air conditioning technical data - daikintech.co.ukfna)/2016/fnq-a... · air conditioning technical...

17
Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A

Upload: dangkien

Post on 28-Nov-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

Air Conditioning

Technical DataConcealed floor standing unit

EEDEN15-100

FNQ-A

Page 2: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A
Page 3: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Split - Sky Air • FNQ-A 1

• Indoor Unit • FNQ-A

TABLE OF CONTENTSFNQ-A

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

6 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Sound Power Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Sound Pressure Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

10 Fan characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Page 4: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

1

2

1 Features

oor Unit it - Sk -A cealed f

Ind Spl FNQ Con Designed to be concealed in walls

• Ideal for installation in offices, hotels and residential applications

• Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

• Its low height (620 mm) enables the unit to fit perfectly beneath a window

• Requires very little installation space as the depth is only 200mm

• High ESP allows flexible installation

Home leave operation

Fan only Auto cooling-heating

changeover

Fan speed steps

Dry programme Air filter Weekly timer Infrared remote control

Wired remote control

Centralised control

Auto-restart Self diagnosis Twin/triple/double twin application

Multi model application

VRV for residential application

• Split - Sky Air • FNQ-A

Page 5: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

3

2

• Indoor Unit • FNQ-A

2 Specifications

Notes

(1) Including installation legs

The sound power level is an absolute value indicating the power which a sound source generates.

2-1 Technical Specifications FNQ25A FNQ35A FNQ50A FNQ60A

Cooling capacity Nom. kW 2.6 3.4 5.0 6.0Heating capacity Nom. kW 3.2 4.0 5.8 7.0Casing Colour Unpainted

Material Galvanised steel plateDimensions Unit Height/Width/

Depthmm 620 / 720 (1)/750/200 620 / 720 (1)/1,150/200

Packed unit Height/Width/Depth

mm 265/925/885 265/1,325/885

Weight Unit kg 23 30Packed unit kg 27 35

Air filter Type Resin net with mold resistanceFan Type Sirocco fan

Quantity 2 4Air flow rate Cooling High m³/min 8.7 16.0

Nom. m³/min 8 14.8Low m³/min 7.3 13.5

Heating High m³/min 8.7 16.0Nom. m³/min 8 14.8Low m³/min 7.3 13.5

External static pressure

High Pa 48 49Nom. Pa 30 40

Fan motor Quantity 1Model KFD-280-44-8A KFD-280-65-8ASpeed Steps 3Output Rated W 44 65

Sound power level Cooling dBA 53 56Heating dBA -

Sound pressure level Cooling High/Nom./Low dBA 33/31/28 36/33/30Heating High/Nom./Low dBA 33/31/28 36/33/30

Refrigerant Type R-410AGWP 2,087.5

Piping connections Sound absorbing insulation Butyl RubberLiquid Type/OD mm Flare connection/6.35Gas Type/OD mm Flare connection/9.52 Flare connection/12.7Drain VP20 (I.D. 20/O.D. 26)Heat insulation Foamed polystyrene / Foamed polyethylene

2-2 Electrical Specifications FNQ25A FNQ35A FNQ50A FNQ60A

Power supply Phase 1~Frequency Hz 50/60Voltage V 220-240/220

• Split - Sky Air • FNQ-A 3

Page 6: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

3

4

3 Safety device settings3 - 1 Safety Device Settings

• Split - Sky Air • FNQ-A

Page 7: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

3

4

• Indoor Unit • FNQ-A

4 Options4 - 1 Options

• Split - Sky Air • FNQ-A 5

Page 8: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

5

6

5 Dimensional drawings5 - 1 Dimensional Drawings

• Split - Sky Air • FNQ-A

Page 9: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

3

6

• Indoor Unit • FNQ-A

6 Centre of gravity6 - 1 Centre of Gravity

310

100

700

200

285

620

• Split - Sky Air • FNQ-A 7

Page 10: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

6

8

6 Centre of gravity6 - 1 Centre of Gravity

1100

475

620

100285

200

• Split - Sky Air • FNQ-A

Page 11: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

3

7

• Indoor Unit • FNQ-A

7 Piping diagrams7 - 1 Piping Diagrams

• Split - Sky Air • FNQ-A 9

Page 12: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

8

10

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

• Split - Sky Air • FNQ-A

Page 13: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

3

9

• Indoor Unit • FNQ-A

9 Sound data9 - 1 Sound Power Spectrum

NotesdBA = A weighted sound power level (A scale according to IEC).Reference acoustic intensity 0dB = 10E 6 W/m2Measured according to ISO 3744

1.2.3.

FNQ25 35A

NR0

NR5 NR10 NR15 NR20

NR25

NR30

NR35

NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

NR80

NR85

NR90

10

20

30

40

50

60

70

80

90

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

63 125 250 500 1000 2000 4000 8000 dBA

Soun

dpo

wer

level[dB

]

Octave band centre frequency [Hz]

Cooling mode

High tap

3D096615

NotesdBA = A weighted sound power level (A scale according to IEC).Reference acoustic intensity 0dB = 10E 6 W/m2Measured according to ISO 3744

1.2.3.

FNQ50 60A

NR0

NR5 NR10 NR15 NR20

NR25

NR30

NR35

NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

NR80

NR85

NR90

10

20

30

40

50

60

70

80

90

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

63 125 250 500 1000 2000 4000 8000 dBA

Soun

dpo

wer

level[dB

]

Cooling mode

Octave band centre frequency [Hz]

High tap

3D096616

• Split - Sky Air • FNQ-A 11

Page 14: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

9

12

9 Sound data9 - 2 Sound Pressure Spectrum

Fan speed

High

Medium

Low

NotesData is valid at free field condition.Data is valid at nominal operation condition.dBA = A weighted sound pressure level (A scale according to IEC).Reference acoustic pressure 0 dB = 20 μPa

Soun

dpressure

level[dB

]

1.2.3.4.

Octave band centre frequency [Hz]Soun

dpressure

level[dB

]

Cooling Heating

FNQ25 35A

Octave band centre frequency [Hz]

NR0

NR5NR10NR15

NR20NR25

NR30

NR35NR40

NR45NR50NR55

NR60NR65NR70

NR75NR80NR85

NR90

10

20

30

40

50

60

70

80

90

1015202530354045505560657075808590

63 125 250 500 1000 2000 4000 8000 dBA

NR0

NR5

NR10NR15

NR20NR25

NR30

NR35NR40

NR45NR50NR55

NR60NR65NR70

NR75NR80NR85

NR90

10

20

30

40

50

60

70

80

90

1015202530354045505560657075808590

63 125 250 500 1000 2000 4000 8000 dBA

Microphone

Unit

Duct

3D096733

Fan speed

High

Medium

Low

NotesData is valid at free field condition.Data is valid at nominal operation condition.dBA = A weighted sound pressure level (A scale according to IEC).Reference acoustic pressure 0 dB = 20 μPa

Soun

dpressure

level[dB

]

1.2.3.4.

Octave band centre frequency [Hz]

Soun

dpressure

level[dB

]

Cooling Heating

FNQ50 60A

Octave band centre frequency [Hz]

NR0NR5NR10NR15

NR20NR25

NR30

NR35NR40

NR45NR50

NR55

NR60NR65NR70

NR75NR80NR85

NR90

10

20

30

40

50

60

70

80

90

1015202530354045505560657075808590

63 125 250 500 1000 2000 4000 8000 dBA

NR0NR5NR10NR15

NR20NR25

NR30

NR35NR40

NR45NR50

NR55

NR60NR65NR70

NR75NR80NR85

NR90

10

20

30

40

50

60

70

80

90

1015202530354045505560657075808590

63 125 250 500 1000 2000 4000 8000 dBA

Microphone

Unit

Duct

3D096734

• Split - Sky Air • FNQ-A

Page 15: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

3

10

• Indoor Unit • FNQ-A

10 Fan characteristics10 - 1 Fan Characteristics

• Split - Sky Air • FNQ-A 13

Page 16: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

• Indoor Unit • FNQ-A

10

14

10 Fan characteristics10 - 1 Fan Characteristics

• Split - Sky Air • FNQ-A

Page 17: Air Conditioning Technical Data - daikintech.co.ukFNA)/2016/FNQ-A... · Air Conditioning Technical Data Concealed floor standing unit EEDEN15-100 FNQ-A • Split - Sky Air • FNQ-A

Daikin Europe N.V. participates in the Eu-rovent Certification programme for LiquidChilling Packages (LCP), Air handling units(AHU), Fan coil units (FCU) and variable re-frigerant flow systems (VRF) Check ongo-ing validity of certificate online:www.eurovent-certification.com or using:www.certiflash.com

EE

DE

N1

5-1

00

0

4/1

5

Co

pyrig

ht D

aiki

n T

he

pre

sent

pu

blic

atio

n s

up

erse

des

EE

DE

N1

4-1

00

The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.has compiled the content of this leaflet to the best of its knowledge. Noexpress or implied warranty is given for the completeness, accuracy, re-liability or fitness for particular purpose of its content and the productsand services presented therein. Specifications are subject to changewithout prior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or re-lated to the use and/or interpretation of this leaflet. All content is copy-righted by Daikin Europe N.V.

BARCODE Daikin products are distributed by:

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende