active infrared (retro-reflective) counters version 0.0
TRANSCRIPT
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
Active Infrared (through-beam) Counter
Version 3.0
To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar.
To advance the slides backward, use one of the following keys: PageUp, Left Arrow (), Up Arrow (), or BackSpace.
To exit the presentation at any time, press the escape (Esc) key or click the yellow Exit button at the bottom right of the screen.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
Active Infrared (through-beam) Counter
Version 3.0
To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar.
To advance the slides backward, use one of the following keys: PageUp, Left Arrow (), Up Arrow (), or BackSpace.
To exit the presentation at any time, press the escape (Esc) key or click the yellow Exit button at the bottom right of the screen.
You can go directly to topics by
selecting then clicking on a topic at the
bottom of the screen.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
Active Infrared (through-beam) Counter
Version 3.0
TrailMaster Model TM1550
(with 4K Memory)
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETrailMaster Model TM1550
Sight line for alignment with
transmitter
Power SwitchPress TIME SET
and SET UP buttons
simultaneously.
Data Port(for optional data collector unit)
Camera Connector(for optional accessory) Power
Switch
Red alignment indicator light
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
TM1550—Installation Instructions
Step 1. In forested locations, select a site along the trail with up to 10” diameter trees on both sides of the trail. The extra set(s) of straps (included with your counter) can be used to lengthen the straps, thus allowing the attachment to large diameter trees.
Step 2. Mount the Receiver unit (with nylon straps, provided on the unit) to one tree, with the sensor (located on the right side of the unit) facing the opposite tree. (Note, use the alignment sighting line to aim the receiver’s sensor in the direction of the opposite tree where the Transmitter unit will be mounted.)
Recommended Tools: Screwdriver, (Philips head)
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
TM1550—Installation Instructions
Step 3. Turn “on” the Receiver unit’s power switch and press the “Set Up” button on the front of the unit.
Step 4. Mount the Transmitter unit on the opposite tree (up to 150 feet away). Note, the sensor of the transmitter is located on the front face of the unit. This sensor should be aiming back towards the Receiver unit. Turn the power switch on.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
TM1550—Installation Instructions
Step 6. Tighten all mounting straps on each unit. Then, take several passes back and forth on the trail to verify that the counter is counting. If not, reposition the Receiver unit to align the sensor’s beam.
Step 5. At this time, you should notice the “red” alignment indicator on the Receiver unit blinking indicating the transmitter and receiver units are initially aligned.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
This section will illustrate how to set up the TIME and DATE function for the receiver unit.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
mm.dd
TIME and DATE Setting
…the display will toggle between time and date for several seconds, then display the total counts.
press press
Turn the receiver unit on.
hh:mmmm.ddhh:mmxx
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
hh:mm
pressandhold
next, hold down the TIME SET button for five seconds.
…the display will show the time with the hours blinking.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
hh:mm
press
press the R/O ADV button to advance the hour (0-24).
…the hour number will advance from 0 to 24 each time the R/O ADV button is pressed.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
hh:mm
pressonce
To change the minutes, press the TIME SET button once.
…the display will show the time with the minutes blinking.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
hh:mm
press
press the R/O ADV button to advance the minutes (01-59).
…the minutes number will advance from 01 to 59 each time the R/O ADV button is pressed.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
pressonce
yr xx …the display will show the year with the second to last digit of the year blinking.
To change the year, press the TIME SET button once.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
press
yr 0x …the number will advance each time the R/O ADV button is pressed.
press the R/O ADV button to advance the number (0-9).
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
pressonce
yr 0x …the display will show the year with the last digit of the year blinking.
press the TIME SET button again to change the last digit of the year.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
yr 04 …the number will advance each time the R/O ADV button is pressed.
press
press the R/O ADV button to advance the number (0-9).
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
pressonce
mm.dd …the display will show the month and day. The month number will be blinking.
To change the month and day, press the TIME SET button once.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
7.dd
press
press the R/O ADV button to advance the number (1-12).
…the month will advance each time the R/O ADV button is pressed.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
7.dd
pressonce
To change the day, press the TIME SET button once.
…the display will show the month and day. The date number will be blinking.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
7.14
press
press the R/O ADV button to advance the number (1-31).
…the day will advance each time the R/O ADV button is pressed.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMETIME and DATE Setting
7.14
press
press the TIME SET button when done.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEChanging PULSE RATE
2
This section will illustrate how to adjust the pulse rate function for the receiver unit.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEChanging PULSE RATE
press the TIME SET button twice.
presstwice
-P 2 …the display will show the pulse rate - P and blinking number from 1 through 30.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEChanging PULSE RATE
press the R/O ADV button to change the rate from 1 to 30. Tip: use 5 for pedestrians or 2 for vehicles.
-P 5
press
…the display will show the pulse rate - P and blinking number from 1 through 30.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
3867
CLEARING EVENT DATA
This section will illustrate how to set clear or “zero” the counter.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
S. uP
Press
“Resetting the Counter”
CLEARING EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
c lr
Press
“Resetting the Counter”
CLEARING EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
0
Press
“Resetting the Counter”
CLEARING EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
0 The counter is now ready to begin counting.
CLEARING EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEREAD OUT of EVENT DATA
386
This section will illustrate how read out the event data from the receiver unit.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEREAD OUT of EVENT DATA
Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter was started
Time
Log noXX
Recorded Counts
12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30
To extract your collected date/time-stamped data from the counter, do the following...
386
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEREAD OUT of EVENT DATA
386 Note, the number displayed is the total counts (cumulative) for the entire sampling period.
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
To find out when these counts occurred, do the following . . .
READ OUT of EVENT DATA
Note, the number displayed is the total counts (cumulative) for the entire sampling period.
386
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
1Press here
12. 1 …the date will appear (month.day)
READ OUT of EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
2Press here
again
15.31 …the time will appear (hour.minute)
READ OUT of EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
3Press here
again
1 …the count will appear
Note, the count displayed is a cumulative total of successive counts.
READ OUT of EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
4Press here
again
…when this message is displayed it indicates you have reached the end of the recorded counts.
Ehru
READ OUT of EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter was started
Time
Log noXX
Recorded Counts
12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30
You should be recording this information onto the form. The form enclosed with your shipment may be different from the one shown here.
READ OUT of EVENT DATA
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOMEOperating Specs TM1550
power source Four “C” Batteries (transmitter unit)
Four “C” Batteries (receiver unit)
battery life 8 monthsweight & dimensions 1 lb (receiver)
10 oz (transmitter)range (separation between transmitter and receiver)
150 ft.
adjustable sensitivity (pulse rate)
yes
non-volatile data memory
yes
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA
CLEARING EVENT DATA
HOME
TM1500—Product Service Information
Goodson and Associates, Inc.10614 WidmerLenexa, KS 66215Contact: Bill GoodsonPhone: 913-345-8555 or