air-gas analysis
DESCRIPTION
AIR SAMPLING - ACCESSORIES 3500 Air Sample Pump Kit Air Quality Meters AirAware Fixed-Gas Monitors Allegro T100M Air Sampling Pump Apex Sampling Pumps Automatic Gas Sampling Pump CMS Analyzer and Chips Carbon Dioxide MetersTRANSCRIPT
4
Air/Gas AnalysisAIAir Sampling / Accessories
C10370-01
Gas Sampling AccessoriesA Scienceware® Gas Washing Bottle consists of a 250-mL polypropylene graduated cylinder with extended base, a 38-mm vinyl stopper with 1⁄4" OD tubes, and a removable gas dispersion fitting with 70-µm porosity polyethylene disc. Maximum pressure is 0.5 psi.B Gas Dispersion Tube linear polyethylene bell-mouthed fitting has a sealed 70-µm porosity disc.C Glass Gas Sampling Bulbs are designed for the collection and storage of environmental samples. Top cap with a PTFE/silicone septum lets you withdraw analytical samples. Both ends have a 4-mm valve plug and are ground to accept 3⁄8" ferrules and hand compressible fittings for a gas-tight seal. GPI thread size: 13-425.
A06652-00
B06614-25
Economical choice for noncorrosive gases such as CO, SO2, H2S, radon, and mercaptans lStrong seams for added durabilitylResists temperatures up to 400°F All standard and light-blocking models have either an on/off valve (3⁄16" nickel-plated brass hose barb) or a silicone septum in polypropylene housing; dual-valve models have both. Max temp: 225°F (107°C) continuous use, 400°F (204°C) intermittent use. Individually sealed in a dust-protected outer bag.
Light-Blocking Tedlar PVF BagsDouble-wide seamed bags are ideal for light-sensitive applications.
Dual-Valve Tedlar PVF BagsSingle-wide seamed bags have both on/off and septum valves for convenient mixing.
Tedlar® PVF Gas Sampling Bags
Standard Tedlar PVF BagsSingle-wide seam; available in 2-mil and 4-mil thick styles.
FEP Sampling BagsReusable bags resist damage from radiation and corrosive gasesl Extra rugged—5 mil thickl Resists temperatures up to 200°F Available in two styles—bags with on/off valve (3⁄16" nickel-plated brass hose barb) or with a silicone septum in a polypropylene housing. Max temp: 200°F (93°C). Thickness: 5 mil. Individually sealed in a dust-protected outer bag.
Tedlar PVF bag with septum valve
Light-blocking Tedlar PVF bag with on/off
valve
Simply twist on/off valves to control gas introduction
or release.
Septum valves permit more precise work—use a syringe
to introduce and remove known sample volumes.
FEP bag with septum valve
On/off valve Septum valveVolume Dimensions
Cat. no. Price Cat. no. PriceStandard 2-mil bags
RZ-01409-10 RZ-01409-20 0.3 L 6"L x 6"WRZ-01409-11 RZ-01409-21 1.6 L 9"L x 9"WRZ-01409-12 RZ-01409-22 3.8 L 12"L x 12"WRZ-01409-13 RZ-01409-23 8.1 L 15"L x 15"WRZ-01409-14 RZ-01409-24 20.3 L 18"L x 18"WRZ-01409-15 RZ-01409-25 37.7 L 24"L x 24"WRZ-01409-16 RZ-01409-26 85.7 L 30"L x 30"W
Standard 4-mil bagsRZ-01409-31 — — 1.6 L 9"L x 9"WRZ-01409-32 — — 3.8 L 12"L x 12"WRZ-01409-33 — — 8.1 L 15"L x 15"W
On/off valve Volume Dimensions
Cat. no. PriceRZ-01409-51 1.6 L 9"L x 9"WRZ-01409-52 3.8 L 12"L x 12"WRZ-01409-53 8.1 L 15"L x 15"W
Catalog number Volume Dimensions PriceRZ-01409-90 0.3 L 6"L x 6"W RZ-01409-91 1.6 L 9"L x 9"W RZ-01409-92 3.8 L 12"L x 12"W RZ-01409-93 8.1 L 15"L x 15"W RZ-01409-94 20.3 L 18"L x 18"W RZ-01409-95 37.7 L 24"L x 24"W RZ-01409-96 85.7 L 30"L x 30"W
On/off valve Septum valveVolume Dimensions
Cat. no. Price Cat. no. PriceRZ-01430-10 RZ-01430-50 0.5 L 6"L x 6"WRZ-01430-20 RZ-01430-60 1.2 L 6"L x 10"WRZ-01430-30 RZ-01430-70 4.7 L 12"L x 12"WRZ-01430-40 RZ-01430-80 50.0 L 24"L x 36"W
Tedlar PVF dual-valve bag with on/off and
septum valves
Key Catalog number Description Volume Dimensions Qty PriceA RZ-06652-00 Gas washing bottle 250 mL Accepts tubes up to 1⁄4" OD 1 ea B RZ-06614-25 Gas dispersion tube — 12"L x 1" OD at bell, 3⁄58" OD tube 4/bg
CRZ-10370-00
Glass gas sampling bulb125 mL 111⁄2"L x 31⁄2"W
1 ea
RZ-10370-01 250 mL 113⁄4"L x 33⁄4"W scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
2
Air/Gas AnalysisAIAir Sampling
Specifications
Apex Sampling PumpsLarge LCD of flow rate, volume sampled, elapsed sample time, and temperaturel Digital circuitry for precise and constant control of flow ratel Long-term stability between calibrationsVersatile pumps offer a broad measurement range to cover a variety of sampling applications. Three-button controls create user-friendly interface for operation. LCD can also be customized for your preferred data view. Apex pumps are designed to deliver real-time readings. Apex Pro pumps add data storage (100 events) and download via infrared RS-232 interface and software (sold separately). Both models are available with AA alkaline or rechargeable NiMH batteries.
What’s included: four AA alkaline batteries (models 86543-00, -10) or NiMH battery and 115 VAC charger (models 86543-02, -12).
RZ-86543-50 Low-flow controller/CPU for sample volumes 5 to 750 mL/min ................................................. RZ-86543-51 Infrared interface cable and software for use with Apex Pro models 86543-02, -12 .................
Data displayed: flow rate, volume sampled, elapsed sample time, temperature, operating mode, program details
Operating temperature: 41 to 104°F (5 to 40°C)
Battery life AA alkaline: varies by user settings NiMH: 34 hours
Tubing ID: 1⁄4" (6.4 mm)Dimensions:
31⁄2"W x 53⁄4"H x 13⁄4"D86543-00
Catalog number Description Flow range Low flow range,
constant flow† Pump wt Power Price
RZ-86543-00 Apex pump 0.8 to 5 L/min 5 to 750 mL/min 17.8 oz(0.5 kg)
Four AA alkaline batteries RZ-86543-02 NiMH with 115 VAC charger RZ-86543-10 Apex Pro pump 0.8 to 5 L/min 5 to 750 mL/min 17.8 oz
(0.5 kg)Four AA alkaline batteries
RZ-86543-12 NiMH with 115 VAC charger †Requires purchase of Low-flow controller 86543-50 (sold separately below).
SpecificationsData displayed: sample time, alarm Operating temperature: 32 to 105°F (0 to 40°C)
Tubing ID: 1⁄4" (6.4 mm)Dimensions: 6"W x 4"H x 5-1⁄2"D
Allegro T100M Air Sampling PumpExpanded flow range capabilitiesl Sample volumes from 3 to 30 L/minl Suitable for use with impactors Rotary vane sampling pump features broader 3 to 30 L/min sampling range. Built-in, adjustable flowmeter (5 to 50 L/min) allows easy display and adjustment to flow rate. This pump is specifically designed for use with cassettes and is also an excellent choice for work with impactors for impaction sampling. Order optional impactor or optional adjustable stand (sold separately below) for easy sample collection.
What’s included: flowmeter, in-line filters, muffler jar, and 6 feet of vinyl tubing.
86444-10 shown with stand 86444-51 and 86444-50 sampler
RZ-86444-50 Impactor sampler ...................................................................................................... RZ-86444-51 Optional adjustable stand ........................................................................................
Catalog number Description Flow range Pump wt Power PriceRZ-86444-10 T100M air sampling pump 3 to 30 L/min 10 lb (5.0 kg) 115 VAC
Instruments are not included.
Customize your case
with prescored “Pick-N-Pluck” foam
Unbreakable Instrument CasesProtect your valuable instrumentation—cases are absolutely air- and water-tight. They are constructed of high-impact polypropylene and feature ABS plastic latches. A 1⁄4"-thick neoprene O-ring guarantees a water- and dust-proof seal. Each case includes a “Pick-N-Pluck” foam liner—customize your case by simply removing pieces of foam. Models 40460-92 and -94 also include adjustable handle and rolling wheels for easy transport.
Catalognumber
Interiordimensions
Exteriordimensions Price
RZ-40460-80 81⁄2"L x 6"W x 33⁄4"H 91⁄4"L x 73⁄4"W x 41⁄2"H RZ-40460-82 91⁄2"L x 71⁄2"W x 41⁄2"H 103⁄4" x 93⁄4"W x 5"H RZ-40460-84 121⁄4"L x 91⁄4"W x 51⁄4"H 13"L x 12"W x 6"H RZ-40460-86 17"L x 113⁄4"W x 6"H 181⁄2"L x 151⁄4"W x 67⁄8"H RZ-40460-88 22"L x 17"W x 8"H 241⁄4"L x 191⁄2"W x 9"H RZ-40460-92 22"L x 17"W x 121⁄2"H 243⁄4"L x 191⁄2"W x 133⁄4"H RZ-40460-94 29"L x 73⁄4"W x 101⁄2"H 321⁄2"L x 201⁄2"W x 111⁄4"H
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
3
Air/Gas Analysis AIAir Sampling
Sampling Pump KitsReduce flow rates to as low as 0.001 L/min with the optional low flow modules
GilAir 3 is a compact yet full-featured sampler.
GilAir 5 is a double-diaphragm pump with a larger capacity battery to handle higher flow rates. Clock features run and hold functions.
What’s included: air boss (bag fill adapter), tubing, tool kit, rechargeable NiCd battery; 120 or 230 VAC charger; and filter cassette holder.
Approval UL: Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III CENELEC (86276-81 and 86276-87 only). CE.
Built-in rotameter on GilAir 3 and 5
Low-Flow Modules customize your pump for sampling volumes from 0.001 to 0.75 L/min.RZ-86276-84 Low-flow module, constant flow .................................................................................................................. RZ-86276-85 Low-flow module, multiflow .........................................................................................................................
230 VAC only
Data displayed: elapsed time, low battery, flow fault
Operating temperature: 32 to 113°F (0 to 40°C)
Battery life: 8 to 10 hrs at 3 L/min (full charge)
Tubing ID: 1⁄4" (6.4 mm)Dimensions:
311⁄16"W x 4"H x 2"D
86276-86
86276-80
Low-flow module 86276-84
l Gilian pumps with automated constant flow control ensure accuracy in high flow ranges
l EMI/FRI protection prevents interference from plant operations
l See-through inlet filter housing protects pumps from dirt and debris while allowing easy inspection
Gilibrator-2 calibration system provides a convenient and highly automated way to check almost any commercial air sampling pump. The system consists of an electronic base which is used with any one of three sizes of wet cells, and includes everything needed to calibrate sampling pump air flows from 0.001 to 30 L/min.
What’s included: three (low, standard, and high) interchangeable wet cells, control base with rechargeable NiCad battery pack, DC charger / AC power supply, tubing, hard-shell carrying case, and a thermal dot matrix printer.
Gilibrator-2® Diagnostic Calibration SystemCalibrate air flow from 0.001 to 30 L/min with ±1% wet cell accuracy
86276-96
Specifications
SpecificationsAccuracy:
±1% of rdg
230 VAC units only
Cell dimensions: 2"W x 4"H x 2"D (low); 21⁄2"W x 6"H x 211⁄16"D (standard); 31⁄2"W x 8"H x 33⁄4"D (high)
SpecificationsData displayed: flow rate, run time, total volume sampledOperating temperature: 32 to 113°F (0 to 45°C)Battery life: 8 to 11 hoursTubing ID: 1⁄4" (6.4 mm)Dimensions: 33⁄16"W x 415⁄16"H x 21⁄16"DWeight: 2 lb (1.0 kg)
3500 Air Sample Pump KitPump is accurate, reliable, and easy-to-uselHolds calibration for 30 days, even through temperature or flow rate changeslCalibrate in one location and run tests in another without fear of resulting error!
Pump also displays total run time so you know when to recalibrate. The NiMH battery eliminates “memory-related” data loss. A green indicator light flashes when the pump is operating within 5% of the set flow rate—you know at a glance it is working.
What’s included: air boss, 36"L tubing, tool kit, NiMH battery pack, AC charger, and filter cassette kit.
Approval UL: Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III Temp Code 3C. cUL: Class I, Div 1, Groups C, D; Class II, Groups F, G; Class III Temp Code 3C CENELEC (EEx ib llb T4). CE.
Catalognumber Flow range Low flow range,
constant flowLow flow range†,
multiflow Power Price
RZ-86276-7020 to 3500 mL/min 700 to 3500 mL/min 20 to 750 mL/min
at 18" ±3" H2O115 VAC
RZ-86276-71 230 VAC †Requires use of low-flow adapter 86276-73. Does not display live flow in this mode.
Display shows flow rate, run time,
and total volume sampled.
86276-70
RZ-86276-73 Low-flow adapter for multiflow sorbent sampling volumes from 20 to 750 mL/min ....................................................................................................................
Catalog number Description High flow range† Low flow range‡, constant flow Low flow range‡, multiflow Pump wt Power PriceRZ-86276-80 GilAir 3 0.75 to 3 L/min 0.001 to 0.50 L/min,
to 25" (640 mm) H2O
0.001 to 0.75 L/minat 18" ±3" (460 ±80 mm)
H2O (constant pressure)
21 oz (0.6 kg) 115 VAC RZ-86276-81 230 VAC RZ-86276-86 GilAir 5 0.75 to 5 L/min 22.5 oz (0.7 kg) 115 VAC RZ-86276-87 230 VAC
†Flow control is ±5% of set point. ‡ 0.001 to 0.75 L/min flow rates require low-flow module 86276-84 or 86276-85.
Catalog number Flow range Power PriceRZ-86276-96 0.001 to 0.25 L/min; 0.02 to 6 L/min; 2 to 30 L/min 115 VAC RZ-86276-97 230 VAC
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
6
Air/Gas AnalysisAIGas Detection, Detector Tubes / Pumps
Manual Gas Sampling PumpSpringless design for accurate 50- and 100-cc sample volumesl Flow finish indicator signals stroke completionl Built-in tube tip breaker for clean
break every timeHand-operated precision piston pump works with RAE System gas detection tubes (sold separately above). Features flow-finish indicator to signal stroke completion, stroke counter, and built-in tube-tip breaker.
What’s included: wrist strap.
Automatic Gas Sampling PumpProvides continuous or fixed-volume sampling from 50- to 950-cc in 50-cc increments
l Ensure error-free sample drawing with this intrinsically safe automatic gas sampling pump
l LCD indicates sampling status, selected flow rate, or sample volume
Pump accepts RAE System detection tubes (sold separately above).
What’s included: calibration tube, inlet adapter replacement, rechargeable NiCd battery pack with built-in charger, and adapter for four AA alkaline batteries (not included).
Approval: UL and cUL classified as intrinsically safe for Class 1, Division 1, Groups A, B, C, and D environments; EX 1211CT2 (Europe); CE
Gas Detection Tubes
Sharp, clear color change for unambiguous measurementsl Precalibrated, maintenance-free tubes accurately and
reproducibly indicate toxic gas concentrations. Two-year shelf life. Box of 10 tubes.
Catalog number Gas Range TLV (ppm) Price/boxRZ-86260-50 Acetone 0.1 to 2% 750 RZ-86260-51 Ammonia 5 to 100 ppm 25 RZ-86260-52 Ammonia 25 to 500 ppm 25 RZ-86260-53 Ammonia 1 to 15% 25 RZ-86260-54 Benzene 0.5 to 40 ppm 10 RZ-86260-55 Benzene 5 to 100 ppm 10 RZ-86260-56 Carbon dioxide 0.05 to 1% 5000 RZ-86260-57 Carbon dioxide 1 to 20% 5000 RZ-86260-70 Carbon dioxide 300 to 5000 ppm 5000 RZ-86260-58 Carbon monoxide 5 to 100 ppm 25 RZ-86260-59 Carbon monoxide 20 to 500 ppm 25 RZ-86260-60 Carbon monoxide 0.2 to 4% 25 RZ-86260-71 Chlorine 0.5 to 8 ppm 0.5 RZ-86260-61 Chlorine 5 to 100 ppm 0.5 RZ-86260-73 Hydrocarbons 50 to 1000 ppm — RZ-86260-74 Hydrogen chloride 1 to 20 ppm 5 RZ-86260-75 Hydrogen fluoride 0.5 to 20 ppm 3 RZ-86260-76 Hydrogen sulfide 0.2 to 2 ppm 10 RZ-86260-62 Hydrogen sulfide 2.5 to 60 ppm 10 RZ-86260-77 Hydrogen sulfide 10 to 120 ppm 10 RZ-86260-78 Hydrogen sulfide 25 to 250 ppm 10 RZ-86260-63 Hydrogen sulfide 50 to 800 ppm 10 RZ-86260-79 Hydrogen sulfide 100 to 2000 ppm 10 RZ-86260-64 Hydrogen sulfide 0.1 to 2% 10 RZ-86260-65 Hydrogen sulfide 2 to 40% 10 RZ-86260-80 MEK 0.02 to 6% 200 RZ-86260-66 Nitrogen oxides 1 to 50 ppm — RZ-86260-81 Phosphine 5 to 50 ppm 0.3 RZ-86260-82 Sulfur dioxide 2 to 30 ppm 2 RZ-86260-67 Sulfur dioxide 5 to 100 ppm 2 RZ-86260-68 Sulfur dioxide 200 to 4000 ppm 2 RZ-86260-83 Toluene 10 to 300 ppm 50 RZ-86260-84 Water vapor 2 to 10 lbs/MMCF — RZ-86260-85 Water vapor 6 to 40 lbs/MMCF — RZ-86260-69 Xylene 10 to 200 ppm 100
Catalog number Description Sample volume Price
RZ-86260-00 Manual gas sampling pump 50 and 100 cc
Catalog number Description Sample volume Price
RZ-86260-10 Automatic gas sampling pump 50 to 950 cc
RZ-09376-01 Replacement batteries, AA. Pack of 4 ................................................... /pk
GO to page(s) 2Safely store gas detection equipment for transport and use in the field. See our rugged, water-tight Pelican® cases on page 7.
Technical infoEasy-to-use colorimetric tubes:1. Break off the tube tips at both ends.2. Insert tube into pump (not included) and
draw sample.3. Read the concentration directly from
the printed scale.
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
5
Air/Gas Analysis AIGas Detection, Detector Pumps / Tubes
Pump Kit and Gas Detection Tubes Easy, one-handed operationlWider diameter tubes with well-spaced graduation
marks are easier to readlTwo-year shelf lifeThe accuro® gas detector pump is a manually operated bellows pump that draws a calibrated 100-mL sample through the short-term gas detection tubes (order tubes separately). Provides fast, accurate, reliable results in just seconds.
What’s included: pump, tube opener, spare parts kit, rubber caps (10/pk), and nylon case.
86514-00
Pump Kit
Gas Detection Tubes
Catalog number Description Sample
volume Price
RZ-86514-00 accuro® pump kit 100 mL
Catalog number Gas/vapor Range TLV Price/
box of 10RZ-86514-10 Acetic acid 5 to 80 ppm 10 ppm RZ-86514-12 Acetone 10 to 12,000 ppm 750 ppm
RZ-86514-61 Alcohol
25 to 5,000 ppm methanol 200 ppm
50 to 4,000 ppm propanol 400 ppm100 to 5,000 butanol 50 ppm
25 to 2,000 ethanol 1000 ppmRZ-86514-13 Ammonia 0.05 to 10% 25 ppm RZ-86514-14 Ammonia‡ 5 to 700 ppm 25 ppm RZ-86514-15 Ammonia 0.25 to 3 ppm 25 ppm RZ-86514-16 Arsine 0.05 to 3 ppm 0.05 ppm
RZ-86514-18† Benzene 0.5 to 10 ppm 0.5 ppm RZ-86514-20 Benzene 15 to 420 ppm 0.5 ppm RZ-86514-22 Carbon dioxide‡ 0.1 to 1.2% 5000 ppm RZ-86514-24 Carbon dioxide 1 to 20% 5000 ppm RZ-86514-26 Carbon monoxide 2 to 300 ppm 25 ppm RZ-86514-27 Carbon monoxide‡ 5 to 700 ppm 25 ppm RZ-86514-28 Carbon monoxide 0.1 to 7% 25 ppm RZ-86514-30 Chlorine 0.2 to 30 ppm 0.5 ppm RZ-86514-29 Chloroform 2 to 10 ppm 10 ppm RZ-86514-53 Ethyl acetate 200 to 3,000 ppm 400 ppm
RZ-86514-54† Ethylene 0.2 to 5 ppm asphyx RZ-86514-31† Ethylene glycol 10 to 180 mg/m3 100 mg/m3 RZ-86514-32† Ethylene oxide 1 to 15 ppm 1 ppm RZ-86514-34 Formaldehyde 2 to 40 ppm 0.3 ppm RZ-86514-55 Hexane 50 to 3,000 ppm 50 ppm RZ-86514-35 Hydrochloric acid 1 to 10 ppm 5 ppm RZ-86514-58 Hydrocyanic acid‡ 2 to 150 ppm 5 mg/m3 RZ-86514-59 Hydrogen fluoride 0.5 to 90 ppm 3 ppm RZ-86514-60 Hydrogen sulfide 0.2 to 5 ppm 10 ppm RZ-86514-37 Hydrogen sulfide 2 to 200 ppm 10 ppm RZ-86514-38 Hydrogen sulfide‡ 1 to 200 ppm 10 ppm RZ-86514-39 Hydrogen sulfide 100 to 2,000 ppm 10 ppm RZ-86514-40 Hydrogen sulfide 2 to 40% 10 ppm RZ-86514-62 Mercury 0.05 to 2 mg/m3 0.025 mg/m3
RZ-86514-64† Methyl bromide 3 to 100 ppm 5 ppm RZ-86514-42 Nitrogen dioxide‡ 0.5 to 25 ppm 3 ppm
RZ-86514-65 Nitrous gases 2 to 100 ppm 25 ppm NO 3 ppm NO3RZ-86514-44 Oxygen 5 to 23% — RZ-86514-46 Ozone 0.05 to 1.4 ppm 0.05 to 1 ppm
RZ-86514-56 Petroleum hydrocarbons 10 to 300 ppm —
RZ-86514-57 Petroleum hydrocarbons 100 to 2,500 ppm —
RZ-86514-66 Sulfur dioxide 1 to 25 ppm 2 ppm RZ-86514-50 Toluene 50 to 400 ppm 50 ppm RZ-86514-67 Trichloroethylene 2 to 250 50 ppm RZ-86514-68 Vinyl chloride 1 to 50 5 ppm RZ-86514-52 Xylene 10 to 400 ppm 100 ppm
†Models contain 10 twin tubes (5 tests/box). ‡SEI certified by Safety Equipment Institute
Diffusion TubesDirect-read tubes identify worker’s exposure to chemicalsDirect-reading diffusion tubes are used specifically for personal exposure monitoring. These tubes do not require the use of a gas detector pump because the contaminant molecules pass into the tube by diffusion processes and are brought into contact with the reagent systems. Exposure levels are easily read by the markings on the side of the tube. Use tube holder 86515-50 to clip diffusion tube onto shirt collar or pocket.
Catalog number Chemical Standard range Price/bx
of 101 hour 4 hoursRZ-86515-51 Acetic acid 10/a-D 10 to 200 ppm 1.3 to 25 ppm RZ-86515-52 Ammonia 20/a-D 20 to 1500ppm 2.5 to 200 ppm RZ-86515-53 Butadiene 10/a-D 10 to 300 ppm 1.3 to 40 ppm RZ-86515-54 Carbon dioxide 500/a-D 500 to 20,000 ppm 65 to 2500 ppm RZ-86515-55 Carbon dioxide 1%/a-D 1 to 30 % 0.13 to 4 % RZ-86515-56 Carbon monoxide 50/a-D 50 to 600 ppm 6 to 75 ppm RZ-86515-57 Ethanol 1000/a-D 1000 to 25,000 ppm 125 to 3100 ppm RZ-86515-58 Hydrochloric acid 10/a-D 10 to 200 ppm 1.3 to 25 ppm RZ-86515-59 Hydrocyanic acid 20/a-D 20 to 200 ppm 2.5 to 25 ppm RZ-86515-60 Hydrogen sulfide 10/a-D 10 to 300 ppm 1.3 to 40 ppm RZ-86515-61 Nitrogen dioxide 10/a-D 10 to 200 ppm 1.3 to 25 ppm RZ-86515-62 Perchloroethylene 200/a-D 200 to 1500 ppm 25 to 200 ppm RZ-86515-63 Sulfur dioxide 5/a-D 5 to 150 ppm 0.7 to 19 ppm RZ-86515-64 Toluene 100/a-D 100 to 3000 ppm 13 to 380 ppm RZ-86515-65 Trichloroethylene 200/a-D 200 to 1000 ppm 25 to 125 ppm
RZ-86515-50 Tube holder with clip. Pack of 3 ......................................... /pk
Tube 86515-55 shown with holder 86515-50
GO to page(s) 1469–1472
Protect workers from airborne contaminants. See our wide selection of respirators and masks.
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
7
Air/Gas Analysis AICMS Analyzer / Single-Gas Detectors
CMS Analyzer and Chips Eliminate user error for a consistent measurement every timelDigital display of gas
concentration eliminates ambiguous results
lInternal recorder stores up to 50 measurements with time/date stamp
Just load a CMS gas specific chip into the bottom port of the analyzer. Easy-to-use, three-step slide switch allows analyzer to take measurements. Gas concentration is displayed in seconds with digital readout. Operates on four AA batteries (included). Chips contain 10 tests each and are sold separately at right.
Approval: UL and CSA listed intrinsically safe for class 1, Div 1, Groups A-D, T4; CENELEC EEx ib IIC T4; MSHA
86513-00
CMS ChipsCatalog number Gas/vapor Range Price
RZ-86513-08 Acetic acid 2 to 50 ppm RZ-86513-09 Acetone 40 to 600 ppm RZ-86513-10 Ammonia 2 to 50 ppm RZ-86513-12 Ammonia 100 to 2000 ppm RZ-86513-14 Benzene 10 to 250 ppm RZ-86513-16 Carbon dioxide 200 to 3000 ppm RZ-86513-18 Carbon dioxide 1 to 20% RZ-86513-20 Carbon monoxide 15 to 150 ppm RZ-86513-22 Chlorine 0.2 to 10 ppm RZ-86513-23 Ethylene oxide 0.4 to 5 ppm RZ-86513-24 Formaldehyde 0.2 to 5 ppm RZ-86513-25 Hydrogen cyanide 2 to 50 ppm RZ-86513-26 Hydrogen sulfide 0.2 to 5 ppm RZ-86513-28 Hydrogen sulfide 2 to 50 ppm RZ-86513-30 Nitrogen dioxide 0.5 to 25 RZ-86513-32 Oxygen 1 to 30% RZ-86513-34 Ozone 25 to 1000 ppb RZ-86513-35 Petroleum hydrocarbons 20 to 500 ppm RZ-86513-36 Petroleum hydrocarbons 100 to 3000 ppm RZ-86513-37 Sulfur dioxide 5 to 150 RZ-86513-38 Toluene 10 to 300 ppm RZ-86513-39 Vinyl chloride 10 to 250 ppm RZ-86513-40 Xylene 10 to 300 ppm
RZ-09376-01 Replacement batteries, AA. Pack of 10 ................... /pk
Specifications for AnalyzerPower: four AA batteries (included)Dimensions: 31⁄2"W x 8"H x 13⁄4"D
Instrument wt: 25.6 oz (0.7 kg)
Catalog number Description PriceRZ-86513-00 CMS analyzer
MSHA
Pac 3000/5000 Single-Gas MonitorsBump test mode—requires user to expose monitor to gas periodically or prior to useThe monitor features a robust, rubber-coated weatherproof polymer housing that will stand up to the typical abuse in an industrial environment. Monitor is maintenance free and can be easily operated using two buttons. Its small size makes it comfortable and easy to wear all day on a belt, breast pocket, or lapel. A loud audible alarm, two bright visual alarms, and strong vibrating alarms alert you to hazardous concentrations of gas.
The Pac 3000 only shows gas formula until the measured value exceeds alarm set point. The Pac 5000 will continuously display gas concentrations, and is equipped with an event logger which will store up to 60 alarm activations or other events.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1, Groups A, B, C, D, E, F, G T4; ATEX; CE
Catalognumber Sensor Range Resolution
Alarm set pointsPrice
Low HighPac 3000 single-gas monitors
RZ-86515-04 O2 0 to 25% 0.1% 19.50% 23.50% RZ-86515-00 CO 0 to 500 ppm 1 ppm 35 ppm 50 ppm RZ-86515-02 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
Pac 5000 single-gas monitorsRZ-86515-14 O2 0 to 25% 0.1% 19.50% 23.50% RZ-86515-10 CO 0 to 500 ppm 1 ppm 35 ppm 50 ppm RZ-86515-12 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
SpecificationsAlarm: 90 dB at 12 inches (audible/visible/vibrating)Sensor life: 2 yearsFunctions: actual concentration, operating time
Display: LCDPower: lithium battery (included)Battery life: 2 years
86515-04
Dimensions: 21⁄2"W x 31⁄4"H x 3⁄4"DInstrument wt: 4 oz (0.1 kg)
RZ-06298-26 14 27-29 87 75 52 Pink 1 scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
8
Air/Gas AnalysisAISingle-Gas Detectors
ToxiRAE II Personal Gas MonitorsNo expiration date—turn on and off to preserve battery and sensor lifeMonitors provide continuous measurement and display of toxic gas concentration levels. Readings include STEL, TWA, peak, and high/low values. Varying audio alarm signals different alarm conditions to cue appropriate level of response. Durable, impact-resistant ABS housing is IP55-rated and performs well even with RFI interference. Single button monitor is easy to operate, with simple calibration procedure and adjustment of factory settings.
What’s included: belt clip/hard hat adapter, wrist strap, calibration adapter, and batteries.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1 Groups A, B, C, D T6, ATEX, CE
86538-02
Catalognumber Sensor Range Resolution
Alarm set pointsPrice
Low HighRZ-86538-04 O2 0 to 30% 0.1% 19.50% 23.50% RZ-86538-00 CO 0 to 500 ppm 1 ppm 35 ppm 200 ppm RZ-86538-02 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm RZ-86538-06 SO2 0 to 20 ppm 0.1 ppm 2 ppm 10 ppm RZ-86538-08 NO 0 to 250 ppm 1 ppm 25 ppm 50 ppm RZ-86538-10 NO2 0 to 20 ppm 0.1 ppm 1 ppm 10 ppm RZ-86538-12 Cl2 0 to 10 ppm 0.1 ppm 0.5 ppm 5 ppm RZ-86538-14 HCN 0 to 100 ppm 1 ppm 4.7 ppm 50 ppm RZ-86538-16 NH3 0 to 50 ppm 1 ppm 25 ppm 50 ppm
SpecificationsAlarm: 90 dB at 4 in. (audible/visible/vibrating)Sensor life: 2 yearsFunctions: high/low, STEL, TWA, peak,
low-battery indicatorDisplay: LCD
Power: two AA lithium batteries Battery life: 2 yearsDimensions: 2"W x 31⁄2"H x 1"DInstrument wt: 3.6 oz (0.1kg)
GasAlertClip™ Extreme Personal MonitorsCompact and easy to use—no maintenance required!
Specifications
Approval: UL: Class I, Div. 1, A, B, C, D; Class I, Zone 0, Group IIC CENELEC: EEx ia IICOperated by an advanced microcontroller and electrochemical
sensor, the GasAlertClip Extreme monitors provide continuous, maintenance-free operation for up to two years from the day of activation. These disposable battery-operated monitors are easy to use—simply clip the meter to your pocket or belt and go!
View important gas-reading information and detector life remaining data on the full-feature LCD display. No calibration is required for H2S or CO; O2 self calibrates. Monitors feature audible, visible, and vibrating alarms. Each monitor is encased in a shock- and water-resistant ABS enclosure and offers RFI protection to withstand the rigors of industrial and field use.
GasAlertClip3 Extreme offers the same great features plus a three-year sensor.
What’s included: alligator belt clip and calibration cap.
Alarm: 95 dB at 1 ft (audible/visible/vibrating)
Sensor life: 2 yearsFunctions: low-battery indicator
Display: alphanumeric status panelPower: 3 V lithium battery (included)Dimensions: 2"W x 31⁄4"H x 1"DInstrument wt: 4 oz (0.1 kg)
86383-03
Catalognumber Sensor Range Accuracy
Alarm set pointsPrice
Low HighGasAlertClip with 2-year sensor
RZ-86383-05 O2 0 to 30% ±0.1% 19.5% 23.5% RZ-86383-01 CO 0 to 300 ppm ±1 ppm 35 ppm 200 ppm RZ-86383-03 H2S 0 to 100 ppm ±0.3 ppm 10 ppm 15 ppm RZ-86383-07 SO2 0 to 100 ppm ±1 ppm 5 ppm 10 ppm
GasAlertClip3 Extreme with 3-year sensorRZ-86383-11 CO 0 to 300 ppm ±1 ppm 35 ppm 200 ppm RZ-86383-09 H2S 0 to 100 ppm ±0.3 ppm 10 ppm 15 ppm
GasAlert™ Extreme Single-Gas DetectorsSimple four-button operationThe easy-to-read LCD shows continuous real-time gas concentrations and instrument status. The detectors feature simple auto zero and calibration procedures. All models feature a 90 dB alarm and bright LED to warn you of the presence of hazardous conditions. The LOW, HIGH, and TWA alarms have adjustable set points; peak values can be displayed on demand. The full function self-test
verifies sensor, circuit, and battery integrity and activates the audible/visual/vibrating alarms each time you turn on the instrument.
What’s included: pocket/belt clip, test cap and hose, and 3 V lithium battery.
Approval: UL Class I, Div. 1, Groups A, B, C, D; CE
SpecificationsAlarm
Audible: 95 dB at 1 ft Visual: dual red LEDs Optional: vibrating
Sensor life: 2 yearsFunctions: TWA, peak, adjustable alarm
set points, low battery indicatorDisplay: backlit LCD
Power: 3 V lithium battery (included)Battery life: 2 yearsDimensions: 2"W x 33⁄4"H x 1"DInstrument wt: 4 oz (0.1 kg)
81991-13
Catalog number Sensor Range Resolution
Alarm set pointsPrice
Low HighRZ-81991-15 O2 0 to 30% 0.1% 19.5% 23.5% RZ-81991-11 CO 0 to 999 ppm 1 ppm 35 ppm 200 ppm RZ-81991-13 H2S 0 to 100 ppm 1 ppm 10 ppm 15 ppm RZ-81991-17 SO2 0 to 100 ppm 1 ppm 2 ppm 5 ppm
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
9
Air/Gas Analysis AISingle-Gas / Multigas Detectors
Specifications Gasman Single-Gas MonitorsDatalog and download up to 3000 hours with time and date stampl Rechargeable lithium-ion battery
for 12 hours of operationl Rugged housing is IP 65/67 rated
for dust and water resistanceSmall size and light weight ensure the monitors are comfortable to wear all day long. Visible flashing LED, audible 85 dB, and vibrating alarms quickly alert the wearer to potential gas hazards. Data is recorded by the monitor and can be downloaded to a PC or printer using the adapter/PC interface (sold separately).
What’s included: calibration cap, pocket clip, and rechargeable lithium-ion battery.
Approval: UL and cUL Class I Div. 1 Groups A, B, C, D (pending), ATEX, CE
Alarm: 85 dB (audible), visible, vibrating
Sensor life: 2 yearsFunctions: STEL, TWA, peak hold,
zero, low-battery indicatorDisplay: backlit LCD
Power: rechargeable lithium-ionBattery life: 12 hoursDimensions: 2"W x 4"H x 11⁄4"DInstrument wt: 4 oz (0.1 kg)
RZ-86550-50 Adapter/PC interface, 110 VAC ....................................... RZ-86550-51 Adapter/PC interface, 230 VAC European .....................
Catalognumber Sensor Range Resolution
Alarm set pointsPrice
Low HighRZ-86550-00 O2 0 to 25% 0.1% 19.5% 23.5% RZ-86550-02 CO 0 to 500 ppm 1 ppm 30 ppm — RZ-86550-04 H2S 0 to 250 ppm 1 ppm 5 ppm 20 ppm RZ-86550-06 LEL 0 to 100% 1% 20% LEL — RZ-86550-08 SO2 0 to 10 ppm 0.1 ppm 2 ppm — RZ-86550-10 NO 0 to 100 ppm 1 ppm 25 ppm — RZ-86550-12 NO2 0 to 10 ppm 0.1 ppm 1 ppm — RZ-86550-14 O3 0 to 1 ppm 0.1 ppm 0.5 ppm —
86550-00
X-am 2000 Multigas MonitorsReliable measurements, long life, and easy operation at a low cost of ownershipl Large display allows for readings at a glancel Quick response to combustible gasesl Withstands electromagnetic interferencel Long 5-year sensor lifeThese meters are compact and lightweight—about the size of a mobile phone—providing comfort for long periods of wear. Meter can be easily set up using its straightforward menu and two-button control panel. Gas is sensed through the top or front of the instrument ensuring reliable detection regardless of meter placement or orientation. Robust, IP67-rated design features shock-proof sensors to protect against impact or vibration, and an integrated rubber boot provides dust and water protection even after being immersed in water. The multitone audible alarm, 180° visual alarm, and built-in vibrating alarm ensure wearer does not miss warnings. Meter includes a datalogger to store readings and download via infrared interface to a PC for later analysis.
What’s included: crocodile clip and two AA batteries.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1, Groups A, B, C, D, E, F, G T4; CSA; ATEX; CE
AccessoriesRZ-86515-23 Rechargeable battery kit includes charger module and rechargeable battery pack .............................................................. RZ-86515-24 Bump test station ............................................................ RZ-86515-25 GasVision™ software allows you to chart and graphically display exposure data .......................................................
Sensor Range Resolution Alarm set pointsLow High
Combustibles 0 to 100% LEL 1% LEL 10% 20%O2 0 to 25% 0.1% 19.5% 23.5%CO 0 to 2000 ppm 1 ppm 35 50H2S 0 to 200 ppm 1 ppm 10 ppm 20 ppm
Alarm: 90 dB at 1 ft (audible/visible/vibrating)
Functions: datalogging, STEL, TWA, min/max, low-battery indicator
Sensor life: 5 years Display: LCD
Output: IRPower: two AA batteries (included)Battery life: 12 hoursDimensions: 17⁄8"W x 51⁄8"H x 11⁄4"DInstrument wt: 7.8 oz (0.22 kg)
Catalog number Description PriceRZ-86515-20 Four-gas monitor; O2, LEL, CO, H2S RZ-86515-21 Three-gas monitor; O2, LEL, H2S RZ-86515-22 Three-gas monitor; O2, LEL, CO
Specifications86515-20
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
10
Air/Gas AnalysisAIMultigas Detectors
GasAlertMicroClip™ Multigas DetectorPerformance of a multigas monitor with the feel and simplicity of a single-gas monitorl Simple single-button operation l Simple automatic calibration procedure Lightweight, compact monitor is designed with a rugged housing with concussion-proof boot for your most demanding work environments. Continuous LCD shows simultaneous gas concentrations for H2S, CO, O2, and combustibles. Features four alarm levels: instant low and high alarm level for all gases, TWA and STEL for CO and H2S, and an over-limit alarm. A 95 dB alarm tone, bright alarm bars, and internal vibrating alarm are ideal for high-noise areas. Features a standard datalogger (16 hours) and event logger (10 events) to record TWA, STEL, and maximum exposure to gas and displays on command.
Approval: CSA Class I, Div. 1, Groups A, B, C, D; CE; ATEX
What’s included: belt clip, calibration hose/cap, and lithium polymer battery. Confined-space kit includes IR connectivity kit, aspirator pump, 10-ft sampling hose, calibration hose, 34-L gas cylinder, regulator, and hard carrying case.
Alarm: 95 dB (audible/visible/vibrating)Functions: auto calibration, STEL, TWA,
peak readings, auto backlight, user-selectable field options
Display: backlit LCD
Output: nonePower: lithium poly (included)Battery life: 14 hoursDimensions: 21⁄2"W x 41⁄4"H x 11⁄2"DInstrument wt: 5.6 oz (0.2 kg)
Sensor Range Resolution Accuracy Alarm set points
Low HighCombustibles 0 to 100% LEL 1% LEL ±1% LEL 10% LEL 20% LEL
O2 0 to 30% 0.1% ±0.1% 19.5% 23.5%CO 0 to 500 ppm 1 ppm ±1 ppm 35 ppm 200 ppmH2S 0 to 100 ppm 1 ppm ±1 ppm 10 ppm 15 ppm
Specifications
Catalog number Description PriceRZ-86418-20 Compact multigas detector RZ-86418-22 Compact multigas detector with confined space kit
86418-20
Specifications
GasAlertMax™ Four-Gas DetectorSimultaneously view four gas concentration levels on easy-to-read LCDlPlug-in Versapak® battery is
easy to replace and provides 14 hours of operation
lWide-angled alarm bar is visible from all angles
Detector features internal sampling pump for remote sampling and easy one-button control. Order the confined space kit to ensure safe entry into a confined space.
What’s included: plug-in replaceable sensors, two NiMH rechargeable batteries, two-port charger, 10-ft sampling hose, and holster with belt loop. Confined space kit also includes 34L calibration gas cylinder, calibration hose, regulator, and hard carrying case.
Approval: CSA intrinsically safe for Class I, Division 1, Grade A, B, C, and D, Class I, Zone 0, Grade IIC; CENELEC EEx ia IIC.
Alarm: 95 dB (audible/visible)Functions: auto calibration,
maximum readings, TWA (Time Weighted Average), and auto backlight
Display: backlit LCD
Output: nonePower: two NiMH batteries
with 110 VAC chargerBattery life: 12 hoursDimensions: 3"W x 6"H x 11⁄2"DInstrument wt: 1 lb (0.5 kg)
Kit 81990-22
†Oxygen cell has one-year warranty.
†
Sensor Range Resolution AccuracyAlarm set points
Low HighCombustibles 0 to 100% 1% ±1% 10% 20%
O2 0 to 30% 0.1% ±0.1% 19.5% 23.5%CO 0 to 500 ppm 1 ppm ±1 ppm 35 ppm 200 ppmH2S 0 to 100 pm 1 ppm ±1 ppm 10 ppm 15 ppm
RZ-81990-62 Four-in-one calibration gas cylinder, 58 L ..................... RZ-81990-80 Remote vibrator alarm provides additional protection in high-noise environments ............................................... RZ-81990-74 Battery charger; 230 VAC, European plug ..................... RZ-81990-82 Replacement battery, NiMH ...........................................
Catalog number Description PriceRZ-81990-20 Four-gas detector RZ-81990-22 Four-gas detector with confined-space kit
81990-20
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
11
Air/Gas Analysis AIMultigas Detectors
GasAlertMicro5™ Compact Multigas MonitorsPortable gas detectors simultaneuosly monitor and display up to five gases including O2, combustibles (LEL), and three additional toxic gasesl Integral, concussion-proof
boot and water-resistant design handles rugged environments
l Audible, visible, and vibrating alarm for high-noise areas
l Auto back light in low-light conditions
Water resistant with concussion-proof enclosure, these monitors feature superior design and functionality at a competitive price. Automatically cycles through calibration when turned on. Large, high-contrast LCD shows continuous, real-time gas concentrations. TWA, STEL, and maximum exposure recorded and displayed on command. Additional user-selectable field options include confidence beep, pass-code protection, latching alarm, safe display function, stealth mode, span level, and selectable ppm resolution for SO2 and CL2.
What’s included: belt clip, calibration hose/cap, and two AA batteries. Confined-space kits also include an aspirator pump, 10-ft sampling hose, calibration hose, 34-L gas cylinder, regulator, and hard carrying case.
Approval: CE; CSA Intrinsically safe for Class I, Div. 1, Groups A, B, C, D; CENELEC EEx ia d IIC
Specifications
Alarm: 95 dB (audible/visible/ vibrating)
Functions: auto calibration, STEL, TWA, peak readings, auto backlight, user selectable field options
Display: backlit LCD
Output: nonePower: two AA batteries (included) Battery life: 16 hoursDimensions: 21⁄2"W x 4"H x 11⁄4"DInstrument wt: 7.5 oz (0.2 kg)
Sensor Range Resolution Accuracy Alarm set points
Low HighCombustables 0 to 100% LEL 1% LEL ±1% LEL 10% LEL 20% LEL
O2 0 to 30% 0.1% ±0.1% 19.5% 23.5%CO 0 to 999 ppm 1 ppm ±1 ppm 35 ppm 200 ppmH2S 0 to 100 ppm 1 ppm ±1 ppm 10 ppm 15 ppmSO2 0 to 100 ppm 0.1 ppm ±0.1 ppm 2 ppm 5 ppmCL2 0 to 50 ppm 0.1 ppm ±0.1 ppm 0.5 ppm 1 ppm
DescriptionMonitor only With confined-space kit
Catalog number Price Catalog number PriceO2, CO, H2, SO2, LEL RZ-86418-02 RZ-86418-12 O2, CO, H2, CL2, LEL RZ-86418-04 RZ-86418-14
RZ-09376-01 Replacement batteries, AA. Pack of 4 ..................... /pk
GasAlertMicro™ Compact Multigas MonitorPalm-sized unit displays H2S, CO, O2, and combustibles (LEL) simultaneouslyl Integral, concussion-proof boot for
rugged environmentsl Audible, visible, and vibrating alarm
for high-noise areasl Auto back light in low-light
conditions Rugged monitor features superior design and functionality at a competitive price. Automatically cycles through calibration when turned on. Large, high-contrast LCD shows continuous, real-time gas concentrations. TWA, STEL, and maximum exposure recorded and displayed on command. Additional user-selectable field options include confidence beep, pass-code protection, latching alarm, “calibration due” date, safe display function, stealth mode, and span levels.
What’s included: belt clip, calibration hose/cap, and two AA batteries. Confined-space kit also includes an aspirator pump, 10-ft sampling hose, calibration hose, 34-L gas cylinder, regulator, and hard carrying case.
Approval: CE; CSA Intrinsically safe for Class I,Div. 1, Groups A, B, C, D; CENELEC EEx ia d IIC
Specifications
Alarm: 95 dB (audible/visible/ vibrating)
Functions: auto calibration, STEL, TWA, peak readings, auto backlight, user selectable field options
Display: backlit LCD
Output: nonePower: two AA batteries (included) Battery life: 16 hoursDimensions: 21⁄2"W x 4"H x 11⁄4"DInstrument wt: 7.5 oz (0.2 kg)
86418-00 Compact and lightweight—
fits easily in your hand.
Catalog number Description PriceRZ-86418-00 Compact multigas monitor RZ-86418-10 Compact confined-space kit
Sensor Range Resolution Accuracy Alarm set pointsLow High
Combustibles 0 to 100% LEL 1% LEL ±1% LEL 10% LEL 20% LELO2 0 to 25% O2 0.1% O2 ±0.1% O2 19.5% O2 23.5% O2
CO 0 to 500 ppm 1 ppm ±1 ppm 35 ppm 200 ppmH2S 0 to 100 ppm 1 ppm ±1 ppm 10 ppm 15 ppm
RZ-09376-01 Replacement batteries, AA. Pack of 4 ..................... /pk
86418-02
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
12
Air/Gas AnalysisAIMultigas Detectors
X-am 3000 Four-Gas MonitorBuilt-in remote sampling pump is ideal for confined-space pre-entry samplingl Three distinctive alarms signal the presence of hazardsl Different alarm tones distinguish between pre and main alarml Menus can be password protected to prevent tamperingSmall size and light weight make this monitor ideal for confined-space entry or all-day wear. Large, easy-to-read display quickly indicates gases measured and their concentrations. Monitor features two high-intensity alarm lights, a loud audible alarm, and a vibrating alarm to alert you of hazards even in high-noise areas. Three easy-to-use buttons allow you to power unit, acknowledge alarm, and access features. Rugged, IP65-rated, chemical-resistant polymer housing withstands bumps and drops associated with harsh industrial environments and confined-space entries.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1, Groups A, B, C, D, E, F, G T4; CSA; ATEX; CE; MSHA
AccessoriesRZ-86515-32 Bump test station ............................................................ RZ-86515-33 Battery charger for rechargeable NiMH battery ..........................................................................................
86515-30
Sensor Range ResolutionAlarm set points
Low HighCombustibles 0 to 100% LEL 1% LEL 10% 20%
O2 0 to 25% 0.1% 19.5% 23.5%CO 0 to 2000 ppm 1 ppm 35 50H2S 0 to 200 ppm 1 ppm 10 ppm 20 ppm
Alarm: 90 dB at 1 ft (audible/visible/vibrating)
Functions: STEL, TWA, max readingsSensor life: 2 years Display: LCDOutput: none
Power: rechargable NiMH or two AA batteries
Battery life: 24 hours (diffusion mode), 12 hours (pump mode)
Dimensions: 51⁄2"W x 31⁄2"H x 21⁄4"DInstrument wt: 19.4 oz (0.55 kg)
SpecificationsCatalog number Description Price
RZ-86515-30 Four-gas monitor with sampling pump
RZ-86515-31 Four-gas monitor with confined-space kit and sampling pump
What’s included: belt clip, calibration adapter, pump adapter, filter, 10 ft of Tygon® tubing, and NiMH battery. Confined-space kit includes battery charger, calibration gas, regulator, rubber boot, and hard carry case.
Micro MAX Pro Multigas DetectorsFeatures unique voice assist warnings in four languages for additional safetyl Voice Assist speakerl Loud 90-dB hornl Operates using internal sampling pump or in diffusion model Non-intrusive battery compartmentThese multiple gas detectors are designed to provide the ultimate in personal safety. Functions are accompanied by a verbal voice message. Voice warns of everything from simple on/off function to hazard warnings and alarms—making it an excellent choice for low-light applications. The voice message can be changed to speak English, Spanish, French, or German. When unit goes into alarm, the voice alert is accompanied by 90-dB audible and bright flashing visual alarms. An internal sample draw pump can be used to perform pre-entry testing. The instrument is housed in a rugged case that provides superior RFI/EMI shielding, as well as dust, water, and impact resistance. Designed, tested, and manufactured under strict ISO 9001 standards.
Approval: UL classified for use in Class I, II, III Division I, Groups A, B, C, D, E, F, G
What’s included: rechargeable NiMH battery.
Sensor Range Resolution Alarm set pointsLow High
Combustibles 0 to 100% LEL 1% LEL 10% 20%O2 0 to 30 % 0.10% 19.50% 23.50%CO 0 to 1000 ppm 1 ppm 35 ppm 100 ppmH2S 0 to 200ppm 1 ppm 10 ppm 15 ppmSO2 0 to 100 ppm 1 ppm 2 ppm 5 ppm
Specifications
Alarm: 90 db, voice Functions: TWA, STEL, peak Display: backlit LCD Output: RS-232
Power: rechargeable NiMH battery (included) or four AAA alkaline batteries (not included)
Battery life: 13 hrsDimensions: 43⁄4"W x 3"H x 2"DInstrument wt: 17.6 oz
Catalog number Description Price
RZ-10107-90 Two-gas detector; O2, H2S
RZ-10107-91 Three-gas detector; O2, LEL, CO
RZ-10107-92 Four-gas detector; O2, LEL, CO, H2S
RZ-10107-93 Five-gas detector; O2, LEL, CO, H2S, SO2
10107-92
RZ-09376-00 Batteries, AAA. .............................................. /pack of 4
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
7
Air/Gas Analysis AICMS Analyzer / Single-Gas Detectors
CMS Analyzer and Chips Eliminate user error for a consistent measurement every timelDigital display of gas
concentration eliminates ambiguous results
lInternal recorder stores up to 50 measurements with time/date stamp
Just load a CMS gas specific chip into the bottom port of the analyzer. Easy-to-use, three-step slide switch allows analyzer to take measurements. Gas concentration is displayed in seconds with digital readout. Operates on four AA batteries (included). Chips contain 10 tests each and are sold separately at right.
Approval: UL and CSA listed intrinsically safe for class 1, Div 1, Groups A-D, T4; CENELEC EEx ib IIC T4; MSHA
86513-00
CMS ChipsCatalog number Gas/vapor Range Price
RZ-86513-08 Acetic acid 2 to 50 ppm RZ-86513-09 Acetone 40 to 600 ppm RZ-86513-10 Ammonia 2 to 50 ppm RZ-86513-12 Ammonia 100 to 2000 ppm RZ-86513-14 Benzene 10 to 250 ppm RZ-86513-16 Carbon dioxide 200 to 3000 ppm RZ-86513-18 Carbon dioxide 1 to 20% RZ-86513-20 Carbon monoxide 15 to 150 ppm RZ-86513-22 Chlorine 0.2 to 10 ppm RZ-86513-23 Ethylene oxide 0.4 to 5 ppm RZ-86513-24 Formaldehyde 0.2 to 5 ppm RZ-86513-25 Hydrogen cyanide 2 to 50 ppm RZ-86513-26 Hydrogen sulfide 0.2 to 5 ppm RZ-86513-28 Hydrogen sulfide 2 to 50 ppm RZ-86513-30 Nitrogen dioxide 0.5 to 25 RZ-86513-32 Oxygen 1 to 30% RZ-86513-34 Ozone 25 to 1000 ppb RZ-86513-35 Petroleum hydrocarbons 20 to 500 ppm RZ-86513-36 Petroleum hydrocarbons 100 to 3000 ppm RZ-86513-37 Sulfur dioxide 5 to 150 RZ-86513-38 Toluene 10 to 300 ppm RZ-86513-39 Vinyl chloride 10 to 250 ppm RZ-86513-40 Xylene 10 to 300 ppm
RZ-09376-01 Replacement batteries, AA. Pack of 10 ................... /pk
Specifications for AnalyzerPower: four AA batteries (included)Dimensions: 31⁄2"W x 8"H x 13⁄4"D
Instrument wt: 25.6 oz (0.7 kg)
Catalog number Description PriceRZ-86513-00 CMS analyzer
MSHA
Pac 3000/5000 Single-Gas MonitorsBump test mode—requires user to expose monitor to gas periodically or prior to useThe monitor features a robust, rubber-coated weatherproof polymer housing that will stand up to the typical abuse in an industrial environment. Monitor is maintenance free and can be easily operated using two buttons. Its small size makes it comfortable and easy to wear all day on a belt, breast pocket, or lapel. A loud audible alarm, two bright visual alarms, and strong vibrating alarms alert you to hazardous concentrations of gas.
The Pac 3000 only shows gas formula until the measured value exceeds alarm set point. The Pac 5000 will continuously display gas concentrations, and is equipped with an event logger which will store up to 60 alarm activations or other events.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1, Groups A, B, C, D, E, F, G T4; ATEX; CE
Catalognumber Sensor Range Resolution
Alarm set pointsPrice
Low HighPac 3000 single-gas monitors
RZ-86515-04 O2 0 to 25% 0.1% 19.50% 23.50% RZ-86515-00 CO 0 to 500 ppm 1 ppm 35 ppm 50 ppm RZ-86515-02 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
Pac 5000 single-gas monitorsRZ-86515-14 O2 0 to 25% 0.1% 19.50% 23.50% RZ-86515-10 CO 0 to 500 ppm 1 ppm 35 ppm 50 ppm RZ-86515-12 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
SpecificationsAlarm: 90 dB at 12 inches (audible/visible/vibrating)Sensor life: 2 yearsFunctions: actual concentration, operating time
Display: LCDPower: lithium battery (included)Battery life: 2 years
86515-04
Dimensions: 21⁄2"W x 31⁄4"H x 3⁄4"DInstrument wt: 4 oz (0.1 kg)
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
14
Air/Gas AnalysisAI
Specifications for ToxiRAE Plus Personal PID
Alarm: 90 dB, auto shut off pump at low-flow condition
Functions: instantaneous, average, Short Term Exposure Limit (STEL), and peak value; battery voltage; elapsed time
Display: alarm, darkness, or manually activated backlighted LCD
Detector lamp: 10.6 eV Output: serial (datalogging model only)Power: rechargeable NiMH battery
or four AA alkaline batteries (not included)
Battery life: 10 hoursDimensions: 81⁄4"L x 3"W x 2"HInstrument wt: 19 oz (0.6 kg)
Alarm: 90 dB buzzer and flashing red LED patterns indicate exceeded preset limits: high, low, and Short Term Exposure Limit (STEL) or Time Weight Average (TWA)
Functions: STEL and TWA values of toxic and VOC gases; programmable alarm; battery voltage; elapsed time
Display: 8-digit LED
Detector lamp: 10.6 eVOutput: serial (datalogging model only)Power: rechargeable NiCd battery or
two AA alkaline batteries (not included)
Battery life: 10 hoursDimensions: 6"L x 13⁄4"W x 1"HInstrument wt: 6.4 oz (0.2 kg) Accessories for All Detectors
RZ-86263-52 PID calibration kit includes 100-ppm isobutylene, 34-liter cylinder, and regulator with adapter ................. RZ-86262-50 Lamp cleaning kit ............................................................ RZ-86264-50 Automotive power adapter ............................................ RZ-09376-01 Batteries, AA. Pack of 4 ............................................ /pk
ToxiRAE Plus Personal PID
Both models include rechargeable NiCd battery, single-unit charging station, 110 VAC battery charger, alkaline battery adapter for two AA batteries, and calibration adapter with tubing.
Standard Detector features two operation modes— operate in “display” mode to view instantaneous, STEL, TWA, and peak readings; use password- protected “program” mode to ensure secure alarm and calibration settings.
Datalogging Detector has the same features as the standard model, plus 4000-reading datalogging with time/date stamp and programmable, manual, periodic, or scheduled start/stop. Includes software for Windows® 98, NT, or XP and computer interface cable.
Approval: UL and cUL classified intrinsically safe in Class I, Division 1, Groups A, B, C, D; EEx ia IIC T4; CE.
86261-00
MiniRAE 2000 Survey PIDPowerful, versatile, and user-friendly with a standard operating range of 0 to 10,000 ppm, the MiniRAE 2000 is ideal for many industrial applications. Strong internal pump draws samples up to 100 feet horizontally or vertically. All monitors include 10.6 eV lamp, 5" inlet probe, water trap filter, rubber boot with belt clip, alkaline battery adapter, tool kit, built-in rechargeable NiMH battery for 10 hours of continuous operation, 120 VAC battery charger, wrist strap, operation video, and shipping case.
Standard Detector offers two modes. Use “survey” mode to display instantaneous readings, activate high/low alarms, and store up to 15,000 readings with user ID, site ID, serial number, and time/date stamp. Choose “hygiene” mode to display or record TWA, STEL, and peak levels. Activate separate alarms for each parameter.
Datalogging Detectors have the same features as the standard MiniRAE 2000. Download data and upload instrument setup from a PC through RS-232 link to a serial port. Include cable and software for Windows 98, NT, or XP.
Datalogging Detector with Accessories and Calibration Kit includes lamp cleaning kit, five porous metal filters, O-rings, organic vapor zeroing kit, gas outlet port and tubing, 100 ppm isobutylene calibration gas, 34-liter cylinder, regulator, flow controller, and case.
Approval: UL and cUL classified intrinsically safe in Class I, Division 1, Groups A, B, C, D; EEx ia IIC T4; CE.
86262-15
Specifications for MiniRAE 2000 Survey PID
lElectrodeless 10.6 eV lamp ionizes chemicals for more sensitive concentration readings
lImmediate VOC readings—eliminates costly and time-consuming lab analysis
PID technology provides real-time detection of Volatile Organic Compounds (VOC), hazardous gases, or vapors in parts per million—take immediate safety action in response to excessive exposure instead of waiting days or weeks for lab results.
Choose the pocket-size ToxiRAE monitor for personal monitoring; select the handheld MiniRAE 2000 for environmental, industrial hygiene, health, safety, and plant applications.
Catalog number Description PriceRZ-86262-15 Standard MiniRAE 2000 survey PID RZ-86262-20 Datalogging MiniRAE 2000 survey PID
RZ-86262-25 Datalogging MiniRAE 2000 survey PIDr withaccessories and calibration kit
Catalog number Description PriceRZ-86261-00 Standard ToxiRAE Plus personal PID RZ-86261-10 Datalogging ToxiRAE Plus personal PID
Range Resolution Accuracy0 to 99.9 ppm 0.1 ppm ±10% of reading < 2000 ppm
100 to 10,000 ppm 1 ppm ±20% of reading > 2000 ppm
Photo Ionization Detectors (PID)Photo ionization detector (PID) ensures highly sensitive broad-band toxic gas detection for maximum worker protection
Range Resolution Response time Accuracy0 to 99.9 ppm 0.1 ppm 10 seconds ±10% of reading100 to 2,000 ppm 1 ppm 10 seconds
Gas Detection, PID
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
15
Air/Gas Analysis AI
RZ-81973-50 Calibration kit ........................... RZ-81973-60 RS-232 interface. Includes Windows® 98 software .....................
Accessories
Catalog number Range Resolution Accuracy PriceCO2 monitor
RZ-81973-20 0 to 50,000 ppm (0 to 5%) 100 ppm (0.01%) ±5% reading or ±50 ppm† CO2 analyzer
RZ-81973-00 0 to 10,000 ppm 10 ppm ±5% reading or ±100 ppm† CO2 incubator monitor
RZ-81973-10 0 to 50% 0.01% to 3%, 0.1% above 3% ±5% reading or ±300 ppm† †Whichever is greater
SpecificationsAlarm: audible/visibleDisplay: backlit LCD
Dimensions: 25⁄8"W x 51⁄2"H x 13⁄16"DInstrument wt: 1.7 lb (0.7 kg)
Power: one NiCd rechargeable battery with 110/240 VAC charger (included)
Battery life: 8 hours
81973-20
81973-10
Carbon Dioxide MetersRapid detection of changing CO2 levelsl Maintenance-free pressure and temperature compensated sensorl Ideal for IAQ surveys, food packaging, ventilation verification, and incubator checksCO2 Monitor is a compact and lightweight detection device that immediately responds to excessive levels of CO2—ideal for personal monitoring. Meter features a maintenance- free infrared sensor and audible/visible alarms that respond intermittently to CO2 concentrations above 5000 ppm and continuously to concentrations above 10,000 ppm.
CO2 Analyzer features a dual wavelength pressure and temperature compensated sensor for fast, accurate CO2 measurement. Built-in datalogger stores up to 850 readings—ideal for indoor air quality surveys and ventilation checks. Audible/visual alarm responds intermittently to CO2 concentrations above 5000 ppm and continuously to concentrations above 10,000 ppm.
CO2 Incubator Monitor provides fast, accurate CO2 level monitoring. Features a powerful internal pump for extracting samples; two sampling modes, sample draw and diffusion; integral fan; and maintenance-free dual wavelength pressure and temperature compensated sensors. Keep records of your CO2 levels with the built-in datalogging feature. Choose to log your readings continuously or with the manual snapshot mode. Nonvolatile memory holds approximately 100 snapshot readings and 800 sets of continuous datalogged readings. Download stored readings to your PC for storage or analysis via the infrared data link. Alarm features a variable pitched tone to indicate CO2 levels.
What’s included: one 8-hour continuous-use NiCd battery with 110/240 VAC charger. Model 81973-10 also includes a sampling probe and hose assembly.
Alarm: adjustable audible/visibleDisplay: backlit LCD with graphic displayOperating temperature: –40 to 140°F (–40 to 60°C)System requirements: Windows® 95 or aboveOutput: RS-232, 0 to 1 VDC
Data storage: 2700 pointsPower: rechargeable NiMH battery
with 115 VAC adapterDimensions: 31⁄8"W x 77⁄8"H x 15⁄8"D Instrument wt: 2 lb (0.9 kg)
Specifications
86437-00
Catalog number Range Resolution Accuracy PriceRZ-86437-00 0 to 2000 ppm 1 ppm ±20 ppm CO2 + 2% of reading RZ-86437-02 0 to 20% 0.01% ±0.02% CO2 + 2% of reading
lIntuitive, menu-driven display with shortcut buttons for easy operation lQuickly store and datalog up to 2700 readingsLow-maintenance, high-accuracy CO2 sensor only requires calibration every two years. Backlit display shows reading both numerically and graphically—store data in memory or download to PC via RS-232. Includes a second probe port—order optional temperature/humidity probe to expand measurement capabilities (sold separately below).
Ideal for applications including: laboratory fume hood checks, industrial hygiene studies, spot measurement of food and beverage storage/lines, and HVAC monitoring.
What’s included: CO2 probe, rechargeable battery with 115 VAC adapter, software, RS-232 cable, and manual.
Approval: Meter: IP54; Probe: IP65 (NEMA 4), CE
Compliance: EN 61326-1:1997 for electromagnetic compatibility
RZ-37301-90 Optional temperature/humidity probe ...................................................................
Datalogging Carbon Dioxide MetersSilicone-based infrared sensor ensures superior stability over time and temperature
Air Quality, Carbon Dioxide
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
16
Air/Gas AnalysisAI
Air Quality MetersSimultaneously monitor temperature, humidity, carbon dioxide, and carbon monoxidelEasy, menu-driven operation—no training requiredlUser-selectable alarm settings to alert operator when readings reach the programmed levelVersatile monitors combine the basic functionality of a temperature/humidity meter with expanded gas monitoring capabilities for your most complete portable IAQ tool. These compact, multiparameter instruments are ergonomically designed for handheld use or use the flip-out stand for stand-alone monitoring. Audible, visible, and internal vibrating alarms indicate when readings reach a particular level—you can step away from the instrument during testing.
What’s included: RTD probe, rechargeable lithium ion battery with 115 VAC charger/adapter, manual, and soft carrying case. Datalogging model also includes software.
Alarm: 85 dB/red LED (audible/visible) and internal vibrating alarm
Display: backlit, multiparameter LCDOperating temperature:
–4 to 122°F (–20 to 50°C)
Power: rechargeable 16-hour lithium ion battery with 115 VAC charger/adapter (included)
Battery life: 16 hoursDimensions: 31⁄2"W x 611⁄16"H x 11⁄2"DInstrument wt: 15 oz (0.4 kg)
Specifications
Catalog number Description PriceRZ-86439-00 Air quality meter RZ-86439-10 Air quality meter with datalogging
Parameter (sensor) Range Resolution AccuracyCO2 (infrared) 0 to 250 ppm; 0 to 500 ppm (selectable) 1 ppm ±3% of readingCO (electrochemical) 0 to 500 ppm; 0 to 10,000 ppm (selectable) 1 ppm ±3% of readingTemperature (RTD) 32 to 104°F (O to 40°C) 0.1°F (0.1°C) 0.2°F (0.1°C)RH (capacitive polymer) 0 to 95% 1% ±2% of reading
86439-01Features one-button
calibration
RZ-93831-70 Optional RTD probe for secondary temperature .......................................................................... RZ-86384-50 Calibration kit for 86384-01 ............................................. RZ-86384-51 Calibration kit for 86384-11 ............................................. RZ-09376-01 Replacement batteries, AA. Pack of 4 ..................... /pk
IAQ-Calc™ Meters Easy-to-use keypad scrolls through all readings at the touch of a buttonlLow-drift NDIR CO2 sensor gives stable, accurate readingslCheck building IAQ conditions to optimize productivitylIdeal for testing HVAC system performance
The IAQ-Calc CO2 Meter provides cost- effective CO2 measurements. The sampling function records multiple point measurements.
The IAQ-Calc Advanced IAQ Meter calculates % outside air from either CO2 or temperature readings and directly calculates dew point, wet bulb temperature, absolute humidity, and humidity ratio. The dual-line display simultaneously displays multiple parameters. Datalogger logs up to 26,900 samples with time/date stamp. The included LogDat2™ software permits easy transfer of data to your computer and the LogDat2 Companion for Excel® automatically graphs all your data.
What’s included: NIST-traceable certificate, carrying case, and batteries. Model 86384-15 also includes probe and AC adapter.
Catalog number Description PriceRZ-86384-05 IAQ-Calc CO2 meter (measures CO2 only) RZ-86384-15 IAQ-Calc advanced IAQ meter
Specifications
Display: multiparameter LCDOperating temperature:
41 to 158°F (5 to 70°C)System requirements: Windows® 3.1
or Windows 95 or higher
Power: four AA batteries (included) or 115 VAC adapter (included with 86384-11)
Dimensions: 4"W x 611⁄16"H x 11⁄2"DInstrument wt
Model 86384-01: 12 oz (0.4 kg) Model 86384-11: 17 oz (0.5 kg)
†Applies to the advanced IAQ meter only.
Parameter Range Resolution Accuracy
CO2 0 to 5000 ppm 1 ppm ±3% of reading or±50 ppm, whichever is greater
CO† 0 to 500 ppm 0.1 ppm ±3% of reading or±3 ppm, whichever is greater
RH† 5 to 95% 0.1% ±2%
Temperature† 32 to 140°F(0 to 60°C)
0.1°F(0.1°C)
±1.0°F(±0.6°C)
% outside air† 0 to 100% 0.1% —
86384-11
GO to page(s) 731–748
For our complete line of humidity products, go to pages 731–748
Air Quality, IAQ Meters
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
17
Air/Gas Analysis AI
RZ-86316-61 Ozone calibrator (0.1 ppm) ..............................................................................................
86316-30
Pocket Ozone DetectorAccurate, easy-to-read digital displayl Versatile meter can be used for fixed or portable monitoringl Ideal for leak checks in generators, valves and pipingThe heated metal oxide semiconductor has a range of 0.02 to 10 ppm; digital readout is in 0.01 ppm increments. Use as a permanent monitor indoors when the concentration average is below 0.1 ppm; use outdoors or at concentrations up to 10 ppm for short periods of time. Includes rechargeable batteries, charger, and carrying case.
Order optional calibrator to verify that your ozone monitor is conforming to the original calibration. Calibrator recalibrates detector at 0.1 ppm. It measures 21⁄4"W x 33⁄4"H x 1"D and includes a 9 V battery.
Display: LCD Power: rechargeable batteries with a charger (included) Dimensions: 2"W x 4"H x 1"D
Specifications
RZ-86316-61 Ozone calibrator (0.1 ppm) ............................................................................................... RZ-09376-04 Replacement battery, 9 V. Pack of four ..................................................................... /pk
Continuous Ozone MonitorsFixed or portable systems alert workers to hazardous ozone levelsl Easy-to-read, multicolor graphical displayl HMOS sensor for superior sensitivityLED bar graph changes color as ozone levels increase: green indicates a safe level, yellow is caution level, and red is the danger level. Both models feature a heated metal oxide semiconductor (HMOS) sensor for excellent sensitivity and quick response time. Order optional calibrator to verify that your ozone monitors are conforming to their original calibration.
Fixed Ozone Monitor with Alarm has an audio alarm that is triggered at 0.1 ppm (danger level). Features include a connection for external equipment control. Portable Ozone Monitor can be permanently installed for on-site use or carried with you to detect leaks throughout your plant.
Display: LED color bar graphOutput: 0 to 3 VDCDimensions: 23⁄8"W x 31⁄4"H x 13⁄8"D
Power Model 86316-10: AC adapter (included) Model 86316-20: rechargeable eight hour NiMH battery and an AC adapter/recharger (included) 86316-10
Display 86316-20
Specifications
86487-00
Display: green/red indicator lightOutput: 250 VAC, 5 A
Power: 12 to 24 VDC power supplyDimensions: 31⁄2"W x 3"H x 13⁄4"D
Specifications
RZ-86316-61 Ozone calibrator (0.1 ppm) ..............................................................................................
Ozone Relay SwitchMonitors ozone levels to control ozone generators and alarm relaysl User adjustable setpoint—select appropriate ozone level to meet your needsl Ideal for use as leakage alarm in water treatment plants, food storage and processing,
semiconductor manufacturing, and sterilization areas.Switch is housed in rugged, ABS plastic case that is easily mounted to any wall or inside air ducts. HMOS sensor detects the presence of ozone in 0.03 to 1 ppm range. Simply configure alarm set point to desired level—switch has red visible indicator and activates relay when level is exceeded. Switch operates on 12 to 24 VDC power supply and features SPDT nonlatching relay output.
LED provides visual indication when ozone level
is exceeded.
Catalog number Description Range Price
RZ-86316-10 Fixed ozone monitor with alarm 0.02 to 0.14 ppm (0.2 to 0.30 or more ppm with an external data readout)
RZ-86316-20 Portable ozone monitor 0.02 to 0.14 ppm
Catalog number Description Range PriceRZ-86316-30 Ozone detector 0.02 to 10 ppm
Catalog number Description Range PriceRZ-86487-00 Ozone relay switch 0.03 to 1 ppm
Ozone Detectors
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
18
Air/Gas AnalysisAI
86392-00
AirAware Fixed-Gas MonitorsEasy to use—single button calibration and fresh air zero functions!lBright LCD shows instantaneous concentrations of gas.lBroad gas ranges with quality sensorsLow/high alarm settings alert workers of potential gas hazards. Basic monitor plugs easily into any AC outlet—no installation required. Models with 4 to 20 mA output have dual relays to trigger remote alarms/ sirens, turn on fans, or shut down a process.
Approval: CSA
SpecificationsPower
Monitors: 120 VAC Monitors with output: 12 to 24 V AC/DC
Dimensions: 31⁄8"W x 51⁄4"H x 25⁄8"D
Alarm: 85 dB (audible/visual)Functions: continuous monitoring, one-button calibration,
fresh-air zeroOutput: 4 to 20 mA and 5 A SPDT relays (86392-10, -12, -14 only)
Sensor Range ResolutionAlarm set points Monitor Monitor with 4 to 20 mA outputLow High Catalog number Price Catalog number Price
O2 0 to 30% 0.1% 19.5% 23.5% RZ-86392-00 RZ-86392-10 CO 0 to 500 ppm 1 ppm 3 ppm 70 ppm RZ-86392-02 RZ-86392-12 Cl2 0 to 100 ppm 0.1 ppm 0.5 ppm 1 ppm — — RZ-86392-14
Dimensions: 23⁄8"W x 31⁄2"H x 13⁄8"D
86316-00
Datalogging VOC Detector with AlarmPrevent health hazards by detecting leaks and poor air quality earlyl Detects acetone, methylene chloride, naphtha, trichloroethylene, and morel Ideal for laboratories, paint/print shops, and woodworking facilitiesUse this economical VOC detector wherever solvents are present. The sensor is highly sensitive to VOCs and solvent vapors. The LED bar graph displays the hazard level of gas or vapor—green indicates normal, yellow for caution, and red for danger. An audible alarm also alerts you to dangerous levels. Responds in one minute. A rechargeable NiCd battery lets you take the detector anywhere—trace leaks to their source. Features include a 0 to 2 VDC output for datalogging and a connection for external equipment control.
Display: LED color bar graphOutput: 0 to 2 VDC
SpecificationsPower: rechargeable NiCd battery
with an AC adapter/charger (included)
Catalog number Description Range† PriceRZ-86316-00 VOC detector with alarm 50 to 100 ppm
†For most solvent based VOCs.
81949-00
Leak Hunter Plus™ Gas Leak DetectorMicrovolume thermal conductivity cells provide the most sensitive leak detection possiblel LCD with nine-segment bar graph displays exact leak rateMeasure any gas with a thermal conductivity different from the surrounding air in cc/sec, cc/min, cu ft/min, or ppm. To operate, simply select calibration data for one of twelve gases and take your readings. Audible alarm changes frequency according to leak rate.
What’s included: 8"L detachable probe, flexible probe extension (increases probe length to 16"), probe clip for one-handed operation, built-in stand with nonskid feet, one 9 V NiCd rechargeable battery, AC adapter/charger, and carrying case.
Detection limits
Specifications
Probe: 8" detachableFunctions: peak hold, autoranging
(for maximum sensitivity), low- battery, and cell failure indications
Power: 9 V NiCd battery (included)Battery life: 8 hrsInstrument wt: 3.3 lb (1.5 kg)
Group Gas Sensitivity
1 H2 8.10 x 10–6 cc/secHe 1.00 x 10–5 cc/sec
2 Neon 5.80 x 10–5 cc/secXenon 5.81 x 10–5 cc/sec
3
R11 6.84 x 10–5 cc/secR12 7.90 x 10–5 cc/secR21 7.98 x 10–5 cc/secR22 9.46 x 10–5 cc/sec
4
CH4 1.06 x 10–4 cc/secAr 1.37 x 10–4 cc/sec
CO2 1.53 x 10–4 cc/secH2O vapor 1.75 x 10–4 cc/sec
Catalog number Power Probelength Dimensions Price
RZ-81949-00 115 VAC 8" 3"W x 63⁄4"H x 1"D RZ-81949-05 220 VAC
Fixed-Gas Detectors
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
19
Air/Gas Analysis AI
CheckPoint O2 and O2 /CO2 AnalyzersMeasure gas levels in modified atmosphere packages (MAP) in just 10 secondslInternal memory function stores up to 10 testslBattery powered for up to 2400 measurementsCompact, handheld CheckPoint analyzer packs excellent functionality in a portable, easy-to-use instrument. Simply use probe assembly to penetrate package to be sampled. Powerful, internal pump draws 15-mL sample and displays gas concentration level in seconds on bright, 3-digit LED display. Memory function allows you to store up to 10 readings to be recorded later. Auto-calibration feature ensures quick calibration at the touch of a button. Analyzer will power off automatically after one minute of inactivity to save battery life. Display hold option enables you to lock the display for easy readability.
Analyzers are encased in a rugged, anodized aluminum housing with IP53 rating for impact and splash resistance. Integrated needle holder prevents accidental sticks when probe is not in use. Select from single O2 or combined O2/CO2 model to suit your application.
What’s included: sampling probe assembly, ten septa, ten replacement needles and filters, four AA batteries, and NIST-traceable calibration certificate.
Sensor type O2: electrochemical CO2: infrared (86490-02 only)
Specifications
Catalog number Description Range Resolution Accuracy Price
RZ-86490-00 CheckPoint O2 0 to 100% 02 0.1% ±0.1% (0 to 5%),±2% (5 to 100%)
RZ-86490-02 CheckPoint O2 /CO20 to 100% O2
0 to 100% CO20.1%
O2: ±0.1% (0 to 5%),±2% (5 to 100%);
CO2: ±0.2% (0 to 10%),±2% (10% to 100%)
Catalog number Description Range Resolution Accuracy Power (VAC, Hz) PriceRZ-86490-20 CheckMate II O2 10 ppm to 100% 0.10% ±1% of reading 115, 50/60
RZ-86490-21 CheckMate II O2/CO2O2: 10 ppm to 100%
CO2: 0 to 100%O2: 0.1%
CO2: 0.1%O2: ±1% of reading;
CO2: ±2% FSD 115, 50/60
Sampling pump: 200 mBar max vacuum pump
Sampling assembly: probe with integral needle holder and sampling hose
Power: four AA batteries (included)
Dimensions: 3"W x 52⁄3"H x 21⁄2"D
Sensor type O2: ceramic solid state CO2: infrared
SpecificationsSampling pump: built-in, automatic
sample drawSampling assembly: probe with integral
needle holder and sampling hose
86490-02
Needle and probe are
conveniently stored inside meter case
when not in use.
Icon-based, smart keys allow hassle-free operation.
86490-21
CheckMate II O2 and O2 /CO2 AnalyzersConfigure up to five hundred customized product testing programslLogging of more than 10,000 test resultslDownload data via built-in USB portlLAN monitor capabilitylRequires only a small sample volume — use for both food and pharmaceutical
headspace measurements.Benchtop CheckMate II analyzers are fast, reliable, and easy to use. Powerful units require only 2-mL O2 or 5-mL CO2 sample volume. Gas sampling starts automatically as syringe is introduced to the package for fail-safe operation. Sensor features water trap system to maintain sensor integrity. Gas levels display in 5 seconds on backlit LCD.
Use icon-based smart keys to customize sampling, alarms, and data recording parameters for up to 500 different product types. Complete documentation of test results with time/date stamp can be sorted and printed immediately, or stored for download later to computer. Analyzers feature self-diagnostics to monitor operation and prevent common user errors. Select from single O2 or combined O2/CO2 model to suit your application.
What’s included: sampling probe assembly, ten septa, ten replacement needles, five replacement sampling hoses, ten water trap filters, two rolls of replacement printer paper, USB stick for download, and NIST-traceable calibration certificate.
Dimensions: 117⁄8"W x 7"H x 85⁄8"D
Headspace Analyzers, O2 / CO2
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.
20
Air/Gas AnalysisAI
Display 10360-70
Headspace O2/CO2 AnalyzersMeasure the amount of oxygen in food packaging to ensure product quality and safetyl Save time and money by preventing spoilage Use these analyzers to measure residual oxygen in gas-flushed CAP/MAP food packages. Analyzers resist nitrogen and carbon dioxide—commonly used as background gases in packaging. Calibrate the units by sampling room air—normal air reading is 20.9% oxygen. Durable sensor in the analyzer has excellent zero and span stability after calibration.
Handheld Oxygen AnalyzerThis handheld analyzer is compact and lightweight so you can take it anywhere you need to measure residual oxygen levels in packages. Use a sampling probe assembly with a needle to pierce through the package. A built-in pump draws and delivers a sample to the sensor. Analyzer can also be used for applications where the oxygen level is very high (50 to 100%), without overloading the sensor. Other features include auto shut-off after 45 minutes of nonuse and low-battery indication.
What’s included: one sampling probe assembly, two needles, one syringe filter, two septas, four rechargeable NiCd batteries, and a charger with 115 VAC adapter.
Note: analyzer must always be used with rechargeable NiCd batteries.
SpecificationsSensor type: electrochemical cellSampling pump: internal with
adjustable timer from 5 to 10 secondsSampling assembly: probe with
male luer connection for side-port needle, coiled PTFE tubing
Power: four AA NiCd rechargeable batteries (included)
Battery life: 8 hoursDimensions: 4"W x 8"H x 13⁄4"D
Handheld analyzer 10360-20
Accessories for Both Analyzers
RZ-10360-24 Replacement sampling probe assembly ....................... RZ-10360-26 Replacement needles, side-port hole. Pack of three .................................................................................... /pk RZ-10360-28 Replacement septa provide leak-tight seal upon needle penetration. Pack of 200 ........................................... /pk
Benchtop O2 /CO2 AnalyzerUse this benchtop analyzer for continuous package testing in the laboratory or at the packing line. Analyzer features a heavy-duty, maintenance-free sensor that compensates for slight temperature variations. Unlike other sensors, accuracy is not affected by flow rate, heat, or hydrocarbon gases.
Model 10360-30 is used to sample food packs, insert the needle tip of the probe into the food pack through a foam seal pad. Seal pad provides a tight seal and prevents air from leaking into the package through the puncture hole. Press the pump button to draw a sample from the package. The built-in pump draws in the precise amount of sample required for analysis, then turns off after a pre-set sampling time.
Pharmaceutical oxygen headspace analyzer (model 10360-60) is ideal for measuring headspace oxygen in vials.
Select model 10360-70 for oxygen and carbon dioxide testing. 10360-70 features a solid state infrared sensor for measuring CO2 as well as electrochemical cell for O2.
What’s included: sampling probe assembly, needle, syringe filter, small pack of septa, NiCd battery, and a 115 VAC adapter.
Benchtop analyzer 10360-30
Sensor type: heavy-duty electrochemical O2 cell; Infrared CO2 sensor (model 10360-70 only)
Sampling pump: miniature diaphragm type with adjustable timer from 1 to 10 seconds
Sampling assembly: probe/needle holder for luer needle with side hole; disposable filter, 1⁄16" OD inert tubing.
Power: 115 VAC or rechargeable NiCd battery (included)
Battery life: 8 hoursDimensions: 10"W x 4"H x 93⁄4"D
Specifications
Catalog number Range Resolution Accuracy PriceRZ-10360-20 0.1 to 100% oxygen 0.1% ±1%
Catalog number Range Resolution Accuracy PriceRZ-10360-30 0.1 to 100% O2 0.1% O2 ±0.1% RZ-10360-60 0.1 to 100% O2 0.1% O2 ±0.1%
RZ-10360-70 0.1 to 100% O2, 0.1 to 100% CO2
0.1% O2, 0.1% CO2
±0.1%
Headspace Analyzers, O2 / CO2
scientifica, inc.1221 Brickell Avenue Suite 900 Miami, FL 33131www.scientificainc.com
Phone: +305-669-0731 Fax: +305-667-9805
selling sc iencescientifica inc.