The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory MutualResearch Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.

Products manufactured and distributedby Reliable have been protecting life and property for over 80 years, and are installed and servicedby the most highly qualified andreputable sprinkler contractors located throughout the United States, Canada and foreign countries.

The Reliable Automatic Sprinkler Co., Inc.

(800) 431–1588 Sales Offices(800) 848–6051 Sales Fax(914) 829-2042 Corporate Officeswww.reliablesprinkler.com Internet Address

Manufactured by

Model G & F1 - Open Standard (Spray) Uprightand Pendent SprinklersModels G and F1 standard upright and pendentsprinklers distribute water laterally and downward in awide pattern approximating a half sphere. Thishemisphere is completely and uniformly filled with waterin the form of small drops and spray. A circular area, from12 to about 20 ft. (3.7 to 6.1m) in diameter, is covered 10ft.(3.0m)below thesprinklerat minimum water dischargepressure. See Technical Bulletins 110 and 117.

Model F1Standard Upright

Model GStandard Pendent

Model G & F1 - Conventional Open Style Sprinkler This deflector configuration is used primarily in thosecountries where the LPC installation rules haveprecedence. The sprinkler distributes approximately 60%of its water discharge upward against the ceiling with the

balancedownward.It maybe installed in eithertheuprightor pendent position. Sprinklers with conventionaldeflectors are available with orifice sizes correspondingtolight, ordinary and extra–hazard installations.See Technical Bulletins 110 and 117.

Model G & F1 - Open Sidewall SprinklersThis deflector configuration is designed for use wherestandard sprinklers are deemed impartial because ofdecorative or structural conditions. It dischargesapproximately 15% of the water on the wall behind it withthe remaining 85% discharged in front of the sprinkler.

The Model G & F1 Vertical Sidewall Sprinklers may beinstalled in either the upright or the pendent position, andare intended for light hazard occupancy use.

The Model G & F1 Horizontal Sidewall Sprinklers areintended for light hazard occupancies and in someapplicat ions may be used in ordinary hazardoccupancies.See Technical Bulletins 112 and 117.

Model G Vertical Sidewall

Model F1Horizontal Sidewall

For specific water distribution information, refer to thespray distribution section of the catalog.

RecycledPaper

Revision lines indicate updated or new data.

P.G. Printed in U.S.A. 12/06 P/N 9999970003

Model GStandard Conventional

Model F1Standard Conventional

Model F1Standard Pendent

Model GStandard Upright

Model GHorizontal Sidewall