with 2x vertical collectors connected in the center 1 2 Mounting structures 2 1 Shield 3 8 Brass rein- forcement 4 2 Shield angle connectors 5 27 Steel Nut Μ8 6 19 Steel screw Μ8χ12 7 4 Plastic expansion D10 8 4 Hanger bolts 9 1 Short inox hose 10 2 Steel Washer Μ8Χ24 11 1 Brass elbow 3/4’’ 12 1 Long inox hose 14 8 17 2 Brass T with O-rings 18 4 Rubber Gasket 20 21 22 2 Steel washer Μ8Χ16 Anti-freeze liquid Brass plug with O-ring 17 Step 18 Step 19 Step 16 Step 20 Step 8 1 4 12 1 9 1 17 1 17 1 18 1 18 1 3 2 3 2 15 1 13 1 16 1 21 1 Support beams for 2x collectors Stud Μ8Χ20 A. First screw the studs on the movable metallic nuts on the lower side of the collector then apply the collector on the support structure and tight with washers and nuts. Β. First check that the front part of the solar system looks to the South and then pierce the floor. C. In case the collector has extra outlets, then you have to tap them, according to step 16. D. Check that you fullfill the closed circuit of the solar system with water and antifreeze liquid according to the instruc- tions indicated on the label of antifreeze liquid and then screw the expansion tank EMPTY and the pressure relief valve with use of teflon insulation. Ε. Check before leaving the installation site that all bolts are properly tightened and all piping are properly connected without leaking. F. ATTENTION! The connection of the backup heating element must be done by experienced personnel. 11 1 9 1 18 1 12 1 18 1 19 13 1 Non-return pressure valve 15 1 Expansion tank 16 1 Pressure relief valve Technical Manual For the installation of a solar system Inlet of hot liquid from collector Outlet of cold liquid to collector Screw it tight with the use of teflon insulation Alternative position of the pressure-relief valve and the expansion tank in case of one tube on top of the tank. (instead of 2 tubes) Regulator of backup heat- ing element to 60 ο C Screw it tight with the use of teflon insulation 3 4 22 4 ATTENTION! See note C 23 2 Mounting X

Upload: others

Post on 04-Jun-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 16 Inletfrom collector of hot liquid Outlet Technical Step

with 2x vertical collectorsconnectedin the center

12Mounting

structures

21Shield

38Brass rein-

forcement

42Shield angle

connectors

527Steel Nut

Μ8

619Steel screw

Μ8χ12

74Plastic expansion

D10

84Hanger bolts

91Short inox hose

102Steel Washer

Μ8Χ24

111Brass elbow

3/4’’

121Long inox hose

148

172

Brass T with O-rings

184Rubber Gasket

20

21 22

2 Steel washer Μ8Χ16

Anti-freeze liquid

Brass plug with O-ring

17Step

18Step

19Step

16Step

20Step

8

1 4

121 91171 171181 181

3232

151131161 211

Support beams for2x collectors

Stud Μ8Χ20

A. First screw the studs on the movable metallic nuts on the lower side of the collector then apply the collector on the support structure and tight with washers and nuts. Β. First check that the front part of the solar system looks to the South and then pierce the floor.C. In case the collector has extra outlets, then you have to tap them, according to step 16.D. Check that you fullfill the closed circuit of the solar system with water and antifreeze liquid according to the instruc-tions indicated on the label of antifreeze liquid and then screw the expansion tank EMPTY and the pressure relief valve with use of teflon insulation.Ε. Check before leaving the installation site that all bolts are properly tightened and all piping are properly connected without leaking.

F. ATTENTION! The connection of the backup heating element must be done by experienced personnel.

11191

181121181

19

131Non-return

pressure valve

151Expansion

tank

161Pressure relief

valve

TechnicalManualFor the installation of a solar system

Inlet of hot liquid from collector

Outlet of cold liquid to collector

Screw it tight with the use of teflon insulation

Alternative position of the pressure-relief valve and the expansion tank in case of one tube on top of the tank. (instead of 2 tubes)

Regulator of backup heat-ing element to 60ο C

Screw it tight with the use of teflon insulation

34224

ATTENTION!See note C

232Mounting X

Page 2: 16 Inletfrom collector of hot liquid Outlet Technical Step

6252

6252

THIS SIDE OUT

2Step

5Step 64

54

62

1Step

3Step

61

232

51

4Step

6Step

7Step

9Step

N

S

E

SESW

W

χ χ

8Step

10Step

8474

11Step 52

42

62

12Step

6252

10221

13Step

14Step

6252

15Step

ATTENTION!See note A

64192

144

144

54

54

204

204

54

Move and place the mounting structures in the correct orientation and then align and center the collectors on the structures.

Press the center of the shield in order to curvature it like in step 14

example

2 items from object 6

Outlet of hot water for use

Inlet of cold water from water network

Backup heating elementInlet of hot

liquid from collector