24.12.2004 1
Comparison Comparison oof Kinematic Results f Kinematic Results
Between METU-KISS Between METU-KISS & & Ankara Ankara
University-VICON Gait Analysis University-VICON Gait Analysis
SystemsSystems
EZGİ CİVEKEZGİ CİVEK
supervised by: Asst. Prof. Dr. Ergin Tönüksupervised by: Asst. Prof. Dr. Ergin Tönük
Prof. Dr. Turgut TümerProf. Dr. Turgut Tümer
24.12.2004 2
OutlineOutline
IntroductionIntroduction Gait AnalysisGait Analysis Motion Capture SystemsMotion Capture Systems Comparison of the two systemsComparison of the two systems Comparison of the kinematic resultsComparison of the kinematic results Future StudiesFuture Studies
24.12.2004 3
ObjectiveObjective
To comparecompare the kinematic results of two different gait analysis systems.
ExchangingExchanging the motion data between KISS & VICON.
Studying the same subject on each system.
Data AcquisitionAcquisition Data Analysis
PerformancePerformance Methodology
24.12.2004 4
ObjectiveObjective
To makemake KISS compatible with a common widely used file format.
To enlarge the database available.
24.12.2004 5
Gait AnalysisGait Analysis
Analysis of the mechanics of human Analysis of the mechanics of human body during walking, stair body during walking, stair ascending/descending, obstacle ascending/descending, obstacle avoidance.avoidance.
24.12.2004 6
Gait AnalysisGait Analysis
Gait analysis plays a key role in:Gait analysis plays a key role in:
Diagnosis of disorders in lower extremityDiagnosis of disorders in lower extremity
Decision making before operationsDecision making before operations
Evaluation of prosthetic joint replacementsEvaluation of prosthetic joint replacements
Comparison of gait parameters before and Comparison of gait parameters before and after operationsafter operations
Studies in orthotics, amputees, athletic Studies in orthotics, amputees, athletic injuriesinjuries
24.12.2004 7
Human GaitHuman Gait
24.12.2004 8
Motion Capture SystemsMotion Capture Systems
HARDWAREHARDWARE
CCD CamerasCCD Cameras MarkersMarkers Force Plate(s)Force Plate(s) EMG UnitEMG Unit
SOFTWARESOFTWARE
Data Data AcquisitionAcquisition
Calculation of Calculation of Gait Gait ParametersParameters
24.12.2004 9
Marker LocationsMarker Locations
24.12.2004 10
KISSKISS VICONVICON
Locally developed in Locally developed in MEME
6 cameras6 cameras
2 force plates2 force plates
KISS – DAQKISS – DAQ
KISS – GAITKISS – GAIT
Helen Hayes Marker Helen Hayes Marker setset
Commercial systemCommercial system
5 cameras5 cameras
2 force plates2 force plates
VICON 370VICON 370
Vicon Clinical Vicon Clinical ManagerManager
Helen Hayes Marker Helen Hayes Marker setset
24.12.2004 11
File FormatsFile Formats
KISSKISS
*.hvd*.hvd
*.yor*.yor
VICONVICON
*.tvd*.tvd
*.c3d*.c3d
Raw video dataRaw video data(input for 3D (input for 3D reconstruction)reconstruction)
Processed data fileProcessed data file
(3D trajectory data) (3D trajectory data)
input for kinematic input for kinematic data analysisdata analysis
24.12.2004 12
C3D - A 3D Biomechanics Data C3D - A 3D Biomechanics Data StandardStandard
Developed by Andrew Dainis in 1987.
Used by almost all commercial motion capture systems.
24.12.2004 13
Converting *.yor file to *.c3d
Export the coordinate data from *.yor file as *.txt format.
Arrange the data in text file according to c3d format.
Create *.c3d file by a program called ‘C3D Editor’.
24.12.2004 14
KISSKISS VICON VICON
24.12.2004 15
KISSKISSVICOVICONN
24.12.2004 16
Future StudiesFuture Studies
Converting *.c3d to *.yor file format.
Studying the same subject in both systems.
Writing a program for the arrangenments of files required in the conversion process.