1260 infinity ii lc presentation - agilent.com · marketing director. agenda. 1260 infinity ii...

33
The new 1260 Infinity II LC New InfinityLab LC Series Workflow Solutions AGILENT THE PREMIER LABORATORY PARTNER FOR A BETTER WORLD Dr. Martin Vollmer Marketing Director

Upload: others

Post on 14-Jul-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

The new 1260 Infinity II LC New InfinityLab LC Series Workflow Solutions

AGILENT THE PREMIER LABORATORY PARTNER FOR A BETTER WORLD Dr. Martin Vollmer

Marketing Director

Page 2: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Agenda

1260 Infinity II Automated Multimethod and Method Development

1260 Infinity II Bio-inert LC

1260/1290 Infinity II GPC Solution

Page 3: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Pre-defined personalized methods

InfinityLab LC Solutions

Multiple users

One power user Automated method

development

1260 Infinity II (600 bar) 1290 Infinity II (1300 bar)

Method Development Solution

Multi Method Solution

One Hardware Setup

One Hardware Setup – Two Solutions

Method Scouting Wizard A.02.06 Autom. sequence setup

Runtime optimization

Reporting

OpenLab CDS Lab-at-a-glance view

Full compliance with GLP, GMP

Intelligent Reporting

Page 4: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Method Development

min 0.5 1 1.5 2 2.5 3 3.5

mAU

0

10

20

Eclipse plus C18

min 0.5 1 1.5 2 2.5 3 3.5

mAU

0

10

20

Eclipse plus PhenylHexyl

min 0.5 1 1.5 2 2.5 3 3.5

mAU

0

10

20

Bonus RP

R = ¼ 𝑁(a-1)(k/[1+k])

Changes of a have a much higher effect than changes of N !

Why different separation conditions?

Page 5: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Hardware and Columns

Choose from our InfinityLab column and consumables repertoire to set up your method development system

Automated Method and

Sequence Setup

Use Method Scouting Wizard for automated sequence setup optimizing time and solvent consumption

Data Acquisition and Run Control

Discover reliable and convenient data acquisition using OpenLab ChemStation

Reporting and Data Processing

Discover the new Method Scouting Wizard reporting functions to create individual reports

InfinityLab Method Development Solutions Solutions that cover your complete workflow

Page 6: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Exploring possibilities in Method Development

Four columns in one MCT Eight columns per MCT, clustering of up to four MCT

DT

Two temperature zones per MCT, up to four MCT

DT

Two independent temperature zones

1260 Infinity II Method Development 1290 Infinity II Method Development

Column Capacity

Temperature Zones

> 600 different applicable conditions > 5400 different applicable conditions

Two solvent selection valves (26 mobile phases)

A B C D

Two solvent selection valves (26 mobile phases)

A B C D

External Solvent Selection Valves

Page 7: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Multicolumn Thermostat – To Serve Multiple Columns

New 1260 Infinity II Multicolumn Thermostat with simplified access, easy and flexible to install Quick Connect heat exchangers and Quick Change Valves.

Superior access to heat exchangers, valves and columns

Page 8: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

1260 Infinity II Multicolumn Thermostat

• Usability Easily find column details

• Traceability Always know exactly which columns are installed and in use

• Security Protect against the use of methods incompatible with the column

Understand key details and record usage of the multiple columns with your LC system. Avoid mistakes and plan for exchange when needed

New column tag reader for a wide range of pre-labeled InfinityLab Poroshell columns

Page 9: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

InfinityLab Series Improves Usability

The new Quick Change heat exchangers can be installed in

seconds by turning just two clips. There is no capillary attached

that could break.

Technology: Quick Connect heat exchangers

New concept of Multicolumn Thermostat Heat Exchangers

Page 10: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

InfinityLab Valve Options

Technology: Quick Change Valves

Column selection valves

1260 Infinity II Method Development system comes with new 4-column selector valve – also supported by Method Scouting Wizard SW

Page 11: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

The New Agilent 1260 Infinity II LC!

Analytical Efficiency for ultimate confidence in your data!

Analytical Efficiency – Low Dispersion Connections

Dispersion optimized: InfinityLab Quick Connect and Quick Turn fittings

not only add usability when installing columns, with their spring loaded

mechanism they also help effectively reducing dispersion.

Thus, improving chromatographic results.

Page 12: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Method Development Software Solutions

selected column is shown directly in the instrument control

no need to deal with individual valve positions

Column centric view for more usability

Page 13: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Agilent ChemStation Method Scouting Wizard

• Define project Choose scouting combinations and base method.

• Select columns All installed columns are shown automatically.

• Select solvents Pump types and valves are automatically detected.

• Define gradients Select between different gradients and temperatures.

• Review and select screening methods Check for incompatible combinations.

• Set up samples Define injection volumes and number of repetitions.

Easy and fast setup of sequences !

The easy way to set up even complex screening campaigns

Page 14: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

With MSW A.02.06, 1290 Infinity II Method Development can also be combined with

ISET

Cross-System Method Transfer Solution

*

Flexible High Speed

1290 Infinity II LC

MSW and Intelligent System Emulation Technology (ISET)

Fast method transfer: 1) Method development on

1290 Infinity II system without ISET

2) Method translation using ISET, fine tuning on target system

Advanced method transfer: 1) Emulation of target system

using ISET 2) Method Development in

ISET mode 3) Transfer of complete

method to target system

Page 15: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

1260 Infinity II Automated Multimethod and Method Development

1260 Infinity II Bio-inert LC

1260/ 1290 Infinity II GPC solution

Page 16: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

New Agilent 1260 Infinity II Bio-inert LC

True bio-inertness – 100% metal-free sample flow path

New detectors (improved specifications)

New Column Compartment (ease-install bio-inert heat exchanger, Quick Connect bio-inert fittings)

New bio-inert Multisampler (ideal for microtiter plate based workflows, high capacity, faster, lowest carry-over)

New bio-inert pump (improved usability, full backwards method compatibility)

Page 17: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

1260 Infinity II Bio-inert LC

• Universality (U)HPLC system for small- and large-molecule analysis

• Multiple Attribute Analysis Fast switching between different columns and chromatography modes

• Highly Robust Corrosion resistant and widest pH range

• Small scale purification Fraction collection up to 10 mL/min

Stainless steel system

1260 Infinity Bio-inert LC

True bio-inertness – 100% metal-free sample flow path

Page 18: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

New Agilent 1260 Infinity II Bio-inert Multisampler

100% Bio-inert

Precious sample does not touch any metal surface

Lowest carryover

Single digit (9 ppm) using Multi-Wash feature active seat backflush

Efficient temperature control

For temperature-sensitive samples avoiding degradation

Highest capacity at lowest bench space

6144 samples within Agilent LC footprint - Single height drawers - Dual height drawers - Triple height drawers

Highest flexibility, ultralow carry-over and 100% metal free - for your bio applications

Page 19: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

New Agilent 1260 Infinity II Bio-inert Heat Exchangers

100% Bio-inert Metal-free heat exchangers

New 1260 MCT for Multimethod Multi-Attribute Analysis

New bio-inert Quick Change 4-column selection valve Multi-attribute analysis and automated Method Development

Maximum application flexibility

Peltier cooling and heating with two independent temperature zones from 10 °C below ambient up to 85°C

Ease of use Prepared for InfinityLab Quick Connect fittings; flexible flap positions: open door to 90° (desk function), to 180° or even remove door for best accessibility

Designed to fit in new MCT

Page 20: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Agilent BioColumns Portfolio

Agilent Bio-LC Columns

Affinity

Bio-Monolith Protein A

Bio-Monolith Protein G

Reversed Phase

AdvanceBio Peptide Mapping ZORBAX RRHD

300A 1.8µm

Poroshell 300

AdvanceBio RP mAb

ZORBAX 300SB

ZORBAX Amino Acid Analysis

PLRP-S

AdvanceBio Oligonucleotide

HILIC

AdvanceBio Glycan Mapping ZORBAX RRHD

300-HILIC

Size Exclusion

AdvanceBio SEC

Bio SEC-3

Bio SEC-5

ProSEC 300S

ZORBAX GF-250

ZORBAX GF-450

Ion Exchange

Bio-Monolith (QA, DEAE, SO3)

Bio mAb

Bio IEX (SAX, SCX, WAX, WCX)

PL-SAX

PL-SCX

Page 21: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

AdvanceBio SEC Delivers High Resolution of mAb Impurity Profile for Better Accuracy

AdvanceBio SEC 2.7 um 300A, 7.8 x 300 mm

Competitor A: 4um, 7.8 x 300 mm

min 5 10 15

mAU

0

100

200

300

400

min 5 10 15

mAU

0

100

200

300

400

min 5 10 15

mAU

-2

-1

0

1

2

min 5 10 15

mAU

-2

-1

0

1

2

Page 22: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

AdvanceBio SEC Delivers Improved Peak Shape for an ADC with New Bonded Phase

AdvanceBio SEC 2.7 um 300A

Competitor 5um,

7.8 x 300 mm

Competitor 4um, 7.8 x 300 mm

Competitor 3um, 7.8 x 300 mm

min 5 10 15

mAU

0 100 200 300 400 500 600 700

min 5 10 15

mAU

0 100 200 300 400 500 600 700

min 5 10 15

mAU

0 100 200 300 400 500 600 700

min 5 10 15

mAU

0 100 200 300 400 500 600 700

min 6 8 10 12

mAU

0

5

10

15

20

min 6 8 10 12

mAU

0

5

10

15

20

min 6 8 10 12

mAU

0

5

10

15

20

min 6 8 10 12

mAU

0

5

10

15

20

Page 23: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Quaternary Buffer Mixing with Buffer Advisor Ion Exchange Chromatography

Ease of use to setup ion-exchange chromatography

Page 24: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

What is Buffer Advisor?

• Buffer Advisor is an independent utility software to calculate pump time tables for ion-exchange chromatography with the 1260 Infinity II Bio-inert pump

• Provides the foundation for automated mixing of acid, base, water and salt in IEX

• Suggests for the most suitable stock solutions and provides recipes

• Has included more than 50 different buffers and more than 20 were experimentally validated

• Is capable to correct automatically for pH shifts during salt gradients

Ease of use to setup ion-exchange chromatography

Page 25: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

1260 Infinity II Automated Multimethod and Method Development

1260 Infinity II Bio-inert LC

1260/ 1290 Infinity II GPC solution

Page 26: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

The new Agilent 1260 Infinity II LC!

Significantly improved workflow solution!

New Refractive Index Detectors (higher data rate, micro-flow cell available) New Column Compartment (no problem to place long GPC columns, even couple up to four)

New Vialsampler (faster, lower carry-over)

New Isocratic Pump (solvent selection and degassing option)

1260 Infinity II GPC/SEC Solution

Page 27: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Instrument Control

Data Collection

GPC/SEC Calculations

• Same look-and-feel as the OpenLAB CDS ChemStation for HPLC

• Easy to move from one system to another when deploying both techniques

Powerful Agilent GPC Software

Page 28: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

• The Agilent 1260 Infinity II MCT accommodates up to four 30 cm GPC columns

• The 1260 Infinity II Multicolumn Thermostat allows precise column thermostatting over a broad temperature independent of surroundings

• A shift in retention times related to poor temperature control could result in a change in molecular weight of many thousands of daltons

High Precision Temperature Control 1260 Infinity II Multicolumn Thermostat (MCT)

Superior temperature stability and more space to couple up to 4 long columns

Page 29: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Two New Refractive Index Detectors: Comparison

G7162A: Agilent 1260 Infinity II Refractive Index Detector (RID)

G7162B: Agilent 1290 Infinity II Refractive Index Detector (RID)

Replaces the current model, G1362A with higher data rate and “RoHS compliant”

A new product introduction with a small volume cell and higher data rate

Page 30: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Increase GPC Productivity with the 1290 Infinity II RID

Epoxy resin

Achieve shorter run times:-

1.2ml/min

0.3ml/min

0.6ml/min

2.5 µL low volume flow cell Maximum data rate of 148 Hz Narrow internal diameter columns (4.6 x 250mm)

Resolution maintained at a fourth of run time

Page 31: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Case Study – Customer Sample “Kraton”

Sta

50min

Standard GPC columns & Conventional RI Customer wanted to reduce

runtime and maintain resolution

Narrow-bore GPC columns & Conventional RI

Loss of resolution with shorter run time & conventional RID

Resolution achieved using standard GPC columns & micro RID

Narrow-bore GPC columns & Micro RID

15min

4 columns individual pore

sizes 7.5mmx300mm

2 columns ResiPore

4.6mmx250mm

2 columns ResiPore

4.6mmx250mm

µRID

Standard RID

15min

Standard RID

More resolution for polymer samples

Page 32: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

A comprehensive GPC solution, the complete workflow for polymer characterization supplied and supported by Agilent

New Agilent 1260 Infinity II GPC!

Page 33: 1260 Infinity II LC Presentation - agilent.com · Marketing Director. Agenda. 1260 Infinity II Automated Multimethod and Method Development . ... Avoid mistakes and plan for exchange

Thanks for your attention!!!!