ACE Electromagnetics Pvt. Ltd Reg. Off.: 61, Bindal Industrial Premises, Sakinaka, Andheri (E), Mumbai – 400 072. Tel.: 022-66453333 / 31 email: [email protected] www.aceelectromagnetics.com CIN:U29308MH2006PTC162739 ACE Detuning Reactors Reduce resonance use ACE-Detuning Reactors General Features & Advantages Applications The increasing use of modern electronics has increased THDi demand from the source which has increased THDv of the source. This nonlinear current influences the network with harmonics, polluting the line. The typical THDv resonates with the shunt power capacitors in PFC panels resulting undesirable effects: Amplification of Harmonics. Over Loading of Capacitors. Overloading of Transmission lines. Over Loading of Transformers. Voltage Distortion. Interference with metering, controls etc. The resonance can be avoided by connecting Detuned reactors in series with power capacitors. Can be operated in high Harmonics environment. High linearity >= 180%. Low dB. Insulation 'H' Class. Easy mounting. Low Watt Loss/Kg. Natural Cooled & Compact. Power Factor Correction Panels. Anti Resonance facility requirements. Line Pollution mitigation systems. Power Loss Management Industries. Efficiency - Saves Energy

Upload: others

Post on 18-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ACE Electromagnetics Pvt. Ltdaceelectromagnetics.com/ACE-detuned-reactor.pdf · ACE Electromagnetics Pvt. Ltd Reg. Off.: 61, Bindal Industrial Premises, Sakinaka, Andheri (E), Mumbai

ACE Electromagnetics Pvt. LtdReg. Off.: 61, Bindal Industrial Premises,

Sakinaka, Andheri (E), Mumbai – 400 072.Tel.: 022-66453333 / 31

email: [email protected]

CIN:U29308MH2006PTC162739

ACEDetuningReactors

Reduce resonance useACE-Detuning Reactors

General Features & Advantages

Applications

The increasing use of modern electronics has increased THDi demand from the source which has increased THDv of the source. This nonlinear current influences the network with harmonics, polluting the line.

The typical THDv resonateswith the shunt power capacitors in PFC panels resulting undesirable effects:Amplification of Harmonics.Over Loading of Capacitors.Overloading of Transmission lines.Over Loading of Transformers.Voltage Distortion.Interference with metering,controls etc.

The resonance can be avoided by connecting Detuned reactors in series with power capacitors.

Can be operated in high Harmonics environment.

High linearity >= 180%.

Low dB.

Insulation 'H' Class.

Easy mounting.

Low Watt Loss/Kg.

Natural Cooled & Compact.

Power Factor Correction Panels.

Anti Resonance facility requirements.

Line Pollution mitigation systems.

Power Loss Management Industries.

Efficiency - Saves Energy