dnhiggins.comdnhiggins.com/docs/leri addendum 1 plans 3.pdf · the following symbols may be used...
TRANSCRIPT
![Page 1: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/1.jpg)
![Page 2: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/2.jpg)
![Page 3: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/3.jpg)
![Page 4: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/4.jpg)
THE FOLLOWING SYMBOLS MAY BE USED THROUGHOUT DRAWINGS TO REFER TO OTHER VIEWS:
A
S1.03
A
S1.03
A
S1.03
STRUCTURAL SYMBOLS AND NOTATIONS
DRAWING INTERPRETATION MATERIAL IDENTIFICATION SYMBOLS
A. DRAWING VIEWS LABELED AS "TYPICAL"
1. PARTIAL PLANS, ELEVATIONS, SECTIONS, DETAILS, OR SCHEDULES LABELED WITH "TYPICAL" AT BEGINNING OF THEIR TITLE APPLY TO SITUATIONS OCCURING ON PROJECT THAT ARE SAME OR SIMILAR TO THOSE INDICATED. APPLICABILITY OF CONTENT OF THESE VIEWS TO LOCATIONS ON PLAN CAN BE DETERMINED FROM TITLE OF VIEWS. SUCH VIEWS APPLY WHETHER OR NOT THEY ARE KEYED IN AT EACH LOCATION.
B. STRUCTURAL ABBREVIATIONS1. THE FOLLOWING ABBREVIATIONS MAY BE USED IN THE STRUCTURAL DRAWINGS:@ AT& AND# NUMBER
ROUND, DIAMETERSQUARE, TUBE
A-ANC ADHESIVE ANCHORADDL ADDITIONALAESS ARCHITECTURAL EXPOSED
STRUCTURAL STEELANC ANCHORAHU AIR HANDLING UNITALT ALTERNATEAPPRX APPROXIMATEAR ANCHOR RODARCH ARCHITECTURALBF BRACED FRAMEBLDG BUILDINGBM BEAMB/ BOTTOM OFB BOTTOMBPL BENT PLATEBRDG BRIDGINGBRG BEARINGBTWN BETWEENC CAMBER, COMPRESSIONCANT CANTILEVERCFMF COLD-FORMED METAL FRAMINGCIP CAST-IN-PLACECJ CONSTRUCTION/ CONTROL JOINTCJP COMPLETE JOINT PENETRATIONCL CENTERLINECLR CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONN CONNECTIONCONSTR CONSTRUCTIONCONT CONTINUOUSCOORD COORDINATECVR COVERCPRS COMPRESSIBLECTR (S ) CENTER (S )
D DEPTHdb BAR DIAMETERDBA DEFORMED BAR ANCHORDCW DEMAND CRITICAL WELDDET DETAILDIA DIAMETERDIM DIMENSIONDWG (S ) DRAWING (S )
DWL DOWELE ECCENTRICITYEA EACHEF EACH FACEEJ EXPANSION JOINTEL ELEVATIONELEV ELEVATOREMBED EMBEDMENT, EMBEDDEDENG ENGINEEREQ EQUALEQUIP EQUIPMENTEQUIV EQUIVALENTES EACH SIDEEW EACH WAYEXIST EXISTINGEXP EXPANSIONEXT EXTERIORFAB FABRICATEf'c= 28 DAY CONCRETE STRENGTH=f'm= 28 DAY MASONRY STRENGTH=FD FLOOR DRAINFDN FOUNDATIONFF FAR FACEFIN FINISHFLR FLOORFS FAR SIDEFTG FOOTINGFUT FUTUREFV FIELD VERIFYFy= YIELD STRENGTH=GALV GALVANIZE (D )
GEN GENERALGR GRADEH HORIZONTALHCA HEADED CONCRETE ANCHORHGR HANGERHI HIGHHSS HOLLOW STRUCTURAL SECTIONID INSIDE DIAMETER
LLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLO LOWLONG LONGITUDINALLSH LONG SIDE HORIZONTALLSLP LONG-SLOTTED HOLE PARALLELLSLT LONG-SLOTTED HOLE TRANSVERSELSV LONG SIDE VERTICALLWC LIGHTWEIGHT CONCRETEM MOMENTM-ANC MECHANICAL ANCHORMAS MASONRYMAX MAXIMUMMC MOMENT CONNECTIONMECH MECHANICALMEZZ MEZZANINEMFR MANUFACTURERMH HORIZONTAL MOMENTMIN MINIMUMMISC MISCELLANEOUSMTL METALMU MECHANICAL UNITNF NEAR FACENIC NOT IN CONTRACTNS NEAR SIDENTS NOT TO SCALENWC NORMALWEIGHT CONCRETEOC ON CENTEROD OUTSIDE DIAMETEROPH OPPOSITE HANDOPNG OPENINGOPP OPPOSITEOVS OVERSIZED HOLEP AXIAL LOADPAF POWDER ACTUATED FASTENERPAR PARALLELPCC PRECAST CONCRETEPCF POUNDS PER CUBIC FOOTPCY POUNDS PER CUBIC YARDPERP PERPENDICULARPL PLATEPLF POUNDS PER LINEAR FOOTPLUMB PLUMBINGPJP PARTIAL JOINT PENETRATIONPRELIM PRELIMINARYPROP PROPERTYPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT POST-TENSION (ED )
QTY QUANTITYR REACTIONRAD RADIUSREF REFERENCEREINF REINFORCEMENTREM REMAINDERREQD REQUIREDREQMT (S ) REQUIREMENT (S )
REV REVISIONRH HORIZONTAL REACTIONRS ROCK SOCKETRTU ROOF TOP UNITSC SLIP-CRITICAL, SHEAR CONNECTORSCHED SCHEDULE (D )
SDS SELF-DRILLING SCREWSECT SECTIONSHT SHEETSIM SIMILARSLBB SHORT LEG BACK TO BACKSLRS SEISMIC LOAD RESISTING SYSTEMSOG SLAB-ON-GRADESPA SPACINGSPEC SPECIFICATIONSPL SPLICESUP SUPPORTSQ SQUARESS STAINLESS STEELSSLP SHORT-SLOTTED HOLE PARALLELSSLT SHORT-SLOTTED HOLE TRANSVERSESTD STANDARDSTIF STIFFENERSTIR STIRRUPSTL STEELSTRUCT STRUCTURE, STRUCTURALSW SHEAR WALLSYM SYMMETRIC, SYMMETRICALT TENSION, TOPT/ TOP OFTHD THREADEDTHRU THROUGH
THE FOLLOWING MATERIAL IDENTIFICATION SYMBOLS MAY BE USED:
CAST-IN-PLACECONCRETE
EARTH GRAVEL GROUT
CMU STEEL
GRATING
SYMBOLIC LINEWORK
THE FOLLOWING SYMBOLIC LINEWORK MAY BE USED:
REFERENCE GRID LINE
CENTERLINE
PLAN MATCHLINE
WELDED WIRE REINFORCEMENT
VIEW REFERENCE SYMBOLS
HIDDEN LINE
SECTIONIDENTIFICATION LETTER
DRAWING WHERESECTION IS SHOWN
SECTIONIDENTIFICATION LETTER
DRAWING WHERESECTION IS SHOWN
N REF
SECTIONIDENTIFICATION LETTER
DRAWING WHERESECTION IS SHOWN
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PR
OFE
SS
I O N A LE
NG
IN
EE
R
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
ISOMETRIC
SCALE: 3/32" = 1'=0"
1
S-O
ISOMETRIC
SCALE: 3/32" = 1'=0"
2
S-O
GENERAL NOTESS-0
![Page 5: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/5.jpg)
ALL WORK TO BE PERFORMED UNDER THIS CONTRACT SHALL
COMPLY WITH THE MOST RECENT EDITION OF THE FLORIDA
BUILDING CODE, CITY LABOR LAWS, CITY ORDINANCES, CITY/
COUNTY ZONING CODES, RULES AND REGULATIONS, AND
ANY APPLICABLE CODES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR OBTAINING ALL REQ'D PERMITS TO CARRY
OUT THE WORK DESCRIBED IN THE CONSTRUCTION
DOCUMENTS.
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION
WITH PROJECT SPECIFICATIONS, ARCHITECTURAL,
MECHANICAL, ELECTRICAL, PLUMBING, CIVIL AND SITE
DRAWINGS. CONSULT THESE DOCUMENTS FOR SLEEVES,
DEPRESSIONS AND ANY OTHER DETAIL NOT SHOWN ON THE
STRUCTURAL DOCUMENTS.
ALL DIMENSIONS AND CONDITIONS MUST BE VERIFY IN THE
FIELD. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER OF RECORD BEFORE
PROCEEDING WITH THE AFFECTED PART OF THE WORK.
CONTRACTOR(S) SHALL FAMILIARIZE HERSELF/ HIMSELF
WITH ALL THE EXISTING CONDITIONS
AT THE SITE RELATIVE TO SCOPE OF WORK RELATING TO
THIS PROJECT, MATERIALS HANDLING, STORAGE AND
DELIVERY, WORKING SPACE AVAILABLE, SAFETY
PRECAUTIONS REQUIRED, AND ALL OTHER CONDITIONS
NECESSARY TO THE MAKING OF AN ACCURATE AND
COMPLETE PROJECT BID, NO INCREASE IN PROJECT COST
WILL BE ALLOWED FOR FAILURE OF THE CONTRACTOR TO
KNOW EXISTING SITE CONDITIONS.
THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND
STABLE AFTER THE BUILDING IS COMPLETED. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION
PROCEDURES AND SEQUENCING TO ENSURE SAFETY OF THE
BUILDING AND ITS COMPONENTS DURING ERECTION. THIS
INCLUDES THE ADDITION OF NECESSARY SHORING,
SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS.
DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ANY
DIMENSIONS NOT INDICATED ON DRAWINGS SHALL BE
CONFIRMED WITH ENGINEER PRIOR TO CONSTRUCTION.
NO WORK SHALL BE PERFORMED OUTSIDE THE PROJECT
LIMITS WITHOUT PRIOR WRITTEN APPROVAL FROM THE
BUILDING OWNER AND OR ENGINEER.
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING
THE WORK OF ALL TRADES AS REQUIRED FOR COMPLETION
OF WORK.
MATERIALS SHALL BE NEW, OF QUALITY SPECIFIED,
DELIVERED IN A TIMELY FASHION AND AMPLE QUANTITY TO
PREVENT DELAY OF WORK. SUBSTITUTIONS REQUIRE PRIOR
APPROVAL FROM ENGINEER.
THERE ARE NO SUBSTITUTIONS ALLOWED UNLESS
APPROVED BY THE ENGINEER. THE G. C. SHALL SUBMIT IN
WRITING ALL REQUESTS FOR SUBSTITUTIONS.
THE G. C. SHALL SUBMIT IN WRITING TO THE ENGINEER
PRIOR INSTALLATION, IF ANY UNFORESEEN CONDITIONS
AFFECTING INSTALLATION ACCORDING TO SPECIFICATIONS.
ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE
TYPICAL CONDITIONS UNLESS DETAILED OR NOTED
OTHERWISE.
CODES AND STANDARDS
THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE
FOLLOWING CODES:
A FLORIDA BUILDING CODE / 2010 EDITION & 2011
SUPPLEMENT
B BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE (ACI 318-02).
C MANUAL OF STANDARD PRACTICE FOR DETAILING
REINFORCED CONCRETE STRUCTURES (ACI 315 /
LATEST EDITION)
D MANUAL FOR STANDARD PRACTICE FOR WELDING
REINFORCED STEEL INSERTS & CONNECTIONS IN
REINFORCED CONCRETE CONSTRUCTION AWS. D1.4 /
LATEST EDITION.
E SPECIFICATION FOR THE DESIGN. FABRICATION &
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS.
(AMERICAN INSTITUTE OF STEEL CONSTRUCTION) ASIC
ASD / 9TH EDITION.
ALL CHANGES AND ADDITIONS MADE ON RE-SUBMITTAL MUST
BE CLEARLY FLAGGED AND NOTED THE PURPOSE OF THE
RE-SUBMITTAL MUST BE CLEARLY NOTED ON THE LETTER OF
TRANSMITTAL. ARCHITECT/ENGINEER REVIEW WILL BE
LIMITED TO THOSE ITEMS CAUSING THE RE-SUBMITTAL.
SHOP DRAWINGS REQUIRED ENGINEERING INPUT BY
SPECIALTY ENGINEER
SUBMITTAL SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT
AND APPLICABLE CODES, LIST DESIGN CRITERIA, AND SHOW
ALL DETAILS AND PLANS NECESSARY FOR PROPER
FABRICATION AND INSTALLATION CALCULATIONS AND SHOP
DRAWINGS SHALL IDENTIFY SPECIFIC PRODUCT UTILIZED.
GENERIC PRODUCT WILL NOT BE ACCEPTED.
SHOP DRAWING AND CALCULATIONS MUST BE PREPARED
UNDER THE DIRECT SUPERVISION AND CONTROL OF THE
SPECIALTY ENGINEER.
SHOP DRAWINGS AND CALCULATIONS REQUIRE THE
IMPRESSED SEAL, DATE AND SIGNATURE OF THE SPECIALTY
ENGINEER. COMPUTER PRINTOUTS ARE AN ACCEPTABLE
SUBSTITUTE FOR MANUAL COMPUTATIONS PROVIDED THEY
ARE ACCOMPANIED BY SUFFICIENT DESCRIPTIVE
INFORMATION TO PERMIT THEIR PROPER EVALUATION, SUCH
DESCRIPTIVE INFORMATION SHALL BEAR THE IMPRESSED
SEAL AND SIGNATURE OF THE SPECIALTY ENGINEER AS AN
INDICATION THAT HE/SHE HAS ACCEPTED RESPONSIBILITY
FOR THE RESULT.
DRAWINGS PREPARED SOLELY TO SERVE AS A GUIDE FOR
FABRICATION AND INSTALLATION, (SUCH AS REINFORCING
STEEL SHOP DRAWINGS OR STRUCTURAL STEEL ERECTION
DRAWINGS), AND REQUIRING NO ENGINEERING INPUT DO
NOT REQUIRE THE SEAL OF A SPECIALTY ENGINEER.
REVIEW BY THE STRUCTURAL ENGINEER OF RECORD OF
SUBMITTAL IS LIMITED TO VERIFY THE FOLLOWING:
• THAT THE SPECIFIED STRUCTURAL SUBMITTALHAVE BEEN FURNISHED.
• THAT THE STRUCTURAL SUBMITTAL HAVE BEENSIGNED AND SEALED BY THE SPECIALTY ENGINEER.
•THAT THE SPECIALTY ENGINEER HAS
UNDERSTOOD THE DESIGN INTENT AS HAS USED
THE SPECIFIED STRUCTURAL CRITERIA. (NO DETAIL
CHECK OF DIMENSIONS OR QUANTITIES WILL BE
MADE.)
•THAT THE CONFIGURATION SET FORTH IN THE
STRUCTURAL SUBMITTAL IS CONSISTENT WITH THE
CONTRACT DOCUMENTS. (NO DETAIL CHECK OF
DIMENSIONS OR QUANTITIES WILL BE MADE).
SUBMITTAL NOT MEETING THE ABOVE REFERENCED
CRITERIA WILL NOT BE REVIEWED
FORMWORK AND SHORING (CONCRETE SLABS AND BEAMS)
NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS
REACHED AT LEAST TWO THIRDS OF THE 28 DAY DESIGN
STRENGTH. A MINIMUM OF 3 STORIES OF SHORING AND (/OR)
RE-SHORING SHALL BE USED WHICH SHALL CONSIST OF ONE
COMPLETE SET OF VERTICAL SHORES AND TWO SETS OF
VERTICALS SHORES THAT COMPROMISE AT LEAST 50% OF A
COMPLETE SET.
DESIGN, ERECTION AND REMOVAL OF ALL FORMWORK,
SHORES AND RE-SHORES SHALL MEET REQUIREMENTS SET
FORTH IN ACI STANDARDS 347 AND 301.
DRAWINGS FOR SHORING AND RE-SHORING SHALL BE
PREPARED BY A FLORIDA REGISTERED PROFESSIONAL
ENGINEER.
PLUMBING SLEEVES
MINIMUM SLEEVE SPACING SHALL BE THREE DIAMETERS
CENTER TO CENTER OF LARGER SLEEVE OR 6" CLEAR
BETWEEN SLEEVES, WHICHEVER IS GREATER. PRIOR TO
CONSTRUCTION, SLEEVE LOCATIONS AND SIZES SHALL BE
APPROVED BY THE ENGINEER OF RECORD.
REINFORCING STEEL
SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE
FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE
WITH THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS
OF ACI STANDARDS AND SPECIFICATIONS. SECURE
APPROVAL OF SHOP DRAWINGS PRIOR COMMENCING ANY
FABRICATION.
F SPECIFICATION FOR STRUCTURAL CONCRETE FOR
BUILDINGS. ACI 301 / LATEST EDITION.
G BUILDING CODE REQUIREMENTS AND SPECIFICATIONS
FOR MASONRY STRUCTURES (ACI 530-05 & ACI 530.1-05).
DESIGN CRITERIA
ALL WORK SHALL CONFORM WITH THE MINIMUM STANDARDS
AS SPECIFIED IN THE FLORIDA BUILDING CODE LATEST
EDITION AND ASCE 7-10.
LOAD COMBINATION AS PER ASCE 7-10
ASD
1 D + (L OR LR)
2 D + 0.75L + 0.75LR
3 D + 0.6(WP OR WS)
4 D + 0.75L + 0.75LR + 0.75(0.6WP OR 0.6WS)
LRFD
1 1.2D + 1.6L + 0.5LR
2 1.2D + 1.6LR + 1.0L
3 1.2D + 1.6 LR + 0.5(WP OR WS)
4 1.2D + (WP OR WS) + L = 0.5LR
5 0.9D + 1.0(WP OR WS)
MISC. STRUCTURAL STEEL 36,000 PSI
REINFORCEMENT - STEEL 60,000 PSI
CONCRETE
MINIMUM 28 STRENGTH 3,000 PSI
EXCEPT AS FOLLOWS U.N.O.
ROOF DECK 4,000 PSI
BEAM 4,000 PSI
COLUMN 4,000 PSI
WALL 4,000 PSI
FOUNDATION 4,000 PSI
SOIL BEARING AS PER GEOTECHNICAL REPORT
COMPONENTS AND CLADDING DESIGN
ALL EXTERIOR WALLS, ROOFING COMPONENTS AND CLADDING
SHALL BE DESIGNED FOR THE SPECIFIED WIND PRESSURES
SHOWN HERE WITH THESE DOCUMENTS, OR HAVE A
PRODUCT APPROVAL FOR THE APPLICABLE WIND
PRESSURES.
THE WIND PRESSURES LISTED IN THE DRAWINGS HAVE BEEN
OBTAINED FROM A WIND TUNNEL PROCEDURE I
ACCORDANCE WITH SECTION 6.4.3 OF ASCE 7-10.
THRESHOLD INSPECTION
THE OWNER SHALL EMPLOY A QUALIFIED SPECIAL
INSPECTOR TO PERFORM INSPECTIONS IN ACCORDANCE
WITH THE "THRESHOLD INSPECTION GUIDELINES", ISSUED
SEPARATELY BY THE ARCHITECT OR ENGINEER OF RECORD.
THE SPECIAL INSPECTOR SHALL CERTIFY WITH HIS SEAL AND
SIGNATURE AT THE END OF CONSTRUCTION, THAT THE
CONSTRUCTION OF THIS STRUCTURE HAS BEEN COMPLETED
ACCORDING TO THE PROJECT PLANS AND SPECIFICATIONS.
SPECIAL INSPECTIONS SHALL BE PERFORMED BY A
REGISTERED PROFESSIONAL ENGINEER LICENSED TO
PERFORM INSPECTIONS UNDER FLORIDA THRESHOLD LAW
OR HIS QUALIFIED FULL TIME EMPLOYEE.
SHOP DRAWING REVIEW
SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL
COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT
DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT
DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS,
DIMENSIONS, ETC.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE
CONTRACTOR PRIOR TO SUBMITTAL TO THE
ARCHITECT/ENGINEER. DRAWINGS SUBMITTED WITHOUT
REVIEW WILL BE RETURNED UNCHECKED.
IN ALL INSTANCES THE CONTRACT DOCUMENTS WILL
GOVERN OVER THE SHOP DRAWINGS UNLESS OTHERWISE
SPECIFIED IN WRITING BY THE ENGINEER OF RECORD.
REPRODUCTION OF STRUCTURAL DRAWINGS FOR USE AS
SHOP DRAWINGS IS NOT PERMITTED.
WELDED WIRE FABRIC
TO CONFORM TO ASTM A-185, FREE FROM OIL, SCALE AND
RUST AND PLACE IN ACCORDANCE WITH THE TYPICAL
PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS.
MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES.
EMBEDDED ITEMS IN CONCRETE
EMBEDDED ITEMS INCLUDING BUT NOT LIMITED TO STEEL
PLATES FOR CONNECTIONS, WATER STOPS, DOVETAIL SLOTS
FOR MASONRY ANCHORS, INSERTS FOR GLASS DOOR AND
RAILS, DOWNSPOUT PIPES IN COLUMNS SHALL BE
COORDINATED BY THE CONTRACTOR IN A TIMELY MANNER.
ALL EMBEDDED STEEL PLATES FOR THE CONNECTION OF
WALL FRAMING, ROOF FRAMING AND MISCELLANEOUS STEEL
SHALL BE COORDINATED WITH WALL PANEL JOINTS AND
OPENINGS. SUBMIT SHOP DRAWINGS AND OBTAIN ENGINEER
APPROVAL PRIOR CONCRETE PLACEMENT.
CONCRETE
SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO
ACHIEVE A STRENGTH AT 28 DAYS AS LISTED BELOW WITH A
PLASTIC AND WORKABLE MIX:
4,000 PSI FOR COLUMN: WATER TO CEMENT RATIO BY
WEIGHT SHALL NOT EXCEED 0.50
3,000 PSI FOR FOUNDATION AND SLABS ON GRADE; WATER
TO CEMENT RATIO BY WEIGHT SHALL NOT EXCEED 0.60.
4,000 PSI FOR BEAM: WATER TO CEMENT RATIO BY WEIGHT
SHALL NOT EXCEED 0.50
4,000 PSI FOR ALL OTHER STRUCTURAL CONCRETE; WATER
TO CEMENT RATIO BY WEIGHT SHALL NOT EXCEED 0.50
CONCRETE SHALL BE PLACED AND CURED ACCORDING TO
ACI STANDARDS AND SPECIFICATIONS.
SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD
CYLINDERS OR LAB TEST FOR REVIEW PRIOR TO USE. MIX
SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER
POSITIVE IDENTIFICATION. MIX SHALL MEET THE
REQUIREMENTS OF ASTM C33 FOR COARSE AGGREGATE.
CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF
ASTM STANDARDS C94 FOR MEASURING, MIXING,
TRANSPORTING, ETC.
CONCRETE TICKETS SHALL BE TIME STAMPED WITH
CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM
THE TIME THE MIXING WATER IS ADDED UNTIL IT IS
DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ON
AND ONE HALF, (1 1/2), HOURS. IF FOR ANY REASON THERE IS
A LONGER DELAY THAN THAT STATED ABOVE, THE
CONCRETE3 SHALL BE DISCARDED, IT SHALL BE THE
RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE
OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY
NONCOMPLIANCE THE ABOVE.
ALL SLABS SHALL BE CURED USING A DISSIPATING CURING
COMPOUND MEETING ASTM STANDARD C309 TYPE 1 AND
SHALL HAVE A FUGITIVE DYE. THE COMPOUND SHALL BE
PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS
SOON AS THE WATER HAS LEFT THE UNFINISHED CONCRETE
ALL SCUFFED OR BROKEN AREAS IN THE CURING MEMBRANE
SHALL BE RECOATED DAILY.
ALL CONCRETE SHALL HAVE MID-RANGE WATER REDUCING
ADMIXTURE CONFORMING TO ASTM C494 TYPE A.
ADMIXTURES CONTAINING CHLORIDE IONS MORE THAN 0.05
PERCENT BY WEIGHT IN THE ADMIXTURE SHALL NOT BE
USED. OTHERS ADMIXTURES SHALL BE APPROVED BY THE
ENGINEER OF RECORD. AIR-ENTRAINING ADMIXTURES SHALL
NOT BE USED IN STRUCTURAL CONCRETE.
ALL CONCRETE MIX DESIGN DESIGNS SHALL INCLUDE A
WRITTEN DESCRIPTION INDICATING WHERE EACH
PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE.
ALL CONCRETE DESIGN MIX SUBMITTAL SHALL INCLUDE
TESTED, STATISTICAL BACK-UP DATA AS PER CHAPTER 5 OF
ACI 318.
CONCRETE TESTING
AN INDEPENDENT TESTING LABORATORY SHALL PERFORM
THE FOLLOWING TEST ON CAST IN PLACE CONCRETE;
ASTM C143 - "STANDARD TEST METHOD FOR SLUMP OF
PORTLAND CEMENT CONCRETE". MAXIMUM SLUMP SHALL BE
4" INCHES. CONCRETE CONTAINING MID-RANGE WATER
REDUCED SHALL HAVE A MAXIMUM SLUMP OF 7.5 INCHES.
ASTM C39 - " STANDARD TEST METHOD FOR COMPRESSIVE
STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS." A
SEPARATE TEST SHALL BE CONDUCTED FOR EACH CLASS,
FOR EVERY 50 CUBIC YARDS, OR FRACTION THEREOF,
PLACED PER DAY. REQUIRED CYLINDERS QUANTITIES AND
TEST AGE AS FOLLOWS:
• 1 AT 7 DAYS
• 2 AT 28 DAYS
ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER
THE DIRECTION OF THE ENGINEER, IF REQUIRED, IF 28 DAY
STRENGTH IS ACHEIVED, THE CYLINDER MAY BE DISCARDED.
PENETRATION
NO PENETRATING SHALL BE MADE IN ANY STRUCTURAL
MEMBERS OTHER THAN THOSE LOCATED ON THESE
DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE
ENGINEER.
CHEMICAL ANCHORS.
SHALL BE TWO PART EPOXY POLYMER INJECTION SYSTEM,
SUCH AS RAMSET 'EPCON", RAWL "FOIL-FAST" CARTRIDGE
SYSTEM, DUR-O-WALL, "DUR-O-PAIR" EPOXY ANCHOR, OR
HILTI HSE2411 EPOXY DOWELING SYSTEM, OR APPROVED
EQUAL. INSTALL IN ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS. INSTALLERS SHALL BE TRAINED BY THE
MANUFACTURER'S REPRESENTATIVE.
WELDING
WELDING SHALL BE DONE BY A CERTIFIED WELDERS USING
ASTM E70XX SERIES FOR SHOP WELDING A36 STEEL, AND
E70XX SERIES LOW HYDROGEN ELECTRODES FOR ALL
WELDING OF HIGH STRENGTH STEELS AND FOR ALL FIELD
WELDING.
WELDS SHOWN ON STRUCTURAL DRAWINGS ARE MINIMUM
DESIGN REQUIREMENTS. THE FABRICATOR'S SHOP SHALL
REFLECT WELDS IN ACCORDANCE WITH AWS REQUIREMENTS.
FULL PENETRATION GROOVE WELDS SHALL BE INSPECTED BY
ULTRASONIC TESTING. TWENTY-FIVE PERCENT OF THE
WELDS SHALL BE INSPECTED AT RANDOM UNLESS NOTED
OTHERWISE, SEE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS. IF NON- COMPLIANCE IS FOUND, ADDITIONAL
TEST MAY BE ORDERED BY THE ENGINEER AT THE EXPENSE
OF THE CONTRACTOR.
WHEN WELDS ARE NOT CALLED OUT ON DRAWINGS, THEY
ARE MINIMUM SIZE CONTINUOUS FILLET WELDS IN
ACCORDANCE WITH AWS D1.1. FILLET WELDS NOT SPECIFIED
AS TO LENGTH SHALL BE CONTINUOUS.
UNLESS NOTED OTHERWISE ON THE DRAWINGS ALL GROOVE
WELDS SHALL BE FULL PENETRATION.
PROVIDE FILLET WELDS AT ALL CONTACT JOINT BETWEEN
STEEL MEMBERS SUFFICIENT TO DEVELOP THE ALLOWABLE
TENSILE STRENGTH OF THE SMALLER MEMBER
AT THE JOINT UNLESS DETAILED OTHERWISE.
NET UPLIFT DESIGN
STEEL ROOF JOIST SHALL BE DESIGNED TO WITHSTAND THE
UPLIFT DUE TO WIND, SHOWN IN THE WIND LOAD UPLIFT
DIAGRAM. IN ADDITION TO THE STANDARD SJI BOTTOM
CHORD BRIDGING, WHICH INCLUDES THE FIRST END PANELS
THE JOIST MANUFACTURER SHALL PROVIDE DESIGN
CALCULATIONS FOR UPLIFT, EITHER CONFORMING THE SJI
BRIDGING REQUIREMENTS OR PROVIDING A DESIGN
ADEQUATE FOR UPLIFT. THIS SUBMITTAL SHALL BEAR THE
SIGNATURE AND IMPRESSED SEAL OF A FLORIDA
REGISTERED ENGINEER.
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PR
OF
E
SS
I O N A LE
NG
IN
EE
R
ST
AT
EO F F L O
RI
DA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
GENERAL NOTESS-01
![Page 6: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/6.jpg)
11
22
33
44
55
66
77
B
B
C
C
D
D
22' - 5" 7' - 3"
81' - 2"
9' - 2"
9' - 2"
9' - 2"
9' - 2"
20' - 6"
19' - 6"
9' - 2"
9' - 2"
9' - 2"
20' - 6"
19' - 6"
9' - 2"
#5 @ 8" O.C. E.W. (TOP &BOTTOM)
EL. - 8.5'
24" CONCRETE SLAB
1
S.3
2
S.3
1
S.4
2
S.4
1
S.5
#5@ 8" O.C. E.W. (TOP &BOTTOM)
7' - 6"
86' - 8"
22' - 5" 7' - 3"
38' - 6"
A
A
4.68°
4.68°
42' - 8"
27' - 5"
42' - 8"
0' - 0"
13' - 0"
T.O.S.
54"X52" WIDE, CONCRETEBEAM W/ (14) #6 CONT.AND # 3 STIRRUPS @ 8"O.C.
4' - 0"
6' - 0"
2' - 6"
6"
TE-1
TE-1
TE-1
TE-3
TE-2
1
S.6
2
S.5
11
22
33
44
55
66
77
B
B
C
C
D
D
9' - 2"
9' - 2"
9' - 2"
9' - 2"
20' - 6"
19' - 6"
1
S.3
2
S.31
S.4
2
S.4
1
S.5
6' - 7" 3' - 7"
2
1
2
2
2
2
2
1
5
1
1
11
1
1
7' - 6"
25' - 0"
7' - 6"
#4 - 48" LONG , (TOP)
#4 - 48" LONG , (TOP)
#4 - 48" LONG , (TOP)
EL. -8.5'.
10' - 0" 6' - 6"
22' - 5" 7' - 3"
9' - 2"
9' - 2"
9' - 2"
9' - 2"
20' - 6"
19' - 6"
22' - 5" 7' - 3"
T.O.S
#4 - 48" LONG , (TOP)
#4 - 48" LONG , (TOP)
A
25' - 1"2' - 0"
EDGE OF FOUNDATIONSLAB, REFER TOFOUNDATION PLAN
5
94.68°
4.68°
37' - 10"
40' - 0"
#6 @8" O.C.(T&B)
#6 @8" O.C.
(T&B)
#4 @8" O.C. (TOP)
13' - 2"
24" CONCRETE SLAB
4'-6"6"
EL. -4.0'.T.O.S.
2' - 0"
9' - 10 7/8"
6"
11' - 10 7/8"
6' - 0" 6' - 0" 6' - 1"
5' - 5"
5' - 5"
6' - 1" 6' - 1"
1
S.6
1
S.6
Sim
4
C4 C4 C4
C4C4
C4
15' - 4"
2
S.5
6"
4'-0"
WALL TYPE 3, (BELOW)
EL. -4.0'.T.O.S.
ALL FOUNDATION SLAB SHALL BE 24" CONCRETE WITH # 6 @ 8" ONCENTER, EACH WAY AND EACH FACE, (TOP AND BOTTOM), U.N.O.
FOR REINFORCEMENT GRADE AND TYPE, REFER TO GENERAL NOTESOR SPECIFICATIONS.
SLAB ELEVATION SHALL BE -8.5', UNLESS NOTED OTHERWISE.
FOUNDATION PLAN, NOTES AND SPECIFICATION SHALL READ INCONJUNCTION WITH ALL RELATED DISCIPLINES DOCUMENTS.
REFER TO CIVIL DOCUMENTS FOR LAB LOCATION AND ORIENTATION.
REFER TO GEOTECHNICAL REPORT FOR SOIL BEARING CAPACITY ANDFOUNDATION RECOMMENDATIONS.
FOUNDATION SLAB SHALL BE RESTED ON A 30" DEEP LAYER OF TREMIEGROUT. REFER TO GEOTECHNICAL REPORT, FOR TREMIE GROUTSPECIFICATION AND RECOMMENDATIONS.
ANY DISCREPANCY SHALL BE REPORTED IN WRITING TO ENGINEER OFRECORD, PRIOR COMMENCING ANY WORK.
ALL REINFORCEMENT STEEL SHALL BE PLACED IN ACCORDANCE OF ACI318,AND ANY APPLICABLE CODE.
ID / SYMBOL DESCRIPTION
INDICATES SLAB @ DIFFERENT ELEVATION
. INDICATES TARGET ELEVATION
STEEL INDICATES REINFORCEMENT SIZE AND DIRECTION
INDICATES DIRECTION OF SLAB SPAN
A INDICATES GRIDE LINE ID.
INDICATES WALL TYPE1
INDICATES CENTER LINE
INDICATES STEP DOWN SLAB
ID / SYMBOL DESCRIPTION WALL TYPE DESCRIPTION
1
2
3
4
12" CONCRETE WALL W/ #6 @ 8" O.C. E.W. AND E.F.
12" CONCRETE WALL W/ #6 @ 8" O.C. E.W. AND E.F.
8" CONCRETE WALL W/ #5 @ 8" O.C. E.W. AND E.F.
24" CONCRETE WALL W/ (4 LAYERS #6 @ 8" O.C. E.W.
THICKEN EDGE REINFORCEMENT
(5) #6 (T&B), AND (2) MID AND #5TRANSVERSE @ 8" O.C..
(5) #6 (T&B), AND (2) MID AND #5TRANSVERSE @ 8" O.C..
(5) #6 (T&B), AND (2) MID AND #5TRANSVERSE @ 8" O.C..
TE-1
SIZE
TE-2
TE-3
42"X48"xCONT.
42"X48"xCONT.
42"X48"xCONT.
LEGEND NOTES WALL TYPES SCHEDULE THICKENED EDGE SCHEDULE
14" CONCRETE WALL W/ #6 @ 6" O.C. E.W. AND E.F.5
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LAKD
AS
N A N A YAK
KARA
PROFE
SSI O N A L
ENG
INEER
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
FOUNDATION PLAN
SCALE: 1/8" = 1'=0"0' 4' 8' 16' 32'
1
S-1
FLOOR PLAN - EL. -8.5'
SCALE: 1/8" = 1'=0"0' 4' 8' 16' 32'
2
S-1
S-1FOUNDATION AND LEVEL 1 PLANS-1
![Page 7: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/7.jpg)
11
22
33
44
55
66
77
B
B
C
C
D
D
1
S.3
2
S.3
1
S.4
2
S.4
1
S.5
9' -
2"
9' -
2"
9' -
2"
9' -
2"
20
' - 6
"1
9' -
6"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
22' - 5" 7' - 3"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
PU
MP
MA
NU
FA
CT
UR
ER
VE
RIF
Y W
/
PU
MP
MA
NU
FA
CT
UR
ER
VE
RIF
Y W
/
OPEN TO BELOW
36
' - 8
"4
0' -
0"
22' - 5" 7' - 3"
11' - 0" 6' - 6"7
' - 6
"7
' - 6
"
C1
C1
C1
C3
C2
A
2' - 1
5/8
"
12' - 0"
39
' - 1
1"
15' - 4" 6' - 7" 3' - 7" 4' - 2"
1
2 2
22
2 2
5
1
1
1
PU
MP
MA
NU
F.
VE
RIF
Y W
/
1
1
1
1
1
5
25' - 1" 5' - 5"10' - 0"
6' - 6"
3
3
CONCRETE WALLBELOW
-5' - 0"
T.O.W.
-5' - 0"
T.O.W.
6' - 0
"3' - 0
"6' - 0
"
3' - 2
3/8
"
6' - 0
"
3' - 2
3/8
"
6' - 0
"
1
11
' - 6
"2
' - 0
"1
1' -
6"4
40
' - 0
"
1
S.6
1
S.6
Sim
C4 C4 C4
C4 C4 C4
5
5
2
S.5
11
22
33
44
55
66
77
B
B
C
C
D
D
22' - 5" 7' - 3"
9' -
2"
9' -
2"
9' -
2"
9' -
2"
20
' - 6
"1
9' -
6"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
22' - 5" 7' - 3"
5' - 10" 3' - 8" 9' - 11 5/8" 8' - 9 3/8"
7' -
6"
7' -
6"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
4' -
7"
5' -
1"
9' -
2"
9' -
2"
9' -
2"
9' -
2"
20
' - 6
"1
9' -
6"
1
S.3
2
S.3
1
S.4
2
S.4
1
S.5
12" CONCRETE SLABW/ #5 @ 8" O.C. (T&B)
12" CONCRETE SLABW/ #5 @ 8" O.C. (T&B)
B-3
B-4
B-2
B-1
#4-5'-0" @ 8" O.C. (TOP)TYP. ALL AROUND
#4
-10
'-0
" @
8"
O.C
. (T
OP
)
#4
-5'-0
" @
8"
O.C
. (T
OP
)T
YP
. A
LL
AR
OU
ND
12" CONCRETE SLABW/ #5 @ 8" O.C. (T&B)
#5
@ 8
" O
.C. (T
&B
))
#5 @ 8" O.C. (T&B)
4
S.8
A
A
32' - 11"
37
' - 1
0"
10' - 0" 6' - 6" 5' - 11"
C1
2X
7.4
1
C1
2X
7.4
1
C1
2X
7.4
1
C1
2X
7.4
1
4.68°
B-1
B-1
B-2
B-2
B-2
C-1
C-1
C-1
C-2
C-3
B-4
B-4
B-4
ALUMINUM GUARDRAIL,REFER TO DETAILS
ALUMINUM GUARDRAIL,REFER TO DETAILS
11
' - 6
"2
' - 0
"1
1' -
6"
77
' - 1
0"
12' - 8"
5' - 5"
1
S.6
1
S.6
Sim
ALL EXPOSED CORNERVERTICAL AND HORIZONTALEDGES SHALL HAVE A 1 1/2" x1 1/2" CHAMFER EDGE TYP.
PROVIDE A 4x4x1/4" S.S.ANGLE W/ 4" LONG NELSONSTUDS @ EA. PUMP ANDACCESS HATCH OPENINGS,COORDINATE W/ MECHANICALSHOP DRAWINGS
4x4x1/4" ANGLE (TYP)ALUMINUM GRATING OR10" PRE-CASTCONCRETRE PLANK W/#5 @ 6" O.C. E.W.(BOTTOM)
ALUMINUM GRATING OR10" PRE-CASTCONCRETRE PLANK W/#5 @ 6" O.C. E.W.(BOTTOM)
9' - 10 7/8"
2
S.5
FOR REINFORCEMENT GRADE AND TYPE, REFER TO GENERAL NOTES ORSPECIFICATIONS.
FLOOR PLAN, NOTES AND SPECIFICATION SHALL READ IN CONJUNCTIONWITH ALL RELATED DISCIPLINES DOCUMENTS.
REFER TO CIVIL DOCUMENTS FOR STRUCTURE LOCATION ANDORIENTATION.
REFER TO GEOTECHNICAL REPORT FOR SOIL BEARING CAPACITY ANDFOUNDATION RECOMMENDATIONS.
COJNTRACTOR SHALL COORDINATE LOCATION OF SLAB OPENINGS, PIPEPENETRATION, PUMP ROOM ACCESS, PUMPS, AND ANY OTHERMECHANICAL AND ELECTRICAL EQUIPMENT PRIOR COMMENCING ANYWORK
ANY DISCREPANCY SHALL BE REPORTED IN WRITING TO ENGINEER OFRECORD FOR APPROVAL, PRIOR COMMENCING ANY WORK.
CONTRACTOR SHALL SUBMITT SHOP DRAWINGS FOR ALL STRUCTURALRELATED ITEMS INCLUDING MECHANICAL EQUIPMENT MOUNTING DETAILS.
REFER TO SHEET S-10 FOR ALL GRATING DETAILS AND SCHEDULE.
ALL DETAILS ARE INTENTED TO BE TYPICAL UNLESS NOTED OTHERWISE.
DO NOT SCALE DRAWINGS.
ID / SYMBOL DESCRIPTION
INDICATES SLAB @ DIFFERENT ELEVATION
. INDICATES TARGET ELEVATION
STEEL INDICATES REINFORCEMENT SIZE AND DIRECTION
INDICATES DIRECTION OF SLAB SPAN
A INDICATES GRIDE LINE ID.
INDICATES WALL TYPE1
INDICATES CENTER LINE
INDICATES STEP DOWN SLAB
ID / SYMBOL DESCRIPTION COLUMN TYPE REINFORCEMENT
12X38"C1
B1
C1
INDICATES COLUMN
INDICATES COLUMN BELOW
INDICATES CONCRETE BEAM
INDICATES SLAB OPENING
C2
C3
SIZE
(10) #6 VERTICAL AND #3 STIRRUPS @8" O.C.
12X25X25" (12) #6 VERTICAL AND #3 STIRRUPS @8" O.C.
12X25X25" (12) #6 VERTICAL AND #3 STIRRUPS @8" O.C.
BEAM TYPE REINFORCEMENT
12X24"
SIZE
(8) #6 CONTINOUS AND #3 STIRRUPS@ 12" O.C.
12X24"
12X24"
12X24"
(8) #6 CONTINOUS AND #3 STIRRUPS@ 12" O.C.
(8) #6 CONTINOUS AND #3 STIRRUPS@ 12" O.C.
(8) #6 CONTINOUS AND #3 STIRRUPS@ 12" O.C.
B-1
B-2
B-3
B-4
LEGEND NOTES COLUMN BEAM SCHEDULE
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PR
OF
E
SS
I O N A LE
NG
IN
EE
R
ST
AT
EO F F L O
RI
DA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
LEVEL 3 PLAN - EL. -0.5'
SCALE: 1/8" = 1'=0"0' 4' 8' 16' 32'
1
S-2
TOP SLAB - EL. +6.5'
SCALE: 1/8" = 1'=0"0' 4' 8' 16' 32'
2
S-2
FLOOR PLANSS-2
![Page 8: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/8.jpg)
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
1 2 3 4 5 6 72
S.4
1
S.5
S.8
1
S.8
2
19' - 6" 20' - 6" 9' - 2" 9' - 2" 9' - 2" 9' - 2"
S.8
3
4' - 6 1/4" 9' - 2" 9' - 2" 9' - 2" 4' - 7 3/4"
8' - 6"
2' - 0"
12" CONCRETE SLAB W/ # 5 @ 8"O.C. E.W. AND (T&B)
B-1, AS PER PLAN ANDSCHEDULE
12" CONCRETE WALL W/ # 5 @8" O.C. E.W. AND E.F.
FOUNDATION, AS PER PLAN
12" CONCRETE SLAB W/ # 5 @ 8"O.C. E.W. AND (T&B)
14" CONCRETE WALL W/ # 6 @6" O.C. E.W. AND E.F.
30" CONCRETE WALL W/ # 6 @8" O.C. E.W. AND T&B
FOUNDATION, AS PER PLAN
+/- 30" TREMIE GROUT
2
S.5
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
1 2 3 4 5 6 72
S.4
1
S.5
S.6
2S.6
3
19' - 6" 20' - 6" 9' - 2" 9' - 2" 9' - 2" 9' - 2"
2' - 7 7/8" 2' - 5" 2' - 5" 4' - 4 1/8" 2' - 5" 2' - 5" 4' - 4" 2' - 5" 2' - 5" 5' - 5"
1' - 4" 1' - 4"
3' - 11"
4' - 6 7/8" 4' - 7 1/8" 4' - 7" 4' - 7" 4' - 7" 4' - 7" 4' - 7" 4' - 7"
37' - 10"
7' - 6" 25' - 0" 7' - 6"
12" CONCRETE SLAB W/ #5 @8" O.C. E.W. AND E.F.
2 2 2
12" CONCRETE SLAB W/ #5 @8" O.C. E.W. AND E.F.
30" CONCRETE SLAB W/ #6@ 8" O.C. E.W. AND (T&B)
4
S.10
4
S.10
4
S.10
4
+/- 30" TREMIE GROUT
15
2
S.5
12" CONCRETE SLAB W/ #5@ 8" O.C. E.W. AND E.F.(BEYOND)
1
1
1
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LAKD
AS
N A N A YAK
KARA
PROFE
SSI O N A L
ENG
INEER
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
SECTION
SCALE: 1/4" = 1'=0"0' 2' 4' 8' 16'
1
S-3
SECTION
SCALE: 1/4" = 1'=0"0' 2' 4' 8' 16'
2
S-3
BUILDIDNG SECTIONSS-3
![Page 9: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/9.jpg)
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
1 2 3 4 5 6 72
S.4
1
S.5
S.7
3
S.7
2
S.7
1
S.7
4
19' - 6" 20' - 6" 9' - 2" 9' - 2" 9' - 2" 9' - 2"
7' - 6" 25' - 0" 44' - 9"
15
1
B-8, AS PER PLAN
B-7, AS PER PLAN, (BEYOND)
12" CONCRETE SLAB AS PER PLAN
30" CONCRETE SLAB AS PER PLAN
22
2
12" CONCRETE SLAB AS PER PLAN
30" CONCRETE SLAB AS PER PLAN
S.8
4
STEEL GRATING, AS PER PLAN
541
2
S.5
12" CONCRETE SLAB AS PER PLAN
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
B C D1
S.3
2
S.3
1
S.4
S.9
1
S.9
2
22' - 5" 7' - 3"
4' - 8" 6' - 1" 11' - 8"
MANUFACTURER
COORDINATE W/ PUMP
MANUFACTURER
COORD. W/ PUMP12" CONCRETE SLAB W/#5 @ 8" O.C. E.W. AND(T&B)
30" CONCRETE SLAB W/#6 @ 8" O.C. E.W. AND(T&B)
CONCRETE BEAM,BEYOND
12" CONCRETE SLAB W/#5 @ 8" O.C. E.W. AND(T&B)
30" CONCRETE SLAB W/#6 @ 8" O.C. E.W. AND(T&B)
CONCRETE BEAM ASPER PLAN
11
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PR
OF
E
SS
I O N A LE
NG
IN
EE
R
ST
AT
EO F F L O
RI
DA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
SECTION
SCALE: 1/4" = 1'=0"0' 2' 4' 8' 16'
1
S-4
SECTION
SCALE: 1/4" = 1'=0"0' 2' 4' 8' 16'
2
S-4
BUILDING SECTIONSS-4
![Page 10: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/10.jpg)
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
B C D1
S.3
2
S.3
1
S.4
S.9
3
4
S.8
4' - 8" 6' - 1" 11' - 8"
22' - 5" 7' - 3"
MANUFACTURER
COORDINATE W/ PUMP
12" CONCRETE SLAB W/ #5 @ 8" O.C. E.W. AND(T&B)
1
2
CONCRETE BEAM,BEYOND
30" CONCRETE SLAB W/#6 @ 8" O.C. E.W. AND(T&B)
CONCRETE BEAM, ASPER PLAN
12" CONCRETE SLAB W/ #5 @ 8" O.C. E.W. AND(T&B)
OPEN
12" CONCRETE WALL W/ #6 @ 8" O.C. E.W. AND E.F.,(BEYOND)
S.9
1Sim
S.9
2Sim
1
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
B C D2
S.3
1
S.4
1
S.6
22' - 5" 7' - 3"
10' - 0" 6' - 6" 18' - 7"
0' - 6"6' - 1"6' - 0"6' - 0"
12' CONCRETE SLAB W/ # 6@ 8" O.C. E.W. AND (T&B)
30" CONCRETE SLAB W/ #6 @ 8" O.C. E.W. AND (T&B)
8" CONCRETE SLAB W/ # 5@ 8" O.C. E.W. AND (T&B)
S.9
4
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LAKD
AS
N A N A YAK
KARA
PROFE
SSI O N A L
ENG
INEER
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
SECTION
SCALE: 1/4" = 1'=0"0' 2' 4' 8' 16'
1
S-5
BUILDING SECTIONSS-5
SECTION
SCALE: 1/4" = 1'=0"0' 2' 4' 8' 16'
2
S-5
![Page 11: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/11.jpg)
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
3 42
S.4
9' - 2"
2' - 5" 2' - 5"
4' - 7" 4' - 7"
2' - 7 7/8" 4' - 4 1/8"
COORDINATE W/ PUMP MANUFACTURER
12" CONCRETE WALL W/ # 6 @8" O.C. E.W. AND E.F.
#4 - STD 90 @ 8" O.C.
#6 STD. 90 BAR @ 8" O.C.
30" CONCRETE WALL W/ # 6 @8" O.C. E.W. AND E.F.
CONCRETE BEAM W/ (5) #5CONT., (T&B), AND #3 STIRRUPS@ 6" O.C.
CONCRETE BEAM W/ (7) #5CONT., (T&B), AND #3 STIRRUPS@ 6" O.C.
7' - 0"
7' - 0"
Level 1-8' - 6"
Level 1-8' - 6"
Level 2-4' - 0"
Level 2-4' - 0"
Level 30' - 11"
Level 30' - 11"
Level 46' - 6"
Level 46' - 6"
6 79' - 2"
4' - 7" 4' - 7"
EQ EQ
VERIFY W/ PUMP MANUFACTURER
12" CONCRETE SLAB AS PER PLAN
#4 - STD. 90 @ 8" O.C.
12" CONCRETEWALL W/ #6 @ 8"O.C. E.W. AND E.F.
#6 STD. 90 @ 8" O.C.
CONCRETE BEAM W/ (9) #5 CONT.,(T&B), AND #3 STIRRUPS @ 6" O.C.
CONCRETE BEAM W/ (8) #5 CONT.,AND #3 STIRRUPS @ 6" O.C.
5' - 5" 3' - 11"
14" CONCRETEWALL W/ #6 @ 6"O.C. E.W. AND E.F.
30" CONCRETE SLAB W/ #6 @ 8"O.C. E.W. AND (T&B)
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
1
CONCRETE COLUMN, (C-4), W/ (6)# 6 VERTICAL AND # 3 STIRRUPS@ 8" O.C.
12" CONCRETE WALL W/ #6 @8" O.C. E.W. AND E.F.
#6 STD. 90 @ 8" O.C.
24" CONCRETE SLAB W/ #6 @ 8"O.C. E.W. AND (T&B).
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LAKD
AS
N A N A YAK
KARA
PROFE
SSI O N A L
ENG
INEER
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
1
S-6
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
2
S-6
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
3
S-6
WALL SECTIONSS-6
![Page 12: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/12.jpg)
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
1
#4- STD. 90 BAR @ 8" O.C.
12" CONCRETE SLAB W/ #5 @ 8" O.C. E.W. AND(T&B).
30" CONCRETE SLAB W/ #6 @ 8" O.C. E.W. AND(T&B).
#4 STD. 90 BAR @ 8"O.C.
14" CONCRETE WALL W/#6 @6" O.C. E.W. AND E.F.
S.10
4
KEYED JOINT W/ WATERSTOP
KEYED JOINT W/ WATERSTOP
14' - 0"
12" CONCRETE WALL W/#6 @8" O.C. E.W. AND E.F.
+/- 30" TREMIE GROUT
2
S.5
KEYED JOINT W/ WATERSTOP
#6 STD. 90 BAR @ 8"O.C.
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
2
24" CONCRETE WALL W/ #6 @8" O.C. E.W. AND E.F.
#4 STD 90 BAR @ 8" O.C.
30" CONCRETE SLAB W/ #6 @8" O.C. E.W. AND (T&B)
2x2 KEYED JOINT W/ WATERSTOP
S.10
4
S.10
4
C12X7.41, AS PER PLAN
ALUMINUM GRATING
+/- 30" TREMIE GROUT
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
3
#4 - STD 90 @ 8" O.C. (TOP)
12" CONCRETE SLAB W/ #5@ 8" O.C. E.W. AND (T&B)
32x12 CONCRETE BEAM W/(8) #5 CONT. AND # 3STIRRUPS @ 8" O.C.
12" CONCRETE WALL W/ #6@ 8" O.C. E.W. AND E.F.
8' - 0"
#6 STD 90 @ 8" O.C.
30" CONCRETE SLAB W/ #6@ 8" O.C. E.W. AND (T&B)
S.10
4
7' - 0"
7' - 0"
CONSTRUCTION JOINT W/WATER STOP
CONSTRUCTION JOINT W/WATER STOP
CONSTRUCTION JOINT W/WATER STOP
#4 STD 90 @ 8" O.C.
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
7
#4 - STD 90 @ 8" O.C. (TOP)
12" CONCRETE SLAB W/ # 5@ 8" O.C. E.W. AND (T&B)
CONCRETE BEAM 48x12 W/(8) # 5 CONT. AND #3STIRRUPS @ 8" O.C.
14" CONCRETE WALL W/ # 6@ 6" O.C. E.W. AND E.F.
#6 - STD 90 @ 8" O.C. (TOP)
30" CONCRETE SLAB W/ # 5@ 8" O.C. E.W. AND (T&B)
7' - 0"
7' - 0"
+/- 30" TREMIE GROUT
JOINT W/ WATER STOP.
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PRO
FE
SS
I O N A LENG
INEER
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
1
S-7
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
2
S-7
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
3
S-7
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
4
S-7
WALL SECTIONSS-7
![Page 13: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/13.jpg)
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
3
2
S.4
4' -
0"
6' -
6"
4' - 7 1/8"
PUMP MANUFACTURER
COORDINATE W/ MECH. DWGS.
8' -
6"
2' -
0"
12" CONCRETE SLAB W/ 5 @ 8" O.C.E.W. AND E.F.
CONCRETE BEAM, (B-3), REFER TOSCHEDULE
#4 - 8'-0" @ 8" O.C. (TOP)
12" CONCRETE WALL W/ #6 @ 8"O.C. E.W. AND E.F.,(BEYOND)
ALUMINUM GUARDRAIL, REFER TODETAILS
30" CONCRETE SLAB W/ #6 @ 8"O.C. E.W. AND (T&B)
24" CONCRETE SLAB (BEYOND)
+/- 30" TREMIE GROUT
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
7
2' - 3"
EQ EQ
PU
MP
MA
NU
FA
CT
UR
ER
VE
RIF
Y W
/
12" CONCRETE SLAB W/ # 5 @ 8"O.C. E.W. AND (T&B)
#4 STD 90 @ 8" O.C. (TOP)
14" CONCRETE WALL W/ # 6 @ 6"O.C. E.W. AND E.F.
30" CONCRETE SLAB W/ # 6 @ 8"O.C. E.W. AND (T&B)
#6 - 60 dia. BAR, SPLICE
+/- 30" TREMIE GROUT
KEYED JOINT W/ WATER STOP
Level 30' - 11"
Level 46' - 6"
51
S.5
#6
@ 8
" O
.C. E
.F.
#6@ 8" O.C. E.F.
AS PER DTL.
12" CONCRETE SLAB W/ #5 @ 8" O.C. E.W. AND E.F.
4' -
0"
4' - 6 1/2" 4' - 7 1/8"
AS PER DTL.
Level 46' - 6"
5
B-3, CONCRETE BEAM W/ (16) #5CONT. AND #3 STIRRUPS @ 8" O.C.
B-8, CONCRETE BEAM W/ (8) #6CONT. AND #3 STIRRUPS @ 8" O.C.
12" CONCRETE SLAB W/ #5 @ 8"O.C. E.W. AND (T&B).
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PR
OF
E
SS
I O N A LE
NG
IN
EE
R
ST
AT
EO F F L O
RI
DA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
1
S-8
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
2
S-8
DETAIL
SCALE: 1/2" = 1'=0"
3
S-80' 1' 2'
DETAIL
SCALE: 3/4" = 1'=0"
4
S-80' 1' 2'
WALL SECTIONS AND DETAILS-8
![Page 14: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/14.jpg)
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
12" CONCRETE SLAB W/ #5 @ 8" O.C. E.W. AND (T&B)
CONCRETE BEAM AS PERPLAN
WALL OPNG. REFER TOMECH. DOCUMENTS
12" CONCRETE WALL W/# 5 @ 8" O.C. E.W. ANDE.F.
12" CONCRETE WALL W/# 5 @ 8" O.C. E.W. ANDE.F.
30" CONCRETE SLAB W/ #6 @ 8" O.C. E.W. AND(T&B)
+/- TREMIE GROUT
DW
GS
.
SEE M
EC
H.
2' -
0"
SE M
EC
H. D
WG
S.
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
B1
S.3
DW
GS
SEE M
EC
H
DW
GS
.
REFER
TO
MEC
HR
EFER
TO
MEC
H. D
WG
S.
12" CONCRETE SLAB W/ #5@ 8" O.C. E.W. AND (T&B)
CONCRETE BEAM, AS PERPLAN
12" CONCRETE WALL W/ #5@ 8" O.C. E.W. AND E.F.
#5 @ 8" O.C. E.W.
24" CONCRETE SLAB W/ #6@ 8" O.C. E.W. AND (T&B)
24" CONCRETE SLAB W/ #6@ 8" O.C. E.W. AND (T&B)
# 6 STD. 90 BAR @ 8" O.C.
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
C1
S.4
79.87°
6' - 7" 3' - 7 1/8"
CONCRETE BEAM AS PERPLAN
12" CONCRETE WALL W/ #6 @ 8" O.C. E.W. AND E.F.
OPEN
12" CONCRETE SLAB W/ #5@ 8" O.C. E.W. AND (T&B)
#4 @ 8" O.C.
12" CONCRETE SLAB W/ #6 @ 8" O.C. E.W. AND(T&B)
#4 @ 8" O.C.
#5 @ 8" O.C.
#5 @
8" O
.C.
+/- 30" TREMIE GROUT
Level 1-8' - 6"
Level 2-4' - 0"
Level 30' - 11"
Level 46' - 6"
1
S.4
S.10
3
3
1
CONCRETE SLAB AS PERPLAN (BEYOND)
ALUMINUM GRATING ORPRECAST SLAB
12" CONCRETE SLAB W/ # 5 @8" O.C. E.W. AND (T&B)
30" CONCRETE SLAB W/ # 6@ 8" O.C. E.W. AND (T&B)
12" CONCRETE WALL, AS PERPLAN
KEYED JOINT W/ WATERSTOP
#4 STD. 90 @ 8" O.C.
30" TREMIE GROUT
6' - 6"
#5 STD. 90 @ 8" O.C.
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PR
OF
E
SS
I O N A LE
NG
IN
EE
R
ST
AT
EO F F L O
RI
DA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
1
S-9
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
2
S-9
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
3
S-9
WALL SECTIONS AND DETAILS-9
WALL SECTION
SCALE: 1/2" = 1'=0"0' 1' 2'
4
S-9
![Page 15: dnhiggins.comdnhiggins.com/docs/LERI Addendum 1 Plans 3.pdf · the following symbols may be used throughout drawings to refer to other views: a s1.03 a ... c manual of standard practice](https://reader031.vdocuments.site/reader031/viewer/2022022603/5b5ba6ed7f8b9a905c8e799e/html5/thumbnails/15.jpg)
PROVIDE MIN. LAP AS NOTED OR SHOWN ON DRAWINGS.
TYPICAL FOR ALL CONCRETE WALLS AND SLABS UNLESSOTHERWISE INDICATED ON DRAWINGS.
FOR ROUND OPENINGS LESS THAN 12", USEREINFORCEMENT PATTERN SAME AS FOR RECTANGULAROPENINGS.
NOTES:
REINFORCEMENT CUT, ("A" BARS)
REINFORCEMENT CUT, ("B" BARS)
(1) #5 DIAGONAL AT EA. CORNERFOR EA. LAYER OFREINFORCEMENT
(TYP.)2'
- 0"
X
X
BARS CUT
AREA OF BARS EQUAL "B"
BARS CUT
AREA OF BARS EQUAL "A"
BARS CUT
AREA OF BARS EQUAL "A"
BARS CUT
AREA OF BARS EQUAL "B"
INDICATES GRATING SPAN DIRECTION. (SEE PLANS)
SHOP DRAWINGS BASED ON FIELD DIMENSIONS SHALL BE SUBMITTED TOTHE ENGINEER OF RECORD PRIOR FABRICATION.
GRATING AND GRATING SUPPORTS SHALL BE THE SAME MATERIAL.
UNLESS NOTED OTHERWISE ON PLANS, GRATING THICKNESS SHALL BEAS NOTED IN TABLE BELOW. MINIMUM BEARING BAR THICKNESS SHALLBE 3/16".
ALL EDGES SHALL HAVE A BAND 1/4" X BEARING BAR DEPTH.
MAXIMUM WIDTH OF GRATING SECTIONS SHALL BE 3'-0" UNLESSINDICATED OTHERWISE ON PLANS.
PROVIDE GRATING FASTENING SYSTEM AS REQUIRED.
STEEL GRATING AND SUPPORTS TO BE GALVANIZED UNLESS NOTEDOTHERWISE ON PLANS.
NOTCH GRATING SUPPORTS AT GATES AS REQUIRED. EXTEND GRATINGCONTINUOUSLY OVER GATE GUIDES AND GATES.
GRATING SUPPORTS SHALL BE MATERIAL TYPE SHOWN ON PLANS ORSPECIFIED. THIS IS A STANDARD DETAIL ILLUSTRATING 3 DESIGNMATERIALS ALTHOUGH ALL 3 MATERIAL MAY BE INCLUDED IN THEPROJECT.
GRATING NOTES GRATING THICKNESS TABLE
MAXIMUM SPAN ALUMINUM STEEL FIBERGLASS
3'-6"
4'-0"
4'-6"
5'-0"
5'-6"
6'-0"
6'-6"
7'-0"
1 1/4"
1 1/2"
1 3/4"
1 3/4"
2"
2 1/4"
2 1/4"
2 1/2"
1"
1 1/4"
1 1/4"
1 1/2"
1 1/2"
1 3/4"
1"
1"
1 1/2"
1 1/2"
MAX. SPANALLOWABLE IS 4'-0"
(ALLOWABLEDEFLECTION 1/4"MAX.)
SUPPORT TYPE 1SUPPORT TYPE 2
GRATING, SEE PLAN
FASTENERS AS PERGRATING SYSTEM MFRSRECOMMENDATIONS
SUPPORT MEMBERSEE DWGS. FORSIZE, TYPE & ENDCONDITIONS
GRATING, SEE PLAN
FASTENERS AS PERGRATING SYSTEM MFRSRECOMMENDATIONS
SUPPORT ANGLE4 X 4 X 1/4 ( ALUM OR SST)
GRATINGTHICKNESS(SEE SCHD)
GRATINGTHICKNESS(SEE SCHD)
0' - 4"
0' - 1 1/2"
1' - 0"
(TYP)
0' - 1 1/2"
0' - 1 1/2"5/8" SST BOLTSNUTS & WASHERS
1/4" SST ANGLE3" X 4" X 10" LONG
1/2" RETURN ATTOP & BOTTOM 1/4
3/4" X 6" S.S. ANCHORSTUDS @ 6" GAGEEQ. SPACED
SST WELD PLATE1/2" X 6" X 12"
TOP OF GRATING TO MATCH TOP OF WALL
ALUM C12X7.41W/ BOLTS SLOTS5/8" DIA 1 1/2" LONG
HANDRAILPOST
1/2" PL2-5/8" X 6"
BEAM FLG.
5/8" SST BOLTS
(TYP)
0' - 3"
(TYP)0' - 0 7/8"
0' - 3 3/4"
0' - 2 3/4"
HANDRAIL POST
0' - 0 7/8" (TYP)
STAIRSTRINGERFLG
5/8" SST BOLTS
1/4
BEAM CONNECTION STAIR STRINGER
NOTES: 1) BASE PLATE, HANDRAIL & POT TO BE SAME MATERIAL. PROVIDE PROTECTION FOR DISSIMILAR METALS AND CONCRETE AS PER SPECIFICATIONS.
2) WELD POST CONNECTION AS SHOWN FOR STEEL & STAINLESS STEEL. FOR ALUMINUM PROVIDE CONNECTION DEVELOPING FULL PIPE STRENGHT FOR SHOP DRAWING REVIEW.
POST EQUAL SPACED5' - 0" MAX
1' - 3"
1' - 1 1/2"1' - 1 1/2"
TOE BOARDWHERE SHOWNON DRAWINGS
3' - 6"
HANDRAIL POSTACHORAGE
0' - 1 1/2" (M
IN.)
CONCTRUCTION JOINTROUGH & CLEAR PRIORTO WALL POUR
3/16" X 6" WATERSTOP AS SPECIFIED& LOCATED ON DRAWINGS
SLAB AS SHOWN ONDRAWINGS
WALL AS DETAILEDON DRAWINGS
TYPICAL DOUBLE MAT CORNER
AND INTERSECTION REINFORCING
STD ACI-31890 HOOK
TYPICAL HORIZONTALWALL REINFORCING ASSHOWN ON DRAWINGS
ALTERNAE LAPON SIDE OF WALLIN NEXT LAYER
STD ACI-31890 HOOK
ADDITIONAL CORNERREINFORCINGBAR (SAME SIZE ANDSPACING AS O.F.HORIZONTAL WALLREINFORCING )
40 BAR DIA
40 BAR DIA
STD ACI-31890 HOOK
(2) 5/8" SSTEPOXY BOLTS
HANDRAILPOST
1/2" PL4" X 6"
1/4
PLAN ELEVATION
0' - 3" 0' - 3"
0' - 6"
0' - 4"
LAKDAS/YOHALEM ENGINEERING, INC.
e-mail: [email protected](954) 771-0630 FAX: (954) 771-0519
CONSULTING ENGINEERS2211 NE 54TH ST. - FT. LAUDERDALE FL 33308
1800 Eller Drive, Suite 600, Fort Lauderdale,
Florida 33316
Phone: 954.921.7781 � Fax: 954.921.8807
TM
Calvin, Giordano &
Associates, Inc.
LA
KD
AS
N A N A YA
K
KA
RA
PRO
FE
SS
I O N A LENG
INEER
STAT
EO F F L O
RIDA
P.E. # 037590
R
It's fast. It's free. It's the law.
www.callsunshine.com
KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIG
EXPANDED LLOYD ESTATES
RESIDENTIAL AND INDUSTRIAL
IMPROVEMENT PLANCITY OF OAKLAND PARK, FL.NONO DATE REVISION BY
ISSUED FOR
REVISIONDATE DATEBY
DATEDESIGNED
DATECHECKED
SCALE
PURPOSE OF THIS SET
PROJECT No
SHEET:AS NOTED
152201
PERMITTING
LN
2-29-15
PERMIT
WALL / SLAB OPNG. DETAIL
SCALE: N.T.S.
1
S-10
GRATING SCHEDULE
SCALE: N.T.S.
2
S-10
GRATING DETAIL
SCALE: N.T.S.
3
S-10
GRATING DETAIL
SCALE: N.T.S.
4
S-10
RAILING DETAIL
SCALE: N.T.S.
5
S-10
RAILING DETAIL
SCALE: N.T.S.
6
S-10
REINFORCEMENT DETAIL
SCALE: N.T.S.
8
S-10
SLAB / WALL CONNECTION DTL.
SCALE: N.T.S.
7
S-10
GUARDRAIL POST DETAIL
SCALE: N.T.S.
9
S-10
DETAILSS-10