80 to 125ANew range of modular protection devices.

Page 2: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging
Page 3: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

Welcome tothe new 80-125A range from Hager

The new range of modular protection devices ranging from 80 to 125A re-enforces Hager’s commitment to new product development in protection solutions for OEMs and commercial buildings.

Especially designed to provide :• Protection as main incomer for sub distribution• Protection of loads directly supplied by a power DB

Offering benefits focussed on safety, ease of installation and user friendliness, this is another example of Hager’s continuous investment to develop products for the future.

New modular protectiondevices 80 to 125A• Single and multi-pole circuit breakers 80-100-125A ratings• RCD add-on-blocks in fixed and adjustable time delay and sensitivity versions.

1

Page 4: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

The new 80 to 125A range offers safe and easy installation.A new triple cage innovation terminal design improves the reliability of the termination. Also, the new range introduces ‘fast on’ cable terminals for auxiliary connection, adjustable RCD blocks and a lockable toggle.

“Fast on “ terminals

The connection of auxilliaries be-comes easy, thanks to the new ‘Fast on’ connection terminals provided on the top and bottom of the MCBs. This provides a quick and easy solution to feed auxiliaries such as shunt trip coil, UV release etc...

Capacity of connection :- 1,5 to 6 mm2

- maximum current 6 A

More safety, more performance and more flexibility in your installations

Secure connections...Over a period of time

Triple innovation patented by Hager.

The HM range of MCBs and add on blocks benefit from the new exclusive “cage connection”, with three major innovations.

1. Tightening compensation systemWhen first tightened, the cable is compressed with an optimal compression force. Over time the cable strands could move due to vibration or pulling effort.The tightening compensation system helps to correct the cable distortion. The force remainins constant and optimal on the terminal, avoiding any risk of bad connection.

2. Arch of reinforcementA reinforcement plate surrounds the terminal. The reduction in distortion en-sures the tightening force is ap-plied directly to the cable impro-ving connection reliability. Ter-minal allows a tightening torque more than 3,5Nm i.e. 350kg on the cable.

Ech. 2

1

2

3

2

3. Cable holding JawsSerrations on the terminal jaws improve grip on the cable, especially in case of strongpulling. Marks of jaws can bevisible on the cable after optimal tightening.

Page 5: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

Modular protection devices 80 to 125A

adjustable RCD add-on-block

The add-on blocks are available in fixed and adjustable versions. In adjustable version, thesensitivity and the time delay can be adjusted, even when connected.

- selection of sensitivity : 300 mA, 500 mA or 1 A

- selection of time delay :instant trips or time delay (60 to 150msec)

- sealable cover to protect settings.

Anti Omission Lock

The RCD Add on block is equip-ped with locating pins which helps to secure the tightening of the bottom terminals to the circuit breaker. The cover cannot be closed if the terminals are not tightened correctly

Quick assembly of the add-on-block

Across the range, the assembly of the add-on-block is carried out in three simple steps. 1. Assembly2. Connection 3. Locking

➁ ➂

3

Page 6: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

Easy mounting

The DIN rail clips of the circuit breaker unit and add-on-block facilitate its mounting. They are easily accessible and work with any type of screwdriver.

Well designed Label holders

The entire range is equipped with label holders for locating the circuit. Label identification can fit easily under the lever.

Lockable toggle The MCBs can lock in “OFF”position by the integrated locking facility on the toggle.

This lock allows inserting a 2,5 to 3,5mm plastic cable tie where you can fit a warning card ifnecessary. (delivered with each product)

Modular protection devices 80 to 125A

Respect for the environment was a prime virtue in the design and development of this range. The materials selected for the manufacturing of these products respect the provisions of the European Directive on the “limitation of the use of dangerous substances” (Directive N° 2002/05/CE “RoHS”).

The MCB design is innovative and can be distinguished by its low power loss (5.5w for 100A).

Eco-design and low thermal dissipation

4

Page 7: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

5

Miniature circuit breakers 80-125A

Thermal magnetic circuitbreakers

curves “C” - “D”

In 80 to 125 A

These circuit breakers are intended for the protection of thecircuits against overloads and short circuits.

Series HMC, HMD, HMF :

These circuit breakers areequipped with reinforced screw cages.

A label holder is integrated under the toggle to ensure the location of the product.

The “OFF” position is clearly shown by a green indicator below the toggle.

Suitable for isolation (according to IEC 60947-2) : the isolation of the circuit breakers is indica-ted by a green indicator on the toggle.

These circuit breakers have quick closing : fast and simultaneous closing of the contacts, independent of the handling speed. This increases the life of thecircuit breaker whatever the type of load.

M HMC curve “C” 15000 (IEC 60898-1)15 kA for 80 - 100 - 125 A :IEC 60947-2width 1.5 mod/pole

M HMD curve “D”15000 (IEC 60898-1)15 kA for 80 - 100 - 125 A :IEC 60947-2width 1.5 mod/pole

M HMF curve “C” 10000 (IEC 60898-1)10 kA for 80 - 100 - 125 A :IEC 60947-2width 1.5 mod/pole

Series HMC, HMD,

M Mounting capability : bistable DIN-rail latches (2 posi-tions) upstream and dowstreamfacilitate the mounting of the cir-cuit breakers on the DIN-rail.

M terminals with tighteningcompensation.These circuit breakers are equipped with screw cages with tightening compensation, (reinforcement cage cable holding jaws). Theseelements contribute to aneffective cable tightening over time.

M These circuit breakers are equipped with cable terminals of type “fast on” upstream and downstream to feed an auxiliary low voltage circuit (indicating lights, auxiliary control...)Max. current 6Amax. cable csa - 6 mm2

M lockable toggleMCB can be locked in “Off” po-sition by the integrated locking facility on the toggle.This lock allows to insert a 2,5-3,5mm plastic cable tie where you can fit a warning card if necessary and allows a safer working environment for all per-sonnel.

M RCD Add-on blocks, simple, quick, adjustable and fixed1. assembly2. connection3. lockingthe assembly of the add-on block is carried out very quickly and easily. Simple and fast : it is a Hager innovation. add-on blocks 125A are available in fixed version and adjustableversion.

Nominal voltage : 230/415 V ~calibration setting :30 °C(IEC 60898-1) insulation voltage: 500 V

Options :M auxiliary :- to visualise the state ON or OFF of the circuit breaker,- to ON/OFF remotely the circuit breaker

M locking mechanism

M terminal covers and phase separators

M RCD add-on blocks

Model Icc/Curve Accessories Fast-on Tightening Lockable Front product connection comp. system handle labelling

HMF 10kA / C YES NO NO NO YES

HMC / HMD 15kA / C, D YES YES YES YES YES

Page 8: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

6

HMF499T

HMF299T

HMF399T

Miniature circuit breakers 80-125AHMF : “C” 10000 - 10 kA

Curves ”C” 10000 (IEC 60898-1) 10 kA IEC 60947-2

In 80 to 125 A

Tripping curves :“C” magnetic setting between 5 and 10 In.

Use :residential, commercial and in-dustrial applications

Connection capacity :- 35mm2 flexible wire (50mm2 possible with some cableend-caps),- 70mm2 rigid wire

KEMA approved according to IEC 60898-1, 947-2 standards

Designation In / A Width in ❚17,5 mm

CatRef..

curveC

Circuit breakers 2 poles 80

100

125

3

3

3

HMF280T

HMF290T

HMF299T

HMF380T

HMF390T

HMF399T

Circuit breakers 3 poles 80

100

125

4,5

4,5

4,5

HMF480T

HMF490T

HMF499T

Circuit breakers 4 poles 80

100

125

6

6

6

Circuit breakers 1 pole 80

100

125

1,5

1,5

1,5

HMF180T

HMF190T

HMF199T

HMF199T

Page 9: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

7

HMC499T

HMC299T

HMC399T

Miniature circuit breakers 80-125A HMC : “C” 15000 - 15 kA

Curves ”C” 15000 (IEC 60898-1) 15 kA IEC 60947-2

In 80 to 125 A

Tripping curves :“C” magnetic setting between 5 and 10 In.

Use :residential, commercial and in-dustrial applications

Connection capacity :- 35mm2 flexible wire (50mm2 possible with some cableend-caps),- 70mm2 rigid wire

KEMA approved according to IEC 60898-1, 947-2 standards

Designation In / A Width in ❚17,5 mm

CatRef..

curveC

Circuit breakers 2 poles 80

100

125

3

3

3

HMC280T

HMC290T

HMC299T

HMC380T

HMC390T

HMC399T

Circuit breakers 3 poles 80

100

125

4,5

4,5

4,5

HMC480T

HMC490T

HMC499T

Circuit breakers 4 poles 80

100

125

6

6

6

HMC199T

Circuit breakers 1 pole 80

100

125

1,5

1,5

1,5

HMC180T

HMC190T

HMC199T

Page 10: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

8

Accessories for circuit breakers

MZN 130

MZN 131

Miniature circuit breakers 80-125AHMD : “D” 15000 - 15 kA

Designation In / A Width in ❚17,5 mm

Curve ”D” 15000 (IEC 60898-1) 15 kA IEC 60947-2

In 80 to 125 A

Tripping curve :“D” magnetic setting between 10 and 20 In.

Use :commercial and industrial applications

Connection capacity : - 35mm2 flexible wire (50mm2

possible with some cableend-caps)- 70mm2 rigid wire.

KEMA approved according to IEC 60898-1, 947-2 standards

CatRef.

CatRef.

MZN 130

Designation

Terminal covers/ screw cap Allows to cover connection terminals, screws of circuit breakers. The screw co-vers can be sealed.

Characteristics

Circuit breakers 2 poles 80

100

125

3

3

3

80

100

125

4,5

4,5

4,5

HMD280T

HMD290T

HMD299T

HMD380T

HMD390T

HMD399T

80

100

125

4,5

4,5

4,5

HMD480T

HMD490T

HMD499T

Circuit breakers 3 poles

Circuit breakers 4 poles

MZN 131Phase separator 1 set of 3 phase separators

Circuit breakers 1 poles 80

100

125

1,5

1,5

1,5

HMD180T

HMD190T

HMD199T

HMD499T

HMD299T

HMD399T

Page 11: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

9

Designation Description Width in ❚ Pack CatRef. 17.5mm qty.

auxiliary contacts 1NO +1NC allows remote 1/2 1 MZ2015A - 230V~. indication of main contact status.

auxiliary contacts CA allows remote indication 1/2 1 MZ202and alarm indication of main contact status. SD contact indicates a overcurrent (e.g. MCB tripped on overload or short circuit).

shunt trip allows remote tripping of the associated device. Operation of the coil is indicated by a flag on the product fascia 230V - 415Vac 1 1 MZ203 110V - 130Vdc 24 - 48Vac 1 1 MZ204 12 - 48Vdc

under voltage release allows MCB to be closed only when voltage is above 85% of Un. MCB will automatically trip when voltage falls to between 70-35% of Un. Operation of the coil is indicated by a flag on the product facia 230Vac 1 1 MZ206 48Vdc 1 1 MZ205

locking kit this allows locking of the device 2 MZN175for the toggle of the device. toggle in the on/off position. supplied without padlock. will accept two padlocks with hasps of 4.75mm diameter max.

All auxiliaries are common to both single and multi-pole 10kA circuit breakers and RCCBs

connection capacity:4mm2 flexible6mm2 rigid

Auxiliaries and accessories for devices -NB, NC, ND, 10kA MCBs and RCCBs

AI3_MZ000_T1_01

MZ203 + MZ201 + MZ201 + MZ202 + MCBMZ206 MZ201 MZ201 MZ201

13

14

21

22

91

92

93

94

C 1

C 2

D 1

D 2

U <

MZ201

MZ204

MZ205

MZN175

Page 12: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

adjustable 0,3 - 0,5 - 1 A 0 - 60 - 150 ms

RCD add-on blocks type AC for circuit breakers HMC, HMD, HMF

Designation In / A Width in ❚17,5 mm

Adjustable blocks :the setting is done by actua-ting the thumbwheel in front face. The setting thumbwheels are protected by a transparent seala-ble cover.

Dissassembly :the bistable latch (2 positions) faci-litate the assembly or dissassem-bly by the bottom of the “circuit breaker + block.”

These RCD add-on blocks exist in version AC and in version A-HI.

Version AC :the add-on blocks are protected against unexpected tripping caused by the transitory leakage currents : lightning, capacitive loading.

RCD add-on blocks for circuit breakers HMC, HMD, HMF.

Fixed :- high sensitivity 30 mAinstantaneous- low sensitivity 300 mA - ins-tantaneous.

Settings :- sensitivity IDn 0,3 - 0,5 - 1 A ...- delay Dt 0 - 60 -150 ms.

These devices are intended to be fixed on the right side of the circuit breakers to form differen-tial circuit breakers from 80 to 125A, two, three orfour-pole.

This “circuit breaker + block” ensures, in addition to the over-load and short circuit protection, the protection of the installations against the insulation defects (300mA and 1A) and the protec-tion of the people against the direct contacts (30mA) and indi-rect (300mA).

High Immunity :the products with “reinforced immunity” reduce the unexpected tripping when they protectequipment generating disturban-ces (micro-processing,electronic ballast,...)

The differential defect or earth fault is visualized by the rearmament handle of the block in low position (yellow colour). Test button for differential functioning check.

Tightening compensation cagesthese circuit breaker blocs areequipped with screw cages with tightening compensation,reinforcement arch and cableholding jaws. These elements contribute to an effectivetightening over time.

Connection capacity : - 35mm2 flexible connection (50I

possible with some terminals),- 70mm2 rigid connection.

Assembly and disassembly facilitated by the drawer assem-bly system. The terminal cover is dependent of the add-on block. It is provided with keying systems avoiding the omission of terminal tightening downs-tream of the circuit breaker. .

Nominal voltage : -15 +10 %2 poles : 230 Vthree and four-pole : 230/400 Vtest button : 230/400 V.

In conformity with the require-ments of the appendix G of the IEC 61009-1.In conformity with the require-ments of standardIEC 60947-2.

Ref.add-on blocks AC

Add-on blocks 2 poles2 P.P.

125

Sensitivityfixed / adjustableIDn

fixed30 mA

6 BDC 280E

125adjustable 0,3 - 0,5 - 1 A 0 - 60 - 150 ms

6 BTC 280E

Add-on blocks 3 poles3 P.P.

association circuit breaker + add-on block 4 poles adjustable

3

2

1

4

53

42

1

6

125 fixed30 mA

6 BDC 380E

125adjustable 0,3 - 0,5 - 1 A 0 - 60 - 150 ms

6 BTC 380E

Add-on blocks 4 poles4 P.P.

125 fixed30 mA

6 BDC 480E

125 fixed300 mA

6 BFC 480E

125 6 BTC 480E

BDC 480E

AI3_composant continue_T1_02

AI3_composant continue_T1_02

73

642

51

8

BTC 280E

10

Page 13: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

11

Designation Sensitivity Width in ❚ Pack CatRef. l∆n In/A 17.5mm qty. standard

30mA 63A 2 1 BD264

100mA 63A 2 1 BE264

300mA 63A 2 1 BF264

time delayed 100mA 63A 2 1 BN264

time delayed 300mA 63A 2 1 BP264

30mA 63A 3 1 BD464

100mA 63A 3 1 BE464

300mA 63A 3 1 BF464

time delayed 100mA 63A 3 1 BN464

time delayed 300mA 63A 3 1 BP464

Description These products provide earthfault protection when associated with the 10kA (types NB,NC,ND) range of MCBs. They are de-signed to be fitted to the right hand side of 2 and 4 pole MCBs and the completed unit provides protection against:- - overload- short circuit- earth faults

Technical data3 non adjustable sensitivities30, 100 & 300mA nominal voltage 230 - 400V protection against nuisancetripping.2 pole = 2 ❚ 4 pole = 3 ❚

BS EN 61009 appendix G

Selective (time delay) versions are available in 100 & 300mA

Connection capacity16mm2 flexible 25mm2 rigid

All devices have a test facility.

RCCB add-on blocks for MCB devices - NB, NC, ND

S

SS

SS

2 pole MCB and add on block showing unique sliding connection feature

2 pole RCCBadd-on blocks

4 pole RCCBadd-on blocks

Page 14: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

MCBs : HMD

Current limiting at 400 VMCB’s : HMC - HLF

Miniature Circuit breakers 125A

0,4 1 4 10 40 100 1000 10000 100000

0,0001

0,0004

0,001

0,004

0,01

0,04

0,1

0,4

10

40

100

400

1000

4000

10000

1

4

80 A

80 A, 100 A, 125 A

contraintes thermiques Disj. HMC

100 A125 A

0,4 1 4 10 40 100 1000 10000 100000

10

40

100

400

1000

4000

10000

1

4

80 A

80 A, 100 A, 125 A

contraintes thermiques Disj. HMC

100 A125 A

0,4 1 4 10 40 100 1000 10000 100000

0,0001

0,0004

0,001

0,004

0,01

0,04

0,1

0,4

10

40

100

400

1000

4000

10000

1

4

80 A

125 A

contraintes thermiques Disj. HMD

100 A125 A

80 A100 A

0,4 1 4 10 40 100 1000 10000 100000

10

40

100

400

1000

4000

10000

1

4

80 A

125 A

contraintes thermiques Disj. HMD

100 A125 A

80 A100 A

Short circuit limiting at 400 VMCB’s : HMC - HLF MCB’s : HMD

AI3_limit. C/C disj. HMB, HMC

100 500 50001000 10000 40000

100

1000

500

5000

10000

80 A, 100 A, 125 A

AI3_limit. C/C disj. HMD

100 500 50001000 10000 40000

100

1000

500

5000

10000

80 A, 100 A, 125 A

inte

nsity

in k

A2 s

Icc in A ➝

inte

nsity

in k

A2 s

Icc in A ➝

inte

nsity

in k

A ➝

inte

nsity

in k

A ➝

Icc en A ➝ Icc en A ➝

12

Page 15: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging

13

Page 16: 80 to 125A New range of modular protection devices. - Hagerdownload.hager.com/hagergroup.co.uk/files_download/Hager_Product... · The new range of modular protection devices ranging