absolute automation inc. - insidecover · 2014-03-13 · part 68: the sensaphone ® model 1108...

110
Model 1108 User’s Manual version 1.03 Phonetics, Inc. Phonetics, Inc. Phonetics, Inc. Phonetics, Inc. Phonetics, Inc.

Upload: others

Post on 30-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Model 1108

User’s Manual

version 1.03

Phonetics, Inc.Phonetics, Inc.Phonetics, Inc.Phonetics, Inc.Phonetics, Inc.

Page 2: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

Every effort has been made to ensure that the information in thisdocument is complete, accurate and up-to-date. Phonetics, Inc.assumes no responsibility for the results of errors beyond its control.Phonetics, Inc. also cannot guarantee that changes in equipmentmade by other manufacturers, and referred to in this manual, will notaffect the applicability of the information in this manual.

© 1998 by Phonetics, Inc.

Revised Edition, version 1.03, September, 2000

Written and produced by Phonetics, Inc.

Sensaphone® is a registered trademark of Phonetics, Inc.

Touch-Tone™ is a registered trademark of AT&T.

Page 3: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

iii

IMPORTANT SAFETY INSTRUCTIONS

Your Model 1108 has been carefully designed to give you yearsof safe, reliable performance. As with all electrical equipment,however, there are a few basic precautions you should take toavoid hurting yourself or damaging the unit:

• Read the installation and operating instructions in thismanual carefully. Be sure to save it for future reference.

• Read and follow all warning and instruction labels onthe product itself.

• To protect the Model 1108 from overheating, make sureall openings on the unit are not blocked. Do not place onor near a heat source, such as a radiator or heat register.

• Do not use your Model 1108 near water, or spill liquidof any kind into it.

• Be certain that your power source matches the ratinglisted on the AC power transformer. If you’re not sure ofthe type of power supply to your facility, consult yourdealer or local power company.

• Do not allow anything to rest on the power cord. Do notlocate this product where the cord will be abused bypersons walking on it.

• Do not overload wall outlets and extension cords, as thiscan result in the risk of fire or electric shock.

• Never push objects of any kind into this product throughventilation holes as they may touch dangerous voltagepoints or short out parts that could result in a risk of fireor electric shock.

• To reduce the risk of electric shock, do not disassemblethis product, but return it to Phonetics CustomerService, or other approved repair facility, when anyservice or repair work is required. Opening or removingcovers may expose you to dangerous voltages or otherrisks. Incorrect reassembly can cause electric shockwhen the unit is subsequently used.

Page 4: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

iv

• If anything happens that indicates that your Model 1108is not working properly or has been damaged, unplug itimmediately and follow the procedures in Appendix Cfor having it serviced. Return the unit for servicingunder the following conditions:

1. The power cord or plug is frayed or damaged.

2. Liquid has been spilled into the product or it has beenexposed to water.

3. The unit has been dropped, or the cabinet is damaged.

4. The unit doesn’t function normally when you’refollowing the operating instructions.

• Avoid using a telephone (other than a cordless type)during an electrical storm. There may be a remote riskof electric shock from lightning.

• Do not use the telephone to report a gas leak in thevicinity of the leak.

CAUTION

To Reduce the Risk of Fire or Injury to Persons, Read andFollow these Instructions:

1. Use only the following type and size batteries:Alkaline, size D.

2. Do not dispose of the batteries in a fire. The cell mayexplode. Check with local codes for possible specialdisposal instructions.

3. Do not open or mutilate the batteries. Released electrolyteis corrosive and may cause damage to the eyes or skin. Itmay be toxic if swallowed.

4. Exercise care in handling batteries in order not to shortthe battery with conducting materials such as rings,bracelets, and keys. The battery or conductor mayoverheat and cause burns.

5. Do not mix old and new batteries in this product.

Page 5: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

v

FCC Requirements

Part 68: The Sensaphone® Model 1108 complies with Part 68of the FCC rules. On the back of the unit there is a label thatcontains, among other information, the FCC RegistrationNumber and the Ringer Equivalence Number (REN) for thisequipment. You must, upon request, provide this information toyour local telephone company.

The REN is useful to determine the quantity of devices that youmay connect to your telephone line and still have all of thosedevices ring when your telephone number is called. In most,but not all areas, the sum of the REN’s of all devices connectedto one line should not exceed five (5.0). To be certain of thenumber of devices that you may connect to your line, you maywant to contact your local telephone company to determine themaximum REN for your calling area.

This equipment may not be used on coin service provided bythe telephone company. Connection to party lines is subject tostate tariffs.

Should the Model 1108 cause harm to the telephone network,the telephone company may discontinue your service tempo-rarily. If possible, they will notify you in advance. But ifadvance notice isn’t practical, the telephone company maytemporarily discontinue service without notice and you will benotified as soon as possible. You will be informed of your rightto file a complaint with the FCC. The telephone company maymake changes in its facilities, equipment, operations, orprocedures where such action is reasonably required in theoperation of its business and is not inconsistent with the rulesand regulations of the FCC that could affect the proper func-tioning of your equipment. If they do, you will be notified inadvance to give you an opportunity to maintain uninterruptedtelephone service.

Page 6: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

vi

The telephone company may ask that you disconnect thisequipment from the network until the problem has beencorrected or until you are sure that the equipment is notmalfunctioning.

Part 15: This equipment has been tested and found to complywith the limits for a Class B digital device, pursuant to Part 15of the FCC Rules. These limits a designed to provide reason-able protection against harmful interference in a residentialinstallation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guaranteethat interference will not occur in a particular installation. Ifthis equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correctthe interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and thereceiver.

• Connect the equipment into an outlet on a circuitdifferent from that to which the receiver is connected.

• Consult the dealer or an experienced radio/televisiontechnician for help.

Page 7: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

vii

Canadian Department of Communications Statement

Notice: The Canadian Department of Communications labelidentifies certified equipment. This certification means that theequipment meets certain telecommunications network protec-tive operational and safety requirements. The Department doesnot guarantee the equipment will operate to the user’s satisfac-tion.

Before installing this equipment, users should ensure that it ispermissible to be connected to the facilities of the localtelecommunications company. The equipment must also beinstalled using an acceptable method of connection. In somecases, where the company’s inside wiring is associated with asingle line, individual service may be extended by means of acertified connector assembly (telephone extension cord). Thecustomer should be aware that compliance with the aboveconditions may not prevent degradation of service in somesituations.

Repairs to certified equipment should be made by an autho-rized Canadian maintenance facility designated by the supplier.Any repairs or alterations made by the user to this equipment,or equipment malfunctions, may give the telecommunicationscompany cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electricalground connections of the power utility telephone lines andinternal metallic water pipe system, if present, are connectedtogether. This precaution may be particularly important in ruralareas.

CAUTION: Users should not attempt to make such connectionsthemselves, but should contact the appropriate electric inspec-tion authority, or electrician, as appropriate.

The Load Number (LN) assigned to each terminal devicedenotes the percentage of the total load to be connected to atelephone loop which is used by the device to prevent overload-ing. The termination on loop may consist of any combination ofdevices subject only to the requirement that the total of theLoad Numbers of all the devices does not exceed 100. For theSensaphone® Model 1108, the Load Number is 8.

Page 8: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

viii

Page 9: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 1: Introduction

ix

Model 1108Table of Contents

version 1.03

Important Safety Instructions ..................................... iiiFCC Requirements .............................................................. vCanadian Department of Communications Statement ......... vi

Chapter 1: Introduction................................................. 1Technical Support .................................................... 2

Chapter 2: Installation................................................... 32.1 Operating Environment ........................................ 3

2.2 Mounting ................................................................ 3

2.3 Power Surge Protection ........................................ 4

2.4 Power Supply and Battery Backup ...................... 4

2.5 Starting the Model 1108 ........................................ 5

2.6 Run Mode and Standby Mode .............................. 5

2.7 Telephone Line ...................................................... 6

2.8 The Microphone..................................................... 7

2.9 Alert Inputs ............................................................ 8

2.10 Installing the Sensor ............................................. 9

2.11 Multiple Sensors ................................................. 11

2.12 Outdoor Wiring .................................................... 12

2.13 Disconnecting the Model 1108 forStorage or Seasonal Use. ................................... 13

Chapter 3: Quick Start ................................................ 153.1 The Local Keypad................................................ 15

3.2 Preparation for Programming ............................ 16

3.3 Quick-Start Programming Steps ........................ 16Step 1: Set Configuration of Inputs ...................... 16Step 2: Set the ID Number ................................... 17Step 3: Set Dial-Out Telephone Numbers ............ 18Step 4: Set Temperature Limits ............................ 19

3.4 Summary of the Alarm Dial-Out Process .......... 21

Page 10: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

x

Chapter 4: Communications Programming .............. 234.1 The Unit ID Number ............................................. 234.1.1 Programming the ID Number ................................ 244.1.2 Interrogating the ID Number .................................. 24

4.2 Dial-out Telephone Numbers .............................. 254.2.1 Programming Dial-out Telephone Numbers .......... 254.2.2 Interrogating a Dial-out Telephone Number .......... 264.2.3 Erasing a Telephone Number ................................ 26

4.3 Tone or Pulse Dialing .......................................... 27

4.4 Special Dialing ..................................................... 274.4.1 Special Dialing Keys ............................................. 284.4.2 Incorporating a Pause ........................................... 294.4.3 Incorporating a Pound (#) or Asterisk (*) ............... 304.4.4 Special Dialing to a Beeper or Pager .................... 31

4.5 Rings Until Answer ............................................. 334.5.1 Programming Rings Until Answer ......................... 334.5.2 Interrogating Rings Until Answer ........................... 34

4.6 TAD (Telephone Answering Device) ................. 344.6.1 TAD Enable/Disable .............................................. 354.6.2 Using the TAD feature ........................................... 354.6.3 No TAD In Use ...................................................... 36

4.7 Listen-in Time ...................................................... 374.7.1 Programming the Listen-in Time ........................... 374.7.2 Interrogating the Listen-in Time ............................. 38

4.8 Call Delay ............................................................. 384.8.1 Programming the Call Delay ................................. 384.8.2 Interrogating Call Delay ......................................... 39

4.9 Local Voice Mute ................................................. 404.9.1 Enable/Disable Local Voice Mute .......................... 40

4.10 Voice Repetitions ................................................ 404.10.1 Programming Voice Repetitions ............................ 414.10.2 Interrogating Voice Repetitions ............................. 41

4.11 Intercall Time ....................................................... 424.11.1 Programming Intercall Time .................................. 424.11.2 Interrogating Intercall Time .................................... 43

Page 11: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 1: Introduction

xi

4.12 Maximum Number of Calls (Max Calls) ............. 434.12.1 Programming Max Calls ........................................ 444.12.2 Interrogating Max Calls ......................................... 45

4.13 The Clock ............................................................. 454.13.1 Setting the Clock ................................................... 454.13.2 Interrogating for the Current Time ......................... 46

4.14 The Security Code ............................................... 474.14.1 Locking the Keypad ............................................... 474.14.2 Unlocking the Keypad ........................................... 48

Chapter 5: Alarm Programming ................................. 495.1 Input Configuration ............................................. 495.1.1 Programming Input Configuration ......................... 505.1.2 Verifying Input Configuration ................................. 51

5.2 Enable/Disable Inputs ......................................... 515.2.1 Changing Enabled/Disabled Input Status ............. 525.2.2 Verifying Enabled/Disabled Input Status ............... 52

5.3 Input Recognition Time....................................... 535.3.1 Programming Input Recognition Time ................... 535.3.2 Interrogating Input Recognition Time ................... 54

5.4 Establishing High and LowTemperature Limits ............................................. 55

5.4.1 Programming Temperature Limitsfor a Selected Input ............................................... 55

5.4.2 Disabling Alarm Response to High orLow Temperature .................................................. 56

5.4.3 Interrogating High and Low Temperature Limits ... 57

5.5 Temperature Scale .............................................. 57

5.6 Temperature Calibration ..................................... 585.6.1 Programming Temperature Calibration ................. 585.6.2 Interrogating Temperature Calibration ................... 60

5.7 Obtaining Current Temperature ......................... 60

5.8 AC Power Monitoring Enable/Disable ............... 615.8.1 Enabling/Disabling the AC Power Alarm ............... 61

5.9 AC Power Failure Recognition Time .................. 615.9.1 Programming Power Failure Recognition Time..... 62

Page 12: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

xii

5.9.2 Interrogating Power Failure Recognition Time ...... 63

5.10 Sound Alarm Monitoring .................................... 635.10.1 Programming Sound Alarm Sensitivity .................. 645.10.2 Interrogating Sound Sensitivity ............................. 645.10.3 Programming High Sound Alarm

Recognition Time .................................................. 65

5.11 High Sound Alarm Enable/Disable .................... 665.11.1 Changing Enabled/Disabled High Sound Alarm.... 66

5.12 Exit Delay ............................................................. 66

Chapter 6: Acknowledgment, Status Report, andRemote Access ................................................. 696.1 Alarm Acknowledgment ..................................... 696.1.1 Local Acknowledgment ......................................... 696.1.2 Touch-Tone™ Acknowledgment ............................ 696.1.3 Callback Acknowledgment .................................... 70

6.2 Status Report ....................................................... 716.2.1 Example: Status Report, No Alarms ..................... 726.2.2 Example: Status Report, Existing Alarms ............. 736.2.3 Example: Status Report, Disabled Inputs ............ 746.2.4 Battery Condition ................................................... 756.2.5 Remote Access by Touch-Tone™ Telephone ........ 75

Chapter 7: Operation .................................................. 797.1 Alarm Detection, Dial-out and

Acknowledgment ................................................. 79

7.2 Example: A Dial-out Telephone Call .................. 84

Appendix A: Troubleshooting..................................... 85

Appendix B: Checking for Proper Operation ............ 93

Appendix C: Accessories ........................................... 95

Appendix D: Returning the Unit for Repair ............... 97

Product Warranty......................................................... 98

Page 13: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 1: Introduction

1

Chapter 1: Introduction

The Sensaphone® Model 1108 is a fully-programmable,environmental monitoring system that offers extensive on-siteand remote monitoring capability to small businesses, privatehomes, farms, greenhouses, computer rooms, and remotefacilities. Designed for desktop or wall mounting, theModel 1108 is simple to install, program and operate; nochanges to standard electrical or telephone service are required.Connected to a telephone line, it will respond to an alarm bydialing up to eight separate telephone numbers. When the callis answered, an “Alert Condition” message is delivered indigitized speech.

The Model 1108 features built-in sensors to monitor a varietyof conditions:

• High sound level

• AC electric power failure

• Battery backup

• Temperature*

*(Note: While technically not a “built-in” sensor,temperature is factory installed on input 1, and if leftinstalled will limit your additional inputs as listed belowto 7.)

Equipped with 8 alert inputs, additional sensors* can be addedfor extended monitoring:

• Intrusion or unauthorized entry

• Water leaks and seepage

• Temperature

• Humidity

• Equipment operation

• Many other conditions that may require uniquemonitoring solutions

*Refer to Appendix B for information on additional sensors(available separately from Phonetics) that are best suited toyour application.

Page 14: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

2

The status of each monitored condition is readily obtained atthe unit's installation site or remotely, by telephone. At theclose of every Status Report, time is provided for listening toon-site sounds.

To ensure reliable operation, the Model 1108 features powerbackup capability; in the event of AC power failure,six D-cell batteries (not included) will continue to power theunit for approximately 24 hours.

This manual comprises the instructions and commands forinstalling and operating the Model 1108. The Quick Startchapter is included to speed understanding of programming andoperation. Communication and Alarm Programming chaptersdemonstrate step-by-step methods for utilizing the full range ofavailable features. The Troubleshooting chapter providesassistance in the event that problems are encountered.

Phonetics, Inc.

Page 15: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 2: Installation

3

Chapter 2: Installation

Correctly installing the Model 1108 will ensure properfunctioning of the unit. Please read the entire chapter beforestarting the installation process.

Within the packaging will be a Warranty Registration Card.Please take the time to fill this out and mail. The One YearLimited Warranty is explained in the back of this manual.

2.1 Operating Environment

The Model 1108 should be installed and operated in an areathat provides space for wiring sensors to the screw terminals,near an AC power source and telephone line. Operatingtemperature ranges from 32° Fahrenheit (0° Celsius) to +120°Fahrenheit (+49° Celsius).

NOTE

The Model 1108 is a sensitive electronic device.Do not install the Model 1108 near strongelectrostatic, electromagnetic or radioactivefields. Do not expose to fumes or corrosivevapors.

2.2 Mounting

Flat Mount: Place the Model 1108 on top of a desk or otherhorizontal surface. Wall Mount: Mount on a wall with twoscrews using the keyholes on the back panel of the unit. Placethe screws or bolts 313/16" apart at the desired height from thefloor. Hook the unit over the screws and toward the floor. Referto Figure 2-1.

Page 16: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

4

3 13/16"

Figure 2-1. Wall Mount

2.3 Power Surge Protection

The Model 1108 can be damaged by power surges and light-ning through the telephone line and the 120 VAC power supply.Although the Model 1108 has built-in surge protection, werecommend that ad ditional pr otection be obtained f or theunit and f or an y electr onic equipment that is attac hed toyour power supply and telephone lines. Power surgeprotection is especiall y impor tant if y ou live in a lightning-prone area. The ISOTEL Surge Protector Model IB-4 isavailable through Phonetics. See Appendix B.

2.4 Power Supply and Battery Backup

The Model 1108 is provided with an AC power transformerthat will plug into any standard 120 VAC outlet and a batterybackup (batteries not included) that enables the unit to continuefunctioning if AC power is removed (due to electric powerdisruption or failure). The Model 1108 uses six, D-cell alkalinebatteries. Do not use rechargeable nicad batteries.

NOTE

Be sure that the AC transformer is plugged intoan outlet before installing batteries.

To install the batteries, open the battery compartment hatchlocated underneath the unit, align batteries according to thediagram shown in Figure 2-2, and replace the hatch.

Page 17: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 2: Installation

5

- - -

---

+ + +

+++

Figure 2-2. Battery Installation

2.5 Starting the Model 1108

When the AC power transformer is first plugged into theelectrical outlet, the Model 1108 automatically starts in RUNmode. The red LED light will begin to glow. The unit willrespond with“Hello, this is Sensaphone® 1108.”

2.6 Run Mode and Standby Mode

Pressing the RUN/STANDBY key on the Model 1108 keypadwill alternately activate or deactivate the unit. If the unit isactivated and in RUN mode, the red LED (small red light on theupper right of the unit's front panel) glows steadily. InSTANDBY mode, the red LED goes out, but will blink everyfew seconds to indicate that power is still supplied to the unit.

In RUN mode, the Model 1108 is able to receive incoming callsand to automatically dial out in the event of an alarm on one ofthe monitored conditions. To enter STANDBY mode, pressRUN/STANDBY.

As soon as the Model 1108 enters STANDBY mode, itresponds with “Have a good day.” The red light immediatelygoes out and then resumes with a blink every few seconds.While in STANDBY mode, all functions are disabled, butprogrammed memory is preserved. Upon exiting STANDBYmode, any currently existing alert conditions will be announced.

Page 18: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

6

NOTE

STANDBY mode is not equivalent to “poweroff”—an electrical source, such as the 120 VAC,or the battery backup, continues to provide fullpower to the unit. If the unit is placed inSTANDBY mode, unplugged from the 120 VACoutlet, and placed in storage, the batteries willcontinue to power the Model 1108, discharginguntil they fail. Consequently, batteries shouldalways be removed from the unit followingdisconnection from any 120 VAC outlet, prior tostorage.

Press the RUN/STANDBY key again to return to RUN mode.

RUNSTANDBY

Figure 2-3. The RUN/STANDBY Key

2.7 Telephone Line

The Model 1108 will operate with all standard telephonesystems that accept pulse or tone dialing. The Model 1108cannot be used on an extension line to dial its own telephonenumber. Also, it may not be installed on a party line or paytelephone line.

Certain private telephone systems and public switchingequipment may not accept the Model 1108 dialing or maygenerate an unacceptable ring signal. In those cases, a dedi-cated line may be required. Consult the supplier of yourtelephone system if you encounter problems.

If you do not have a modular telephone extension at theModel 1108’s location, you must contact your local telephonecompany to have one installed (there is a charge for thisservice). If you have four-pin jacks, adapters are available toconvert them to the modular plugs. Contact your localtelephone company or electronics parts store.

Page 19: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 2: Installation

7

CAUTION

Never install telephone wiring during a lightningstorm. Never install telephone jacks in wetlocations unless the jack is specifically designedfor wet locations. Never touch uninsulatedtelephone wires or terminals unless the telephoneline has been disconnected at the networkinterface. Use caution when installing ormodifying telephone lines.

To install the telephone line, plug the modular telephone jackprovided into any standard RJ11 phone outlet. Refer toFigure 2-4.

2 3 4 5 6 7 81 GND GND GNDGND

AC Power Transformer(plug into 110 VAC outlet)

RJ11 Outlet(for modular telephone jack)

Modular Telephone Jack(plug into RJ11 outlet)

Female Telephone Jack (connect telephone here)

Figure 2-4. Installing the Telephone Line

On the back of the Model 1108 is a female telephone jack.This is provided so that a telephone or other answering devicemay be used on the same line as the unit. It is not necessary tohook up a telephone for the Model 1108 to operate.

2.8 The Microphone

The Model 1108 is provided with a built-in microphone whichis used to monitor high sound levels produced near the installa-tion site. The sensitivity of the microphone is configurable andwill detect a continuous as well as a beeping alarm.

Other programming options that apply to the microphoneinclude setting the length of time before a high sound causes analarm.

If this sound level exists for 8 consecutive seconds (default) orfor the programmed length of time, the Model 1108 will dialout with an alarm message.

Page 20: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

8

NOTE

The proximity of the audible alarm to themicrophone is extremely important.Normally, the Model 1108 and the audible alarmmust be in the same room. The maximumdistance can vary considerably depending on thealarm, the acoustics, and the size of the room.

During an alarm dial-out, the microphone allows four-secondintervals to listen-in to sounds at the Model 1108’s location.

When calling for a Status Report, the microphone permitslistening to on-site sounds for a programmed time interval.

2.9 Alert Inputs

The Model 1108 can monitor up to 8 inputs (represented by thenumbered terminal screws shown in Figure 2-5, below). Twoinput terminals share the same ground.

2 3 4 5 6 7 81 GND GND GNDGND

Figure 2-5. Alert Inputs

Inputs are configured as either dry contact or temperature.An input configured as dry contact can be used with anynormally open (N.O.) or normally closed (N.C.) device.“Open” refers to an opened circuit path; if conditions cause thecircuit to close, an alert condition occurs. “Closed” refers to acontinuous circuit path; if a closed circuit is opened, an alertcondition occurs. The Model 1108 determines the way inputsare configured by the type of sensor connected to each alertinput (refer to Chapter 5, Section 5.1).

Page 21: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 2: Installation

9

An input configured as “temperature” is designed to evaluate arange of settings. The Model 1108 will read the temperature atthe sensor’s location and compare that value to programmedhigh and low temperature limits. Temperature inputs must beused with Phonetics Remote Temperature Sensor.

NOTE

Before wiring, it is advisable to disable theinputs to prevent accidentally tripping an alarm.Refer to Chapter 5, Section 5.2.

2.10 Installing the Sensor

After you have selected the sensor, loosen the screw of the alertinput and its corresponding ground. Two wire leads are used toconnect any monitoring sensor. Fasten one lead to the num-bered screw and the other lead to GND. Tighten both screws. Ifthe input was not disabled, the Model 1108 may recite its“Alert Condition Exists” message as you connect the sensor. Ifit does, just press any key to stop. Re-enable the input afterwiring. Refer to Figures 2-6 and 2-7 for connecting a sensor toan alert input.

2 3 4 5 6 7 81 GND GND GNDGND

Sensor wired to Alert Input 5

Figure 2-6. Sensor Connected to an Alert Input

Page 22: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

10

Any sensor can be attached to the Model 1108 using 22-gaugewire. The sensor can be several hundred feet from the unit, aslong as the total resistance of the circuit is not greater than 50ohms. Use wire appropriate for the application.

2 3 4 5 6 7 81 GND GND GNDGND

Sensor wired to Alert Input 3

Sensor wired to Alert Input 4

Figure 2-7. Two Sensors Wired to Adjacent InputsShare the Same Ground Terminal Screw

NOTE

Do not use sensors, switches, or relays thatsupply any voltage or current to the Model 1108.Be aware of proximity to other electrical wires orcomponents when placing wires that lead fromthe sensors to the unit. Avoid running the wiresnear electrical devices that use high voltage orcurrent, such as motors, heavy machinery, etc.This voltage may be inductively coupled into thesensor wiring and could result in damage to thethe Model 1108’s circuitry. Try to place wires atleast 6 inches from other electrical wiring ordevices.

Page 23: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 2: Installation

11

2.11 Multiple Sensors

The Model 1108 may have more than one sensor connected tothe same alert input, as long as the normal condition for eachsensor on the same alert input is identical (either all N.O. or allN.C.). However, only one remote temperature sensor can beused on each input.

When wiring several normally closed sensors on one input,they must be connected in series. Connect one lead from thefirst sensor to the numbered screw of the alert input. Next, takethe other lead from the first sensor and connect it to one leadfrom the next sensor. Continue connecting sensors end-to-enduntil you have connected all of your sensors. Take the secondlead from the last sensor and connect it to the ground screw onthe Model 1108. See Figure 2-8. Multiple N.C. sensors aretypically magnetic reed switches to monitor the security ofwindows and doors.

~~ ~~

Multiple normally-closed sensors wired in series. (Example shown using Input 3.)

Alert condition occurs when a switch is opened.

2 3 4 5 6 7 81 GND GND GNDGND

Figure 2-8. Multiple Normally Closed Sensors

To wire several normally open sensors to one alert input,connect them in parallel. To do this, take one lead from eachsensor and attach it to the numbered terminal. Then, take thesecond lead from each sensor and attach each to the corre-sponding ground screw. Refer to Figure 2-9.

Page 24: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

12

Example with multiple sensors connected to Input 5. Alert condition occurs when a normally open switch closes.

2 3 4 5 6 7 81 GND GND GNDGND

Figure 2-9. Multiple Normally Open Sensors

2.12 Outdoor Wiring

When wiring sensors outdoors, DO NOT allow exposed wiresto run freely in open air; under such conditions, the Model1108 is susceptible to serious damage during a lightning storm.Depending upon the distance outdoor wiring must travel,consideration should be given to use of shielded wire inside ametal conduit. Both shield and conduit should be connected toearth ground. This prevents stray voltage from entering theunit.

sensor

Model 1108

Figure 2-10. Potential Sensor Damage from Stray Electrical Noise

Page 25: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 2: Installation

13

2.13 Disconnecting the Model 1108 for Storage orSeasonal Use.

If you plan to employ the Model 1108 as a seasonal “watch-dog” for a few months during the year, you m ust disconnectall wires fr om the unit completel y to a void dama ge to thecircuitry when the unit is not in use . If the unit is unpluggedbut left in place with all the sensors still connected, the wiresact as antennae that draw in any stray “electrical noise” fromsuch devices as fans, blowers, microwaves, etc.

Additionally, it is important to remove the batteries, or theywill discharge until they fail.

Preserve your Model 1108 during the off-season, orwhen not in use:

• Remove the sensor wires at the screw terminals

• Remove the batteries

• Unplug the unit and store in a safe place

Page 26: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

14

NOTES

Page 27: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 3: Quick Start

15

Chapter 3: Quick Start

This section presents a useful guide for first-time programmingof the Model 1108. Follow instructions for installation beforeattempting to program the Model 1108. Refer toChapter 2: Installation.

3.1 The Local Keypad

Programming is accomplished using the local keypad (shownbelow, Figure 3-1). Notice that a single key has severalfunctions assigned to it; programming results are determinedby the order in which keys are pressed.

Individual keystrokes are illustrated to show programmingsteps in the correct order. If you make a mistake by entering thewrong key, do not press another key until you hear the message“Error 1.” Then, start over with the first key in theprogramming sequence.

CODEMUTE

TEMPF /C

SET#

WHAT IS*

SENSORON/OFF

ENTERTONE

PM

PHONE NUMBER

RING/TADPAUSE

AM

STATUSCONFIGURE

RUNSTANDBY

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

Figure 3-1. The Model 1108 Keypad

Page 28: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

16

3.2 Preparation for Programming

Read complete instructions in Chapter 2: Installation, and makesure to follow these steps first:

1. Plug the AC adaptor into the 120 VAC outlet.

2. Install the batteries.

3. Connect the Model 1108 to a telephone line.

When these steps are completed, the Model 1108 is fullyoperational and able to monitor temperature, high sound,AC power failure and battery backup condition; it can also becalled on the telephone for a Status Report or used for listeningto on-site sounds from any remote location. Now, the unit isready for programming.

3.3 Quick-Start Programming Steps

Step 1: Set Configuration of Inputs

The Model 1108 will scan the 8 external inputs and determineif they are N.O. (normally open), N.C. (normally closed), orTemperature. If external sensors are added, make sure they arein their normal positions before proceeding—refer toChapter 5, Section 5.1.

1. Press STANDBY to place the Model 1108 in Standbymode.

RUNSTANDBY

2. If you have external sensors available, wire the sensors tothe inputs on the back of the Model 1108 (see Chapter 2,Section 2.10). Otherwise, skip this step and move tostep 3.

3. Press RUN. The red light glows when the Model 1108returns to Run mode.

RUNSTANDBY

Page 29: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 3: Quick Start

17

4. Press SET.

SET#

5. Press CONFIGURE.

STATUSCONFIGURE

6. The Model 1108 will audibly recite the new configurationfor each of the eight inputs, responding with “OK,” if itdetects N.O. (normally open), “beep-OK,” if it detectsN.C (normally closed) or “Temperature,” if it detectstemperature (regardless of whether all the inputs haveattached sensors or not). If an input is unused, it is treatedas normally open.

Step 2: Set the ID Number

It is recommended that you set the ID number to reflect thetelephone number on which the Model 1108 is installed.

1. Press SET.

SET#

2. Press ID NUMBER.

0ID NUMBER

POWER

3. Using the number keys, enter the digits (up to 16 arepermitted) for the ID number. The Model 1108 will recitethe digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

Page 30: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

18

4. Press ENTER. The 1108 will respond: “Enter.”

ENTERTONE

PM

Step 3: Set Dial-Out Telephone Numbers

To program dial-out telephone numbers:

1. Press SET.

SET#

2. Press PHONE NUMBER.

PHONE NUMBER

3. Select which telephone number to program. Press anyunassigned number key (from 1 to 8) to represent the newtelephone number entry. Model 1108 will respond: “Enternumber.”

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

4. Enter the complete telephone number using the numberkeys. The Model 1108 will recite the digits as they arepressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press ENTER. The unit will respond: “Enter.”

ENTERTONE

PM

6. Repeat above procedure to program up to eight separatetelephone numbers.

Page 31: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 3: Quick Start

19

Step 4: Set Temperature Limits

High and low temperature limits can be separately programmedfor each input that is configured as temperature. Limits canrange from –20° to +150° Fahrenheit, or from –30° to 65°

Celsius. Default settings are: 10° F for low temperature and100° F for high temperature. Do not set temperature limits tooclose to normal room temperature, since minor fluctuationscould result in frequent and unnecessary alarm dialouts.

1. Press SET.

SET#

2. Press TEMP LIMITS.

TEMP LIMITS

5

3. From the number keys, press a number (from 1 to 8) thatcorresponds to the temperature input being programmed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

The Model 1108 responds: “Enter low temperaturelimit.”

4. Using the number keys, enter a value for low temperaturelimit. The Model 1108 will recite the digits as they arepressed. If a negative number is required, first pressPAUSE, then enter the number.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press ENTER.

ENTERTONE

PM

Page 32: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

20

The Model 1108 responds: “Enter high temperaturelimit.”

6. Using the number keys, enter the value for hightemperature limit. The Model 1108 will recite the digits asthey are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

7. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

This concludes minimum programming to achieve normaloperation of the Model 1108. In additon to the programmingjust accomplished, default settings for many more features takeeffect when the unit is first powered. You will be able toreprogram most of these factory-set defaults to suit yourapplication.

For a complete explanation of each feature (with illustrations ofkeystrokes), refer to Chapter 4: Communications Programmingand Chapter 5: Alarm Programming.

To gain a basic understanding of how the alarm dial-out featureworks, refer to this chapter, Section 3-4. For extended informa-tion regarding dial-out and related programmable parameters,refer to Chapter 7: Operation.

Page 33: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 3: Quick Start

21

Programmable Feature

• Recognition Time

This is the programmedwaiting period to determine ifan alert condition has persistedlong enough to be considered avalid alarm. If the sensorreturns to normal withinrecognition time, then noalarm will occur.

• Call Delay

This is the programmedwaiting period, before the firsttelephone number is called, toreport an alarm.

• Intercall Time

This is the programmedwaiting period, in betweensequential dialing of telephonenumbers, to report an alarm.

• Max Calls

This is the total number oftelephone calls that will bedialed in response to any validalarm. Telephone numbers aredialed sequentially, andcontinue to cycle until themaximum number of calls isreached. If no acknowledg-ment occurs, then at thecompletion of Max Calls, allalarms are automaticallyacknowledged.

Action—Response

1. THE Model 1108 DETECTSAN ALERT CONDITION

An alert condition is not the same as avalid alarm—the condition mustcontinue for the programmed timeperiod, or Recognition Time, before it isrecognized as a valid alarm.

2. A VALID ALARM IS CONFIRMED

An audible, on-site alarm messagebegins and continues until the alarm isacknowledged. (If the Mute feature isturned on, there is no on-site message.)Call Delay is activated.

3. DIAL-OUT BEGINS

Dial-out begins by calling telephonenumber 1 to report an alarm.If there is no acknowledgment, theModel 1108 waits the programmedIntercall Time before dialing subse-quent telephone numbers. Dial-outcontinues in this manner, cyclingthrough the remaining telephonenumbers, for the programmed MaxCalls.

4. THE ALARM ISACKNOWLEDGED

When the alarm is acknowledged, thedial-out process is cancelled and theaudible, on-site alarm message stops.

3.4 Summary of the Alarm Dial-Out Process

Page 34: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

22

NOTES

Page 35: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

23

Chapter 4: Communications Programming

This chapter explains the keypad commands forcommunications programming of the Model 1108,including interrogation and resetting of the following:

• The Unit ID Number

• Dial-out Telephone Numbers

• Tone or Pulse Dialing

• Special Dialing with Pagers, Beepers and AccessNumbers.

• Rings Until Answer and Telephone Answering DeviceCompatibility

• Listen-in Time

• Call Delay

• Local Voice Mute

• Voice Repetitions

• Intercall Time

• Maximum Number of Calls

• The Clock

• Security Code

4.1 The Unit ID Number

The Unit ID Number is the identification number of theModel 1108. This number may be the same as the telephonenumber where the unit is installed, or it may be designatedusing any number that best suits your application.

The purpose of the Unit ID Number is to immediately providethe source of any alarm, especially when using multipleModel 1108 units in a complex monitoring system. Whenthe Model 1108 is called from a remote location, it alwaysbegins its message with the identification number:“Hello, this is telephone number (Unit ID Number).”

Page 36: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

24

4.1.1 Programming the ID Number

To program the ID Number:

1. Press SET.

SET#

2. Press ID NUMBER.

0ID NUMBER

POWER

3. Using the number keys, enter up to 16 digits for the IDnumber. The Model 1108 will recite the digits as they arepressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

4. Press ENTER. The Model 1108 will respond: “Enter.”

ENTERTONE

PM

4.1.2 Interrogating the ID Number

To interrogate the ID numbers:

1. Press WHAT IS.

WHAT IS*

2. Press ID NUMBER. The Model 1108 will recite the UnitID Number programmed.

0ID NUMBER

POWER

Page 37: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

25

4.2 Dial-out Telephone Numbers

The Model 1108 can store up to eight 32-digit phone numbers.These are the numbers that will be called during dial-out.In the event of an alarm, the numbers are dialed sequentially,1 through 8. Begin programming the first telephone number byassigning it to the key labeled with the number 1 on thekeypad, and continue to assign any other telephone numbers innumerical order. A pause, pound or asterisk can be added to anindividual phone number to access different phone and beepersystems. See Special Dialing, Section 4.4.

4.2.1 Programming Dial-out Telephone Numbers

To program dial-out telephone numbers:

1. Press SET.

SET#

2. Press PHONE NUMBER.

PHONE NUMBER

3. Select which telephone number to program. Press anyunassigned number key (from 1 to 8) to represent the newtelephone number entry. The Model 1108 will respond:“Enter number.”

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

4. Enter the complete telephone number using the numberkeys.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

Page 38: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

26

5. Press ENTER. The unit will respond with “Enter.”

ENTERTONE

PM

6. Repeat above procedure to program up to eight separatetelephone numbers.

4.2.2 Interrogating a Dial-out Telephone Number

To interrogate dial-out telephone numbers:

1. Press WHAT IS.

WHAT IS*

2. Press PHONE NUMBER.

PHONE NUMBER

3. Press a number key (from 1 to 8).

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

Model 1108 will recite the corresponding telephonenumber. If there is no number programmed for aparticular key, the unit will respond: “No number.”

4.2.3 Erasing a Telephone Number

To erase a telephone number:

1. Press SET.

SET#

2. Press PHONE NUMBER.

PHONE NUMBER

Page 39: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

27

3. Press the number key (from 1 to 8) representing thetelephone number you want to erase.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

4. Press ENTER. The Model 1108 will say, “Enter.”

ENTERTONE

PM

4.3 Tone or Pulse Dialing

The Model 1108 can dial out in pulse or Touch-Tone™. Selectthe type of dialing, in either pulse or tone, depending upon thetype of service provided by your telephone company. Thedefault is tone.

To program for either pulse or tone:

1. Press the SENSOR ON/OFF key.

SENSORON/OFF

2. Press TONE.

ENTERTONE

PM

The Model 1108 will respond: “Off” to indicate that tonedialing is off and pulse is enabled, or “On” to indicatethat tone dialing is on and pulse is disabled.

3. Repeat key sequence to switch between settings.

4.4 Special Dialing

The Model 1108 has provisions for special dialing sequences.Special dialing sequences allow:

• Dialing that requires an access number to connect withan outside line.

Page 40: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

28

• Dialing that requires the pound (#) or asterisk (*).

• Dialing to a beeper or pager.

4.4.1 Special Dialing Keys

The following designated keys represent special functionswhen used with PHONE NUMBER entries:

1. Pause

RING/TADPAUSE

AM

PAUSE represents a four second pause in dialing. It canbe used when an access number is required before dialingto an outside line. (For example, in some cases a “9” orother number, must be dialed first, in order to get a dialtone for an outside line.) When interrogating telephonenumbers, PAUSE is audibly represented by a “beep.”

2. Pound (#)

SET#

A pound may be required when calling some phone orbeeper systems. When interrogating telephone numbers,pound (#) is audibly represented by the word “twelve.”

3. Asterisk (*)

WHAT IS*

An asterisk may be required when calling some phone orbeeper systems. When interrogating telephone numbers,asterisk (*) is audibly represented by the word “eleven.”

4. Code

CODEMUTE

CODE instructs the Model 1108 to wait until the call isanswered before continuing. When interrogatingtelephone numbers, CODE is audibly represented by theword “fourteen.”

Page 41: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

29

NOTE

Each time a pause, pound (#) or asterisk (*) isincorporated in a programming sequence, it iscounted as one digit toward the total of 32 digitsallowed.

4.4.2 Incorporating a Pause

Incorporate PAUSE to access an outside telephone line:

1. Press SET.

SET#

2. Press PHONE NUMBER.

PHONE NUMBER

3. Press any unassigned number key (from 1 to 8) torepresent the new telephone number entry. Model 1108will respond: “Enter number.”

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

4. From the number keys, enter the access digit (i.e., 9).The Model 1108 will recite the digit.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press PAUSE. The Model 1108 will beep.

RING/TADPAUSE

AM

Page 42: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

30

6. Enter the complete telephone number (1 + area code)using the number keys. The Model 1108 will recite thedigits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

7. Press ENTER. The Model 1108 will respond: “Enter.”

ENTERTONE

PM

4.4.3 Incorporating a Pound (#) or Asterisk (*)

Incorporate a pound or asterisk if it is normally included intelephone number:

1. Press SET.

SET#

2. Press PHONE NUMBER.

PHONE NUMBER

3. Press any unassigned number key (from 1 to 8) torepresent the new telephone number entry. Model 1108will respond: “Enter number.”

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

Page 43: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

31

4. Enter the telephone number using the number keys. TheModel 1108 will recite the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Position the pound (#) or asterisk (*) within the telephonenumber where required by pressing SET (where thepound is located) or WHAT IS (where the asterisk islocated). The Model 1108 will beep each time pound orasterisk is pressed.

SET# –OR–

WHAT IS*

6. Enter any remaining digits of the telephone number.

7. Press ENTER. The Model 1108 will say “Enter.”

ENTERTONE

PM

4.4.4 Special Dialing to a Beeper or Pager

The following example demonstrates just one solution toprogramming the Model 1108 for dialing to a beeper or pager.Many other key sequences will also work. Start with steps 1–3below; next, enter special dialing keys where required for yourbeeper or pager service.

To incorporate a pound or asterisk:

1. Press SET.

SET#

2. Press PHONE NUMBER.

PHONE NUMBER

Page 44: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

32

3. Press any unassigned number key (from 1 to 8) torepresent the new telephone number entry.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

4. Enter the complete telephone number using the numberkeys. The Model 1108 will recite the digits as they arepressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press CODE. This instructs the Model 1108 to wait forthe telephone call to be answered by the beeper or pagerservice. (A voice message will not occur—only digitaltones are used.) Note that CODE may not work withbeepers where there is no ring before the beeper connects.If that proves to be the case for your particular beeper,skip the CODE step and proceed from Step 4 to Step 6.

CODEMUTE

6. Now press PAUSE once to activate a four second delay.This assumes the call is answered by a beeper/pagerservice that immediately delivers a prerecorded voicemessage. PAUSE may be pressed more than once toprogram more time for the beeper/pager service to finishits message. Each press of PAUSE allocates four addi-tional seconds. The Model 1108 will beep with eachpress.

RING/TADPAUSE

AM

Page 45: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

33

7. Enter a telephone number or custom code number thatwill identify the Model 1108 as the caller to your beeperor pager. A code may consist of any number(s) youdesignate. Many users find it convenient to use thetelephone number to which the Model 1108 is connected.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

8. A pound or asterisk may be required in some dialingsituations. If required, position the pound (#) or asterisk(*) within the telephone number where required bypressing SET (where the pound is located) or WHAT IS(where the asterisk is located). The Model 1108 will beepeach time pound or asterisk is pressed. Enter any remain-ing digits of the telephone number.

SET# –OR–

WHAT IS*

9. Press ENTER. The Model 1108 will say “Enter.”

ENTERTONE

PM

4.5 Rings Until Answer

Rings Until Answer is the programmed number of times thetelephone rings before the Model 1108 will answer an incom-ing call. This can be set from 1 to 15 rings. The default value is4.

4.5.1 Programming Rings Until Answer

To program Rings Until Answer:

1. Press SET.

Page 46: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

34

SET#

2. Press RING/TAD. The Model 1108 will respond: “Enternumber.”

RING/TADPAUSE

AM

3. Using the number keys, enter a value.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

4. Press ENTER. The Model 1108 will respond: “Enter.”

ENTERTONE

PM

4.5.2 Interrogating Rings Until Answer

To interrogate Rings Until Answer:

1. Press WHAT IS.

WHAT IS*

2. Press RING/TAD.

RING/TADPAUSE

AM

4.6 TAD (Telephone Answering Device)

The TAD feature is especially useful because it integrates theoperation of the Model 1108 with your telephone answeringdevice in a way that retains the full flexibility of each system.This allows you to have on-demand telephone access to theModel 1108, for obtaining a Status Report, or for issuing call-in

Page 47: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

35

commands, while your telephone answering device is set toreceive outside calls. Programming for use with a telephoneanswering device (TAD) is always used in conjunction withRings Until Answer, detailed in section 4.5.

NOTE

The TAD feature only applies to answeringdevices connected to the same telephone line asthe Model 1108.

4.6.1 TAD Enable/Disable

To enable/disable the TAD feature:

1. Press SENSOR ON/OFF.

SENSORON/OFF

2. Press RING/TAD.

RING/TADPAUSE

AM

The Model 1108 will respond: “On.” (If the Model 1108says “Off,” repeat steps 1 and 2 to reactivate TAD.)

4.6.2 Using the TAD Feature

1. Make sure the TAD feature is enabled on the Model 1108.(The default setting is disabled, so you must enable itfirst.)

2. Determine the number of rings your telephone answeringdevice uses to answer the telephone. (Most answeringdevices require 4 rings; others are selectable.)

3. On the Model 1108, program Rings Until Answer to agreater number than the number of rings set on youranswering machine.

Example:

Telephone answering device, rings = 4

Model 1108, Rings Until Answer = 6

Page 48: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

36

Using the procedure just outlined, all incoming calls will beanswered by the telephone answering device, allowing it tooperate normally. With the programming just accomplished, theModel 1108 can be accessed remotely, by telephone, to obtainthe Status Report.

1. Dial the telephone number of the Model 1108.

2. Let the telephone ring once and then hang up.

3. Wait approximately ten seconds

4. Call the Model 1108 back.It will answer the telephone on the first ring.

Explanation: The pattern of one ring, followed by a second call(within 30 seconds), signals the Model 1108 to answer yourincoming call, excluding the telephone answering device.

NOTE

Special Case: If the Model 1108 shares the sameline with a telephone answering device, andduring certain time periods, frequent, incomingcalls are expected on that line, then you maywant to temporarily disable the TAD feature. Ifyou leave the TAD enabled, it will not adverselyaffect normal operation, but if two outsidetelephone calls are received within the same30-second time window, the Model 1108 willinterpret this pattern as a signal to answer thetelephone. If this occurs, press any key on theModel 1108 to hang up.

4.6.3 No TAD In Use

If a telephone answering device is not used on the sametelephone line as the Model 1108, make sure that theTAD feature is disabled, or turned off. Only Rings UntilAnswer programming will determine how incoming callsare answered. For example, if you program Rings UntilAnswer to 3, incoming calls will be answered in 3 rings.

Page 49: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

37

4.7 Listen-in Time

The Listen-in Time is the amount of time you can listen tosounds from the Model 1108’s built-in microphone at itsinstallation site. When you call in for a Status Report, theModel 1108 announces Listen-in Time at the end of its firstround of status readings, saying, “Listen to the sound level for(programmed time entered).” The programmable range is from0 to 255 seconds (or up to 4.17 minutes). The default value is15 seconds.

NOTE

The microphone is also used to monitor highsound level. See Chapter 5, Section 5.10 throughSection 5.11.1.

4.7.1 Programming the Listen-in Time

To program the Listen-in Time:

1. Press SET.

SET#

2. Press LISTEN TIME. The Model 1108 will respond:“Enter seconds.”

9

LISTEN TIME SOUND

3. Using the number keys, enter the seconds. The Model1108 will recite the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

4. Press ENTER. The Model 1108 will respond: “Enter.”

ENTERTONE

PM

Page 50: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

38

4.7.2 Interrogating the Listen-in Time

To interrogate the Listen-in Time:

1. Press WHAT IS.

WHAT IS*

2. Press LISTEN TIME. The Model 1108 will recite thelisten time in seconds programmed.

9LISTEN TIME

SOUND

4.8 Call Delay

Call Delay is the programmed length of time the Model 1108waits, following detection of an alarm, before it begins the dial-out sequence. This applies only to the first call. (Delay timebetween calls is also programmable: refer to Intercall Time,Section 4-11.)

The purpose for Call Delay is to allow time for personnel at theModel 1108’s installation site to respond to and cancel an alarmbefore dial-out begins. During this time, the Model 1108 willaudibly repeat its “alert condition” message (unless the LocalVoice Mute feature has been activated—refer to Section 4.9).The default for Call Delay is 30 seconds. Call Delay can beprogrammed from 0 seconds to 60 minutes (1 hour).

4.8.1 Programming the Call Delay

To program the Call Delay:

1. Press SET.

SET#

2. Press CALL DELAY.

1CALL

DELAY

The Model 1108 will respond: “Enter minutes.”

Page 51: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

39

3. Using the number keys, enter the minutes.The Model 1108 recites the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

4. Press ENTER. The Model 1108 responds: “Enterseconds.”

ENTERTONE

PM

5. Using the number keys, enter the seconds.The Model 1108 recites the digits as you press them.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

6. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

4.8.2 Interrogating Call Delay

To interrogate Call Delay:

1. Press WHAT IS.

WHAT IS*

2. Press CALL DELAY.

1CALL

DELAY

The Model 1108 will recite the programmed Call Delay.

Page 52: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

40

4.9 Local Voice Mute

When the Model 1108 dials out to report an alarm, it alsoaudibly recites the alarm message at its installation site. TheLocal Voice Mute command allows you to turn off the voice atthe Model 1108’s site during alarm dialouts and status call-ins.This feature is used to prevent intruders or unauthorizedpersons from hearing the alarm dial-out message or fromhearing the Status Report during an off-site call.

4.9.1 Enable/Disable Local Voice Mute

To enable/disable Local Voice Mute:

1. Press SENSOR ON/OFF.

SENSORON/OFF

2. Press MUTE.

CODEMUTE

The Model 1108 will say “On” to indicate that LocalVoice Mute is enabled, or“Off” to indicate that it isdisabled.

3. Repeat key sequence to switch between enabled ordisabled Local Voice Mute.

4.10 Voice Repetitions

The Voice Repetitions feature allows programming of thenumber of times the alarm message is delivered per phone callduring alarm dial-out.

The maximum repetitions may be set to 10; the default is3 repetitions.

Page 53: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

41

4.10.1 Programming Voice Repetitions

To program Voice Repetitions:

1. Press SET.

SET#

2. Press VOICE REPS.

VOICEREPS

2

The Model 1108 will respond:“Enter number.”

3. Using the number keys, enter a value from 0 to 10.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

4. Press ENTER. The Model 1108 will respond:“Enter.”

ENTERTONE

PM

4.10.2 Interrogating Voice Repetitions

To interrogate Voice Repetitions:

1. Press WHAT IS.

WHAT IS*

2. Press VOICE REPS.

VOICEREPS

2

The Model 1108 will recite the number programmed.

Page 54: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

42

4.11 Intercall Time

The Intercall Time is the programmable period of time theModel 1108 waits in calling subsequent telephone numbers.Intercall Time is activated only after alarm dial-out to the firsttelephone number fails to be acknowledged. This period canbe programmed from 10 seconds to 60 minutes. The defaultintercall time is 1 minute.

If an incoming telephone call is made to the Model 1108 duringIntercall Time (in between its dialing of subsequent telephonenumbers to report an alarm), it will answer the incoming calland immediately report any existing alarms. The manner inwhich the incoming call is answered depends upon whether ornot TAD is enabled or disabled:

• If TAD (Telephone Answering Device) is enabled,Rings Until Answer will be 1.

• If TAD is disabled, Rings Until Answer will be 10.

Refer to Section 4.5, Rings Until Answer, and Section 4.6,TAD (Telephone Answering Device).

4.11.1 Programming Intercall Time

To program Intercall Time:

1. Press SET.

SET#

2. Press INTERCALL TIME.

INTERCALLTIME

3

The Model 1108 will respond: “Enter minutes.”

3. Using the number keys, enter the minutes.The Model 1108 recites the digits as you press them.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

Page 55: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

43

4. Press ENTER. The Model 1108 will respond: “Enterseconds.”

ENTERTONE

PM

6. Using the number keys, enter the seconds. TheModel 1108 recites the digits as you press them.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

7. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

4.11.2 Interrogating Intercall Time

To interrogate Intercall Time:

1. Press WHAT IS.

WHAT IS*

2. Press INTERCALL TIME.

INTERCALLTIME

3

The Model 1108 will recite the programmedIntercall Time.

4.12 Maximum Number of Calls (Max Calls)

The Max Calls feature controls the total number of repeatedcalling attempts by the Model 1108 in the event of an alarm.When an alarm occurs, the dial-out process begins, andcontinues to cycle through your programmed telephone

Page 56: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

44

numbers until a maximum number of calls is reached. The MaxCalls setting regulates the number of calls that will be made asa result of any alarms; if more than one alarm is detected atonce, or if a second alarm occurs during dial-out on the firstalarm, the Max Calls setting will start the calling process fromzero, until the programmed number of calling attempts arecompleted.

The default setting for Max Calls is 100, but it may be pro-grammed from 0 to 255 calls. Max Calls is cancelled when analarm is acknowledged. If the maximum number of calls iscompleted and no alarm acknowledgement has occurred, theModel 1108 will automatically acknowledge any alarm andstop the dial-out.

NOTE

If only one telephone number is programmed,the Model 1108 will dial out a maximum of 15times to report an alarm.

4.12.1 Programming Max Calls

To program Max Calls:

1. Press SET.

SET#

2. Press MAX CALLS.

4MAX CALLS

The Model 1108 will respond:“Enter number.”

3. Using the number keys, enter a value. The Model 1108will recite the digits as you press them.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

Page 57: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

45

5. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

4.12.2 Interrogating Max Calls

To interrogate Max Calls programmed:

1. Press WHAT IS.

WHAT IS*

2. Press MAX CALLS.

4MAX CALLS

The Model 1108 will recite the value set for Max Calls.

4.13 The Clock

The Model 1108 has a built-in clock. The power-up time is 12AM. The clock will keep time from 12 AM until you programthe current time. It will then keep time from your programmedtime. If the AC power fails, the clock will continue to keep timeuntil the battery back-up fails. It will then reset to 12 AM whenpower is restored. An incorrect time is a good indication thatthe power has failed and the batteries have been expended.

4.13.1 Setting the Clock

To set the clock:

1. Press SET.

SET#

2. Press CLOCK.

8CLOCK

Page 58: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

46

3. Using the number keys, enter the correct time. TheModel 1108 will recite the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

4. If the time is AM, press the AM key. The Model 1108 willbeep. (If the time is PM , there is no key to press—theclock will be automatically set to PM if AM is not set.)

RING/TADPAUSE

AM

5. Press ENTER. The Model 1108 will respond: “Enter.”

ENTERTONE

PM

Example: You want to set the clock to 12:45 AM. Press thefollowing keys in the order shown:

SET…CLOCK…1…2…4…5…AM…ENTER.

4.13.2 Interrogating for the Current Time

To interrogate the Model 1108 for the current time:

1. Press WHAT IS.

WHAT IS*

2. Press CLOCK. The Model 1108 will recite theprogrammed time.

8CLOCK

Page 59: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 4: Communications Programming

47

4.14 The Security Code

The Security Code is the last step after setting all otherprogramming parameters for the Model 1108. The codeconsists of a 4-digit number you select and will effectivelyprevent unauthorized changes to the Model 1108’s program-ming. When the Security Code is activated, all keyboardprogramming is inaccessible. The Model 1108 may be interro-gated using the WHAT IS key, but the keyboard must beunlocked, via the Security Code, before any additional pro-gramming is possible.

4.14.1 Locking the Keypad

To program the Security Code:

1. Press SET.

SET#

2. Press CODE.

CODEMUTE

The Model 1108 will respond: “Enter security code.”

3. Using the number keys, enter 4 digits. The Model 1108says “OK.” The keyboard is now locked.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

If unauthorized persons attempt to set a parameter, anerror message, “Error 2,” is returned. Whenever anyoperation except WHAT IS takes place without enteringthe security code first, this error message occurs.

Page 60: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

48

4.14.2 Unlocking the Keypad

To unlock the keyboard:

1. Press WHAT IS.

WHAT IS*

2. Press CODE.

CODEMUTE

The Model 1108 will respond: “Enter Security Code.”

3. Using the number keys, enter the digits for the code.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

.

If the correct code is entered, the Model 1108 will say“OK.” If the wrong code is entered, the Model 1108 willsay “Error 2.”

Page 61: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

49

Chapter 5: Alarm Programming

This chapter explains the alarm programming and monitoringcapabilities of the Model 1108, with specific instructions forthe following features:

• Configure inputs as dry contact or temperature

• Enable/disable inputs

• Program alarm Recognition Time for each input

• Program high and low temperature limits

• Disable alarm response to high or low temperature

• Program temperature in Fahrenheit or Celsius scale

• Calibrate temperature

• Obtain current temperature

• Program AC power-failure Recognition Time

• Enable/disable AC power monitoring

• Program sound level sensitivity

• Program high sound Recognition Time

• Disable alarm response to high sound

• Use Exit Delay via Status Report

5.1 Input Configuration

In preparing the Model 1108 to sense an alert condition, theinputs must be configured as dry contact (either open or closed)or as temperature inputs. The default setting for input 1 istemperature; for inputs 2-8, the default is dry contact and open.To configure input normality, sensors are first wired to theterminal strip at the back of the unit. (Refer to Chapter 2,Section 2.9–2.12, for an explanation on wiring inputs.)

The configuration process directs the Model 1108 to initializethe 8 inputs and establish normal settings. Any change in thestatus of an input (for example, from a normally open contactto a suddenly closed contact) is recognized as an alert condi-tion. In the case of a temperature input, an alert condition isrecognized when established temperature limits are exceeded.

Page 62: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

50

NOTE

Before starting keyboard commands to configureinput normality on the Model 1108, it is veryimportant to check that the sensors you havewired to the unit are set in their normal, non-alarm positions. For example, if a magnetic reedswitch (a normally-closed sensor used to detectunauthorized entry) has been wired to theModel 1108, make sure that the door or windowto be monitored is shut before configuring theinput. If a motion-detector is wired to the unit, itis advisable to block all sources of motion fromthe sensor before and during configuration.

5.1.1 Programming Input Configuration

1. Press STANDBY to place the Model 1108 inStandby mode.

RUNSTANDBY

2. Wire sensors to the inputs to the back of the Model 1108(see Chapter 2, Section 2.10).

3. Press RUN. The red light glows when the Model 1108returns to Run mode.

RUNSTANDBY

4. Press SET.

SET#

5. Press CONFIGURE.

STATUSCONFIGURE

Page 63: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

51

6. The Model 1108 audibly recites the configuration for eachof the eight inputs:

• If the input is normally open, the Model 1108 recites thenumber of the input and says“OK.”

• If the input is normally closed, the Model 1108 recitesthe number of the input, followed by a beep and“OK.”

• If the input is configured as temperature, theModel 1108 recites the number of the input, followed by“Temperature.”

5.1.2 Verifying Input Configuration

Input configuration can be verified when interrogating theModel 1108 for a complete Status Report. Refer to Chapter 6for a more detailed description of the Status Report.

5.2 Enable/Disable Inputs

This function allows you to enable or disable an input’sresponse to an alert condition. An enabled input will respond toan alert condition and allow dial-out. A disabled input willcause dial-out to be suppressed, but any existing alert condi-tions will be revealed during the Status Report. Enable/disableprogramming is useful during wiring of inputs (see Chapter 2)or when a condition needs to be monitored, but is not criticalenough to be programmed for dial-out reporting. It is importantto verify input status after performing any task that requiresdisabling. The default setting for all inputs is enabled (ON).If an alert condition exists when inputs are re-enabled,Recognition Time will restart—refer to Section 5.3.

Page 64: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

52

5.2.1 Changing Enabled/Disabled Input Status

1. Press SENSOR ON/OFF.

SENSORON/OFF

2. Press the number (1 to 8) of the selected input to enable/disable. The Model 1108 says “Off” to indicate disabledor “On” to indicate enabled.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

5.2.2 Verifying Enabled/Disabled Input Status

1. Press WHAT IS.

WHAT IS*

2. Press STATUS.

STATUSCONFIGURE

The Model 1108 audibly recites the current status of everyinput. In a Status Report, each input is first identified by itsinput number, followed by a report that specifies parameterscurrently affecting that input. If an input is disabled, the word“Off” immediately follows the number recited for that input.

For example, input 3 is configured as a normally open, drycontact input. During the Status Report:

• If disabled, the Model 1108 recites:“Number 3—Off—OK,” for input 3.

• If enabled, the Model 1108 recites:“Number 3—OK,” for input 3.

Page 65: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

53

In another example, input 5 is configured as a temperatureinput. The current temperature is 76 degrees. During a StatusReport:

• If disabled, the Model 1108 recites “Number 5—Off—76 degrees—OK.”

• If enabled, the Model 1108 recites “Number 5—76 degrees—OK.”

5.3 Input Recognition Time

The Input Recognition Time is the length of time an alertcondition must be present before a valid alarm exists and dial-out is activated. This time period is programmable, from 0minutes, 0 seconds (for immediate response) up to a period of272 minutes, 0 seconds. If an alert condition begins and thenclears within the established Recognition Time, no dial-out willoccur. When an alert condition continues beyond the pro-grammed Recognition Time, the Model 1108 initiates dial-out.The default setting for Input Recognition Time is 0 minutes,3 seconds.

5.3.1 Programming Input Recognition Time

1. Press SET.

SET#

2. Press RECOGNITION TIME.

RECOGNITION TIME

7

3. Press the number (1 to 8) of the selected input to beprogrammed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

The Model 1108 responds: “Enter minutes.”

Page 66: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

54

4. Using the number keys, enter the minutes. For example, toset a Recognition Time of five minutes, simply press “5”on the keypad. The Model 1108 recites the digits as theyare pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press ENTER. The Model 1108 responds: “Enterseconds.”

ENTERTONE

PM

6. Using the number keys, enter the seconds. TheModel 1108 recites the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

7. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

5.3.2 Interrogating Input Recognition Time

1. Press WHAT IS.

WHAT IS*

2. Press RECOGNITION TIME.

RECOGNITION TIME

7

Page 67: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

55

3. Press the corresponding input key (1 to 8).

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

The Model 1108 recites the programmed RecognitionTime for that input.

5.4 Establishing High and Low Temperature Limits

High and low temperature limits can be separately programmedfor each input configured as temperature. Limits can rangefrom–20° to +150° Fahrenheit, or from –30° to 65° Celsius.

When temperature limits exceed high or low settings, theModel 1108 will dial out with an alarm message. Defaultsettings are: 10° F for low temperature and 100° F for hightemperature.

5.4.1 Programming Temperature Limitsfor a Selected Input

1. Press SET.

SET#

2. Press TEMP LIMITS.

TEMP LIMITS

5

3. From the number keys, press a number (from 1 to 8) thatcorresponds to the temperature input being programmed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

The Model 1108 responds: “Enter low temperaturelimit.”

Page 68: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

56

4. Using the number keys, enter a value for low temperaturelimit. The Model 1108 will recite the digits as they arepressed. If a negative number is required, first pressPAUSE, then enter the number.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press ENTER.

ENTERTONE

PM

The Model 1108 responds: “Enter high temperaturelimit.”

6. Using the number keys, enter the value for high tempera-ture limit. The Model 1108 recites the digits as they arepressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

7. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

NOTE

Do not set temperature limits too close to normalroom temperature. Minor temperature fluctua-tions could result in frequent and unnecessaryalarm dialouts.

5.4.2 Disabling Alarm Response to High orLow Temperature

To disable alarm response to either high or low temperaturesettings exclusively, enter the maximum temperature limitwhen programming the selected input. (The Model 1108 will

Page 69: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

57

not respond to temperatures encountered at maximum settingsor beyond.) Begin by following the key sequence shown inSection 5.4.1, and when prompted to enter the high or lowtemperature value:

• Set high temperature to either +150o F or +65o C (hightemperature limit) to prevent the Model 1108 fromresponding to a high temperature alarm.

• Set low temperature to either -20o F or -30o C to preventthe Model 1108 from responding to a low temperaturealarm.

5.4.3 Interrogating High and Low Temperature Limits

1. Press WHAT IS.

WHAT IS*

2. Press TEMP LIMITS.

TEMP LIMITS

5

3. Press the number key corresponding to the selectedtemperature input.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

5.5 Temperature Scale

Temperature inputs may be set in either Fahrenheit or Celsiusdegrees. The default temperature scale is Fahrenheit. To changeto Celsius:

1. Press SENSOR ON/OFF.

SENSORON/OFF

Page 70: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

58

2. Press TEMP. The Model 1108 responds: “Off,” indicatingCelsius scale has replaced Fahrenheit scale.

TEMPF / C

3. To return to Fahrenheit scale, repeat the key sequence.The Model 1108 responds: “On,” indicating Fahrenheitscale is in effect.

NOTE

When switching from Fahrenheit to Celsius, orvice versa, the change applies to all inputsconfigured to read temperature. When switchingtemperature scales it is important to reset highand low temperature limits on all temperatureinputs. Refer to Section 5.4.1 to resettemperature limits.

5.6 Temperature Calibration

To compensate for minor variances in sensor accuracy, an offsetmay be programmed for each temperature input. The amount ofoffset is measured in degrees Fahrenheit or degrees Celsius.Adjustments are possible within a range from -10 degrees to+10 degrees. For example, if input 3 is sensing temperature andis reading 1 degree too high, then the calibration for input 3 isset at -1 to obtain an accurate reading.

5.6.1 Programming Temperature Calibration

1. Press SET.

SET#

2. Press CALIBRATE.

CALIBRATE

6

Page 71: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

59

3. Press the number (1 to 8) of the selected temperatureinput to be calibrated.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

4. Enter the number required to offset the current tempera-ture reading so a correct reading is obtained.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

• To program a positive offset number (up to +10degrees), enter the number on the keypad. The Model1108 recites the digits as they are pressed.

• To program a negative offset number (up to –10degrees), first press PAUSE. The unit responds with a“beep.” Next, enter the number on the keypad. The unitrecites the digits as they are pressed.

5. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

NOTE

If you find that your calibration offset exceedsmore than + 5 or – 5 degrees, other complicatingfactors could be affecting normal operation ofthe Model 1108. Call Phonetics for technicalassistance.

Page 72: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

60

5.6.2 Interrogating Temperature Calibration

1. Press WHAT IS.

WHAT IS*

2. Press CALIBRATE.

CALIBRATE

6

3. Press the number key corresponding to the selectedtemperature input.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK

TEMP LIMITS

5CALIBRATE

6

If a “beep” precedes the number as it is recited, then anegative offset is indicated.

5.7 Obtaining Current Temperature

Current temperature readings for each temperature input maybe accessed at any time. The Model 1108 recites the inputnumber, and the actual temperature detected by the attachedsensor, for all inputs configured as temperature. To obtaincurrent temperature:

1. Press WHAT IS.

WHAT IS*

2. Press TEMP.

TEMPF / C

Page 73: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

61

5.8 AC Power Monitoring Enable/Disable

The Model 1108 monitors AC power failure. This commandenables or disables the power failure detection feature. Whenenabled, the Model 1108 will monitor power and dial out whenAC power failure exceeds a programmable span of time (referto AC Power Failure Recognition Time, Section 5.9).The default setting for AC power monitoring is enabled (on).When disabled, the Model 1108 will not dial-out to reportpower failure.

5.8.1 Enabling/Disabling the AC Power Alarm

1. Press SENSOR ON/OFF.

SENSORON/OFF

2. Press POWER.

0ID NUMBER

POWER

• The Model 1108 will say “Off” to indicate that thepower alarm is disabled, or

• The Model 1108 will say “On” to indicate that thepower alarm is enabled.

3. Repeat key sequence to change settings.

5.9 AC Power Failure Recognition Time

The AC Power Failure Recognition Time is the length of timethat AC electric power is off before a valid alarm is recognizedand dial-out begins. The default setting is 5 minutes, 0 seconds,but is programmable from 0 seconds to a maximum of272 minutes.

When AC power failure occurs, and throughout the pro-grammed Recognition Time, the Model 1108 steadily repeatsthe message “the electricity is off” at the unit’s installation site.There is no Call Delay programming available for AC powerfailure. Immediately following Recognition Time, the Model1108 begins the dial-out process to report power failure.

Page 74: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

62

To cancel the power-failure message locally at the keypad(during or after Recognition Time) press any key on theModel 1108 keypad. This action also cancels the dial-outprocess. The AC power failure alarm may also be cancelledremotely, by telephone acknowledgment (see Chapter 6,Section 6.1).

5.9.1 Programming Power Failure Recognition Time

1. Press SET.

SET#

2. Press RECOGNITION TIME.

RECOGNITION TIME

7

3. Press POWER. The Model 1108 responds: “Enterminutes.”

0ID NUMBER

POWER

4. Using the number keys, enter the number of minutes. TheModel 1108 will recite the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press ENTER. The Model 1108 responds: “Enterseconds.”

ENTERTONE

PM

Page 75: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

63

6. Using the number keys, enter the number of seconds. TheModel 1108 will recite the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

7. Press ENTER. The Model 1108 responds:“OK.”

ENTERTONE

PM

5.9.2 Interrogating Power Failure Recognition Time

1. Press WHAT IS.

WHAT IS*

2. Press RECOGNITION TIME.

RECOGNITION TIME

7

3. Press POWER.The Model 1108 will recite the power Recognition Time.

0ID NUMBER

POWER

5.10 Sound Alarm Monitoring

This feature allows you to program the level and duration ofsound that will cause the Model 1108 to respond to an alarmand dial-out. It may be useful to desensitize the Model 1108 tosound if it is installed in an area with a relatively high noiselevel, or where a loud noise occurs frequently but is notassociated with an alarm. In some applications, it may bedesirable to increase sound sensitivity to low sound levels.

Page 76: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

64

5.10.1 Programming Sound Alarm Sensitivity

The sensitivity setting for sound alarm monitoring ranges from1 to 255. A value of 1 makes the microphone the MOSTsensitive to changes in sound. The value 255 makes themicrophone the LEAST sensitive to sound. The default valueis 32.

1. Press SET.

SET#

2. Press CALIBRATE.

CALIBRATE

6

3. Press SOUND. The Model 1108 responds: “Enternumber.”

9LISTEN TIME

SOUND

4. Using the number keys, enter a value for sound sensitivity.The Model 1108 recites the digits as you press them.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

5. Press ENTER. The Model 1108 responds: “Enter.”

ENTERTONE

PM

5.10.2 Interrogating Sound Sensitivity

1. Press WHAT IS.

WHAT IS*

Page 77: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

65

2. Press CALIBRATE.

CALIBRATE

6

3. Press SOUND. The Model 1108 recites the programmedsound sensitivity level.

9LISTEN TIME

SOUND

5.10.3 Programming High Sound AlarmRecognition Time

The Recognition Time for sound alarm monitoring ranges from2 seconds to 59 seconds. The default value is 8 seconds.

1. Press SET.

SET#

2. Press RECOGNITION TIME.

RECOGNITION TIME

7

3. Press SOUND. The Model 1108 responds: “Enterseconds.”

9LISTEN TIME

SOUND

4. Using the number keys, enter the number of seconds. TheModel 1108 will recite the digits as they are pressed.

RECOGNITION TIME

7

4

1VOICEREPS

2

8

0ID NUMBER

POWER

9

INTERCALLTIME

3

MAX CALLS

CALLDELAY

CLOCK LISTEN TIME SOUND

TEMP LIMITS

5CALIBRATE

6

Page 78: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

66

5. Press ENTER.

ENTERTONE

PM

5.11 High Sound Alarm Enable/Disable

The Model 1108 monitors sound through the built-inmicrophone. When the sound level suddenly exceeds theprogrammed high sound limit, the Model 1108 will respond toan alert condition. The increased sound level must continuethroughout the programmed recognition time. The default forhigh sound alarm is enabled (on).

NOTE

The microphone is also used for listening toon-site sounds. Refer to Chapter 4, Section 4.7.Disabling the sound alarm does not affectlisten-in capability.

5.11.1 Changing Enabled/Disabled High Sound Alarm

1. Press SENSOR ON/OFF.

SENSORON/OFF

2. Press SOUND. The Model 1108 will say “Off” toindicate disabled or “On” to indicate enabled.

9LISTEN TIME

SOUND

3. Repeat key sequence to change settings.

5.12 Exit Delay

When tripping an alarm is unavoidable, yet a true alertcondition has not actually occurred, the alarm response,including dial-out, can be temporarily suppressed.

Page 79: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 5: Alarm Programming

67

The Model 1108 is able to suppress and then reset its dial-outfunction automatically through use of the Status Report. This isespecially convenient when an alert condition is created uponexiting a monitored door and there is no way to cancel from thelocal keypad.

Example: You are planning to exit through a monitored door.Prior to exiting, you initiate a Status Report recitation at theModel 1108 keypad by pressing WHAT IS, followed bySTATUS, (key sequence shown below). You have approxi-mately 30 seconds to exit without activating the Model 1108’sprogrammed alarm response. At the conclusion of the StatusReport, normal alarm response is reactivated.

To use exit delay, initiate the Status Report.

1. Press WHAT IS.

WHAT IS*

2. Press STATUS. The Model 1108 recites the full StatusReport; during this time, you are able to exit themonitored area without tripping an alarm.

STATUSCONFIGURE

Page 80: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

68

NOTES

Page 81: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

69

Chapter 6: Acknowledgment, Status Report, and Remote Access

Chapter 6: Acknowledgment,Status Report, andRemote Access

In addition to communication and alarm monitoringcapabilities, the Model 1108 will also respond to yourinstructions and provide you with access to information onmonitored conditions at all times.

By issuing commands to the unit, either at the installation siteor over standard telephone lines, the following features may beactivated:

• Acknowledgment of existing alarms

• The Status Report on all monitored conditions.

6.1 Alarm Acknowledgment

When the Model 1108 dials out with an alarm message, it willrequest acknowledgment before hanging up. Acknowledgmentindicates to the unit that the alarm message has been received.Upon acknowledgment, the Model 1108 will cancel the dial-outsequence.

There are three ways* that an alarm is acknowledged directly:

• Local Acknowledgment

• Touch-ToneTM Acknowledgment

• Callback Acknowledgment

* A fourth method of alarm acknowledgment is indirect. Referto Max Calls, Chapter 4, Section 4.12 for an example ofautomatic alarm acknowledgment.

6.1.1 Local AcknowledgmentTo acknowledge an alarm locally (directly at the installationsite of the Model 1108), press any key.

6.1.2 Touch-ToneTM AcknowledgmentThis method of remote alarm acknowledgment works with aTouch-ToneTM telephone.

Page 82: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

70

Example: You receive a call from the Model 1108, reportingthat an alarm exists. The message concludes: “Indicate youhave received warning message.” Now, or at any time duringthis call, you may acknowledge the alarm with the code “555”if you are using a Touch-ToneTM telephone.

• To enter “555,” press the number (5) key on the Touch-ToneTM phone keypad three times. The Model 1108 willrespond: * “Warning message received by telephonenumber (last number dialed).” The Model 1108 willhang up and the dial-out sequence, including any furtherresponse to the alarm, will be cancelled.

• If you enter the wrong code or do not enter it within10 seconds following the conclusion of the message, theModel 1108 will respond: “Dial telephone number (theprogrammed unit phone number) within (IntercallTime).” Then, the Model 1108 will hang up. The alarmis still not acknowledged until you call back. You have aperiod equal to the programmed Intercall Time to callthe unit back in order to acknowledge the alarm. Referto Callback Acknowledgment, Section 6.1.3, below.

6.1.3 Callback Acknowledgment

This method of remote alarm acknowledgment works with anytelephone: pulse, rotary, or Touch-ToneTM.

Example: The Model 1108 calls you with an alarm message.You answer the call with a rotary or pulse telephone, and do thefollowing:

• You listen to the message and hang up.

• Then you call the Model 1108 back on any telephone.You must wait for 10 rings—this signals the Model1108 to answer your telephone call. (Make sure to callback within the programmed setting for IntercallTime—refer to Chapter 4, Section 4.11.)

When the Model 1108 answers your return call, it gives aStatus Report (refer to Section 6.2). Then it says:“Warningmessage received by ...” and recites the telephone number lastdialed. This indicates that the alarm has been acknowledged.

Page 83: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

71

Chapter 6: Acknowledgment, Status Report, and Remote Access

NOTE

If you have the TAD feature ( telephoneanswering device) enabled, the Model 1108 willanswer the telephone on the first ring. If it isdisabled, the telephone must be allowed to ring10 times. This serves as a precaution against arandom alarm acknowledgment. Refer toChapter 4, Section 4.6, for complete informationon using the TAD feature.

6.2 Status Report

The Status Report allows access to complete information on allmonitored conditions either locally, from the keypad, or bytelephone, from any location. The Model 1108 will answer anincoming telephone call following the programmed Rings UntilAnswer (refer to Chapter 4, Section 4.5). Included with theStatus Report are messages related to alarm conditions,AC power, battery backup and sound level. It also provides anopportunity for listening to on-site sounds (refer to Listen-inTime, Chapter 4, Section 4.7).

To initiate the Status Report:

1. Press WHAT IS.

WHAT IS*

2. Press STATUS.

STATUSCONFIGURE

Sections 6.2.1, 6.2.2, and 6.2.3 demonstrate two differentStatus Report recitations. The Status Report starts with:

“Hello. This is telephone number 555-1234 (or theprogrammed ID).”

“The time is 12:15 PM (or the current time).”

The Model 1108 proceeds with a separate report for each input.Each input identifies itself by reciting the input number.

Page 84: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

72

6.2.1 Example: Status Report, No Alarms

Inputs 2, 3, 4, and 6 are configured as dry contact and inputs 1,5, 7 and 8 are configured as temperature. No alarms exist. TheStatus Report begins by saying, “Hello, this is telephonenumber 555-1234; the time is 12:15 PM.” Following thisintroduction, the report continues:

“Number 1, 74 degrees, OK.”

“Number 2, OK.”

“Number 3, OK.”

“Number 4, OK.”

“Number 5, 76 degrees, OK.”

“Number 6, OK.”

“Number 7, 86 degrees, OK.”

“Number 8, 70 degrees, OK.”

“The electricity is ON.” This refers to AC power.

“Battery condition, OK.” Other responses: “Battery conditionlow” or “Replace batteries.” (Refer to Section 6.2.4 foradditional information regarding battery condition.)

“Sound level, OK.”

“Listen to the sound level for 10 seconds.” In this case, theprogrammed Listen-in Time is set at 10 seconds. (This featureis not available when obtaining the Status Report on-site,directly at the keypad.)

The Status Report repeats once more and the Model 1108concludes the call, saying: “Have a good day.” (The StatusReport will not repeat if obtained at the keypad; “Have a goodday,” is also not recited.)

The phrase “no number” at the end of a Status Report indicatesthat no dial-out phone numbers have been programmed.

Page 85: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

73

Chapter 6: Acknowledgment, Status Report, and Remote Access

6.2.2 Example: Status Report, Existing Alarms

Inputs 2, 3, 4, and 6 are configured as dry contact and inputs 1,5, 7 and 8 are configured as temperature. An emergencysituation is at hand: a fire in a greenhouse has tripped a smokealarm and electrical power has been disrupted. In addition tohigh sound and AC power alarms, separate alarms exist oninputs 5, 6, 7, and 8. You happen to call in for the StatusReport, which begins with, “Hello, this is telephone number555-1234; the time is 12:15 PM.” Following this introduction,the report continues:

“Number 1, 74 degrees, OK.”

“Number 2, OK.”

“Number 3, OK.”

“Number 4, OK.”

“Number 5, 105 degrees, HIGH.”

“Number 6, EXISTS.”

“Number 7, 110 degrees, HIGH.”

“Number 8, 98 degrees, HIGH.”

“The electricity is OFF.”

“Battery condition, OK.”

“Sound level, HIGH.”

“Listen to the sound level for 10 seconds.”

“Warning message received by ...(last telephone numberdialed*).”

The Status Report repeats once more and the Model 1108concludes the call, saying: “Have a good day.”

* The “last telephone number dialed” refers to any one of theprogrammed, dial-out telephone numbers through which theModel 1108 was able to receive alarm acknowledgment, priorto your call for a Status Report; this could also refer to theModel 1108’s I.D. Number, if the alarms are acknowledged atthe keypad by someone present at the site.

Page 86: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

74

6.2.3 Example: Status Report, Disabled Inputs

If an input is disabled, the dial-out feature for that input isdeactivated, but all other programmed parameters remain ineffect. In the example below, all 8 inputs are disabled, althoughinputs 5 and 6 are detecting alarms. AC power and Sound Levelare also disabled for dial-out. (Note that to indicate disabledstatus, only AC power will return two audible beeps, ratherthan the word, “OFF.”) When you call the Model 1108 for aStatus Report, you hear the following:

“Hello, this is telephone number 555-1234.

“The time is 12:15 PM.”

“Number 1, OFF, OK.”

“Number 2, OFF, 74 degrees, OK.”

“Number 3, OFF, OK.”

“Number 4, OFF, OK.”

“Number 5, OFF, 96 degrees, HIGH.”

“Number 6, OFF, EXISTS.”

“Number 7, OFF, 86 degrees, OK.”

“Number 8, OFF, 70 degrees, OK.”

“The electricity is (beep, beep), ON.” If the electricity is off,or the AC adaptor is disconnected, you will hear:“The electricity is (beep, beep), OFF.”

“Battery condition, OK.”

“Sound level, OFF, OK.” If the sound level is high you willhear: “Sound level, OFF, HIGH.”

“Listen to the sound level for 10 seconds.”

The Status Report repeats once more and the Model 1108concludes the call, saying: “Have a good day.”

Page 87: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

75

Chapter 6: Acknowledgment, Status Report, and Remote Access

6.2.4 Battery Condition

During a Status Report, you may hear one of three possiblemessages regarding battery power. The Model 1108determines the appropriate message by measuring batteryvoltage. Depending upon the remaining voltage, it mayrespond:

• “Battery Condition , OK,” if over 8.2 Volts.

• “Battery Condition , low,” if between 7.2 and 8.2 Volts.

• “Replace batteries,” if below 7.2 Volts.

6.2.5 Remote Access by Touch-Tone™ Telephone

Calling the Model 1108 for a Status Report provides theopportunity to access other functions, using Touch Tone™ push-button commands. Remote telephone commands include:

• Disabling/enabling any input.

• Disabling/enabling High Sound Alarm monitoring.

• Disabling/enabling AC Power monitoring.

• Activation of Listen-In Time.

• Activation of the Status Report.

To issue commands by telephone, first dial the number of theModel 1108 to access the Status Report. The Status Report willbe followed by the programmed Listen-In Time. If you remainon the telephone, the Status Report will be repeated, followedby a 10 second waiting period and hang-up. During this10 second waiting period, or at any time during the call, othercommands may by accessed by pressing any push button onthe telephone.

If a Security Code is in effect, the Model 1108 will prompt youwith: “Enter Security Code.” If no Security Code is set, then itwill say “O.K.”

• Enter your Security Code (4 digits) with the telephonepush buttons. If the code you enter is correct, theModel 1108 will respond: “OK.”

• If you enter the wrong Security Code, the Model 1108says,“Error. Have a good day,” and hangs up.

Page 88: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

76

Disabling/enabling inputs – If an input is set to detect an alertcondition, it can be disabled to prevent the Model 1108 fromdialing out, or re-enabled at any time.

This feature allows the convenience of disabling an input, evenif you are away from the site of the Model 1108. One suchapplication may involve an input programmed to detectunauthorized entry. You are in another locale, but must allowsomeone else temporary access to the area monitored by theModel 1108. Using a Touch-ToneTM telephone, you can disablethe appropriate input (thereby disabling any alarm dial-outresponse). The input remains disabled until you issue the samecommand, which effectively returns it to its former, enabledstate.

Press the following push-buttons on the Touch-ToneTM tele-phone to execute the desired command:

* (asterisk), 1

...equal to Sensor On/Off, for input 1. To re-enable theinput, repeat the same Touch-ToneTM button sequenceused for disabling.

* (asterisk), 2

...equal to Sensor On/Off for input 2, and so on, forinputs up to 8. To re-enable the input, repeat the sameTouch-ToneTM button sequence used for disabling.

Disabling/enabling High Sound Monitoring –

* (asterisk), 9

...equal to SENSOR ON/OFF for High Sound Alarmmonitoring. To re-enable High Sound Alarm, repeat thecommand.

Disabling/enabling AC Power –

* (asterisk), 0

...equal to Sensor On/Off for AC Power monitoring. Tore-enable AC Power monitoring , repeat the command.

Page 89: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

77

Chapter 6: Acknowledgment, Status Report, and Remote Access

Activating Listen-In Time –

# (pound), 1

...initiates Listen-In Time for listening to on-site soundsfor the programmed time available.

Activating Status Report –

# (pound), 2

...initiates a full recitation of the Status Report.

Exiting –

# (pound), # (pound)

...forces exit. The 1108 says, “Have a good day,” andhangs up.

Page 90: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

78

NOTES

Page 91: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 7: Operation

79

Chapter 7: Operation

After installation and programming is completed, theModel 1108 is fully operational. This chapter explains thesequence of events that occur during an alarm dialout toillustrate how the Model 1108 operates.

7.1 Alarm Detection, Dial-out and Acknowledgment

Generally, an alarm event is structured in the followingmanner:

I. The Model 1108 detects an alert condition due toa change at the sensor.

II. A valid alarm is recognized.

III. Dial-out begins.

IV. The alarm is acknowledged.

Often, an alarm does not proceed through all stages: either analert condition does not persist long enough to be consideredvalid, or a valid alarm is cancelled.

The table on the following page explains the alarm detection,dial-out and acknowledgment features and lists importantvariable factors affecting their operation.

Page 92: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

80

• Model 1108 detects a change in themonitored condition (from the sensorwired to one of the inputs). This isconsidered an alert condition, and doesnot qualify as a valid alarm at this point.

• The condition continues throughout theprogrammed Recognition Time. If thecondition (or sensor) reverts to itsnormal state before the RecognitionTime is reached, no alarm will occur.

• The condition must persist long enoughto meet or exceed the programmedRecognition Time. When RecognitionTime has expired, but the alert conditioncontinues, the Model 1108 willdetermine that a valid alarm exists.

• When a valid alarm is determined, CallDelay is activated, forcing theModel 1108 to wait for a programmedperiod of time before starting the dial-out process. Call Delay applies to theperiod just prior to dial-out, before thefirst telephone call is made.

• Call Delay provides the opportunity tocancel a valid alarm at the Model 1108’sinstallation site, before dial-out occurs.An audible voice message indicateswhich of the inputs is in alarm. If on-sitepersonnel acknowledge the alarm withinthe Call Delay time, theModel 1108 will not dial out. (LocalVoice Mute is disabled, so that alarmmessages can be heard at the site.)

I. Model 1108 Detects a Change at the Sensor

Variable FactorsII. A Valid Alarm Is Recognized

Variable Factors

Call Delay:Activated

Valid Alarm:Exists

Recognition Time:Expired

Local Voice Mute:Disabled

Alarm Message:Audible, On-siteActivated

Recognition Time:Activated

Input Type: (1) Anopen circuit closes,(2) a closed circuitopens, or(3) temperaturelimits are exceeded.

Page 93: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 7: Operation

81

• The dial-out process is activated as soonas the Call Delay time expires (if thealarm has not been cancelled at theModel 1108’s installation site.) The dial-out begins with telephone number 1 andproceeds sequentially, through theremaining telephone numbers.

• If the alarm is not acknowledged withthe first dial-out telephone call, theModel 1108 waits the duration ofIntercall Time before dialing the nexttelephone number. Intercall Time is theprogrammed waiting period in betweeneach dial-out telephone call.

• When the telephone is answered, theprogrammed Voice Repetitionsdetermine the number of times per callthe Model 1108 recites the alarmmessage.

• Call Progress, an automatic feature,enables the Model 1108 to detectwhether or not the telephone call isanswered. After 8 rings, or if a busysignal is encountered, the Model 1108will hang up, wait the programmedIntercall Time, and proceed to dial thenext telephone number.

• If no telephone calls are answered, theModel 1108 dials out sequentially,through the remaining telephonenumbers and continues to cycle until theprogrammed Maximum Number ofCalls is reached.

• When the telephone is answered, theModel 1108 will immediately beginreciting a message that indicates whichof the inputs is in alarm. At the sametime, the alarm message is repeating atthe Model 1108’s installation site. TheModel 1108 will request acknowledg-ment, if it has not yet occurred.

Alarm Messages:By TelephoneandOn-site

III. Dial-out Begins Variable Factors

Intercall Time:Activated

Voice Repetitions:Activated

Call Progress:Activated

Max Calls:Activated

Call Delay:Expired

Page 94: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

82

• At any time after a valid alarm isdetermined, the alarm may be acknowl-edged at the Model 1108’s installationsite, by pressing any key.

• When the Model 1108 dials out and thecall is answered via Touch-Tonetelephone, any alarm may be instantlyacknowledged by pressing “555.”

• If the alarm message repeats for thenumber of programmed Voice Repeti-tions, and “555” has not been entered,the Model 1108 will say:

“Indicate that you have received warningmessage.”

The Model 1108 waits 10 seconds forthe Touch-Tone code “555” to beentered. If the code is entered within 10seconds, it responds:

“Warning message received by telephonenumber...(the Unit ID Number).”

The alarm is considered acknowledgedand the dialout concludes.

• If the Model 1108 does not receive theTouch-Tone code within 10 seconds, itrecites the following and then hangs up:

“Dial telephone number (gives the Unit ID Number)within...(the programmed Intercall Time.)”

The recipient of this message must callthe Model 1108 back within the periodprogrammed for Intercall Time, in orderto acknowledge the alarm. If LocalVoice Mute is off, the unit will beep atthe installation site while waiting forthis call.

• Callback: The Model 1108 waits 10rings before answering to guard againstrandom acknowledgment. If ananswering device is connected to the

Local, On-site Acknowledgment

Variable FactorsIV. The Alarm is Acknowledged

Tone or PulseCallbackAcknowledgment:Within Intercall Time

Touch-ToneAcknowledgment:Normal Code 555

Touch-ToneAcknowledgment:Fast Code 555

Page 95: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Chapter 7: Operation

83

same line as the Model 1108 (and TADis enabled), the Model 1108 willanswer on the first ring. First, it recitesthe Status Report, followed by:

“Warning message received by telephonenumber...(the number of your present location).”“Have a good day.”

When the Model 1108 hangs up, thealarm is acknowledged and dial-outstops.

• If calls remain unanswered, or if theyare received by an answering machineor FAX, the Model 1108 continues thedialout sequence; it waits the IntercallTime and proceeds to dial the nexttelephone number. Telephone numbersare dialed sequentially, and this cyclecontinues for the number of Max Callsprogrammed. If no acknowledgmentoccurs, then at the completion of MaxCalls, the alarm is automaticallyacknowledged and the dial-out processis terminated.

Max CallsAcknowledgment

Tone or PulseCallbackAcknowledgment:TAD Enabled

IV. The Alarm is Acknowledged Variable Factors

NOTE

Acknowledging the alarm does not correct thesituation! The alarm condition will still exist untilthe sensor is restored to its normal state.

Page 96: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

84

7.2 Example: A Dial-out Telephone Call

The following parameters are selected for demonstrationpurposes:

• Model 1108 Unit ID Number is set to 555-5674.It is currently installed at your place of business.

• Dial-out Telephone Number 1 is programmedto 555-1234, your home telephone number.

• Voice Repetitions are set to 4.

The Model 1108 is detecting an alarm on input 2.The telephone rings at 555-1234, your home number.You answer the telephone and hear the following message:

“Hello, this is telephone number 555-5674. The time is 8.30 p.m. Alert condition two exists.”

(4-seconds to hear on-site sound from unit’s microphone.)

“Hello, this is telephone number 555-5674. The time is 8.30 p.m. Alert condition two exists.”

(4-seconds to hear on-site sound from unit’s microphone.)

“Hello, this is telephone number 555-5674. The time is 8.30 p.m. Alert condition two exists.”

(4-seconds to hear on-site sound from unit’s microphone.)

“Hello, this is telephone number 555-5674. The time is 8.30 p.m. Alert condition two exists.”

(4-seconds to hear on-site sound from unit’s microphone.)

“Indicate you have received warning message.”

NOTE

It is important that your dial-out telephonenumbers be answered by you or other authorizedpersonnel in order to ensure adequate response toan alarm.

Page 97: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix A: Troubleshooting

85

Appendix A: Troubleshooting

In the event that a problem is encountered, this section will assistyou in determining the cause, so you can return the unit to its usualmonitoring routine with minimal interruption.

Most problems with the Model 1108 are easy to identify andquickly corrected, and are found under the following generalheadings:

• Communications/dial-out functions

• Temperature monitoring

• Sound level monitoring

• Other monitoring functions

If you have tried the solutions outlined in this section and are notsatisfied with the results, call Customer Service, (610) 558-2700, orfollow the guidelines for shipping the Model 1108 to Phonetics forrepair (see Appendix C).

Page 98: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

86

Co

mm

un

icat

ion

s / D

ial-

ou

t:

Pro

ble

m

1.T

he M

odel

110

8 fa

ils to

dia

l out

.a)

The

tele

phon

e nu

mbe

r m

ay b

ein

corr

ectly

pro

gram

med

.

b)To

ne o

r pu

lse

(the

cur

rent

dia

ling

met

hod)

is n

ot c

ompa

tible

with

the

tele

phon

e lin

e on

whi

ch th

e M

odel

110

8is

inst

alle

d.

c)R

ecog

nitio

n T

ime

is to

o lo

ng. A

n al

ert

cond

ition

doe

s no

t rem

ain

in e

ffec

t lon

gen

ough

to b

ecom

e a

valid

ala

rm.

Cau

seS

olu

tio

n

Rec

heck

pro

gram

min

g st

eps,

Ref

er to

Cha

pter

4,

Sect

ion

4.2.

1.

Switc

h fr

om th

e cu

rren

t set

ting:

fro

m to

ne to

puls

e, o

r fr

om p

ulse

to to

ne. R

efer

toC

hapt

er 4

, Se

ctio

n 4.

3.

Rep

rogr

am R

ecog

nitio

n T

ime.

Set

the

Rec

ogni

tion

Tim

e to

the

min

imum

dur

atio

nre

quir

ed to

cre

ate

a va

lid a

larm

. If

poss

ible

,te

st th

e ne

w s

ettin

g by

del

iber

atel

y cr

eatin

gan

ale

rt c

ondi

tion.

Ref

er to

Cha

pter

5,

Sect

ion

5.3.

d) M

ax C

alls

is s

et to

zer

o.R

epro

gram

Max

Cal

ls.

It is

a g

ood

idea

tose

t you

r M

ax C

alls

to a

t lea

st e

qual

the

num

ber

of d

ial-

out t

elep

hone

num

bers

prog

ram

med

. Ref

er to

Cha

pter

4,

Sect

ion

4.12

.1.

Page 99: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix A: Troubleshooting

87

2.T

he M

odel

110

8 w

ill n

ot a

nsw

erth

e te

leph

one

whe

n ca

lled

for

aSt

atus

Rep

ort o

r al

arm

ackn

owle

dgm

ent.

The

Mod

el 1

108

mus

t be

conn

ecte

d to

ast

anda

rd (

2-w

ire

anal

og)

tele

phon

e lin

e, n

ota

digi

tal e

xten

sion

to a

pho

ne s

yste

m. I

f th

eun

it w

ill n

ot d

ial o

ut a

nd th

e fa

ctor

spr

evio

usly

list

ed h

ave

been

rul

ed o

ut, t

ryco

nnec

ting

the

unit

to a

sta

ndar

d re

side

ntia

lte

leph

one

line.

e)T

he M

odel

110

8 is

con

nect

ed to

an

inco

mpa

tible

tele

phon

e lin

e.

a)R

ings

Unt

il A

nsw

er is

inco

rrec

tlypr

ogra

mm

ed.

Rec

heck

pro

gram

min

g of

Rin

gs U

ntil

Ans

wer

. R

efer

to C

hapt

er 4

, Sec

tion

4.5.

1.

b)T

he M

odel

110

8 is

con

nect

ed to

an

inco

mpa

tible

tele

phon

e lin

e. S

ome

tele

phon

e sy

stem

s w

ill n

ot a

llow

the

tele

phon

e to

rin

g be

yond

4 r

ings

. If

your

Mod

el 1

108’

s R

ings

Unt

il A

nsw

er is

set

at

mor

e th

an 4

rin

gs, y

ou m

ay n

ot b

e ab

le to

acce

ss th

e un

it. T

ry s

ettin

g th

e R

ings

Unt

ilA

nsw

er to

less

than

4 r

ings

. If

this

doe

s no

tco

rrec

t the

pro

blem

, it m

ay in

dica

tete

leph

one

line

inco

mpa

tibili

ty. I

n th

is c

ase,

try

conn

ectin

g th

e M

odel

110

8 to

a s

tand

ard,

resi

dent

ial t

elep

hone

line

.

Page 100: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

88

Co

mm

un

icat

ion

s / D

ial-

ou

t:

Pro

ble

mS

olu

tio

nC

ause

6.T

he M

odel

110

8 an

d te

leph

one

answ

erin

g de

vice

(sh

arin

g th

esa

me

line)

ans

wer

inco

min

g ca

llssi

mul

tane

ousl

y.

The

Mod

el 1

108’

s nu

mbe

r of

Rin

gs U

ntil

Ans

wer

is s

et to

equ

al th

e nu

mbe

r of

rin

gsse

t for

the

tele

phon

e an

swer

ing

devi

ce.

Cha

nge

the

num

ber

of R

ings

Unt

il A

nsw

erfo

r th

e M

odel

110

8. R

efer

to C

hapt

er 4

,Se

ctio

n 4.

5.

5.T

he M

odel

110

8 di

als

out

corr

ectly

but

fai

ls to

aud

ibly

rec

iteits

ala

rm m

essa

ge w

hen

you

answ

er th

e ca

ll.

Voi

ce R

eps

is s

et to

zer

o.R

epro

gram

Voi

ce R

eps

to 1

or

grea

ter.

Ref

er to

Cha

pter

4, S

ectio

n 4.

10.

4.T

he M

odel

110

8 re

cite

s th

e al

arm

mes

sage

or

Stat

us R

epor

t ove

r th

ete

leph

one,

but

is s

ilent

at t

hein

stal

latio

n si

te.

The

loca

l voi

ce m

ute

feat

ure

is in

eff

ect.

Dea

ctiv

ate

loca

l voi

ce m

ute.

Ref

er to

the

prog

ram

min

g st

eps

in C

hapt

er 4

,Se

ctio

n 4.

9.

Whe

n ca

lling

the

Mod

el 1

108,

and

the

TAD

is d

isab

led,

allo

w th

e te

leph

one

to r

ing

10tim

es.

Ref

er to

Cha

pter

6, S

ectio

n 6.

1.3,

and

Cha

pter

4, S

ectio

n 4.

6.3.

You

did

not

allo

w th

e te

leph

one

to r

ing

10 ti

mes

. Not

e: I

f th

e TA

D (

tele

phon

ean

swer

ing

devi

ce)

is d

isab

led,

the

tele

phon

eri

ngs

ten

times

bef

ore

the

Mod

el 1

108

answ

ers.

If

the

TAD

is e

nabl

ed, t

hete

leph

one

ring

s on

ce b

efor

e th

e M

odel

110

8an

swer

s th

e ca

ll.

3.T

he M

odel

110

8 w

ill n

ot a

nsw

erth

e te

leph

one

for

Cal

lbac

kA

ckno

wle

dgem

ent.

(Con

tinue

d fr

om p

revi

ous

page

)

Page 101: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix A: Troubleshooting

89

The

tem

pera

ture

sen

sor

has

been

disc

onne

cted

or

has

brok

en w

ires

.2.

The

tem

pera

ture

rea

ding

is -

20° F

or -

30° C

.

Pro

ble

m

Tem

per

atu

re M

on

ito

rin

g:

Exa

min

e th

e w

ires

to te

mpe

ratu

re s

enso

r an

dco

nnec

t or

repl

ace

wir

ing.

Try

mov

ing

the

unit

to a

dif

fere

nt lo

catio

n.a)

Tem

pera

ture

sen

sing

may

be

affe

cted

by

a so

urce

of

ambi

ent h

eat (

ie.,

dire

ctsu

nlig

ht, o

r he

at d

uct p

roxi

mity

).

4.Te

mpe

ratu

re r

eadi

ng is

inac

cura

te.

3.Te

mpe

ratu

re r

eads

150

° F o

r 65

° C.

Tem

pera

ture

sen

sor

wir

es a

re to

uchi

ng o

rha

ve s

hort

ed.

Ver

ify

and

corr

ect w

irin

g.

b) T

empe

ratu

re m

ay r

equi

re c

alib

ratio

n.A

fter

mov

ing

or p

laci

ng th

e un

it aw

ay f

rom

ambi

ent h

eat s

ourc

es, t

he te

mpe

ratu

re m

aybe

cal

ibra

ted

to o

f fse

t ina

ccur

ate

norm

alre

adin

g by

sev

eral

deg

rees

. R

efer

toC

hapt

er 5

, Sec

tion

5.6.

Cau

seS

olu

tio

n

1.C

an’t

pro

gram

tem

pera

ture

lim

its;

or th

e un

it w

on’t

rea

d th

ete

mpe

ratu

re s

enso

r.

The

inpu

t isn

’ t c

onfi

gure

d to

rea

d a

tem

pera

ture

sen

sor.

Pres

s SE

T a

nd C

ON

FIG

UR

E to

pro

gram

the

inpu

t. (S

ee S

ectio

n 5.

1.1

for

mor

e in

form

a-tio

n on

con

figu

ring

inpu

ts.)

c) T

he u

nit i

s us

ing

the

wro

ng te

mpe

ratu

resc

ale

(Fah

renh

eit v

s. C

elsi

us).

Ver

ify

tem

pera

ture

sca

le. S

ee C

hapt

er 5

,Se

ctio

n 5.

5.

Page 102: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

90

Cau

se

So

un

d L

evel

Mo

nit

ori

ng

:

So

luti

on

Pro

ble

m

So

luti

on

Cau

seP

rob

lem

Oth

er M

on

ito

rin

g:

1.A

larm

sta

tus

of a

n al

ert i

nput

isin

corr

ect.

Rec

onfi

gure

the

inpu

t. S

eeC

hapt

er 5

,Sec

tion

5.1.

Inco

rrec

t inp

ut n

orm

ality

.

AC

pow

er is

oft

en s

ubje

ct to

bri

efin

terr

uptio

ns. T

o av

oid

freq

uent

, fal

seal

arm

s, in

crea

se t

he p

ower

Rec

ogni

tion

Tim

e. R

efer

to C

hapt

er 5

, Sec

tion

5.9.

Prog

ram

med

Rec

ogni

tion

Tim

e is

too

shor

t.2.

Fals

e po

wer

out

ala

rms

2.H

igh

soun

d do

es n

ot c

ause

an

alar

m.

Mov

e th

e un

it cl

oser

or

repr

ogra

m th

e so

und

sens

itivi

ty. R

efer

to C

hapt

er 5

, Sec

tion

5.10

.T

he u

nit i

s no

t clo

se e

noug

h to

the

high

soun

d so

urce

, or

the

prog

ram

med

sou

ndse

tting

res

ults

in a

lack

of

sens

itivi

ty to

hig

hso

und.

Rep

rogr

am th

e so

und

sens

itivi

ty.

Ref

er to

Cha

pter

5, S

ectio

n 5.

10.

The

pro

gram

med

sou

nd s

ensi

tivity

res

ults

inov

er-s

ensi

tivity

to n

on-a

larm

sou

nd a

s w

ell

as a

larm

sou

nd.

1.Fa

lse

high

sou

nd a

larm

s oc

cur

freq

uent

ly.

Soun

d R

ecog

nitio

n T

ime

is to

o sh

ort.

Len

gthe

n th

e so

und

Rec

ogni

tion

Tim

e.R

efer

to C

hapt

er 5

, Sec

tion

5.10

.

Page 103: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix A: Troubleshooting

91

b) R

ecog

nitio

n tim

e se

tting

is to

o lo

ng.

a)B

atte

ries

are

eith

er in

corr

ectly

inst

alle

dor

dra

ined

.3.

The

Mod

el 1

108

does

not

rec

og-

nize

pow

er f

ailu

re.

To v

erif

y pr

oper

bat

tery

fun

ctio

n, u

nplu

g th

eun

it an

d ve

rify

con

tinue

d op

erat

ion

usin

gba

tteri

es o

nly.

If

unit

ceas

es to

fun

ctio

n,fi

rst t

ry r

eins

talli

ng th

e ba

tteri

es.

If th

is is

not s

ucce

ssfu

l, r

epla

ce th

e ba

tteri

es.

Ref

erto

Cha

pter

2, S

ectio

n 2.

4 fo

r co

mpl

ete

inst

ruct

ions

.

Rep

rogr

am R

ecog

nitio

n T

ime.

Set

the

Rec

ogni

tion

Tim

e to

the

min

imum

req

uire

dfo

r a

mon

itore

d co

nditi

on to

bec

ome

a va

lidal

arm

. If

poss

ible

, tes

t the

con

ditio

n by

delib

erat

ely

crea

ting

an a

lert

con

ditio

n.R

efer

to C

hapt

er 5

, Sec

tion

5.3.

a)In

puts

for

ala

rm a

re d

isab

led.

4.T

he M

odel

110

8 do

es n

otre

cogn

ize

any

alar

m.

Ena

ble

the

inpu

ts f

or a

larm

. R

efer

toC

hapt

er 5

, Sec

tion

5.2.

b)Pr

ogra

mm

ed R

ecog

nitio

n T

ime

is to

olo

ng.

Rep

rogr

am R

ecog

nitio

n T

ime.

Set

the

Rec

ogni

tion

Tim

e to

the

min

imum

req

uire

dbe

fore

a v

alid

ala

rm o

ccur

s. I

f po

ssib

le, t

est

the

cond

ition

by

delib

erat

ely

crea

ting

anal

ert c

ondi

tion.

Ref

er to

Cha

pter

5,

Sect

ion

5.9.

Page 104: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

92

Oth

er M

on

ito

rin

g:

Cau

seS

olu

tio

nP

rob

lem

1.T

he b

atte

ries

dra

in p

rem

atur

ely.

The

bat

teri

es w

ill ta

ke o

ver

pow

erin

g th

eun

it w

hen

the

AC

tran

sfor

mer

is u

nplu

gged

from

the

120

VA

C o

utle

t. W

hen

stor

ing

the

unit,

be

sure

to r

emov

e th

e ba

tteri

es. R

efer

to C

hapt

er 2

, Sec

tion

2.4.

Be

sure

to u

se a

lkal

ine

batte

ries

—do

not

use

rech

arge

able

nic

ad b

atte

ries

.

If th

e so

lutio

ns o

ffer

ed a

bove

do

not a

ppea

r to

cor

rect

the

prob

lem

, app

ly th

e fo

llow

ing

step

s, in

the

orde

r sh

own.

•R

emov

e th

e ba

tteri

es.

•U

nplu

g th

e un

it.

•W

ait o

ne m

inut

e fo

r th

e M

odel

110

8 to

com

plet

ely

pow

er d

own.

•Pl

ug in

the

unit'

s A

C a

dapt

or in

to a

sta

ndar

d 12

0 V

AC

out

let.

•R

epla

ce th

e ba

tteri

es.

•R

econ

figu

re th

e in

puts

. R

efer

to C

hapt

er 5

, Sec

tion

5.1.

Ref

er to

Cha

pter

2, I

nsta

llatio

n, f

or a

dditi

onal

info

rmat

ion

on b

atte

ries

and

inst

alla

tion

proc

edur

es.

The

uni

t’ s A

C tr

ansf

orm

er is

unp

lugg

ed o

rfo

r so

me

othe

r re

ason

, ful

l AC

pow

er is

not

avai

labl

e to

the

unit.

Page 105: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix B: Checking for Proper Operation

93

Appendix B: Checking your Sensaphonefor Proper Operation

We recommend that you test your Sensaphone weekly to besure it is functioning properly. This will ensure that when aproblem arises the Sensaphone will be ready to alert theappropriate personnel.

There are several tests that can be performed:

1) Call the unit and listen to the Status Report. This will testthe unit’s ability to answer the phone and speak a mes-sage. It will also verify that all of the inputs are readingproperly, the alarm conditions are OK, the electricity ison, the microphone is functioning, and the batteries areOK.

2) Create an alarm on each input and allow the unit tocontact all programmed telephone numbers. This willmake sure that the Sensaphone is programmed properly.It will also prepare personnel to respond appropriatelywhen they receive a call from the Sensaphone.

3) Test the batteries by unplugging the AC adapter andmaking sure that the Sensaphone continues to function.Press WHAT IS, then STATUS on the keypad, and listento the status report. Make sure the report states that “theelectricity is off” and “battery condition OK”. Keep theAC adapter unplugged so that a Power Failure alarmoccurs. Allow the unit to dial all programmed telephonenumbers while running on battery backup. Plug in the ACadapter after the unit has finished dialing all of thetelephone numbers.

4) If you are using your Sensaphone to listen for a smokealarm, then be sure to test the smoke alarm to make surethat the Sensaphone picks up the audible signal andtriggers a high-sound-level alarm. Allow the unit to dialall programmed telephone numbers.

Page 106: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

94

Page 107: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix C: Accessories

95

Appendix C

Accessories

The sensors listed below are available from Phonetics, andrepresent the most commonly used input devices. Other drycontact sensors, designed for more specialized applications,may also be used. Commercial or industrial electrical supplyhouses can provide devices to monitor virtually any condition.

PART NUMBER SENSOR / SWITCH

FGD-0006 Magnetic Reed Switch

FGD-0007 Passive Infra-Red Detector

FGD-0010 Accessory Hook-Up Wire

FGD-0013 Water Detection Sensor

FGD-0022 Temp° Alert

FGD-0023 ISOTEL Surge Protector

FGD-0027 Humidistat

FGD-0049 Smoke Detector with Built-in Relay

FGD-0100 Remote Temperature Sensor

FGD-0101 Weatherproof Temperature Probe

FGD-0200 Phonecell SX3e Cellular Phone

Page 108: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

96

NOTES

Page 109: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Appendix B: Accessories

97

Appendix D: Returning the Unit for Repair

In the event that the Model 1108 does not function properly, wesuggest that you do the following:

1) Record your observations regarding the Model 1108’smalfunction.

2) Call the Technical Service Department prior to sending the unit to Phonetics for repair.

If the unit must be sent to Phonetics for Servicing, please dothe following:

1) Unplug the AC power supply from the wall outlet, removethe batteries, and disconnect all sensors from the alertinputs.

2) Carefully pack the unit to avoid damage in transit. Usethe original container (if available) or a sturdy shippingbox.

3) You must include the following information to avoidshipping delays:

a) Your name, address and telephone number.

b) A note explaining the problem.

4) Ship your package to the address below:

SERVICE DEPARTMENT

PHONETICS INC.

901 TRYENS ROAD

ASTON, PA 19014

5) Ship prepaid and insured via UPS or US Mail to ensure atraceable shipment with recourse for damage or replace-ment.

Page 110: Absolute Automation Inc. - InsideCover · 2014-03-13 · Part 68: The Sensaphone ® Model 1108 complies with Part 68 of the FCC rules. On the back of the unit there is a label that

Sensaphone® Model 1108 User’s Manual

98

1 YEAR LIMITED WARRANTY

1. WARRANTOR: Dealer, Distributor, Manufacturer

2. ELEMENTS OF WARRANTY: This Product is warranted to be free fromdefects in materials and craftsmanship with only the limitations and exclu-sions set out below.

3. WARRANTY AND REMEDY: One-Year Warranty — In the event thatthe Product does not conform to this warranty at any time during the time ofone year from original purchase, warrantor will repair the defect and return itto you at no charge.This warranty shall terminate and be of no further effect at the time theProduct is (1) damaged by extraneous cause such as fire, water, lightning,etc. or not maintained as reasonable and necessary; (2) modified; (3)improperly installed; (4) repaired by someone other than warrantor; (5) usedin a manner or purpose for which the Product was not intended; or (6) soldby original purchaser.

WARRANTORS’ OBLIGATION UNDER THIS WARRANTY IS LIMITED TOREPAIR OR REPLACEMENT OF THE PRODUCT. THIS WARRANTYDOES NOT COVER PAYMENT OR PROVIDE FOR THE REIMBURSE-MENT OF PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES.

It must be clear that the warrantors are not insuring your premises orguaranteeing that there will not be damage to your person or property if youuse this Product. The warrantors shall not be liable under any circum-stances for damage to your person or property or some other person or thatperson’s property by reason of the sale of this product or its failure tooperate in the manner in which it is designed. The warrantors’ liability, ifany, shall be limited to the original cost of the Product. The warrantorsassume no liability for installation of the Product and/or interruptions of theservice due to strikes, riots, floods, fire, and/or any cause beyond Seller’scontrol.

4. PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: Inthe event that the Product does not conform to this warranty, the Productshould be shipped or delivered freight prepaid to a warrantor with evidenceof original purchase.

5. LEGAL REMEDIES: This warranty gives you specific legal rights, andyou may also have other rights which vary from state to state to the extentallowed by law expressly in lieu of any other express or implied warranty,condition, or guarantee.

Effective date 07/01/90