Affinity ® NT OXYGENATION SYSTEM Clearly the Choice for Consistent Performance and Reliable Results

Upload: others

Post on 27-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Affinity® NT OxygeNATiON SySTem

Clearly the Choice for

Consistent Performance and Reliable Results

Page 2: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Indication: The oxygenator is indicated for use in an extracorporeal circulation circuit to oxygenate and remove carbon dioxide from the blood and to cool and warm the blood during cardiopulmonary bypass procedures up to 6 hours in duration.

Smart Design that

Sets the Standard for Oxygenators

Consistent performance starts with an oxygenator design that has set the standard for the industry. The Affinity NT’s radial flow design and proprietary fiber winding technique provide the reliable results you desire in a constantly changing cardiac surgery environment.

Continued optimization in the manufacturing process contributes to the consistent performance you have come to expect. With over 4 million oxygenators produced on a single manufacturing line, you—and your patients—can rest assured. The goal of our precision manufacturing is to minimize surprises for you in the operating room.

Page 3: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Pre-membrane Access Port• engineered to facilitate

easy prime

• Provides ability to measure pre-membrane pressure

• Offers option for hemoconcentrator access

Proprietary Graduated Fiber Bundle Density Technology and Radial Flow Design Provides:• enhanced gas transfer

• Low pressure drop

• Short, uniform blood flow path

• Avoidance of areas of stasis

Exact Alignment of Potting Material • Designed to prevent air from being trapped

above recirculation port for easy prime

Unique Radial Flow Design • intended to eliminate performance

variation because fiber bundle is not force fit into case

Metal Bellows Heat Exchanger• Consistent performance with

minimal pressure drop

Affinity—the first oxygenator with a radial blood flow design and use of computational flow dynamics to optimize the blood flow path.

Affinity—the only oxygenator with graduated fiber winding technique for optimized bundle efficiency and manufacturing consistency.

Page 4: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Versatile Cardiotomy Turret

• 3/8" and 1/4" filtered ports for priming ease

• multiple filtered luer ports

• Cardiotomy ports on rotating turret

• Rotating turret easily clears manifold

Simple Drop-in Holder• Articulated design is

compatible with left- and right-hand setup

Hollow Fiber Oxygenator

• Plasma resistant fiber intended for greater resistance to plasma breakthrough

• Total visibility pre-membrane and post-membrane for your priming confidence

Coatings

• Available with heparin biocompatible surfaces

Optimum Operating Levels

• maximum capacity of 4000 ml for maximum patient versatility

• Low minimum operating level of 200 ml

• Designed for excellent low-level visualization with color-coded volume measurements and low-level warning label

Excellent Air Handling Capabilities

• Separate venous and cardiotomy inlets

• Designed to prevent blood contact with defoamer unless foam is present

• Final screen provides additional barrier intended to remove air and other emboli

Page 5: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Totally Clear Design for

Unobstructed Visibility of Blood, gas and Water Phases

Removable Sampling Manifold

• High-flow stopcocks and color-coded sampling lines

Optimal Visibility Achieved

• Clear lid and the elimination of “outer sock” design

• excellent visibility of venous inlet column on the outside of the cardiotomy

Vacuum-Assisted Venous Drainage (VAVD) Compatible

• A negative/positive pressure-relief valve is built into the lid -150 mm Hg/0-5 mm Hg, which features a special obturator valve cap engineered to ensure valve patency

• Non-venting caps for ease of set-up for VAVD procedures (except inlet, outlet, vacuum and recirculation caps)

0 2 4 6 8

Qblood (L/min)

O2 (

mL/

min

)

500

400

300

200

100

0

O2 Transfer Rate

FiO2 100%80%60%

gas:blood �ow = 1:1

0 2 4 6 8

Qblood (L/min)

E

0.9

0.8

0.7

0.6

0.5

0.4

0.3

Heat Exchange E�ectiveness

10.014.018.0

Qwater (L/min)

0 2 4 6 8

Qblood (L/min)

CO2 (

mL/

min

)

500

400

300

200

100

0

CO2 Transfer Rate

.5:1

1:1

2:1Qgas:Qblood

0 2 4 6 8

Qblood (L/min)

∆P (m

m H

g)

100

80

60

40

20

0

Blood Side Pressure Drop

Affinity NT Bench Test Performance information*

* Representative of an uncoated Affinity NT. Bench data on file. Not necessarily predictive of clinical performance results.

Page 6: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Heparin biocompatible surfaces offered on medtronic oxygenation systems

mimic critical characteristics of the vascular endothelium.

Around the world, leading cardiovascular

surgery teams adopt biocompatible surfaces

as a critical component of comprehensive,

multi-modality strategies to achieve the best

possible outcomes for their patients undergoing

extracorporeal circulation.

Warning: A strict anticoagulation protocol should be followed and anticoagulation should be routinely monitored during all procedures. The benefits of extracorporeal support must be weighed against the risk of systemic anticoagulation and must be assessed by the prescribing physician. Contraindication: This device used for any other purposes than for the indicated use is the responsibility of the user. Warning: gas emboli must be cleared from the extracorporeal circuit before initiating bypass. gas emboli are hazardous to the patient. if leaks are observed during priming and/or operation, this may result in air embolism to the patient and/or fluid loss. The extracorporeal circuit must be continually monitored. Do not use the device if these conditions are observed. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. For a complete listing of indications, contraindications, precautions and warnings please refer to the instructions For Use which accompany each product. * Carmeda® is manufactured under license from Carmeda AB for use only as part of an extracorporeal blood circulation system or circuit that

includes an oxygenator or blood pump. Carmeda is a registered trademark of Carmeda AB. ** Technology licensed under agreement from Biointeractions, Limited, United Kingdom.

Surface Design for Performance, Carmeda®* BioActive Surface and Trillium®** Biosurface

Page 7: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

Device Surface

Device Surface

Schematic provided for illustrative purposes and is not to scale.

Schematic provided for illustrative purposes and is not to scale.

Trillium® Biosurface Trillium** Biosurface provides a blood-contacting surface with heparin, a negative charge and hydrophilic properties.

Carmeda® BioActive SurfaceFeaturing durable, non-leaching, End Point Attached Heparin, Carmeda* BioActive Surface has the largest body of peer-reviewed clinical and scientific evidence of any biocompatible surface used for cardiopulmonary bypass today. it is an important component of routine as well as complex extracorporeal circulation procedures.

Platelet

Thrombin

Antithrombin

Covalent Bond

PEO Chain

Heparin

Sulphate/Sulfonate Group

Heparin Active Sequence

End Point Attached Heparin

Platelet

Prime Coat

Prime Coat

Platelet

Platelet

• Non-leaching heparin molecules are covalently bonded onto the surface using an end Point Attachment process

• The end Point Attached method assures that the heparin active binding sites are properly oriented to remain free to participate in biological reactions, similar to the orientation of heparan sulfate molecules naturally found on the vascular endothelium

• A high degree of bioactivity is consistently delivered due to the unique Carmeda® BioActive Surface chemistry and its sophisticated manufacturing process

• Non-leaching heparin molecules are covalently bonded into the surface

• Sulphate and sulfonate groups are incorporated into the Trillium® Biosurface functional layer to provide a negatively charged surface

• Polyethylene oxide (PeO) chains are a component of the functional layer. PeO chains are extremely hydrophilic along the entire chain, creating an “insulating” water layer structure between the blood and artificial surface

Page 8: Affinity NT - arcos.com.uyarcos.com.uy/pdf/productos/9/770_200101366d_en.pdf · Vacuum-Assisted Venous Drainage (VAVD) Compatible • A negative/positive pressure-relief valve is

For information on other Medtronic technologies for extracorporeal circulation, blood processing and diagnostics, visit: www.perfusion.medtronic.com

World Headquarters Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879

Medtronic USA, Inc. Toll-free: 1 (800) 328-2518 (24-hour technical support for physicians and medical professionals)

LifeLine CardioVascular Technical Support Tel: (877) 526-7890 Tel: (763) 526-7890 Fax: (763) 526-7888 E-mail: [email protected]

www.medtronic.com

OxygenatorProduct Number Product Description Units/

case

511 Affinity NT® Hollow Fiber Oxygenator (uncoated) 4

511T Trillium® Affinity NT® Hollow Fiber Oxygenator 4

CB511 Carmeda® Affinity NT® Hollow Fiber Oxygenator 4

Oxygenator w/ReservoirProduct Number Product Description Units/

case

541 Affinity® Hollow Fiber Oxygenator with integrated Affinity CVR 2

541T Trillium® Affinity NT® Hollow Fiber Oxygenator with uncoated integrated Affinity® CVR 2

541TT Trillium® Affinity NT® Hollow Fiber Oxygenator with integrated Trillium® Affinity® CVR 2

CB541 Carmeda® Affinity NT® Hollow Fiber Oxygenator with (non-coated) integrated CVR 2

ReservoirsProduct Number Product Description Units/

case

540 Affinity® CVR Cardiotomy/Venous Reservoir with Filter 4

540T Trillium® Affinity® CVR Cardiotomy/ Venous Reservoir with Filter 4

321 Affinity Venous Reservoir Bag 8

mVR800 mVR Venous Reservoir Bag • 800 ml 6

mVR1600 mVR Venous Reservoir Bag • 1600 ml 6

CBmVR800 Carmeda® mVR Venous Reservoir Bag • 800 ml 6

CBmVR1600 Carmeda® mVR Venous Reservoir Bag • 1600 ml 6

UC200101366d eN © medtronic, inc. 2011

All Rights ReservedPrinted in USA

Affinity NT OxygeneratorMembrane Type: microporous Polypropylene Hollow FibersMembrane Surface Area: 2.5 m2

Static Priming Volume: 270 mlRecommended Blood Flow Rate: 1-7 L/minMaximum Water Side Pressure: 30 psiArterial Outlet Port: 3/8"Venous Inlet Port: 3/8"Arterial Sample Port: Female Luer PortAccess Port: Female Luer PortRecirculation Port: 1/4"Gas Inlet Port: 1/4"Gas Outlet Port: 3/8" NonbarbedWater Ports: 1/2" Quick Disconnects(Right- and left-hand orientations available when connected to the Affinity CVR NT Reservoir)

Affinity CVR NTReservoir Volume Capacity: 4000 mlRecommended Blood Flow Rate: 1-7 L/minMinimum Operating Level: 200Cardiotomy Filtration: 30-micron filterVenous Inlet Screen: 200 micronFinal Reservoir Screen: 150 micronSize: Adult

Affinity Venous Reservoir BagReservoir Capacity: 1250 mlFaceplate Volume Settings: Setting 1: 900 ml Setting 2: 550 mlScreen: 105 micronVenous Inlet: 1/2"Venous Outlet: 3/8"Recirculation: 1/4"Cardiotomy Inlet: 3/8"

MVR Venous Reservoir Bag MVR800 MVR1600

Reservoir Capacity: 800 ml 1600 mlFaceplate Volume Settings: Setting 1: 450 ml 700 ml Setting 2: 650 ml 1200 mlScreen: 105 micron 105 micronVenous Inlet: 1/2" 1/2"Venous Outlet: 3/8" 3/8"Recirculation: 1/4" 1/4"Cardiotomy Inlet: 3/8" 3/8"