35 oxygen
Post on 21-Sep-2014
138 Views
Preview:
DESCRIPTION
TRANSCRIPT
SINGLE AISLE TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 (V2500-A5/ME) OXYGEN
This document must be used for training purposes only
Under no circumstances should this document be used as a reference
It will not be updated.
All rights reservedNo part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,without the prior written permission of AIRBUS S.A.S.
OXYGEN
GENERAL
Oxygen Level 2 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CREW OXYGEN
Crew OXY Mask Utiliz/Stowage/Tests (2) . . . . . . . . . . . . . . . . . . . . 20
PASSENGER OXYGEN
Passenger Oxygen System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . 22Passenger Oxygen Unit D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
PORTABLE OXYGEN
Crew Portable Oxygen System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . 34Cabin Portable Oxygen Equipment D/O (3) . . . . . . . . . . . . . . . . . . . 40
MAINTENANCE PRACTICE
Crew Oxygen Cylinder Removal & Installation (3) . . . . . . . . . . . . . . 46
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
TABLE OF CONTENTS May 11, 2006Page 1
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
OXYGEN LEVEL 2 (2)
SYSTEM OVERVIEW
The oxygen system consists of:- crew system,- passenger system,- portable system.The flight crew oxygen system supplies oxygen to the flight crew. It isused if there is a loss of cabin pressurization or smoke or dangerous gasesin the cockpit.The oxygen is supplied by a high pressure oxygen cylinder to quickdonning masks in the cockpit.Passenger Oxygen SystemThe passenger and cabin attendant oxygen system is supplied by chemicaloxygen generator units located in the cabin, cabin attendant stations,lavatories and galleys.Two types of chemical generators are offered which provide oxygen for15 minutes or 22 minutes.Portable Oxygen SystemThe portable oxygen system supplies oxygen to the passengers, the cabinattendants and the flight crew in an emergency and for first aid treatment.The smoke hood system provides breathing means and eye protectionfor the flight crew members and cabin attendants.It permits them to move freely to extinguish a fire.The high pressure portable cylinder with continuous flow type maskssupplies first aid oxygen for the passengers.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 2
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
SYSTEM OVERVIEW
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 3
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
SYSTEM OVERVIEW (continued)
FLIGHT CREW OXYGEN SYSTEMThe flight crew oxygen is supplied from a high-pressure oxygencylinder at a pressure of 127.5 bar (1.850 psig).This cylinder can be isolated for maintenance by a manual ON/OFFvalve.A direct-reading pressure gage gives an indication of the cylinderpressure, independent of the open or closed position of the manualvalve.The cylinder is installed in a cradle with two quick-release clamps inthe L/H avionics compartment.A pressure regulator transmitter assembly is directly connected to thecylinder.It consists of a high-pressure stage with an integrated pressuretransducer for ECAM indication and a low pressure stage.The pressure regulator regulates the low pressure at 4.48 to 6.48 bar(65 to 94 psig).A supply valve opens or closes the crew oxygen supply. The CREWSUPPLY P/B on the oxygen panel controls the supply valve.High pressure and low pressure protection is achieved by safetydevices consisting of a high-pressure safety outlet and a low pressuresafety outlet.The high-pressure safety outlet is a frangible disk type. The lowpressure safety outlet is a pressure relief valve.An overboard green discharge indicator is connected to the highpressure safety outlet and to the low pressure safety outlet.In case of over pressure, the green disk blows out and a yellowindicator is displayed showing that the cylinder has discharged or thepressure relief valve has opened.A pressure switch and a test port are connected to the distributionmanifold.
The pressure switch operates when the oxygen supply pressuredecreases to 3.45 plus or minus 0.35 bar (50 plus or minus 5 psig) andtransmits a warning signal REGUL LO PR to the ECAM/DOOR/OXYpage.On the lower ECAM DU, on the DOOR/OXY page, the oxygenpressure in the cylinder is indicated as follows:(a) 0 to 27.5 bar (0 to 400 psig) in amber.(b) 27.5 to 127.5 (400 to 1850 psig) in green.(c) An amber half frame appears when the oxygen pressure is lowerthan 1500 psig.If the oxygen pressure drops below the minimum operating pressureof 3.45 plus or minus 0.35 bar (50 plus or minus 5 psig), the indicationREGUL LO PR is shown amber on the DOOR/OXY page.The mask assembly and the stowage box are installed adjacent to eachcrew member seat.The stowage box contains the mask, when the mask is pulled out ofthe box a supply valve installed in the stowage box will open and letoxygen flow to the mask.To use the mask, squeeze the red clips. This will inflate the maskharness.Bring the mask in position and release the red clips.Releasing the red clips will stop oxygen flow to the harness and ventthe oxygen remaining in the harness to the atmosphere.Now the mask is ready for use.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 4
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
SYSTEM OVERVIEW - FLIGHT CREW OXYGEN SYSTEM
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 5
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
SYSTEM OVERVIEW (continued)
PASSENGER OXYGEN SYSTEMThe masks are dropped automatically when the cabin altitude is higherthan 14000 feet or manually by crew action on the MASK MANualON pushbutton.A taped message is transmitted on the passenger address system.The passenger SYStem ON indicator light comes on white when thepassenger oxygen system is electrically supplied.A reset is available to rearm the electrical system after mask restowage.A release tool allows manual opening of the door in case of failure ofthe container door opening system.When the TiMeR RESET pushbutton is pressed, the ON white lightof the TMR RESET pushbutton comes on.The indicator light SYS ON goes off and the taped announcementstops.On ground, used chemical oxygen units must be replaced and allmasks re stowed.The system is reset by momentarily pressing the TMR RESETpushbutton on the maintenance panel.Manually operated doors stops are fitted on the container doors toallow an operational test of the mask release system.When set to test position the door stops will prevent doors from fullyopening and masks from dropping out of the container.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 6
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
SYSTEM OVERVIEW - PASSENGER OXYGEN SYSTEM
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 7
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
SYSTEM OVERVIEW (continued)
CREW PORTABLE OXYGEN SYSTEMThe crew oxygen bottle pressure is indicated on the bottle directreading gage.Correct pressure is shown when the needle is in the FULL range ofthe gage.Incorrect pressure will lead to portable oxygen bottle replacement.The smoke hood is vacuum packed in a transport/storage container.The container is provided with two indications, which are used forpreflight inspection:- A good condition indicator: green - operational, red - not operational),- A tamper seal (in position - operational, broken - not operational).
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 8
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
SYSTEM OVERVIEW - CREW PORTABLE OXYGEN SYSTEM
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 9
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
SERVICING
CREW OXYGEN CYLINDERREMOVAL/INSTALLATIONThe oxygen cylinder has to be removed in case of low contents (lowpressure) or leakage and replaced by a fully charged cylinder.Put the access platform in position and open the access door 812.Close the oxygen cylinder ON/OFF valve.Bleed and empty the oxygen system:- press the OXYGEN/CREW SUPPLY pushbutton,- on one of the oxygen masks, actuate the PRESS TO TEST ANDRESET slider several times to empty the system,- release the OXYGEN/ CREW SUPPLY P/B.Open, safety and tag the OXYGEN/ CREW/OXYgen/ SupPLY circuitbreaker 1HT.Disconnect the pressure regulator transmitter assembly from theoxygen cylinder.Put a blanking cap on the pressure regulator and put it in a sealedvinyl bag.Put an oxygen cylinder cap on the cylinder valve.Disconnect the HP safety hose from the cylinder head; discard thesleeve and put a blanking cap on the union.Put an oxygen cylinder stowage cap on the cylinder valve.Loosen the nut and disengage the pin from the clamp to remove thecylinder from the support.Make sure that the parts retained from the removed component areclean and in the correct condition.Check the expiration date on the cylinder to make sure it can still beused.Carefully put the cylinder on the support.Close the clamp and tighten the pin.Remove the oxygen cylinder stowage cap from the cylinder valve.
Remove the blanking cap from the HP safety connector.Put a new sleeve on the union and tighten the HP safety connector onthe cylinder head.Remove the blanking cap from the pressure regulator transmitterassembly and the corresponding stowage cap on the cylinder head.Put the regulator on the valve and tighten the nut.Apply the SPECIAL MATERIAL solution to the mechanicalconnections.Very slowly, open the valve of the cylinder 3.5 to 4 turns.Let the pressure become stable, this occurs after approximately 90seconds. Fully open the cylinder valve.Examine each connection to make sure that there are no leaks.Rub off the SPECIAL MATERIAL solution.Make sure that the work area is clean and clear of tools and otheritems.Close the access door 812.Remove the safety clip and the tag. Close the circuit- breaker 1HT.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 10
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
SERVICING - CREW OXYGEN CYLINDER REMOVAL/INSTALLATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 11
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
SERVICING (continued)
SAFETY PRECAUTIONSKeep all hydrocarbons (fuels, lubricants, etc. ) away from oxygensources.Oxygen becomes explosive when it comes in contact withhydrocarbons.Clean the tools and make sure your hands are clean to preventcontamination of the oxygen system.Put dry and clean, metal or plastic plugs on all pipes or units removedtemporarily.Put each pipe or unit in a sealed vinyl bag.
CAUTION: DO NOT PULL THE GENERATOR-END OF THELANYARD.YOU MUST INSTALL THE SAFETY RINGS OR THESAFETY PINS IF YOU:- MOVE THE GENERATORS TO A DIFFERENTLOCATION, OR- PUT THEM INTO STORAGE.IF YOU DO NOT, THE GENERATORS CANOPERATE AND CAUSE DAMAGE.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 12
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
SERVICING - SAFETY PRECAUTIONS
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 13
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
DAILY CHECK
During the daily check the external walk around will include the visualcheck of the crew oxygen cylinder overpressure (Green) discharge discto be sure that it is not missing.The ECAM DOOR/OXY page shows the crew oxygen pressure indication.If the pressure is less than 1500 PSI a half box (advisory) is shown forinformation.In this case, check the AMM. This is to see if the minimum oxygenpressure available to the flight crew is within the permitted limits.Refer to the minimum flight crew oxygen pressure chart and find theMinimum Pressure according to the ambient temperature and the numberof crew members.If the pressure is less than the minimum flight crew oxygen pressure theoxygen cylinder must be changed.Push the reset test slider, the blinker turns yellow and goes back to blackagain showing that the regulator is leak tight.Press the harness inflation control, the blinker turns yellow and goes backto black again showing that the harness is leak tight.Pressing the emergency rotation knob tests the on demand system.The microphone is tested by activating the loudspeakers, the interphone,and by pressing the emergency rotation knob.When the tests are completed, make sure that the NORMAL / 100%selector is locked in the 100% position, and the reset slider returns to theUP position.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 14
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
DAILY CHECK
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 15
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
DAILY CHECK
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 16
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
This Page Intentionally Left Blank
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 17
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
OXYGEN LEVEL 2 (2)
MAINTENANCE TIPS
CREW OXYGEN MASK STOWINGProper stowing of the mask is essential for quick and efficient donningof the mask.Open the stowage box flap doors and position the flexible hosecorrectly.Engage the mask assembly with the regulator on top.Close the left flap door carefully while pushing the reset test slider toretract the OXY ON flag.At the end of the re stowing operation, do the IN SITU TEST.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 18
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
MAINTENANCE TIPS - CREW OXYGEN MASK STOWING
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
OXYGEN LEVEL 2 (2) May 10, 2006Page 19
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
BA
0000
0000
1
CREW OXY MASK UTILIZ/STOWAGE/TESTS (2)
UTILIZATION
The mask assembly and the stowage box are installed adjacent to eachcrewmember seat. The stowage box contains the mask, when the maskis pulled out of the box, a supply valve installed in the stowage box willopen and let oxygen flow to the mask. To use the mask, squeeze the redclips, which will inflate the mask harness; releasing the red clips willstop oxygen flow to the harness and vent the oxygen remaining in theharness to the atmosphere. Oxygen flow is indicated by the blinkershowing yellow and an OXY ON flag, which appears on the left doorwhen closed. The mask regulator provides either normal or pure oxygenby means of a Normal/100% selector. In the Normal position, the userbreathes a mixture of cabin air and oxygen. When the selector is in the100% position, the user will breathe pure oxygen. When the emergencyrotation knob is rotated and the Normal/100% selector in the 100%position, the mask regulator supplies pure oxygen at a permanent positivepressure. To take the mask off, the harness has to be inflated. This is doneby operating the red clips.
STOWAGE
Proper stowing of the mask is essential for quick and efficient donningof the mask. Open the stowage box flap doors, and position the flexiblehose correctly. Engage the mask assembly, regulator on top. Close theleft flap door carefully while pushing the reset test slider to retract theOXY ON flag. At the end of the restowing operation, do the: IN SITUTESTING.Associated film is UM35D1T20S00001.MPG. The above text is fordocumentation only. Do not record this text; do not put it in ATLASmodule.
TESTS
Push the reset test slider. The blinker turns yellow and goes black againshowing that the regulator is leak tight.Press the harness inflation control. The blinker turns yellow and goesblack again showing that the harness is leak tight. The on demand systemis tested by pressing the emergency rotation knob.The microphone is tested by activating the loudspeakers, the interphone,and by pressing the emergency rotation knob. When the previous testsare completed, make sure that the Normal/100 % selector is locked inthe 100% position, and the reset test slider return to the UP position.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXY MASK UTILIZ/STOWAGE/TESTS (2) May 10, 2006Page 20
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D10
0000
0001
UTILIZATION ... TESTS
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXY MASK UTILIZ/STOWAGE/TESTS (2) May 10, 2006Page 21
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D10
0000
0001
PASSENGER OXYGEN SYSTEM D/O (3)
TRIGGERING
In case of rapid cabin depressurization, oxygen masks are automaticallydropped to passengers.Ttwo types of chemical generators are offered which supply oxygen for15 minutes or 22 minutes.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 22
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
TRIGGERING
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 23
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
PASSENGER OXYGEN SYSTEM D/O (3)
AUTOMATIC OPERATION
The system operates automatically when the altitude pressure switchcloses. A taped announcement is transmitted over the Passenger Addresssystem and passenger oxygen masks are released. The SYStem ON whiteindicator light comes on. 6 seconds after system activation, relay 25WRis on to interconnect the LH and RH latch assembly electrical circuits.This ensures that all oxygen unit electrical latches remain energized if acircuit is damaged in the event of engine turbine bursting. The TIMEDELAY RELAYS (8WR, 9WR and 15WR) switch off the power supplyto the POWER SUPPLY RELAY after 30 seconds. Pressing momentarilythe TiMeR RESET P/B on the maintenance panel stops the announcementand the indicator light SYS ON goes off.
NOTE: The diagram shows the system when the 30 seconds are notelapsed yet.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 24
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
AUTOMATIC OPERATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 25
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
PASSENGER OXYGEN SYSTEM D/O (3)
MANUAL OPERATION
The passenger oxygen masks may be presented at any time by pressingthe MASK MAN ON pushbutton. The SYS ON white indicator lightcomes on. 6 seconds after system activation, relay 25WR is on tointerconnect the LH and RH latch assembly electrical circuits. Thisensures that all oxygen unit electrical latches remain energized if a circuitis damaged in the event of engine turbine bursting. Pressing momentarilythe TiMeR RESET P/B on the maintenance panel stops the announcementand the indicator light SYS ON goes off.
NOTE: The diagram shows the system when the 30 seconds are notelapsed yet.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 26
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
MANUAL OPERATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 27
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
PASSENGER OXYGEN SYSTEM D/O (3)
RESET OPERATION
When the TMR RESET P/B is pressed, the ON white light comes on.The indicator light SYS ON goes off and the taped announcement stops.On ground, used chemical oxygen units must be replaced, all masksstowed and oxygen container doors must be latched closed. The systemis reset by momentarily pressing the TMR RESET P/B on the maintenancepanel.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 28
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
RESET OPERATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 29
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
PASSENGER OXYGEN SYSTEM D/O (3)
FAULT OPERATION
When the cabin altitude is more than 14.000 ft and relay 8WR and 9WRremain open after delay:- relay 15WR is energized,- the FAULT amber light comes on,- the SYS ON white light and Passenger Address systems are still on.The FAULT light on the TMR RESET P/B comes on if a failure of theTIME DELAY RELAYS occurs.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 30
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
FAULT OPERATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN SYSTEM D/O (3) May 10, 2006Page 31
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D20
0000
0001
PASSENGER OXYGEN UNIT D/O (3)
MASK OPERATION
As soon as the emergency oxygen container doors open, the masks fallout. They are hung on lanyards within the reach of users. When the firstuser pulls the mask towards his face, the release pin starts the chemicalgeneration. Oxygen flows through the flexible supply hose to the mask.The flow indicator shows a green stripe.
CHEMICAL OXYGEN GENERATION
The chemical generator uses the basic principal of thermal decompositionof sodium chlorate.A thermal indicator shows the generator condition. According to thegenerator type, there can be two different indicators:1- Black: the oxygen generator has been burned out.- Yellow: the oxygen generator is new.2- Blue: the oxygen generator has been burned out.- Pink: the oxygen generator is new.The chlorate core is fitted in a stainless steel housing.
GENERATOR OPERATION
By pulling the release pin of the starter assembly the spring loaded firingpin will hit the percussion cap. The heat produced in the percussion capwill then activate the starting powder of the generator.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN UNIT D/O (3) May 10, 2006Page 32
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D30
0000
0001
MASK OPERATION ... GENERATOR OPERATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
PASSENGER OXYGEN UNIT D/O (3) May 10, 2006Page 33
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D30
0000
0001
CREW PORTABLE OXYGEN SYSTEM D/O (3)
GENERAL
The crew smoke hood system provides eyes protection and suppliesoxygen to the crew member in case of emergency: fire, or an emissionof smoke or noxious gases. The crew smoke hood system allows freedomof movement to extinguish a fire.
LOCATION
The complete hood is vacuum-packed in a transport/storage container.A breathing hood container is installed in the cockpit. Smoke hoods forcabin crew are installed in cabin.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW PORTABLE OXYGEN SYSTEM D/O (3) May 10, 2006Page 34
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D40
0000
0001
GENERAL & LOCATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW PORTABLE OXYGEN SYSTEM D/O (3) May 10, 2006Page 35
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D40
0000
0001
CREW PORTABLE OXYGEN SYSTEM D/O (3)
DESCRIPTION
The container is installed with a tamper seal and a serviceability indicatorfor the preflight inspection; the serviceability indicator is broken afteropening the box.
NOTE: According to the supplier, another indicator is available whichshows a yellow indicator if the container has not been opened.
The protective breathing hood works with a closed breathing circuit. Thesystem is activated by a starter via a lanyard. The expired air will beregenerated, enriched with oxygen, and inhaled again. The oxygen isgenerated in exothermic chemical reaction between the potassiumperoxide (KO2), the humidity, and the carbon dioxide (CO2) in the expiredair; this reaction releases heat. The protective breathing equipment iscomposed of three main parts:A hood with:- the neck seal at the level of the neck,- the straps attached to the hood maintain the inner mask around the backof the user head,- a relief valve in the hood, which keeps the overpressure in the hood ata comfortable level.An inner mask installed with:- an anti-suffocation valve, operated by a higher breathing resistance.The user can inhale through this valve from the volume between headand hood,- a speech transmitter is located in front of the oronasal mask.A KO2 cartridge has:- an attached breathing bag installed with a volume-controlled reliefvalve,- a starter activated by a lanyard,- a fold tube (or breathing hose) connected to the oronasal mask,- a belt, which holds the cartridge on the hood.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW PORTABLE OXYGEN SYSTEM D/O (3) May 10, 2006Page 36
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D40
0000
0001
DESCRIPTION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW PORTABLE OXYGEN SYSTEM D/O (3) May 10, 2006Page 37
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D40
0000
0001
CREW PORTABLE OXYGEN SYSTEM D/O (3)
OPERATION
The breathing hood is stored under a vacuum in a specially designed bag.The bag is mounted inside a box in such a way that, after opening thebox, the hood is removed and the vacuum protection is automaticallyopened with a single movement. The hood is fire resistant.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW PORTABLE OXYGEN SYSTEM D/O (3) May 10, 2006Page 38
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D40
0000
0001
OPERATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW PORTABLE OXYGEN SYSTEM D/O (3) May 10, 2006Page 39
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D40
0000
0001
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3)
BOTTLE
The oxygen source is a high-pressure cylinder. The high-pressurecylinders are installed in brackets with quick-release clamps.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3) May 10, 2006Page 40
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D50
0000
0001
BOTTLE
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3) May 10, 2006Page 41
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D50
0000
0001
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3)
FIRST AID MASK
The continuous-flow first aid oxygen mask supplies oxygen fortherapeutic purposes. The flexible supply hose connects the mask to thecalibrated continuous-flow outlet of the bottle.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3) May 10, 2006Page 42
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D50
0000
0001
FIRST AID MASK
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3) May 10, 2006Page 43
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D50
0000
0001
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3)
SMOKE HOOD SYSTEM
The smoke hood system gives breathing means and eyes protection forone user in case of: fire, or emission of smoke and/or noxious gases. Itlets the user move freely. The smoke hood container is installed with agood-condition indicator and a tamper seal for the pre-flight inspection.The annular container in the hood, full of compressed oxygen, releasesthe amount of oxygen that the user needs. The gas circulation is generatedwhen the user breathes in and out. Cockpit smoke hood container can beoptionally installed in the cabin.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3) May 10, 2006Page 44
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D50
0000
0001
SMOKE HOOD SYSTEM
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CABIN PORTABLE OXYGEN EQUIPMENT D/O (3) May 10, 2006Page 45
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
D50
0000
0001
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3)
REMOVAL
WARNING: KEEP ALL HYDROCARBONS (FUEL, LUBRICANTS,ETC...) AWAY FROM ALL SOURCE OF OXYGEN.OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHESHYDROCARBONS.CLEAN THE TOOLS AND MAKE SURE YOUR HANDSARE CLEAN TO PREVENT CONTAMINATION OF THEOXYGEN SYSTEM.
JOB SET-UP (1/2)Put the access platform in position and open the access door 812.Energize the aircraft electrical circuits; make sure that the avionicsequipment ventilation operates correctly.Close the valve of the oxygen cylinder valve assembly.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 46
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
REMOVAL - JOB SET-UP (1/2)
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 47
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3)
REMOVAL (continued)
JOB SET-UP (2/2)Bleed and empty the oxygen system:- Press the OXYGEN/CREW SUPPLY P/BSW. The OFF legend goesoff.- On one of the oxygen masks, actuate the PRESS TO TEST ANDRESET slider several times to empty the system.- Release the OXYGEN/CREW SUPPLY P/BSW. The OFF legendcomes on.- Put a warning notice to tell persons not to push the OXYGEN/CREWSUPPLY P/BSW.Open, safety and tag the CREW OXY SPLY circuit breaker.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 48
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
REMOVAL - JOB SET-UP (2/2)
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 49
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3)
REMOVAL (continued)
PROCEDURELoosen the nut and disconnect the pressure regulator transmitter fromthe oxygen cylinder.Put a blanking cap on the pressure regulator and put it in a sealedvinyl bag.Put an oxygen cylinder stowage cap on the cylinder valve.Disconnect the union and discard the bush.Put a blanking cap on the union.Put an oxygen cylinder stowage cap on the cylinder valve.Loosen the nut and disengage the pin from the clamp to remove thecylinder from the support.
INSTALLATION
Make sure that the aircraft is in the same configuration as for the removaloperation.Make sure that the parts retained from the removed component are cleanand in the correct condition.
PROCEDURECheck the expiration date on the cylinder to make sure it can still beused.Carefully put the cylinder on the support, close the clamp and tightenthe pin.Remove the oxygen cylinder stowage cap from the cylinder valve.Remove the blanking cap from the union.Put a new bush on the union and tighten it.Remove the blanking cap from the pressure regulator transmitterassembly and the corresponding stowage cap on the cylinder head.Put the regulator on the valve and torque the nut.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 50
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
REMOVAL & INSTALLATION
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 51
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3)
INSTALLATION (continued)
Leak testApply the special materials solution to the mechanical connections.Very slowly, open the valve of the cylinder 3.5 to 4 turns.Let the pressure become stable, this occurs after approximately 90seconds.Fully open the cylinder valve.Examine each connection to make sure that there are no leaks.Rub off the special materials solution.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 52
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
INSTALLATION - LEAK TEST
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 53
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3)
INSTALLATION (continued)
Close-upRemove the safety clip and the tag and close the circuit breaker.Make sure that the work area is clean and clear of tools and otheritems.Remove the warning notice.De-energize the aircraft electrical circuits.Close the access door 812 and remove the access platform.
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 54
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
INSTALLATION - CLOSE-UP
MAINTENANCE COURSE - T1 (V2500-A5/ME) 35 - OXYGEN
CREW OXYGEN CYLINDER REMOVAL & INSTALLATION (3) May 10, 2006Page 55
SINGLE AISLE TECHNICAL TRAINING MANUALU
3U06
191
- U
15T
1M0
- U
M35
Y10
0000
0001
AIRBUS S.A.S.31707 BLAGNAC cedex, FRANCE
STMREFERENCE U3U06191
MAY 2006PRINTED IN FRANCEAIRBUS S.A.S. 2006
ALL RIGHTS RESERVED
AN EADS JOINT COMPANYWITH BAE SYSTEMS