acf bonding tests for the alice trd signal cablescern.ch/ssd-rd/bond/talks/4-05_emschermann.pdf ·...
TRANSCRIPT
Workshop onBonding Technologies
ACF bonding tests for theALICE TRD signal cables
David Emschermann
Physikalisches Institut
University of Heidelberg
Bonding Workshop – CERN 11-12/06/2003 – p.1/26
The ALICE TRD
Bonding Workshop – CERN 11-12/06/2003 – p.2/26
The ALICE detector
5
6
7
3
13
11
1010
12
9
1
2
44
14
1516
8
Stephane Maridor (CERN div.EST) / Jean-Luc Caron (CERN div.AC) 31/07/2000
01. I.T.S.
02. F.M.D.
03. T.P.C.
04. T.R.D.
05. T.O.F.
06. H.M.P.I.D.
07. P.H.O.S. C.P.V.
08. L3 MAGNET
09. ABSORBER
10. TRACKING CHAMBERS
11. MUON FILTER
12. TRIGGER CHAMBERS
13. DIPOLE MAGNET
14. P.M.D.
15. COMPENSATOR MAGNET
16. C.A.S.T.O.R.
Bonding Workshop – CERN 11-12/06/2003 – p.3/26
The TRDetector
Bonding Workshop – CERN 11-12/06/2003 – p.4/26
The TRD in numbers
The ALICE Transition Radiation Detector
has 540 chambers of 12 different types
covers 746 m
area
offers close to 1.2 million readout channels
will be the world’s biggest TRD
Bonding Workshop – CERN 11-12/06/2003 – p.5/26
The TRD readout chamberand pad plane
Bonding Workshop – CERN 11-12/06/2003 – p.6/26
Xsection of a TRD Read Out Chamber
Bonding Workshop – CERN 11-12/06/2003 – p.7/26
ROC and pad plane
ROCs are to big to produce pad planes out of onesingle piece
maximum pad plane manufacturing size :1225 mm x 580 mm
full TRD pad plane is divided into 1512 single pieces
pieces range from 996 mm x 300 mmto 1218 mm x 550 mm
pad plane material :360 thick halogen free FR4,17 Cu on both sides
Bonding Workshop – CERN 11-12/06/2003 – p.8/26
A TRD pad plane
Bonding Workshop – CERN 11-12/06/2003 – p.9/26
The TRD signal cable
Bonding Workshop – CERN 11-12/06/2003 – p.10/26
Requirements
cable connects pad plane to readout board electronics
full TRD has 65664 signal cables
cable should be fixed directly onto the pad plane,avoiding usage of connectors there
big number calls for a reasonably cheap solution
Bonding Workshop – CERN 11-12/06/2003 – p.11/26
Cable design
pad plane side readout board side
bonded connector
Bonding Workshop – CERN 11-12/06/2003 – p.12/26
Cable properties
22 traces
23 mm width
60 mm length
35 thickness
material : capton - copper - capton
bonding gold on both ends
bonding footprint : 6 mm x 0.6 mm pads, gap 0.4 mm
Bonding Workshop – CERN 11-12/06/2003 – p.13/26
Cable bonding tests
Bonding Workshop – CERN 11-12/06/2003 – p.14/26
What is ACF bonding ?
little conductive metal spheres are added to the tape
when curing the tape under pressure and heat, thespheres get pressed into the bonding footprints andthus provide electrical contact
Bonding Workshop – CERN 11-12/06/2003 – p.15/26
ACF before bonding
Bonding Workshop – CERN 11-12/06/2003 – p.16/26
ACF after bonding
Bonding Workshop – CERN 11-12/06/2003 – p.17/26
More ACF bonding
ACF is used in these industrial sectors :
mobile phone manufacturing
automobile industry
LCD production / mobile computers
requires bonding gold on both footprints for goodcontact
selected ACF film for cable bonding tests : 3M 7303
Bonding Workshop – CERN 11-12/06/2003 – p.18/26
Properties of 3M Z-axis adhesive film 7303
adhesive thickness 62,5
silver coated glass spheres, diameter 35
minimum gap between pads 0.25 mm
minimum overlap area 0.8 mm
peel strength 500 g/cm 1 kg per cable
interconnect resistance 0.5 - 0.6
resistance stability 5.0 or better
bonding conditions :
temperature 135
C
pressure 15-18 kg/cm
time 25 sBonding Workshop – CERN 11-12/06/2003 – p.19/26
Bonding step 1 : Tape
Bonding Workshop – CERN 11-12/06/2003 – p.20/26
Bonding step 2 : Align
alignment can be done by hand
Bonding Workshop – CERN 11-12/06/2003 – p.21/26
Bonding step 3 : Bond
Bonding Workshop – CERN 11-12/06/2003 – p.22/26
Bonding test results
trace no
2 4 6 8 10 12 14 16 18 20 22
cable no
12
34
56
78
resi
atan
ce (
Oh
m)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
resistance of cable bonds - board no. 02
Bonding Workshop – CERN 11-12/06/2003 – p.23/26
More bonding test results
Resistances depending on the pressure
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5
Pad number
Res
ista
nce
(Ω)
padplane 2, 112Npadplane 3, 112Npadplane 5, 140Npadplane 7, 150N
Bonding Workshop – CERN 11-12/06/2003 – p.24/26
Results and Conclusions
bond resistance including cable and connectoris 0.55 0.1
U-shaped -distribution due to heat loss on rims
cable bonding is a quick, reliable procedure
pad plane does not deform under bonding heatup to 200
C
poorly connected cables can simply be peeled offand rebonded with another cable after cleaning thefootprint
but : our pad planes are to large to be gold plated
have to solder the cables
Bonding Workshop – CERN 11-12/06/2003 – p.25/26
Thank you very muchfor your attention
Bonding Workshop – CERN 11-12/06/2003 – p.26/26