Page 1: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector
Page 2: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

2

60/100 Concentric Flue System Parts

MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector 3. Wall bracket

MG83815 Vertical Terminal 60/100 (Avanta 12/18/24v) 1. Vertical terminal 2. Wall bracket

MG82329 Std Concentric Flue 60/100 (Avanta 12/18/24v) 1. Boiler bend (Avanta 12/18/24v) 2. Telescopic terminal 3. Wall plates - (2 x white)

MG82328(MG82335 1m extended option)Std Concentric Flue 60/100 (Avanta Plus) 1. Low profile bend (Avanta Plus) 2. Telescopic terminal 3. Wall plates - (2 x white)

1

2 3

1

2

3

1

3 2

1

2

Page 3: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

3

MG87910 Roof flashing (20° to 45° pitched)

MG87372 Roof flashing (flat)

MG83236 - 250mm MG83237 - 500mm MG83238 - 1000mm Flue Extension Piece (cannot be cut) c/w Clamp

MG83241 - 500mm MG83242 - 1000mm Flue Extension Piece (cuttable) c/w Clamp

MG83240 - 275 to 315mm Flue extension piece (adjustable) c/w Clamp

MG83247 90° Bend c/w Clamp (single seal)

MG83248 45° Bend c/w Clamp (single seal)

Page 4: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

4

60/100mm Concentric Flue Spare Parts(not all illustrated)

Part No Description 116534 LP adaptor plate (Avanta Plus) MG27218 Air inlet seal for LP boiler bend (flue side) MG87650 Clamp MG87720 Wall bracket 100mm MG27245 Air inlet seal for Avanta 18v boiler bend MG85010 Wall plate - Black MG75682 Wall Plate - White

Wall Plate See table for part Nos.

MG83243

S62768 Boiler connector (Avanta Plus) - for vertical outlet supplied as standard with Part No. MG82330 Vertical flue kit (Avanta Plus) -

MG82333 LP Bend + adaptor plate (Avanta Plus)

116534 LP adaptor plate (Avanta Plus) -supplied as standard with boiler-

Page 5: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

5

Avanta Plus 60/100mm Concentric Flue System

MG82330 - Vertical Flue (Avanta Plus) Installed in Flat Roof

99 o/d

805 ±10 to inside weathercollar

615 ±10 to rooflevel

10120 o/d Min Hole in roof

To suit site

MG82330 - Vertical Flue (Avanta Plus) Installed in Pitched Roof

45

5

Weather collar detail

805±10To inside of weather collar

760±10

Pitch20° to 45°

1099 o/d

120 o/d Min Hole in Roof

To suit site

MG82328 Std Concentric Flue 60/100 ( Avanta Plus) installed 1. Low profile bend (Avanta Plus) 2. Telescopic terminal 3. Wall plates (2 white)

Wall Depth Max 450mm - Min 250mm

Terminal is telescopic132.5

Core Drill Wall - 125mm Dia.C/L of Terminal

98

Top of boiler

100

NOTE: If the wall depth is less than 250mm the telescopic terminal can still be used by removing the boiler end part and cutting the remaining outer part down to suit wall depth (min 150mm) + 60mm out of wall to connect to bend) Remember to leave the inner pipe 10mm longer than the outer

Page 6: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

6

Avanta 12/18/24ov 60/100mm Concentric Flue System

MG83815 - Vertical Flue (Avanta 12/18/24ov) Installed on Flat Roof

99 o/d

805 ±10 to inside weathercollar

615 ±10 to rooflevel

10

120 o/d Min Hole in roof

45

5

Weather collar detail

MG83815 - Vertical Flue (Avanta 12/18/24ov) Installed in Pitched Roof

805±10To inside of weather collar

760±10

Pitch20° to 45°

1099 o/d

120 o/d Min Hole in Roof

Wall Depth Max 450mm - Min 250mm

Terminal is telescopic132.5

Core Drill Wall - 125mm Dia.

Top of boiler

164

C/L of Terminal

NOTE: If the wall depth is less than 250mm the telescopic terminal can still be used by removing the boiler end part and cutting the remaining outer part down to suit wall depth (min 150mm) + 60mm out of wall to connect to bend) Remember to leave the inner pipe 10mm longer than the outer

MG82329 Std Concentric Flue 60/100 ( Avanta ov) installed 1. Boiler bend (Avanta ov) 2. Telescopic terminal 3. Wall plates (2 white)

Page 7: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

7

Avanta Plus 60/100mm Plume Management Kits

MG82331 PMK-Horizontal Terminal Kit (Avanta Plus) 1. PMK Wall terminal 2. LP boiler bend (Avanta Plus) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60mm) 5. Support bracket (60mm) 6. 90 bend (60mm) 7. Flue outlet (60mm) 8. Bird guard NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards

PMK– Horizontal Terminal Kit installed

Wall Depth - Max 550mm - Min 150mm

Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference

Core Drill Wall - 125mm Dia.

Max

110

0mm

- M

in 1

50m

m

Not

e: C

an b

e ex

tend

ed w

ith e

xtra

par

ts

C/L of Terminal

98

Top of boiler

100

132.5

1

2

3

4 5

6 7 8

Page 8: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

8

Avanta Plus 60/100mm Plume Management Kits

PMK– Horizontal Terminal Kit with a vertical outlet installed

Wall Depth - Max 550mm - Min 150mm

Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference

Core Drill Wall - 125mm Dia.

Sta

ndar

d Te

rmin

al

Max

100

0mm

- M

in 1

50m

m

Not

e: C

an b

e ex

tend

ed w

ith e

xtra

par

ts

Roof level

132.5

C/L of Terminal

98

Top of boiler

100

MG82331 + MG83235 PMK-Horizontal Terminal Kit (Avanta Plus) 1. PMK Wall terminal 2. LP boiler bend (Avanta Plus) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60) 5. Support bracket (60) 6. Vertical outlet NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards The vertical outlet replaces the 90 bend, flue outlet and bird guard which are dis-carded.

1

2

3

4

5

6

Page 9: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

9

Avanta 12/18/24ov 60/100mm Plume Management Kits

PMK Horizontal Terminal Kit (Avanta 12/18/24ov) installed

Wall Depth - Max 550mm - Min 150mm

Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference100

132.5

Top of boilerflue outlet

164

C/L of TerminalCore Drill Wall - 125mm Dia.

Max

110

0mm

- M

in 1

50m

m

Not

e: C

an b

e ex

tend

ed w

ith e

xtra

par

ts

MG83230 PMK-Horizontal Terminal Kit (Avanta ov) 1. PMK Wall terminal 2. Boiler bend (Avanta ov) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60mm) 5. Support bracket (60mm) 6. 90 bend (60mm) 7. Flue outlet (60mm) 8. Bird guard NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards

1

2

3

4

5

6 7 8

Page 10: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

10

Avanta 12/18/24ov 60/100mm Plume Management Kits

PMK Horizontal Terminal (Avanta 12/18/24ov) with a vertical outlet installed

Wall Depth - Max 550mm - Min 150mm

Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference100

132.5

Top of boilerflue outlet

164

C/L of TerminalCore Drill Wall - 125mm Dia.

Roof level

MG83230 + MG83235 PMK-Horizontal Terminal Kit (Avanta OV) 1. PMK Wall terminal 2. LP boiler bend (Avanta OV) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60mm) 5. Support bracket (60mm) 6. Vertical outlet NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards The vertical outlet replaces the 90 bend, flue outlet and bird guard which is dis-carded.

1

2

3

4

5

6

Sta

ndar

d T

erm

inal

M

ax 1

000m

m -

Min

150

mm

N

ote:

Can

be

exte

nded

with

ext

ra p

arts

Page 11: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

11

Avanta Plus 60/100mm PMK Balcony Terminal Kit

MG82332 PMK Balcony Flue 60/100mm(Avanta Plus) 1. PMK Balcony terminal 2. LP Boiler bend (Avanta Plus) 3. Wall plates (1 white and 1 black) 4. Two 1000mm flue extensions (60mm) 5. Two Support brackets(60mm) 6. Flue outlet (60mm) 7. Bird guard NOTE: Horizontal Terminal unit must be installed with the flue exit point at the top of the air inlet. (flue exit is offset from centre line)

PMK Balcony Flue 60/100 (Avanta Plus) installed for a 2M overhang

Wall Depth - Max 550mm - Min 150mm Terminal can be cut to suit

Core Drill Wall - 125mm Dia. Balcony

Standard Balcony Kit for up to 2M One additional length allowed up to a Max of 3M

Note: the extension kit must be graded back to the Terminal at approx 3° to allow condensate to drain to boiler

C/L of Terminal

98

Top of boiler

100

132.5

1

2

3 4 5 6

7

Wall Depth - Max 550mm -Min 150mm Terminal can be cut to suit

Page 12: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

12

Avanta 12/18/24ov 60/100mm PMK Balcony Terminal Kit

MG82322 PMK Balcony Flue 60/100mm (Avanta ov) 1. PMK Balcony terminal 2. Boiler bend (Avanta ov) 3. Wall plates (1 white and 1 black) 4. Two 1000mm flue extensions (60mm) 5. Two Support brackets(60mm) 6. Flue outlet (60mm) 7. Bird guard NOTE: Horizontal Terminal unit must be installed with the flue exit point at the top of the air inlet. (flue exit is offset from centre line)

PMK– Balcony Flue 60/100mm (Avanta ov) installed for a 2M overhang

164

Top of boiler

C/L of Terminal

100

132.5

Note: the extension kit must be graded back to the Terminal at approx 3° to allow condensate to drain to boiler

Standard Balcony Kit for up to 2M overhang One additional length allowed up to a Max of 3M

Balcony

Wall Depth - Max 700mm - Min 150mm Terminal can be cut to suit

Core Drill Wall - 125mm Dia.

1

2

3 4 5

6

7

Page 13: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector

13

MG82323 PMK-Horizontal outlet (60)

MG83235 PMK-Vertical outlet terminal (60)

MG83234 PMK– 1000mm Flue Exten-sion piece c/w wall bracket (60)

MG83231 PMK-45°Angle deflector (60) for use with Std Wall Terminal Kits (MG82328 and MG82329) only

MG83232 PMK-90° Bend (60)

MG83233 PMK-45° Bend (60)

60/100 Plume Management Spare Parts

MG82325 PMK-Wall bracket (60) not illustrated

60/100 Plume Management Spare Parts

MG82320 PMK-Horizontal Terminal only

MG83249 PMK-90° Bend + horizontal outlet c/w bird guard (60)

MG82321 PMK-Balcony Terminal only

Steve Jepson
Typewritten Text
Page 14: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector
Page 15: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector
Page 16: 60/100 Concentric Flue System Parts - MKM Building … · 60/100 Concentric Flue System Parts MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector