1Other applicable documentationGeneral Information
1 General Information1.1 Other applicable documentation
This document supplements the MOVIPRO® operating instructions and limits theapplication notes according to the following information. Only use this document inconnection with the MOVIPRO® operating instructions.
2 Function Units2.1 Power section
The following information has been added to the chapter "Unit structure" / "Functionunits" / "Power section":
2.2 Communication and control unitThe following information has been added to the chapter "Unit structure" / "Functionunits" / "Communication and control unit":
3 Electrical Installation3.1 Connection block
P F A - MD .. - BG 02 - ..Brake control voltage:02 = DC 24 V
P F H - .. - B 64 - ..Bus connection type:64 = 2 × Push-pull SCRJ
3457668875[1] X4234_11 Ethernet fieldbus (Push-pull SCRJ)[2] X4234_12 Ethernet fieldbus (Push-pull SCRJ)
[1] [2]
Addendum to the Operating Instructions – MOVIPRO®
34
4 lectrical connectionsperation
3.2 Electrical connections3.2.1 X4234: Ethernet fieldbus
The following table informs about this connection:
4 Operation4.1 Status LEDs FO1 and FO2 Ethernet connection push-pull SCRJ
The two LEDs "FO1" and "FO2" indicate the signal quality of the respective optical trans-mission line.
The following figure shows the positions of the two LEDs:
Function
Ethernet fieldbus interface, SCRJ / POF
Connection type
Push-pull SCRJ
Wiring diagram
3419100299
Assignment
No. Name Function
1 Tx Transmitting line (POF)
2 Rx Receiving line (POF)
1 2
4083348491[1] FO1[2] FO2
LED status Status or cause of error Remedy
Off The signal level is 2 dB or more. The signal quality is good. –
Lights up yellow
The optical signal level has fallen below 2 dB.This can have the following reasons:• Aging effect of the polymer fiber• The plug connector is not properly
connected.• The externally connected cable is
faulty or damaged.
• Check whether the plug connector is properly connected.
• Check the attenuation of the exter-nally connected cable.
[1] [2]
EO
Addendum to the Operating Instructions – MOVIPRO®
5Version with operating point 400 V/50 HzTechnical Data
5 Technical Data5.1 Version with operating point 400 V/50 Hz
The following information has been added to the technical data:
5.2 Brake control5.2.1 DC 24 V
MOVIPRO®
Size Size 0 Size 1 Size 2
Performance class 2.2 kW 4.0 kW 7.5 kW 11.0 kW 15.0 kW
Ambient temperature
ϑ A
+5 – +40 °C (+41 – +104 °F), Non-condensing, no moisture condensation;
The unit provides intrinsic thermal safety.
(PN reduction: 3% per K up to a maximum of 60 °C or 50 °C in units with push-pull SCRJ)
Brake control DC 24 V
Brake voltage VB DC 24 V
Nominal output current IN DC 1.4 A
Acceleration current IB –
Max. output power PO 33 W
Brake type The data refer to SEW brakes BP01 – BP5(single-coil system, no acceleration)