©2000 general digital corporation1
TRANSCRIPT
![Page 1: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/1.jpg)
©2000 General Digital Corporation
1
www.GenDig.com
![Page 2: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/2.jpg)
©2000 General Digital Corporation
2
System Overview• 20.1" Diagonal Active Viewing Area
• SXGA (1280 x 1024 pixels) Resolution
• Sunlight Readable (1000+ nits)
• High Contrast (~ 6:1 @ 6000 ft-candles)
• Flicker-Free Brightness 0.5 nits to Max
• Designed and Manufactured in U.S.A.
![Page 3: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/3.jpg)
©2000 General Digital Corporation
3
System Overview• Local and Remote Brightness Control• Very Low Specular & Diffuse Reflection• BIT/Failure LED Indicators• System Performance/Failures Recorded in
Non-Volatile Memory (Date & Time Stamped)• Field Replaceable Electronic Components• FCC Class A & UL1950 Approvals
![Page 4: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/4.jpg)
©2000 General Digital Corporation
4
Special Features• SmartBright™ Backlight Assembly
• Intelligent Backlight Controller™
• Icarus “Identify and Replace Before Fail” Software
• CoolBright™ Cooling System
![Page 5: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/5.jpg)
©2000 General Digital Corporation
5
SmartBright™ Features/Benefits• Interleaved Bulbs
- Singular bulb failures do not affect brightness uniformity or display functionality (Soft Failure).
• Redundant Backlight Inverter
- Each inverter drives half of the interleaved bulbs.
- Singular inverter failure reduces display brightness to 50% (Soft Failure).
- Uniform brightness across display is maintained.
![Page 6: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/6.jpg)
©2000 General Digital Corporation
6
SmartBright™ Features/Benefits
• Brightness Limited to 1000 nit by IBC– Increases bulb life expectancy.
• Capable of Generating >1300 nits Brightness- Provides “headroom” for eventual bulb decay.
• Failure Reporting to IBC- Inverter Over-Current or Under-Current- Bulb Decay (50 nit increments), Bulb Failure- Backlight Temperature
![Page 7: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/7.jpg)
©2000 General Digital Corporation
7
IBC Features/Benefits• The Intelligent Backlight Controller (IBC)
augments the UltraBright backlight assembly. It offers:– Advanced System Control, – Alert, – System Monitoring, and – Data logging capabilities.
![Page 8: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/8.jpg)
©2000 General Digital Corporation
8
IBC Control Features • Digital Dimming Control
– Maintains a peak brightness of 1000 nits at the LCD surface (before contrast filters)
• Continuously monitors and adjusts brightness for bulb decay* and temperature changes.
• Augments performance consistency.
* CCFT tubes typically decay 10% during first 2000 hours of operation due to the following:
» Impurities in the fill gas» UV degradation» Tube blackening
![Page 9: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/9.jpg)
©2000 General Digital Corporation
9
IBC Control Features • Digital Dimming Control (Cont’d)
– Flicker-free control from 0.5 nits to max brightness.
– Automatically executes SmartBright™ brightness dimming algorithm in response to over-temp condition.
• System power consumption and internal heat reduced by dimming backlights until over-temp condition is eliminated.
• Intelligent response prevents critical failure to electronics without interrupting operation. (Soft Failure)
![Page 10: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/10.jpg)
©2000 General Digital Corporation
10
IBC Control Features • Thermal Control
– Activates cooling fans after internal ambient reaches programmable “set point”, allowing SmartBright™ bulbs to warm up quickly to maximum brightness from cold start.
– Fan Speed is thermally controlled to reduce excessive noise (40dB max).
– Reduces power consumption/heat dissipation in response to over-temp condition.
![Page 11: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/11.jpg)
©2000 General Digital Corporation
11
IBC Control Features • BIOS Upgrades
– Performance upgrades can be performed quickly and easily in the field thru the use of Icarus software.
– Upgrades can be done while the display is still operational thereby minimizing inconvenience.
• Service/Warranty Update– Password protection of component serial numbers and
warranty information ensure only authorized repairs.
![Page 12: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/12.jpg)
©2000 General Digital Corporation
12
IBC Alert Features • Built-in Test (BIT)/Failure LEDs
– Visual self-health indicators (tri-state LEDs) alert operators of failure conditions and assist troubleshooting.
» Power Good » Temperature Good
» Video Standby » Temperature Warning
» Video Ctlr Failure » Over-Temperature
» Fan Failure » Inverter Failure
– More detailed data is recorded in NVRAM for retrieval by Icarus software.
![Page 13: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/13.jpg)
©2000 General Digital Corporation
13
IBC Monitoring Features
» Bulb Brightness » Fan Operation» Bulb Decay » Inverter Current» Backlight Temp (Current) » Power Supply Voltages» Backlight Temp (Max) » Runtime Hours (System)» Backlight Temp (Min) » Runtime Hours (Fans)» Ambient Temp (Current) » Video Controller Operation» Ambient Temp (Max) » Video Standby» Ambient Temp (Min) » Remote Brightness Sense
![Page 14: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/14.jpg)
©2000 General Digital Corporation
14
IBC Data Logging • All event data is date & time stamped in NVRAM.• Data is retrievable using Icarus/Daedalus Software.• Other Data Recorded:
– Warranty Date of Individual Components » Password protected to allow updates for repair/replacement.
– Date of Manufacture– Serial Number of Components and System– IBC BIOS Revision– NVRAM Available
![Page 15: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/15.jpg)
©2000 General Digital Corporation
15
Icarus Overview• Promotes “Intelligent Replacement Before Fail”.• Upload data to General Digital’s National Database
- Facilitates failure trend analysis at design and component level.- Facilitates customer notification of BIOS revisions and
other product enhancements.- Assists service technicians in diagnosis & troubleshooting.
• Upload BIOS Revisions to Enhance Performance.• Update Serial # and Install Dates for Replaced Components
- Authorization/password obtained from GDC service department.- Warranty information is updated at GDC to reflect replacement of
components.
![Page 16: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/16.jpg)
©2000 General Digital Corporation
16
Icarus User Interface • User can download
and view data from an IBC to analyze performance.
• Data is saved to disk for archiving and performance trend analysis.
![Page 17: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/17.jpg)
©2000 General Digital Corporation
17
Icarus User Interface• Printable report for
off-line viewing.• Report Includes:
– Unit serial number
– Date data was obtained
– System events
![Page 18: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/18.jpg)
©2000 General Digital Corporation
18
Icarus User Interface• View serial numbers
and warranty expiration dates for components.
• Update serial numbers and installation dates for replaced components.
![Page 19: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/19.jpg)
©2000 General Digital Corporation
19
Daedalus Expert System Upgrade• More in-depth information
about current and future system status.
• Detailed solutions to current problems.
• Analyzes available data to recommend replacement of problem components before failure.
![Page 20: ©2000 General Digital Corporation1](https://reader036.vdocuments.site/reader036/viewer/2022072005/56649cd85503460f949a054d/html5/thumbnails/20.jpg)
©2000 General Digital Corporation
20
Character Smoothing
Aliasing
Anti-Aliasing