Altistart  ®  48 Quick Reference Guide 8636HO0501 3/2005 Altistart 48 rdY ESC ENT TeD R KEYPAD OPERATION 3-character, 7-segment display Enters a menu or a parameter, or saves the displayed parameter or value Returns to the previous menu or parameter, or increases the displayed value Exits a menu or parameter, or aborts the displayed value to return to the previous value in the memory Advances to the next menu or parameter, or decreases the displayed value NOTE: Pressing or does not store the choices. To store the displayed choice, press .The display flashes when a value is stored. ENT SEt ESC ENT ACC ESC ENT 015 tq0 026 026 ESC ENT The display flashes when a value is stored. Some functions may require pressing the ENT button for two seconds to store the parameter change. ACCESS TO PARAMETERS Menu Parameter Value or assignment Next parameter Browsing within the menus 1 flash (stored) INTRODUCTION This reference guide provides a brief overview of the Altistart  ®  48 (ATS48) soft start controllers' keypad—describing its operation, how to access menus and parameters, as well as defining fault codes. Refer to the ATS48 Soft Start Installation Guide (30072-450-61_) for complete soft start installation and programming instructions. For a list of general guidelines to troubleshoot the soft start based on the fault code displayed on its keypad, refer to the maintenance, troubleshooting, and repair section of the ATS48 installation guide. XXX SEt PrO drC IO St2 COP SUP ESC ENT ESC ESC ENT ESC ESC ENT ESC ESC ENT ESC ESC ENT ESC ESC ENT ESC ESC ENT ESC Menus Power-up Displays soft start status ACCESS TO MENUS Settings Protection Advanced settings Control I/O Assignments 2nd motor parameters Communications Selected parameter displayed & locking code Altistart 48 Family ATS48D•••• ATS48C•••• ATS48M•••• Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineerin g.com

Upload: jose-luna

Post on 01-Jun-2018

236 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 8636 Ho 0501

8/9/2019 8636 Ho 0501

http://slidepdf.com/reader/full/8636-ho-0501 1/2

Altistart ® 48 Quick Reference Guide8636HO0501

3/200

Altistart 4 8

rdY

ESC ENT

Te DR

KEYPAD OPERATION

3-character, 7-segment display

Enters a menu or a parameter,or saves the displayedparameter or value

Returns to the previousmenu or parameter, orincreases the displayedvalue

Exits a menu or parameter, or aborts the displayedvalue to return to the previous value in the memory

Advances to the next menuor parameter, or decreasesthe displayed value

NOTE: Pressing or does not store the choices. To store the displayed choice, press . The display flashes when a value is stored.

ENT

SEtESC

ENT

ACCESC

ENT

015

tq0 026 026

ESC

ENT

The display flashes when a value isstored. Some functions may requirepressing the ENT button for twoseconds to store the parameter change.

ACCESS TO PARAMETERS

Menu

Parameter Value or assignment

Next parameter

Browsing within themenus

1 flash(stored)

INTRODUCTION

This reference guide provides a brief overview of the Altistart ® 48 (ATS48) soft startcontrollers' keypad—describing its operation, how to access menus and parameters, aswell as defining fault codes.

Refer to the ATS48 Soft Start Installation Guide (30072-450-61_) for complete soft startinstallation and programming instructions. For a list of general guidelines to troubleshootthe soft start based on the fault code displayed on its keypad, refer to the maintenance,troubleshooting, and repair section of the ATS48 installation guide.

XXX

SEt

PrO

drC

IO

St2

COP

SUP

ESC

ENT

ESC

ESC

ENT

ESC

ESC

ENT

ESC

ESC

ENT

ESC

ESC

ENT

ESC

ESC

ENT

ESC

ESC

ENT

ESC

Menus

Power-up

Displays soft start status

ACCESS TO MENUS

Settings

Protection

Advanced settings

Control I/O Assignments

2nd motor parameters

Communications

Selected parameter displayed& locking code

Altistart 48 Family

ATS48D••••ATS48C••••ATS48M••••

ourtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 2: 8636 Ho 0501

8/9/2019 8636 Ho 0501

http://slidepdf.com/reader/full/8636-ho-0501 2/2

8636HO0501Altistart ® 48 Quick Reference Guide 3/2005

Schneider Electric USA8001 Hwy 64 EastKnightdale, NC 275451-888-SquareD (1-888-778-2733) / www.us.SquareD.com

Electrical equipment should be installed, operated, serviced,and maintained only by qualified personnel. No responsibilityis assumed by Schneider Electric for any consequencesarising out of the use of this material.

© 2005 Schneider Electric All Rights Reserved

SEt- BASIC SETTINGS MenuParameter Code Factory SettingNominal motor currentCurrent limitAcceleration ramp timeInitial starting torqueType of stopDeceleration ramp timeFinal deceleration torqueImpulse braking torque levelDC injection braking time

InILtACCt90StydECEdCbrCEbA

Varies w/rating, A400% of In15 s20%-F- (Freewheel Stop)15 s20%50%20%

PrO- PROTECTION MenuParameter Code Factory SettingMotor overload protectionActivation of motor underloadMotor underload thresholdMotor underload timeExcessive starting timeActivation of current overloadCurrent overload thresholdCurrent overload timeLine phase reversal protectTime before restartingPhase loss thresholdMotor-monitoring PTC probesAutomatic restartReset motor thermal state

tHPULLLULtULtLSOILLOCtOLPHrtbSPHLPtCArSrtH

class 10OFF60%60 sOFFOFF80%10 sno2 s10%OFFOFFno

drC- ADVANCED SETTINGS MenuParameter Code Factory SettingTorque limitVoltage boost levelTest on small motorTorque controlStator loss compensationDeceleration gainCascade function activationLine voltageLine frequencyReset kWh/elapsed timeReturn to factory settings

tLIbStSStCLPLSCtIGCSCULnFrCrPrFCS

OFFOFFOFFON50%40 %OFF460 VAUt (Automatic)nono

I-O- I/O Control Terminal Settings MenuParameter Code Factory SettingLogic inputs

Preheating levelTime delay before preheatingLogic outputs

Relay R1Relay R2Relay R3Analog outputConfig. of analog outputScaling of analog output

L13L14IPrtPrLO1

LO2r1r2r3AO04ASC

LIA(Freewheel Stop)LIL(Forced Local)0%5 min.tAl(Motor ThermalAlarm)rnl (Motor Powered)r1F (Fault Relay)(end of start)rnl (Motor Powered)OCr(Motor Current)020 (0–20 mA)200%

St2- 2ND MOTOR PARAMETERS MenuParameter Code Factory SettingNominal motor currentCurrent limitAcceleration ramp timeInitial starting torqueDeceleration ramp timeFinal deceleration torqueTorque limitDeceleration gain

In2IL2AC2t92dE2Ed2tL2tI2

Varies w/rating, A400% of In215 s

20%15 s20%OFF40%

COP- COMMUNICATIONS MenuParameter Code Factory SettingSoft start addressCommunicaiton speedCommunication formatSerial link timeout settingRestore remote keypaddisplay

AddtbrFOrtLPPCt

019.28n15 sOFF

SUP- PARAMETER DISPLAYED MenuParameter Code UnitPower factorMotor themal stateMotor currentElapsed operating timeActive powerActive power in kWMotor torqueDisplay of current stateLast detected faultPhase rotation directionKeypad display locking code

COStHrLCrrntLPrLAPLtrEtALFtPHECOd

0.01%A or kAh or kh%kW%

TROUBLESHOOTING

Fault Code Description

nLPrdY

Soft start without run command and:

• Line power not supplied• Line power supplied

tbS Starting time delay not elapsed

HEA Motor preheating in progress

(Use SUP menu to set up monitoringparameter. Factory setting: Motor Current.) Soft start with run command

brL Soft start braking

Stb Waiting for a command (RUN or STOP) incascade mode

CFF Invalid configuration on power-up

CFI Invalid configuration

CLF Loss of Control Power

EEF Internal memory fault

EtF External fault

FrF Line frequency out of tolerance

InF Internal fault

LrF Locked rotor fault

OCF Overcurrent fault

OHF Soft start overheating fault

OLC Current overload fault

OLF Motor overload/ground fault

OtF Motor thermal fault detected by PTC probesPHF Loss of line or motor phase

PIF Phase reversal fault

SLF Serial link fault

StF Excessive starting time

ULF Motor underload fault

USF Lack of AC line power on a run command

NOTE: Please refer to the troubleshooting section of the ATS48 Soft Start Installation Guide (30072-450-61_) forcomplete installation and programming instructions.

ATS48C14Y Altistart Panel Mount Soft Startwith keypad in cover.

ourtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com