7sj66_iec_61850_mapping_a1_us.pdf

138
C53000-L2640-C554-1 SIPROTEC Multifuction Protection 7SJ66 IEC61850 Mapping Preface Contents Basics 1 Mapping 2 Literature & Index

Upload: hung-cuong-pham

Post on 19-Aug-2015

229 views

Category:

Documents


3 download

TRANSCRIPT

C53000-L2640-C554-1SIPROTECMultifuction Protection7SJ 66IEC61850Mapping Preface Contents Basics 1 Mapping 2 Literature & IndexSiemens Aktiengesellschaft Order No.: C53000-L2640-C554-1Disclaimer of LiabilityWe have checked the text of this manual against the hardware and software described. However, deviations from the description can-not be completely ruled out, so that no liability can be accepted for any errors or omissions contained in the information given.The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We appreciate any suggestions for improvement.We reserve the right to make technical improvements without no-tice.Document Release V04.00.00 Edition 03.2014CopyrightCopyright Siemens AG 2014Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where ex-pressly permitted. Violations are liable for damages. All rights re-served, particularly for the purposes of patent application or trademark registration. Registered TrademarksSIPROTEC, SINAUT, SICAM and DIGSI are registered trademarks of Siemens AG. Other designations in this manual might be trade-marks whose use by third parties for their own purposes would in-fringe the rights of the owner. 3 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PrefacePurpose of this manualIn this Manual, you will find the General information about the effects of configuration of your device to the different Logical Nodes and DOIs Mapping of device relevant information to Logical Nodes as part of protocol IEC61850Target audienceThis manual is intended mainly for all persons who configure, parameterize and operate SIPROTEC Devices 7SJ 66Scope of validity of this ManualSIPROTEC 7SJ 66, Versions from 4.00 and higherStandardsThis document has been created according to the ISO 9001 quality standards.Further SupportIf you have questions about SIPROTEC IEC 61850 interface, please contact your Siemens sales representative. 4 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20145 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014Table of contents1 Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81.2 Effects of Configuration on the Logical Nodes. . . . . . . . . . . . . . . . . . . . . . . . . . . .101.2.1 Function parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101.2.2 Function parameters SIPROTEC 7SJ 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111.3 Allocation of Logical Nodes to Logical Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . .161.4 Logical Node LLN0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201.4.1 Logical Device PROT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201.4.2 Logical Devices MEAS, DR and EXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221.4.3 Logical Device CTRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231.5 DOI Behavior. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251.5.1 Logical Device PROT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251.5.2 Logical Devices MEAS, CTRL, DR and EXT. . . . . . . . . . . . . . . . . . . . . . . . . . .262 Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272.1 Device (LPHD1, CALH1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282.1.1 Error with a summary alarm and Alarm summary event . . . . . . . . . . . . . . . . . .292.2 Oscillographic Fault Records (RDRE1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2). . . . . . . . . . . . . . . . . .342.3.1 Overcurrent Protection 50, 51 PH (PTOC6, PTOC7, PTOC18, PTOC1). . . . .342.3.2 Overcurrent Protection 50N, 51N (PTOC8, PTOC9, PTOC2). . . . . . . . . . . . . .392.3.3 Overcurrent Protection 50N, 51N (PTRC2) . . . . . . . . . . . . . . . . . . . . . . . . . . . .432.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3) . . . . . . . . . . . . . . . .462.4.1 Directional Overcurrent Protection 67 (PTOC10, PTOC11, PTOC19, PTOC3) 462.4.2 Directional Overcurrent Protection 67N (PTOC12, PTOC13, PTOC20, PTOC4) 522.4.3 Directional Overcurrent Protection 67N (PTRC3) . . . . . . . . . . . . . . . . . . . . . . .572.5 Single-Phase Overcurrent Protection (PTOC16, PTOC17). . . . . . . . . . . . . . . . . .612.6 Voltage Protection 27, 59 (PTUVx, PTOVx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .642.6.1 Undervoltage Protection 27 (PTUV1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .642.6.2 Undervoltage Protection 27 (PTUV2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .662.6.3 Overvoltage Protection 59 (PTOV1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .682.6.4 Overvoltage Protection 59 (PTOV2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .692.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5) . . . . . . . . . . . . . .702.8 Motor Protection (PMSS1, PMRI1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .742.8.1 Motor Starting Protection 48 (PMSS1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .742.8.2 Motor Restart Inhibit 66 (PMRI1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .766 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.9 Load J am Protection (PMLJ 1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 772.10 Frequency protection 81 O/U(PTUFx, PTOFx). . . . . . . . . . . . . . . . . . . . . . . . . . . . 792.10.1 Frequency protection 81-1 U (PTUF1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 792.10.2 Frequency protection 81-2 U (PTUF2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 812.10.3 Frequency protection 81-3 U (PTUF3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 832.10.4 Frequency protection 81-4 U (PTUF4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 852.10.5 Frequency protection 81-1 O (PTOF1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 872.10.6 Frequency protection 81-2 O (PTOF2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 892.10.7 Frequency protection 81-3 O (PTOF3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 912.10.8 Frequency protection 81-4 O (PTOF4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 932.11 QV Protection 27/Q (PTUV9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 952.12 Thermal overload protection (PTTR1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 962.13 Ground Fault Protection 64, 50N(s), 51N(s) (PHIZ1, PSDEx) . . . . . . . . . . . . . . . . . 982.13.1 Ground Fault Protection 64 (PHIZ1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 982.13.2 Ground Fault Protection 50N(s) (PSDE1, PSDE2). . . . . . . . . . . . . . . . . . . . . . . 1032.13.3 51 N(s) (PSDE3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1062.14 Automatic Reclosing System 79 (RREC1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1082.15 Fault Locator (RFLO1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1102.16 Circuit breaker failure protection 50BF(RBRF1). . . . . . . . . . . . . . . . . . . . . . . . . . . . 1122.17 Synchronism and Voltage Check 25 (RSYNx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1142.18 Three-pole tripping 52 Breaker (XCBR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1172.19 Tripping Logic of the Entire Device (PTRC1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1212.20 Measurement (MMXU1, MSQI1, MMTR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1232.20.1 Measures (MMXU1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1232.20.2 Measured values, symmetrical components (MSQI1). . . . . . . . . . . . . . . . . . . . 1282.20.3 Power Metering (MMTR1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1303 Literature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133Basics 7 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014Basics 1ContentsThis chapter contains general information about the effects of device configuration on Logical Nodes and DOIs.1.1 General 81.2 Effects of Configuration on the Logical Nodes 101.3 Allocation of Logical Nodes to Logical Devices 161.4 Logical Node LLN0 201.5 DOI Behavior 25Basics 1.1 General8 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.1 GeneralThe protocol IEC 61850 was developed to define a standard that can be internationally employed for the transmission of power automation system data.This cross national standard enables an interoperability between automation systems and devices made by different manufacturers.7SJ 66x can be equipped with an Ethernet module via which the protocol IEC 61850 is interpreted. The configuration of the protocol and the integration of the device with redundant IEC 61850 interfaces in your network are performed via the configuration system DIGSI. Logical DevicesLD Logical Devices represent a functional structuring of the LN Logical Nodes of a SIPROTEC device. The following Logical Devices are present: Logical Device Protection PROT Logical Device Measurement MEAS Logical Device Disturbance Recorder DR Logical Device Control CTRL Logical Device Extended EXTEach LD contains LN LLN0 and LN LPHD1.The allocation of the Logical Nodes to the Logical Devices is listed in Chapter 1.3.NoteThe following definitions are taken mainly from standard IEC 61850, Technical Specification IEC TS 61850-2.Basics1.1 General9 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014Logical Node LNSmallest part of a function that exchanges data. A logical node is an object defined by its data and methods.Data object instance DOIA Data object is part of a logical node object representing specific information for example status of measurement. From an object-oriented point of view, a data object is an instance of a data class. Specific data classes carry the semantic within a logical node.Data attribute instance DAIA Data attribute defines the name (semantic), format, range of possible values, and representation of values while being communicated.Annunciation types via GOOSEGeneric Object Oriented Substation EventA GOOSE report enables high speed trip signals to be issued with a high probability of delivery.The following types of information can be configured via GOOSE. External single point indication O/O External single point indication I/O External double point indication External double point indication, fast External operational measured values External metered valuesBasics 1.2 Effects of Configuration on the Logical Nodes10 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.2 Effects of Configuration on the Logical Nodes1.2.1 Function parametersDepending on the configuration of the function parameters the functions of the SIPROTEC are enabled or disabled. If a function is disabled, the corresponding Logical Node is not available. The following Logical Nodes are always available:Logical Device Protection: LLN0, LPHD1, XCBR1, PTRC1 Logical Device Measurement: LLN0, LPHD1, MMXU1, MMTR1, MSQI1Logical Device Control: LLN0, LPHD1, CALH1Basics1.2 Effects of Configuration on the Logical Nodes11 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.2.2 Function parameters SIPROTEC 7SJ66The following table shows which Logical Nodes are available when setting the corresponding function parameter.The setting (-) implies that no corresponding LN is available. Table 1-1 SIPROTEC 7SJ 66 - Effects of Function parameters to the Logical Nodes No. Function Setting Logical Nodes103 Setting Group Change Option No effect104 Oscillographic Fault Records Disabled -Enabled RDRE1112 50/51 (Charac. Phase) Overcurrent ProtectionDisabled -Definite Time PTOC6, PTOC7, PTOC1 PTOC18, PTRC2TOC IEC PTOC6, PTOC7, PTOC1PTOC18, PTRC2TOC ANSI PTOC6, PTOC7, PTOC1 PTOC18, PTRC2User Defined PU PTOC6, PTOC7, PTOC1PTOC18, PTRC2Userdef. Reset PTOC6, PTOC7, PTOC1, PTOC18, PTRC2113 50N/51N (Charac. Ground) Overcurrent ProtectionDisabled -Definite Time PTOC8, PTOC9, PTOC2, PTRC2TOC IEC PTOC8, PTOC9, PTOC2, PTRC2TOC ANSI PTOC8, PTOC9, PTOC2, PTRC2User Defined PU PTOC8, PTOC9, PTOC2, PTRC2Userdef. Reset PTOC8, PTOC9, PTOC2, PTRC2Basics 1.2 Effects of Configuration on the Logical Nodes12 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014115 67, 67-TOCDirectional Overcurrent ProtectionDisabled -Definite Time PTOC10, PTOC11, PTOC19,PTOC3,PTRC3TOC IEC PTOC10, PTOC11, PTOC19, PTOC3, PTRC3TOC ANSI PTOC10, PTOC11, PTOC19, PTOC3, PTRC3User Defined PU PTOC10, PTOC11, PTOC19, PTOC3, PTRC3Userdef. Reset PTOC10, PTOC11, PTOC19, PTOC3, PTRC3116 67N, 67N-TOCDirectional Overcurrent Protection Disabled -Definite Time PTOC12, PTOC13, PTOC20, PTOC4, PTRC3TOC IEC PTOC12, PTOC13, PTOC20, PTOC4, PTRC3TOC ANSI PTOC12, PTOC13, PTOC20, PTOC4, PTRC3User Defined PU PTOC12, PTOC13, PTOC20, PTOC4, PTRC3Userdef. Reset PTOC12, PTOC13, PTOC20, PTOC4, PTRC3117 Cold Load Pickup No effect122 2nd Harmonic Inrush Restraint No effectTable 1-1 SIPROTEC 7SJ 66 - Effects of Function parameters to the Logical Nodes (Cont.)No. Function Setting Logical NodesBasics1.2 Effects of Configuration on the Logical Nodes13 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014127 50 1PhSingle Phase Overcurrent ProtectionDisabled -Enabled PTOC16, PTOC17130 (sens.) Ground fault dir. characteristic cos / sin see Parameter 131V0/I0 mea. see Parameter 131131 (sensitive) Ground faultand (sens.) Ground fault dir. characteristic =cos / sin Disabled -Definite Time PHIZ1, PSDE1, PSDE2TOC IEC PHIZ1, PSDE2, PSDE3TOC IANSI PHIZ1, PSDE2, PSDE3User Defined PU PHIZ1, PSDE2, PSDE3Log. inverse 1 PHIZ1, PSDE2, PSDE3Log. inverse 2 PHIZ1, PSDE2, PSDE3131 (sensitive) Ground faultand (sens.) Ground fault dir. characteristic =V0/I0 mea.Disabled -Definite Time PHIZ1, PSDE1, PSDE2User Defined PU PHIZ1, PSDE1, PSDE2133 Intermittent earth fault protection No effect134 Dir. Intermittent earth fault protection No effect140 46 Negative SequenceProtection Disabled -TOC ANSI PTOC14, PTOC15, PTOC5TOC IEC PTOC14, PTOC15, PTOC5Definite Time PTOC14, PTOC15141 48 Startup Supervision of Motors Disabled -Enabled PMSS1Table 1-1 SIPROTEC 7SJ 66 - Effects of Function parameters to the Logical Nodes (Cont.)No. Function Setting Logical NodesBasics 1.2 Effects of Configuration on the Logical Nodes14 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014142 49 Thermal Overload Protection Disabled -No ambient temp PTTR1With amb. temp. PTTR1143 66 Startup Counter for Motors Disabled -Enabled PMRI1144 Load J am Protection Disabled -Enabled PMLJ 1150 27, 59Under/Overvoltage Protection Disabled -Enabled PTUV1, PTUV2, PTOV1, PTOV2154 81 Over/Underfrequency Protection Disabled -Enabled PTOF1 PTOF4,PTUF1 PTUF4155 27/Q-Protection Disabled -Enabled PTUV7161 25 Function group 1Synchronism and Voltage CheckDisabled -SYNCHROCHECK RSYN1170 50BF Breaker Failure Protection Disabled -Enabled RBRF1enabled w/ 3I0> RBRF1171 79 Auto-Reclose Function Disabled -Enabled RREC1172 52 Breaker Wear Monitoring No effect180 Fault Locator Disabled -Enabled RFLO1181 Line sections for fault locator No effectTable 1-1 SIPROTEC 7SJ 66 - Effects of Function parameters to the Logical Nodes (Cont.)No. Function Setting Logical NodesBasics1.2 Effects of Configuration on the Logical Nodes15 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014182 74TC Trip Circuit Supervision Disabled -2 Binary Inputs DOI CirSpv, LN XCBR LD PROT1 Binary Input DOI CirSpv, LN XCBR LD PROT190 External Temperature Input No effect191 Ext. Temperature Input Connection Type No effectTable 1-1 SIPROTEC 7SJ 66 - Effects of Function parameters to the Logical Nodes (Cont.)No. Function Setting Logical NodesBasics 1.3 Allocation of Logical Nodes to Logical Devices16 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.3 Allocation of Logical Nodes to Logical DevicesAll Logical Nodes (LN) are allocated to Logical Devices (LD). The following tables show this allocation and the DOIs available for each LN.LD PROTThe Logical Device PROT (Protection) contains the following LNs:Table 1-2 LD PROT - Logical Nodes LN Function DOILLN0 General Mod, Beh, Health, NamPlt, OpTmhPTRC1 General device pickupGeneral OFFMod, Beh, Health, NamPlt, Str,Tr,FinTrXCBR1 52 BreakerThree-pole trippingMod, Beh, Health, NamPlt, Loc, OpCnt, PosBlkOpn, BlkCls, CBOpCapSumSwARs1, SumSwARs2, SumSwARs3PTOC6PTOC7PTOC18PTOC1PTRC250/51 (Charac. Phase) Mod, Beh, Health, NamPlt, Str, Op, ChgSetPTOC8PTOC9PTOC2PRTC250N/51N (Charac. Ground) Mod, Beh, Health, NamPlt, Str, Op, ChgSetPTOC10PTOC11PTOC19PTOC3PTRC367, 67-TOC Mod, Beh, Health, NamPlt, Str, Op, ChgSetPTOC12PTOC13PTOC20PTOC4PRTC367N, 67N-TOC Mod, Beh, Health, NamPlt, Str, Op, ChgSetPTOC16PTOC1750 1Ph Mod, Beh, Health, NamPlt, Str, OpPTUV1PTUV227 Undervoltage Protection Mod, Beh, Health, NamPlt, Str, OpPTOV1PTOV259Overvoltage Protection Mod, Beh, Health, NamPlt, Str, OpBasics1.3 Allocation of Logical Nodes to Logical Devices17 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTUV7 27/Q-Protection Mod, Beh, Health, NamPlt, Str, OpPTOC14PTOC15PTOC546 Negative SequenceProtection Mod, Beh, Health, NamPlt, Str, OpPMSS1 48 Startup Supervision of Motors Mod, Beh, Health, NamPlt, Str, OpPMRI1 66 Startup Counter for Motors Mod, Beh, Health, NamPlt, Op, StrInhTmmPMLJ 1 Load J am Protection Mod, Beh, Health, NamPlt, Str, Op, LDJ amAlm, ChgSetPTUF1PTUF2PTUF3PTUF481 Underfrequency Protection Mod, Beh, Health, NamPlt, Str, Op, BlkVPTOF1PTOF2PTOF3PTOF481 Overfrequency Protection Mod, Beh, Health, NamPlt, Str, Op, BlkVPTTR1 49 Thermal Overload Protection Mod, Beh, Health, NamPlt, Str, Op, AlmThmPSDE1PSDE2PSDE3(sensitive) Ground fault Mod, Beh, Health, NamPlt, Str, OpPHIZ1 (sensitive) Ground fault Mod, Beh, Health, NamPlt, Str, OpRREC1 79 Auto-Reclose Function Mod, Beh, Health, NamPlt, Op, AutoRecStRFLO1 Fault Locator Mod, Beh, Health, NamPlt, FltZ, FltDiskm, FltDisPrc RBRF1 50BF Breaker Failure Protection Mod, Beh, Health, NamPlt, Str, OpEx, OpInLPHD1 Device PhyNam, PhyHealth, ProxyTable 1-2 LD PROT - Logical Nodes (Cont.)LN Function DOIBasics 1.3 Allocation of Logical Nodes to Logical Devices18 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014LD MEASThe Logical Device MEAS (Measurement) contains the following LNs:LD DRThe Logical Device DR (Disturbance Recorder) contains the following LNs:Table 1-3 LD MEAS - Logical NodesLN Function DOIsLLN0 General Mod, Beh, Health, NamPltMMXU1 Operational measured values Mod, Beh, Health, NamPlt,TotW, TotVAr, TotVA, TotPF, Hz, PPV, PhV, AMMTR1 Power Metering Mod, Beh, Health, NamPlt,SupWh, SupVArh, DmdWh, DmdVArhMSQI1 Measured values, symmetrical components Mod, Beh, Health, NamPlt, SeqA, SeqVLPHD1 Device PhyNam, PhyHealth, ProxyTable 1-4 LD DR - Logical NodesLN Function DOIsLLN0 General Mod, Beh, Health, NamPltRDRE1 Oscillographic Fault Records Mod, Beh, Health, NamPlt, RcdMade, RcdStrFltNum, GriFltNumLPHD1 Device PhyNam, PhyHealth, ProxyBasics1.3 Allocation of Logical Nodes to Logical Devices19 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014LD CTRLThe Logical Device CTRL (Control) contains the following LNs: LD EXTThe Logical Device EXT (Extended) contains the following LNs:The Logical Nodes of the switching (and userdefined) objects will be created by DIGSI during the parameterization of your SIPROTEC device. MICS, Model Implementation Conformance Statement, shows the assignment of the DOIs; you can use DIGSI to print the MICS.Table 1-5 LD CTRL - Logical NodesLN Function DOIsLLN0 General Mod, Beh, Health, NamPlt, LEDRs, LocRSYN1 25 Function group 1 Mod, Beh, Health, NamPlt,Rel, VInd, AngInd, HzInd, SynPrg,DifVClc, DifHzClc, DifAngClcCALH1 Error with a summary alarm and Alarm summary eventMod, Beh, Health, NamPlt, GrAlm, GrWrn,ErrBoard1, ErrBoard2, ErrBoard3, ErrBoard4, ErrBoard5, ErrBoard6, ErrBoard7LPHD1 Device PhyNam, PhyHealth, Proxy, CtlNum, DevStrTable 1-6 LD EXT - Logical NodesLN Function DOIsLLN0 General Mod, Beh, Health, NamPlt, LEDRs, LocLPHD1 Device PhyNam, PhyHealth, Proxy, CtlNumBasics 1.4 Logical Node LLN020 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.4 Logical Node LLN01.4.1 Logical Device PROTLLN0.ModLLN0.BehLLN0.HealthNo. Information51 Device is Operational and Protecting (Device OK) 0 1 1 1 1Test mode (Test mode) x 0 0 1 1Stop data transmission (DataStop) x 0 1 0 1LLN0.Mod.stVal5 1 2 3 4device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1 1 1 1Test mode (Test mode) x 0 0 1 1Stop data transmission (DataStop) x 0 1 0 1LLN0.Beh.stVal5 1 2 3 4device annunciation / setting: 1 - ON / TRUE IEC Status Beh.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1LLN0.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMBasics1.4 Logical Node LLN021 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014LLN0.OpTmhNo. Information Value1020 Counter of operating hours (Op.Hours=)LLN0.OpTmh.stVal Operating hours (Absolute value)Basics 1.4 Logical Node LLN022 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.4.2 Logical Devices MEAS, DR and EXTLLN0.ModLLN0.BehLLN0.HealthNo. Information51 Device is Operational and Protecting (Device OK) 0 1 1 1 1Test mode (Test mode) x 1 1 0 0Stop data transmission (DataStop) x 1 0 1 0LLN0.Mod.stVal5 4 3 2 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1 1 1 1Test mode (Test mode) x 0 0 1 1Stop data transmission (DataStop) x 0 1 0 1LLN0.Beh.stVal5 1 2 3 4device annunciation / setting: 1 - ON / TRUE IEC Status Beh.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1LLN0.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMBasics1.4 Logical Node LLN023 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.4.3 Logical Device CTRLLLN0.ModLLN0.BehLLN0.HealthNo. Information55 Reset Device (Reset Device) 1 1 1 1 151 Device is Operational and Protecting (Device OK) 1 1 1 1 0Test mode (Test mode) 1 1 0 0 0Stop data transmission (DataStop) 1 0 1 0 0LLN0.Mod.stVal4 3 2 1 5device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information55 Reset Device (Reset Device) 1 1 1 1 151 Device is Operational and Protecting (Device OK) 1 1 1 1 0Test mode (Test mode) 1 1 0 0 0Stop data transmission (DataStop) 1 0 1 0 0LLN0.Beh.stVal4 3 2 1 5device annunciation / setting: 1 - ON / TRUE IEC Status Beh.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1LLN0.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMBasics 1.4 Logical Node LLN024 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014LLN0.OpTmhNo. Information Value1020 Counter of operating hours (Op.Hours=)LLN0.OpTmh.stVal Operating hours (Absolute value)Basics1.5 DOI Behavior25 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.5 DOI Behavior1.5.1 Logical Device PROTFor the Logical Nodes of the PROT Logical Device, LNx.Beh.stVal is formed from LNx.Mod.stVal of the Logical Node and the status of the following device messages: Test mode (Test mode), Stop data transmission andAt Least 1 Protection Funct. is Active.No. InformationTest mode (Test mode)x 0 1 0 1 xStop data transmission (DataStop)x 0 0 1 1 x51 Device is Operational and Protecting (Device OK)x 1 1 1 1 0LNx .Mod.stVal5 1 1 1 1 x LNx.Beh.stVal5 1 3 2 4 5device annunciation / setting: 1 - ON / TRUE IEC Status stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFBasics 1.5 DOI Behavior26 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20141.5.2 Logical Devices MEAS, CTRL, DR and EXTFor the Logical Nodes of the MEAS, CTRL, DR and EXT Logical Devices, LNx.Beh.stVal is formed from LNx.Mod.stVal of the Logical Node and the status of the following device messages: Test mode (Test mode), Stop data transmission.No. InformationTest mode (Test mode)x 0 1 0 1 0 1Stop data transmission (DataStop)x 0 0 1 1 x xLNx .Mod.stVal5 1 1 1 1 2 2LNx.Beh.stVal 5 1 3 2 4 2 4device annunciation / setting: 1 - ON / TRUE IEC Status stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFMapping 27 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014Mapping 2ContentsThis chapter shows the mapping of the information relevant to the device on the Logical Node of protocol IEC61850. It is structured according to function. In Chapter 1 you can find what consequences non-configured functions have on the Logical Nodes as well as general information about IEC 61850 mapping of information. 2.1 Device (LPHD1, CALH1) 282.2 Oscillographic Fault Records (RDRE1) 322.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2) 342.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3) 462.5 Single-Phase Overcurrent Protection (PTOC16, PTOC17) 612.6 Voltage Protection 27, 59 (PTUVx, PTOVx) 642.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5) 702.8 Motor Protection (PMSS1, PMRI1) 742.9 Load J am Protection (PMLJ 1) 772.10 Frequency protection 81 O/U (PTUFx, PTOFx) 792.11 QV Protection 27/Q (PTUV9) 952.12 Thermal overload protection (PTTR1) 962.13 Ground Fault Protection 64, 50N(s), 51N(s) (PHIZ1, PSDEx) 982.14 Automatic Reclosing System 79 (RREC1) 1082.15 Fault Locator (RFLO1) 1102.16 Circuit breaker failure protection 50BF(RBRF1) 1122.17 Synchronism and Voltage Check 25 (RSYNx) 1142.18 Three-pole tripping 52 Breaker (XCBR1) 1172.19 Tripping Logic of the Entire Device (PTRC1) 1212.20 Measurement (MMXU1, MSQI1, MMTR1) 123Mapping 2.1 Device (LPHD1, CALH1)28 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.1 Device (LPHD1, CALH1)LPHD1.DevStrLPHD1.ProxyLPHD1.PhyHealthNo. Information56 Initial Start of Device (Initial Start) 0 0 1 167 Resume (Resume) 0 1 0 1LPHD1.DevStr.stVal T 2 1 Tdevice annunciation: 1 - ON IEC Status DevStr.stVal:1 - Initial Start0 - OFF 2 - ResumeT - toggel between 1 and 2No. Information55 Reset Device (Reset Device) 0 1LPHD1.Proxy.stVal 1 0device annunciation: 1 - ON IEC Status Proxy.stVal:0 - DEVICE is not a PROXY0 - OFF 1 - DEVICE is a PROXYNo. Information51 Device is Operational and Protecting (Device OK) 0 1LPHD1.PhyHealth.stVal 3 1device annunciation: 1 - ON IEC Status PhyHealth.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.1 Device (LPHD1, CALH1)29 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.1.1 Error with a summary alarm and Alarm summary eventCALH1.ModCALH1.HealthCALH1.GrAlmCALH1.GrWrnNo. Information56 Initial Start of Device (Initial Start) 1 0CALH1.Mod.stVal1 5device annunciation: 1 - ON IEC Status Mod.stVal:1 - ON0 - OFF 2 - BLOCKED3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1CALH1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information140 Error with a summary alarm (Error Sum Alarm) 1 0CALH1.GrAlm.stVal1 0device annunciation: 1 - ON IEC Status GrAlm.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information160 Alarm Summary Event (Alarm Sum Event) 1 0CALH1.GrWrn.stVal 1 0device annunciation: 1 - ON IEC Status GrWrn.stVal:0 - FALSE0 - OFF 1 - TRUEMapping 2.1 Device (LPHD1, CALH1)30 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014The LN CALH1.ErrBoard1 to CALH1.ErrBoard7 are available with Firmware CALH1.ErrBoard1CALH1.ErrBoard2CALH1.ErrBoard3CALH1.ErrBoard4No. Information183 Error Board 1 (Error Board 1) 1 0CALH1.ErrBoard1.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard1.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information184 Error Board 2 (Error Board 2) 1 0CALH1.ErrBoard2.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard2.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information185 Error Board 3 (Error Board 3) 1 0CALH1.ErrBoard3.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard3.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information186 Error Board 4 (Error Board 4) 1 0CALH1.ErrBoard4.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard4.stVal:0 - FALSE0 - OFF 1 - TRUEMapping2.1 Device (LPHD1, CALH1)31 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014CALH1.ErrBoard5CALH1.ErrBoard6CALH1.ErrBoard7No. Information187 Error Board 5 (Error Board 5) 1 0CALH1.ErrBoard5.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard5.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information188 Error Board 6 (Error Board 6) 1 0CALH1.ErrBoard6.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard6.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information189 Error Board 7 (Error Board 7) 1 0CALH1.ErrBoard7.stVal 1 0device annunciation: 1 - ON IEC Status ErrBoard7.stVal:0 - FALSE0 - OFF 1 - TRUEMapping 2.2 Oscillographic Fault Records (RDRE1)32 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.2 Oscillographic Fault Records (RDRE1)RDRE1.ModRDRE1.HealthRDRE1.RcdMadeNo. Information55 Reset Device (Reset Device) xRDRE1.Mod.stVal1device annunciation: 1 - ON IEC Status Mod.stVal:1 - ON0 - OFF 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1RDRE1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information30053 Fault recording is running (Fault rec. run.) 0 1RDRE1.RcdMade.stVal 1 0device annunciation: 1 - ON IEC Status RcdMade.stVal:0 - FALSE0 - OFF 1 - TRUE (Recording complete)Mapping2.2 Oscillographic Fault Records (RDRE1)33 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014RDRE1.FltNumRDRE1.GriFltNumRDRE1.RcdStrNo. Information Value302 Fault Event (Fault Event) RDRE1.FltNum.stVal Present fault numberNo. Information Value301 Power System fault (Pow.Sys.Flt.) RDRE1.GriFltNum.stVal Network fault numberNo. Information30053 Fault recording is running (Fault rec. run.) 0 1RDRE1.RcdStr.stVal 0 1device annunciation: 1 - ON IEC Status RcdStr.stVal:0 - FALSE0 - OFF 1 - TRUEMapping 2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)34 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)2.3.1 Overcurrent Protection 50, 51 PH (PTOC6, PTOC7, PTOC18, PTOC1)PTOC6.ModPTOC6.HealthPTOC6.StrPTOC6.OpNo. Information1751 50/51 O/C switched OFF (50/51 PH OFF) 1 x 050-1 PICKUP (P1204) = x 1 0PTOC6.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC6.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information1810 50-1 picked up (50-1 picked up) 0 1PTOC6.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information1815 50-1 TRIP (50-1 TRIP) 0 1PTOC6.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)35 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC6.ChgSetPTOC7.ModPTOC7.HealthPTOC7.StrNo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC6.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information1751 50/51 O/C switched OFF (50/51 PH OFF) 1 x 050-2 PICKUP (P1202) = x 1 0PTOC7.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC7.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information1800 50-2 picked up (50-2 picked up) 0 1PTOC7.Str.general0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)36 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC7.OpPTOC7.ChgSetPTOC18.ModPTOC18.HealthNo. Information1805 50-2 TRIP (50-2 TRIP) 0 1PTOC7.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC7.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information1751 50/51 O/C switched OFF (50/51 PH OFF) 1 x 050-3 PICKUP(P1217) = x 1 0PTOC18.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC18.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)37 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC18.StrPTOC18.OpPTOC18.ChgSetPTOC1.ModNo. Information1767 50-3 picked up (50-3 picked up) 0 1PTOC18.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information1769 50-3 TRIP (50-3 TRIP) 0 1PTOC18.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC18.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information1751 50/51 O/C switched OFF (50/51 PH OFF) 1 0PTOC1.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFMapping 2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)38 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC1.HealthPTOC1.StrPTOC1.OpPTOC1.ChgSetNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information1820 51 picked up (51 picked up) 0 1PTOC1.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information1825 51 TRIP (51 TRIP) 0 1PTOC1.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC1.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUEMapping2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)39 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.3.2 Overcurrent Protection 50N, 51N (PTOC8, PTOC9, PTOC2)PTOC8.ModPTOC8.HealthPTOC8.StrPTOC8.OpNo. Information7156 50N/51N is OFF (50N/51N OFF) 1 x 050N-1 PICKUP (P1304) = x 1 0PTOC8.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC8.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information1834 50N-1 picked up (50N-1 picked up) 0 1PTOC8.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information1836 50N-1 TRIP (50N-1 TRIP) 0 1PTOC8.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)40 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC8.ChgSetPTOC9.ModPTOC9.HealthPTOC9.StrNo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC8.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information7156 50N/51N is OFF (50N/51N OFF) 1 x 050N-2 PICKUP (P1302) = x 1 0PTOC9.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC9.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information1831 50N-2 picked up (50N-2 picked up) 0 1PTOC9.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEMapping2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)41 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC9.OpPTOC9.ChgSetPTOC2.ModPTOC2.HealthNo. Information1833 50N-2 TRIP (50N-2 TRIP) 0 1PTOC9.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC9.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information1756 50N/51N is OFF (50N/51N OFF) 1 0PTOC2.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC2.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping 2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)42 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC2.StrPTOC2.OpPTOC2.ChgSetNo. Information1837 51N picked up (51N picked up) 0 1PTOC2.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information1839 51N TRIP (51N TRIP) 0 1PTOC2.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC2.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUEMapping2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)43 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.3.3 Overcurrent Protection 50N, 51N (PTRC2)PTRC2.ModPTRC2.HealthPTRC2.StrPTRC2.Str.dirGeneralNo. Information1751175650/51 O/C switched OFF (50/51 PH OFF) and 50N/51N is OFF (50N/51N OFF)1 0PTRC2.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTRC2.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information1761 50(N)/51(N)O/C PICKUP (50(N)/51(N) PU) 0 1PTRC2.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. InformationPTRC2.Str.dirGeneral0device annunciation: IEC Status Str.dirGeneral:0 - UNKNOWNMapping 2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)44 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTRC2.Str.phsAPTRC2.Str.dirPhsAPTRC2.Str.phsBPTRC2.Str.dirPhsBPTRC2.Str.phsCNo. Information1762 50/51PhaseA picked up (50/51 Ph A PU) 0 1PTRC2.Str.phsA0 1device annunciation: 1 - ON IEC Status Str.phsA:0 - FALSE0 - OFF 1 - TRUENo. InformationPTRC2.Str.dirPhsA 0device annunciation: IEC Status Str.dirPhsA:0 - UNKNOWNNo. Information1763 50/51PhaseB picked up (50/51 Ph B PU) 0 1PTRC2.Str.phsB0 1device annunciation: 1 - ON IEC Status Str.phsB:0 - FALSE0 - OFF 1 - TRUENo. InformationPTRC2.Str.dirPhsB0device annunciation: IEC Status Str.dirPhsB:0 - UNKNOWNNo. Information1764 50/51PhaseC picked up (50/51 Ph C PU) 0 1PTRC2.Str.phsC 0 1device annunciation: 1 - ON IEC Status Str.phsC:0 - FALSE0 - OFF 1 - TRUEMapping2.3 Overcurrent Protection 50, 51, 50N, 51N (PTOCx, PTRC2)45 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTRC2.Str.dirPhsCPTRC2.Str.neutPTRC2.Str.dirNeutPTRC2.OpNo. InformationPTRC2.Str.dirPhsC0device annunciation: IEC Status Str.dirPhsC:0 - UNKNOWNNo. Information1765 50N/51N picked up (50N/51NPickedup) 0 1PTRC2.Str.neut 0 1device annunciation: 1 - ON IEC Status Str.neut:0 - FALSE0 - OFF 1 - TRUENo. InformationPTRC2.Str.dirNeut0device annunciation: IEC Status Str.dirPhsC:0 - UNKNOWNNo. Information1791 50(N)/51(N)TRIP (50(N)/51(N)TRIP) 0 1PTRC2.Op.general0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)46 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)2.4.1 Directional Overcurrent Protection 67 (PTOC10, PTOC11, PTOC19, PTOC3)PTOC10.ModPTOC10.HealthPTOC10.StrNo. Information2651 67/67-TOC switched OFF (67/67-TOCOFF) 1 x 067-1 PICKUP (P1504) = x 1 0PTOC10.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC10.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2660 67-1 picked up (67-1 picked up) 0 1PTOC10.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)47 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC10.OpPTOC10.ChgSetPTOC11.ModPTOC11.HealthNo. Information2665 67-1 TRIP (67-1 TRIP) 0 1PTOC10.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC10.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information2651 67/67-TOC switched OFF (67/67-TOCOFF) 1 x 067-2 PICKUP (P1502) = x 1 0PTOC11.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC11.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)48 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC11.StrPTOC11.OpPTOC11.ChgSetPTOC19.ModNo. Information2642 67-2 picked up (67-2 picked up) 0 1PTOC11.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information2649 67-2 TRIP (67-2 TRIP) 0 1PTOC11.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC11.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information2651 67/67-TOC switched OFF (67/67-TOCOFF) 1 x 067-3 PICKUP (P1528) = x 1 0PTOC19.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)49 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC19.HealthPTOC19.StrPTOC19.OpPTOC19.ChgSetNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC19.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2697 67-3 picked up (67-3 picked up) 0 1PTOC19.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information2678 67-3 TRIP (67-3 TRIP) 0 1PTOC19.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC19.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUEMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)50 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC3.ModPTOC3.HealthPTOC3.StrPTOC3.OpNo. Information2651 67/67-TOC switched OFF (67/67-TOCOFF) 1 0PTOC3.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC3.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2670 67-TOC picked up (67-TOC picked up) 0 1PTOC3.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information2675 67-TOC TRIP (67-TOC TRIP) 0 1PTOC3.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)51 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC3.ChgSetNo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC3.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUEMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)52 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.4.2 Directional Overcurrent Protection 67N (PTOC12, PTOC13, PTOC20, PTOC4)PTOC12.ModPTOC12.HealthPTOC12.StrPTOC12.OpNo. Information2656 67N/67N-TOCswitched OFF (67N OFF) 1 x 067N-1 PICKUP (P1604) = x 1 0PTOC12.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC12.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2681 67N-1 picked up (67N-1 picked up) 0 1PTOC12.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information2683 67N-1 TRIP (67N-1 TRIP) 0 1PTOC12.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)53 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC12.ChgSetPTOC13.ModPTOC13.HealthPTOC13.StrNo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC12.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information2656 67N/67N-TOCswitched OFF (67N OFF) 1 x 067N-2 PICKUP (P1602) = x 1 0PTOC13.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC13.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2646 67N-2 picked up (67N-2 picked up) 0 1PTOC13.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)54 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC13.OpPTOC13.ChgSetPTOC20.ModPTOC20.HealthNo. Information2679 67N-2 TRIP (67N-2 TRIP) 0 1PTOC13.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC13.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information2656 67N/67N-TOCswitched OFF (67N OFF) 1 x 067N-3 PICKUP (P1628) = x 1 0PTOC20.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC20.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)55 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC20.StrPTOC20.OpPTOC20.ChgSetPTOC4.ModNo. Information2698 67N-3 picked up (67N-3 picked up) 0 1PTOC20.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information2603 67N-3 TRIP (67N-3 TRIP) 0 1PTOC20.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC20.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUENo. Information2656 67N/67N-TOCswitched OFF (67N OFF) 1 x 0M.of PU TD (P1630) = x 1 0PTOC4.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)56 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC4.HealthPTOC4.StrPTOC4.OpPTOC4.ChgSetNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC4.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2684 67N-TOCpicked up (67N-TOCPickedup) 0 1PTOC4.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information2686 67N-TOCTRIP (67N-TOC TRIP) 0 1PTOC4.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information1997 Dynamic settings are ACTIVE (Dyn set. ACTIVE) 0 1PTOC4.ChgSet.stVal 0 1device annunciation: 1 - ON IEC Status ChgSet.stVal:0 - FALSE0 - OFF 1 - TRUEMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)57 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.4.3 Directional Overcurrent Protection 67N (PTRC3)PTRC3.Mod PTRC3.HealthPTRC3.StrNo. Information67/67-TOC switched OFF (67/67-TOCOFF) (I 2651) and 67N/67N-TOCswitched OFF (67N OFF) (I 2656) 1 0PTRC3.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTRC3.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information2691 67/67N picked up (67/67N pickedup) 0 1PTRC3.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)58 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTRC3.Str.dirGeneralPTRC3.Str.phsAPTRC3.Str.dirPhsANo. Information2691 67/67N picked up (67/67N picked up) 0 1 1 1 1Phase A forward (Phase A forward) (I 2628) orPhase B forward (Phase B forward) (I 2629) orPhase C forward (Phase C forward) (I 2630) orGround forward (Ground forward) (I 2635)x 0 1 0 1Phase A reverse (Phase A reverse) (I 2632) orPhase B reverse (Phase B reverse) (I 2633) orPhase C reverse (Phase C reverse) (I 2634) orGround reverse (Ground reverse) (I 2636)x 0 0 1 1PTRC3.Str.dirGeneral0 0 1 2 3device annunciation: 1 - ON IEC Status Str.dirGeneral:0 - UNKNOWN0 - OFF 1 - FORWARD2 - BACKWARD3 - BOTHNo. Information2692 67/67-TOC Phase A picked up (67 A picked up) 0 1PTRC3.Str.phsA0 1device annunciation: 1 - ON IEC Status Str.phsA:0 - FALSE0 - OFF 1 - TRUENo. Information2692 67/67-TOC Phase A picked up (67 A picked up) 0 1 1 1 12628 Phase A forward (Phase A forward) x 0 1 0 12632 Phase A reverse (Phase A reverse) x 0 0 1 1PTRC3.Str.dirPhsA 0 0 1 2 3device annunciation: 1 - ON IEC Status Str.dirPhsA:0 - UNKNOWN0 - OFF 1 - FORWARDx - irrelevant 2 - BACKWARDMapping2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)59 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTRC3.Str.phsBPTRC3.Str.dirPhsBPTRC3.Str.phsCPTRC3.Str.dirPhsCNo. Information2693 67/67-TOC Phase B picked up (67 B picked up) 0 1PTRC3.Str.phsB0 1device annunciation: 1 - ON IEC Status Str.phsB:0 - FALSE0 - OFF 1 - TRUENo. Information2693 67/67-TOC Phase B picked up (67 B picked up) 0 1 1 1 12629 Phase B forward (Phase B forward) x 0 1 0 12633 Phase B reverse (Phase B reverse) x 0 0 1 1PTRC3.Str.dirPhsB0 0 1 2 3device annunciation: 1 - ON IEC Status Str.dirPhsB:0 - UNKNOWN0 - OFF 1 - FORWARDx - irrelevant 2 - BACKWARDNo. Information2694 67/67-TOC Phase C picked up (67 C picked up) 0 1PTRC3.Str.phsC 0 1device annunciation: 1 - ON IEC Status Str.phsC:0 - FALSE0 - OFF 1 - TRUENo. Information2694 67/67-TOC Phase C picked up (67 C picked up) 0 1 1 1 12630 Phase C forward (Phase C forward) x 0 1 0 12634 Phase C reverse (Phase C reverse) x 0 0 1 1PTRC3.Str.dirPhsC0 0 1 2 3device annunciation: 1 - ON IEC Status Str.dirPhsC:0 - UNKNOWN0 - OFF 1 - FORWARDx - irrelevant 2 - BACKWARDMapping 2.4 Directional Overcurrent Protection 67, 67N (PTOCx, PTRC3)60 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTRC3.Str.neutPTRC3.Str.dirNeutPTRC3.OpNo. Information2695 67N/67N-TOC picked up (67N picked up) 0 1PTRC3.Str.neut 0 1device annunciation: 1 - ON IEC Status Str.neut:0 - FALSE0 - OFF 1 - TRUENo. Information2695 67N/67N-TOC picked up (67N picked up) 0 1 1 1 12635 Ground forward (Ground forward) x 0 1 0 12636 Ground reverse (Ground reverse) x 0 0 1 1PTRC3.Str.dirNeut 0 0 1 2 3device annunciation: 1 - ON IEC Status Str.dirPhsC:0 - UNKNOWN0 - OFF 1 - FORWARDx - irrelevant 2 - BACKWARDNo. Information2696 67/67N TRIP (67/67N TRIP) 0 1PTRC3.Op.general0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping2.5 Single-Phase Overcurrent Protection (PTOC16, PTOC17)61 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.5 Single-Phase Overcurrent Protection (PTOC16, PTOC17)PTOC16.ModPTOC16.HealthPTOC16.StrPTOC16.OpNo. Information5961 50 1Ph is OFF (50 1Ph OFF) 1 x 050 1Ph-1 PICKUP (P2705) = x 1 0PTOC16.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC16.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information5974 50 1Ph-1 picked up (50 1Ph-1 PU) 0 1PTOC16.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information5975 50 1Ph-1 TRIP (50 1Ph-1 TRIP) 0 1PTOC16.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.5 Single-Phase Overcurrent Protection (PTOC16, PTOC17)62 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC17.ModPTOC17.HealthNo. Information5961 50 1Ph is OFF (50 1Ph OFF) 1 x 050 1Ph-2 PICKUP (P2703) = x 1 0PTOC17.Mod.stVal5 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC17.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.5 Single-Phase Overcurrent Protection (PTOC16, PTOC17)63 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC17.StrPTOC17.OpNo. Information5977 50 1Ph-2 picked up (50 1Ph-2 PU) 0 1PTOC17.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information5979 50 1Ph-2 TRIP (50 1Ph-2 TRIP) 0 1PTOC17.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.6 Voltage Protection 27, 59 (PTUVx, PTOVx)64 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.6 Voltage Protection 27, 59 (PTUVx, PTOVx)2.6.1 Undervoltage Protection 27 (PTUV1)PTUV1.ModPTUV1.HealthNo. Information6530 27 Undervoltage protection switched OFF (27 OFF) 1 0PTUV1.Mod.stVal 5 1device annunciation: 1 - ON IEC Status Mod.stVal:1 - ON0 - OFF 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTUV1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.6 Voltage Protection 27, 59 (PTUVx, PTOVx)65 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTUV1.StrPTUV1.OpNo. Information6533 27-1 Undervoltagepicked up (27-1 picked up) 0 x 16534 27-1 UndervoltagePICKUP w/curr. superv (27-1 PU CS) 0 1 xPTUV1.Str.general 0 1 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEx - irrelevantNo. Information6539 27-1 UndervoltageTRIP (27-1 TRIP) 0 1 PTUV1.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.6 Voltage Protection 27, 59 (PTUVx, PTOVx)66 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.6.2 Undervoltage Protection 27 (PTUV2) PTUV2.ModPTUV2.HealthNo. Information6530 27 Undervoltage protection switched OFF (27 OFF) 1 0PTUV2.Mod.stVal 5 1device annunciation: 1 - ON IEC Status Mod.stVal:1 - ON0 - OFF 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTUV2.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.6 Voltage Protection 27, 59 (PTUVx, PTOVx)67 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTUV2.StrPTUV2.OpNo. Information6537 27-2 Undervoltagepicked up (27-2 picked up) 0 x 16538 27-2 Undervoltage PICKUPw/curr. superv (27-2 PU CS) 0 1 xPTUV2.Str.general0 1 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUEX - irrelevantNo. Information6540 27-2 UndervoltageTRIP (27-2 TRIP) 0 1 PTUV2.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.6 Voltage Protection 27, 59 (PTUVx, PTOVx)68 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.6.3 Overvoltage Protection 59 (PTOV1) PTOV1.ModPTOV1.HealthPTOV1.StrPTOV1.OpNo. Information6565 59-Overvoltage protection switched OFF (59 OFF) 1 0PTOV1.Mod.stVal 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOV1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information6568 59picked up (59-1 picked up) 0 1PTOV1.Str.general0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information6570 59 TRIP (59-1 TRIP) 0 1PTOV1.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping2.6 Voltage Protection 27, 59 (PTUVx, PTOVx)69 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.6.4 Overvoltage Protection 59 (PTOV2)PTOV2.ModPTOV2.HealthPTOV2.StrPTOV2.OpNo. Information6565 59-Overvoltage protection switched OFF (59 OFF) 1 0PTOV2.Mod.stVal 5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOV2.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information6571 59-2 Overvoltage V>>picked up (59-2 picked up) 0 1PTOV2.Str.general0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information6573 59-2 Overvoltage V>>TRIP (59-2 TRIP) 0 1 PTOV2.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5)70 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5)PTOC14.ModPTOC14.HealthPTOC14.StrPTOC14.OpNo. Information5151 46switched OFF (46 OFF) 1 0PTOC14.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC14.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information5165 46-1 picked up (46-1 picked up) 0 1PTOC14.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information46-1TRIP (46-1 TRIP) 0 1PTOC14.Op.general 0 1device annunciation / setting: 1 - ON / TRUE IEC Status Op.general:0 - FALSE0 - OFF / FALSE 1 - TRUEMapping2.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5)71 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC15.ModPTOC15.HealthPTOC15.StrPTOC15.OpNo. Information5151 46switched OFF (46 OFF) 1 0PTOC15.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC15.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information5159 46-2 picked up (46-2 picked up) 0 1PTOC15.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information46-2TRIP (46-2 TRIP) 0 1PTOC15.Op.general 0 1device annunciation / setting: 1 - ON / TRUE IEC Status Op.general:0 - FALSE0 - OFF / FALSE 1 - TRUEMapping 2.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5)72 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC5.ModPTOC5.HealthNo. Information5151 46switched OFF (46 OFF) 1 0PTOC5.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PTOC5.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.7 Negative Sequence Protection 46 (PTOC14, PTOC15, PTOC5)73 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PTOC5.StrPTOC5.OpNo. Information5166 46-TOC picked up (46-TOC pickedup) 0 1PTOC5.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information46-TOCTRIP (46-TOC TRIP) 0 1PTOC5.Op.general 0 1device annunciation / setting: 1 - ON / TRUE IEC Status Op.general:0 - FALSE0 - OFF / FALSE 1 - TRUEMapping 2.8 Motor Protection (PMSS1, PMRI1)74 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.8 Motor Protection (PMSS1, PMRI1)2.8.1 Motor Starting Protection 48 (PMSS1) PMSS1.ModPMSS1.HealthNo. Information6811 Startup supervision OFF (START-SUP OFF) 1 0PMSS1.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PMSS1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping2.8 Motor Protection (PMSS1, PMRI1)75 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PMSS1.StrPMSS1.OpNo. Information6823 Startup supervision Pickup (START-SUP pu) 0 1PMSS1.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information6821 Startup supervision TRIP (START-SUP TRIP) 0 1PMSS1.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping 2.8 Motor Protection (PMSS1, PMRI1)76 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.8.2 Motor Restart Inhibit 66 (PMRI1)PMRI1.ModPMRI1.HealthPMRI1.OpPMRI1.StrInhTmmNo. Information4824 66 Motor start protection OFF (66 OFF)) 1 0PMRI1.Mod.stVal5 1device annunciation: 1 - ON IEC Status Mod.stVal:1 - ON0 - OFF 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PMRI1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMNo. Information4827 66 Motor start protection TRIP (66 TRIP) 0 1PMRI1.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information Value809 Time untill release of reclose-blocking (T reclose=) PMRI1.StrInhTmm.stVal Absolute valueMapping2.9 Load J am Protection (PMLJ 1)77 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.9 Load Jam Protection (PMLJ1) Function available with Firmware PMLJ1.ModPMLJ1.HealthNo. Information10022 Load J am Protection is OFF (J AM PROT.OFF) 1 0PMLJ1.Mod.stVal5 1device annunciation / setting: 1 - ON / TRUE IEC Status Mod.stVal:1 - ON0 - OFF / FALSE 2 - BLOCKEDx - irrelevant 3 - TEST4 - TEST/BLOCKED5 - OFFNo. Information51 Device is Operational and Protecting (Device OK) 0 1PMLJ1.Health.stVal 3 1device annunciation: 1 - ON IEC Status Health.stVal:1 - OK0 - OFF 2 - WARNING3 - ALARMMapping 2.9 Load J am Protection (PMLJ 1)78 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.2014PMLJ1.StrPMLJ1.OpPMLJ1.LodJamAlmNo. Information10025 Load J am Protection picked up (Load J am pickup) 0 1PMLJ1.Str.general 0 1device annunciation: 1 - ON IEC Status Str.general:0 - FALSE0 - OFF 1 - TRUENo. Information10026 Load J am Protection TRIP (Load J am TRIP) 0 1PMLJ1.Op.general 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUENo. Information10024 Load J am Protection alarm (Load J am alarm) 0 1PMLJ1.LodJamAlm.stVal 0 1device annunciation: 1 - ON IEC Status Op.general:0 - FALSE0 - OFF 1 - TRUEMapping2.10 Frequency protection 81 O/U (PTUFx, PTOFx)79 SIPROTEC, 7SJ 66, IEC61850 MAPPINGC53000-L2640-C554-1, Edition 03.20142.10 Frequency protection 81 O/U(PTUFx, PTOFx)2.10.1 Frequency protection 81-1 U (PTUF1)PTUF1.ModPTUF1.HealthNo. Information5211 81 OFF (81 OFF) x 1 081-1 PICKUP (P5403/5404)