Addendum No.2_840680 Page 1 ADDENDUM No. 2 Owner: Allendale Charter Township Project: Wastewater Treatment System 2020 Improvements Date: June 26, 2020 Engineer: Fleis & VandenBrink Engineering, Inc. Engineer’s Project No.: 840681 Construction Manager: F&V Construction Management, Inc. CM’s Project No.: 840681 NOTICE TO ALL PROSPECTIVE BIDDERS DRAWING SHEETS ISSUED HEREWITH: E3.1; E6.0; E8.1; E9.2 BIDS DUE: until 2:00 p.m. local time, Wednesday, July 1, 2020 (UNCHANGED) -- ISSUED TO ALL PLANHOLDERS ===================================================================================== This Addendum is a part of the Contract Documents and modifies the previously issued Bidding Documents. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may result in rejection of this Bid. SPECIFICATION CHANGES: ITEM NO. 1: Section 00 52 00 – Agreement 1. Delete “control panel” from the grinder pump station item in the Base Bid Work for Contract 1 – Site Work & Excavation. Clarification: The control panel for the grinder pump station will be provided by Contract 12 – Owner’s System Integrator. 2. Delete “Provide fencing around condenser unit.” from the Base Bid Work for Contract 1 – Site Work & Excavation. Clarification: The work was removed in Addendum No. 1. 3. Delete “Provide pipe heat tracing, thermostats, and related items.” from the Base Bid Work for Contract 10 – Electrical, Controls & Instrumentation. Clarification: Heat tracing is not required on the project. ITEM NO. 2: Section 21 00 00 – Fire Protection 1. Delete Paragraph 2.02.D.3 and replace with the following: “3. Use grooved connections for 2-1/2 inches or larger and schedule 40 threaded or schedule 10 grooved connections for 2 inches and under.” 2. Section 2.02.E Clarification: Hard piping pendent sprinklers to the ceiling is also acceptable.

Upload: others

Post on 10-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

Addendum No.2_840680 Page 1

ADDENDUM No. 2

Owner: Allendale Charter Township Project: Wastewater Treatment System 2020 Improvements Date: June 26, 2020 Engineer: Fleis & VandenBrink Engineering, Inc. Engineer’s Project No.: 840681 Construction Manager: F&V Construction Management, Inc. CM’s Project No.: 840681

NOTICE TO ALL PROSPECTIVE BIDDERS

DRAWING SHEETS ISSUED HEREWITH: E3.1; E6.0; E8.1; E9.2

BIDS DUE: until 2:00 p.m. local time, Wednesday, July 1, 2020 (UNCHANGED) -- ISSUED TO ALL PLANHOLDERS

=====================================================================================

This Addendum is a part of the Contract Documents and modifies the previously issued Bidding Documents. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may result in rejection of this Bid.

SPECIFICATION CHANGES: ITEM NO. 1:

Section 00 52 00 – Agreement 1. Delete “control panel” from the grinder pump station item in the Base Bid Work for

Contract 1 – Site Work & Excavation. Clarification: The control panel for the grinder pump station will be provided by Contract 12 – Owner’s System Integrator.

2. Delete “Provide fencing around condenser unit.” from the Base Bid Work for Contract 1 –

Site Work & Excavation. Clarification: The work was removed in Addendum No. 1.

3. Delete “Provide pipe heat tracing, thermostats, and related items.” from the Base Bid

Work for Contract 10 – Electrical, Controls & Instrumentation. Clarification: Heat tracing is not required on the project.

ITEM NO. 2:

Section 21 00 00 – Fire Protection 1. Delete Paragraph 2.02.D.3 and replace with the following:

“3. Use grooved connections for 2-1/2 inches or larger and schedule 40 threaded or schedule 10 grooved connections for 2 inches and under.”

2. Section 2.02.E Clarification: Hard piping pendent sprinklers to the ceiling is also acceptable.

Page 2: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

Addendum No.2_840680 Page 2

ITEM NO. 3:

Section 23 81 00 – Air Cooled Condensing Unit

1. Add Paragraph 3.03.C: “The manufacturer shall employ a Factory Certified Technician (employed by the manufacturer) within 20 miles of the job site to perform start-up, owner training and labor during the warranty period.”

ITEM NO. 4:

Section 26 32 14 - Gas Engine Generators:

1. Paragraph 2.01.A: Delete “Model C125 N6” and replace with “Model C150 NG”.

2. Delete Paragraph 2.02.A.1 and replace with the following:

“Capacity: 150 KW, 480/277 volt, 3-phase, 4-wire system with a minimum motor starting

alternator KVA rating of 607 KVA at 90% of sustained voltage.”

ITEM NO. 5:

Section 26 36 23 - Automatic Transfer Switches;

1. Paragraph 2.02.G.1: Delete “225 amp” and replace with “260 amp”.

ITEM NO. 6: Section 27 20 00

1. Add the following to Paragraph 1.05.B: “4. Windemuller 5. Shoreline 6. CS Erickson”

ITEM NO. 7:

Section 28 20 00 - Surveillance System:

1. Delete Paragraph 1.05.E and replace with the following:

“E. The VSS shall consist of four (4) digital video cameras. There will be three (3) outdoor mounted cameras suitable for mounting on the Administration and Lab building and one (1) outdoor mounted camera suitable for mounting on lighting pole. The system shall be wired for an additional pole mounted camera in the location show. The system shall be sized to allow for a minimum of four (4) additional cameras in the future without additional hardware or licensing.”

ITEM NO. 8:

Section 40 95 10 - Process Control Panels:

1. Add paragraph 2.04.F:

“F. All control panels shall include a surge suppressor on the incoming 480VAC feeder. Surge suppression device shall be UL 1449 Edition 3 compliant. Surge suppressor shall be MOV type and rated for 40KA. Transtector, Bussman, Erico or approved equal.”

DRAWING CHANGES: ITEM NO. 9:

SHEET C2.2 – Site Utility Plan 1. Add the following note where the proposed electric crosses the sidewalk to the Existing

Maintenance Building: “REMOVE AND REPLACE EXISTING SIDEWALK FOR DUCT BANK INSTALLATION”

ITEM NO. 10:

SHEET M8.2 – Mechanical Details 1. On the Gas Meter Detail: Change gas demand from “1665 CFH” to read “1915 CFH”.

The pipe size to the generator is not changed.

Page 3: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

Addendum No.2_840680 Page 3

2. On the Generator Piping Detail: Change gas demand from “1665 CFM” to read “1915 CFH”.

ITEM NO. 11:

SHEET E1.1 – Enlarged Electrical Site Plan 1. Add call out to ACCU-1 located north of the Mechanical Room and show conduit

between ACCU-1 and the building. ITEM NO. 12:

SHEET E3.1 – Maintenance and Equipment Storage Building Lighting Plans (Re-issued) 1. Revise Plan Note 4 to read as follows:

“4. WASH BAY IS A WET LOCATION. PROVIDE PVC COATED CONDUIT AND WET LOCATION FITTINGS. ELECTRICAL RACEWAY AND JUNCTION BOXES IN SPACE TO BE WATERTIGHT AND CORROSIONRESISTANT.”

ITEM NO. 13:

SHEET E6.0 – Electrical Single-Line Diagram (Re-issued) 1. Changes to increase size of components. 2. Changes to clarify ownership of service equipment.

ITEM NO. 14:

Sheet E8.0 – Electrical Details 1. Delete the following note from Detail 6: In-Ground Handhole Detail.

“DRAIN TO NEAREST MANHOLE WITH SUMP PUMP. SIZE AS REQUIRED 2” MINIMUM.”

ITEM NO. 15:

Sheet E8.1 – Electrical Details (Re-issued) 1. Revise Duct Bank Key items P1 and P5.

ITEM NO. 16:

Sheet E9.2 – Fire Alarm, Surveillance, and County Network Riser Diagram (Re-issued) 1. Revise the Fire Alarm System Riser Diagram to include devices in the Equipment

Storage Building. 2. Add the following to Plan Notes:

“4. PROVIDE COAX SURGE PROTECTION DEVICE FOR POLE MOUNTED CAMERAS IN THE IT ROOM. LOCATE THE SPD IN THE CABLE BEFORE THE CABLE ENTERS THE IT-RACK.”

CLARIFICATIONS:

1. Contract 12 – Owner’s System Integrator is to provide the scope of work outlined in Section 40 95 10 Process Control Panels. This work should not be included Contract 10 – Electrical, Controls & Instrumentation.

2. The bid opening is still planned to be held at the Township Hall. The total number of attendees may be limited due to current health and safety guidelines related to Covid19.

Page 4: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

Addendum No.2_840680 Page 4

Revisions to any of the Contract Documents made by this Addendum shall be considered as the same revision to any and all related areas of the Contract Documents not specifically called out in this Addendum. FLEIS & VANDENBRINK ENGINEERING, INC. Mike Vander Ploeg, P.E. Attachments:

Sheet E3.1 - Maintenance and Equipment Storage Building Lighting Plans Sheet E6.0 – Electrical Single-Line Diagram Sheet E8.1 – Electrical Details Sheet E9.2 – Fire Alarm, Surveillance, and County Network Riser Diagram

Page 5: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

EQUIPMENTSTORAGE

G-1

G-1D

G-1C

1 2 3 4 5 6

A

B

C

D

G-1B

G-1A

STORAGE101

OFFICE103

RESTROOM102

NEW WASHBAY

E

D

C

B

A

1 2 3 4

104

M-1

F&V PROJECT NO.

DESIGNTEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

ALL

END

ALE

CH

AR

TER

TO

WN

SHIP

OTT

AW

A C

OU

NTY

, MIC

HIG

AN

WA

STEW

ATE

R T

REA

TMEN

T SY

STEM

202

0 IM

PRO

VEM

ENTS

MAY 2020

840680

2960 Lucerne Drive SE

P: 616.977.1000F: 616.977.1005

Grand Rapids, MI 49546

DESIG

N. BU

ILD. O

PERA

TE.

PROJ MNGR:DESIGNED BY:

DRAWN BY:

277

Crah

en A

venu

e N

E - G

rand

Rap

ids,

MI 4

9525

Tele

phon

e: (6

16) 4

56-5

227

/ F

ax: (

616)

456

-522

8 /

Web

: ww

w.c

entu

ryae

.com

ENTURY

Faci

litie

s Des

ign

CAE&

ISSU

ED F

OR

100

% R

EVIE

W4/

29/2

020

1M

V

ISSU

ED F

OR

BID

S5/

27/2

020

2M

V

AD

DEN

DU

M N

O. 1

6/19

/202

03

MV

AD

DEN

DU

M N

O. 2

6/25

/202

04

MV

E2.0 062420 jjones

MAINT

ENAN

CE AN

D EQU

IPMEN

T STO

RAGE

BUILD

ING LI

GHTIN

G PL

ANS

E3.1

CCNTLMJZJ

GENERAL NOTES:1. ENGRAVED NAMEPLATES (WHITE PHENOLIC WITH BLACK LETTERS) SHALL BE FURNISHED AND INSTALLED BY

THE ELECTRICAL CONTRACTOR FOR ELECTRICAL EQUIPMENT. LETTER SIZES: 3/16" FOR INDIVIDUALEQUIPMENT.

2. EMERGENCY EXIT SIGNS SHALL BE WIRED TO NON-SWITCHED SIDE OF LOCAL LIGHTING CIRCUIT( AND TOBUILDING LIGHTING INVERTER FOR UNITS WITHOUT BATTERY PACKS.)

3. 120VAC POWER CIRCUITS TO 1Ø, 15A OR 20A LOADS SHALL BE 2#12, 1#12GND IN METAL CONDUIT MINIMUM,AND SIZED PER THE NATIONAL ELECTRIC CODE.

4. ALL CONTROL WIRING BETWEEN LOW VOLTAGE LIGHTING CONTROL DEVICES(I.E. PHOTOCELLS, OCCUPANCYSENSORS, SWITCHES, POWER PACKS, 924 LOAD CONTROL DEVICES, NETWORK BRIDGES, ETC.) SHALL BECAT-6 IN 3/4" METAL CONDUIT. PROVIDE INTERFACE MODULES AS REQUIRED.

5. PROVIDE 2#12,(POWER), 2#14(DIMMING), #12 GND - 3/4"C FROM LOCAL POWER PACK (FOR NON-EMERGENCYFIXTURES) OR 924 DEVICE (FOR EMERGENCY FIXTURES) TO ALL LUMINIARES THAT REQUIRE DIMMINGCONTROLS PER SPECIFICATIONS SECTION 26 09 23 LIGHTING CONTROLS.

PLAN NOTES: (SYMBOL DENOTES PLAN NOTE)

1. WALL MOUNT LUMINAIRE 4'-0" AFF.2. CHAIN HANG LUMINAIRE 12' AFF.3. PROVIDE 120V, 0-10V DIMMING WALL SWITCH, SENSORSWITCH MODEL#sPODMRD, OR EQUAL

WITH WEATHERPROOF STAINESS STEEL COVER WITH BUBBLE , LEGRAND MODEL#4516, OREQUAL.

4. WASH BAY IS A WET LOCATION. PROVIDE PVC COATED CONDUIT AND WET LOCATION FITTINGS.ELECTRICAL RACEWAY AND JUNCTION BOXES IN SPACE TO BE WATERTIGHT AND CORROSIONRESISTANT.

#

1 1

11 3

4

2

Page 6: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

E6.0 062420 jjones

ELEC

TRIC

AL

SIN

GLE

-LIN

E D

IAG

RA

M

E6.0

CCNJZJJZJ

F&V PROJECT NO.

DESIGNTEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

ALL

END

ALE

CH

AR

TER

TO

WN

SHIP

OTT

AW

A C

OU

NTY

, MIC

HIG

AN

WA

STEW

ATE

R T

REA

TMEN

T SY

STEM

202

0 IM

PRO

VEM

ENTS

MAY 2020

840680

2960 Lucerne Drive SE

P: 616.977.1000F: 616.977.1005

Grand Rapids, MI 49546

DESIG

N. BU

ILD. O

PERA

TE.

PROJ MNGR:DESIGNED BY:

DRAWN BY:

277

Crah

en A

venu

e N

E - G

rand

Rap

ids,

MI 4

9525

Tele

phon

e: (6

16) 4

56-5

227

/ F

ax: (

616)

456

-522

8 /

Web

: ww

w.c

entu

ryae

.com

ENTURY

Faci

litie

s Des

ign

CAE&

ISSU

ED F

OR

100

% R

EVIE

W4/

29/2

020

1M

V

ISSU

ED F

OR

BID

S5/

27/2

020

2M

V

AD

DEN

DU

M N

O. 1

6/19

/202

03

MV

Page 7: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

F&V PROJECT NO.

DESIGNTEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

ALL

END

ALE

CH

AR

TER

TO

WN

SHIP

OTT

AW

A C

OU

NTY

, MIC

HIG

AN

WA

STEW

ATE

R T

REA

TMEN

T SY

STEM

202

0 IM

PRO

VEM

ENTS

MAY 2020

840680

2960 Lucerne Drive SE

P: 616.977.1000F: 616.977.1005

Grand Rapids, MI 49546

DESIG

N. BU

ILD. O

PERA

TE.

PROJ MNGR:DESIGNED BY:

DRAWN BY:

277

Crah

en A

venu

e N

E - G

rand

Rap

ids,

MI 4

9525

Tele

phon

e: (6

16) 4

56-5

227

/ F

ax: (

616)

456

-522

8 /

Web

: ww

w.c

entu

ryae

.com

ENTURY

Faci

litie

s Des

ign

CAE&

ISSU

ED F

OR

100

% R

EVIE

W4/

29/2

020

1M

V

ISSU

ED F

OR

BID

S5/

27/2

020

2M

V

AD

DEN

DU

M N

O. 1

6/19

/202

03

MV

E8.0 Details 062420 jjones

ELEC

TRIC

AL

DET

AIL

S

E8.1

CCNJZJJZJ

Page 8: ADDENDUM No. 2 NOTICE TO ALL PROSPECTIVE BIDDERS...2020/06/26  · C A E & ISSUED FOR 100% REVIEW 4/29/2020 1 MV ISSUED FOR BIDS 5/27/2020 2 MV ADDENDUM NO. 1 6/19/2020 3 MV E8.0 Details

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

AL

LE

ND

AL

E C

HA

RT

ER

T

OW

NS

HIP

OT

TA

WA

C

OU

NT

Y, M

IC

HIG

AN

WA

ST

EW

AT

ER

T

RE

AT

ME

NT

S

YS

TE

M 2020 IM

PR

OV

EM

EN

TS

MAY 2020

840680

2960 Lucerne Drive SE

P: 616.977.1000

F: 616.977.1005

Grand Rapids, MI 49546

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

277

Cra

hen

Ave

nue

NE

- Gra

nd R

apid

s, M

I 495

25Te

leph

one:

(616

) 456

-522

7 /

Fax

: (61

6) 4

56-5

228

/ W

eb: w

ww

.cen

tury

ae.c

om

ENTURY

Faci

litie

s D

esig

nC

AE

&

IS

SU

ED

F

OR

1

00

% R

EV

IE

W4

/2

9/2

02

01

MV

IS

SU

ED

F

OR

B

ID

S5

/2

7/2

02

02

MV

AD

DE

ND

UM

N

O. 1

6/1

9/2

02

03

MV

AD

DE

ND

UM

N

O. 2

6/2

5/2

02

04

MV

E9.0 System Riser Diagrams

062620 tmcdonald

FIR

E A

LA

RM

, S

UR

VE

IL

LA

NC

E, A

ND

C

OU

NT

Y N

ET

WO

RK

R

IS

ER

D

IA

GR

AM

S

E9.2

CCN

JZJ

JZJ