2010 electrical and data presentation

12
Ahrend Ltd. - 27 november 2009 1 1 USA Electrical & Data Solutions UL Approved US cabling solutions for Ahrend

Upload: inarvaez

Post on 13-Jul-2015

629 views

Category:

Documents


0 download

TRANSCRIPT

Ahrend Ltd. - 27 november 2009 11

USA Electr ical & Data Solut ionsUL Approved US cabling solutions for Ahrend

Ahrend Ltd. - 27 november 2009 2

A5 0 0 Desking Cable Managem ent Solut ions

A500 Cable ClampsPlastic colour 27 soft black, allow wires to be run along the beam. Guiding and securing surplus Data wires and user wires for a clean wiring solution.

These clamps are also used to install the S2 Metal and Plastic Panels that are used for modesty and privacy in the A500 Desking solution.

Ahrend Ltd. - 27 november 2009 3

A5 0 0 Desking Cable Managem ent Solut ions

A500 Cable TraysMetal Trays, allow wires to be hidden & secured in the housing that opens to allow the user to access and maintain the desks wiring needs. Chargers, phones and computer cables are managed neatly.

We do not run power in these trays as they are not to UL code. This is a neater solution for wire management

Ahrend Ltd. - 27 november 2009 44

Leg Covers

Infeed entry through cover at base of leg

Infeed exits through cover at top of leg

For many types of legs – Metal leg covers cleanly br inging pow er from the floor to the shared cable tray or A500 beam.

Ahrend Ltd. - 27 november 2009 55

Electr ical Solut ion – 2 Circuit – Beam clipped Solut ion

Elect r ical System for A5 0 0 Desking and Benching solutions

4 wires 2 Circuits , 20 amps each (Circuit 1 & 2 Only) 13 Duplex receptacles per circuit maximum.26-15 amps Duplex per Power Entry maximum.Easy to install and reconfigure.UL listed as a Manufactured Wiring systemAll Components come in optional Plastic flexible Conduit or Steel flexible Conduit

Ahrend Ltd. - 27 november 2009 66

Electrical Solution – 4 Circuit – Cable t ray Mounted Solut ion

Used for Benching solution to provide shared power down the spine so both sides have access to electrical outlets. UL approved Panel based Byrne Electrical components allow us to install a more robust electrical solution for denser workstation environments. 8 Wires 4 circuits with Dedicated ground and NYC Code Infeeds for work in New York City. These components are mounted to the cable tray creating a Code compliant solution for the Bench.

Ahrend Ltd. - 27 november 2009 7

A500 Benching – uses Cable t rays to secure the shared elect r ical solut ions w hich m akes it UL approved

Standard 8”w Bench Cable Tray

Extra Capacity 14”w Cable tray

Ahrend Ltd. - 27 november 2009 88

Clamps off the beams secure the 8”tray at the center of bench for access to both sides for Electrical & Data solutions

A5 0 0 Benching Solut ion – 8 ” t ray

Ahrend Ltd. - 27 november 2009 99

Photos show the m ount ing of the 1 4 ” Extra Capacity t ray

A5 0 0 Benching Solut ion – for 1 4 ” tray

Ahrend Ltd. - 27 november 2009 1010

A5 0 0 Data Socket Solut ion

A500 Data socket

Housing for Data solution in a Data AccessoryA Faceplate with an A500 beam clamp to attach socket to furniture No Wiring provided by AhrendWires and outlets by others

Ahrend Ltd. - 27 november 2009 1111

A5 0 0 Data Socket Solut ion

Data socket fixed to A500 beam

Ahrend Ltd. - 27 november 2009 1212

Please contact us for m ore inform at ionAhrend Sales Rep: Ingrid Narvaez [email protected]