90 m.p.h. Wind Resistant Garage Door and Frame Installation Code Reference: DASMA Garage Door Wind Load Guide BASED ON THE 2000 / 2003 / 2006 INTERNATIONAL RESIDENTIAL CODES (IRC) Similar to other doors and windows, the design and installation of garage doors and frames shall comply with the design wind load for the structure. The basic wind speed for the Kansas City Metropolitan area is 90 mph (3-second gust). For urban and suburban areas, Exposure Category B, this wind speed translates into 12.8 psf positive wind pressure and 14.8 negative wind pressure for a 9’x7’ door; for larger doors the pressure exerted is 12.4 psf positive and 13.8 psf negative. Exposure B can be assumed unless the site meets the definition of another category (RE: IRC Section R301.2.1.4) One means of establishing that the door is code compliant is through labeling. The trade asso- ciation known as the Door and Access Systems Manufacturers Association International (DASMA) has a certified labeling program. The label that DASMA allows t be affixed to the door clearly indicates the wind speed (in psf) for which the door has been certified. Form more information on this program see DASMA’s web side at: www.dasma.com Also see DASMA Technical Data Sheet #155 for an overview of the IRC requirements. Garage doors are usually the largest openings in a house, and their failure in strong winds can lead to partial collapse of the house. Installation Procedures - Installation shall comply with the attached diagrams (Figures 1, 2, 3, and 4). The door and track installation shall comply with the attached diagrams or the manufacturers installation instructions, whichever is most restrictive. Inspection Procedures - Door and frame installation shall be verified for compliance prior to final inspection. • A copy of the manufacturers installation instructions shall be attached to the back of the garage door. • The installer shall attach a certification label to the door indicating compliance with the wind 90 mph wind load conditions and that the installation conforms to the manufactur- ers installation instructions.

Upload: nguyenthien

Post on 29-Aug-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings

90 m.p.h. Wind Resistant Garage Door and Frame Installation Code Reference: DASMA Garage Door Wind Load Guide BASED ON THE 2000 / 2003 / 2006 INTERNATIONAL RESIDENTIAL CODES (IRC) Similar to other doors and windows, the design and installation of garage doors and frames shall comply with the design wind load for the structure. The basic wind speed for the Kansas City Metropolitan area is 90 mph (3-second gust). For urban and suburban areas, Exposure Category B, this wind speed translates into 12.8 psf positive wind pressure and 14.8 negative wind pressure for a 9’x7’ door; for larger doors the pressure exerted is 12.4 psf positive and 13.8 psf negative. Exposure B can be assumed unless the site meets the definition of another category (RE: IRC Section R301.2.1.4) One means of establishing that the door is code compliant is through labeling. The trade asso-ciation known as the Door and Access Systems Manufacturers Association International (DASMA) has a certified labeling program. The label that DASMA allows t be affixed to the door clearly indicates the wind speed (in psf) for which the door has been certified. Form more information on this program see DASMA’s web side at: www.dasma.com Also see DASMA Technical Data Sheet #155 for an overview of the IRC requirements. Garage doors are usually the largest openings in a house, and their failure in strong winds can lead to partial collapse of the house. Installation Procedures - Installation shall comply with the attached diagrams (Figures 1, 2, 3, and 4). The door and track installation shall comply with the attached diagrams or the manufacturers installation instructions, whichever is most restrictive. Inspection Procedures - Door and frame installation shall be verified for compliance prior to final inspection.

• A copy of the manufacturers installation instructions shall be attached to the back of the garage door.

• The installer shall attach a certification label to the door indicating compliance with the wind 90 mph wind load conditions and that the installation conforms to the manufactur-ers installation instructions.

Page 2: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings

10’

No

te: F

or

clar

ity,1

00

0 lb

. h

ead

er-t

o-ja

ck s

trap

on

b

oth

sid

es o

f op

enin

g

un

-d

er 2

x 6

H fr

ame,

no

t sh

ow

n ,

Ref.

No

. LST

A2

4

Page 3: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings

10’

No

te: F

or

clar

ity,1

00

0 lb

. h

ead

er-t

o-ja

ck s

trap

on

b

oth

sid

es o

f op

enin

g

u

nd

er 2

x 6

H fr

ame,

no

t sh

ow

n ,

Ref.

No

. LST

A2

4

Page 4: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings
Page 5: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings
Page 6: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings

8/8/01 Rev. 3/08 Page 1 of 2 This sheet is reviewed periodically and may be updated. Visit www.dasma.com

DASMA GARAGE DOOR WIND LOAD GUI

BASED ON THE 2000 / 2003 / 2006 INTERNATIONAL RESIDENTIA

DASMA (the Door & Access Systems Manufacturers Association) has created a GARAGE DOGUIDE based on the 2000, 2003* and 2006 International Residential Codes wind load requireintended to be used by code officials, engineers, architects, builders, owners, insurance companparties. The Wind Load Guide also references a DASMA test procedure (ANSI/DASMA 108)manufacturers to determine structural load performance of a garage door. The guide is published by the Commercial & Residential Garage Door Division of DASMA, westimated 95% of all sectional garage doors sold in the United States. The Division’s Technicatechnical talent in the garage door industry, developed these tables based on the latest civil engcode criteria. The DASMA members believe the DASMA GARAGE DOOR WIND LOAD GUIDE will impthe issues related to garage doors and wind loads. DASMA continues to monitor developmentand the building codes in general, and continues to develop solutions to problems which affectindustry. Please contact DASMA for any questions or comments. 1Wind Loads for the Garage Door Wind Load Guide were calculated using the following variafollowing referenced sections, found in the 2000, 2003 and 2006 International Residential Cod

• Basic Wind Speed Map based on 3 Second Peak Gust – Figure R-301.2d • Equivalent Basic Wind Speeds, i.e. Fastest Mile vs. 3 Second Peak Gust – Table R-301.2.1.3 • Height and Exposure Adjustment Coefficients – Table R-301.2c • Components and Cladding Loads – Table R-301.2b

* Wind load provisions in the 2003 IRC are technically equivalent to those in the 2

#155m

for the latest version.

DE L CODES (IRC)

OR WIND LOAD ments1. The guide is ies and other interested , which may be used by

hich represents an l Committee, the best ineering and building

rove understanding of s regarding wind loads the garage door

bles, and were based on the es:

000 IRC

Page 7: 90 m.p.h. Wind Resistant Garage Door and Frame Installation mph... · 90 m.p.h. Wind Resistant Garage Door and Frame Installation ... Garage doors are usually the largest openings

8/8/01 Rev. 3/08 Page 2 of 2 This sheet is reviewed periodically and may be updated. Visit www.dasma.com for the latest version.

#155m GARAGE DOOR WIND LOAD GUIDE

BASED ON THE 2000 / 2003 / 2006 INTERNATIONAL RESIDENTIAL CODES, EXPOSURE B

Mean Roof Height

Door Size 90 MPH 100 MPH 110 MPH 120 MPH 130 MPH 140 MPH 150 MPH

Single 12.8 15.9 19.2 22.9 26.9 31.2 35.7 9’ x 7’ -14.8 -18.2 -22.0 -26.3 -30.8 -35.8 -41.0 Double 12.4 15.3 18.5 22.0 25.9 30.0 34.4

15 Feet Single Story

16’ x 7’ -13.8 -17.0 -20.7 -24.5 -28.8 -33.5 -38.3

Single 12.8 15.9 19.2 22.9 26.9 31.2 35.7 9’ x 7’ -14.8 -18.2 -22.0 -26.3 -30.8 -35.8 -41.0 Double 12.4 15.3 18.5 22.0 25.9 30.0 34.4

25 Feet Double Story

16’ x 7’ -13.8 -17.0 -20.7 -24.5 -28.8 -33.5 -38.3 Design pressures above are in Pounds per Square Foot (PSF)

Testing, if required by local authority, may be performed to ASTM E-330, or preferably ANSI/DASMA 108, with acceptance criteria in accordance with ANSI/DASMA 108.

Test conditions:

1. Garage doors shall be tested to both negative and positive pressures. Doors shall be installed simulating normal conditions (i.e., top roller in track radius, other rollers in tracks, all hinges in place, reinforcing hardware in place)

2. Test durations for each test direction shall be as follows: A. 10 seconds at design pressure. B. 10 seconds at 1.5 times the design pressure.

Standard engineering principles may be used to interpolate or extrapolate test results to door sizes not specifically tested. Doors shall include a manufacturer’s label certifying compliance to specific load.

This guide is provided for reference purposes only. In all cases the local building authority is the sole and final determiner of the structural and safety requirements, and suitability of the garage door.

Notes:

• Basic Wind Speeds above are three second peak-gust values • Doors larger than 100 square feet should use the 16 x 7 loads. Doors less than 100 square feet may be interpolated.

• Negative pressures assume door has 2 feet of width in building’s end zone. • Garage doors evaluated as Components and Cladding • Garage doors evaluated as attached to enclosed buildings with a Use Factor of 1.0. • Installation details vary. Consult manufacturer’s instructions. • Single Story Buildings: Multiply table values by 1.21 to obtain Exposure C values and by 1.47 to obtain Exposure D values • Double Story Buildings: Multiply table values by 1.35 to obtain Exposure C values and by 1.61 to obtain Exposure D values