Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Product Data Sheet A part of the new PINNACLE family New! Ascent I/O Smart Distributed & Peer-to-Peer I/O – Wireless, Serial, and Ethernet/Internet Modular I/O for SCADA and DCS systems – cost-effective monitoring and control Distributed SCADA I/O and multi-way peer-to-peer ”I/O Mirroring” Integrated Pump/Setpoint Control (Ascent Combo) High-speed Ethernet and RS-232/485 Serial port standard Allen-Bradley (DF1) & Modicon (Modbus) protocol support Built-in LCD HMI for local setup and system test without computer User configurable web page HMI - built in Secure AES encrypted communications Built-in non-volatile totalizers, runtime meters, and rate computation Optional internal spread spectrum radio Store & Forward Repeater operation to extend radio range Low-power and smart power management for battery backed applications 3-year warranty on parts and labor Ascent Ascent Ascent Ascent – Smart distributed and peer-to- peer I/O for monitoring and remote control applications: Expand the I/O of a PLC or RTU, and add sites to a SCADA or DCS system at very low cost Save thousands of dollars of in-plant wiring with peer-to-peer wireless, serial, or Ethernet I/O. Eliminate costly PLCs, HMIs and programming where smart I/O with a built-in web HMI will do. Supported by most PLCs, RTUs & HMIs Supported by most PLCs, RTUs & HMIs Supported by most PLCs, RTUs & HMIs Supported by most PLCs, RTUs & HMIs Ascent can be used with all major PLCs, RTUs, and HMI software using Modbus TCP/IP, Modbus RTU or DF1 protocols. Peer Peer Peer Peer-to to to to-peer I/O Mirroring peer I/O Mirroring peer I/O Mirroring peer I/O Mirroring - Ascent Combo and DIO modules can be linked up “back-to-back” (up to 8 to 1) to exchange sensor and control signals over a secure two-way wireless link, external radio, modem (via RS-232/485 serial port), or Ethernet. Ascent I/O saves thousands of dollars in wiring and conduit costs. Wireless Store & Forward Wireless Store & Forward Wireless Store & Forward Wireless Store & Forward – Any Ascent I/O module can also serve as a repeater to extend the effective range of a wireless network. Local LCD HMI Local LCD HMI Local LCD HMI Local LCD HMI - View and force I/O, and make simple configuration changes without a computer! Web Page Web Page Web Page Web Page Configuration Configuration Configuration Configuration – Ascent I/O modules come ready to run, but can be customized with a standard web browser (like Windows Internet Explorer). No special software is required on your PC or laptop. Customizable User HMI Customizable User HMI Customizable User HMI Customizable User HMI – Need a simple low-cost user interface? Ascent I/O includes a simple web-page HMI to save you hundreds of dollars in PC-based software costs. Web page configuration is simple and done in just minutes without programming; just fill in the blanks. Remote Support Remote Support Remote Support Remote Support – Ascent I/O can be reconfigured and customized over a secure Ethernet or wireless link, eliminating costly field trips and improving customer support. I/O can be “forced” via a secure web page to facilitate remote troubleshooting. Low Power Low Power Low Power Low Power– DC powered Ascent I/O can be optimized for battery-backed wireless systems with multiple power-saver modes and send-on-exception operation. Smart I/O Functions Smart I/O Functions Smart I/O Functions Smart I/O Functions – Ascent I/O includes cost-saving built-in functions that eliminate programming, simplify field installation and increase versatility: Discrete Inputs Discrete Inputs Discrete Inputs Discrete Inputs - configurable filtering & debounce - non-volatile high-speed totalizers - non-volatile runtimes - rate calculation (period or interval) Discrete Outputs Discrete Outputs Discrete Outputs Discrete Outputs - duty cycle (PWM) pulse function - synchronized flash function Universal Universal Universal Universal Analog Analog Analog Analog Inputs Inputs Inputs Inputs - sensor support (TC, RTD, Thermistor) - configurable filtering/averaging - configurable totalization Setpoint/P Setpoint/P Setpoint/P Setpoint/Pump ump ump ump Control (Ascent Combo) Control (Ascent Combo) Control (Ascent Combo) Control (Ascent Combo) - DO relay control for each Analog Input - Duplex pump control w/alternation Communications Bridging Communications Bridging Communications Bridging Communications Bridging - Ethernet to Modbus and Generic Serial/radio (virtual serial port) - Radio to Serial Analog readings, as well as totalizers, runtimes and rates are internally scalable to engineering units. Users see actual levels, flows and temperatures. Rugged Reliability Rugged Reliability Rugged Reliability Rugged Reliability – Ascent I/O has an operating temp range of -40 C to 70 C, and is backed by an industry leading 3-year factory parts and labor warranty.

Upload: others

Post on 13-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change.

Product Data Sheet

A part of the new PPIINNNNAACCLLEE ffaammiillyy NNeeww!!

AAsscceenntt II//OO Smart Distributed & Peer-to-Peer I/O – Wireless, Serial, and Ethernet/Internet

� Modular I/O for SCADA and DCS systems – cost-effective monitoring and control � Distributed SCADA I/O and multi-way peer-to-peer ”I/O Mirroring” � Integrated Pump/Setpoint Control (Ascent Combo) � High-speed Ethernet and RS-232/485 Serial port standard � Allen-Bradley (DF1) & Modicon (Modbus) protocol support � Built-in LCD HMI for local setup and system test without computer � User configurable web page HMI - built in � Secure AES encrypted communications � Built-in non-volatile totalizers, runtime meters, and rate computation � Optional internal spread spectrum radio � Store & Forward Repeater operation to extend radio range � Low-power and smart power management for battery backed applications � 3-year warranty on parts and labor

AscentAscentAscentAscent – Smart distributed and peer-to-peer I/O for monitoring and remote control applications:

• Expand the I/O of a PLC or RTU, and add sites to a SCADA or DCS system at very low cost

• Save thousands of dollars of in-plant wiring with peer-to-peer wireless, serial, or Ethernet I/O.

• Eliminate costly PLCs, HMIs and programming where smart I/O with a built-in web HMI will do.

Supported by most PLCs, RTUs & HMIsSupported by most PLCs, RTUs & HMIsSupported by most PLCs, RTUs & HMIsSupported by most PLCs, RTUs & HMIs Ascent can be used with all major PLCs, RTUs, and HMI software using Modbus TCP/IP, Modbus RTU or DF1 protocols. PeerPeerPeerPeer----totototo----peer I/O Mirroring peer I/O Mirroring peer I/O Mirroring peer I/O Mirroring ---- Ascent Combo and DIO modules can be linked up “back-to-back” (up to 8 to 1) to exchange sensor and control signals over a secure two-way wireless link, external radio, modem (via RS-232/485 serial port), or Ethernet. Ascent I/O saves thousands of dollars in wiring and conduit costs. Wireless Store & ForwardWireless Store & ForwardWireless Store & ForwardWireless Store & Forward – Any Ascent I/O module can also serve as a repeater to extend the effective range of a wireless network.

Local LCD HMI Local LCD HMI Local LCD HMI Local LCD HMI ---- View and force I/O, and make simple configuration changes without a computer! Web Page Web Page Web Page Web Page ConfigurationConfigurationConfigurationConfiguration – Ascent I/O modules come ready to run, but can be customized with a standard web browser (like Windows Internet Explorer). No special software is required on your PC or laptop. Customizable User HMI Customizable User HMI Customizable User HMI Customizable User HMI – Need a simple low-cost user interface? Ascent I/O includes a simple web-page HMI to save you hundreds of dollars in PC-based software costs. Web page configuration is simple and done in just minutes without programming; just fill in the blanks. Remote SupportRemote SupportRemote SupportRemote Support – Ascent I/O can be reconfigured and customized over a secure Ethernet or wireless link, eliminating costly field trips and improving customer support. I/O can be “forced” via a secure web page to facilitate remote troubleshooting. Low PowerLow PowerLow PowerLow Power– DC powered Ascent I/O can be optimized for battery-backed wireless systems with multiple power-saver modes and send-on-exception operation. Smart I/O FunctionsSmart I/O FunctionsSmart I/O FunctionsSmart I/O Functions – Ascent I/O includes cost-saving built-in functions that eliminate

programming, simplify field installation and increase versatility:

Discrete InputsDiscrete InputsDiscrete InputsDiscrete Inputs - configurable filtering & debounce - non-volatile high-speed totalizers - non-volatile runtimes - rate calculation (period or interval)

Discrete OutputsDiscrete OutputsDiscrete OutputsDiscrete Outputs - duty cycle (PWM) pulse function - synchronized flash function

Universal Universal Universal Universal Analog Analog Analog Analog InputsInputsInputsInputs - sensor support (TC, RTD, Thermistor) - configurable filtering/averaging - configurable totalization

Setpoint/PSetpoint/PSetpoint/PSetpoint/Pump ump ump ump Control (Ascent Combo)Control (Ascent Combo)Control (Ascent Combo)Control (Ascent Combo) - DO relay control for each Analog Input - Duplex pump control w/alternation

Communications BridgingCommunications BridgingCommunications BridgingCommunications Bridging - Ethernet to Modbus and Generic Serial/radio (virtual serial port)

- Radio to Serial

Analog readings, as well as totalizers, runtimes and rates are internally scalable to engineering units. Users see actual levels, flows and temperatures.

Rugged ReliabilityRugged ReliabilityRugged ReliabilityRugged Reliability – Ascent I/O has an operating temp range of -40 C to 70 C, and is backed by an industry leading 3-year factory parts and labor warranty.

Page 2: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

Ethernet LAN or the Internet

One or more PC computers can access local web HMI pages in

any of the Ascent modules

RS-485RS-232

Modbus or DF1

HMI Terminal

Ethernet

Internet

Router

HMI

Computer

SCADA

PLC

Modbus or DF1 Serial I/O

Ethernet

Repeater

I/O and

Repeater

See all I/O information with

the built-in web HMI!

Ascent Ascent Ascent Ascent I/O I/O I/O I/O Modules in a SCADA Modules in a SCADA Modules in a SCADA Modules in a SCADA or DCS or DCS or DCS or DCS SystemSystemSystemSystem

Ascent I/O modules have independent Ethernet, Serial (RS-232 and RS-485) and internal radio (option) communications ports. The ports may be used simultaneously. For example, a local Modbus HMI terminal can be connected locally to an I/O module to show levels and flows on the door of the panel housing an Ascent module, while an HMI computer or PLC is talking to the Ascent module over an Ethernet or wireless link. To extend the effective range of a wireless network, Ascent modules can act as intelligent repeaters, using either the internal radios, or external radios connected to the serial port.

Ascent modules can also bridge communications between ports. In the diagram above, an HMI computer or SCADA PLC can talk to Modbus (serial) I/O modules via an Ethernet or wireless connection, or both, saving the cost of additional radios. Bridging is supported from Ethernet to serial, Ethernet to wireless, and serial to wireless.

Ascent Ascent Ascent Ascent I/O I/O I/O I/O Modules Modules Modules Modules “Mirroring”“Mirroring”“Mirroring”“Mirroring” I/OI/OI/OI/O over Ethernet, the Internet, over Ethernet, the Internet, over Ethernet, the Internet, over Ethernet, the Internet, or Wireless Linkor Wireless Linkor Wireless Linkor Wireless Link

Ascent I/O Combo and DIO modules can also be used in a peer-to-peer or “mirror-mode” configuration where 1 to 8 modules pass I/O information to a single Ascent module. Analog and Discrete inputs are “repeated” or mirrored as Analog and Discrete Outputs in both directions (2-way). In addition to I/O levels, all tag names, units, etc. as well as associated totalizer, rate and runtime measurements are available for display on the local LCD HMIs or by communications at either ends of the links. Mirroring works over Ethernet, the Internet, a wireless link, or via external modems or radios connected to the Ascent module serial ports.

Mirroring over an Ethernet network or the Internet Mirroring over a Wireless Network (with one node as a Repeater)

Page 3: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

ComboComboComboCombo Ascent ComboAscent ComboAscent ComboAscent Combo – a symmetrical mixture of analog and discrete I/O; ideal for peer-to-peer mirrored I/O as well as distributed I/O applications. In addition, the Ascent Combo module has setpoint control, duplex pump control and alarming capabilities, and the Universal Inputs may be internally “routed” to the analog outputs to function as up to 8 configurable signal conditioners/transmitters. 8 Un8 Un8 Un8 Universal Iiversal Iiversal Iiversal Inputsnputsnputsnputs are individually “soft” configurable through the built-in LCD or web page HMI; no switches or jumpers. Each input accepts standard process signals (mA, mV or V), measures resistance, and reads thermocouples, thermistors or RTD temperature sensors. Conversion speed and averaging are configurable on every input to optimize response times and noise rejection. Each input can be scaled to engineering units. 8 Analog Outputs8 Analog Outputs8 Analog Outputs8 Analog Outputs provide high-resolution 20mA outputs, or provide a voltage output when used with an external resistor. An internal 24v loop supply is independent of the supply voltage. 10 Discrete Inputs10 Discrete Inputs10 Discrete Inputs10 Discrete Inputs – rugged optically isolated inputs available in 12-24v or 120-240v configurations. Each input includes its own non-volatile 32-bit totalizers and runtime accumulators, for keeping track of total flow or machine cycles, and motor and pump runtimes. In addition, pulse rates are calculated on each input, either by measuring the number of pulses over time period, or measuring the interval between pulses (Rate = 1/Time). The method used depends on the input frequency range and the desired update rate and measurement resolution. All measurements can be scaled to engineering, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. 10 Discrete Outputs10 Discrete Outputs10 Discrete Outputs10 Discrete Outputs provide relay dry contacts with programmable flashing, precision one-shot pulse and PWM control. Ascent Combo I/O Module Specifications

Analog IAnalog IAnalog IAnalog Inputsnputsnputsnputs 8888 Resolution 16-bit (24-bit internal) Input/Sensor Types: 20mA, 0 to 2 Volts, +/-250 mV, Ohms, Thermocouple (Type J, K, T, E, R, S, B, N) Thermistor (10K, II & III), RTD 2 and 3-wire (10,100, 1K ohm) note: 3-wire RTDs require 2 inputs each Measurement Averaging Individually configurable by input; 1, 2, 4, 8, 16, 32 samples, “boxcar” technique Conversion Speed User configurable; 7.5 to 4000 samples per second, per 8 inputs Input Functions (each Input) Accumulator (integrate/totalize input with 1 to 255 sec sampling interval)

Analog OutputsAnalog OutputsAnalog OutputsAnalog Outputs 8888 Resolution/Type 16-bit , 0/4 to 20mA (voltage output with external resistor)

Discrete IDiscrete IDiscrete IDiscrete Inputsnputsnputsnputs 10101010 Type Optically Isolated Input Ranges Order as 12/24V (up to 30Vdc/Vac), or 120V/240V (up to 260Vac) Input Conditioning Programmable Filtering/Delay (0 to 65,535mS) Runtime 1 32-bit non-volatile timer per input, configurable to read in seconds, tenths of minutes and tenths of hours Totalizers 1 32-bit non-volatile high-speed counter per input, (5KHz Max.) Rate Measurement Dual mode (Sample Period or 1/frequency) 1 to 255 second sample period, 0 to 65,535mS (1/F measurement technique)

Discrete OutputsDiscrete OutputsDiscrete OutputsDiscrete Outputs 10101010 Type Relay contact, 3A max. per output Output Functions (each output) Flash (synchronized with other outputs) Pulse (one-shot) 1 to 65,535mS, PWM - programmable On/Off times – 1 to 65,535mS each

Page 4: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

UIUIUIUI----32323232 Ascent UIAscent UIAscent UIAscent UI----32323232 – providing 32 Universal Analog Inputs. Each of the inputs are individually “soft” configurable through the built-in LCD or web page HMI; no switches or jumpers. Each input can be scaled to engineering units, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. 32 32 32 32 Universal InputsUniversal InputsUniversal InputsUniversal Inputs, individually “soft” configurable through the built-in LCD or web page HMI - no switches or jumpers. Each input may be configured to accept standard process signals (mA, mV or V), resistance, or thermocouple, thermistor or RTD temperature sensor. Conversion speed and built-in box car averaging are also configurable by channel in order to optimize response times and noise rejection. This also helps to offload processing overhead from PLC or DCS systems. Each group of eight inputs can be sampled up to 4000 times per second for an aggregate maximum sampling rate of 16,000 readings per second across all 32 inputs! The high conversion speed combined with a high-speed Ethernet interface makes these modules ideal for large distributed control and monitoring systems. The ability to “talk” multiple industry standard protocols makes these modules a low-cost alternative to expensive PLC and DCS system analog input modules. Ascent UI-32 Universal input Module Specifications

Analog Analog Analog Analog IIIInputsnputsnputsnputs

Quantity 32

Resolution 16-bit (24-bit internal)

Input/Sensor Types: 20mA, 0 to 2 Volts, +/-250 mV, Ohms, Thermocouple (Type J, K, T, E, R, S, B, N)

Thermistor (10K, II & III), RTD 2 and 3-wire (10,100, 1K ohm) note: 3-wire RTDs require 2 inputs each

Measurement Averaging Individually configurable by input; 1, 2, 4, 8, 16, 32 samples, “boxcar” technique

Conversion Speed User configurable; 7.5 to 4000 samples per second, per 8 inputs

Input Functions (each Input) Accumulator (integrate/totalize input with 1 to 255 sec sampling interval)

Page 5: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

DIO DIO DIO DIO ---- 22/2222/2222/2222/22 Ascent DIOAscent DIOAscent DIOAscent DIO----22/2222/2222/2222/22 – a symmetrical mixture of discrete inputs and outputs; ideal for peer-to-peer mirrored I/O as well as distributed I/O applications. 22222222 Discrete InputsDiscrete InputsDiscrete InputsDiscrete Inputs – rugged optically isolated inputs available in 12-24v or 120-240v configurations. Each input includes its own non-volatile 32-bit totalizer for keeping track of total flow or machine cycles, and a non-volatile 32-bit runtime meter, to keep track of motor and pump runtimes. In addition, pulse rates are calculated on each input, either by measuring the number of pulses over time period, or measuring the interval between pulses (Rate = 1/Time). The method used depends on the input frequency range and the desired update rate and measurement resolution. All measurements can be scaled to engineering, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. 22222222 Discrete OutputsDiscrete OutputsDiscrete OutputsDiscrete Outputs provide relay dry contacts with programmable flashing, precision one-shot pulse and PWM control functions. The flashing function provides a synchronized flash output whose time period is programmable, but common to all flashing outputs. This is used primarily to operate flashing alarm indicators. Every output also supports a one-shot pulse function; each time the channel is activated, the output turns on for a precision length of time, and then turns off automatically. This type of operation is frequently used with motorized actuators to move them a prescribed distance, independent of communications latency. The outputs also support PWM (Pulse Width Modulated) operation, where the output toggles on and off for a precision period of time, and where each channels on and off time can be set independently. This operation is used for heater and metering pump controls, frequently as part of some closed loop control system. Ascent DIO 22/22 Input/Output Module Specifications

Discrete InputsDiscrete InputsDiscrete InputsDiscrete Inputs 22222222 Type Optically Isolated Input Ranges Order as 12/24V (up to 30Vdc/Vac), or 120V/240V (up to 260Vac) Input Conditioning Programmable Filtering/Delay (0 to 65,535mS) Runtime 1 32-bit non-volatile timer per input, configurable to read in seconds, tenths of minutes and tenths of hours Totalizers 1 32-bit non-volatile high-speed counter per input, (5KHz Max.) Rate Measurement Dual mode (Sample Period or 1/frequency) 1 to 255 second sample period 0 to 65,535mS (1/F measurement technique)

Discrete OutputsDiscrete OutputsDiscrete OutputsDiscrete Outputs 22222222 Type Relay contact, 3A max. per output Output Functions (each output) Flash (synchronized with other outputs) Pulse (one-shot) 1 to 65,535mS, PWM - programmable On/Off times – 1 to 65,535mS each

Page 6: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

DIDIDIDI ---- 44444444 Ascent DIAscent DIAscent DIAscent DI----44444444 – a Discrete Input module that provides an economical means of monitoring a large number of Discrete Input sensors at a location. Local processing offloads most realtime response constraints of communications without missing a single transition or accurately measuring rates and runtimes. 44444444 Discrete InputsDiscrete InputsDiscrete InputsDiscrete Inputs – rugged optically isolated inputs available in 12-24v or 120-240v configurations. Each input includes its own non-volatile 32-bit totalizer for keeping track of total flow or machine cycles, and a non-volatile 32-bit runtime meter, to keep track of motor and pump runtimes. In addition, pulse rates are calculated on each input, either by measuring the number of pulses over time period, or measuring the interval between pulses (Rate = 1/Time). The method used depends on the input frequency range and the desired update rate and measurement resolution. All measurements can be scaled to engineering, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI.

Ascent DI-44 Input Module Specifications

Discrete InputsDiscrete InputsDiscrete InputsDiscrete Inputs 44444444 Type Optically Isolated Input Ranges Order as 12/24V (up to 30Vdc/Vac), or 120V/240V (up to 260Vac) Input Conditioning Programmable Filtering/Delay (0 to 65,535mS) Runtime 1 32-bit non-volatile timer per input, configurable to read in seconds, tenths of minutes and tenths of hours Totalizers 1 32-bit non-volatile high-speed counter per input, (5KHz Max.) Rate Measurement Dual mode (Sample Period or 1/frequency) 1 to 255 second sample period 0 to 65,535mS (1/F measurement technique)

Page 7: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

2.4"

6.2"6.2"

AAsscceenntt II//OO – Common Specifications Communications, Networking & HMI

EthernetEthernetEthernetEthernet 10 BaseT Protocol support Modbus TCP (Slave), Modbus UDP (Slave), HTTP, ARP, SDX (ICL), Serial Port Forwarding to serial port or internal radio Security 128-bit AES encryption using SDX protocol Separate passwords on user and configuration web pages.

Serial PortSerial PortSerial PortSerial Port RS-232 and RS-485 Data rate 2400 baud to 115K baud Protocol support Modbus RTU Slave (Modicon), DF1 (Allen-Bradley), SDX (ICL), Store & Forward (Modbus & SDX) Security 128-bit AES encryption

Internal Radio Internal Radio Internal Radio Internal Radio (optional)(optional)(optional)(optional) Choice of 3 radios; Digi (Xtend), Freewave (MR2), or MDS (Transnet) Radio type 902MHz to 928MHz Spread Spectrum, frequency hopping, (plus MESH networking with Digi Xtend radio) Freewave Sensitivity: -108dBm (BER 10-6), 32-bit CRC, point to multipoint, network diagnostics, FGR-115 compatible MDS Sensitivity: -108dBm (BER 10-6), 16-bit CRC, point to multipoint, network diagnostics, Transnet compatible Digi/Maxstream Sensitivity: -110dBm @9600 baud, -100dBm @115K baud, point to multipoint & peer to peer, DigiMesh Modes of Operation: Point to multipoint (all models), peer to peerand mesh (Digi Xtend only) Output power 1Watt maximum (user settable down to 100mW) Data rate 115K or 9600 baud, over the air Antenna Connection: Reverse polarity SMA Protocol support Modbus RTU Slave (Modicon), DF1 (Allen-Bradley), SDX (ICL), Store & Forward (Modbus & SDX) Security 256-bit AES encryption on all over-the-air messaging, plus128-bit AES encryption on SDX messages

Local HMI Local HMI Local HMI Local HMI Display:122x32 Graphic LCD w/backlight (4 lines x 20 characters max. in character mode) Input: 5 Axis navigation Switch plus “Escape” pushbutton switch

Web HMIWeb HMIWeb HMIWeb HMI HTML web pages; separate security access for configuration and users General

Watchdog TimersWatchdog TimersWatchdog TimersWatchdog Timers Communications (individually configurable by port). Resets outputs to individually user defined states.

CPU – Ensures “sanity” of internal processor operation

Terminal BlocksTerminal BlocksTerminal BlocksTerminal Blocks Removable, 3.5mm (0.138”), 12 to 22AWG, 15A/contact maximum

MountingMountingMountingMounting 35mm. DIN rail or panel mount

DimensionsDimensionsDimensionsDimensions 6.2”W x 6.2”H x 2.4”D (includes terminal blocks and elevation off panel on DIN rail)

EnvironmentEnvironmentEnvironmentEnvironment - 40ooooF(- 40ooooC) to 158ooooF (70 ooooC), 5%RH to 95% RH, non-condensing

PowerPowerPowerPower 10 to 30Vdc

Power consumption varies by module type, active outputs, and radio operation (internal radio option). With Ethernet OFF; 30mA typical. @ 12Vdc (Dos and AOs off), 400mA max. (radio transmit, maximum AOs/DOs ON) Ethernet ON (without radio): 100mA typical. @ 12Vdc (Dos and AOs off), 500mA max. @ 12Vdc (AOs/DOs ON)

WarrantyWarrantyWarrantyWarranty 3 years, factory parts and labor

Page 8: A part of the new PINNACLE family New! Ascent I/Ofiles.iclinks.com/datasheets/ascent/AscentFamilyDataSheet.pdfWireless Store & Forward Wireless Store & Forward – Any Ascent I/O module

AAsscceenntt II//OO

Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change. Rev 1.1a

For the perfect complement to the Ascent I/O modules . . . . . . check out the new Pinnacle family of programmable SCADA controllers.

Everest 300MHz 32-bit CPU, Real Time Clock/Calendar

128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 4 USB 5 Serial Ports (4 x RS-232, 1 x RS-232/RS-485) Optional internal radio and telephone modem

Base I/O: 8 Universal Analog inputs 1 Analog input / UPS Battery Input 4 Analog Outputs 4 Digital I/O (Low voltage & high-speed counters) 2 High-speed Pulse/Magnetic Pickup Inputs 20 Digital Inputs, Optically Isolated 12 Digital Outputs, Relay

Shasta 300MHz 32-bit CPU, Real Time Clock/Calendar

128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 2 USB 3 Serial Ports (2 x RS-232, 1 x RS-232/RS-485) Optional internal radio and telephone modem

Base I/O: 8 Universal Analog inputs 1 Analog input / UPS Battery Input 2 Analog Outputs 2 Digital I/O, Low voltage and Hgh-speed counters 1 High-speed Pulse/Magnetic Pickup Inputs 16 Digital Inputs, Optically Isolated 6 Digital Outputs, Relay

Rubicon 300MHz 32-bit CPU, Real Time Clock/Calendar

128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 2 USB 3 Serial Ports (2 x RS-232, 1 x RS-232/RS-485) Base I/O: 4 Universal Analog inputs 2 Analog Outputs 1 High-speed Pulse/Magnetic Pickup Inputs 20 Digital Inputs, Optically Isolated 10 Digital Outputs, Relay

Lassen 300MHz 32-bit CPU, Real Time Clock/Calendar

128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 2 USB

Base I/O: 2 Universal Analog inputs 1 Analog input 2 Analog Outputs 6 Digital Inputs, Low voltage and Hgh-speed counters 6 Digital I/O, Low voltage 1 High-speed Pulse/Magnetic Pickup Inputs