a full line of - philips · ivus tranducer pim connector y-connector transducer 8.2 f tip o.d....

2
Peripheral A full line of peripheral IVUS catheters to help guide your treatment strategies • % Stenosis • Calcium and thrombus • Real time vessel diameters • Length of stenosis • Dissection • Position of wire in true or false lumen • Location of side branches (without using contrast) • Completeness of treatment IVUS allows assessment of: Visions PV .035 catheter with centimeter markers 0.035” guide wire compatible 60 mm max imaging diameter Visions PV .014P RX catheter 0.014” guide wire compatible 20 mm max imaging diameter Visions PV .018 catheter 0.018” guide wire compatible 24 mm max imaging diameter Below the knee Choose your catheter based on imaging diameter and wire compatibility needed Subclavian artery Popliteal artery Renal artery Aorta and IVC Illiac vein and arteries Superficial femoral artery Pioneer Plus catheter 0.014” guide wire compatible 20 mm max imaging diameter

Upload: others

Post on 13-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A full line of - Philips · IVUS tranducer PIM connector Y-connector Transducer 8.2 F Tip O.D. ≤0.055 ” 90 cm working length Guide wire exit port ≤ 0.038" (0.97 mm) 30 cm GlyDx

PeripheralA full line of peripheral IVUS cathetersto help guide your treatment strategies

• % Stenosis

• Calcium and thrombus

• Real time vessel diameters

• Length of stenosis

• Dissection

• Position of wire in true or false lumen

• Location of side branches (without using contrast)

• Completeness of treatment

IVUS allows assessment of:

Visions PV .035 catheterwith centimeter markers

0.035” guide wire compatible 60 mm max imaging diameter

Visions PV .014P RX catheter

0.014” guide wire compatible 20 mm max imaging diameter

Visions PV .018 catheter

0.018” guide wire compatible 24 mm max imaging diameter

Below the knee

Choose your catheterbased on imaging diameter and wire compatibility needed

Subclavian artery

Popliteal artery

Renal artery

Aorta and IVC

Illiac vein and arteries

Superficial femoral artery

Pioneer Plus catheter

0.014” guide wire compatible 20 mm max imaging diameter

Page 2: A full line of - Philips · IVUS tranducer PIM connector Y-connector Transducer 8.2 F Tip O.D. ≤0.055 ” 90 cm working length Guide wire exit port ≤ 0.038" (0.97 mm) 30 cm GlyDx

Ordering information and technical specifications

Visions PV .035 catheter 88901

Min sheath: 8.5 F

PIM connector

Shaft markers Guide wire exit port≤ 0.018" (0.46 mm)

Transducer 3.5 F Tip O.D. 0.030”

135 cm

3.4 F

95 cm

31 cm

Visions PV .018 catheter 86700

Min sheath: 6 F

Visions PV .014P RX catheter 014R

Pioneer Plus catheter PPLUS120

Min sheath: 5 F

Min sheath: 6 F

PIM connector

Brachial and femoralshaft markers

Guide wireexit port≤ 0.014" (0.36 mm)

Transducer3.5 F

Tapered tipO.D. 0.019”

150 cm

3.3 F

100 cm

24 cm hydrophilic coating

Needle depth markers

Needle stop ring with lock

Needle deployment with autolock ring

Needle guide wire lumen

Connector for IVUS console

HandleExtended nitinol needle

IVUS tranducer

PIM connector

Y-connector Transducer 8.2 F

Tip O.D. ≤0.055”

90 cm working length

Guide wire exit port≤ 0.038" (0.97 mm)

30 cm GlyDx hydrophilic coating

25 RO markers 1 cm apart

1 cm 1 cm 1 cm

1 mm5 mm

12 mm

1.5 mmImaging plane

1 cm1 cm

6.5 mm1.5 mm

© 2017 Koninklijke Philips N.V. All rights reserved. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.600325-001/LDApproved for External Distribution