ak-industries - english catalog

101
Linear displacement sensors

Upload: ak-industries

Post on 21-Mar-2016

294 views

Category:

Documents


5 download

DESCRIPTION

ak-industries - English catalog

TRANSCRIPT

Page 1: AK-Industries - English catalog

Linear displacement sensors

Page 2: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Selection guide

Model Measurement range Output Page

CD50

Up to 1250 mm

Potentiometer (1kΩ) 4 - 5

Analog (0…10V / 4…20mA / 0…20mA) 6 - 7

Incremental 8 - 9

CD60

Up to 1500 mm

Potentiometer (1kΩ) 10 - 11

Analog (0…10V / 4…20mA / 0…20mA) 12 - 13

Incremental 14 - 15

Absolute (SSI / Profibus / CANopen / DeviceNet) 16 - 17

CD80

Up to 2000 mm

Potentiometer (1kΩ) 18 - 19

Analog (0…10V / 4…20mA / 0…20mA) 20 – 21

Up to 2500 mm

Incremental 22 – 23

Absolute (SSI / Profibus / CANopen / DeviceNet) 24 - 25

Mechanical devices (MEC) 26 - 27

CD115

Up to 3000 mm

Potentiometer (1kΩ) 28 - 29

Analog (0…10V / 4…20mA / 0…20mA) 30 - 31

Up to 3500 mm

Incremental 32 - 33

Absolute (SSI / Profibus / CANopen / DeviceNet) 34 - 35

Mechanical devices (MEC) 36 - 37

CD150

Up to 6000 mm

Potentiometer (1kΩ) 38 - 39

Analog (0…10V / 4…20mA / 0…20mA) 40 - 41

Incremental 42 - 43

Absolute (SSI / Profibus / CANopen / DeviceNet) 44 - 45

Mechanical devices (MEC) 46 - 47

AS40

90° to 3600°

Potentiometer (1kΩ) 48 - 49

Analog (0…10V / 4…20mA / 0…20mA) 50 - 51

AS58

90° to 3600°

Potentiometer (1kΩ) 52 - 53

Analog (0…10V / 4…20mA / 0…20mA) 54 - 55

2

Page 3: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Selection guide

Model Measurement range Output Page

CDS1210

Up to 10 000 mm

Potentiometer (1kΩ) 56 - 57

Analog (0…10V / 4…20mA / 0…20mA) 58 – 59

Mechanical devices (MEC) 60 – 61

CD1215

Up to 15 000 mm

Potentiometer (1kΩ) 62 – 63

Analog (0…10V / 4…20mA / 0…20mA) 64 – 65

Mechanical devices (MEC) 66 – 67

CD1820

Up to 20 000 mm

Potentiometer (1kΩ) 68 - 69

Analog (0…10V / 4…20mA / 0…20mA) 70 – 71

Mechanical devices (MEC) 72 -73

CD1830

Up to 30 000 mm

Potentiometer (1kΩ) 74 - 75

Analog (0…10V / 4…20mA / 0…20mA) 76 - 77

Mechanical devices (MEC) 78 - 79

CD1840

Up to 40 000 mm

Potentiometer (1kΩ) 80 - 81

Analog (0…10V / 4…20mA / 0…20mA) 82 - 83

Mechanical devices (MEC) 84 - 85

CD1850

Up to 50 000 mm

Potentiometer (1kΩ) 86 - 87

Analog (0…10V / 4…20mA / 0…20mA) 88 - 89

Mechanical devices (MEC) 90 - 91

Output connections

Potentiometric version 84

Analog version 85

Incremental version 86

Options

For draw-wire sensors, CD series 87

For draw-wire sensors, CDS series 88

Adapter flanges for draw-wire sensors, MEC type 89

Accessories

Connectors 90

Mounting accessories 91

Accessories for optical encoders and angular sensors 92

3

Page 4: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD50 potentiometric output – Measurement range up to 1250 mm

Specifications:

Measurement range 0 up to 1250 mm

Output signal 1kΩ Potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,51 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires Cable forces:

Standard linearity +/- 0,25% f.s. – stroke ≤500mm

+/- 0,15% f.s. – stroke >500mm

+/- 0,10% f.s. – stroke >500mm (option)

Protection class IP54 (option IP67)

Max. Velocity 10 M/S

Max. Acceleration 40 M/S2 (before cable deformation)

Weight ≈ 700 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Ordering reference:

Model

CD50

Measurement range

0050 = 0 up to 50 mm

0100 = 0 up to 100 mm

0250 = 0 up to 250 mm

0500 = 0 up to 500 mm

0750 = 0 up to 750 mm

1000 = 0 up to 1000 mm

1200 = 0 up to 1200 mm

1250 = 0 up to 1250 mm

(Other range available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L25 = +/- 0.25% f.s. (standard for measuring range from 0 to 500mm)

L15 = +/- 0.15% f.s. (standard for measuring range greater than 500 mm)

(option for measuring range from 0 to 500mm)

L10 = +/- 0.10% f.s. (option for measuring range greater than 500 mm)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

RAC = Cable dust wiper

TEV = Water evacuation holes

Reference example: CD50-0750-R01R-L15-K02-OP-AC-EM

Measurement

range in mm Min. pull-out force Max. pull-out force

50 ≈ 6,40 N ≈ 6,50 N

100 ≈ 6,30 N ≈ 6,50 N

250 ≈ 6,00 N ≈ 6,50 N

500 ≈ 5,50 N ≈ 6,50 N

750 ≈ 5,00 N ≈ 6,50 N

1000 ≈ 4,50 N ≈ 6,50 N

1200 ≈ 4,00 N ≈ 6,50 N

1250 ≈ 4,00 N ≈ 6,50 N

CD50 OP

4

Page 5: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Dimensional drawing

5

Page 6: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD50 analog output – Measurement range 0 up to 1250 mm

Specifications:

Measurement range 0 up to 1250 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,51 mm

Detection element Multi-turn Hybrid potentiometer Cable forces:

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,25% f.s. – stroke ≤500mm

+/- 0,15% f.s. – stroke >500mm

+/- 0,10% f.s. – stroke >500mm (option)

Protection class IP54 (option IP67)

Max. Velocity 10 M/S

Max. Acceleration 40 M/S2 (before cable deformation)

Weight ≈ 700 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Ordering reference:

Model

CD50

Measurement range

0050 = 0 up to 50 mm

0100 = 0 up to 100 mm

0250 = 0 up to 250 mm

0500 = 0 up to 500 mm

0750 = 0 up to 750 mm

1000 = 0 up to 1000 mm

1200 = 0 up to 1200 mm

1250 = 0 up to 1250 mm

(Other range available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L25 = +/- 0.25% f.s. (standard for measuring range from 0 up to 500mm)

L15 = +/- 0.15% f.s. (standard for measuring range greater than 500 mm)

(option for measuring range from 0 up to 500mm)

L10 = +/- 0.10% f.s. (option for measuring range greater than 500 mm)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

RAC = Cable dust wiper

TEV = Water evacuation holes

Reference example: CD50-0750-U010-L15-K02-OP-AC-EM

Measurement

range in mm Min. pull-out force Max. pull-out force

50 ≈ 6,40 N ≈ 6,50 N

100 ≈ 6,30 N ≈ 6,50 N

250 ≈ 6,00 N ≈ 6,50 N

500 ≈ 5,50 N ≈ 6,50 N

750 ≈ 5,00 N ≈ 6,50 N

1000 ≈ 4,50 N ≈ 6,50 N

1200 ≈ 4,00 N ≈ 6,50 N

1250 ≈ 4,00 N ≈ 6,50 N

CD50 OP

6

Page 7: AK-Industries - English catalog

20

1530

40

1104

9

60

2

,50

3

0

14,50

2 x 4,50

5

1

2,5

0

30

,50

11

0

70

3

4,5

0

49

49

18 6,50

6

7

5,5

0

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

K Connection(PVC cable - 4 wires)

L4 connection (connector M12 - 4 pin)

C connection(Connector M16 - DIN 8 pin )

1

7,5

0

7

Page 8: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD50 incremental output - Measurement range 0 to 1250 mm

Specifications:

Measurement range 0 up to 1250 mm

Sensing device Incremental encoder

Supply and output signal 2G2 (5Vdc – Driver 5Vdc RS422)

5G5 (11 to 30Vdc – Push-pull)

9G5 (5 to 24Vdc – Push-pull)

PG5 (5 to 30Vdc – Push-pull)

Resolution 1 – 5 – 10 – 20 or 25 pulses per mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,51 mm

Connection Male connector M16 – DIN 8 pin

Male connector M16 – DIN 5 pin

PVC cable – 8 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 Cable forces:

Max. Velocity 10 M/S

Max. Acceleration 40 M/S2 (before cable deformation)

Weight ≈ 700 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Ordering reference:

Model

CD50

Measurement range

1250 = 0 à 1250 mm

(Or other ranges between 0 and 1250 mm)

Resolution

01 = 1 pulses per mm

05 = 5 pulses per mm

10 = 10 pulses per mm

20 = 20 pulses per mm

25 = 25 pulses per mm

(Other range available on demand)

Supply and output stage

2G2 = 5Vdc – Driver 5Vdc RS422

5G5 = 11 to 30Vdc – Push-pull

9G5 = 5 to 24Vdc – Push-pull

PG5 = 5 to 30Vdc – Push-pull

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

GDA = Male connector M16 – DIN 8 pin

G2A = Male connector M16 – DIN 5 pin

G3R = PVC cable - 8 wires - radial + ex: 020 for cable 2 meters long

G3A = PVC cable - 8 wires - axial + ex: 020 for cable 2 meters long

OP options

AC = Complete anodizing

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

M4 = Fixing of the measuring cable with a M4 threaded rod

RAC = Cable dust wiper

TEV = Water evacuation holes

Reference example: CD50-1250-05-PG5-L05-GDA-OP-AC-EM

Measurement

range in mm Min. pull-out force

Max. pull-out

force

1250 ≈ 4,00 N ≈ 6,50 N

CD50 OP

8

Page 9: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Dimensional drawing

9

Page 10: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD60 potentiometric output – Measurement range 0 up to 1500 mm

Specifications:

Measurement range 0 up to 1500 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 m/s

Max. Acceleration 20 m/s2 (before cable deformation)

Weight ≈ 1000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD60

Measurement range

1500 = 0 up to 1500 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD60-1500-R01K-L15-K02-OP-AC-EM

Measurement

range in mm Min. pull-out force Max. pull-out force

1500 ≈ 9,00 N ≈ 12,00 N

CD60 OP

10

Page 11: AK-Industries - English catalog

(connector M12 - 4 pin)L4 connection

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 3 pin )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

58

59

60 19

161

59

18 6,50

3

4,5

0

5

9

9

7,5

0

8

1

32

90

4

,75

76 7

2

3,7

5

4

2

2

15,50

4 x 6,50

11

,50

2

0

1

6,5

0

11

Page 12: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD60 analog output – Measurement range 0 up to 1500 mm

Specifications:

Measurement range 0 up to 1500 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 m/s

Max. Acceleration 20 m/s2 (before cable deformation)

Weight ≈ 1000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD60

Measurement range

1500 = 0 up to 1500 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD60-1500-U010-L15-K02-OP-AC-EM

Measurement

range in mm Min. pull-out force Max. pull-out force

1500 ≈ 9,00 N ≈ 12,00 N

CD60 OP

12

Page 13: AK-Industries - English catalog

1

6,5

0

K connection(PVC cable - 4 wires)

2

0

6,50 4 x

76 7

2

3,7

5

4

2

2

15,50

1

1,5

0

4

,75

18 6,50

3

4,5

0

59

5

9

9

7,5

0

8

1

32

90

58

59

60 19

161

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

(connector M12 - 4 pin)L4 connection

C connection(Connector M16 - DIN 8 pin )

13

Page 14: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD60 incremental output - Measurement range 0 up to 1500 mm Specifications:

Measurement range 0 up to 1500 mm

Sensing device Incremental encoder

Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)

PG5 (5 to 30Vdc - Push-pull 5-30Vdc)

RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)

5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)

Resolution 1 - 5 - 10 - 20 or 25 pulses per mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

PUR cable – 12 wires

PVC cable – 8 wires

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Protection class IP64 Cable forces:

Max. Velocity 10 M/S

Max. Acceleration 20 M/S2 (before cable deformation)

Weight ≈ 1000 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD60

Measurement range

1500 = 0 to 1500 mm

(Other ranges available on demand)

Resolution

01 = 1 pulses per mm

05 = 5 pulses per mm

10 = 10 pulses per mm

20 = 20 pulses per mm

25 = 25 pulses per mm

(Other values on demand)

Supply and output stage

2G2 = 5Vdc - Driver 5Vdc RS422

PG5 = 5 to 30Vdc - Push-pull 5-30Vdc

RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422

5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

G6R = Male connector M23 – 12 pin CW

G8R = Male connector M23 – 12 pin CCW

GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long

G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD60-1500-05-PG5-L05-G6R-OP-AC-EM

Measurement

range in mm Min. pull-out force

Max. pull-out

force

1500 ≈ 9,00 N ≈ 12,00 N

CD60 OP

14

Page 15: AK-Industries - English catalog

54 52,50

19

106,50

119,41

59

60

5

8,5

0

1

32

6,50

59

90

18

3

4,5

0

5

9

9

7,5

0

8

3

7,5

0

15,50

6,50

2

76

4 x

7

4

2

2

3,7

5

4

,75

4

0,7

5

4

0,7

5

With DHM5 encoderG6R or G8R connection

(Male connector M23 - 12 pin CW or CCW)

With DHM5 encoderGPR or G3R connection

(PUR cable - 12 wires or PVC cable - 8 wires )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 15

Page 16: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD60 absolute output - Measurement range 0 up to 1500 mm Specifications:

Measurement range 0 up to 1500 mm

Sensing device Absolute encoder (PHM5 or MHM5 series)

Supply 10 - 30Vdc (MHM5)

5 - 30Vdc (PHM5)

Interface SSI

Profibus

CANopen

DeviceNet

Resolution 13 bits = 8192steps/turns

Distance per turns 150 mm

152,4 mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

Terminal box

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Protection class IP64 Cable forces:

Max. Velocity 10 m/s

Max. Acceleration 20 m/s² (before cable deformation)

Weight ≈ 1000 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD60

Measurement range

1500 = 0 to 1500 mm

(Other ranges available on demand)

Distance per turns

150 = 150 mm

152 = 152,4 mm

Interface

SSI/1 = MHM5 Serial transmission (SSI)

SSI/2 = PHM5 Serial transmission (SSI)

PROF = MHM5 Profibus transmission

CAN = MHM5 CANopen transmission

DEV = MHM5 DeviceNet transmission

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

H3P = Terminal box (only for MHM5 Profibus and CANopen)

0CC = Terminal box (only for MHM5 DeviceNet)

PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)

S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)

S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

EN = Measuring cable coated with polyamide

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD60-1500-152-PROF-L05-H3P-OP-AC-EM

Measurement

range in mm Min. pull-out force

Max. pull-out

force

1500 ≈ 9,00 N ≈ 12,00 N

CD60 OP

16

Page 17: AK-Industries - English catalog

1

7,5

0

2

0

2

0

58,50

94

,25

ve

rsio

n 0

CC

79

,75

ve

rsio

n H

3P

51

4

8,7

5

72,20

3

9,7

5

(Male connector M23 - 12 pin CW or CCW)S6R or S8R connection

With PHM5 - SSI encoder

(Male connector M23 - 12 pin CCW)PRL connection

With MHM5 - SSI encoder

With MHM5 - PROF/CANO/DNET encoder0CC or H3P connection

(Terminal box)

60

59

19

175 version 0CC

160 version H3P

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

8

59

6,50 18

3

4,5

0

9

7,5

0

5

9

1

32

90

15,50

6,50 4 x

76 7

2

3,7

5

4

2

2

4,7

5

1

36

1

24

,50

17

Page 18: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD80 potentiometric output – Measurement range 0 up to 2000 mm

Specifications:

Measurement range 0 up to 2000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 m/s

Max. Acceleration 8 m/s2 (before cable deformation)

Weight ≈ 1500 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD80

Measurement range

2000 = 0 up to 2000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD80-2000-R01K-L15-K02-OP-AC-EM

Measurement

range in mm Min. pull-out force Max. pull-out force

2000 ≈ 8,00 N ≈ 11,00 N

CD80 OP

18

Page 19: AK-Industries - English catalog

K connection(PVC cable - 4 wires)

L4 connection(connector M12 - 4 pin)

C connection(Connector M16 - DIN 3 pin )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

58

161

50

59

29,50

18

7

9

1

52

6,50

3

4,5

0

120

1

17

,50

8

79

10

18,50

9

100

5

4,5

0

2 x

2

5

6,50

11

,50

2

0

1

6,5

0

19

Page 20: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD80 analog output – Measurement range 0 up to 2000 mm

Specifications:

Measurement range 0 up to 2000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 m/s

Max. Acceleration 8 m/s2 (before cable deformation)

Weight ≈ 1500 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD80

Measurement range

2000 = 0 up to 2000 mm

(Other range available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD80-2000-U010-L15-K02-OP-AC-EM

Measurement

range in mm Min. pull-out force Max. pull-out force

2000 ≈ 8,00 N ≈ 11,00 N

CD80 OP

20

Page 21: AK-Industries - English catalog

1

6,5

0

2

0

6,50 2 x

9

100

5

4,5

0

2

5

10

18,50

1

1,5

0

3

4,5

0

18 6,50

1

52

79

120

1

17

,50

8

79

58

161

50

59

29,50

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

K connection(PVC cable - 4 wires)

L4 connection(connector M12 - 4 pin)

C connection(Connector M16 - DIN 8 pin )

21

Page 22: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD80 incremental output - Measurement range 0 up to 2500 mm

Specifications:

Measurement range 0 up to 2500 mm

Sensing device Incremental encoder

Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)

PG5 (5 to 30Vdc - Push-pull 5-30Vdc)

RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)

5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)

Resolution 1 - 5 - 10 - 20 or 25 pulses per mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

PUR cable - 12 wires

PVC cable - 8 wires

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Protection class IP64 Cable forces:

Max. Velocity 10 m/s

Max. Acceleration 8 m/s2 (before cable deformation)

Weight ≈ 1500 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD80

Measurement range

2500 = 0 up to 2500 mm

(Other ranges available on demand)

Resolution

01 = 1 pulses per mm

05 = 5 pulses per mm

10 = 10 pulses per mm

20 = 20 pulses per mm

25 = 25 pulses per mm

(Other values on-demand)

Supply and output stage

2G2 = 5Vdc - Driver 5Vdc RS422

PG5 = 5 to 30Vdc - Push-pull 5-30Vdc

RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422

5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

G6R = Male connector M23 – 12 pin CW

G8R = Male connector M23 – 12 pin CCW

GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long

G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD80-2500-05-PG5-L05-G6R-OP-AC-EM

Measurement

range in mm Min. pull-out force

Max. pull-out

force

2500 ≈ 7,50 N ≈ 11,00 N

CD80 OP

22

Page 23: AK-Industries - English catalog

52,50

5

1

54

18,50

10

6,50

100

9

5

4,5

0

2

5 2 x

5

2

3

4,5

0

4

7,5

0

6,50

7

9

18

1

52

120

1

17

,50

8

79

59

29,50

119,40

50

106,50

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

With DHM5 encoderGPR or G3R connection

(PUR cable - 12 wires or PVC cable - 8 wires )

With DHM5 encoderG6R or G8R connection

(Male connector M23 - 12 pin CW or CCW)

23

Page 24: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD80 absolute output - Measurement range 0 up to 2500 mm Specifications:

Measurement range 0 up to 2500 mm

Sensing device Absolute encoder (PHM5 or MHM5 series)

Supply 10 - 30Vdc (MHM5)

5 - 30Vdc (PHM5)

Interface SSI

Profibus

CANopen

DeviceNet

Resolution 13 bits = 8192steps/turns

Distance per turns 200 mm

204,8 mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

Terminal box

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Protection class IP64 Cable forces:

Max. Velocity 10 m/s

Max. Acceleration 8 m/s2 (before cable deformation)

Weight ≈ 1500 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD80

Measurement range

2500 = 0 à 2500 mm

(Other ranges available on demand)

Distance per turns

200 = 200 mm

204 = 204,8 mm

Interface

SSI/1 = MHM5 Serial transmission (SSI)

SSI/2 = PHM5 Serial transmission (SSI)

PROF = MHM5 Profibus transmission

CAN = MHM5 CANopen transmission

DEV = MHM5 DeviceNet transmission

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

H3P = Terminal box (only for MHM5 Profibus and CANopen)

0CC = Terminal box (only for MHM5 DeviceNet)

PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)

S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)

S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD80-2500-204-PROF-L05-H3P-OP-AC-EM

Measurement

range in mm Min. pull-out force

Max. pull-out

force

2500 ≈ 7,50 N ≈ 11,00 N

CD80 OP

24

Page 25: AK-Industries - English catalog

72,20

5

1

58,50

10

5,5

0 v

ers

ion

0C

C

91

ve

rsio

n H

3P

51

6

0

2

0

2

0

2

7,5

0

1

24

,50

2

5

18,50

10 100

9

5

4,5

0

2 x 6,50

1

36

1

17

,50

6,50 18

79

1

52

3

4,5

0

120

8

79

(Male connector M23 - 12 pin CCW)PRL connection

With MHM5 - SSI encoderS6R or S8R connection

With PHM5 - SSI encoder

(Male connector M23 - 12 pin CW or CCW)

With MHM5 - PROF/CANO/DNET encoderH3P or 0CC connection

(Terminal box)

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

50 29,50

59

175 version 0CC

160 version H3P

25

Page 26: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD80-MEC mechanical devices - Measurement range 0 up to 2500 mm

Specifications:

Measurement range 0 up to 2500 mm

Circumference drum 200 mm/turn

204,8 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 8 m/s2 (before cable deformation)

Weight ≈ 1500 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD80-MEC

Measurement range

2500 = 0 up to 2500 mm

(Other range available on demand)

Drum circumference

200 = 200 mm/turn

204 = 204,8 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

EM = Fixing of the measuring cable with a clip

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CD80-MEC-2500-200-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

2500 ≈ 7,50 N ≈ 11,00 N

CD80 MEC OP

26

Page 27: AK-Industries - English catalog

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

29,50 50

59

127,40

Oldham coupling adaptable to the detection element that

will be mounted (see options)

7

9

18 6,50

1

52

120

1

17

,50

34

,50

4

7,5

0

8

50 ++

0,050,02

79

100

9

5

4,5

0

2

5

10

18,50

2 x 6,50

27

Page 28: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD115 potentiometric output – Measurement range 0 up to 3000 mm

Specifications:

Measurement range 0 up to 3000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10m/s

Max. Acceleration 7 m/s2 (before cable deformation)

Weight ≈ 2000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD115

Measurement range

3000 = 0 up to 3000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

BR = Cleaning brush for the cable

Reference example: CD115-3000-R01K-L15-K02-OP-AC-M4

Measurement

range in mm Min. pull-out force Max. pull-out force

3000 ≈ 13,50 N ≈ 18,00 N

CD115 OP

28

Page 29: AK-Industries - English catalog

115

1

88

3

4,5

0

1

53

,50

155

8

18 6,50

1

15

6

5,5

0

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

(connector M12 - 4 pin)L4 connection

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 3 pin )

89

50 31

162

5

8

2 x

5

6

6,50

2

5

7

,50

20,50

10 135

1

1,5

0

1

6,5

0

2

0

29

Page 30: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD115 analog output – Measurement range 0 up to 3000 mm

Specifications:

Measurement range 0 up to 3000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,61 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 M/S

Max. Acceleration 7 M/S2 (before cable deformation)

Weight ≈ 2000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD115

Measurement range

3000 = 0 up to 3000 mm

(Other range available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD115-3000-U010-L15-K02-OP-AC-M4

Measurement

range in mm Min. pull-out force Max. pull-out force

3000 ≈ 13,50 N ≈ 18,00 N

CD115 OP

30

Page 31: AK-Industries - English catalog

1

6,5

0

6,50 2 x

135

5

6

2

5

10

7

,50

20,50

1

1,5

0

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

6,50 18

1

15

1

88

155

3

4,5

0

115

1

53

,50

8

6

5,5

0

89

162

50 31

5

8

(connector M12 - 4 pin)L4 connection

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 8 pin )

2

0

31

Page 32: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD115 incremental output - Measurement range 0 up to 3500 mm

Specifications:

Measurement range 0 up to 3500 mm

Sensing device Incremental encoder

Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)

PG5 (5 to 30Vdc - Push-pull 5-30Vdc)

RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)

5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)

Resolution 1 - 5 - 10 - 20 or 25 pulses per mm

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

PUR cable – 12 wires

PVC cable – 8 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65 Cable forces:

Max. Velocity 10 m/s

Max. Acceleration 7 m/s2 (before cable deformation)

Weight ≈ 2000 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD115

Measurement range

3500 = 0 up to 3500 mm

(Other ranges available on demand)

Resolution

01 = 1 pulses per mm

05 = 5 pulses per mm

10 = 10 pulses per mm

20 = 20 pulses per mm

25 = 25 pulses per mm

(Other values on demand)

Supply and output stage

2G2 = 5Vdc - Driver 5Vdc RS422

PG5 = 5 to 30Vdc - Push-pull 5-30Vdc

RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422

5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

G6R = Male connector M23 – 12 pin CW

G8R = Male connector M23 – 12 pin CCW

GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long

G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD115-3500-05-PG5-L05-G6R-OP-AC-M4

Measurement

range in mm Min. pull-out force

Max. pull-out

force

3500 ≈ 13,00 N ≈ 18,00 N

CD115 OP

32

Page 33: AK-Industries - English catalog

52,50

5

1,5

0

54

6,50

20,50

135

5

6

2

5 2 x

7

,50

10

5

1,5

0

50 31

89

120,50

6,50

1

15

18

1

88

155

3

4,5

0

115

1

53

,50

8

6

5,5

0

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

With DHM5 encoder

(PUR cable - 12 wires or PVC cable - 8 wires )GPR or G3R connection

With DHM5 encoderG6R or G8R connection

(Male connector M23 - 12 pin CW or CCW)

33

Page 34: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD115 absolute output - Measurement range 0 up to 3500 mm

Specifications:

Measurement range 0 up to 3500 mm

Sensing device Absolute encoder (PHM5 or MHM5 series)

Supply 10 - 30Vdc (MHM5)

5 - 30Vdc (PHM5)

Interface SSI

Profibus

CANopen

DeviceNet

Resolution 13 bits = 8192steps/turns

Distance per turns 300 mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

Terminal box

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Protection class IP64 Cable forces:

Max. Velocity 10 M/S

Max. Acceleration 7 M/S2 (before cable deformation)

Weight ≈ 2000 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD115

Measurement range

3500 = 0 à 3500 mm

(Other range available on demand)

Distance per turns

300 = 300 mm

Interface

SSI/1 = MHM5 Serial transmission (SSI)

SSI/2 = PHM5 Serial transmission (SSI)

PROF = MHM5 Profibus transmission

CAN = MHM5 CANopen transmission

DEV = MHM5 DeviceNet transmission

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

H3P = Terminal box (only for MHM5 Profibus and CANopen)

0CC = Terminal box (only for MHM5 DeviceNet)

PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)

S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)

S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD115-3500-300-PROF-L05-H3P-OP-AC-M4

Measurement

range in mm Min. pull-out force

Max. pull-out

force

3500 ≈ 13,00 N ≈ 18,00 N

CD115 OP

34

Page 35: AK-Industries - English catalog

2

0

4

5,5

0

2

0

51

5

9,5

0

58,50

10

5 v

ers

ion

0C

C

90

,50

ve

rsio

n H

3P

5

1

72,20

161 version H3P

50

89

31

176 version 0CC

6

0

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

6,50 18

1

88

3

4,5

0

1

53

,50

1

15

155

8

115

(Male connector M23 - 12 pin CW or CCW)S6R or S8R connection

With PHM5 - SSI encoderPRL connection

(Male connector M23 - 12 pin CCW)

With MHM5 - SSI encoder

With MHM5 - PROF/CANO/DNET encoder0CC or H3P connection

(Terminal box)

1

37

6,50

20,50

7

,50

5

6

2 x

25

10 135

1

25

,50

35

Page 36: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD115-MEC mechanical devices - Measurement range 0 up to 3500 mm

Specifications:

Measurement range 0 up to 3500 mm

Circumference drum 300 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 7 m/s2 (before cable deformation)

Weight ≈ 2000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD115-MEC

Measurement range

3500 = 0 up to 3500 mm

(Other ranges available on demand)

Drum circumference

300 = 300 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CD115-MEC-3500-300-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

3500 ≈ 13,00 N ≈ 18,00 N

CD115 MEC OP

36

Page 37: AK-Industries - English catalog

6,50

7

,50

2 x

20,50

5

6

2

5

10 135

128,40

50 31

8

9

Oldham coupling adaptable to the detection element that

will be mounted (see options)

8

0,02

18

155

0,05

3

4,5

0

6

5,5

0

1

53

,50

1

15

1

88

115

50 ++

6,50

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 37

Page 38: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD150 potentiometric output – Measurement range 0 up to 6000 mm

Specifications:

Measurement range 0 up to 6000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 m/s

Max. Acceleration 5 m/s2 (before cable deformation)

Weight ≈ 3000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD150

Measurement range

4000 = 0 up to 4000 mm

6000 = 0 up to 6000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD150-4000-R01K-L15-K02-OP-AC-M4

Measurement

range in mm Min. pull-out force Max. pull-out force

4000 ≈ 11,00 N ≈ 13,50 N

6000 ≈ 10,00 N ≈ 13,50 N

CD150 OP

38

Page 39: AK-Industries - English catalog

(connector M12 - 4 pin)

)C connection

(Connector M16 - DIN 3 pinL4 connection

Measurement range up to 4000 mm

6,50

186

148

1

48

1

86

,50

3

4,5

0

8

2

21

18

8

2

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

6,50 4 x

170 8

4

4

8

3

8,2

5

1

2,2

5

20,25

1

1,5

0

171,50

30,25

89

60

58

K connection(PVC cable - 4 wires)

K connection(PVC cable - 4 wires)

2

0

L4 connection(connector M12 - 4 pin)

1

6,5

0

1

6,5

0

20,25

170 8

4 x 6,50

3

8,2

5

8

4

4

1

2,2

5

1

1,5

0

C connection(Connector M16 - DIN 3 pin )

6,50

186

148

1

48

1

86

,50

8

2

21

3

4,5

0

18

1

08

60

89

12

0

138

30,25

Measuring range greater than 4000 mm up to 6000 mm

2

0

39

Page 40: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD150 analog output – Measurement range 0 up to 6000 mm

Specifications:

Measurement range 0 up to 6000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP54 (option IP67)

Max. Velocity 10 m/s

Max. Acceleration 5 m/s2 (before cable deformation)

Weight ≈ 3000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD150

Measurement range

4000 = 0 up to 4000 mm

6000 = 0 up to 6000 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD150-4000-U010-L15-K02-OP-AC-M4

Measurement

range in mm Min. pull-out force Max. pull-out force

4000 ≈ 11,00 N ≈ 13,50 N

6000 ≈ 10,00 N ≈ 13,50 N

CD150 OP

40

Page 41: AK-Industries - English catalog

8

4

4

1

2,2

5

1

1,5

0

170 8

4 x 6,50

3

8,2

5

20,25

1

6,5

0

20

K connection(PVC cable - 4 wires)

K connection(PVC cable - 4 wires)

2

0

1

6,5

0

20,25

6,50

170

4 x

4

4

8

8

3

8,2

5

1

2,2

5

1

1,5

0

6,50

186

148

1

48

1

86

,50

18

8

3

4,5

0

2

21

8

2

30,25

89

171,50

60

5

8

3

4,5

0

186

1

08

148

1

48

18

1

86

,50

8

2

21

6,50

89

138

60

12

0

30,25

)

C connection(Connector M16 - DIN 8 pin

Measurement range up to 4000 mm

L4 connection(connector M12 - 4 pin)

(connector M12 - 4 pin)L4 connection

)

C connection(Connector M16 - DIN 8 pin

Measuring range greater than 4000 mm up to 6000 mm

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 41

Page 42: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD150 incremental output - Measurement range 0 up to 6000 mm

Specifications:

Measurement range 0 up to 6000 mm

Sensing device Incremental encoder

Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)

PG5 (5 to 30Vdc - Push-pull 5-30Vdc)

RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)

5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)

Resolution 1 - 5 - 10 - 20 or 25 pulses per mm

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

12-wires PUR cable

8-wires PVC cable

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65 Cable forces:

Max. Velocity 10 M/S

Max. Acceleration 5 M/S2 (before cable deformation)

Weight ≈ 3000 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD150

Measurement range

6000 = 0 up to 6000 mm

(Other ranges available on demand)

Resolution

01 = 1 pulses per mm

05 = 5 pulses per mm

10 = 10 pulses per mm

20 = 20 pulses per mm

25 = 25 pulses per mm

(Other values on demand)

Supply and output stage

2G2 = 5Vdc - Driver 5Vdc RS422

PG5 = 5 to 30Vdc - Push-pull 5-30Vdc

RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422

5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

G6R = Male connector M23 – 12 pin CW

G8R = Male connector M23 – 12 pin CCW

GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long

G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD150-6000-05-PG5-L05-G6R-OP-AC-M4

Measurement

range in mm Min. pull-out force

Max. pull-out

force

6000 ≈ 10,00 N ≈ 13,50 N

CD150 OP

42

Page 43: AK-Industries - English catalog

130

52,50

3

4,7

5

54

58

,50

89

60 30,25 148

186

8

2

1

48

1

86

,50

18

8

2

21

3

4,5

0

6,50

170

12

,25

20,25

3

4,7

5

4

4

8

8

3

8,2

5

4 x 6,50

With DHM5 encoder

(Male connector M23 - 12 pin CW or CCW)G6R or G8R connection

With DHM5 encoderGPR or G3R connection

(PUR cable - 12 wires or PVC cable - 8 wires )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 43

Page 44: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD150 absolute output - Measurement range 0 up to 6000 mm

Specifications:

Measurement range 0 up to 6000 mm

Sensing device Absolute encoder (PHM5 or MHM5 series)

Supply 10 - 30Vdc (MHM5)

5 - 30Vdc (PHM5)

Interface SSI

Profibus

CANopen

DeviceNet

Resolution 13 bits = 8192steps/turns

Distance per turns 409,6 mm

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Connection Male connector M23 – 12 pin CW

Male connector M23 – 12 pin CCW

Terminal box

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Protection class IP64 Cable forces:

Max. Velocity 10 M/S

Max. Acceleration 5 M/S2 (before cable deformation)

Weight ≈ 3000 g

Operating temperature -20° to +85°C

Storage temperature -40° to +85°C

Ordering reference:

Model

CD150

Measurement range

6000 = 0 à 6000 mm

(Other ranges available on demand)

Distance per turns

409 = 409,6 mm

Interface

SSI/1 = MHM5 Serial transmission (SSI)

SSI/2 = PHM5 Serial transmission (SSI)

PROF = MHM5 Profibus transmission

CAN = MHM5 CANopen transmission

DEV = MHM5 DeviceNet transmission

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

Connection

H3P = Terminal box (only for MHM5 Profibus and CANopen)

0CC = Terminal box (only for MHM5 DeviceNet)

PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)

S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)

S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)

OP options

AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

Reference example: CD150-6000-409-PROF-L05-H3P-OP-AC-M4

Measurement

range in mm Min. pull-out force

Max. pull-out

force

6000 ≈ 10,00 N ≈ 13,50 N

CD150 OP

44

Page 45: AK-Industries - English catalog

6

2

2

0

20

8

8,2

5 v

ers

ion

0C

C

73

,75

ve

rsio

n H

3P

4

2,7

5

51 72,20

3

3,5

0

(Male connector M23 - 12 pin CCW)

With MHM5 - SSI encoderPRL connection

(Male connector M23 - 12 pin CW or CCW)S6R or S8R connection

With PHM5 - SSI encoderWith MHM5 - PROF/CANO/DNET encoder

0CC or H3P connection(Terminal box)

186

148

2

21

1

48

1

86

,50

18

8

3

4,5

0

6,50 Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

1

2,2

5

20,25

170

4

4

8

8

3

8,2

5

4 x 6,50

6

0

89

60 30,25

185,50 version 0CC

170,50 version H3P

1

46

,50

1

35

45

Page 46: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD150-MEC mechanical devices - Measurement range 0 up to 6000 mm

Specifications:

Measurement range 0 up to 6000 mm

Circumference drum 409,6 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,60 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 5 m/s2 (before cable deformation)

Weight ≈ 3000 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CD150-MEC

Measurement range

6000 = 0 up to 6000 mm

(Other ranges available on demand)

Drum circumference

409 = 409,6 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

CP = Fixing of the measuring cable with a clevis

M4 = Fixing of the measuring cable with a M4 threaded rod

TEV = Water evacuation holes

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CD150-MEC-6000-409-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

6000 ≈ 10,00 N ≈ 13,50 N

CD150 MEC OP

46

Page 47: AK-Industries - English catalog

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

78

89

60 30,25

137,90

Oldham coupling adaptable to the detection element that

will be mounted (see options)

8

2

186

1

86

,50

34

,50

8

2

21

18 6,50

1

48

148

50 ++

0,050,02

170

20,25

8

4

4

8

3

8,2

5

1

2,2

5

4 x 6,50

47

Page 48: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1210 potentiometric output – Measurement range 0 up to 10 000 mm

Specifications:

Measurement range 0 up to 10 000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 3 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 5 m/s2 (before cable deformation)

Weight ≈ 6 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1210

Measurement range

10000 = 0 up to 10 000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 3 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1210-10000-R01K-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

10 000 ≈ 10,50 N ≈ 15,00 N

CDS1210 OP

48

Page 49: AK-Industries - English catalog

11,50

1

72

,50

Modular base plate

)

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 3 pin

L4 connection(connector M12 - 4 pin)

1

6,5

0

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

102

12

0

216

12

0

66

1

0

30

20,20

4

0

6

0

115

1

8,5

0

8

4,5

0

10

9

3

0

47

1

1,5

0

40,50

120

135

1

28

1

14

8

9

4

2

0

6

8

26

1

32

49

Page 50: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD1210 analog output – Measurement range 0 up to 10 000 mm

Specifications:

Measurement range 0 up to 10 000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 8 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 M/S

Max. Acceleration 5 M/S2 (before cable deformation)

Weight ≈ 6 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1210

Measurement range

10000 = 0 up to 10 000 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 8 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1210-10000-U010-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

10 000 ≈ 11,00 N ≈ 13,50 N

CDS1210 OP

50

Page 51: AK-Industries - English catalog

11,50

1

72

,50

(connector M12 - 4 pin)

Modular base plate

L4 connection(PVC cable - 4 wires)

K connection C connection(Connector M16 - DIN 8 pin )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

216

102

12

0

12

0

66

1

14

135

120

1

28

9

4

8

10

30

20,20

4

0

6

0

115

1

8,5

0

8

4,5

0

1

1,5

0

10

9

3

0

47

40,50

1

6,5

0

2

0

26

6

8

1

30

,50

51

Page 52: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1210-MEC mechanical devices - Measurement range 0 up to 10 000 mm

Specifications:

Measurement range 0 up to 10 000 mm

Circumference drum 300 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable – Stainless steel

Cable diameter 0,90 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 5 m/s2 (before cable deformation)

Weight ≈ 6kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1210-MEC

Measurement range

10000 = 0 up to 10 000 mm

(Other ranges available on demand)

Drum circumference

300 = 300 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CDS1210-MEC-10000-300-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

10 000 ≈ 10,50 N ≈ 15,00 N

CDS1210 MEC OP

52

Page 53: AK-Industries - English catalog

1

72

,50

11,50

6

8

1

32

3

0

10

47

20,20

4

0

30

6

0

115

1

8,5

0

8

4,5

0

9

1

0

40,50

Oldham coupling adaptable to the detection element that

will be mounted (see options)

6

8

135

120

8

1

28

1

14

50 ++

0,050,02

102 66

12

0

181

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

Modular base plate

53

Page 54: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1215 potentiometric output – Measurement range 0 up to 15 000 mm

Specifications:

Measurement range 0 up to 15 000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 3 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 4 m/s2 (before cable deformation)

Weight ≈ 8 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1215

Measurement range

15000 = 0 up to 15 000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 3 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1215-15000-R01K-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

15 000 ≈ 10,50 N ≈ 15,00 N

CDS1215 OP

54

Page 55: AK-Industries - English catalog

1

72

,50

11,50

L4 connection(connector M12 - 4 pin)(PVC cable - 4 wires)

K connection

C connection(Connector M16 - DIN 3 pin )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

120

135

1

28

1

14

8

9

4

12

0

311,50

137,50

128

1

20

1

80

,50

5

2,5

0

4

0

6

0

1

1,5

0

9

20,20

30

3

0

47

10 115

1

0

40,50

1

6,5

0

Modular base plate

2

0

6

8

26

1

32

55

Page 56: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD1215 analog output – Measurement range 0 up to 15 000 mm

Specifications:

Measurement range 0 up to 15 000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 8 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 4 m/s2 (before cable deformation)

Weight ≈ 8 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1215

Measurement range

15000 = 0 up to 15 000 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 8 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1215-15000-U010-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

15 000 ≈ 10,50 N ≈ 15,00 N

CDS1215 OP

56

Page 57: AK-Industries - English catalog

1

72

,50

11,50

(connector M12 - 4 pin)L4 connection )

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 8 pin

Modular base plate

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

1

28

135

1

14

120

8

9

4

311,50

137,50 128

12

0

1

20

1

80

,50

5

2,5

0

4

0

6

0

9

20,20

30

3

0

47

10 115

1

1,5

0

1

0

40,50

1

6,5

0

2

0

6

8

26

1

32

57

Page 58: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1215-MEC mechanical devices - Measurement range 0 up to 15 000 mm

Specifications:

Measurement range 0 up to 15 000 mm

Circumference drum 300 mm/turn

Sensing device Adaptable with all of our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 4 m/s² (before cable deformation)

Weight ≈ 8kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1215-MEC

Measurement range

15000 = 0 up to 15 000 mm

(Other ranges available on demand)

Drum circumference

300 = 300 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CDS1215-MEC-15000-300-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

15 000 ≈ 10,50 N ≈ 15,00 N

CDS1215 MEC OP

58

Page 59: AK-Industries - English catalog

1

72

,50

11,50

Modular base plate

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

Oldham coupling adaptable to the detection element that

will be mounted (see options)

135

6

8

8

1

28

1

14

120

50 ++

0,050,02

128 137,50

12

0

276,50

115

1

80

,50

4

0

47

20,20

6

0

9

30

10

5

2,5

0

3

0

1

0

40,50

1

32

59

Page 60: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1820 potentiometric output – Measurement range 0 up to 20 000 mm

Specifications:

Measurement range 0 up to 20 000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 3 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 2 m/s2 (before cable deformation)

Weight ≈ 12 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1820

Measurement range

20000 = 0 up to 20 000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 3 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1820-20000-R01K-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

20 000 ≈ 15,00 N ≈ 30,00 N

CDS1820 OP

60

Page 61: AK-Industries - English catalog

2

18

,50

1

79

317,50

110

12

0

154,50

1

80

2

0

1

70

1

00

26

1

6,5

0

1

1,5

0

20

180

3

8

10

48,50

6

0

8

0

17,50

1

74

,50

2

0

9

1

0

30

(connector M12 - 4 pin)K connection

(PVC cable - 4 wires)

)L4 connection

C connection(Connector M16 - DIN 3 pin

Modular base plate

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

180

1

90

200 1

0

1

26

61

Page 62: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD1820 analog output – Measurement range 0 up to 20 000 mm

Specifications:

Measurement range 0 up to 20 000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 8 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 2 m/s2 (before cable deformation)

Weight ≈ 12 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1820

Measurement range

20000 = 0 up to 20 000 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 8 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1820-20000-U010-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

20 000 ≈ 15,00 N ≈ 30,00 N

CDS1820 OP

62

Page 63: AK-Industries - English catalog

1

79

2

18

,50

K connection(PVC cable - 4 wires)

L4 connection(connector M12 - 4 pin)

Modular base plate

C connection(Connector M16 - DIN 3 pin )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

200

180

1

90

1

0

1

26

2

0

1

70

26

1

00

12

0

317,50

110 154,50

1

80

8

0

20

180

30

1

0

3

8

48,50

17,50

6

0

10

1

74

,50

2

0

9

1

1,5

0

1

6,5

0

63

Page 64: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1820-MEC mechanical devices - Measurement range 0 up to 20 000 mm

Specifications:

Measurement range 0 up to 20 000 mm

Circumference drum 500 mm/turn

Sensing device Adaptable with all of our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 2 m/s2 (before cable deformation)

Weight ≈ 12kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1820-MEC

Measurement range

20 000 = 0 up to 20 000 mm

(Other ranges available on demand)

Drum circumference

500 = 500 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CDS1820-MEC-20000-500-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

20 000 ≈ 15,00 N ≈ 30,00 N

CDS1820 MEC OP

64

Page 65: AK-Industries - English catalog

1

79

11

2

18

,50

Modular base plate

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

Oldham coupling adaptable to the detection element that

will be mounted (see options)

1

00

1

90

1

0

200

180

50 ++

0,050,02

1

70

1

00

154,50

18

0

110

282,50

1

0

20

180

3

8

10

48,50

6

0

8

0

17,50

1

74

,50

2

0

9

30

65

Page 66: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1830 potentiometric output – Measurement range 0 up to 30 000 mm

Specifications:

Measurement range 0 up to 30 000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 3 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 2 m/s2 (before cable deformation)

Weight ≈ 15 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1830

Measurement range

30000 = 0 up to 30 000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 3 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1830-30000-R01K-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

30 000 ≈ 15,00 N ≈ 30,00 N

CDS1830 OP

66

Page 67: AK-Industries - English catalog

1

79

11

2

18

,50

20

180

1

83

5

0

9

0

2

0

9

10

3

5

1

1,5

0

48,50

2

1,5

0

28,50

30

Modular base plate

L4 connection(connector M12 - 4 pin)

K connection(PVC cable - 4 wires)

148

354

160

1

15

1

80

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

C connection(Connector M16 - DIN 3 pin )

1

90

200

180

1

0

1

26

2

0

1

6,5

0

1

00

26

1

70

67

Page 68: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD1830 analog output – Measurement range 0 up to 30 000 mm

Specifications:

Measurement range 0 up to 30 000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 8 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 2 m/s2 (before cable deformation)

Weight ≈ 15 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1830

Measurement range

30000 = 0 up to 30 000 mm

(Other ranges available on-demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 8 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1830-30000-U010-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

30 000 ≈ 15,00 N ≈ 30,00 N

CDS1830 OP

68

Page 69: AK-Industries - English catalog

11

2

18

,50

1

79

1

15

354

160 148

1

80

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

K connection(PVC cable - 4 wires)

)L4 connection(connector M12 - 4 pin)

C connection(Connector M16 - DIN 3 pin

Modular base plate

1

00

26

1

70

1

6,5

0

20

20

180

1

83

5

0

9

0

2

0

9

10

3

5

48,50

1

1,5

0

28,50

2

1,5

0

30

1

90

200

180

1

0

1

26

69

Page 70: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1830-MEC mechanical devices - Measurement range 0 up to 30 000 mm

Specifications:

Measurement range 0 up to 30 000 mm

Circumference drum 500 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 2 m/s2 (before cable deformation)

Weight ≈ 15kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1830-MEC

Measurement range

30 000 = 0 up to 30 000 mm

(Other ranges available on demand)

Drum circumference

500 = 500 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CDS1830-MEC-30000-500-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

30 000 ≈ 15,00 N ≈ 30,00 N

CDS1830 MEC OP

70

Page 71: AK-Industries - English catalog

2

18

,50

11

1

79

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

1

00

1

70

Oldham coupling adaptable to the detection element that

will be mounted (see options)

1

90

200

180

1

0

50 ++

0,050,02

1

00

Modular base plate1

80

148 160

319

20

28,50

180

1

83

2

1,5

0

5

0

9

0

2

0

9

3

5

48,50

10

30

71

Page 72: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1840 potentiometric output – Measurement range 0 up to 40 000 mm

Specifications:

Measurement range 0 up to 40 000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 3 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 1 m/s2 (before cable deformation)

Weight ≈ 20 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1840

Measurement range

40000 = 0 up to 40 000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 3 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1840-40000-R01K-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

40 000 ≈ 15,00 N ≈ 30,00 N

CDS1840 OP

72

Page 73: AK-Industries - English catalog

1

79

11

2

18

,50

)L4 connection

(PVC cable - 4 wires)K connection

(connector M12 - 4 pin)

C connection(Connector M16 - DIN 3 pin

Modular base plate

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

180

427

1

15

18

0

180

200

1

90

180

1

0

1

26

10 180

48,37

20

30

2

35

5

5

9

0

5

0

2

0

9

28,50

2

1,5

0

1

1,5

0 2

0

1

6,5

0

1

00

1

70

26

73

Page 74: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD1840 analog output – Measurement range 0 up to 40 000 mm

Specifications:

Measurement range 0 up to 40 000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 1 m/s2 (before cable deformation)

Weight ≈ 20 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1840

Measurement range

40000 = 0 up to 40 000 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1840-40000-U010-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

40 000 ≈ 15,00 N ≈ 30,00 N

CDS1840 OP

74

Page 75: AK-Industries - English catalog

1

79

11

2

18

,50

K connection(PVC cable - 4 wires)

427

180

18

0

1

15

180

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

Modular base plate

C connection(Connector M16 - DIN 8 pin )

200

1

90

180

1

0

1

26

2

1,5

0

10 180

48,50

20

30

2

35

5

5

9

0

5

0

2

0

9

28,50

1

1,5

0 2

0

L4 connection(connector M12 - 4 pin)

1

6,5

0

1

00

26

1

70

75

Page 76: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1840-MEC mechanical devices - Measurement range 0 up to 40 000 mm

Specifications:

Measurement range 0 up to 40 000 mm

Circumference drum 500 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 1 m/s2 (before cable deformation)

Weight ≈ 20kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1840-MEC

Measurement range

40 000 = 0 up to 40 000 mm

(Other ranges available on demand)

Drum circumference

500 = 500 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CDS1840-MEC-40000-500-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

40 000 ≈ 15,00 N ≈ 30,00 N

CDS1840 MEC OP

76

Page 77: AK-Industries - English catalog

1

79

11

2

18

,50

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

Oldham coupling adaptable to the detection element that

will be mounted (see options)

200 1

0

1

00

1

90

180

50 ++

0,050,02

10 180

20

30

2

35

5

5

9

0

2

0

5

0

9

2

1,5

0

28,50

48,50

1

70

1

00

Modular base plate

180 180

18

0

392

77

Page 78: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1850 potentiometric output – Measurement range 0 up to 50 000 mm

Specifications:

Measurement range 0 up to 50 000 mm

Output signal 1kΩ potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 - DIN 3 pin

Male connector M12 - 4 pin

PVC cable - 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 1 m/s2 (before cable deformation)

Weight ≈ 23 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1850

Measurement range

50000 = 0 up to 50 000 mm

(Other ranges available on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 - DIN 3 pin

L4 = Male connector M12 - 4 pin

K = PVC cable - 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1850-50000-R01K-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

50 000 ≈ 15,00 N ≈ 30,00 N

CDS1850 OP

78

Page 79: AK-Industries - English catalog

1

79

11

2

18

,50

K connection(PVC cable - 4 wires)

L4 connection(connector M12 - 4 pin)

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

200

467

18

0

12

0

180 180

1

90

200 1

0

1

26

C connection(Connector M16 - DIN 3 pin )

30

180

9

0

5

0

2

55

7

5

2

0

9

10

1

1,5

0

2

1,5

0

48,50

28,50

20

2

0

1

6,5

0

Modular base plate

1

00

26

1

70

79

Page 80: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CD1850 analog output – Measurement range 0 up to 50 000 mm

Specifications:

Measurement range 0 up to 50 000 mm

Output signal 0…10V (galvanic isolation)

4…20mA current loop

4…20mA current generator (galvanic isolation)

0…20mA current generator (galvanic isolation)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Standard linearity +/- 0,15% f.s.

+/- 0,10% f.s. (optional)

Protection class IP65

Max. Velocity 10 m/s

Max. Acceleration 1 m/s2 (before cable deformation)

Weight ≈ 23 kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1850

Measurement range

50000 = 0 up to 50 000 mm

(Other ranges available on demand)

Output signal

U010 = 0…10V

I420 = 4…20mA (current loop)

I420G = 4…20mA (current generator)

I020G = 0…20mA (current generator)

Linearity

L15 = +/- 0.15% f.s.

L10 = +/- 0.10% f.s. (optional)

Connection

C = Male connector M16 – DIN 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

IP67 = Protection class IP67

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

Reference example: CDS1850-50000-U010-L15-K02-OP-AC-M6

Measurement

range in mm Min. pull-out force Max. pull-out force

50 000 ≈ 15,00 N ≈ 30,00 N

CDS1850 OP

80

Page 81: AK-Industries - English catalog

1

79

11

2

18

,50

Modular base plate

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

12

0

467

200

1

80

180

1

90

200

180

1

0

1

26

C connection(Connector M16 - DIN 8 pin )

30

180

2

1,5

0

28,50

9

0

5

0

2

55

7

5

1

1,5

0

2

0

9

10

20

48,50

K connection(PVC cable - 4 wires)

2

0

L4 connection(connector M12 - 4 pin)

1

6,5

0

1

00

26

1

70

81

Page 82: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

CDS1850-MEC mechanical devices - Measurement range 0 up to 50 000 mm

Specifications:

Measurement range 0 up to 50 000 mm

Circumference drum 500 mm/turn

Sensing device Adaptable with all our incremental or absolute encoders

Material Body and cover - aluminium (RohS)

Measuring cable - Stainless steel

Cable diameter 0,90 mm

Standard linearity +/- 0,05% f.s.

+/- 0,01% f.s. (optional)

Max. Velocity 10 m/s

Max. Acceleration 1 m/s2 (before cable deformation)

Weight ≈ 23kg

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Cable forces:

Ordering reference:

Model

CDS1850-MEC

Measurement range

50 000 = 0 up to 50 000 mm

(Other ranges available on demand)

Drum circumference

500 = 500 mm/turn

Linearity

L05 = +/- 0.05% f.s.

L01 = +/- 0.01% f.s. (optional)

OP options

06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)

10 = Adapter flange for Ø58 encoder with Ø10 axis

12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing

BR = Cleaning brush for the cable

BT = Low temperature (down to -30°C)

CP = Fixing of the measuring cable with a clevis

M6 = Fixing of the measuring cable with a M6 threaded rod

TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)

If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.

For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.

Reference example: CDS1850-MEC-50000-500-L05-OP-10-AC

Measurement

range in mm Min. pull-out force

Max. pull-out

force

50 000 ≈ 15,00 N ≈ 30,00 N

CDS1850 MEC OP

82

Page 83: AK-Industries - English catalog

11

2

18

,50

1

79

Modular base plate

1

00

1

70

2

1,5

0

30

180

9

0

5

0

48,50

2

55

7

5

2

0

9

10

20

28,50

Oldham coupling adaptable to the detection element that

will be mounted (see options)

180

1

0

1

00

1

90

200

50 ++

0,050,02

200

18

0

180

432

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 83

Page 84: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

AS40 potentiometric output – Measurement range from 90 to 3600°

Specifications:

Measurement range 90 to 3600°

Output signal 1kΩ Potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel 303

Axis diameter 10mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Linearity +/- 0,25% fs (other values on demand)

Shock resistance ≤ 300m.s-2

(11 ms)

Vibration resistance ≤ 100m.s-2

(10 … 500 Hz)

Protection class IP65 (other on demand)

Weight ≈ 200 g

Operating temperature -10° to +70°C

Storage temperature -20° to +100°C

Ordering reference:

Model

AS40

Measurement range

0090 = 90°

0180 = 180°

0340 = 340°

1800 = 1800°

3600 = 3600°

(other values on demand)

Output signal

R01K = 1kΩ output

(Other values on demand)

Output sense

H = CW

A = CCW

Linearity

L50 = +/- 0.50% FS (standard for ranges up to 340°)

L25 = +/- 0.25% FS (standard for ranges superior than 340°)

(optional for ranges up to 340°)

L15 = +/- 0.15% FS (optional for ranges superior than 340°)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

IP67 = Protection class IP67

Reference example: AS40-3600-R01K-H-L25-K02-OP-IP67

AS40 OP

84

Page 85: AK-Industries - English catalog

28

40

3 x M3 5 at 120°

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

L4 connection(connector M12 - 4 pin)

K connection(PVC cable - 4 wires)

C connection(Connector M16 - DIN 3 pin )

48

3

57,50

3

2

0 f

7

1,50

17

6 g

7

36

f7

3

2

2

12,50

17,50

20

85

Page 86: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

AS40 Analog output – Measurement range from 90 to 3600°

Specifications:

Measurement range 90 to 3600°

Output signal - 0…10V

- 4…20mA Current loop

- 4…20mA Current generator - 0…20mA Current generator

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel 303

Axis diameter 10mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – 8 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Linearity +/- 0,25% fs (other values on demand)

Shock resistance ≤ 300m.s-2

(11 ms)

Vibration resistance ≤ 100m.s-2

(10 … 500 Hz)

Protection class IP65 (other on demand)

Weight ≈ 200 g

Operating temperature -10° to +70°C

Storage temperature -20° to +100°C

Ordering reference:

Model

AS40

Measurement range

0090 = 90°

0180 = 180°

0340 = 340°

1800 = 1800°

3600 = 3600°

(other values on demand)

Output signal

U010 = Output 0…10V

I420 = Output 4…20mA (2-wires current loop)

I420G = Output 4…20mA (current generator)

I020G = Output 0…20mA (current

Output sense

H = CW

A = CCW

Linearity

L50 = +/- 0.50% FS (standard for ranges up to 340°)

L25 = +/- 0.25% FS (standard for ranges superior than 340°)

(optional for ranges up to 340°)

L15 = +/- 0.15% FS (optional for ranges superior than 340°)

Connection

C = Male connector M16 – 8 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

IP67 = Protection class IP67

Reference example: AS40-3600-i420-H-L25-K02-OP-IP67

AS40 OP

86

Page 87: AK-Industries - English catalog

28

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

)

(connector M12 - 4 pin)L4 connection

C connection(Connector M16 - DIN 8 pin

K connection(PVC cable - 4 wires)

20

17,50

3

60

3

1,50

2

0 f

7

17

6 g

7

36

f7

3

2

12,50

2

69,50

40

3 x M3 5 at 120°

87

Page 88: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0

Made in France

AS58 potentiometric output – Measurement range from 90 to 3600°

Specifications:

Measurement range 90 to 3600°

Output signal 1kΩ Potentiometer (other values on demand)

Resolution Quasi infinite (depends on the operating system)

Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel 303

Axis diameter 10mm

Detection element Multi-turn Hybrid potentiometer

Connection Male connector M16 – DIN 3 pin

Male connector M12 – 4 pin

PVC cable – 4 wires

Linearity +/- 0,50% fs – Range from 340° and 1080°

+/- 0,25% fs – Range from 1800° and 3600°

Range from 340° and 1080° (optional)

+/- 0,15% fs – Range from 1800° and 3600° (optional)

Shock resistance ≤ 500m.s-2

(6 ms)

Vibration resistance ≤ 100m.s-2

(55 … 2 000 Hz)

Protection class IP54 (option IP67)

Weight ≈ 300 g

Operating temperature -20° to +80°C

Storage temperature -30° to +80°C

Ordering reference:

Model

CD50

Measurement range

0340 = 0 to 340°

1080 = 0 to 1080°

1800 = 0 to 1800°

3600 = 0 to 3600°

Output signal

R01K = 1kΩ output

(Other values on demand)

Linearity

L50 = +/- 0.50% fs (standard for range from 340° and 1080°)

L25 = +/- 0.25% fs (standard for range from 1800° and 3600°)

(optional for range from 340° and 1080°)

L15 = +/- 0.15% fs (optional for range from 1800° and 3600°)

Connection

C = Male connector M16 – DIN 3 pin

L4 = Male connector M12 – 4 pin

K = PVC cable – 4 wires + ex: 02 for cable 2 meters long

OP Options

AC = Complete anodizing

BT = Low temperature (down to -30°C)

IP67 = Protection class IP67

Reference example: AS58-3600-R01K-H-L25-K02-OP-IP67

CD50 OP

88

Page 89: AK-Industries - English catalog

48

19 10

3

1,7

5

10

g7

78 11,50

2

3

6

16,50

20

(connector M12 - 4 pin)L4 connection

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 3 pin ) 58

3 x M4 6 at 120°

3 x M3 6 at 120°

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 89

Page 90: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

AS58 Analog output – Measurement range from 90 to 3600° Specifications: Measurement range 90 to 3600° Output signal 0…10V (galvanic isolation) 4…20mA ; 2 wires technique 4…20mA ; 4 wires technique (galvanic isolation) 0…20mA ; 4 wires technique (galvanic isolation) Resolution Quasi infinite (depends on the operating system) Material Body and cover - Aluminium (RohS)

Measuring cable – Stainless steel 303 Axis diameter 10mm Detection element Multi-turn Hybrid potentiometer Connection Male connector M16 –8 pin

Male connector M12 – 4 pin PVC cable – 4 wires Linearity +/- 0,50% fs – Range ≤ 340° +/- 0,25% fs – Range > 340° Range ≤ 340° (optional) +/- 0,15% fs – Range > 340° (optional)

Shock resistance 500m.s-2 (6 ms)

Vibration resistance 100m.s-2 (55 … 2 000 Hz) Protection class IP54 (option IP67) Weight ≈ 700 g Operating temperature -20° to +80°C Storage temperature -30° to +80°C Ordering reference:

Model

AS58 Measurement range

0340 = 0 to 340° 1080 = 0 to 1080° 1800 = 0 to 1800° 3600 = 0 to 3600° (Other values on demand) Output signal

U010 = 0…10V I420 = 4…20mA (2 wires technique) I420G = 4…20mA (4 wires technique) I020G = 0…20mA (4 wires technique) Linearity

L50 = +/- 0.50% fs (standard for ranges from 340° to 1080°) L25 = +/- 0.25% fs (standard for ranges from 1800° to 3600°)

(optional for ranges from 340° to 1080°) L15 = +/- 0.15% fs (optional for ranges from 1800° to 3600°) Connection

C = Male connector M16 – DIN 8 L4 = Male connector M12 – 4 pin K = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options

AC = Complete anodizing BT = Low temperature (down to -30°C) IP67 = Protection class IP67 Reference example: AS58-3600-U010-H-L25-K02-OP-IP67

AS58 OP

90

Page 91: AK-Industries - English catalog

48

58

6 at 120° 3 x M4

3 x M3 6 at 120°

16,50

20

(connector M12 - 4 pin)L4 connection

(PVC cable - 4 wires)K connection

C connection(Connector M16 - DIN 8 pin )

Dimensional Drawing

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France

19 10

10

g7

3

1,7

5

78 11,50

2

3

6

91

Page 92: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France

Electrical characteristics for draw-wire sensors with potentiometric output

Potentiometric version 1 K : (other values on demand) Temperature drift +/-50 ppm/°C

Example of wiring diagram with input stage :

To ensure a good linearity, wire the potentiometer as a voltage divider and never as a rheostat. The input resistance of the operating system must be very high (greater than 10MΩ) Connection :

Male connector M16 3 pin (DIN)

Male connector M12 4 pin (DIN)

PVC cable 4 wire

R01K

1 1 Brown Input voltage +

2 2 White Input voltage GND

3 3 Green Signal +

Sensor side view

Sensor side view

92

Page 93: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France

Electrical characteristics for draw-wire sensors with analog output Analog version 0 … 10V : Input voltage 15 to +27 Vdc (52mA max) Output voltage 0 to 10 Vdc Output current 10mA max Galvanic isolation 3KV Protection - Short circuit - Polarity reversal Temperature drift +/-100 ppm/°C Analog version 4 … 20mA : (Two-wires current loop) Input voltage +15 to +27 Vdc (32mA max) Output current 4 to 20mA Protection - Short circuit - Polarity reversal Temperature drift +/-100 ppm/°C Analog version 4…20mA or 0…20mA : (Current generator) Input voltage +15 to +27 Vdc (75mA max) Output current 4 to 20mA or 0 to 20mA Output current 22 mA max. Galvanic isolation 3KV Protection - Short circuit - Polarity reversal Temperature drift +/-100 ppm/°C Connection :

Male connector M16 8 pin (DIN)

Male connector M12 4 pin (DIN)

PVC cable 4 wire

010V I420

(current loop) I420G or I020G

(current generator)

1 1 Brown Input voltage + Signal + Input voltage +

2 2 White Input voltage GND Signal - Input voltage GND

3 3 Green Signal + Signal +

4 4 Yellow Signal GND Signal GND

Sensor side view

Sensor side view

93

Page 94: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France

Electrical characteristics for draw-wire sensors with incremental output Electronic 2G2 (100kHz) (for CD50)

Supply : 5Vdc 10% Cons. without load : 100mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 2,5Vdc

Electronic 5G5 (100kHz) Supply: 11 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc

Electronic 9G5 (100kHz) Supply: 5 à 24Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc

Electronic PG5 (100kHz) (for CD50) Supply: 5 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc

Electronic 2G2 (100°C, 300kHz) Supply : 5Vdc 10% Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc

Electronic PG5 (100°C, 300kHz) Supply : 5 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc

Electronic RG2 (100°C, 300kHz) Supply : 4,75 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc

Electronic 5GT (70°C, 120kHz) Supply : 11 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 1,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc

Connection:

Male connector M23

12 Pin - CW

Male connector M23

12 Pin - CCW

Male connector M16 8 pin (DIN)

Male connector M16 5 pin (DIN)

PVC cable 8 wire

PUR cable 12 wire

Standard connection

1 10 + 11 1 1 White White +

White/Green Supply -

2 2 + 12 2 2 Brown Brown +

Brown/Green Supply +

3 8 3 3 Green Grey A

4 5 4 4 Yellow Brown B

5 3 5 5 Grey Red 0

6 1 6 / Pink Pink A/

7 6 7 / Blue Green B/

8 4 8 / Red Black 0/

Sensor side view

Sensor side view

Sensor side view

Sensor side view

PUR 12-Leiter-

Kabel

94

Page 95: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France

Options for draw-wire sensors, CD Series Cable attachment with a lug : Standard The attachment lug is fixed with a M6 screw or a clevis. Available for : CD50, CD60, CD80, CD115, CD150

Cable attachment with a clip : OP-EM This fastening system allows a rotation about its axis. The clip is fixed with a M4 screw or a clevis. Available for : CD50, CD60, CD80

Cable attachment fitted with a M4 threaded rod: OP-M4 The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate

does not exceed 5 mm. Caution Never screw the threaded rod into a fixed nut, a twist of the measurement cable would damage it. Available for : CD50, CD60, CD80, CD115, CD150

Cable attachment with a clevis : OP-CP The attachment of the clevis is done using a pin (provided). Available for : CD50, CD60, CD80, CD115, CD150

Cable dust wiper OP-RAC The dust wiper cleans the cable in dusty or humid environments. Available for : CD50

Cable cleaning brush: OP-BR The cleaning brush wipes the cable in dusty or humid environments. Available for : CD60, CD80, CD115, CD150

Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CD50, CD60, CD80, CD115, CD150

95

Page 96: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France

Options for draw-wire sensors, CDS Series

Cable attachment with a lug : Standard Measuring cable attachment with a lug. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850

Cable attachment fitted with a M6 threaded rod: OP-M6 The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate does not exceed 8mm. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850

Cable cleaning brush: OP-BR The cleaning brush wipes the cable in dusty or humid environments. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850

Cable attachment with a clevis : OP-CP The attachment of the clevis is done using a pin (provided). The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850

Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850

Please specify the implantation angle of the drain holes on the drawing below.

(All value between 0 and 360°)

96

Page 97: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France

Adapter flanges Adaptation for an encoder of diameter 58mm, and shaft diameter 6mm OP-06: Adaptation flange + Ø6 Oldham coupling OP-06A: Ø6 Oldham coupling without adaptation flange Adaptation for an encoder of diameter 58mm, and shaft diameter 10mm OP-10: Adaptation flange + Ø10 Oldham coupling Without specification, a MEC series draw-wire sensor will always be delivered with an Oldham coupling Ø10 without adaptation flange.

Adaptation for an encoder of diameter 90mm, and shaft diameter 12mm OP-12: Adaptation flange + Ø12 Oldham coupling OP-12A: Ø12 Oldham coupling without adaptation flange

97

Page 98: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Connectors

Female connectors

M12 4-Pins Female connector

For M-connection

Ø of the cable: 4 to 6 mm

Ref : 5100-020

M16 Female connector - DIN

For C-connection (3-Pins)

Ø of the cable: 4 to 6 mm

Ref: 5100-007

M16 Female connector - DIN

For C-connection (8-Pins)

Ø of the cable: 4 to 6 mm

Ref: 5100-008

M23 CCW female connector

For G6-connection (mounting on CW baseplate)

Ø of the cable: 6 to 8 mm

Ref: 5100-006

M23 CW female connector

For G8-connection (mounting on CCW baseplate)

Ø of the cable: 6 to 8 mm

Ref: 5100-005

98

Page 99: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Mounting accessories

Magnet clamp FAIM-5 (for CD50)

Magnet clamp FAIM-25 (for CD115 and CD150)

Pulley PR01 (for CD50)

Pulley PR03

Cable extension

- M4 cable plugs on both ends. Ref. : RL-XXXX-M4/M4

- Attachment heads on both ends. Ref. : RL-XXXX-CP/CP

- Cable lugs on both ends. Ref. : RL-XXXX-CO/CO

Other possibilities: RL-XXXX-M4/CO (M4 screw at one end – lug on the other) RL-XXXX-M4/CP (M4 screw at one end – attachment head on the other) RL-XXXX-CO/CP (Lug at one end – attachment head on the other Possibility to integrate directly the cable extension into the sensor

Heating module for draw-wire sensors, series CDS

The heating module prevents the sensor to freeze under negative

operating temperature.

Don’t hesitate to contact us for any further information

99

Page 100: AK-Industries - English catalog

We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France

Accessories

Clearance compensation angle Fixation angle

Ref : ERJ40-002 Ref : EF058-001

Measuring wheel Oldham coupling

Ref : RM200-001

Cylindrical eccentric (to mount angular sensors and optical encoders)

Provided with a set of 4 eccentrics + 4 screws

Ref : EXC-001 Ref : EXC-002

100