36 safety related sketches5
TRANSCRIPT
Locations of fence post or railing indicatively
Entry
Entry
Entry
Entry
Ladder locationnot more than 8000mm
When railingfixed, provide warning tape in day
warning coloured lights at night
Trench by m ass excavation
Section
8000
3000
Ladders
Railing in case it is ins ide big project or fencing when plot boundary
Trench v ertical s ides cons idered in good soil. No slope shown
5000
0
50000
Typical Section applicable indicatively to all sidesExcavation safety of a major building project with ordinary foundations
Ramp Ingress/Egress
For heavy vehicles/equipment
Ramp location to be decided on site
width 4000/6000 depending on requirement
If required dewatering to be doneWell points to be installed around & trench base
Headers & Miller pumps on ground
Bank/Flag Man to signal
Trench by m ass excavation
Section
9000
Typical Section applicable indicatively to all sidesExcavation safety of a major building project with benching
Manhole
benchings
Foundation working area to be dry
Dewatering system not shown on plan
Safety rails on lowe benches not shown
Generally applicable in sandy strata
Typical shown only for railing
Ground Level
Excavation Level
Sump
Submersible pump
Dewatering hose pipe to manhole
Dewatering hose pipe to manhole can be @ 2 locations
Submersible pump in sump
Submersible pump in sump
Excavations safety
Sketch 5