accommodation cabin

5
Accommodation Cabin Modex Accommodation cabins are designed and built to international offshore standards; DNV 2.7-1/2.7-2, NORSOK and ATEX. Cabins are fitted out with furnishing according to client layout and functional requirements. Optional equipment includes automatic transformer control for connection to various power sources, floor heating and backup AirCondition. Specifications Features A60 fire rated Pressurized PLC controlled fire & gas shutdown system Optional sprinkler system Standards DNV 2.7-1 / 2.7-2 / EN12079 NORSOK Z-015 ATEX, IECEx SOLAS A60 Dimensions Standard: 20ft/32ft footprint Dimensions can be customized Application Accommodation cabin for 2-8 men. Camp solution. MWD/LWD Cabin Modex pressurized MWD/LWD cabins are designed and built to international offshore standards; DNV 2.7-1/2.7-2, NORSOK and ATEX. Cabins are insulated to A60, pressurized and fitted out with furnishing according to client layout and functional requirements. Optional equipment includes automatic transformer control for connection to various power sources, floor heating and backup Air Condition. Specifications Features Pressurized if designed for Zone 1 operation

Upload: tamilchelvam-murogayah

Post on 02-Jan-2016

52 views

Category:

Documents


1 download

DESCRIPTION

Accomodation Cabin

TRANSCRIPT

Page 1: Accommodation Cabin

Accommodation CabinModex Accommodation cabins are designed and built to international offshore standards; DNV 2.7-1/2.7-2,

NORSOK and ATEX. Cabins are fitted out with furnishing according to client layout and functional

requirements. Optional equipment includes automatic transformer control for connection to various power

sources, floor heating and backup AirCondition.

SpecificationsFeatures

A60 fire rated

Pressurized

PLC controlled fire & gas shutdown system

Optional sprinkler system

Standards

DNV 2.7-1 / 2.7-2 / EN12079

NORSOK Z-015

ATEX, IECEx

SOLAS A60

Dimensions

Standard: 20ft/32ft footprint

Dimensions can be customized

Application

Accommodation cabin for 2-8 men.

Camp solution.

MWD/LWD CabinModex pressurized MWD/LWD cabins are designed and built to international offshore standards; DNV 2.7-

1/2.7-2, NORSOK and ATEX. Cabins are insulated to A60, pressurized and fitted out with furnishing according

to client layout and functional requirements. Optional equipment includes automatic transformer control for

connection to various power sources, floor heating and backup Air Condition.

SpecificationsFeatures

Pressurized if designed for Zone 1 operation

Non-pressurized if designed for Zone 2 operation.

PLC controlled fire & gas shutdown system

Page 2: Accommodation Cabin

EX Zone 1 rated

Standards

DNV 2.7-1 / 2.7-2 / EN12079

NORSOK Z-015

ATEX, IECEx

SOLAS A60

Dimensions

Standard: 16ft/20ft footprint

Dimensions can be customized

Application

LWD/MWD cabin

Workshop CabinModex Workshop Cabins are designed and built to international offshore standards; DNV 2.7-1/2.7-2, NORSOK

and ATEX.

Workshops for cold work are designed as non pressurized for Zone 2 operation.

Workshops for hot work are pressurized for Zone 1 and 2 operations.

Zone 2 Workshops are available with or without insulation and inside lining. Workshop Cabins can be

customized to client layout and functional requirements. Optional floor heating and Air Condition can be

supplied.

SpecificationsFeatures

Non pressurized cold work workshops for Zone 2 operations.

Pressurized hot work workshops for Zone 1 and 2 operations.

Steel furniture (workbench, shelves and tool racks)

Standards

DNV 2.7-1 / 2.7-2 / EN12079

NORSOK Z-015

ATEX, IECEx

SOLAS A60

Dimensions

Standard: 10ft/20ft footprint

Dimensions can be customized

Application

Workshop for hot or cold work

Laboratory CabinModex laboratory cabins are designed and built to international offshore standards; DNV 2.7-1/2.7-2, NORSOK

and ATEX. Cabins are insulated to A60. Zone 1 rated Cabins are pressurized with fire and gas shut down

system. Zone 2 rated Cabins are non-pressurized and equipped with ATEX Zone 2 EX electric equipment. All

cabins can be fitted out with equipment and furnishing according to client layout and functional

requirements. Optional equipment includes automatic transformer control for connection to various power

sources, floor heating and backup Air Condition.

Specifications

Page 3: Accommodation Cabin

Features

Pressurized if designed for Zone 1 operation

Non-pressurized if designed for Zone 2 operation.

PLC controlled fire & gas shutdown system

Standards

DNV 2.7-1 / 2.7-2 / EN12079

NORSOK Z-015

ATEX, IECEx

SOLAS A60

Dimensions

Standard: 16ft/20ft footprint

Dimensions can be customized

Application

Laboratory cabin

Rental cabin - standard

technical specification

Rental Cabin - Design

& build standards

Available

upgrades &

Options

Designed to meet DNV 2.7-

1/DNV 2.7-2

DNV approved

Custom-outfitting

service

Typical sizes 10/13/16/ 20’ x

8’

ATEX Compliant if

required (Cat 2/3)

Full service

support including

customers’ fleet

cabins

A60 fire rated SOLAS compliant Sink units

Protected with a fully

automatic fire and gas

detection & shutdown system IMO FTP code compliant

Shelving, tool

cabinets &

furniture

Fitted with heating,

ventilation & air conditioning

(+45 deg C)

Structural design:

BSEN12079

Ex rated

telephones

Automatic fire dampers with

local indication (fail safe)

Structural design: DNV

2.7-1

Flat screen

monitors with

USB/VGA

connectors

Page 4: Accommodation Cabin

Quick connections for mains

power and remote alarms

Electrical design: DNV

2.7-2

CD players, iPhone

docking stations

Fan deployable for remote

installation in a safe area

Can also be approved by

ABS / LRS / BV, etc to suit

customer requirements

19” equipment

racks

240v power outlets Zone 1 and Zone 2 Fume hoods

110v power outlets

(stabilised)

NORSOK Z-015 cabins

available

CAT 5 Data/telephone points

Stackable 4 high on fixed or 3

high on floating installations

using standard ISO

connectors

Load tested and supplied with

fully certified lifting gear

Certified PA Speaker

A60 window fitted as

standard

A60 emergency escape hatch

Equipped with fire

extinguisher