER by-pass
Rating (A)
Changeoveroperation
typeExternal
IP Handle type References
125 … 200 I - 0 - II IP65 S2 1423 2113250 … 630 I - 0 - II IP65 S3 1433 3113800 … 1600 I - 0 - II IP65 4199 7146
125 … 200 I - 0 - II IP55 S2 1421 2113
S type handle adapter
acce
s_18
7_a_
2_ca
t
ReferenceHandle colour ReferenceExternal IP Pack qty
Black 1493 0000IP65 10
UseEnables new S type handles to be mounted using old fixingholes for replacement or retrofitapplications.DimensionsAdds 12 mm to the depth.
Alternative S type handle cover colours
acce
s_19
8_a_
2_ca
t
ReferencesHandle colour Pack qty References
Light grey 50 1401 0001Dark grey 50 1401 0011
UseFor single lever handles type S1,S2 and S3.Others colours: please consult us.
SIRCOVER
Rating (A) Shaft length (mm) Dimension X (mm) References
125 … 400 200 210 … 310 1400 1020125 … 400 320 210 … 430 1400 1032500 … 630 200 280 … 390 1400 1020500 … 630 320 280 … 510 1400 1032800 … 1800 200 425 … 577 1401 1520800 … 1800 320 425 … 697 1401 15322000 … 3150 320 653 … 923 2799 3018
SIRCOVER by-pass
Rating (A) Dimension X (mm) References
125 … 200 200 320 … 450 1400 1020125 … 200 320 320 … 570 1400 1032250 … 400 200 298 … 420 1401 1520250 … 400 320 298 … 540 1401 1532500 … 630 200 417 … 539 1401 1520500 … 630 320 417 … 659 1401 1532800 … 1600 200 550 … 680 2799 3015800 … 1600 450 550 … 800 2799 3019
UseFor standard lenghts externaloperation: - 200 mm- 320 mm- 450 mmOther lengths: please consult us.
Bridging bars
acce
s_20
5_a_
1_ca
tac
ces_
041_
a_1_
cat
ReferencesRating (A) No. of poles Section (mm) Assembly References
125 … 200 1 20 x 2.5 customer 4109 0019250 1 25 x 2.5 customer 4109 0025400 1 32 x 5 customer 4109 0039500 1 32 x 5 customer 4109 0050630 1 50 x 5 customer 4109 0063800 1 50 x 6 customer 4109 00801250 1 60 x 8 customer 4109 01201600 ... 1800 1 90 x 10 customer 4109 01602000 ... 3150 1 factory consult us
UseCreation of a common link, on the top or bottom side of the switch, in order to feedload with either power supply I or/and II.For a by-pass SIRCOVER, twosets of bridging bars are neededas the switch is composed ofthree basic switch framesPosition I: 6 or 8 polesPosition II: 3 or 4 poles
A. 118 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
�
FunctionsReferencesAccessoriesCharacteristicsDimensions
AccessoriesShaft extension for external front operation
acce
s_14
3_a_
1_ca
t
Xacce
s_03
4_a_
1_x_
cat
References
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
Shaft length (mm)
acce
s_20
8_a_
1_ca
t
SIRCOVER by-pass
SIRCOVER
SIRCOVER
svr_
068_
a_1_
x_ca
t
svr_
124_
a
SIRCOVER by-passSIRCOVER
References
2694 3014(1)(2)
2694 4014(1)(2)
2694 3021(1)(2)
2694 4021(1)(2)
2694 3051(1)(2)
2694 4051(1)(2)
A. 119
Changeover switches
SIRCOVER and SIRCOVER by-pass
Accessories
Auxiliary contacts
acce
s_06
5_a_
1_ca
tsv
r_05
8_a_
1_ca
t
ReferencesNO/NC auxiliary contact
Rating (A) Contact(s) References
125 … 1800 1st / 2nd 4109 00212000 … 3150 1st 4409 00212000 … 3150 2nd 4409 0022
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
Characteristics
Rating (A) Nominal
current (A)
Operating current Ie (A)
250 VAC 400 VAC 24 VDC 48 VDCAC-13 AC-13 DC-13 DC-13
125 … 3150 16 12 8 14 6
UsePre breaking and positions I and II signalling: 1 or 2 NO/NCauxiliary contacts in eachposition.Low level auxiliary contacts and more auxiliary contactsrequirement: please, consult us.
Connection to control circuitVia 6,35 mm fast-on tags.
Electrical characteristics30 000 operations.
Terminal shrouds
acce
s_20
6_a_
1_ca
t
References
Rating (A) No. of poles Position
125 … 200 3 top / bottom / front (I) / rear (II)125 … 200 4 top / bottom / front (I) / rear (II)250 … 400 3 top / bottom / front (I) / rear (II)250 … 400 4 top / bottom / front (I) / rear (II)500 … 630 3 top / bottom / front (I) / rear (II)500 … 630 4 top / bottom / front (I) / rear (II)
(1) To shroud front switch top and bottom 2 references requiredfor SIRCOVER and 3 references required for SIRCOVER by-pass.
(2) To fully shroud front and rear / top and bottom 4 references requiredfor SIRCOVER and 6 references required for SIRCOVER by-pass.
UseProtection against directcontacts with terminals or connecting parts.Supplied as pair.
Advantage of terminalshroudsHoles enable remote thermalchecking without removing.
Terminal screens
acce
s_20
7_a_
1_ca
t
ReferencesRating (A) No. of poles Position Pack qty References
125 … 200 3 top / bottom 2 1509 3012125 … 200 4 top / bottom 2 1509 4012250 … 400 3 top / bottom 2 1509 3025250 … 400 4 top / bottom 2 1509 4025500 … 630 3 top / bottom 2 1509 3063500 … 630 4 top / bottom 2 1509 4063800 … 1250 3 top / bottom 2 1509 3080800 … 1250 4 top / bottom 2 1509 40801600 ... 1800 3 top / bottom 2 1509 31601600 ... 1800 4 top / bottom 2 1509 41602000 … 3150 3/4 top / bottom 2 standard
UseTop or bottom protectionagainst direct contacts withterminals or connecting parts.Top and bottom pair.
Other specific accessories
bd_0
1_01
_03
• Special protection screens (for specific dimensions orhigh ambiant temperatures).
• Phase barrier shields betweenterminals.
• Connection accessories.• Low level auxiliary contacts.
Accessories
A. 120 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
��
FunctionsReferencesAccessoriesCharacteristicsDimensions
Handle key interlocking accessories
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
(1) Specific handle included.(2) This locking facility can be configured by the user in the 3 positions.
3
3125 … 630 direct
800 … 1800 direct2000 … 3150 direct
external
125 … 200
800 … 1600direct250 … 630
800 … 1600external125 … 630
2000 … 3150125 … 1800
800 … 1600125 … 630
acce
s_06
1_a_
1_x_
cat
Fig. 1
acce
s_00
1_a_
1_x_
cat
Fig. 2
acce
s_13
2_a_
1_x_
cat
Fig. 3
acce
s_15
8_a_
1_x_
cat
Fig. 4
RéférencesLockable in position I, 0 or II
Rating (A) SIRCOVER Operation Figure Reference
125 … 630 external 1 4199 5015
Locking using RONIS EL11AP lock in position 0 (not included)
Rating (A) SIRCOVER Operation Figure References
125 … 630 direct 2 4109 1006(1)
800 … 1800 direct 3 4109 1004(2)
2000 …3150 direct 3 4409 2007
external 4 1499 7701
external 2799 7002(2)
Locking using RONIS EL11AP lock in positions I, 0, II (not included)
Rating (A) SIRCOVER Operation Figure References
2 4109 1002(1)
3 4109 1004(2)
3 4409 2003
2799 7002(2)
UseCan be locked inposition 0 or in positions I, 0 or IIof front operation: • using padlock (not
supplied) (Fig.1). Thisdevice is factorymounted in the director external operationhandle. The lock escutcheoncontains sections tobe pushed outaccording to lockingposition required.However, locking inthe 3 positions forexternal operation onthe range requiresspecial orhandle.
• using a lock (notincluded) for directoperation using: - a special handle
which receives thelock bolt onSIRCOVER 125 to 630 A (Fig. 2)
- a locking disk forSIRCOVER 800 to 3150 A (Fig. 3)
• using a lock (notincluded) fordetachable externaloperation using: - a device which lifts
the lock inside thecabinet door forSIRCOVER 125 to 630 A (Fig. 4)
- a locking disk forSIRCOVER 800 to3150 A
• using undervoltagecoil for SIRCOVER800 to 3150 A.Operation onSIRCOVER is onlypossible when coil isunder voltage.
Locking using 230 VAC undervoltage coil in position 0 (factory fitted)
Rating (A) SIRCOVER Operation Figure References
direct 3 consult us
2000 … 3150 direct 3 4409 9161
Locking using CASTELL type K lock (not included)
Rating (A) SIRCOVER Operation Figure References
125 … 1800 external 4 1499 7702
2000 … 3150 external 4 2799 7003
800 … 1800
Rating (A)SIRCOVER by-pass
125 … 200
Rating (A) SIRCOVER by-pass
125 … 200
800 … 1600direct consult us250 … 630
Rating (A) SIRCOVER by-pass
consult us
Rating (A) SIRCOVER by-pass
Rating (A)SIRCOVER by-pass
125 … 630800 … 1600
4 1499 7701
800 … 1600
A. 121
Changeover switches
SIRCOVER and SIRCOVER by-pass
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
Characteristics (according to IEC 60947-3)
Rated operation currents Ie (A) Rated voltage Load duty category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)
400 VAC AC-21 A / AC-21 B 125/125 160/160 200/200 250/250 400/400 500/500 630/630AC-22 A / AC-22 B 125/125 160/160 200/200 250/250 400/400 500/500 630/630AC-23 A / AC-23 B 125/125 160/160 160/160 250/250 250/250 500/500 500/500
690 VAC(2) AC-20 A / AC-20 B 125/125 160/160 200/200 250/250 400/400 500/500 630/630AC-21 A / AC-21 B 125/125 160/160 160/160 200/250 200/250 400/400 500/500AC-22 A / AC-22 B 125/125 125/125 125/125 125/160 125/160 250/315 315/315AC-23 A / AC-23 B 63/80 63/80 63/80 100/125 100/125 160/200 160/200
220 VDC DC-20 A / DC-20 B 125/125 160/160 200/200 250/250 400/400 500/500 630/630DC-21 A / DC-21 B 125/125 160/160 160/160 250/250 250/250 500/500 630/630DC-22 A / DC-22 B 125/125 160/160 160/160 250/250 250/250 400/500 500/500DC-23 A / DC-23 B 125/125 125/125 125/125 200/200 200/200 400/400 500/500
440 VDC DC-20 A / DC-20 B 125/125 160/160 200/200 250/250 400/400 500/500 630/630DC-21 A / DC-21 B 125(3)/125(3) 125(3)/125(3) 125(3)/125(3) 200(3)/200(3) 200(3)/200(3) 400(3)/400(3) 500(3)/500(3)
DC-22 A / DC-22 B 125(3)/125(3) 125(3)/125(3) 125(3)/125(3) 200(3)/200(3) 200(3)/200(3) 315(3)/400(3) 500(3)/500(3)
DC-23 A / DC-23 B 125(4)/125(4) 125(4)/125(4) 125(4)/125(4) 200(4)/200(4) 200(4)/200(4) 400(4)/400(4) 500(4)/500(4)
(1) A/B: Category with index A = frequent operation - Category with index B = infrequent operation.(2) With terminal shrouds or phase barrier.(3) 3-pole device with 2 pole in series for the + and 1 pole for the -.(4) 4-pole device with 2 pole in series by polarity.(5) The power value is given for information only, the current values vary from one manufacturer to another.(6) For a rated operating voltage Ue = 400 VAC.(7) Increased endurances: please consult us.
Thermal current Ith (40°C) Rated insulation voltage Ui (V) 800 800 800 800 800 1000 1000Rated impulse withstand voltage Uimp (kV) 8 8 8 8 8 12 12
Operational power in AC-23 (kW)(1)(5)
At 400 VAC without pre-break AC 63/63 80/80 80/80 132/132 132/132 280/280 280/280At 690 VAC without pre-break AC 55/75 55/75 55/75 90/110 90/110 150/185 150/185
Reactive power (kvar)(5)
At 400 VAC 55 75 90 115 185 230 290
Fuse protected short-circuit withstand (kA rms prospective)(6)
Prospective short-circuit current (kA rms) 100 100 50 50 18 100 70Associated fuse rating (A) 125 160 200 250 400 500 630
Overload capacityRated short-time withstand current 1 s. Icw (kA rms) 7 7 7 9 9 13 13Short-circuit making capacity (kA peak)(6) 20 20 20 30 30 45 45
630 A500 A125 A 160 A 200 A 250 A 400 A
ConnectionMinimum Cu cable section (mm2) 35 50 50 95 185 240 2 x 150Minimum Cu busbar section (mm2) - - - - - - 2 x 30 x 5Maximum Cu cable section (mm2) 50 95 95 150 240 240 2 x 300Maximum Cu busbar width (mm) 25 25 25 32 32 40 50Min. tightening torque (Nm) 9 9 9 20 20 20 20
Mechanical characteristicsEndurance (number of operating cycles)(7) 10 000 10 000 10 000 10 000 10 000 5 000 5 000Weight of 3 p switch (kg) 1.5 1.6 1.8 2 3 3.5 3.5Weight of 4 p switch (kg) 1.6 1.7 1.9 2.1 3.5 4 4
A. 122 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
��
FunctionsReferencesAccessoriesCharacteristicsDimensions
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
Characteristics (according to IEC 60947-3)
Rated operation currents Ie (A) Rated voltage Load duty category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)
400 VAC AC-21 A / AC-21 B 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3150/3150AC-22 A / AC-22 B 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2000/2500 2500/2500AC-23 A / AC-23 B 800/800 1250/1250 1250/1250 1250/1250 1250/1250 1250/1250 1250/1250
690 VAC(2) AC-20 A / AC-20 B 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3150/3150AC-21 A / AC-21 B 800/800 800/800 1000/1000 1000/1000 2000/2000 2000/2500 2000/2500AC-22 A / AC-22 B 800/800 800/800 1000/1000 1000/1000 1000/1000 1000/1000 1000/1000AC-23 A / AC-23 B 200/250 200/250 500/500 500/500 800/800 800/800 800/800
220 VDC DC-20 A / DC-20 B 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3150/3150DC-21 A / DC-21 B 800/800 1250/1250 1250/1250 1250/1250 2000/2000 2000/2500 2000/2500DC-22 A / DC-22 B 800/800 1250/1250 1250/1250 1250/1250 1250/1600 1250/1600 1250/1600DC-23 A / DC-23 B 800/800 1250/1250 1250/1250 1250/1250 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3)
440 VDC DC-20 A / DC-20 B 800/800 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3150/3150DC-21 A / DC-21 B 800(3)/800(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250/1250 1250/1250 1250/1250DC-22 A / DC-22 B 800(3)/800(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3)
DC-23 A / DC-23 B 800(3)/800(3) 1250(3)/1250(3) 1250(3)/1250(3) 1250(3)/1250(3) 1000(3)/1000(3) 1000(3)/1000(3) 1000(3)/1000(3)
(1) A/B: Category with index A = frequent operation - Category with index B = infrequent operation.(2) With terminal shrouds or phase barrier.(3) 4-pole device with 2 pole in series by polarity.(4) The power value is given for information only, the current values vary from one manufacturer to another.(5) For a rated operating voltage Ue = 400 VAC.(6) Increased endurances: please consult us.
Thermal current Ith (40°C) Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000Rated impulse withstand voltage Uimp (kV) 12 12 12 12 12 12 12
Operational power in AC-23 (kW)(1)(4)
At 400 VAC without pre-break AC 450/450 710/710 710/710 710/710 710/710 710/710 710/710At 690 VAC without pre-break AC 185/220 185/220 475/475 475/475 750/750 750/750 750/750
3150 A2500 A800 A 1250 A 1600 A 1800 A 2000 A
Reactive power (kvar)(4)
At 400 VAC 365 575 - - - - -
Fuse protected short-circuit withstand (kA rms prospective)(5)
Prospective short-circuit current (kA rms) 50 100 100 100 100 100 -Associated fuse rating (A) 800 1250 2 x 800 2 x 800 2 x 1000 2 x 1250 -
Overload capacityRated short-time withstand current 1 s. Icw (kA rms) 26 35 50 50 50 50 55Short-circuit making capacity (kA peak) (5) 55 80 110 110 110 110 120
ConnectionMinimum Cu cable section (mm2) 2 x 185 - - - - - -Minimum Cu busbar section (mm2) 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5 2 x 80 x 5 3 x 100 x 5 4 x 100 x 5 4 x 100 x 5Maximum Cu cable section (mm2) 2 x 300 4 x 185 6 x 185 6 x 185 - - -Maximum Cu busbar width (mm) 63 63 100 100 125 125 125Min. tightening torque (Nm) - 20 40 40 40 40 40
Mechanical characteristicsEndurance (number of operating cycles)(6) 3 000 3 000 4 000 4000 3 000 2 500 2 500Weight of 3 p switch (kg) 17.5 22.5 34 34 70 72 98Weight of 4 p switch (kg) 21 27.5 42 42 85 88 110
A. 123
Changeover switches
SIRCOVER and SIRCOVER by-pass
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
Dimensions• SIRCOVER 125 to 1800 ADirect front operation External front operation
BA
CA
CA
AA
AC
M10A
XJ
T T T
N
U W
O
III
ZY
C 18H
L1
V
Y
Z1
II I
H
E min.
HA
8.5 1
40
4 Ø 7Ø 37
28
A
B
45
125
61
210
0
II
I
90°
90°2
svr_
072_
f_1_
x_ca
t
• SIRCOVER 2000 to 3150 A
Direct front operation External front operation
610518
4’-8’2’-6’ 4-8 2-6
1’-5’
Z3Z2
Z1Z Y Y
3’-7’ 1-5 3-7
60.5 12012.5 120 120 46.5 51.5
561
350
AA
11
7 - 7’ 5 - 5’ 3 - 3’ 1 - 1’
8 - 8’ 6 - 6’ 4 - 4’ 2 - 2’
M 88F
A
1
590 110
545
50
50
4 ø 4.5ø 31
65
2
545
svr_
095_
b_1_
x_ca
t
1. Terminal screen. 2. Minimum length with shaft extension: 650.
Rating(A)
Overall dimensions Switch body Switch mounting Connection terminalsA 3p. A 4p. F 3p. F 4p. M 3p. M 4p. Y Z Z1 Z2 Z3 AA
2000 576 696 447.5 567.5 347 467 10 78.5 225.5 309.5 456.5 4552500 576 696 447.5 567.5 347 467 10 78.5 225.5 309.5 456.5 4553150 576 696 447.5 567.5 347 467 15 78.5 230.5 309.5 461.5 505
A. External operation handle S2 type: 125 to 630 A.
B. External operation handle S3 type: 800 to 1800 A.
1. Terminal shrouds.
2. Direct operation handle:
- 125 to 630 A: L1 = 140 mm.- 800 to 1800 A: L1 = 210 mm.
Rating(A)
Overall dimensions Switch body Switch mounting Connection terminalsA 3p. A 4p. C E min AC H HA J 3p. J 4p. M 3p. M 4p. N T U V W X 3p. X 4p. Y Z Z1 AA BA CA
125 221 251 218 210 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 135 115 10160 221 251 218 210 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 135 115 10200 221 251 218 210 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 135 115 10250 262 312 218 210 280 148 25 223 273 196 246 116 50 25 30 11 61 61 3.5 30 124 160 130 10400 262 312 218 210 280 148 25 223 273 196 246 116 50 35 35 11 61 61 3.5 30 124 170 140 15500 319 379 295 280 401 225 25 272 332 246 306 176 65 32 37 13 70.5 65.5 5 43 180 235 205 15630 319 379 295 280 400 225 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 260 220 20800 386 466 375 425 459 298 29 306.5 336 336 250 80 50 60,5 15 48 48 7 66.5 253.5 321 26.51250 386 466 375 425 459 298 29 306.5 336 336 250 80 60 65 48 48 7 66.5 255.5 330 29.51600 478 598 375 425 461 298 29 388.5 347 467 250 120 90 43.5 54 54 8 66.5 255.5 288 151800 478 598 375 425 461 298 29 388.5 347 467 250 120 90 43.5 54 54 8 66.5 255.5 288 15
386.5386.5518.5518.5
16x1112.5x512.5x5
Terminalshrouds
BA
CA
CA
AA
AC
M10A
X T TJ
T
N
U W8.5
O
III
H
Y Y YZ
Z1Z2
C 18
V
L1
I III
1
40
4 Ø 7Ø 37
28
HE min.
HA 45
125
61
210
B
A
504 Ø 4.5
Ø 31
50
0
II
I
90°
90°
HE min.
HA
103
330
==
C
0
II
I
90°
90°
2
svr_
070_
g_1_
x_ca
t
A. 124 This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
�
FunctionsReferencesAccessoriesCharacteristicsDimensions
Changeover switches
SIRCOVER andSIRCOVER by-pass125 to 3150 A
SOCOMEC general catalogue
Dimensions• SIRCOVER by-pass 125 to 1600 A
Direct front operation
A. External operation handle S2 type: 125 to 200 A.
B. External operation handle S3 type: 250 to 630 A.
C. External operation handle: 800 to 1600 A.
1. Terminal shrouds.2. Direct operation handle:
- 125 to 200 A: L1 = 140 mm.- 250 to 630 A: L1 = 210 mm.- 800 to 1600 A: L1 = Ø 330 mm.
Rating(A)
Overalldimensions
Terminalshrouds
Switchbody
Switchmounting Connection terminals
A 3+6 p
A 4+8 p
C Emin.
AC H HA J 3+6 p
J 4+8 p
M 3+6 p
M 4+8 p
N T U V W X 3+6 p
X 4+8 p
Y Z Z1 Z2 AA BA CA
125 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 219 135 115 10160 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 219 135 115 10200 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 219 135 115 10250 262 312 313 298 280 243 25 223 273 196 246 116 50 25 30 11 61 61 3.5 30 124 219 160 130 10400 262 312 313 298 280 243 25 223 273 196 246 116 50 35 35 11 61 61 3.5 30 124 219 170 140 15500 319 379 432 417 401 362 25 272 332 246 306 176 65 32 37 13 70.5 65.5 5 43 180 317 235 205 15630 319 379 432 417 400 362 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 317 260 220 20800 386 466 560 550 459 479 29 306.5 386.5 255 335 250 80 50 60.5 15 48 48 7 66.5 253.5 439.5 321 26.51250 386 466 560 550 459 479 29 306.5 386.5 255 335 250 80 60 65 48 48 7 66.5 253.5 439.5 320 29.251600 478 598 560 550 461 479 29 388.5 518.5 347 467 250 120 90 54 54 8 66.5 253.5 439.5 288 15
16 x 1143.5
External front operation
12.5 x 5
A. 125
Changeover switches
SIRCOVER and SIRCOVER by-pass
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify featureswithout prior notice in view of continued improvement. 2006-2007
Dimensions
• SIRCOVER 2000 to 2500 A
ø 13
4020
4020 20
80
svr_
079_
a_1_
x_ca
t
9650
50 25
28
4 x Ø 6.5 3 x Ø 6.5Ø 31
sirc
o_22
4_b_
1_x_
cat
• SIRCOVER 3150 A50
25
5035 35120
ø 13
100
svr_
080_
b_1_
x_ca
t
Connection terminals
�
Door drilling with CASTELL K lock
�
Door drilling with RONIS EL11AP lock
�
20 20
Ø 37
Ø 37
2 Ø 6.5
4 Ø 7
1414
7922
45°
28.5
svr_
101_
a_1_
x_ca
t
• SIRCOVER 125 to 1800 A SIRCOVER by-pass 125 to 630 A
33 8.58.5
50
3310
ø 9
ø 15
svr_
077_
a_1_
x_ca
t
16 x 11
60
28.5 15.7515.75
28.5
15
svr_
078_
b_1_
x_ca
t55
12.5
3025
90
ø12.5
453025
45
15
sirc
o_27
1_a_
1_x_
cat
20
4 Ø 5.5Ø 26
20
Ø 37
4 Ø 7
1414
73.5
2624
45° 3.5
28
svr_
102_
a_1_
x_ca
t
• SIRCOVER 2000 to 3150 A andSIRCOVER by-pass 800 to 1600 A
• SIRCOVER and SIRCOVER by-pass 800 A
• SIRCOVER and SIRCOVER by-pass 1250 A
• SIRCOVER 1600 to 1800 ASIRCOVER by-pass 1600 A
• SIRCOVER 125 to 1800 ASIRCOVER by-pass 125 to 630 A
top related