20181015 thinbrik applications flyer - acme brick · 2018-11-01 · thick set thin set modular...

2
3024 Acme Brick Plaza, Fort Worth TX 76109 brick.com • (800) 792-1234 APPLICATIONS THICK SET MORTAR SYSTEM THIN SET MORTAR SYSTEM THICK SET MORTAR SYSTEM MODULAR PANEL SYSTEM PRE-CAST WALL SYSTEM THICK SET MORTAR BED SYSTEM thinBRIK thinBRIK thinBRIK thinBRIK Metal Lath Metal Lath Metal Lath thinBRIK thinBRIK & Adhesive These are recommendations only for typical applications. Always follow the requirements of your local codes and manufacturers recommendations. For more information visit www.gobrick.com/docs/default-source/read- research-documents/technicalnotes/28c-thin-brick-veneer.pdf Bonding Coat Bonding Coat Bonding Coat Bonding Coat Scratch Coat Scratch Coat Scratch Coat Scratch Coat Pre-Cast Concrete Air & Vapor Barrier Metal Wall Panel Drainage Mat Support Wall Exterior Insulation Pre-Cast or Poured Concrete Exterior Sheathing Concrete Block Air & Vapor Barrier Air & Vapor Barrier Metal or Wood Stud Exterior Sheathing Drainage Mat Metal or Wood Stud Over Exterior Insulation Over Concrete Wall Over Stud Wall Over Stud Wall Over CMU Wall

Upload: others

Post on 17-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 20181015 ThinBRIK Applications Flyer - Acme Brick · 2018-11-01 · Thick SeT Thin SeT Modular PanelS Pre-caST PanelS wn aries in thickness thinBRIK - Extruded flexible applications

3024 Acme Brick Plaza, Fort Worth TX 76109brick.com • (800) 792-1234

APPLICATIONSThick SeT MorTar SYSTeM

Thin SeT MorTar SYSTeM

Thick SeT MorTar SYSTeM

Modular Panel SYSTeM

Pre-caST Wall SYSTeM

Thick SeT MorTar Bed SYSTeM

thinBRIK

thinBRIK

thinBRIK thinBRIKMetal Lath

Metal Lath

Metal Lath

thinBRIK

thinBRIK & Adhesive

These are recommendations only for typical applications. Always follow the requirements of your local codes and manufacturers recommendations. For more information visit www.gobrick.com/docs/default-source/read-research-documents/technicalnotes/28c-thin-brick-veneer.pdf

BondingCoat

BondingCoat

BondingCoat

BondingCoat

Scratch Coat

Scratch Coat

Scratch Coat

Scratch Coat

Pre-Cast Concrete

Air & Vapor Barrier

Metal Wall Panel

Drainage Mat

Support Wall

Exterior Insulation

Pre-Cast orPoured Concrete

Exterior Sheathing

Concrete Block

Air & Vapor Barrier

Air & Vapor Barrier

Metal or Wood Stud

ExteriorSheathing

Drainage MatMetal or Wood Stud

Over Exterior Insulation

Over Concrete Wall

Over Stud Wall

Over Stud Wall

Over CMU Wall

Page 2: 20181015 ThinBRIK Applications Flyer - Acme Brick · 2018-11-01 · Thick SeT Thin SeT Modular PanelS Pre-caST PanelS wn aries in thickness thinBRIK - Extruded flexible applications

Thick SeT

Thin SeT

Modular PanelS

Pre-caST PanelS

thinB

RIK -

Extru

ded

typi

cally

for c

omm

ercia

l use,

flex

ible a

pplic

ation

s

thinB

RIK -

Kerfed

Ext

rude

d

com

mer

cial u

se on

ly, em

bedd

ed in

pre

cast

conc

rete

TC Tile

typi

cally

for c

omm

ercia

l use,

flex

ible a

pplic

ation

s

thinB

RIK -

Sawn

for c

omm

ercia

l & re

siden

tial u

se, va

ries i

n thi

ckne

ss

3024 Acme Brick Plaza, Fort Worth TX 76109brick.com • (800) 792-1234

These are recommendations only for typical applications. Always follow the requirements of your local codes and manufacturers recommendations. For more information visit www.gobrick.com/docs/default-source/read-research-documents/technicalnotes/28c-thin-brick-veneer.pdf

thinBRIKSawn

thinBRIKExtruded

thinBRIKKerfed Extruded

TC Tile

Mortar: Type N or Latex-Modified

Mortar: Latex-Modified

Mortar: Type N or Latex-Modified

Panels & Adhesive: Per Panel Manufacturer

Instructions

Verify Brick System Requirements

Form Liner: Architectural Polymers,

Innovative Brick Systems LLC,

Advanced Formliners LLC

inSTallaTion MeThod

recoMMended

MaTerialS

SPecial

conSideraTionS

Follow mortar manufacturer’s instructions for

thickness of bond coat and other brick setting

requirements.

Follow mortar manufacturer’s instructions for

thickness of bond coat and other brick setting

requirements.

Check thin brick thickness tolerances for

panel system. In the absence of guidelines,

maximum tolderance of ±1/16th inch is recommended.

PCI complance may be required. In some

cases, PCI dimensional tolerances have been

waived when products meet all other testing

requirements.