  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    1/26

    Proprietary and Confidential

    Installation

    FibeAir IP-10 G-Series

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    2/26

    Proprietary and Confidential

    General

    2

    If installation requires CFG file upload & download and / or SW fileupload & down -

    1. Make sure FTP Server is installed on your PC2. FTP is configured (RD/WR permissions)

    3. Latest SW version is available (FTP root directory)

    FTP installation guide

    is available at

    Training.Ceragon.Com:

    see Modules /

    Installation

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    3/26

    Proprietary and Confidential

    Site Requirements

    3

    IDU must be located indoors

    The environment temperature must be between -5 C and +45 C.

    Easily accessible, but only by authorized personnel.

    Available power source of -48 VDC, and the site must comply with

    National Electric Code (NEC) standards.

    Available management connection (Ethernet or dial-up). IDU-ODU connection (IF cable): no more than 300m

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    4/26

    Proprietary and Confidential

    Site Requirements

    4

    Heat Dissipation:

    The IP-10 IDU overall heat dissipation is 25W max (~85 BTU/h).The ODU heat dissipation is 100W max.

    Antenna Location:

    As with any type of construction, a local permit may be required before installingan antenna. It is the owners responsibility to obtain any and all permits.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    5/26

    Proprietary and Confidential

    IDU Dimensions

    5

    42.60mm

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    6/26

    Proprietary and Confidential

    Installing standalone IDU in a 19 Rack

    6

    As shown in the illustration, four screws, supplied with theinstallation kit, are used to secure the IDU to the rack.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    7/26Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    7

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    8/26Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    8

    Before you install theenclosures

    Plan carefully the requiredspace within the rack !

    Should you need to install 3enclosures prepare at least10Us (6Us for enclosures + 2Us freespace for maneuvering above and below

    shelves)

    Start the installation processfrom bottom to top, e.g. Mainenclosure should be installedfirst at the bottom of your rackspace

    Main Enclosure

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    9/26Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    9

    Step #1:Install the IP-10 Main enclosurein the 19 inch rack using 4screws.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    10/26Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    10

    Step #1:Install the IP-10 Main enclosurein the 19 inch rack using 4screws.

    Step #2:

    Slide down the 2nd extensionenclosure. Male connectorshould plug in smoothly into theMain enclosure.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    11/26Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    11

    Step #1:Install the IP-10 Main enclosurein the 19 inch rack using 4screws.

    Step #2:

    Slide down the 2nd extensionenclosure. Male connectorshould plug in smoothly into theMain enclosure.

    Step #3:

    Slide down the 2nd extensionenclosure. Male connectorshould be plugged in smoothlyinto the Main enclosure.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    12/26Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    12

    Step #4:Secure the 2nd extension intothe Main enclosure. Use thebuilt-in screw.

    Mount the 2nd extension into the

    rack using the 4 screws

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    13/26

    Proprietary and Confidential

    Installing Nodal Enclosures in a 19 Rack

    13

    Step #4:Secure the 2nd extensioninto the Main enclosure.Use the built-in screw.

    Mount the 2nd extension

    into the rack using the 4screws

    Step #5:Add the 3rd extensionwhen needed

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    14/26

    Proprietary and Confidential

    Preparing the IDU for a Shelf installation

    14

    Remove the two 19" brackets mounted on the IP-10 IDU by unscrewing the 3

    screws at each side.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    15/26

    Proprietary and Confidential

    Installing the IDU in a Shelf

    15

    Slide the IP-10 IDU into the enclosure and tighten it using 2 screws. Repeat

    this step in accordance with the configuration.

    IDU insertion & extractionshould NOT be under power

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    16/26

    Proprietary and Confidential

    Installing a Blank Panel IDU in a Shelf

    16

    Slide the IP-10 blank panel into the enclosure, and tighten it using 2 screws.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    17/26

    Proprietary and Confidential

    Installing a T-Card into an IDU

    17

    Remove the IP-10 T-Card blank panel from the IDU, by releasing the 2 side

    screws.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    18/26

    Proprietary and Confidential

    Installing a T-Card into an IDU

    18

    Insert the IP-10 T-Card panel and tighten it using the 2 side screws.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    19/26

    Proprietary and Confidential

    Grounding the IDU

    19

    Single Point Stud

    Grounding Wire

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    20/26

    Proprietary and Confidential

    Grounding the IDU

    20

    The IDU is suitable for installation in a Common Bonding Network (CBN).

    Only copper wire should be used.

    The wire must be at least 14 AWG.

    Connector and connection surfaces must be plated. Bare conductors must be

    coated with antioxidant before crimp connections are made to the screws.

    FibeAir provides a ground for each IDU, via a one-hole mounted lug onto asingle-point stud.

    The stud must be installed using a UL-listed ring tongue terminal, and two star

    washers for anti-rotation.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    21/26

    Proprietary and Confidential

    Power General Requirements

    21

    1. A readily accessible Listed branch circuit over-current protective device,rated 15 A, must be incorporated in the building wiring.

    2. This equipment is designed to permit connection between the earthedconductor of the DC supply circuit and the earthing conductor at theequipment.

    3. The equipment shall be connected to a properly grounded supply system

    4. The DC supply system is to be local, i.e. within the same premises as theequipment

    5. A disconnect device is not allowed in the grounded circuit between the DCsupply source and the frame/grounded circuit connection.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    22/26

    Proprietary and Confidential

    Power Requirements

    22

    When selecting a power source, the following must be considered:

    DC power can be from -40.5 VDC to -60 VDC.

    Recommended: Availability of a UPS (Uninterrupted Power Source),

    battery backup, and emergency power generator.

    Whether or not the power source provides constant power (i.e., power issecured on weekends or is shut off frequently and consistently).

    The power supply must have grounding points on the AC and DC sides.

    The user power supply GND must be connected to the positive pole in the IDU

    power supply.

    Any other connection may cause damage to the system!

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    23/26

    Proprietary and Confidential

    Power Requirements

    23

    Important

    Make sure to use a circuit breaker to protect the circuit from damage byshort or overload.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    24/26

    Proprietary and Confidential

    Installing the IDU-ODU IF cable

    24

    Route the IF Coax Cable from the IDU to the ODU/RFU and terminate it

    with N-type male connectors.

    Note: Make sure you fasten the cable along the ladder!

    Make sure that the inner pin of the connector does not exceed theedge of the connector.

    The cable should have a maximum attenuation of 30 dB at 350 MHz.

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    25/26

    Proprietary and Confidential

    Logging in, assigning IP address

    CLI access groups:

    Viewer read-onlyaccess

    Operator read-writeaccess but cannot add/remove other users

    Admin read-writeaccess including add/remove other users

    Tech read-writeaccess including add/remove other users as

    well as access to a bridge-specific CLI shell

    Currently only Admin is defined

    Other groups or users can be created via CLI only

  • 7/31/2019 4 -IP-10G Install - Presentation v1.0

    26/26

    P i t d C fid ti l

    Thank You !