2019 international sales meeting
TRANSCRIPT
![Page 1: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/1.jpg)
![Page 2: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/2.jpg)
2019 International Sales Meeting
Process Burner Division
Eric Pratchard – General Manager
![Page 3: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/3.jpg)
Process Burners
Agenda
Organizational Chart
Burner Technology Advancements
▪ Free Jet G2
▪ Zenith
Existing Product Line
▪ Single Jet
▪ Radiant Wall
Test Facility
![Page 4: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/4.jpg)
Organizational Chart
Global Representation
![Page 5: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/5.jpg)
Process Burner Organization – Global
![Page 6: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/6.jpg)
Burner Technology Advancements
GLSF FREE-JET G2
Zeeco Zenith
![Page 7: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/7.jpg)
GLSF FREE-JET G2
The Second Generation
![Page 8: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/8.jpg)
GLSF FREE-JET G2
Customer Feedback
▪ Our fuel supply does have liquid carry over. Can you design tips with larger orifices?
▪ What happens if the primary tips plug?
▪ What percentage of primary tips can plug before we have to shut down?
▪ Why do you need so many secondary tips?
▪ Why can’t all secondary tips have the same drill size and angle?
![Page 9: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/9.jpg)
Generation 1 Design
Fuel Gas Manifold
(Guides Gas Through
Burner)
Burner Tile (Air Orifice)
Controls Air Flow
Burner Tips (Gas Orifice)
Controls Gas Flow
Damper Blades (Controls Excess Air)
ExMo Auxiliary Riser
Windbox (Guide Air Through Burner)
Muffler Noise
(Reduction)
Pilot
![Page 10: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/10.jpg)
How It Works
Products of Combustion
(Heat is Produced)
Fuel Gas
Combustion Air
Inert
Flue Gas
Fuel Gas
Auxiliary Gas
![Page 11: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/11.jpg)
Minimal Change – Major Impact
![Page 12: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/12.jpg)
Mechanical Impact
SizePrimary Tip Qty Secondary Tip Qty
Gen 1 Gen 2 Gen 1 Gen 2
6 2 2 22 11
8 2 3 26 13
9 2 3 28 14
10 2 3 30 15
12 2 4 34 17
13 2 4 38 16
14 2 4 42 21
15 3 4 46 23
16 3 5 48 24
18 4 5 54 27
Primary Orifice Φ
▪ Gen 1: .0625”
▪ Gen 2: .0937”
Secondary Orifice Φ
▪ Gen 1: .0937”
▪ Gen 2: 0.144”
![Page 13: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/13.jpg)
Proven Test Results
Fuel Component Test Pt.
1
Test
Pt. 2
Test
Pt. 3
Test
Pt. 4
Test
Pt. 5
Test
Pt. 6
Nat Gas, Vol % 100 100 50 50 40 40
H2, Vol % 25 25 40 40
Propane, Vol % 25 25 20 20
Secondary Tip
Design
Primary Tip
Design
Primary Tip
Count
NOx,
ppm
NOx,
ppm
NOx,
ppm
NOx,
ppm
NOx,
ppm
NOx,
ppm
Gen 1 Gen 1 2 10.4 10.9 12.0 12.7 12.2 12.8
Gen 1 Gen 2 2 10.4 10.0 11.6 10.2 12.3 12.3
Gen 2 Gen 2 2 8.8 8.0 11.9 13.8 13.4 13.9
Gen 2 Gen 2 3 9.8 9.8 14.0 15.9 16.5 16.5
Gen 2 Gen 2 4 13.4 15.6 16.7 17.0 18.6 20.0
![Page 14: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/14.jpg)
GLSF FREE-JET G2
100% Nat Gas – Design Heat Release
![Page 15: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/15.jpg)
GLSF FREE-JET G2
100% Nat Gas – 2:1 Turndown
![Page 16: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/16.jpg)
GLSF FREE-JET G2
50% NG / 25% C3 / 25% H2 – Design Heat Release
![Page 17: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/17.jpg)
Selling Points
New Heater Installations▪ Increased Primary Tip Count Improves Stability, Reliability & Safety ▪ Reduced Secondary Tip Quantity Lowers Maintenance Cost▪ Increased Tip Diameter Reduces Maintenance Interval▪ 3/32” Minimum Primary Firing Diameter
Retrofit Opportunities▪ Two Options
• Replace Existing Quantity of Primary Tips and Risers• Provide New Front Plate with Increased Primary Tip Count
▪ Replacement Secondary Tips and Risers▪ Plugs for Manifold Locations No Longer in Use▪ Revalidate Original Process Warranty for 12 Months
![Page 18: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/18.jpg)
Zeeco Zenith
Cold Furnace Emissions Compliance
![Page 19: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/19.jpg)
Customer Challenge
Satisfy emissions through the heater’s full operational range. CO and NOx
Allowances
▪ Forced draft system with no pressure limitation
▪ Contribute to instrument & control design
▪ Contribute to control narrative and operational philosophy
![Page 20: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/20.jpg)
Development Process
Zeeco Zenith
Combination Lean Pre-Mix / Free Jet
NOx ≤ 10 ppmvd @ 3% O2
CO ≤ 100 ppmvd @ 3% O2
GLSF Free Jet
NOx ≤ 10 ppmvd @ 3% O2
CO > 100 ppmvd @ 3% O2 below 1000°F
Lean Pre-Mix Burner
NOx > 10 ppmvd @ 3% O2 above 1000°F
CO < 100 ppmvd @ 3% O2
![Page 21: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/21.jpg)
3D Representation
![Page 22: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/22.jpg)
Flame Length
Side ViewIsometric View
![Page 23: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/23.jpg)
Velocity Magnitude & Vectors – Side View
Lean Pre-Mix
Stage
![Page 24: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/24.jpg)
Velocity Magnitude & Vectors – Side View
FREE-JET
Stage
![Page 25: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/25.jpg)
Lean Pre-mix Stage
![Page 26: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/26.jpg)
FREE-JET Stage
![Page 27: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/27.jpg)
Proven Test Results
Point 1 Point 2 Point 3 Point 4 Point 5
Natural Gas 100 100 100 100 100
LPM Heat Release (MMbtu/hr) 1.5 3.0 5.0 5.0 3.0
FJ Heat Release (MMbtu/hr) - - - 3.0 5.0
Furnace Temperature (°F) 887 1120 1278 1606 1626
Floor Temperature (°F) 600 795 932 1168 1192
Oxygen % 8.1 8.5 9.6 3.1 1.9
CO (ppmv) 63.7 4.4 17.5 0.0 0.0
NOx (ppmv) 6.4 4.9 5.5 6.7 8.4
CO (ppmv @ 3% O2) 89 6.4 27.6 0.0 0.0
NOx (ppmv @ 3% O2) 10 7.6 8.7 6.7 7.9
![Page 28: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/28.jpg)
Proven Test Results
0
2
4
6
8
10
12
1.5 3 4 5 6.5 8 10
NO
x @
3%
O2
MMbtu/hr
NOx vs. Heat Release
LPM FJ Stage
![Page 29: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/29.jpg)
Existing Product Line
![Page 30: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/30.jpg)
GB Single Jet
![Page 31: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/31.jpg)
GB Single Jet
Zeeco has taken a conventional single tip with a cone design
burner and enhanced the concept using the same, tip, cone
and tile, to achieve Low NOx emissions.
![Page 32: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/32.jpg)
Overall Design Concept
Burner Tile (Air Orifice)
Controls Air Flow
Burner Tips (Gas Orifice)
Controls Gas Flow
Pilot
Damper Blades (Controls Excess Air)
Muffler Noise
(Reduction)
Windbox (Guide Air Through Burner)
Tile Case and
Mounting Plate
![Page 33: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/33.jpg)
How It Works
Inert
Flue Gas
Combustion Air
Fuel Gas
Firing Ports
IFGR Zone
Combustion Air Zone
Staged Air Zone
![Page 34: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/34.jpg)
Design Summary
Round flame or Flat flame gas burner
design
NOx reduction method: Internal Flue Gas
Recirculation (IFGR), staged fuel, and
staged air. Combustion air induction:
natural, forced, induced and balanced
draft, or turbine exhaust
Mounting options: up-fired, side-fired and
down-fired
![Page 35: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/35.jpg)
Performance Summary
Ultra Low NOx Emissions:▪ NOx (Gas Fired) Range (Natural Draft): 20 to 49
ppmv
Heat Release Range:▪ Nat. Draft: 1 to 20 MM Btu/hr▪ F.D.: 1 to 20 MM Btu/hr Turndown: 10:1 or
greater for most cases
Design Excess Air Range:10% to 25% for most cases
Combustion Air Pressure Drop:▪ Natural Draft: 0.2” to 1” (5 to 25 mm) H2O▪ Forced Draft: 0.5” to 2” (12.7 to 51 mm) H2O
![Page 36: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/36.jpg)
Radiant Walls
![Page 37: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/37.jpg)
Radiant Wall
![Page 38: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/38.jpg)
How It Works
![Page 39: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/39.jpg)
![Page 40: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/40.jpg)
Design Summary
Radiant wall, gas only burner design
NOx reduction method: lean pre-mixing of the gas and air.
Combustion air induction: natural draft or forced draft
Mounting options: horizontally-mounted
310 stainless steel cast gas tip
304 stainless steel venturi mixer
60% alumina tile assembly pre-fired
![Page 41: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/41.jpg)
Performance Summary
Ultra-Low NOx Emissions:▪ NOx Range (Natural Draft): 40 to 70 ppmv
Heat Release Range:▪ Nat. Draft: 0.25 to 1.4 MM Btu/hr
Turndown: 3:1 or greater for most cases
Design Excess Air Range: 10% for most cases
![Page 42: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/42.jpg)
Test Facility
![Page 43: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/43.jpg)
Test Facility Capabilities
17 test furnaces
Capable of firing:
▪ Down-fired
• Dual Burner Potential
▪ Up-fired
• Multi Burner Potential
▪ Horizontal-fired
▪ Multiple burners
• Dual Hearth Burners with Radiant Walls
Draft Options
▪ Natural
▪ Forced
▪ Balanced
![Page 44: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/44.jpg)
Test Facility Capabilities
Standard Fuel Components
▪ Natural Gas
▪ Hydrogen
▪ Propane
▪ #6 Oil
▪ Nitrogen
Customer Fuel Components
▪ Carbon Dioxide
▪ Butane
▪ Diesel
Firing Capacity
▪ 60 MM btu/hr continuous operation on Natural Gas
▪ Furnace capability up to 100 MM btu/hr
▪ Boiler capability up to 200 MM btu/hr
Pre-Heat Maximum: 500°F
![Page 45: 2019 International Sales Meeting](https://reader031.vdocuments.site/reader031/viewer/2022012221/61e034905b02d24e0c50561a/html5/thumbnails/45.jpg)
Test Facility Flyover