Addendum
WATSON TATE SAVORY, Inc.
1316 Washington Street, Suite 100, Columbia, SC 29201 | 803.799.5181 1307 W. Morehead Street, Suite 101, Charlotte, NC 28208 | 704.749.5181
watsontatesavory.com 1
Date: 05 May 2020
Addendum No. THREE
Project: ARTIFICIAL INTELLIGENCE LAB UPFIT
University of South Carolina
Columbia, South Carolina
WTS # 1919
OSE # H27-Z408
From: Regina R. Floyd, AIA LEED AP BD+C
To: Prospective Bidders / Plan Holders
Addenda are issued prior to execution of Contract. All instructions contained herein shall be reflected in
the Contract Sum and this Addendum will be made a part of the Contract Documents, if, as, and when a
Construction Contract is awarded.
This Addendum forms a part of the Contract Documents and modifies the original documents dated 05
April 2019, as noted below. Acknowledge receipt of this Addendum in this space provided on the Bid Form.
Failure to do so will subject the Bidder to disqualification.
This Addendum consists of 7 pages and the following attachments:
Section 08 8719 – DECORATIVE WINDOW FILM ................................................................................... 4 Pages
Drawing A1.1 – WEST TOWER LEVEL 5 – FLOOR PLAN .......................................................................... 1 Sheet
Drawing A3.2 – INTERIOR ELEVATIONS ................................................................................................. 1 Sheet
Drawing A5.1 – DOOR SCHEDULE AND DETAILS .................................................................................... 1 Sheet
Drawing A1.14A – WEST TOWER - LEVEL 4 – AREA PLAN (For information only) ................................. 1 Sheet
Drawing A2.14A – WEST TOWER - LEVEL 4 – RCP (For information only) ............................................. 1 Sheet
A. GENERAL INFORMATION:
1. DOOR, FRAMES AND DOOR HARDWARE previously noted to have materials provided by Owner
and installed by Contractor have been revised through this Addendum to be both PROVIDED
AND INSTALLED BY CONTRACTOR.
2. Floor and Reflected Ceiling Plans for the existing spaces at Level 4 below are attached and
provided for General Information due to work occurring below slab:
1) Drawing A1.14A – WEST TOWER - LEVEL 4 – AREA PLAN (for information only)
2) Drawing A2.14A – WEST TOWER - LEVEL 4 – RCP (for information only)
06
ARTIFICIAL INTELLIGENCE LAB UPFIT ADDENDUM 03
University of South Carolina May 5, 2020
2
B. REVISIONS TO THE PROJECT MANUAL:
1. TABLE OF CONTENTS:
a. Add the following section:
“08 8719 – DECORATIVE WINDOW FILM .................................................................... 4 Pages
2. SECTION 01 1100 – SUMMARY:
a. Article 1.5 – Material Provided by the Owner: Delete Paragraph B. Doors, Hollow Metal
Frames and Door Hardware will NOT be provided by Owner. Both materials and
installation shall be by Contractor.
3. SECTION 05 1200 – STRUCTURAL STEEL:
a. Article 1.4: Delete Paragraph E “LEED Credit Related Submittals”.
4. SECTION 07 8413 – PENETRATION FIRESTOPPING:
a. Article 1.3: Delete Paragraph B “LEED Submittals”.
5. SECTION 08 1113 – HOLLOW METAL DOORS AND FRAMES:
a. Hollow Metal Doors and Frames Material is ADDED to the contract by this addendum.
Revise note at top of page 1 to read as follows:
“NOTE: ALL HOLLOW METAL DOORS AND FRAMES MATERIAL AND INSTALLATION IS BY
GENERAL CONTRACTOR”.
b. Article 2.3: Revise Item 2.3.B.1.b to read as follows:
“b. Construction: Full profile welded, unless otherwise. Knock down frames may be used
at Shell space doors where noted at Door Schedule.”
6. SECTION 08 1416 – FLUSH WOOD DOORS:
a. Flush Wood Door Material is ADDED to the contract by this addendum. Revise note at top
of page 1 to read as follows:
“NOTE: ALL FLUSH WOOD DOORS MATERIAL AND INSTALLATION IS BY GENERAL
CONTRACTOR”.
7. SECTION 08 4113 – ALUMINUM FRAMED ENTRANCES AND STOREFRONTS:
a. Article 2.1.C: Add the following approved substitution:
“3. Old Castle, Series 3000.”
8. SECTION 08 7100 – DOOR HARDWARE:
b. Door Hardware Material is ADDED to the contract by this addendum. Revise note at top of
page 1 to read as follows:
“NOTE: ALL DOOR HARDWARE MATERIAL AND INSTALLATION IS BY GENERAL
CONTRACTOR”.
9. SECTION 08 8719 – DECORATIVE WINDOW FILM:
a. Add the attached Section 08 8719 to the Project Manual (4 pages).
6,
ARTIFICIAL INTELLIGENCE LAB UPFIT ADDENDUM 03
University of South Carolina May 5, 2020
3
10. SECTION 09 7713 – STRETCHED-FABRIC WALL SYSTEMS:
a. Article 2.3, Paragraph A: Delete reference to FWP-2 & FWP-3. All panels this project will
be FWP-1.
11. SECTION 11 5213 – PROJECTION SCREENS:
a. Page 1 – Add the following note:
“NOTE: PROJECTION SCREENS TO BE PROVIDED BY OWNER AND INSTALLED BY GENERAL
CONTRACTOR.”
C. REVISIONS TO THE DRAWINGS:
1. DRAWING T0.1 – TITLE SHEET & INDEX OF DRAWINGS:
a. OWNER PROVIDED MATERIAL Note (lower right of page): Delete Item 2 – Doors, Hollow
Metal Frames & Door Hardware. These items will NOT be provided by Owner, and shall be
furnished and installed by Contractor.
2. DRAWING S0.1 – GENERAL NOTES, PLANS AND DETAILS:
“APPLIED FIREPROOFING:
1. Steel Beams added for Alternate No. 01 skylight to have spray-applied fireproofing
installed per Section 07 8100 “Applied Fireproofing”. “
3. DRAWING A1.1 – WEST TOWER LEVEL 5 – FLOOR PLAN:
a. Replace with the attached Drawing A1.1, which has been revised as follows:
1) Noted existing metal framed walls to receive 5/8” gypsum wallboard at both sides:
- South wall of Glycol 500A
- South wall of Corridor H501
2) Noted locations for installation of Corner Guard as specified at Section 10 2600
(marked with “CG”).
4. DRAWING A2.1 – WEST TOWER – LEVEL 5 - RCP:
a. Reflected Ceiling Plan: Revise the notation “MP2” at the ceiling above the Tenant entry
(northwest corner of Corridor H501) to read “MP1”.
b. Reflected Ceiling Plan Legend: Revise the notation “MP2” at the ceiling type legend (lower
right of sheet) to read “MP1”.
5. DRAWING A3.2 – INTERIOR ELEVATIONS:
a. Elevation 3 / North Hallway – North Elevation:
- Removed incorrect door numbers that refer to former numbering at Building Shell.
b. Elevation 5 / East Hallway – East Elevation:
- Removed incorrect door numbers that refer to former numbering at Building Shell.
- Corrected door elevation at Door 501 into Quiet Room.
6. DRAWING A5.1 – DOOR SCHEDULE AND DETAILS:
a. Replace with the attached Drawing A5.1, which has been revised as follows:
1) Revised notes below Door Schedule to indicate that Doors, Frames and Hardware are
to be both Furnished and Installed by Contractor.
6,
ARTIFICIAL INTELLIGENCE LAB UPFIT ADDENDUM 03
University of South Carolina May 5, 2020
4
2) Door Schedule:
- Noted doors to receive knock-down frames.
- Noted doors which will have access control.
- Revised door 505 to be type P02.
- Revised door 528 to be type P05.
- Revised door 529A to be type P04.
3) Panel Type Elevations:
- Added Type P04 (wood/glass double door – similar to P03)
- Revised Type P05 from double to single panel.
D. QUESTIONS & CLARIFICATIONS:
1. Question: Please indicate a location for dumpster.
Answer: Space for dumpster will be provided at the south side of the building along Devine
Street.
2. Question: Is there a location for material storage?
Answer: In addition to Level 5 shell areas, the Contractor may store items at Level 1 of the
building (one floor above the Loading Dock area).
3. Question: Will parking be provided?
Answer: Parking is not provided for the project. Previous contractors at site have leased
parking spaces along Devine Street from the City of Columbia parking. For availability of USC
Parking for lease contact Allen Broadus at USC Parking Services, Email:
[email protected] Phone: (803) 777-4316.
4. Question: Will contractors be able to use an elevator?
Answer: Contractor may use existing elevator (+/- 63” x 84”). Elevator finishes must be
covered and protected by Contractor.
5. Question: What is anticipated start date for this project?
Answer: Notice to Proceed is expected to be issued in the 3rd or 4th week of June.
6. Question: Are Contractors allowed to utilize Restrooms at Level 5 for employee use?
Answer: Finished Restroom spaces at the floor under construction may be used by employee
forces. Contractor is responsible for keeping restrooms cleaned and returning to Owner at end
of the project in the same condition.
7. Question: Please indicate the thickness of the concrete at the roof deck where the skylight is
scheduled to go.
Answer: Existing concrete roof slab is +/- 6” thick.
8. Question: At door H501B that wall is currently just metal studs onsite. Based on the wall
legend that is an existing wall assembly. Please indicate if we are supposed to provide
insulation, sheetrock, and finishing of that wall.
6,
ARTIFICIAL INTELLIGENCE LAB UPFIT ADDENDUM 03
University of South Carolina May 5, 2020
5
Answer: Walls at Doors H501B and 500A were framed without gypsum wallboard to allow for
installation of welded frames. 5/8” gypsum wallboard to be provided at both sides of these
walls as added by this addendum at Drawing A1.1.
9. Question: P0-1 indicates for the tie in of the sanitary piping to be done on the 4th floor. What
is the room below this tie in location?
Answer: A Conference Room is located at Level 4 below this area. Existing floor and reflected
ceiling plans (Drawings A1.14A and A2.14A) from the Building Construction are included in this
addendum for information.
10. Question: Are there any subcontractors we are required to use?
Answer: Any roofing work to accommodate the skylight must be done by Aquaseal Roofing as
noted in the documents, due to the existing warranty. There are no other required
subcontractors.
11. Question: There is currently an office framed near the new director’s office 512 but it doesn’t
line up with the wall locations on the drawing. Please indicate if we are to demo those walls
that are existing.
Answer: This wall is to be removed. See previously issued Addendum 02.
12. Question: How do we send in bid bond and turn in bid form on a conference call?
Answer: As noted in the Bid Advertisement, hand deliver or mail Bid, with Bid Bond included,
to the address on the bid invitation (and noted below) before the listed bid opening time of
10:00 a.m. on May 14, 2020. Make sure the “Bid Enclosed H27-A408” note is on the outside of
the envelope. If bid is mailed, make sure bid is in a separate sealed envelope inside the mailed
package.
Kristen Moss (Bid Enclosed H27-Z408)
925 Gadsden Street
Columbia, SC 29208
13. Question: Reference Spec Section 10-2600. Corner guards/Door Protection are included in the
specifications; however, there are no corner guards shown in drawings. Please confirm if corner
guards/door protection is required. If required, please provide locations.
Answer: Corner Guards are required at all outside corners of the finished spaces. These has
been noted with “CG” at the revised Drawing A1.1 issued as part of this addendum.
14. Question: Reference Drawing F0.1. Please confirm the shell space to the south of the AI Lab is
to be included in the fire sprinkler design for the AI Renovation Lab?
Answer: The shell space to the south of the AI Lab is to be included in the fire sprinkler design
for the AI Renovation lab. The contractor must provide a compliant sprinkler design for the
entire floor. See Drawing F0-1 in the Construction Documents.
15. Question: Reference S0.1 and Spec 078100, please confirm the steel shown for the Add
Alternate 01- Skylight will require applied fireproofing.
Answer: Added steel will require fireproofing. See note added to Drawing S0.1 by this
addendum.
6,
ARTIFICIAL INTELLIGENCE LAB UPFIT ADDENDUM 03
University of South Carolina May 5, 2020
6
16. Question: Please Provide locations for the corner guards.
Answer: Corner Guards are required at all outside corners of the finished spaces. These has
been noted with “CG” at the revised Drawing A1.1 issued as part of this addendum.
17. Question: Is Old Castle storefront an acceptable alternate manufacturer for the storefront
system?
Answer: Old Castle has been added as an acceptable manufacturer per this addendum.
18. Question: There are LEED submittal requirements in certain spec sections. Please confirm this
isn’t a LEED job.
Answer: This project is not pursuing LEED certification, and there are no requirements for LEED
submittals.
19. Question: On A2.1, it calls out metal panels as MP-2. On the finish schedule A7.1, it
only list MP-1. Please clarify. Answer: The designation of “MP-2” has been revised to read “MP-1” per this addendum.
20. Question: On A7.1 it calls out a FWP-1 for fabric wall panels. The specification
section 097713 notes FWP-1, FWP-22 and FWP-3. Please clarify where & what size
these panels are to be located or installed. Answer: Only FWP-1 will be used. See Interior Elevations 4/A3.2, 5/A3.2 and 8/A3.2 for the
three locations where these panels are located, and sizes needed.
21. Question: Please clarify locations of any Corner Guards.
Answer: Corner Guards are required at all outside corners of the finished spaces. These has
been noted with “CG” at the revised Drawing A1.1 issued as part of this addendum.
22. Question: Please clarify locations for the window shades.
Answer: Window shades are shown at exterior windows of all finished rooms. Drawing A2.1
“West Tower – Level 5 – RCP”. See Reflected Ceiling Legend and “WS” noted at window
locations.
23. Question: Are existing walls at Corridor H501 to be finished?
Answer: Yes, Corridor H501 is a finished space. See Drawing A7.1 where paint, flooring and
other finishes are shown at all spaces to receive finishes as part of this work.
24. Question: Please indicate if the owner furnished door and hardware package
includes any glass or is the GC to provide all glass Answer: Per this addendum, the doors and hardware will be furnished by the General
Contractor. All glass is to be provided by GC.
25. Question: A5.1 indicates for door 529A to be type P06 but this doesn’t match the
SF1L elevation shown on A6.1. Please confirm 529A should be type P05. Answer: 529A shall be a double wood door with glass lites as shown at the Elevation on A6.1.
Door Type P04 (double door – matching single door P03) is added by this addendum.
6,
ARTIFICIAL INTELLIGENCE LAB UPFIT ADDENDUM 03
University of South Carolina May 5, 2020
7
26. Question: Door 501 on A5.1 indicates type P01 but wood and glass. Elevation on
A3.2 shows a solid door, please confirm there is no glass in this door
Answer: Door 501 is to be wood and glass door type P03. This change is made in this
addendum 03. Note the door numbers shown on interior elevations A3.2 were the former
door numbers and do not correlate with the door schedule. They are also removed by this
addendum.
27. Question: Door 505 on the door schedule is called out to be P04 but there is no P04
panel type elevation. Please provide an elevation for this door. Answer: Door 505 is to be panel type P02 (double solid flush door). This change has been
made by this addendum.
28. Question: A6.1 bottom right corner indicates double row glass film pattern for all GL-01
locations. Can you please clarify what this means? If a glass film is required at GL-01 please
provide a spec on the film.
Answer: All glass designated as GL-01 will have a double row of film “tick” marks as detailed to
help avoid persons walking into a clear pane of glass. See Section 08 8719- Decorative Window
Film, added to project manual by this addendum for the material.
29. Question: Section 230900 – Building Automation and Temperature Control System
Page 7 Section 1.9.A.4 – Please clarify the requirement for a 5 year warranty is desired.
Suggestion, USC standard warranty is one year.
Answer: Warranty period shall be one year from date of Substantial Completion
30. Question: Section 230900 – Building Automation and Temperature Control System
Page 21 Sect 3.4 – Is there training required specifically for this space, no amount of hours is
stipulated.
Answer: JCI shall provide owner field training during a customer turnover walk through.
31. Question: Section 230900 – Building Automation and Temperature Control System
Page 22, Commissioning, Testing, Acceptance – This is a very comprehensive and stringent
requirement for the VAV boxes. It will be expensive to cover this time consuming requirement.
Item F. Is it expected we provide the testing devices as indicated to be turned over to the
Owner. Suggestion JEC will typically perform point to point check out and functional test, and
submit report to the owner’s agent.
Answer: Commissioning and testing shall comply with specifications.
END OF ADDENDUM THREE
6,
DECORATIVE WINDOW FILM 08 8719 - 1
ARTIFICIAL INTELLIGENCE LAB RENOVATION
Level 5 – 1112 Greene Street
University of South Carolina
Project: H27-Z408
Addendum 03
05 May 2020
SECTION 08 8719 - DECORATIVE WINDOW FILM
PART 1 - GENERAL
RELATED DOCUMENTS
Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
SUMMARY
Section Includes:
1. Decorative Window Film.
PREINSTALLATION
MEETINGS
Preinstallation Conference: Conduct conference at Project site.
ACTION SUBMITTALS
Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations.
3. Installation methods.
Samples for Verification: For each finish product specified, two samples representing actual product, color, and patterns.
QUALITY ASSURANCE
Manufacturer Qualifications: All primary products specified in this section will be supplied by a single manufacturer with a minimum of ten (10) years experience.
Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.
Provide documentation that the installer is authorized by the Manufacturer to perform
Work specified in this section.
1. Provide a commercial building reference list of properties where the installer has
applied window film. This list will include the following information:
a. Name of building. b. The name and telephone number of a management contact.
06
PACKAGE 4: BUILDING CONSTRUCTION Classroom/Laboratory Redevelopment University of South Carolina
Project: H27-6118-FW-D Construction Documents
26 February 2018
DECORATIVE WINDOW FILM 08 8719 - 2
c. Type of glass.
d. Type of film. e. Amount of film installed. f. Date of completion.
2. Provide a Glass Stress Analysis of the existing glass and proposed glass/film
combination as recommended by the film manufacturer.
Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1. Finish areas designated by Architect. 2. Do not proceed with remaining work until workmanship, color, and sheen are
approved by Architect. 3. Refinish mock-up area as required to produce acceptable work.
CLOSEOUT SUBMITTALS
Maintenance Data: For window film to include in maintenance manuals
DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
Store and dispose of hazardous materials, and materials contaminated by hazardous materials, in accordance with requirements of local authorities having jurisdiction.
PROJECT CONDITIONS
Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
WARRANTY
At project closeout, provide to Owner or Owners Representative an executed current copy of the manufacturer’s standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.
PART 2 - PRODUCTS
MANUFACTURERS
Basis-of-Design Product: 3M Scotchcal, color “Frosted Crystal,” No. 7725-314.
DECORATIVE WINDOW FILM 08 8719 - 3
ARTIFICIAL INTELLIGENCE LAB RENOVATION
Level 5 – 1112 Greene Street
University of South Carolina
Project: H27-Z408
Addendum 03
05 May 2020
2.2 PERFORMANCE REQUIREMENTS
Fire Performance: Surface burning characteristics when tested in accordance ASTM E 84:
1. Flame Spread: 25, maximum. 2. Smoke Developed: 450, maximum
PART 3 - EXECUTION
EXAMINATION
Do not begin installation until substrates have been properly prepared.
If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
PREPARATION
Clean surfaces thoroughly prior to installation.
Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
INSTALLATION
Install in accordance with manufacturer's instructions.
Cut film edges neatly and square at a uniform distance of 1/8 inch (3 mm) to 1/16 inch (1.5 mm) of window sealant. Use new blade tips after 3 to 4 cuts.
Spray the slip solution, composed of one capful of baby shampoo or dishwashing liquid
to 1 gallon of water, on window glass and adhesive to facilitate proper positioning of film.
Apply film to glass and lightly spray film with slip solution.
Squeegee from top to bottom of window. Spray slip solution to film and squeegee a second time.
Bump film edge with lint-free towel wrapped around edge of a 5-way tool.
Upon completion of film application, allow 30 days for moisture from film installation to dry thoroughly, and to allow film to dry flat with no moisture dimples when viewed under normal viewing conditions.
PACKAGE 4: BUILDING CONSTRUCTION Classroom/Laboratory Redevelopment University of South Carolina
Project: H27-6118-FW-D Construction Documents
26 February 2018
DECORATIVE WINDOW FILM 08 8719 - 4
CLEANING AND PROTECTION
Remove left over material and debris from Work area. Use necessary means to protect film before, during, and after installation.
Touch-up, repair or replace damaged products before Substantial Completion.
After application of film, wash film using common window cleaning solutions, including ammonia solutions, 30 days after application. Do not use abrasive type cleaning agents and bristle brushes to avoid scratching film. Use synthetic sponges or soft cloths.
END OF SECTION 08 8719
EX-1 EX-2 EX-3 EX-4 EX-5 EX-6
EX-D
EX-E
EX-F
EX-G
EX-H
EX-B
EX-BB
EX-BC
EX-GH
EX-HH
A
B
C
D
E
F
EX-C
A3.1 1
4
2
3
A3.1 5
8
7
6
A3.1
9
12 10
11
A3.113 15
14
16
A3.1 17
A3.1
18
19
A3.22 1
A3.28
A3.2 56
7
A3.2
3
4
523
524
527
525
528
H501A
505
512
16' - 2 1/8" 9' - 8 3/4" 1' - 0"
V.I.F.
26' - 3 3/4"
CLEAR
6' - 0" 19' - 2 7/8" 22' - 8 3/8" 2' - 0" 11"
20' -
10
7/8"
14' -
10
1/2"
14' -
10
1/2"
26' -
6"
61' -
10
3/8"
CLE
AR
6' -
0"
10' -
1 5
/8"
V.I.
F.
11' -
8 3
/4"
11' -
10
3/4"
43' -
8 7
/8"
8' -
9"
ALI
GN
25' - 9" 9' - 7 7/8"
V.I.F.
15' - 1 1/8" 1' - 0" 1' - 0" 21' - 9" 3' - 0"
1' - 0"
7' - 11" 14' - 5 1/2" 2' - 11"16' - 7 5/8"
V.I.F.
8' - 7 7/8" 1' - 0"
14' -
1 1
/4"
11' -
9 1
/2"
12' -
10
1/2"
12' -
10
1/2"
12' -
10
1/2"
12' -
10
7/8"
4' -
7 1
/2"
CLE
AR
6' -
0"
6' -
5 7
/8"
11' -
10
1/2"
12' -
8 1
/8"
12' -
10
1/2"
12' -
10"
SF1G
SF1H
SF1F
SF1E
SF1K
SF1M
A6-aS 00 y
A3-aS 00
A3-aS 00
A3-aS 00
A3-aS 00
10' - 6 3/8"
CLEAR
6' - 0" ±87' - 10 5/8"
CLEAR
8' - 0"
3' - 0" EQ. EQ.
VIF
+/- 3' - 0"
11" VIF
11" VIF
1' - 0" 11" VIF
1' - 0" 1' - 0"
1' -
0"
1' -
0"
1' - 0" 1' - 0"EQ. EQ.
9' -
8"
1' - 6"
ALI
GN
2' - 0"
11"
4' - 8" 3' - 4"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
1' - 0"
1' - 0" 1' - 0"
11" VIF
1' - 0"
1' - 0" 1' - 6 3/4"1' - 0"
1' -
4"
1' -
0"
CLE
AR
3' -
9"
1' -
0"
1' -
0"
1' -
0"
1' -
0"
ALIGNALIGN
A6-aS 00
A6-aS 00 y
A6-aS 00 y
A6-aS 00
A6-aS 00
A6-aS 00
D3-aS 00 y
D3-aS 00
A6-aS 00 y
D3-aS 00 y
D6-aS 00 y
A3-aS 00 y
D3-bS 00
D3-bS 00
D3-aS 00
D3-bS 00 y
D3-bS 00 y
D3-bS 00 y
D6-aS 00
D3-a00
D3-a00
D3-a00
D3-a00
D3-a00
A6-aS 00
A6-aS 00
D6-aS 00
D3-b00
A6-b00
D3-a00
D3-a00
D3-a00
D3-a00
D3-a00
D3-a00
H504
500B 500A.2
500E
H501B
500A.1
500G
501
SF1P
A6-aS 00
D6-a00
A3-aS 00
A6-aS 00
A6-aS 00
D3-aS 00
A3-aS 00
A3-aS 00
A3-aS 00
A3-aS 00
D3-aS 00
D3-a00
D3-a00
D3-aS 00
D3-aS 00
D3-aS 00
D3-aS 00
D3-aS 00
D3-b00
D3-b00
D3-b00
D3-b00
D3-b00
D3-b00
D3-aS 00
D3-aS 00
D3-aS 00
D3-aS 00
D3-a00
D6-aS 00
D3-bS 00 y
D3-bS 00 y
D3-b00 y
A6-a00
D3-aS 00
D3-aS 00D3-aS 00
D3-aS 00
D3-aS 00
D3-aS 00
D3-aS 00D3-aS 00
D3-aS 00D3-aS 00
D3-aS 00 y
A6-aS 00 y
D3-b00 y
A6-aS 00
A6-aS 00
D3-b00
D3-b00
D3-b00
D3-b00
D3-b00
D3-bS 00 yD3-a
S 00 yD3-aS 00
D3-bS 00 y D3-b
S 00 y
D3-b00 y
D3-b00 y
A3-b00 y
A6-aS 00
A6-aS 00
D3-a00
D3-a00
D3-a00
D3-b00
D3-b00
D3-aS 00
D3-aS 00
D3-aS 00
D3-aS 00
D3-a00
D3-b00
D6-aS 00
A6-aS 00 A6-a
S 00
EXTERIOR EXTERIOR WALL ASSEMBLY EW-03:AIR BARRIER AND RIGID INSULATION HAS BEEN PROVIDED AT EXTERIOR WALLS. METAL STUD FRAMING & GWB TO BE ADDED AT UPFIT LOCATIONS AS SHOWN AT THIS SHEET,
ALI
GN
SF1N
SF1N
OFFICE517
OFFICE518
OFFICE519
OFFICE520
SHELL500
CORRIDORH505
SHELL500B
SHELL500E
SHELL500G
CORRIDOR
H501
QUIET ROOM501
SEMINAR529
AI LAB524
POST DOC526
INFORMALSTUDY
528
POST DOC527
CONFERENCE523
DIRECTOR512
INFORMALSTUDY
508
COFFEE/BREAK507
STORAGE505
STORAGE525
GLYCOL500A
OFFICE521
OFFICE514
WORKROOM522
INFORMALSTUDY
511
CORRIDORH502
WOMENS504
FAMILY RR503
JANITOR502
MENS500H
ELEC500D
DATA500F
STAIRST03
ROOF EQUIP.ACCESS
500C
STAIRST02
ELEC510
TEAM ROOM509
ELEC (ROOFTOP EQUIP.)
506
SF1L
SF1J
A6-aS 00 y
MTR
MTR
MTR
MB MBMB MB
MBMB
MB
MB
MB
509
521
520
519
518
529A
529B
CORRIDORH503
500A
CORRIDORH506
SF1D
SF1B
SF1A
SF1B
11" VIF
CLEAR
8' - 0"
CENTER WALL ON EXISTING MULLION
ALI
GN
EXTERIOR EXTERIOR WALL ASSEMBLY EW-03:AIR BARRIER AND RIGID INSULATION HAS BEEN PROVIDED AT EXTERIOR WALLS. METAL STUD FRAMING & GWB TO BE ADDED AT UPFIT LOCATIONS AS SHOWN AT THIS SHEET,
D6-aS 00
A6-aS 00
A3-b00 y
(ABOVE)D6-aS 00
(ABOVE)D6-aS 00
(ABOVE)D6-aS 00
OFFICE515
OFFICE516
513
514
515
ADMIN513
SF1C
SF1B
SF1A
516
517
SF1B
SF1A
D3-aS 00 y
ALI
GN
6"
A6-aS 00
A6-aS 00
D3-aS 00 y
A4.1
6
5
A4.1
526
MB MB
1. PROTECT EXISTING BUILDING FINISHES AND FIXTURES ALREADY IN PLACE.
2. DIMENSIONS ARE TO FINISHED FACE OF GYPSUM WALLBOARD OR CENTER OF WALL AS INDICATED
AT PLAN.
3. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR ALL WALL-MOUNTED CASEWORK, HANDRAILS,
EQUIPMENT, TOILET ACCESSORIES, MONITORS, MARKERBOARDS, ETC.
4. OWNER PROVIDED MATERIALS STORED ON FLOOR TO BE UTILIZED BY CONTRACTOR ON PROJECT:
- 650 PIECES 4' X 10' - 5/8" GYPSUM WALLBOARD
- 115 PIECES 4' X 12' - 5/8" GYPSUM WALLBOARD
- 1000 PIECES OF 3 5/8" X 15' STUDS
- 120 PIECES OF 3 5/8" REGULAR TRACK
- 96 PIECES OF 3 5/8" SLIP TRACK
5. OWNER FURNISHED/CONTRACTOR INSTALLED ITEMS:
- PROJECTION SCREEN AND PROJECTOR
GENERAL NOTES
MB
2 HR FIRE RATED WALL ASSEMBLY
1 HR FIRE RATED WALL ASSEMBLY
EXISTING WALL ASSEMBLY
MARKERBOARD (4'-0" WIDE X 7'-10" TALL - MOUNTED 4" A.F.F.)
LEGEND
Th
ese d
raw
ing
s a
re t
he p
rop
ert
y o
f W
ats
on T
ate
Savo
ry,
Inc.
and
may n
ot
be u
se
d in w
ho
le o
r in
part
with
ou
t w
ritt
en c
onsent
of
the a
rch
itects
and
any
infr
ing
em
en
t is
su
bje
ct
to leg
al actio
n.
Project Number:
Date:
Revisions:
NO. ISSUED FOR DATE
AR
TIFI
CIA
L IN
TELL
IGEN
CE
INTE
RIO
R U
PFI
T
Leve
l 5 -
1112
Gre
ene
Str
eet
H27-Z408
27 MARCH 2020
BIM
360
://U
SC
CT
L B
uild
ing
/US
C C
lassro
om
an
d L
ab
Ren
ova
tion
A18
.rvt
4/1
5/2
020
11:1
4:1
4 A
M A1.1
WEST TOWER
LEVEL 5 - FLOOR
PLAN
CO
LUM
BIA
, SC
UN
IVER
SIT
Y O
F S
OU
TH C
AR
OLI
NA
CONSTRUCTION DOCUMENTS
1/8" = 1'-0"A1.1
1 LEVEL 5 - WEST TOWER BUILDOUT - FLOOR PLAN N
4'0' 8' 16' 32'
CG
CG
CG
CG
CG CG
CG
CG
CG
CG
CG CG
CG
CG
CG
CG
CG
CG
CG
CG
CGCG CG
CG CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CGCG
CGCG
CGCGCG
CGCGCGCG
CG
CG
CG
CG
PROVIDE 5/8" GWB AT BOTHSIDES OF EXISTING 6" METALSTUD FRAMING AT SOUTHWALL OF GLYCOL ROOM 500A
PROVIDE 5/8" GWB AT BOTHSIDES OF EXISTING 6" METALSTUD FRAMING AT SOUTHWALL OF CORRIDOR H501
ADDENDUM 03 REVISIONS05.06.20
HALLWAY
CJ CJ
GL-01 GL-02 GL-02 GL-02 GL-02 GL-02 GL-02 GL-02 GL-02GL-02 GL-02 GL-02
PT-1
RB-2
GL-02
8' -
2"
CJ CJ
GL-02 GL-02 GL-02 GL-02 GL-02GL-02 GL-02 GL-02 GL-02 GL-02 GL-02GL-02 GL-02GL-02
RB-2
PT-1
GL-02
PT-1
PT-1
FEC
2
A4.2
GL-01 GL-01 GL-01 GL-01GL-01 GL-01
WD-1
PT-1PT-1 PT-2 PT-2
WD-1
PT-1
RECESSED WINDOW SHADE POCKET AT EXTERIOR CURTAINWALL
EXISTING FIRE EXTINGUISHER & CABINET
RB-2RB-2RB-2 RB-2 WD-1
4
A4.1PT-2
EXISTING EXTERIOR ALUM. STOREFRONT
EXISTING EXTERIOR ALUM. STOREFRONT
EXISTING DOORS & WALLS SHOWN UNSHADED (TYP.)
9
A4.1
3
A4.2
41
C6-aS 02
41
HALLWAY
HALLWAY
HALLWAYINFORMAL STUDY/PRESENTATION
2
A4.2
GL-01 GL-01 GL-01 GL-01 GL-01 GL-01 GL-01 GL-01 GL-01
WD-1
PT-1
7
A4.2
PT-1
FWP-1 FWP-1 FWP-1
EQ.10' - 6"EQ.
3' -
2"
5' -
0"
1' -
4"
RB-1 RB-2 RB-2 RB-2
7
A4.1 5
A4.23
A4.2
GL-03 GL-03
CJCJ CJCJ CJCJ CJCJ
WD-1WD-1
6
A4.2
PT-1PT-1 PT-1 PT-1
EXISTING FIRE EXTINGUISHER & CABINET
RB-1 RB-1
EXISTING DOORS & WALLS SHOWN UNSHADED (TYP.) EXISTING WATER COOLER EXISTING WATER COOLER
EXISTING ELEVATOR DOORS
EQ. EQ. RECYCLING/TRASH CABINET
FWP-1 FWP-1
5
A4.1
7
A4.1
1
A4.2
41
41 41 41 41 41 41
HALLWAY
CJ CJ
GL-01 GL-04
CJ CJ
GL-01 GL-01
WD-1 WD-1
4
A4.2
GL-04GL-04
RB-1RB-1RB-1
PT-1 PT-2PT-1PT-1
11' - 10" 19' - 11 3/8" 26' - 3 1/4"
GL-01
METAL PANEL TRIM (MP-1) AT SOFFIT & WALLS OF ENTRY
MP-1
HALLWAY
CJ CJ
PT-1
PT-1 PT-1
RB-1
HALLWAYGL-02 GL-02 GL-02 GL-02
CJ CJ
RB-1
PT-1
PT-1
RB-1
FWP-1 FWP-1 FWP-1
EQ. 3' - 6" 3' - 6" 3' - 6" EQ.
3' -
2"
5' -
0"
1' -
4"
7
A4.1
Th
ese d
raw
ing
s a
re t
he p
rop
ert
y o
f W
ats
on T
ate
Savo
ry,
Inc.
and
may n
ot
be u
se
d in w
ho
le o
r in
part
with
ou
t w
ritt
en c
onsent
of
the a
rch
itects
and
any
infr
ing
em
en
t is
su
bje
ct
to leg
al actio
n.
Project Number:
Date:
Revisions:
NO. ISSUED FOR DATE
AR
TIFI
CIA
L IN
TELL
IGEN
CE
INTE
RIO
R U
PFI
T
Leve
l 5 -
1112
Gre
ene
Str
eet
H27-Z408
27 MARCH 2020
BIM
360
://U
SC
CT
L B
uild
ing
/US
C C
lassro
om
an
d L
ab
Ren
ova
tion
A18
.rvt
5/6
/20
20 1
:27
:02
PM
A3.2
INTERIOR
ELEVATIONS
CO
LUM
BIA
, SC
UN
IVER
SIT
Y O
F S
OU
TH C
AR
OLI
NA
CONSTRUCTION DOCUMENTS
1/4" = 1'-0"A3.2
1 WEST HALLWAY - EAST ELEVATION1/4" = 1'-0"A3.2
2 WEST HALLWAY - WEST ELEVATION
1/4" = 1'-0"A3.2
3 NORTH HALLWAY - NORTH ELEVATION
1/4" = 1'-0"A3.2
4 NORTH HALLWAY - SOUTH ELEVATION
1/4" = 1'-0"A3.2
5 EAST HALLWAY - EAST ELEVATION
1/4" = 1'-0"A3.2
6 EAST HALLWAY - WEST ELEVATION
1/4" = 1'-0"A3.2
7 CENTRAL HALLWAY - EAST ELEVATION1/4" = 1'-0"A3.2
8 CENTRAL HALLWAY - WEST ELEVATION
41 Addendum 02 05/01/20202 Addendum 03 05.06.2020
2 2
2
2
22222
2"
1/2"
1/2"
SEE
PLA
N
SC
HED
PA
RTI
TIO
N
SEALANT, TYP. (BOTH SIDES)07 9200.C
SCHED HM FRAME08 1113.A3
SCHED HM DOOR08 1113.A2
5/8" GWB09 2900.A1
SCHED SOUND ATTEN BLANKET07 2100.B1
SCHED MTL STUD FRAMING09 2216.A0
SCHED SOUND ATTEN BLANKET07 2100.B1
HM FRAME ANCHOR08 1113.B1
GWB NOT INSTALLED AT ONE SIDE OF WALL AT SHELL SPACES - BUT FRAMES SIZED TO ACCOMODATE FUTURE GWB
GYPSUM WALLBOARD 1 SIDE ONLY AT JAMB J1A
2"
1/2" 1/2"
SEE PLAN
SCHED PARTITION
SEALANT, TYP. (BOTH SIDES)07 9200.C
SCHED HM FRAME08 1113.A3
SCHED HM DOOR08 1113.A2
5/8" GWB09 2900.A1
SCHED SOUND ATTEN BLANKET07 2100.B1
SCHED MTL STUD FRAMING09 2216.A0
SCHED SOUND ATTEN BLANKET07 2100.B1
SCHED MTL STUD BOX HEADER09 2216.A13
GWB NOT INSTALLED AT ONE SIDE OF WALL AT SHELL SPACES - BUT FRAMES SIZED TO ACCOMODATE FUTURE GWB
GYPSUM WALLBOARD 1 SIDE ONLY AT JAMB J1A
ABBREVIATIONS:
ALUM ALUMINUM
ANOD ANODIZED
EXT SF EXTERIOR STOREFRONT
GL GLASS
HM HOLLOW METAL
INT SF INTERIOR STOREFRONT
PREFIN PREFINISHED
PT PAINT
ST STAIN
WD WOOD
DOOR & FRAME TYPE LEGEND:
AL ALUMINUMGL GLASSHM HOLLOW METALST STEELWD WOOD
MATERIAL
PANELS:
P01.WD
TYPE NUMBERSEE DOOR SCHEDULE & DOOR/FRAME ELEVATIONS
AL ALUMINUMCW INTEGRATED INTO CURTAIN WALL SYSTEMHM HOLLOW METALST STEELWD WOOD
MATERIAL
FRAMES:
F02.HM
TYPE NUMBERSEE DOOR SCHEDULE & DOOR/FRAME ELEVATIONS
X
Y
X= 18" MIN. (24" PREFERRED)Y= 60" MIN.
PULL SIDE
FRONT APPROACH
Y
X= 12" IF DOOR HAS BOTH CLOSER & LATCHY= 48" MIN.
PUSH SIDE
X
NOTES:
ERECT ALL DOOR FRAMES & ADJACENT WALLS TO CONFORM TO THE APPLICABLE PLAN CONFIGURATION. NOTIFY ARCHITECT OF AN CONFLICTS PRIOR TO INSTALLATION.
ALL DOORS SHALL COMPLY WITH THE CLEARANCES FOR APPROACHES INDICATED.
X
Y
X= 36" MIN. (IF Y= 60")X= 42" MIN. (IF Y= 54")
PULL SIDE
HINGE SIDE APPROACH
Y
X= 12" IF DOOR HAS BOTH CLOSER & LATCHY= 48" MIN.
PUSH SIDE
X
DOOR CONFIGURATION PLANS:
X
Y
X= 24" MIN.Y= 48" MIN. (54" MIN. IF DOOR HAS CLOSER)
PULL SIDE
LATCH SIDE APPROACH
Y
X= 24" MIN.Y= 42" MIN.
PUSH SIDE
X
SCHED HM DOOR FRAME, BEYOND
SCHED DOOR
CONCRETE SLAB, SEE STRUCTURAL
SCHED RESILIENT FLOORING SYSTEM/BBT/EPOXY
SCHED CARPET OR CARPET TILE
METAL EDGE STRIP
SCHED HM DOOR FRAME, BEYOND
SCHED DOOR
CONCRETE SLAB, SEE STRUCTURAL
SCHED CARPET OR CARPET TILE
TRANSITION CARPET TYPE AT CENTERLINE OF DOOR
SCHED HM DOOR FRAME, BEYOND
SCHED DOOR
CONCRETE SLAB, SEE STRUCTURAL
SCHED RESILIENT FLOORING SYSTEM
SCHED CONCRETE OR SIMILAR
METAL EDGE STRIP
SCHED HM DOOR FRAME, BEYOND
SCHED DOOR
CONCRETE SLAB, SEE STRUCTURAL
SCHED CARPET OR CARPET TILE
METAL EDGE STRIP
SCHED CONCRETE OR SIMILAR
P01 P06
PANEL TYPE ELEVATIONS:
P02 P05
SC
HE
D. H
EIG
HT
WIDTH
SCHED.
5"10
"
WIDTH
SCHED.
SC
HED
. HEI
GH
T
4" 8"
2' -
0"
3' -
10"SC
HED
. HEI
GH
T
WIDTH
SCHED.
WIDTH
SCHED.
SC
HED
. HEI
GH
T
FLUSH PANEL
SCHED. MATERIAL & FINISH
SCHED. MATERIAL & FINISH
SCHED. MATERIAL & FINISH ALUMINUM
STOREFRONT DOOR
P03
8" 1' - 8" 8"
8"1'
- 8
"
SC
HED
. HEI
GH
T
WIDTH
SCHED.SCHED. MATERIAL & FINISH
GLASS TYPE GL-05
GLASS TYPE GL-05
5"5"
GLASS TYPE GL-05
P04
8" 1' - 8" 8"
8"1'
- 8
"
SC
HED
. HEI
GH
T
WIDTH
SCHED.
SCHED. MATERIAL & FINISH
GLASS TYPE GL-05
8" 1' - 8" 8"
41
F01
2"
WIDTH
SCHED. 2"
FRAME TYPE ELEVATIONS:
2"
SC
HE
D. H
EIG
HT
HOLLOW METAL
F02
ALUMINUM
2"
WIDTH
SCHED. 2"
2"S
CH
ED. H
EIG
HT
F03
DOUBLE EGRESS
2"
WIDTH
SCHED. 2"
2 5/
8"S
CH
ED. H
EIG
HT
GLAZING SCHEDULE:
GL-01: 1/2" CLEAR INTERIOR GLAZING / FULLY TEMPERED (Interior Storefront Clear)
GL-04: 1/2" ETCHED GLAZING / FULLY TEMPERED (Main Entry at Suite)
GL-02: 1/2" LAMINATED / FULLY TEMPERED (Interior Storefront with Opaque Strip from 2'-8" to 5'-4" a.f.f.)
GL-03: 1/2" LAMINATED TRANSLUCENT / FULLY TEMPERED (Interior Storefront Translucent)
GL-05: 1/4" CLEAR INTERIOR / FULLY TEMPERED (Non-Rated Doors)
SEE PLAN
SCHED PARTITION
SEALANT, TYP. (BOTH SIDES)07 9200.C
ALUM STOREFRONT HEAD08 4113.E
5/8" GWB09 2900.A1
SCHED SOUND ATTEN BLANKET07 2100.B1
SCHED MTL STUD FRAMING09 2216.A0
SCHED MTL STUD BOX HEADER09 2216.A13
FRAME FLUSH WITH FACE OF GWB AT CORRIDOR SIDE
SCHEDULED DOOR
SEE
PLA
N
SC
HED
PA
RTI
TIO
N
SEALANT, TYP. (BOTH SIDES)07 9200.C
ALUM STOREFRONT JAMB08 4113.B
5/8" GWB09 2900.A1
SCHED SOUND ATTEN BLANKET07 2100.B1
SCHED MTL STUD FRAMING09 2216.A0
FRAME FLUSH WITH FACE OF GWB AT CORRIDOR SIDE
SCHEDULED DOOR
Th
ese d
raw
ing
s a
re t
he p
rop
ert
y o
f W
ats
on T
ate
Savo
ry,
Inc.
and
may n
ot
be u
se
d in w
ho
le o
r in
part
with
ou
t w
ritt
en c
onsent
of
the a
rch
itects
and
any
infr
ing
em
en
t is
su
bje
ct
to leg
al actio
n.
Project Number:
Date:
Revisions:
NO. ISSUED FOR DATE
AR
TIFI
CIA
L IN
TELL
IGEN
CE
INTE
RIO
R U
PFI
T
Leve
l 5 -
1112
Gre
ene
Str
eet
H27-Z408
27 MARCH 2020
BIM
360
://U
SC
CT
L B
uild
ing
/US
C C
lassro
om
an
d L
ab
Ren
ova
tion
A18
.rvt
5/6
/20
20 1
:27
:05
PM
A5.1
DOOR SCHEDULEAND DETAILS
CO
LUM
BIA
, SC
UN
IVER
SIT
Y O
F S
OU
TH C
AR
OLI
NA
CONSTRUCTION DOCUMENTS
DOOR SCHEDULE - LEVEL 5
MARK
DIMENSIONS
RATING
PANEL FRAME DETAILS HDWR
SET REMARKSWIDTH HEIGHT THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL
Level 5 Upfit
500A 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD PAINT F01 HM PAINT H1A J1A --- INT-04
500A.1 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD PAINT F01 HM PAINT H1A J1A --- INT-04 KNOCK-DOWN FRAME
500A.2 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD PAINT F01 HM PAINT H1A J1A --- INT-04 KNOCK-DOWN FRAME
500B 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD PAINT F01 HM PAINT H1A J1A --- INT-04 KNOCK-DOWN FRAME
500E 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD PAINT F01 HM PAINT H1A J1A --- INT-04 KNOCK-DOWN FRAME
500G 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD PAINT F01 HM PAINT H1A J1A --- INT-04 KNOCK-DOWN FRAME
501 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
505 6' - 0" 8' - 0" 0' - 1 3/4" -- P02 WD STAIN F01 HM PAINT H1 J1 --- INT-07
509 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S3 INT-06
512 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 --- INT-05
513 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
514 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
515 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
516 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
517 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
518 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
519 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
520 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
521 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 --- INT-05
523 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S3 INT-06
524 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-06
525 3' - 0" 7' - 0" 0' - 1 3/4" -- P01 WD STAIN F01 HM PAINT H1 J1 --- INT-08
526 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL ST F02 ALUM PREFIN H2 J2 S4 INT-04
527 3' - 0" 8' - 0" 0' - 1 3/4" -- P03 WD/GL STAIN F02 ALUM PREFIN H2 J2 S4 INT-05
528 3' - 0" 8' - 0" 0' - 1 3/4" -- P05 ALUM/GL PREFIN F02 ALUM PREFIN -- -- S4 INT-09 CARD READER
529A 6' - 0" 8' - 0" 0' - 1 3/4" -- P04 WD/GL STAIN EXT. STF. ALUM PREFIN H2 J2 S3 INT-10
529B 3' - 0" 8' - 0" 0' - 1 3/4" -- P06 WD STAIN F01 HM PAINT H1 J1 S4 INT-11
H501A 6' - 0" 8' - 0" 0' - 1 3/4" -- P02 WD STAIN F03 HM PAINT H1 SIM. J1 SIM. --- INT-01
H501B 6' - 0" 8' - 0" 0' - 1 3/4" -- P02 WD STAIN F03 HM PAINT H1 SIM. J1 SIM. S2 INT-02
H504 3' - 0" 8' - 0" 0' - 1 3/4" -- P01 WD STAIN F01 HM PAINT H1 J1 S1 INT-03
3" = 1'-0"A5.1
J1 JAMB DETAIL
3" = 1'-0"A5.1
H1 HEAD DETAIL
6" = 1'-0"A5.1
S4 CARPET TILE TO RESILIENT FLOOR6" = 1'-0"A5.1
S3 CARPET TILE TO CARPET TILE6" = 1'-0"A5.1
S2 RESILIENT FLOOR TO CONCRETE6" = 1'-0"A5.1
1 CARPET TILE TO CONCRETE FLOOR
3" = 1'-0"A5.1
H2 HEAD DETAIL
3" = 1'-0"A5.1
J2 JAMB DETAIL
41 Addendum 02 05/01/2020
DOORS, HOLLOW METAL FRAMES & DOOR HARDWARE - CONTRACTOR PROVIDED AND INSTALLED:
- HOLLOW METAL FRAMES (PER SECTION 08 1113 "HOLLOW METAL DOORS AND FRAMES" AND DOOR SCHEDULE AT DWG. A5.1)
- WOOD DOORS (PER SECTION 08 1416 "FLUSH DOORS" AND DOOR SCHEDULE AT DWG. A5.1)
- DOOR HARDWARE PER SECTION 08 7100 "DOOR HARDWARE"
NOTE THAT ALUMINUM DOORS AND FRAMES TO BE PROVIDED BY CONTRACTOR PER SECTION 08 4113.
41
41
41
41
2 Addendum 03 05.06.2020
2
2
2
2
2
UPUP
UPUP
SS
S
S
S
H
H
H
H
ARC
PP
PP
H
H
PP
PP
FS
TS
FS
TS
ARC
ARC
ARC
ARC
S
S
EX-1 EX-2 EX-3 EX-4 EX-5 EX-6
EX-8 EX-9
EX-D
EX-E
EX-F
EX-G
EX-H
EX-B
1
A3.21
A
A3.20
EX-BB
EX-BC
EX-GH
EX-HH
A
B
C
D
E
1 2
F
EX-C
A3.10
1
ORGANICCHEMISTRYTEACHING
LAB411
VESTIBULE411B
HONORS/MAJORSORGANIC
CHEMISTRYTEACHING
LAB414
SUPPORTLAB415
ORGANICCHEMISTRYTEACHING
LAB
416
VESTIBULE416B
ELEV. 2EV02
MENS427
STAIRST02
INFORMALSTUDY
410
TEAMMEETING
407
INFORMALSTUDY
406
CONFERENCE
405
STAIRST03
SENIORORGANIC
INSTRUCTOROFFICE
421
INFORMALSTUDY
423
INFORMALSTUDY
419
VESTIBULE414B
INFORMALSTUDY
401
ELEC408
ELEC420
CLASSROOM417
ORGANICCHEMISTRYTEACHING
LAB418
VESTIBULE418B
SS-1
ESE-1
SS-1 SS-1
ESE-1
SS-1
ESE-1
WOMENS404
JANITOR402
FAMILY RR403
ORGANICLAB
MANAGEROFFICE
424
ORGANICINSTRUCTOR
OFFICE425
CU
BB
IES
1
A4.10
2
A4.10
3
A4.10
1
A4.11
TELECOM422
ELEV. 1EV01
CORRIDORH401
402
404
H401A
408S402
413
B412B
411B414B
418B 416B
417C 417D
415
42
2
420S403
A6.31
3
A8.23
1
A8.23 23
A8.23
4
A8.22
1
A8.22
5
/1
A1
.14B
EX-7
NOTE: INTUMESCENT PAINT ON ALL EXPOSED STEEL COLS. AND FRAMING, TYP. SFRM ON ALL CONCEALED STEEL COLS. AND FRAMING, TYP.
OPEN TO BELOW
405
416A
2
A4.11
CLASSROOM412
CLASSROOM413
S406
C6-aS 02D3-b
00
D3-b00
D3-b00
C6-aS 02
C6-aS 02
D3-b00
A6-aS 00
A6-b00
D6-b00
A6-aS 00
A6-b00
D3-b00
D3-b00
D3-b00
A6-b00A6-a
S 00 D3-b00
A6-aS 00
D3-b00 y D3-
00
A6-aS 01
A6-aS 00
A6-aS 00
D3-b00
A6-b00
H6-aS 02
H6-aS 02
H6-aS 02
A6-b00
A6-b00
D3-b00
A6-aS 00
A6-aS 00
A6-aS 00
A6-aS 00
A6-aS 00
A6-aS 00
A6-aS 00
A6-aS 00
D3-b00
C6-aS 00
C6-aS 00
D3-b00
D3-b00
D6-b00
D3-b00
C6-aS 02
D3-b00
D3-b00
C6-aS 02
A6-b00
D3-b00
A6-b00
A6-b00
C6-aS 00
C6-aS 00
C6-aS 00
C6-aS 00
D3-b00
C6-aS 00
D3-b00
D3-b00
D6-b00
A6-aS 00
A6-aS 00
D3-b00
D3-00
D3-b00
D3-b00
D6-b00
C6-aS 00
C6-aS 02
D3-b00
D3-b00
D6-b00 D3-b
00
D3-b00
D3-b00
D3-b00
D3-b00
A6-b00
A6-aS 00
D3-b00
D3-b00
D6-b00
A6-b00
A6-b00
D3-b00
A6-b00
D3-b00
D6-b00
D3-b00
D3-b00
C6-aS 00
D3-b00
XEJC-01
XEJC-01
XEJC-01
XEJC-01
EJC-01
EJC-01
EJC-01EJC-01
D6-aS 00
D6-aS 00
C6-aS 02
C6-aS 02
C6-aS 02
H6-aS 02
H6-a02H6-a
S 02
H6-aS 02
A6-aS 00
A6-aS 00
A6-aS 00
C6-aS 00
C6-aS 00
C6-aS 00
C6-a02
C6-a02
C6-a02
H6-aS 02
H6-aS 02
D3-b00
A6-a01
C6-aS 00
A6-aS 00
A3.102
A6.10
4
A6.11
5
A6.20
5
A3.151
EW-03
D3-b00 y
D3-b00 y
H4-a02
H4-a01
D3-b00 y
OPEN TO BELOW
2 HR FIRE RATED MOTORIZED SHUTTER RECESSED IN CEILING
400A
4
A4.15
ORGANIC TAOFFICE
426
A10.41A E3
424
425
A10.42
2
A10.42
3
A10.42
6
417B
414A
426
A3.12 1
418A 417A
411A 412A
A6.31
5
SF103
SF103
SF103
SF102
SF1
13
SF101
SF114SF115
SF115 SF114 SF114 SF115
SF115SF114
413A
SF116
SF116SF116
SF116
SF120
SF120
SF1
21B
A6-aS 00
A6-aS 00
C6-aS 02
C6-aS 02
C6-aS 02
C6-aS 02
SIM.
SIM.D3-b00
D3-b00
4 3/4" 24' - 11 3/4" 3' - 0" 22' - 9" 6 3/4" 1' - 3 1/4" 20' - 0"
2' - 0 1/2"
3' - 8 1/2" 22' - 8 1/8"
2' - 7 1/4"
8' - 5 3/4" 2' - 10 7/8" 13' - 4 3/4" 1' - 0 7/8"
4 3/4"
24' - 11 3/4" 3' - 0"
11 1/4"
3' - 4" 4' - 4" 14' - 2 3/4"
1' - 9"
13' - 5 1/4" 5' - 0 1/2" 3' - 4"
2 3/4"
3' - 8 1/2" 25' - 3 3/8" 8' - 5 3/4" 8' - 2 1/8"
11 1/8" 3' - 8 1/8"
3' - 6 1/8"
1' - 0 7/8"
C6-aS 00
C6-aS 02
4 3/4"
24' - 11 3/4"
1' - 10"
20' - 9"
8' - 2"
20' - 9"
1' - 10"
20' - 10 3/4"
4' - 7 3/8"
1' - 2 3/4" 24' - 9" 3' - 4"1' - 9 3/4" 2"
5' - 7 3/8" 14' - 9 3/8" 15' - 2 1/4" 5' - 11"2"
1' - 9 3/4"
3' - 4" 24' - 9" 1' - 8 7/8" 7' - 10 1/2" 17' - 4 1/2"
A6-aS 00
D3-b00
4
A4.11
2
A4.15
1
A4.16
2
A4.16
1
A4.15
3
A4.16
4
A4.16
1
A4.13
A6.34B
7
8
EX-6CEX-6B
EW-05
EW-05
EW-05
EW-05
A3.10A
1
EW-03
EW-03EW-03EW-03
EW-03
EW-03
EW-03
EW-03
EW-03
EW-03EW-03
EW-03
EW-03
3
A4.15
4'x8' LOUVER SET IN EXISTING STOREFRONT FRAME. BOTTOM OF LOUVER 6" ABOVE SLAB.
A5.12 4 A5.105
A5.10
2
A5.10
3
A5.12 6
A5.11
13
A5.11
14
D3-00
C6-aS 00
D3-b00
D3-b00
C6-aS 02
C6-aS 02
D6-aS 00
D6-aS 00
D6-aS 00
A6-b00
A6-a00
A6-a00
D3-b00
H6-aS 02
H4-aS 02
A6-aS 00
D6-b00
HVAC EQUIPMENT, SEE MECHANICAL DRAWINGS
403
H4-a02
H4-a02
H4-a02
A6.37
5
A1.17A
2
A5.12
8
A5.12 9
1
A4.14
9
A6.35
24
A7.23
10
A5.12
10
O.H.
O.H.
O.H.
O.H.
O.H.
4
A5.12
14
421
407
CORRIDORH403
CORRIDORH402
O.H.
DECORATIVE METAL RAILING
6
9
A6.35SIM.
TV
TV
TV
6
6
SIM6
SIM
6
A8.243
1
A6.33
8
8
SF121A
SF1
19
SF121A
MB48.92
MB48.92
MB48.92
MB 4892
MB 4892
MB 4892
MB 4892MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MBP-4848
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
MB 4892
EX-6D
9' -
9 3
/8"
6' -
5 1
/2"
8' -
8 7
/8"
11"
11"
23' -
11"
11"
1' -
2"
15' -
1"
3' -
8 1
/2"
11' -
7"
3' -
8 1
/2"
15' -
1 3
/8"
1' -
1 5
/8"
10 1
/8"
24' -
2 7
/8"
8"11"
5' -
1 5
/8"
3' -
7 1
/4"
6' -
5 1
/2"
9' -
9 3
/8"
12
9' -
9 3
/8"
9' -
5 1
/2"
5' -
8 7
/8"
11"
11"
23' -
11"
3' -
7 1
/4"
46' -
1 1
/2"
3' -
7 1
/4"
31' -
5 7
/8"
9' -
5 1
/2"
9' -
9 3
/8"
12
1' - 5 3/8" 11"
16' -
2 7
/8"
8' -
8 7
/8"
11"
11"
24' -
0"
10"
1' -
1 3
/4"
15' -
1 1
/4"
3' -
8 1
/2"
11' -
7"
3' -
8 1
/2"
15' -
1 1
/4"
1' -
1 3
/4"
11"
24' -
0 1
/2"
9 1/
2"11
"5'
- 1
5/8
"3'
- 7
1/4
"6'
- 5
1/2
"9'
- 9
3/8
"
12
1' -
0 1
/4"
15' -
2 5
/8"
3' -
7 1
/4"
5' -
1 5
/8"
4' -
5"
4' -
7 1
/4"
16' -
8 3
/4"
3' -
8"
4' -
7 1
/4"
8' -
3"
8' -
3 3
/4"
2' -
8"
8' -
3 1
/2"
9' -
3 1
/4"
4' -
7 1
/4"
3' -
8"
16' -
8 3
/4"
4' -
7 1
/4"
4' -
5"
5' -
1 5
/8"
3' -
7 1
/4"
15' -
2"
1' -
0 7
/8"
3' -
7 1
/4"
3' -
6 3
/4"
1' -
0 7
/8"
11"
11"
3' -
10
3/8"
3' -
10
3/8"
TYP. AT COLUMNS,THIS ELEVATION
12
12
12
7' -
9 7
/8"
8' -
7"
8' -
8 3
/4"
1' -
0 7
/8"
1212
1' -
3 1
/2"
5' -
8 1
/2"
17' -
6"
12
1' -
0 7
/8"
11' -
8 1
/2"
12
7' - 10 7/16"
6' -
5 1
/2"
A3.10C
1
A3.10B
1
2
A6.33
1' -
10"
CENTER MARKERBOARDS ON WALL, TYP.
MB48.92 MB48.92
MB48.92 MB48.92
20
20
20
10' -
9 1
/4"
MB
.W.2
4.40
.24
6'-0" WIDE BY 14" DEEP X 24" TALL MAILBOX UNIT BY LAB CASEWORK CONTRACTOR, MOUNTED AT 3'-6" ABOVE FINISH FLOOR (PREVIOUSLY SHOWN AT SOUTH WALL OF SUPPORT LAB 415)
23
23
23
1' - 0 1/8"
TV LOCATION OF TELEVISION MONITOR TO BE PROVIDED AND INSTALLED BY OWNER. PROVIDE BLOCKING AT INTERIOR FRAMING. SIZE AND LOCATION TO BE PER THE A/V DRAWINGS ISSUED BY USC.
Th
ese d
raw
ing
s a
re t
he p
rop
ert
y o
f W
ats
on T
ate
Savo
ry,
Inc.
and
may n
ot
be u
se
d in w
ho
le o
r in
part
with
ou
t w
ritt
en c
onsent
of
the a
rch
itects
and
any
infr
ing
em
en
t is
su
bje
ct
to leg
al actio
n.
Project Number:
Date:
Revisions:
NO. ISSUED FOR DATE
CLA
SS
RO
OM
/LA
BO
RA
TOR
Y R
EDEV
ELO
PM
ENT
PA
CK
AG
E 4:
BU
ILD
ING
CO
NS
TRU
CTI
ON
H27-6118-FW-D
30 APRIL 2018
BIM
360
://U
SC
CT
L B
uild
ing
/US
C C
lassro
om
an
d L
ab
Ren
ova
tion
A18
.rvt
5/5
/20
20 6
:22
:18
PM
A1.14A
WEST TOWER -
LEVEL 4 - AREA
PLAN
CO
LUM
BIA
, SC
UN
IVER
SIT
Y O
F S
OU
TH C
AR
OLI
NA
CONSTRUCTION DOCUMENTS
1/8" = 1'-0"A1.14A
1 LEVEL 4 - AREA PLAN - WEST TOWERN
4'0' 8' 16' 32'
4
4
6
6
6
8
8
8
8
86
8
8
8
20
4 Addendum 02 02/01/18
6 OSE/Coordination 02/26/18
8 Conformed Set 04/30/18
12 Const. Bulletin 4.04 07/13/18
20 Const. Bulletin 4.15 02/06/19
23 Const. Bulletin 4.18 03/08/19
FOR INFORMATION ONLYADDENDUM 03 - 05.06.20
PDPC
WN
PDPC
WN
PDPC
WN
PDPC
WN
PP
PP
PDN
PCWV
PD
PCWN
P PCW
P D CW
N
P DC
W N
P D CW
N
P DC
W N
P D CW
N
P DC
W N
P D CW
N
P DC
W N
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PDCWN
PD
PCWN
PD
PCWN
PD
PCWN
PP
PP
PD
PCWN
PP
PP
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PP
PP
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
P DP
CW N
P DP
CW N
P DP
CW N
P DP
CW N
PD
PCWN
PD
PCWN
PD
PCWN
PD
PCWN
PDPC
WN
PDPC
WN
PDPC
WN
PDPC
WN
OS OS
OS OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OS
S
S
S S
S S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S SSF F
S
S
SS SF F
S
F
F
F
F
P P
EP
EP
S
SPP
SS
S
S
SS
P
P P
S S
S
J
J J
SC
SCS
S
S
EX-1 EX-2 EX-3 EX-4 EX-5 EX-6
EX-8 EX-9
EX-D
EX-E
EX-F
EX-G
EX-H
EX-B
EX-BB
EX-BC
EX-GH
EX-HH
A
B
C
D
E
1 2
F
EX-C
GYP-18' - 2"
GYP-18' - 2"
GYP-18' - 2"
GYP-18' - 2"
GYP-110' - 0"
ACP-X9' - 0"
ACP-110' - 0"
ACP-X10' - 0"
ACP-X10' - 0"
6' -
0"
ACP-X10' - 0"
ACP-19' - 6"
ACP-19' - 6"
ALIGN-TYP
EX-7
ACP-X10' - 0"
ACP-X10' - 6"
ACP-X10' - 0"
ACP-X10' - 0"
ACP-X10' - 0"
ACP-X10' - 0"
ACP-X10' - 0"
ACP-X10' - 0"
ACP-19' - 6"
ACP-19' - 6"
ACP-19' - 6"
ACP-X10' - 0"
GYP-110' - 0"
GYP-110' - 0"
GYP-110' - 0"
9' - 0"
9' - 0"
STAIRST06
ORGANICCHEMISTRYTEACHING
LAB411
CLASSROOM412
VESTIBULE411B
HONORS/MAJORSORGANIC
CHEMISTRYTEACHING
LAB414
SUPPORTLAB
415
ORGANICCHEMISTRYTEACHING
LAB416
CLASSROOM417
VESTIBULE416B
ORGANICCHEMISTRYTEACHING
LAB418
ELEV. 2EV02
MENS427
STAIRST02
INFORMALSTUDY
410
INFORMALSTUDY
406TEAMMEETING
407
CONFERENCE405
STAIRST03
INFORMALSTUDY
419INFORMAL
STUDY423
SENIORORGANIC
INSTRUCTOROFFICE
421
VESTIBULE414B
INFORMALSTUDY
401
ELEC
408
ELEC420
VESTIBULE418B
EM. GEN.EXHAUST
-
WOMENS404
SUPPLY-
ORGANICLAB
MANAGEROFFICE
424
ORGANICINSTRUCTOR
OFFICE
425
TELECOM422
ELEV. 1EV01
CORRIDORH401
CORRIDORH403
CORRIDORH402
CORRIDORH405
ORGANIC TAOFFICE
426
EJC-11
EJC-11
EJC-11
8
A2.20
2 HR FIRE RATED MOTOIZED SHUTTER RECESSED IN CEILING
SEE SHEET ATRIUM PLAN SHEET A6.30
1
A2.21
EQ 11 FULL TILES EQ
EQ21
FU
LL T
ILES
EQ
GYP-110' - 0"
EQ 10 FULL TILES EQ
EQ14
FU
LL T
ILES
EQ
EQ 10 FULL TILES EQ
EQ9
FULL
TIL
ESEQ
EQ2 FULL TILESEQ
EQ22
FU
LL T
ILES
EQ
EQ 49 FULL TILESEQ
ACP-X10' - 0"
CLASSROOM413
2
A2.21
EQ9
FULL
TIL
ESEQEQ 2 FULL TILES EQ
ACP-X10' - 0"
EQ14
FU
LL T
ILES
EQ
EQ 22 FULL TILES EQ
EQ21
FU
LL T
ILES
EQ
EQ 11 FULL TILES EQ
EQ 7 FULL TILES EQ
EQ3
FULL
TIL
ESEQ
EQ 6 FULL TILES EQ
EQ3
FULL
TIL
ESEQ
EQ 7 FULL TILES EQ
EQ7
FULL
TIL
ESEQ
EQ 7 FULL TILES EQ
EQ3
FULL
TIL
ESEQ EQ EQ
9' -
2 1
/8"
EQ5'
- 0
"EQ
EQ 7' - 0" 7' - 0" EQ
EQ5'
- 0
"EQ
EQ 8' - 0" 8' - 0" EQ
EQ 7' - 6" 7' - 6" EQ
EQ5'
- 0
"EQ
EQ 7' - 6" 7' - 6" EQ
EQ5'
- 0
"EQ
GYP-110' - 6"
GYP-110' - 6"
GYP-110' - 6"
GYP-110' - 0"
GYP-110' - 6"
GYP-110' - 6"
GYP-110' - 6"
EQ EQ
EQEQ
EQ EQ
EQEQ
EQ EQ
EQEQ
EQ EQ
EQEQ
EX-6CEX-6B
MANUAL WINDOW SHADE, RECESS MOUNT12 2413.B
MANUAL WINDOW SHADE, RECESS MOUNT12 2413.B
A4.51
4
A6.30A
2
9
A6.35
8
A0.03
8
A0.03
SIM.
7
A2.21SIM.
7
A2.21SIM.
5
A2.20
SIM.
8
A2.21
SIM.
3
A2.21
SIM.
1
A2.21
SIM.
6
A0.03
6
A0.03
SIM. O.H.9
A6.35 SIM
6
PROVIDE AT ALL EXTERIOR OPENINGS (WINDOW, CURTAINWALL, AND STOREFRONT) AT THE WEST TOWER, EXCLUDING LEVELS 1 AND 5 SHELL SPACES.
PROVIDE AT ALL EXTERIOR OPENINGS (WINDOW, CURTAINWALL, AND STOREFRONT) AT THE WEST TOWER, EXCLUDING LEVELS 1 AND 5 SHELL SPACES.
6
6
8
8
8
EX-6D
GYP-110' - 0"
8' -
8 7
/8" 16
' - 8
3/4
"16
' - 8
3/4
"
8' -
9"
18
18
18
18
18
18
PT-1 GYP CEILING,EGGSHELL FINISH
PT-13 GYP CEILING
PT7 GYP CEILING,EGGSHELL FINISH
PT-13 GYP CEILINGPT-1 GYP CEILING,EGGSHELL FINISH
PT-1 GYP SOFFIT
PT-1 GYP CEILING
PT-1 GYP CEILING
PT-13 GYP AT ROOF VENT OPENINGS, TYP.
PT-3 AT GYP. CEILINGS IN LABS, TYP.
PT-3
PT-3
PT-3 GYP. CEILINGS
PT-1
PT-3
PT-3
PT-1
PT-1
PT-1
PT-3
PT-3 PT-3 GYP. CEILINGS
PT-3
PT-3 GYP CEILINGS
PT-3 GYP CEILINGS
PT-13 GYP CEILING
REFLECTED CEILING PLAN - GENERAL NOTES
3. LIGHTS, FIXTURES, EXIT SIGNS AND OTHER CEILING ACCESSORIES ARE SHOWN FOR FIXTURE TYPE AND LOCATION ONLY. REFER TO ENGINEERING DRAWINGS FOR INFORMATION ON POWER REQUIREMENTS, CIRCUITING SWITCHING, FIXTURE SPECIFICATIONS AND EMERGENCY LIGHTING. 4. REFER TO ENGINEER'S DRAWINGS FOR LOCATIONS OF EXHAUST FANS, STROBES, EXIT LIGHTS, GRILLS, EMERGENCY LIGHTS, SMOKE DETECTORS, ETC. 5. IF DISCREPANCY EXISTS BETWEEN DRAWINGS AND FIELD OR ARCHITECTURAL AND ENGINEERING DRAWINGS, NOTIFY ARCHITECT IMMEDIATELY.6. CENTER CEILING GRID OR TILE IN ROOM, UNLESS OTHERWISE NOTED.7. GRID START POINTS IN ROOMS WHERE CEILINGS ARE NOT CENTERED ARE INDICATED WITH X.8. GANG MULTIPLE SWITCHES WITH SINGLE COVER PLATE MOUNT. SPEC WILL LIST COLOR AND DEVICE TYPE.9. SPRINKLER HEADS AND SPRINKLER LINES ARE TO BE LOCATED SO THAT THEY WILL NOT COME IN CONFLICT WITH THE LIGHTS AS SHOWN ON THE PLAN.10. SPRINKLER HEADS INSTALLED IN WOOD CEILING SHALL BE FULLY-RECESSED AND BRONZE COLOR TO MATCH ARCHITECT
CONTROL SAMPLE; SPRINKLER HEADS INSTALLED IN GWB CEILINGS SHALL BE FULLY RECESSED; COVER PLATES SHALL BE WHITE. 11. CUT ACT TILE OR EXPOSED EDGES SHALL BE TREATED WITH AN ARMSTRONG OR EQUAL CEILING PANEL TOUCH-UP PAINT.12. EXIT SIGNS TO BE CENTERED ON HALLWAY OR OPENING AND IN CENTER OF APC IF APPLICABLE, UOI13. PAINT EXPOSED DUCTS, CABLES, J-BOXES, SPRINKLER PIPES, AND OTHER EQUIPMENT TO MATCH CEILING.14. ACOUSTICAL CEILING PANELS (EXCEPT AT ANGLED FACES) TO BE CENTERED IN ROOM, UOI15. CEILING AT CURTAINWALL OR STOREFRONT LOCATIONS TO BE ALIGNED TO BOTTOM OF MULLION, UNLESS OTHERWISE .16. PROVIDE MANUALLY OPERATED ROLLER SHADES AT ALL EXTERIOR OPENINGS (WINDOW, CURTAINWALL, AND STOREFRONT) AT WEST TOWER, WITH THE EXCEPTION OF THE LEVEL 01 AND LEVEL 05 SHELL SPACES.17. CEILING SOFFITS TO BE PAINTED PT-13 UNLESS OTHERWISE NOTED18. CEILING SOFFITS NOTED TO BE PAINTED PT-1 TO HAVE EGGSHELL FINISH19. PAINT FINISH FOR GWB CEILINGS TO BE FLAT UNLESS OTHERWISE NOTED.
1. CEILING HEIGHTS TO BE AT 9' - 11 3/8" AFF, UOI SEE NOTE 15
2. CEILING TYPE TO BE APC-1, UOI
9' - 11 3/8"
APC-1
RCP - KEY NOTES:
1 FULL TILE AT THIS LOCATION.
2 CENTER FIXTURE QUANTITY IN GWB SOFFIT. 5'-0" SPACING, TYP.
3 PENDANT PLACEMENT TO BE COORDINATED W/ FURNITURE AT A LATER DATE
R3 NO CEILING
R4 MTL PANEL CLAD SOFFIT
R5 18" GLASS DRAFT STOP
R10 EXHAUST HOOD, REF MECH DWGS
R15 ACCESS PANEL
R17 RATED ACCESS PANEL
LAY IN FIXTURE
RECESSED DOWNLIGHT
WALL WASHER
REFLECTED CEILING PLAN SYMBOLS LEGEND
9'-0" CEILING HEIGHT TAG
2'x2' SUPPLY DIFFUSER
2'x2' EXHAUST2'x4'
CEILING MOUNTED PROJECTOR (NIC),REFER TO AV DRAWINGS
LIGHTING MECHANICAL
AUDIO/VISUAL
CEILING CAMERA
FIRE PROTECTION
SPRINKLER HEAD
OCCUPANCY SENSOR
MISC
SPRINKLER
SMOKE DETECTOR
HEAT DETECTOR
EXIT FIXTURES, REFER TO ELEC DWGS
2'x2'
CABLE TRAY
253542 PENDANT LIGHTING FIXTURE
CEILING MIC
ACCESS PANEL
LAY IN FIXTURE
PENDANT LIGHTING FIXTURE
RECESSED LIGHTING FIXTURE
PENDANT LIGHTING FIXTURE
LINEAR DIFFUSER IN SOFFIT WALL
EXHAUST DUCT ABOVE SHALL BE ENCLOSED IN A HORIZONTAL FIRE RATED ASSEMBLY AFTER EXITING FIRE CONTROL AREA
FUTURE PROJECTION SCREEN
PROJECTION SCREEN6
REFLECTED CEILING PLAN - LEGEND
SYMBOL CEILING
TYPE NOTES
REFER TO FINISH LEGEND / SHEET A8.00 BACK OF HOUSE, UTILITY.
CEILINGS AND SOFFITS PT-13 UNLESS OTHERWISE NOTED.
REFER TO FINISH LEGEND / SHEET A8.00 CORRIDORS
SYMBOL SHADE
TYPE NOTES
SH-1MANUAL ROLLER SHADE WITH SHADE MATERIAL WS-1. SEE FINISH LEGEND FOR MORE INFORMATION
REFER TO FINISH LEGEND / SHEET A8.00 ATRIUM, CORRIDORS
EXP
GYP-1
ACP-1
REFER TO FINISH LEGEND / SHEET A8.00 OFFICES, LABS, CLASSROOMS, UTILITY.
ACP-2
AWC-1
REFER TO FINISH LEGEND / SHEET A8.00 ATRIUM.
ACP-3
EXPANSION JOINT COVER SCHEDULE
EXTERIOR EXPANSION JOINT COVERS (EM-SEAL BRAND OR EQ)
XEJC-01
INTERIOR EXPANSION JOINT COVERS (CS BRAND OR EQ)
XEJC-10
DUAL-SIDED EXPANSION JOINT
FOR PRIMARY USE
ROOF EXPANSION JOINT
EJC-02 FLOOR-TO-WALL
EJC-01 FLOOR-TO-FLOOR
EJC-10 CEILING-TO-CEILING
XEJC-00 DUAL-SIDED BELOW GRADE
EXPANSION JOINT FOR
PRIMARY USE
PRE-COMPRESSED, SILICONE-AND-
IMPREGNATED FOAM
TAG DESCRIPTION SYSTEM
PRE-COMPRESSED, SILICONE-AND-
IMPREGNATED FOAM
EXTRUDED THERMO-PLASTIC
RUBBER SYSTEM
EXTRUDED ALUMINUM PAN
EXTRUDED ALUMINUM PAN
EXTRUDED ALUMINUM FRAME
W/FLEXIBLE GASKET
EJC-11 CEILING-TO-WALL EXTRUDED ALUMINUM FRAME
W/FLEXIBLE GASKET
EJC-12 WALL-TO-WALL EXTRUDED ALUMINUM FRAME
W/FLEXIBLE GASKET
Th
ese d
raw
ing
s a
re t
he p
rop
ert
y o
f W
ats
on T
ate
Savo
ry,
Inc.
and
may n
ot
be u
se
d in w
ho
le o
r in
part
with
ou
t w
ritt
en c
onsent
of
the a
rch
itects
and
any
infr
ing
em
en
t is
su
bje
ct
to leg
al actio
n.
Project Number:
Date:
Revisions:
NO. ISSUED FOR DATE
CLA
SS
RO
OM
/LA
BO
RA
TOR
Y R
EDEV
ELO
PM
ENT
PA
CK
AG
E 4:
BU
ILD
ING
CO
NS
TRU
CTI
ON
H27-6118-FW-D
30 APRIL 2018
BIM
360
://U
SC
CT
L B
uild
ing
/US
C C
lassro
om
an
d L
ab
Ren
ova
tion
A18
.rvt
5/5
/20
20 6
:22
:39
PM
A2.14A
WEST TOWER -
LEVEL 4 - RCP
CO
LUM
BIA
, SC
UN
IVER
SIT
Y O
F S
OU
TH C
AR
OLI
NA
CONSTRUCTION DOCUMENTS
1/8" = 1'-0"A2.14A
1 WEST TOWER - LEVEL 4 - RCPN
4'0' 8' 16' 32'
4
4
4
4
4
6
6
6
14
20
20
20
20
20
20
20
20
20
PT-13 GYP CEILINGS IN ATRIUM, TYP
20
34
34
34
34
34
34
4 Addendum 02 02/01/18
6 OSE/Coordination 02/26/18
8 Conformed Set 04/30/18
14 Const. Bulletin 4.09 11/07/2018
18 RFI 00161 01/10/19
20 Const. Bulletin 4.15 02/06/19
34 Const. Bulletin 4.24 08/21/19
FOR INFORMATION ONLYADDENDUM 03 - 05.06.20