active infrared (retro-reflective) counters version 0.0

41
TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA CLEARING EVENT DATA HOME Active Infrared (through- beam) Counter Version 3.0 To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar. To advance the slides backward, use one of the following keys: PageUp, Left Arrow (), Up Arrow (), or BackSpace. To exit the presentation at any time, press the escape (Esc) key or click the yellow Exit button at the bottom right of the screen.

Upload: hoangdien

Post on 18-Jan-2017

229 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

Active Infrared (through-beam) Counter

Version 3.0

To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar.

To advance the slides backward, use one of the following keys: PageUp, Left Arrow (), Up Arrow (), or BackSpace.

To exit the presentation at any time, press the escape (Esc) key or click the yellow Exit button at the bottom right of the screen.

Page 2: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

Active Infrared (through-beam) Counter

Version 3.0

To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar.

To advance the slides backward, use one of the following keys: PageUp, Left Arrow (), Up Arrow (), or BackSpace.

To exit the presentation at any time, press the escape (Esc) key or click the yellow Exit button at the bottom right of the screen.

You can go directly to topics by

selecting then clicking on a topic at the

bottom of the screen.

Page 3: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

Active Infrared (through-beam) Counter

Version 3.0

TrailMaster Model TM1550

(with 4K Memory)

Page 4: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETrailMaster Model TM1550

Sight line for alignment with

transmitter

Power SwitchPress TIME SET

and SET UP buttons

simultaneously.

Data Port(for optional data collector unit)

Camera Connector(for optional accessory) Power

Switch

Red alignment indicator light

Page 5: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

TM1550—Installation Instructions

Step 1. In forested locations, select a site along the trail with up to 10” diameter trees on both sides of the trail. The extra set(s) of straps (included with your counter) can be used to lengthen the straps, thus allowing the attachment to large diameter trees.

Step 2. Mount the Receiver unit (with nylon straps, provided on the unit) to one tree, with the sensor (located on the right side of the unit) facing the opposite tree. (Note, use the alignment sighting line to aim the receiver’s sensor in the direction of the opposite tree where the Transmitter unit will be mounted.)

Recommended Tools: Screwdriver, (Philips head)

Page 6: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

TM1550—Installation Instructions

Step 3. Turn “on” the Receiver unit’s power switch and press the “Set Up” button on the front of the unit.

Step 4. Mount the Transmitter unit on the opposite tree (up to 150 feet away). Note, the sensor of the transmitter is located on the front face of the unit. This sensor should be aiming back towards the Receiver unit. Turn the power switch on.

Page 7: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

TM1550—Installation Instructions

Step 6. Tighten all mounting straps on each unit. Then, take several passes back and forth on the trail to verify that the counter is counting. If not, reposition the Receiver unit to align the sensor’s beam.

Step 5. At this time, you should notice the “red” alignment indicator on the Receiver unit blinking indicating the transmitter and receiver units are initially aligned.

Page 8: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

This section will illustrate how to set up the TIME and DATE function for the receiver unit.

Page 9: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

mm.dd

TIME and DATE Setting

…the display will toggle between time and date for several seconds, then display the total counts.

press press

Turn the receiver unit on.

hh:mmmm.ddhh:mmxx

Page 10: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

hh:mm

pressandhold

next, hold down the TIME SET button for five seconds.

…the display will show the time with the hours blinking.

Page 11: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

hh:mm

press

press the R/O ADV button to advance the hour (0-24).

…the hour number will advance from 0 to 24 each time the R/O ADV button is pressed.

Page 12: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

hh:mm

pressonce

To change the minutes, press the TIME SET button once.

…the display will show the time with the minutes blinking.

Page 13: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

hh:mm

press

press the R/O ADV button to advance the minutes (01-59).

…the minutes number will advance from 01 to 59 each time the R/O ADV button is pressed.

Page 14: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

pressonce

yr xx …the display will show the year with the second to last digit of the year blinking.

To change the year, press the TIME SET button once.

Page 15: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

press

yr 0x …the number will advance each time the R/O ADV button is pressed.

press the R/O ADV button to advance the number (0-9).

Page 16: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

pressonce

yr 0x …the display will show the year with the last digit of the year blinking.

press the TIME SET button again to change the last digit of the year.

Page 17: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

yr 04 …the number will advance each time the R/O ADV button is pressed.

press

press the R/O ADV button to advance the number (0-9).

Page 18: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

pressonce

mm.dd …the display will show the month and day. The month number will be blinking.

To change the month and day, press the TIME SET button once.

Page 19: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

7.dd

press

press the R/O ADV button to advance the number (1-12).

…the month will advance each time the R/O ADV button is pressed.

Page 20: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

7.dd

pressonce

To change the day, press the TIME SET button once.

…the display will show the month and day. The date number will be blinking.

Page 21: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

7.14

press

press the R/O ADV button to advance the number (1-31).

…the day will advance each time the R/O ADV button is pressed.

Page 22: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMETIME and DATE Setting

7.14

press

press the TIME SET button when done.

Page 23: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEChanging PULSE RATE

2

This section will illustrate how to adjust the pulse rate function for the receiver unit.

Page 24: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEChanging PULSE RATE

press the TIME SET button twice.

presstwice

-P 2 …the display will show the pulse rate - P and blinking number from 1 through 30.

Page 25: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEChanging PULSE RATE

press the R/O ADV button to change the rate from 1 to 30. Tip: use 5 for pedestrians or 2 for vehicles.

-P 5

press

…the display will show the pulse rate - P and blinking number from 1 through 30.

Page 26: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

3867

CLEARING EVENT DATA

This section will illustrate how to set clear or “zero” the counter.

Page 27: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

S. uP

Press

“Resetting the Counter”

CLEARING EVENT DATA

Page 28: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

c lr

Press

“Resetting the Counter”

CLEARING EVENT DATA

Page 29: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

0

Press

“Resetting the Counter”

CLEARING EVENT DATA

Page 30: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

0 The counter is now ready to begin counting.

CLEARING EVENT DATA

Page 31: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEREAD OUT of EVENT DATA

386

This section will illustrate how read out the event data from the receiver unit.

Page 32: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEREAD OUT of EVENT DATA

Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter was started

Time

Log noXX

Recorded Counts

12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30

To extract your collected date/time-stamped data from the counter, do the following...

386

Page 33: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEREAD OUT of EVENT DATA

386 Note, the number displayed is the total counts (cumulative) for the entire sampling period.

Page 34: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

To find out when these counts occurred, do the following . . .

READ OUT of EVENT DATA

Note, the number displayed is the total counts (cumulative) for the entire sampling period.

386

Page 35: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

1Press here

12. 1 …the date will appear (month.day)

READ OUT of EVENT DATA

Page 36: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

2Press here

again

15.31 …the time will appear (hour.minute)

READ OUT of EVENT DATA

Page 37: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

3Press here

again

1 …the count will appear

Note, the count displayed is a cumulative total of successive counts.

READ OUT of EVENT DATA

Page 38: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

4Press here

again

…when this message is displayed it indicates you have reached the end of the recorded counts.

Ehru

READ OUT of EVENT DATA

Page 39: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter was started

Time

Log noXX

Recorded Counts

12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30

You should be recording this information onto the form. The form enclosed with your shipment may be different from the one shown here.

READ OUT of EVENT DATA

Page 40: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOMEOperating Specs TM1550

power source Four “C” Batteries (transmitter unit)

Four “C” Batteries (receiver unit)

battery life 8 monthsweight & dimensions 1 lb (receiver)

10 oz (transmitter)range (separation between transmitter and receiver)

150 ft.

adjustable sensitivity (pulse rate)

yes

non-volatile data memory

yes

Page 41: Active Infrared (retro-reflective) Counters Version 0.0

TIME and DATE Setting Changing PULE RATE READ OUT of EVENT DATA

CLEARING EVENT DATA

HOME

TM1500—Product Service Information

Goodson and Associates, Inc.10614 WidmerLenexa, KS 66215Contact: Bill GoodsonPhone: 913-345-8555 or

1-800-544-5415Fax: 913/345-8272Website: www.trailmaster.com