(1)Start lasers, then find sample using VIS
![Page 2: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/2.jpg)
(2)Set configuration using LSM
![Page 3: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/3.jpg)
(3)Set scan resolution, speed & repetition in Mode
Initial pixal number, scan speed, averaging, zoom and pinhole size are set in stored configurations. These should be optimised after preliminary images.
![Page 4: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/4.jpg)
(4)Set pinhole, excitation & detection for each Channel
Single track
Multi trackUse Find to get initial image, Split and Palette to adust
![Page 5: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/5.jpg)
(5)Control Zoom and Crop in Mode and Select
![Page 6: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/6.jpg)
(6)Set Z stack with first/last & optical slice
![Page 7: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/7.jpg)
(7)Display 3D using projection
![Page 8: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/8.jpg)
(8)Open database for image retrieval
![Page 9: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/9.jpg)
(9)Time Series and Edit Bleaching
![Page 10: (1)Start lasers, then find sample using VIS. (2)Set configuration using LSM](https://reader030.vdocuments.site/reader030/viewer/2022032704/56649d6b5503460f94a4a0da/html5/thumbnails/10.jpg)
(10)Using Lambda stacks, Save to Spectra DB for Linier Unmixing