60pn6500 spring training pdp.pptx
DESCRIPTION
plasma trainingLGTRANSCRIPT
Welcome to LG Electronics 2013 PDP TV Service Training
HE Division
National Trainer / HE
Presented by Nebil Yaylagul
Welcome To
Antistatic Wrist Strap
Antistatic device is used to safely ground a person working on very sensitive electronicequipment. It prevents the buildup of static electricity on your body, which can result In electrostatic discharge ( ESD )
Technicians must wear an Antistatic Wrist Strap during servicing any LG product !!!!
http://www.newegg.ca/Product/Product.aspx?Item=N82E16899261005
PDP 60PN6500 SERVICE TRAINING
PN6500 SERIES
84” 60” 50” 46” 42” 37” 32”
YSUS
YDRV
CTRL
MAIN
Power Supply ZSUS
X Boards
60PN6500 Circuit Boards
60PN6500 Power supply VS Adj.
VA Tp.
VA Adj.
VS Tp.
Logic signals needed to
generate drive waveformGenerates Vsc, -Vy and V Set Up
from Vs by transformer
Control Board
IPM’s generate Sustain Waveform
Distributes 5v VA VS Distributes 5v
Distributes 5v VA
Receive 5V,Va, Vsfrom SMPS
Transfer Waveformto Y Drive Board
Z SUS Board
Top and Bottom Center and Left X Boards
Power Supply Board - SMPS
FETs amplify Sustain Wave-form
Generates Vsc, -Vy and V Set Upfrom Vs by transformer
Drive circuit generates Sustain Waveform
Transfer Waveformvia Y Drive Board to the panel
FETs amplify Sustain Wave-form
60PN6500 YSUS BOARD
Vset-UP
Vset-DN
VSC TEST P.
YSUS_DN / RECOVERYYSUS_UP DRIVE AMP.
VSC Adj
60PN6500 YSUS BOARD
V_SETUP & V_SETDN
Timing syncControlled by software and modulated by the CTRL board pulses.
V_SET UP
-VY
V_SET DN
YSUS Scan DATA
VSC Timing
YSUS WAVEFORM
X Board Right Top and Bottom
Distribute 5v, VA
Drivers generates erase,sustain waveforms
Generates Z Bias
Distributes 5v, VA, VS
FET Makes Drive waveform
Via FPC (flexible printed circuit )
Control Board Receive 5v, VA, VS
PSU Board
60PN6500 ZSUS Board
60PN6500 ZSUS Board
Tech must enter the white washMode before any adjustments.
ZSUS board supply the sustainpulse to the panel.
DC voltage Is adjusted by PDP specs and with GND. Reference.
VZBIASDC-115V.
ZSUS DATA
VZB Tp.
VZB Adj.
60PN6500 Main Board
2 Ch. Audio amp
LVDS
Video CPU
Keyboard/ IR
VS_DA Located on the Control Board just above the AUTO Gen Test Points may be used as an external trigger source for locking the waveform on the Oscilloscope
External Triggering of the Oscilloscope allows for a Stable Display of both the Y and Z SUS Output Waveforms regardless of how distorted the waveforms may be, allowing the wave shape and phasing to be easily examined.
60PN6500 Control Board
Auto Gen Tp.
5V. 3.3V.
R-G-B Data
CTRL Pulse
Making 전자 6-2
Revision
PDP TV SymptomA. Picture Problem
Mal discharge Symptom
Repair Process-Reference data
▣ Dot type Mal-discharge
A14
2011. 2 . 28
▣ Dark picture caused by Mal-discharge ▣ Scan type Mal-discharge symptom
MAL-DISCHARGE
Control scan related symptoms can be caused by YDRV circuit boards.Shorted drive chips prevents or interrupts the panel’s pixel mapping order.
MAL-DISCHARGE DUE TO SHORTED SCAN DATA
USB Download manual for User
1/10
TV Software Upgrade
Current Ver.
Ver. 01.02
Update Ver.
Ver. 01.03
IMFOMATION
CANCEL
FILE : Merge-42PX3D-UE-RELEASE-0x0103.bin
START
1. USB Download manual for User
2/10
To start upgrading your TV Set, please follow the procedures:
1. Press an arrow key on your remote to reach START on the screen.2. Press ENTER key on your remote to start downloading.
If you do not want to download the upgrade file, please press the arrow key to reach CANCEL on the screen.Then, press the ENTER key on your remote.
1. Power On2. Insert usb-stick to usb port in monitor. If download file is over than current version,
Main picture will be diplayed below (If download file is not exsited in usb stick or under than current version, nothing will be displayed)
< Copying the file from the Memory >
TV Software Upgrade
Copy the file from the Memory…
Do not remove the memory card from the port ! Do not plug off !
1. USB Download manual for User
3. Download starting through pressing the enter key in remocon
3/10
TV Software Upgrade
UPGRADING...
10 % Do not plug off !
<Upgrade Progressing Picture>
4. Automatical updating after file downloadingAt this time, it is possible for removing usb stick. But power must be supported in TV Set.
1. USB Download manual for User
4/10
TV Software Upgrade
UPGRADING...
< Upgrade Ending Picture >
COMPLETED
1. USB Download manual for User
5/10
5. If “COMPLETED” message is displayed in picture after completing up-grade, Downloading is over.TV Set is automatically reseted.
Thank you / Mercihttp://www.lg.com
20% 30% 40% 50% 60% 70% 80% 90% 100%
20%30%40%50%60%70%80%90%100%
60PN6500
PDP TV Skill Quiz
A- In start System 1
B- In start System 2
C- No Serial no# to be entered for this model
D- Adjust option menu
Q1- After replacement of a main board, where can we input model & serial number into TV set?
PDP TV Skill Quiz
A- Smart Phone
B- USB 2
C- Windows 7 desktop computer.
D- AC-3 / PCM .
Q2- What Audio format is compatible with LG TV.
PDP TV Skill Quiz
Q3- If there is no raster on TV, where should we check first?
A- Replace the main board
B- Replace the Power supply board
C- Replace YSUS board
D- Perform the AutoGen test procedure for panel’s diagnostics.
PDP TV Skill Quiz
Q4- What can cause a dark and faded image on plasma panel?
A- Defective YSUS
B- Faulty power supply board.
C- Defective Control board
D- Defective ZSUS
PDP TV Skill Quiz
60PN6500
PDP TV Skill QuizThe Answers !!
A- In start System 1
B- In start System 2
C- No Serial no# to be entered for this model
D- Adjust option menu
Q1- After replacement of a main board, where can we input model & serial number into TV set?
A- Smart Phone
B- USB2 input
C- Windows 7 desktop computer.
D- AC-3 / PCM
Q2- What audio format is compatible with LG TV?
Q3- If there is no raster on TV, where should we check first?
A- Replace the main board
B- Replace the Power supply board
C- Replace YSUS board
D- Perform the AutoGen test procedure for panel’s diagnostics.
Q4- What can cause a dark and faded image on plasma panel?
A- Defective YSUS
B- Faulty power supply board.
C- Defective Control board
D- Defective ZSUS