1961-62 corvettestatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62...

12
901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 1 OF 11 1961-62 CORVETTE CONTROL PANEL CONVERSION KIT 473160 an ISO 9001: 2008 Registered Company TEMP 12 1 2 3 4 5 7 8 9 10 11 AIR FAN DEFROSTER PULL HI

Upload: others

Post on 21-Mar-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 1 OF 11

1961-62 CORVETTE CONTROL PANEL CONVERSION KIT

473160

an ISO 9001: 2008 Registered Company

TEMP

12 1

23

4

57

8

910

11

AIR

FANDEFROSTER PULL

HI

Page 2: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

2901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 2 OF 11

PAGES

Table of Contents

1. COVER 2. TABLE OF CONTENTS 3. PACKING LIST/ PARTS DISCLAIMER 4. OEM CENTER CONSOLE HEATER CONTROL BEZEL 5. ROTARY POT INSTALLATION 6. FINAL STEPS 7. CONTROL PANEL CALIBRATION PROCEDURE 8. CONTROL PANEL CALIBRATION PROCEDURE CONT. 9. WIRING DIAGRAM10. OPERATION OF CONTROLS11. CONTROL PANEL KIT PACKING LIST

Page 3: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

3901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 3 OF 11

CONTROL KIT473160

No QTY PART No. DESCRIPTION

1. 2. 3. 4. 5. 6. 7. 8. 9.

313251312

246018-0232002-VUA49700318601121301-VUP23152018399-VUB117000117001

ROTARY POT ASMGEN IV UNIVERSAL CONTROL HARNESSKNOB, ALUMINUM FLUTEDWASHER .625 OD x .281 ID4” TIE WRAPGROUND WIRE4-40 X 3/16 SOCKET SET SCREWADAPTER, 58-62 CORVETTE CONTROL POT UPPERADAPTER, 58-62 CORVETTE CONTROL POT LOWER

** BEFORE BEGINNING INSTALLATION OPEN ALL PACKAGES AND CHECK CONTENTS OF SHIPMENT. PLEASE REPORT ANY SHORTAGES DIRECTLY TO VINTAGE AIR WITHIN 15 DAYS. AFTER 15 DAYS, VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS.

1

45 6 7 8 9

2 3

Page 4: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

4901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 4 OF 11

ROTARY POT CONTROL CONVERSIONINSTRUCTIONS FOR1961-62 CORVETTE

OEM CENTER CONSOLE HEATER CONTROL BEZELDISCONNECT CABLES, WIRES FROM BACK OF CONTROL BEZEL. REMOVE OEM CONTROL BEZEL.

OEM CENTERCONSOLE HEATERCONTROL BEZEL

TEMP

12 1

23

4

57

8

910

11

AIR

FANDEFROSTER PULL

HI

Page 5: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

5901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 5 OF 11

ROTARY POT INSTALLATIONCUT 1/8” SLOT IN OEM DEFROSTER PULL FAN HOLE IN CONTROL BEZEL. SEE BELOW. LOCATE THE (3) ROTARY POT ASSEMBLIES, AND INSTALL IN OEM CONTROL BEZEL AS SHOWN BELOW.TIE WRAP WIRES TO ROTARY POTS AS SHOWN.INSTALL CONTROL KNOB AS SHOWN BELOW.

WHTWHT/GRNRED

TOP VIEW

SET SCREW

ROTARY POTSHAFT

FAN

MODE TEMP

WHTWHT/YELRED

WHTWHT/REDRED

(3) CONTROLKNOBS497003

TIE WRAP

(3) NUTS

(2) WASHERS

OEMCONTROL

BEZEL

(2) CONTROL POT ADAPTER

LOWER117001

ORIENTATION OFWIRING

CONTROL POT ADAPTER

UPPER117000

ORIENTATION OFWIRING

(3) ROTARY POTASM

246018-0

CUT 1/8”SLOT

1/8

1/8

BACK SIDEOF CONTROL

PANELOEM DEFROSTERPULL FAN HOLE

SETSCREW

SET SCREW

Page 6: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

6901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 6 OF 11

PLUGFROM

CONTROLWIRING

HARNESS232002-VUA

PLUGFROM

WIRINGHARNESS

232001-VUR

PLUG THE WIRING HARNESS INTO THE ECU MODULE ON SUB CASE. SEE BELOW.WIRE ACCORDING TO WIRING DIAGRAM ON PAGE 9.TO CALIBRATE THE CONTROLS FOLLOW THE CALIBRATION PROCEDURES ON PAGES 7 & 8.

12 1

23

4

57

8

910

11

AIR

LO HI

TEMP.

DEFROSTER PULLFAN

FINAL STEPS

Page 7: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

7901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 7 OF 11

On Vintage Air Gen IV systems using factory controls, it is necessary to calibrate the system to your specific control panel. This procedure ensures that the stroke of your control panel levers or knobs is translated into precise control of the fan speed, temperature blend and mode door position. Please carefully read and understand these procedures before beginning. The procedure may be repeated as many times as necessary to get it right.

In preparation for calibration, you will need to attach the supplied white ground jumper wire to a suitable chassis ground. This jumper wire must be easily connected to the gray programming wire located in the main Gen IV wiring harness next to the relays. During the calibration procedure, you will connect the white jumper to the gray program wire, which will “teach” the Gen IV ECU the upper limits of the control levers or knobs. The blower will momentarily change speeds, signaling that the upper limits have been “learned”. You will move the levers or knobs to opposite extreme positions of their travel and then disconnect the white jumper. The blower will again change speeds, signaling that the lower limits have been learned and that the calibration procedure is complete.

Control PanelCalibration Procedure

GrayProgram Wire

White JumperCable

Page 8: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

8901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 8 OF 11

TURN THE IGNITION SWITCH ON (DO NOT START THE ENGINE)

MOVE THE FAN SWITCH (IF USED) AND CONTROL KNOBS TO THE POSITION SHOWN.

CONNECT THE WHITE JUMPER WIRE TO THE GRAY PROGRAM WIRE. WAIT FOR THE BLOWER SPEED TO CHANGE. (APPROXIMATELY 5 SECONDS)

MOVE THE FAN SWITCH AND CONTROL KNOBS TO THE POSITIONS SHOWN

DISCONNECT THE WHITE JUMPER WIRE FROM THE GRAY PROGRAM WIRE. THE BLOWER SPEED WILL CHANGE, INDICATING COMPLETION OF THE CALIBRATION PROCEDURE.

CONFIRM PROPER OPERATION OF CONTROLS. REPEAT PROCEDURE IF NECESSERY. WHEN FINISHED, TAPE OVER PROGRAM WIRE CONNECTER WITH ELECTRICAL TAPE TO PREVENT ACCIDENTAL CONTACT WITH CHASSIS GROUND.

CONTROL PANEL CALIBRATION PROCEDURE CONT.

OFF ON

START

AIR

12 1

23

4

57

8

910

11

LO HI

TEMP.

DEFROSTER PULLFAN

AIR

12 1

23

4

57

8

910

11

LO HI

TEMP.

DEFROSTER PULLFAN

Page 9: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

9901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 9 OF 11

WHT/GRN

WHT/YELWHT/RED

RED

WHTBACKLIGHT NEG

FAN WIPER

MODE WIPER

TEMP WIPER

5V-SW

GND

BACKLIGHT POS

AC ANNUNCIATOR

PRE-WIRED

GEN IV WIRING DIAGRAMREV D, 5/6/2014

GEN IV ECU

PROGRAM

Wiring Diagram

TEMP

MODE

FAN

A/C(IF USED)

232007-VUR

232002-VUA

** CIRCUITBREAKER30 AMP

*** WIDE OPENTHROTTLESWITCH

(OPTIONAL)

* DASH LAMP(IF USED)

Dash Lamp Is Used Only With Type 232007-VUR Harness.Warning: Always Mount Circuit Breaker As Close to the Battery As Possible. (NOTE: Wire BetweenBattery and Circuit Breaker Is Unprotected and Should Be Carefully Routed to Avoid a ShortCircuit).Wide Open Throttle Switch Contacts Close Only at Full Throttle, Which Disables A/C Compressor.

JF8

BLK

ORA

TAN

VIEWED FROM WIRE SIDE

••

HEATERCONTROL VALVE

Page 10: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

10901041 REV C 04/13/15, INST 1961-62 VETTE CNTRL PNL PG 10 OF 11

OPERATION OF CONTROLS

THIS KNOB CONTROLSTHE BLOWER SPEED,

FROM OFF TO HI

BLOWER SPEED

ROTATE THE KNOB TOTHE LEFT TO DIRECT AIR

FLOW TO THE DASH VENTS

MODE KNOB

TEMPERATURE KNOB IN A/C MODE ROTATE

THE TEMPERATURE KNOBALL THE WAY LEFT TO

THE COLD POSITION TOENGAGE COMPRESSOR.(ROTATE KNOB LEFT OR

RIGHT TO ADJUST DESIRED TEMPERATURE)

ROTATE KNOB RIGHTTO DESIRED BLOWER

SPEED FROM OFF TO HI.

BLOWER SPEED

ROTATE THE KNOB TOTHE RIGHT TO DIRECT

AIR FLOW TO THE DEFROST VENTS.

MODE KNOB

TEMPERATURE KNOBROTATE KNOB RIGHTTO DESIRED BLOWER

SPEED FROM OFF TO HI.

BLOWER SPEED

ROTATE THE KNOB TO THE CENTER TO

DIRECT AIR FLOW TO THE FLOOR.

MODE KNOB

TEMPERATURE KNOBIN HEAT MODE ROTATE

THE TEMPERATURE KNOB ALL THE WAY RIGHT TO

THE HOT POSTION. (ROTATE KNOB LEFT

OR RIGHT TO ADJUST DESIRED TEMPERATURE)

ROTATE KNOB LEFT OR RIGHT TO ADJUST

DESIRED TEMPERATURE.(COMPRESSOR IS AUTOMATICALLY

ENGAGED)

THE TEMPERATURE KNOB TOGGLES BETWEEN A/C AND HEAT MODES. FOR A/C MODE ROTATE THE TEMPERATURE KNOB ALL THE WAY LEFT. FOR HEAT MODE ROTATE THE KNOB ALL THE WAY TO THE RIGHT TO DISENGAGE THE COMPRESSOR, THEN MOVE THE KNOB TO SELECT DESIRED TEMPRERATURE.

NOTE: EACH TIME THE SYSTEM TOGGLES BETWEEN MODES, THE BLOWER WILL MOMENTARILY CHANGE SPEEDS.

ALL SWITCHES ARE VARIABLE BETWEEN POSITIONS, SYSTEM WILL PERFORM A BLEND BETWEEN THE FUNCTIONS.

BLOWER SPEED

MODEKNOB

A/C MODE

TEMPERATUREKNOB

12 1

23

4

57

8

910

11

OFF

DASH

FLOOR

DEF COLD HOT

HI

DEFROSTER PULLFAN

AIR

12 1

23

4

57

8

910

11

LO HI

TEMP.

DEFROSTER PULLFAN

AIR

12 1

23

4

57

8

910

11

LO HI

TEMP.

DEFROSTER PULLFAN

HEAT MODEDEFROST/ DE-FOG

MODE

Page 11: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster
Page 12: 1961-62 CORVETTEstatic.speedwaymotors.com/pdf/725961060-2.pdf901041 rev c 04/13/15, inst 1961-62 vette cntrl pnl pg 5 of 11 rotary pot installation cut 1/8” slot in oem defroster

901041 REV C 04/13/15, 1961-62 VETTE CNTRL PNL INSTR PG 11 OF 11

CONTROL KIT473160

No QTY PART No. D CHECK LISTESCRIPTION

CHECKED BY:PACKED BY:

DATE:

1

4 5 6

2 3

1. 2. 3. 4. 5. 6. 7. 8. 9.

313251312

246018-0232002-VUA49700318601121301-VUP23152018399-VUB117000117001

ROTARY POT ASMGEN IV UNIVERSAL CONTROL HARNESSKNOB, ALUMINUM FLUTEDWASHER .625 OD x .281 ID4” TIE WRAPGROUND WIRE4-40 x 3/16 SOCKET SET SCREWADAPTER, 58-62 CORVETTE CONTROL POT UPPERADAPTER, 58-62 CORVETTE CONTROL POT LOWER

7 8 9