BACKGROUND ALARM SYSTEM OF ZXJ10BACKGROUND ALARM SYSTEM OF ZXJ10

Training Center

Zhongxing Telecom Pakistan (Pvt.) Ltd

2

Once the Switching System Has Been Established and Put Into Operation, It Must Be Supervised So That Its Real Time Maintenance and Repair Can Be Done.

And All This Is Implemented by the Alarm Interface

NEED OF ALARM SYSTEM

3

Structure of the alarming system

LAN

Foregroundalarming system

Alarmingdevices

Backgroundserver

Client 1 Client 2 Client n

4

The main functions of the foreground alarming system of the switch

The main functions of the alarming system at the server end

The main functions of the client alarming system

The functions of the alarming system

5

Timely reflects the running state of the rack; Monitors the states of the slots on the rack and timely reports the

problems, if any, to the background alarming system; Processes the information sent by the environment monitoring board

and sends the processing result to the background alarming system; Executes background man-machine interface commands and returns

the execution results.

Foreground alarming system

6

Alarming system at the Server End(1/2)

Stores the history alarms; Stores the notification information; Stores the masking information; Stores the commissioning information; Stores the environment information;

7

Alarming system at the Server End(2/2)

Stores the configuration information; Guarantees the synchronization between the switch

foreground and the background client and forwards the messages from MP to the clients in time;

Processes various configuration commands from the clients;

Controls the alarm panel (optional).

8

Displays the latest alarm information in real time; Prints the latest alarm information instantly; Inquires and prints the current alarm contents; Inquires and prints the history alarm contents; Inquires and prints the notification information;

Client alarming system(1/2)

9

Client alarming system(2/2)

Sets and clears the alarm masking; Sets the environmental alarm conditions and starts and

closes the environmental alarm; Displays the rack diagram and the information about the

nodes at different levels; Displays the man-machine command operations and the

results; Controls the alarm panel (optional).

10

Mask alarm or de-mask alarm, setting conditions for environment alarm Real time display and instant printing of the latest alarm information Inquiry of present alarms and historic alarms and the content of notices

Instant printing of the results of all kinds of inquiries Dynamic display of rack figure Inquiry of the output of the interface commands.

Queries the interface command execution result

Functions of background alarm system

11

ALARMSThe alarms are usually failures that occur during the running of the switching system.They usually lasts for certain period of time and does not recover until the failure disappears. The operators can inquire according to the actual conditions.

There are four levels of alarms: major(1), serious(2), important(3) and

average(4).

SOME BASIC TERMS(1/2)

12

NOTICE They are some prompts during the running of the running of the

switch. They function to keep the operators informed with the running state of each part of the switch. They are not in levels and do not need any maintenance.

SOME BASIC TERMS(2/2)

13

After the alarm system is installed, the configuration of the alarm office should be conducted after that. This configuration program requires input of the Area code,Office number, The modules in the office, The number of each module,The rack number .The results of office configuration are saved in the database of the server.

The new configuration is valid only after the program in the alarm server is restarted.

ALARM OFFICE CONFIGURATION(1/4)

14

Now once the office has been configured

System Maintenance Alarm

Now the following window will appear.

ALARM OFFICE CONFIGURATION(2/4)

15

16

17

PAGE LAYOUT OF THE OFFICE NODE

Information Overview Information Inquiry Management of Database

PAGE LAYOUTS OF DIFFERENT NODES(1/4)

18

19

20

21

22

Red level 1 alarm.

Blue level 2 alarm.

Yellow level 3 alarm.

White level 4 alarm.

Kelly standby state.

Green active state.

Dark gray mask state.

Gray out-of-control state.

COLOURS FOR ALARMS

23

24

It enables the operator to inquire present alarms, historic alarms, and notices. The inquiry of alarms can be conducted according to the alarm level and alarm code, while the inquiry of the notices can be conducted according to notice code.

INFORMATION INQUIRY

25

To inquire the existing alarm of the present exchange

Select corresponding node in the office tree in the left part of the window. When an office node is selected, the information to be inquired is the information of all modules under this office node. When a place node is selected, the information to be inquired is that of all modules under this place. When a module node is selected, the information to be inquired is that of this module.

CURRENT ALARM INQUIRY

26

27

28

Historic alarm is an alarm that has happened before. The records of these alarms are saved in the database of the

alarm server.

HISTORIC ALARM INQUIRY

29

30

The inquiry of notice information is similar to that of historic alarm, only that this inquiry must be conducted

according to the notice code.

NOTICE INQUIRY

31

32

The alarm mask is divided into position mask and alarm code mask.

The alarm mask is closely related to the module, the mask is set in the “alarm setting” page in the module node.

ALARM MASK AND MASK REMOVAL(1/2)

33

34

The “masked alarm information presented during inquiry” in mask display setting box at the bottom of the interface enables the operator to choose to see the alarm mask information while the inquiry is conducted. When this option is selected, the masked alarm will display with the mark **.

ALARM MASK AND MASK REMOVAL(2/2)

35

36

37

When CPU occupation rate or resource occupation rate is too high, the switch does not present normal running. In order to avoid this, a valve value for the resource occupation rate can be set in the page “call restriction

management” to restrict calls

CALL RESTRICTION MANAGEMENT(1/2)

38

The vertical coordinates of the table indicates CPU occupation rate (%), the value ranging from 0 ~100. There are three valve values.

The horizontal coordinates of the table indicates resource occupation (%), the value ranging between 0~100. There are three valve values.

Both CPU occupation rate and resource occupation rate are divided into four sections. These two values combined to form five levels of call limitation: 0, 1, 2, 3, and 4(refer to call restriction table).

BHCA has four valve values and are divided into five sections, corresponding to five levels of call limitation.

CALL RESTRICTION MANAGEMENT(2/2)

39

40

“Management of database” can help inquire the size, the state, the records of the designated time period, and the earliest record time of the database. It can also be used to delete the records of the designated time period.

DATABASE MANAGMENT

41

42

Each board position of the “rack state diagram” is in fact a command button. When the state is not out-of-control, operations can be conducted on it, i.e. certain man-machine commands can be executed.

The man-machine commands have different levels. If the current user level is lower than the required level, the current operation can not be executed.

MAN MACHINE COMMANDS(1/2)

43

The man-machine commands are divided into the following types according to their functions .Some of them are:

Functional information inquiry Switchover between active and standby state Resetting Inquiry of state Switchover settings

MAN MACHINE COMMANDS(2/2)

44