EFFECTS OF APRIL 2000 REVISION OF API 14.3 PART 2 ORIFICE METER TUBES

Upload: anonymous-xv4altzu

Post on 05-Feb-2016

462 views

Category:

Documents


22 download

DESCRIPTION

Emerson document on the changes to AGA3

TRANSCRIPT

Page 1: Aga 3 -2000 Revision

EFFECTS OFAPRIL 2000

REVISION OFAPI 14.3 PART 2

ORIFICE METERTUBES

Page 2: Aga 3 -2000 Revision

CHANGES TO API 14.3 - APRIL 2000CHANGES TO API 14.3 - APRIL 2000

INTERNAL SURFACE FINISH

UPSTREAM LENGTH

STRAIGHTENING VANES

FLOW CONDITIONERS

8” PLATE THICKNESS

THERMOWELL LOCATION

STAGGERED TAPS

P LEAD LINES

INCREASED DIFFERENTIAL

GRANDFATHER CLAUSE

Page 3: Aga 3 -2000 Revision

INTERNAL FINISHINTERNAL FINISH

WAS 250 MICROINCH THROUGHOUT

CHANGES TO API 14.3 - APRIL 2000

•NOW SIZE AND BETA DEPENDENT

Page 4: Aga 3 -2000 Revision

METER TUBES TO 12” SIZE

CHANGES TO API 14.3 - APRIL 2000

INTERNAL SURFACE FINISH

Page 5: Aga 3 -2000 Revision

METER TUBES 16” & LARGER

INTERNAL SURFACE FINISH

CHANGES TO API 14.3 - APRIL 2000

Page 6: Aga 3 -2000 Revision

THOUGH UNDESIRABLE, ARE NOW ALLOWED,IF THEY DON’T

→EXCEED I.D. TOLERANCE

→EXCEED FINISH REQUIREMENT

PITS

CHANGES TO API 14.3 - APRIL 2000

Page 7: Aga 3 -2000 Revision

UPSTREAM LENGTH SELECTIONUPSTREAM LENGTH SELECTION

→BARE TUBE ( no vane or conditioner)

→SHORT TUBE WITH VANE

→LONG TUBE WITH VANE

→TUBE WITH CONDITIONER

4 CATEGORIES

Page 8: Aga 3 -2000 Revision

CATEGORY ( no vane or conditioner )

NOW IS 145D

UNIVERSAL “CATCH ALL” METER TUBE

Page 9: Aga 3 -2000 Revision

CATEGORY Bare Meter Tubes continued,

Shorter Lengths Possible For Specific Installations

CATEGORY Bare Meter Tubes continued,

Shorter Lengths Possible For Specific Installations

→Single 90º Elbow @ .75β ---44D

→(2) 90’s Out of Plane (close coupled) @ .5β --95D

→Concentric Reducer @ .75β --13D

→Tee (used as an elbow-not header) @ .75β --44D

Page 10: Aga 3 -2000 Revision

See

detail

CATEGORY

NO VANE OR

CONDITIONER

Page 11: Aga 3 -2000 Revision

MAX .46 BETA

CATEGORY SHORT VERSION WITH VANE

UNIVERSAL METER TUBE WITH VANE

Page 12: Aga 3 -2000 Revision

SHORT UPSTREAMLENGTH WITH TUBE

BUNDLE

COMPARISON OFOLD AND NEW

REQUIREMENTS

CATEGORY

Page 13: Aga 3 -2000 Revision

CATEGORY

Short upstream

with tube bundle

Page 14: Aga 3 -2000 Revision

CAREGORY LONG VERSION WITH VANE

MAX .67 BETA

UNIVERSAL METER TUBE WITH VANE

Page 15: Aga 3 -2000 Revision

CATEGORY

LONG UPSTREAM

WITH TUBE BUNDLE

Page 16: Aga 3 -2000 Revision

LONG UPSTREAMLENGTH WITH TUBE

BUNDLE

COMPARISON OF OLDAND NEW

REQUIREMENTS

CATEGORY

Page 17: Aga 3 -2000 Revision

THE METER TUBE LENGTH INFORMATION

CONTAINED IN THIS REVISION WAS BASED ON

THE RESULTS OF ACTUAL FLOW TESTING AT

12 LABS (DOMESTIC AND INTERNATIONAL),

USING BOTH LIQUID AND GAS.

CHANGES TO API 14.3 - APRIL 2000

Page 18: Aga 3 -2000 Revision

CHANGES TO API 14.3 - APRIL 2000

TUBE BUNDLE STRAIGHTENING VANES

Page 19: Aga 3 -2000 Revision

19 CONCENTRIC SAME SIZE TUBES

NEW, TIGHTER TOLERANCES

TUBE BUNDLE STRAIGHTENING VANES

CHANGES TO API 14.3 - APRIL 2000

CONCENTRIC PATTERN

Page 20: Aga 3 -2000 Revision

HEX PATTERN

NOT ALLOWED

TUBE BUNDLE STRAIGHTENING VANES

HEX PATTERN

CHANGES TO API 14.3 - APRIL 2000

Page 21: Aga 3 -2000 Revision

END BANDS

NOT ALLOWED

TUBE BUNDLE STRAIGHTENING VANES

CHANGES TO API 14.3 - APRIL 2000

END BANDS

Page 22: Aga 3 -2000 Revision

7 TUBE BUNDLE

NOT ALLOWED

TUBE BUNDLE STRAIGHTENING VANES

CHANGES TO API 14.3 - APRIL 2000

7 TUBE BUNDLE FOR 2” SIZE

Page 23: Aga 3 -2000 Revision

FLOW CONDITIONINGFLOW CONDITIONING

Page 24: Aga 3 -2000 Revision

FLOW CONDITIONERS

REMOVE SWIRL AND CREATE A NEAR

FULLY DEVELOPED FLOW PROFILE

CHANGES TO API 14.3 - APRIL 2000

Page 25: Aga 3 -2000 Revision

THE DANIEL PROFILERTM

CONDITIONER PLATE

Page 26: Aga 3 -2000 Revision

Profiler™ Installation

Page 27: Aga 3 -2000 Revision

METER TUBE WITH PROFILER

CHANGES TO API 14.3 - APRIL 2000

Page 28: Aga 3 -2000 Revision

Meter tube upstream lengthsand beta ratio limits for usewith all flow conditionersother than the standard tubebundle will be established bythe manufacturer based onrequired testing

(ref. Par. 2.5.5.4 AGA-3/API 14.3 April2000)

CHANGES TO API 14.3 - APRIL 2000

Page 29: Aga 3 -2000 Revision

THE USE OF FLOWCONDITIONERS MAY ALLOWSHORTER UPSTREAM PIPELENGTHS

BUTA SERIES OF TESTS MUST BE RUNBEFORE OFFERING THE DEVICETO THE MARKET

CHANGES TO API 14.3 - APRIL 2000

Page 30: Aga 3 -2000 Revision

Disturbance TestsDisturbance Tests

→Good Flow Conditions

→Two 900 Elbows in Perpendicular Planes

→Gate Valve 50% Closed

→High Swirl

CHANGES TO API 14.3 - APRIL 2000

Flow Conditioner Qualification Test

Page 31: Aga 3 -2000 Revision

CHANGES TO API 14.3 - APRIL 2000

Flow Conditioner Qualification Test

•Good Flow Conditions - test evaluating impact of flowconditioner on fully developed velocity profile.

•Install the conditioner in the specified location preceding ameter tube where the installation has been shown to alreadyhave a swirl free, fully developed profile. This proves thedevice has no negative effect on flow.

Page 32: Aga 3 -2000 Revision

•Two 900 Elbows in Perpendicular Planes - testing of flowconditioner performance in handling combination of a modestswirl and a non-symmetrical velocity profile.

CHANGES TO API 14.3 - APRIL 2000

Flow Conditioner Qualification Test

Page 33: Aga 3 -2000 Revision

Gate Valve 50% Closed - test evaluating flow conditionerperformance in strongly non-symmetrical velocity profile

CHANGES TO API 14.3 - APRIL 2000

Flow Conditioner Qualification Test

Page 34: Aga 3 -2000 Revision

•High Swirl - test assessing flow conditioner performancein flows with high swirl angle (over 250).

CHANGES TO API 14.3 - APRIL 2000

Flow Conditioner Qualification Test

Swirl must be reduced to 2º Max

Page 35: Aga 3 -2000 Revision

Additional TestsAdditional Tests

– Orifice β ratio: Check swirl test at β=0.40 andβ=0.67

– Reynolds Number Sensitivity: Test at tworanges 10,000 < Re <500,000 and Re > 1MMwith approximately a 7:1 ratio.

– Scaling: Test at two sizes selected from D < 4” and D > 8”

Flow Conditioner Qualification Test

CHANGES TO API 14.3 - APRIL 2000

Page 36: Aga 3 -2000 Revision

ANY FLOW CONDITIONERCHOSEN SHOULD HAVE TESTDATA SHOWING COMPLIANCEWITH THE TESTING PROGRAMOUTLINED IN AGA/14.3

CHANGES TO API 14.3 - APRIL 2000

Page 37: Aga 3 -2000 Revision

CHANGES TO API 14.3 - APRIL 2000CHANGES TO API 14.3 - APRIL 2000

WAS 12” TO 36” UPSTREAM OF VANE

NOW IS 36” MINIMUM UPSTREAM OF VANE

UPSTREAM THERMOWELL LOCATION

Page 38: Aga 3 -2000 Revision

STAGGERED PRESSURE TAPSSTAGGERED PRESSURE TAPS

NOT ALLOWED

CHANGES TO API 14.3 - APRIL 2000

STAGGERED PRESSURE TAPS

Page 39: Aga 3 -2000 Revision

PLATE THICKNESS CHANGE

→8” SIZE WAS 1/8” THICK

→NOW IS 1/4” THICK

CHANGES TO API 14.3 - APRIL 2000

Reason: differential was limited to 150” in an orifice fitting

Page 40: Aga 3 -2000 Revision

→Some 1/8” and 1/4”seal/plate assemblies may beinterchangeable in the samefitting, allowing installation ofthe wrong plate in the rightfitting

CHANGES TO API 14.3 - APRIL 2000

IMPACT OF 8” PLATE CHANGE TO 1/4” THICK

Page 41: Aga 3 -2000 Revision

→Plate carriers and/or seal rings forsome manufacturers’ fittings maybe different for 1/8” and 1/4” thickplates

CHANGES TO API 14.3 - APRIL 2000

IMPACT OF 8” PLATE CHANGE TO 1/4” THICK

Page 42: Aga 3 -2000 Revision

→Existing installations using1/8” thick plates will requirecareful organization if 1/4”units are added

IMPACT OF 8” PLATE CHANGE TO 1/4” THICK

CHANGES TO API 14.3 - APRIL 2000

Page 43: Aga 3 -2000 Revision

PLATE THICKNESS CHANGE

→24” SIZE WAS 3/8” THICK

→NOW IS 1/2” THICK

CHANGES TO API 14.3 - APRIL 2000

Reason: differential was limited to 150”

Page 44: Aga 3 -2000 Revision

DP TAP CONNECTION LINE LENGTHS

CHANGES TO API 14.3 - APRIL 2000

Page 45: Aga 3 -2000 Revision

→EQUAL LENGTH LINES

→SHORT AS POSSIBLE

DP TAP CONNECTION LINE LENGTHS

CHANGES TO API 14.3 - APRIL 2000

Page 46: Aga 3 -2000 Revision

DIFFERENTIAL TAP LINE LENGTHDIFFERENTIAL TAP LINE LENGTH

IF RESONANCE OR PULSATION IS SUSPECTED,– CALCULATE PROPER LENGTH USING THESE 5 EQUATIONS BASED ON

PULSATION FREQUENCY (f) AND SPEED OF SOUND IN FLUID (a)

length L = factor x a / (2 B f )

0.25

2.5

5.5

8.5

11.5

THE RESULTING LENGTH NEAREST THAT PREFERRED SHOULD BE USED

CHANGES TO API 14.3 - APRIL 2000

DP TAP CONNECTION LINE LENGTHS

Page 47: Aga 3 -2000 Revision

INCREASED DIFFERENTIAL PRESSUREINCREASED DIFFERENTIAL PRESSURE

TABLES SHOWING MAXIMUM DP FORRECOMMENDED PLATE THICKNESSES

– 304SS AND 316SS

– TEMPERATURES TO 150ºF (65ºC)

– INSTALLED IN BOTH FITTINGS AND FLANGES• FLANGES ALLOW MUCH HIGHER DIFFERENTIALS

CHANGES TO API 14.3 - APRIL 2000

INCREASED DIFFERENTIAL PRESSURES

Page 48: Aga 3 -2000 Revision

INCREASED DIFFERENTIAL PRESSURECONTINUEDINCREASED DIFFERENTIAL PRESSURECONTINUED

SOME SIZES ALLOW UP TO 1000” DP

– VALUES BASED ON PLATE DEFLECTION ONLY

– ANY OPERATIONAL EFFECTS ON ORIFICE FITTINGS NOTCONSIDERED

ADDITIONAL TABLES FOR OTHER THAN STANDARD PLATETHICKNESSES IN APPENDIX

CHANGES TO API 14.3 - APRIL 2000

INCREASED DIFFERENTIAL PRESSURES

Page 49: Aga 3 -2000 Revision

CHANGES TO API 14.3 - APRIL 2000CHANGES TO API 14.3 - APRIL 2000

POSSIBLEEFFECT OFDIFFERENTIALPRESSURESEXCEEDINGVALUESSHOWN

INCREASED DIFFERENTIAL PRESSURES

Page 50: Aga 3 -2000 Revision

GRANDFATHER CLAUSE

From API 14.3 Part 2, Par 2.1, April 2000

CHANGES TO API 14.3 - APRIL 2000

Page 51: Aga 3 -2000 Revision

It is strongly recommended that a copyof the new standard be obtained andread thoroughly as there are manydetails not covered in this presentation

It is strongly recommended that a copyof the new standard be obtained andread thoroughly as there are manydetails not covered in this presentation

CHANGES TO API 14.3 - APRIL 2000

Page 52: Aga 3 -2000 Revision

THE ENDTHE END

CHANGES TO API 14.3 - APRIL 2000

Page 53: Aga 3 -2000 Revision

TAP HOLE LOCATION TOLERANCE FROM 14.3

Page 54: Aga 3 -2000 Revision

HOW TO MEET 14.3 WITH A 1/4” THICK PLATE IN A FITTINGDRILLED FOR A 1/8” THICK PLATE

4” & LARGER

LIMIT BETA

TO .6

Page 55: Aga 3 -2000 Revision
Page 56: Aga 3 -2000 Revision

If distance “S” between 2 fittings is 22D or more,only the fitting nearest the orifice is considered

2.6.3.1

CHANGES TO API 14.3 - APRIL 2000

Page 57: Aga 3 -2000 Revision