04-pump curves 400 series

44
Wood Group ESP, Inc. Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-1 ENGINEERING DATA TD-150 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 543 STAGES SHAFT DIAMETER 1/2 IN. HIGH STRENGTH 864 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .1963 IN. STANDARD (230ºF BHT MAX) 596 STAGES HIGH LOAD (250ºF BHT MAX)** 3004 STAGES SHAFT LIMIT HOUSING STANDARD 491 STAGES STANDARD 44 HP HIGH PRESSURE 590 STAGES HIGH STRENGTH 70 HP HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Upload: juliancho-gomez

Post on 08-Nov-2014

112 views

Category:

Documents


7 download

DESCRIPTION

curvas de bombeo PCP electrosumbergibles

TRANSCRIPT

Page 1: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-1

ENGINEERING DATA TD-150 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 543 STAGES SHAFT DIAMETER 1/2 IN. HIGH STRENGTH 864 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .1963 IN. STANDARD (230ºF BHT MAX) 596 STAGES HIGH LOAD (250ºF BHT MAX)** 3004 STAGES SHAFT LIMIT HOUSING STANDARD 491 STAGES STANDARD 44 HP HIGH PRESSURE 590 STAGES HIGH STRENGTH 70 HP HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 2: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-150 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 782 STAGES SHAFT DIAMETER 12.70 MM HIGH STRENGTH 1244 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 126.68 MM2 STANDARD (230ºF BHT MAX) 715 STAGES HIGH LOAD (250ºF BHT MAX)-** 3965 STAGES SHAFT LIMIT HOUSING STANDARD 708 STAGES STANDARD 37 HP HIGH PRESSURE 849 STAGES HIGH STRENGTH 58 HP HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 3: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-3

TD-150 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No. 1 2.1 0.64 44 20.0 19 150701 2 3.5 1.07 74 33.6 40 150702 3 4.9 1.49 105 47.6 60 150703 4 6.3 1.92 135 61.2 81 150704 5 7.8 2.38 166 75.3 102 150705 6 9.2 2.80 196 88.9 122 150706 7 10.6 3.23 226 102.5 143 150707 8 12.0 3.66 257 116.5 164 150708 9 13.4 4.08 287 130.2 184 150709

10 14.8 4.51 318 144.2 205 150710 11 16.2 4.94 348 157.8 226 150711 12 17.6 5.36 378 171.4 247 150712

Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.23 0.07 0.77 0.35 1008572 1008572

Pump to Pump Coupling - Floater 0.19 0.07 0.72 0.33 1008556 1008556

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Page 4: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 5: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-5

ENGINEERING DATA TD-300 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 855 STAGES SHAFT DIAMETER 5/8 IN. HIGH STRENGTH 1367 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3068 IN. STANDARD (230ºF BHT MAX) 373 STAGES HIGH LOAD (250ºF BHT MAX)-** 1882 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 94 HP STANDARD (230ºF BHT MAX) 226 STAGES HIGH STRENGTH 150 HP HOUSING STANDARD 481 STAGES HIGH PRESSURE 578 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 6: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-6 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-300 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 1231 STAGES SHAFT DIAMETER 15.875 MM HIGH STRENGTH 1961 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 197.93 MM2 STANDARD (230ºF BHT MAX) 448 STAGES HIGH LOAD (250ºF BHT MAX)-** 2485 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 78 HP HIGH LOAD (250ºF BHT MAX) 299 STAGES HIGH STRENGTH 125 HP HOUSING STANDARD 693 STAGES HIGH PRESSURE 832 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 7: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-7

TD-300 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No. 1 2.1 0.64 44 20.0 15 130881 14 130901 15 130921 13 130941 2 3.5 1.07 74 33.6 32 130882 31 130902 31 130922 29 130942 3 4.9 1.49 105 47.6 49 130883 48 130903 47 130923 45 130943 4 6.3 1.92 135 61.2 66 130884 65 130904 63 130924 61 130944 5 7.8 2.38 166 75.3 83 130885 82 130905 78 130925 76 130945 6 9.2 2.80 196 88.9 100 130886 98 130906 93 130926 91 130946 7 10.6 3.23 226 102.5 117 130887 109 130927 8 12.0 3.66 257 116.5 133 130888 125 130928 9 13.4 4.08 287 130.2 150 130889 140 130929 10 14.8 4.51 318 144.2 167 130890 154 130930 11 16.2 4.94 348 157.8 184 130891 171 130931 12 17.6 5.36 378 171.4 201 130892 187 130932

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.23 0.07 1.07 0.49 934281 934291

Pump to Pump Coupling - Floater Compression

0.19 0.22 0.07 0.65 0.29 926477

120555 926477 120555

Shim Kit 0.08 .02 0.06 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative. Revised March 24, 2007

Page 8: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-8 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 9: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-9

ENGINEERING DATA TD-460 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 528 STAGES SHAFT DIAMETER 5/8 IN. HIGH STRENGTH 845 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3068 IN. STANDARD (230ºF BHT MAX) 272 STAGES HIGH LOAD (250ºF BHT MAX)-** 1369 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 94 HP STANDARD (230ºF BHT MAX) 188 STAGES HIGH STRENGTH 150 HP HOUSING STANDARD 350 STAGES HIGH PRESSURE 420 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 10: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-10 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-460 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 760 STAGES SHAFT DIAMETER 15.875 MM HIGH STRENGTH 1217 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 197.93 MM2 STANDARD (230ºF BHT MAX) 326 STAGES HIGH LOAD (250ºF BHT MAX)-** 1807 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 78 HP HIGH LOAD (250ºF BHT MAX) 248 STAGES HIGH STRENGTH 125 HP HOUSING STANDARD 504 STAGES HIGH PRESSURE 605 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 11: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-11

TD-460 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No. 1 2.1 0.64 44 20.0 16 160401 15 160381 15 160551 14 160571 2 3.5 1.07 74 33.6 34 160402 33 160382 32 160552 31 160572 3 4.9 1.49 105 47.6 52 160403 50 160383 48 160553 47 160573 4 6.3 1.92 135 61.2 69 160404 68 190384 65 160554 64 160574 5 7.8 2.38 166 75.3 87 160405 86 160385 81 160555 79 160575 6 9.2 2.80 196 88.9 105 160406 100 160386 97 160556 95 160576 7 10.6 3.23 226 102.5 123 160407 113 160557 8 12.0 3.66 257 116.5 140 160408 129 160558 9 13.4 4.08 287 130.2 158 160409 146 160559

10 14.8 4.51 318 144.2 176 160410 162 160560 11 16.2 4.94 348 157.8 194 160411 179 160561 12 17.6 5.36 378 171.4 211 160412 195 160562

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake 0.23 0.07 0.77 0.35 934281 934281

Pump to Pump Coupling - Floater Compression

0.19 0.22 0.07 0.65 0.29 926477

120555 926477 120555

Shim Kit 0.08 .02 0.06 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative. Revised March 24, 2007

Page 12: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-12 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 13: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-13

ENGINEERING DATA TD-650 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 409 STAGES SHAFT DIAMETER 5/8 IN. HIGH STRENGTH 654 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3068 IN. STANDARD (230ºF BHT MAX) 270 STAGES HIGH LOAD (250ºF BHT MAX)-** 1361 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 94 HP STANDARD (230ºF BHT MAX) 206 STAGES HIGH STRENGTH 150 HP HOUSING STANDARD 348 STAGES HIGH PRESSURE 417 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

revised July 24, 2006

Page 14: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-14 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-650 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 589 STAGES SHAFT DIAMETER 15.875 MM HIGH STRENGTH 942 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 197.93 MM2 STANDARD (230ºF BHT MAX) 324 STAGES HIGH LOAD (250ºF BHT MAX)-** 1796 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 78 HP HIGH LOAD (250ºF BHT MAX) 272 STAGES HIGH STRENGTH 125 HP HOUSING STANDARD 501 STAGES HIGH PRESSURE 601 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

revised July 24, 2006

Page 15: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-15

TD-650 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No. 1 2.1 0.64 44 20.0 18 131141 15 130111 17 118081 14 130121 2 3.5 1.07 74 33.6 37 131142 33 130112 35 118082 31 130122 3 4.9 1.49 105 47.6 56 131143 50 130113 52 118083 47 130123 4 6.3 1.92 135 61.2 76 131144 68 130114 71 118084 64 130124 5 7.8 2.38 166 75.3 95 131145 86 130115 88 118085 79 130125 6 9.2 2.80 196 88.9 114 131146 100 130116 105 118086 91 130126 7 10.6 3.23 226 102.5 133 131147 123 118087 8 12.0 3.66 257 116.5 153 131148 141 118088 9 13.4 4.08 287 130.2 172 131149 158 118089 10 14.8 4.51 318 144.2 191 131150 176 118090 11 16.2 4.94 348 157.8 210 131151 193 118091 12 17.6 5.36 378 171.4 230 131152 211 118092

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.23 0.07 0.70 0.32 934281 934281

Pump to Pump Coupling –Floater Compression

0.19 0.21

0.06 0.06

0.77 0.77

0.35 0.35

926477 120555

926477 120555

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Page 16: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-16 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 17: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-17

ENGINEERING DATA TD-850 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 303 STAGES SHAFT DIAMETER 5/8 IN. HIGH STRENGTH 485 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3068 IN. STANDARD (230ºF BHT MAX) 272 STAGES HIGH LOAD (250ºF BHT MAX)-** 1369 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 94 HP STANDARD (230ºF BHT MAX) 199 STAGES HIGH STRENGTH 150 HP HOUSING STANDARD 350 STAGES HIGH PRESSURE 420 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 18: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-18 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-850 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 437 STAGES SHAFT DIAMETER 15.875 MM HIGH STRENGTH 699 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 197.93 MM2 STANDARD (230ºF BHT MAX) 326 STAGES HIGH LOAD (250ºF BHT MAX)-** 1807 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 78 HP HIGH LOAD (250ºF BHT MAX) 262 STAGES HIGH STRENGTH 125 HP HOUSING STANDARD 504 STAGES HIGH PRESSURE 605 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 19: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-19

TD-850 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No. 1 2.1 0.64 44 20.0 16 123501 15 130591 15 123521 14 130601 2 3.5 1.07 74 33.6 34 123502 33 130592 32 123522 31 130602 3 4.9 1.49 105 47.6 52 123503 50 130593 48 123523 47 130603 4 6.3 1.92 135 61.2 69 123504 68 130594 65 123524 64 130604 5 7.8 2.38 166 75.3 87 123505 86 130595 81 123525 79 130605 6 9.2 2.80 196 88.9 105 123506 100 130596 97 123526 91 130606 7 10.6 3.23 226 102.5 123 123507 113 123527 8 12.0 3.66 257 116.5 140 123508 129 123528 9 13.4 4.08 287 130.2 158 123509 145 123529 10 14.8 4.51 318 144.2 176 123510 162 123530 11 16.2 4.94 348 157.8 194 123511 178 123531 12 17.6 5.36 378 171.4 211 123512 194 123532

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.23 0.07 0.70 0.32 934281 934281

Pump to Pump Coupling –Floater Compression

0.19 0.21

0.06 0.06

0.77 0.77

0.35 0.35

926477 120555

926477 120555

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Page 20: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-20 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 21: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-21

ENGINEERING DATA TD-1200 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 338 STAGES SHAFT DIAMETER 11/16 IN. HIGH STRENGTH 541 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3712 IN. STANDARD (230ºF BHT MAX) 248 STAGES HIGH LOAD (250ºF BHT MAX)-** 1249 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 125 HP STANDARD (230ºF BHT MAX) 176 STAGES HIGH STRENGTH 200 HP HOUSING STANDARD 386 STAGES HIGH PRESSURE 464 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 22: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-22 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-1200 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 486 STAGES SHAFT DIAMETER 17.463 MM HIGH STRENGTH 778 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 239.50 MM2 STANDARD (230ºF BHT MAX) 297 STAGES HIGH LOAD (250ºF BHT MAX)-** 1648 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 104 HP HIGH LOAD (250ºF BHT MAX) 232 STAGES HIGH STRENGTH 167 HP HOUSING STANDARD 556 STAGES HIGH PRESSURE 668 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 23: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-23

TD-1200 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No. 1 2.1 0.64 44 20.0 16 123541 14 130161 15 130571 13 130171 2 3.5 1.07 74 33.6 33 123542 32 130162 31 130572 30 130172 3 4.9 1.49 105 47.6 50 123543 49 130163 46 130573 45 130173 4 6.3 1.92 135 61.2 67 123544 66 130164 63 130574 61 130174 5 7.8 2.38 166 75.3 84 123545 83 130165 78 130575 77 130175 6 9.2 2.80 196 88.9 100 123546 100 130166 93 130576 91 130176 7 10.6 3.23 226 102.5 119 123547 110 130577 8 12.0 3.66 257 116.5 135 123548 125 130578 9 13.4 4.08 287 130.2 153 123549 140 130579 10 14.8 4.51 318 144.2 170 123550 156 130580 11 16.2 4.94 348 157.8 186 123551 172 130581 12 17.6 5.36 378 171.4 204 123552 187 130582

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.21 0.06 0.77 0.35 934232 934232

Pump to Pump Coupling –Floater Compression

0.20 0.21

0.06 0.07

0.50 0.50

0.23 0.23

934182 120556

934182 120556

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Page 24: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-24 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 25: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-25

ENGINEERING DATA TD-1750 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 329 STAGES SHAFT DIAMETER 11/16 IN. HIGH STRENGTH 526 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3712 IN. STANDARD (230ºF BHT MAX) 253 STAGES HIGH LOAD (250ºF BHT MAX)-** 1274 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 125 HP STANDARD (230ºF BHT MAX) 380 STAGES HIGH STRENGTH 200 HP HOUSING STANDARD 394 STAGES HIGH PRESSURE 473 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 26: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-26 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-1750 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 474 STAGES SHAFT DIAMETER 17.463 MM HIGH STRENGTH 758 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 239.50 MM2 STANDARD (230ºF BHT MAX) 303 STAGES HIGH LOAD (250ºF BHT MAX)-** 1682 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 104 HP HIGH LOAD (250ºF BHT MAX) 501 STAGES HIGH STRENGTH 167 HP HOUSING STANDARD 568 STAGES HIGH PRESSURE 681 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 27: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-27

TD-1750 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression

Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part

No. Stgs. Part No. Stgs. Part

No. 1 2.1 0.64 44 20.0 8 939801 7 130181 8 110651 7 130201 2 3.5 1.07 74 33.6 16 939819 15 130182 16 110652 15 130202 3 4.9 1.49 105 47.6 25 939827 24 130183 25 110653 24 130203 4 6.3 1.92 135 61.2 33 939835 32 130184 33 110654 32 130204 5 7.8 2.38 166 75.3 41 939868 41 130185 41 110655 41 130205 6 9.2 2.80 196 88.9 50 939876 49 130186 50 110656 49 130206 7 10.6 3.23 226 102.5 58 939884 57 130187 58 110657 57 130207 8 12.0 3.66 257 116.5 67 939892 66 130188 67 110658 66 130208 9 13.4 4.08 287 130.2 75 939900 74 130189 75 110659 74 130209 10 14.8 4.51 318 144.2 84 939918 83 130190 84 110660 83 130210 11 16.2 4.94 348 157.8 92 939926 91 130191 92 110661 91 130211 12 17.6 5.36 378 171.4 100 939934 100 130192 100 110662 100 130212 13 19.0 5.79 408 183.6 108 399942 108 110663 14 20.4 6.22 438 197.10 116 939959 116 110664 15 21.8 6.64 468 210.60 125 939967 125 110665

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.21 0.06 0.77 0.35 934232 934232

Pump to Pump Coupling –Floater Compression

0.20 0.21

0.06 0.07

0.50 0.50

0.23 0.23

934182 120556

934182 120556

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Page 28: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-28 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 29: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-29

ENGINEERING DATA TD-2200 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 198 STAGES SHAFT DIAMETER 11/16 IN. HIGH STRENGTH 317 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .3712 IN. STANDARD (230ºF BHT MAX) 224 STAGES HIGH LOAD (250ºF BHT MAX)-** 1128 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 125 HP STANDARD (230ºF BHT MAX) 335 STAGES HIGH STRENGTH 200 HP HOUSING STANDARD 349 STAGES HIGH PRESSURE 419 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 30: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-30 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-2200 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 286 STAGES SHAFT DIAMETER 17.463 MM HIGH STRENGTH 457 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 239.50 MM2 STANDARD (230ºF BHT MAX) 269 STAGES HIGH LOAD (250ºF BHT MAX)-** 1489 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 104 HP HIGH LOAD (250ºF BHT MAX) 442 STAGES HIGH STRENGTH 167 HP HOUSING STANDARD 502 STAGES HIGH PRESSURE 603 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 31: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-31

TD-2200 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression

Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part

No. Stgs. Part No. Stgs. Part

No. 1 2.1 0.64 44 20.0 8 130981 7 131781 8 132941 7 132961 2 3.5 1.07 74 33.6 16 130982 15 131782 16 132942 15 132962 3 4.9 1.49 105 47.6 25 130983 24 131783 25 132943 24 132963 4 6.3 1.92 135 61.2 33 130984 32 131784 33 132944 32 132964 5 7.8 2.38 166 75.3 41 130985 41 131785 41 132945 41 132965 6 9.2 2.80 196 88.9 50 130986 49 131786 50 132946 49 132966 7 10.6 3.23 226 102.5 58 130987 57 131787 58 132947 57 132967 8 12.0 3.66 257 116.5 67 130988 66 131788 67 132948 66 132968 9 13.4 4.08 287 130.2 75 130989 74 131789 75 132949 74 132969 10 14.8 4.51 318 144.2 84 130990 83 131790 84 132950 83 132970 11 16.2 4.94 348 157.8 92 130991 91 131791 92 132951 91 132971 12 17.6 5.36 378 171.4 100 130992 100 131792 100 132952 100 132972 13 19.0 5.79 408 183.6 108 130993 108 132953 14 20.4 6.22 438 197.10 116 130994 116 132954 15 21.8 6.64 468 210.60 125 130995 125 132955

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.21 0.06 0.77 0.35 934232 934232

Pump to Pump Coupling –Floater Compression

0.20 0.21

0.06 0.07

0.50 0.50

0.23 0.23

934182 120556

934182 120556

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Page 32: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-32 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 33: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-33

ENGINEERING DATA TD-3000 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 400 STAGES SHAFT DIAMETER 7/8 IN. HIGH STRENGTH 640 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .6013 IN. STANDARD (230ºF BHT MAX) 163 STAGES HIGH LOAD (250ºF BHT MAX)-** 823 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 256 HP STANDARD (230ºF BHT MAX) 349 STAGES HIGH STRENGTH 410 HP HOUSING STANDARD 413 STAGES HIGH PRESSURE 495 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 34: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-34 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-3000 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 576 STAGES SHAFT DIAMETER 22.225 MM HIGH STRENGTH 922 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 387.95 MM2 STANDARD (230ºF BHT MAX) 196 STAGES HIGH LOAD (250ºF BHT MAX)-** 1087 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 213 HP HIGH LOAD (250ºF BHT MAX) 460 STAGES HIGH STRENGTH 341 HP HOUSING STANDARD 594 STAGES HIGH PRESSURE 713 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 35: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-35

TD-3000 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression

Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part

No. Stgs. Part No. Stgs. Part

No. 1 2.1 0.64 44 20.0 6 936260 6 130241 6 110671 6 130261 2 3.5 1.07 74 33.6 14 936278 14 130242 14 110672 14 130262 3 4.9 1.49 105 47.6 21 936286 21 130243 21 110673 21 130263 4 6.3 1.92 135 61.2 29 936294 29 130244 29 110674 29 130264 5 7.8 2.38 166 75.3 36 936302 36 130245 36 110675 36 130265 6 9.2 2.80 196 88.9 44 936310 44 130246 44 110676 44 130266 7 10.6 3.23 226 102.5 51 936328 51 130247 51 110677 51 130267 8 12.0 3.66 257 116.5 59 936336 59 130248 59 110678 59 130268 9 13.4 4.08 287 130.2 66 936344 66 130249 66 110679 66 130269 10 14.8 4.51 318 144.2 74 936351 74 130250 74 110680 74 130270 11 16.2 4.94 348 157.8 81 936369 81 130251 81 110681 81 130271 12 17.6 5.36 378 171.4 89 936377 89 130252 89 110682 89 130272 13 19.0 5.79 408 183.6 96 936385 96 130253 96 110683 96 130273 14 20.4 6.22 438 197.10 104 936393 100 130254 104 110684 100 130274 15 21.8 6.64 468 210.60 111 936401 111 110685

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 3/8”-8rd) 0.6 0.18 10 4.5 930941 930941

Coupling for Intake or GS 0.21 0.06 0.77 0.35 934026 934026

Pump to Pump Coupling –Floater Compression

0.20 0.21

0.06 0.07

0.50 0.50

0.23 0.23

934026 120557

934026 120557

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative. Revised December 29, 2006

Page 36: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-36 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 37: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-37

ENGINEERING DATA TD-4300 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 253 STAGES SHAFT DIAMETER 7/8 IN. HIGH STRENGTH 406 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .6013 IN. STANDARD (230ºF BHT MAX) 146 STAGES HIGH LOAD (250ºF BHT MAX)-** 826 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 256 HP STANDARD (230ºF BHT MAX) 267 STAGES HIGH STRENGTH 410 HP HOUSING STANDARD 414 STAGES HIGH PRESSURE 497 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 38: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-38 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-4300 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 365 STAGES SHAFT DIAMETER 22.225 MM HIGH STRENGTH 584 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 387.95 MM2 STANDARD (230ºF BHT MAX) 197 STAGES HIGH LOAD (250ºF BHT MAX)-** 1091 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 213 HP HIGH LOAD (250ºF BHT MAX) 352 STAGES HIGH STRENGTH 341 HP HOUSING STANDARD 596 STAGES HIGH PRESSURE 715 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 39: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-39

TD-4300 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression

Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part

No. Stgs. Part No. Stgs. Part

No. 1 2.1 0.64 44 20.0 4 130391 4 130741 4 132541 4 132561 2 3.5 1.07 74 33.6 8 130392 8 130742 8 132542 8 132562 3 4.9 1.49 105 47.6 13 130393 13 130743 13 132543 13 132563 4 6.3 1.92 135 61.2 17 130394 17 130744 17 132544 17 132564 5 7.8 2.38 166 75.3 22 130395 22 130745 22 132545 22 132565 6 9.2 2.80 196 88.9 27 130396 27 130746 27 132546 27 132566 7 10.6 3.23 226 102.5 31 130397 31 130747 31 132547 31 132567 8 12.0 3.66 257 116.5 36 130398 35 130748 36 132548 35 132568 9 13.4 4.08 287 130.2 40 130399 40 130749 40 132549 40 132569 10 14.8 4.51 318 144.2 45 130400 45 130750 45 132550 45 132570 11 16.2 4.94 348 157.8 49 130401 49 130751 49 132551 49 132571 12 17.6 5.36 378 171.4 54 130402 54 130752 54 132552 54 132572 13 19.0 5.79 408 183.6 59 130403 58 130753 59 132553 58 132573 14 20.4 6.22 438 197.10 63 130404 63 130754 63 132554 63 132574 15 21.8 6.64 468 210.60 68 130405 68 130755 68 132555 68 132575

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 7/8”-8rd) 0.6 0.18 10 4.5 132160 132160

Coupling for Intake or GS 0.21 0.06 0.77 0.35 934026 934026

Pump to Pump Coupling –Floater Compression

0.20 0.21

0.06 0.07

0.50 0.50

0.23 0.23

934026 120557

934026 120557

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative. Revised December 29, 2006

Page 40: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-40 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

Page 41: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-41

ENGINEERING DATA TD-6000 60 HZ HOUSING DIAMETER 4.00 IN. ROTATIONAL DIRECTION CCW

MINIMUM CASING SIZE 5-1/2 IN. MAXIMUM STAGING:* SHAFT STANDARD 182 STAGES SHAFT DIAMETER 7/8 IN. HIGH STRENGTH 290 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA .6013 IN. STANDARD (230ºF BHT MAX) 157 STAGES HIGH LOAD (250ºF BHT MAX)-** 789 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 256 HP STANDARD (230ºF BHT MAX) 222 STAGES HIGH STRENGTH 410 HP HOUSING STANDARD 396 STAGES HIGH PRESSURE 475 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 1190 LBS. HIGH LOAD (250ºF BHT MAX) 6000 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 42: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-42 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004

ENGINEERING DATA TD-6000 50 HZ HOUSING DIAMETER 101.6 MM ROTATIONAL DIRECTION CCW MINIMUM CASING SIZE 139.7 MM MAXIMUM STAGING:* SHAFT STANDARD 261 STAGES SHAFT DIAMETER 22.225 MM HIGH STRENGTH 418 STAGES THRUST BEARING – FLOATER PUMP MINIMUM SHAFT AREA 387.95 MM2 STANDARD (230ºF BHT MAX) 188 STAGES HIGH LOAD (250ºF BHT MAX)-** 1042 STAGES SHAFT LIMIT THRUST BEARING – COMPRESSION PUMP STANDARD 213 HP HIGH LOAD (250ºF BHT MAX) 293 STAGES HIGH STRENGTH 341 HP HOUSING STANDARD 570 STAGES HIGH PRESSURE 684 STAGES HOUSING PRESSURE LIMIT STANDARD 5000 PSI THRUST BEARING CAPACITY HIGH PRESSURE 6000 PSI STANDARD (230ºF BHT MAX) 992 LBS. HIGH LOAD (250ºF BHT MAX) 5500 LBS. * - Maximum staging may be limited by pumped fluid specific gravity, housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your local Wood Group ESP representative.

Page 43: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004 Page-43

TD-6000 PUMP 400 Series STANDARD PUMP ABRASION RESISTANT PUMP

Length Weight Floater Compression Floater Compression

Hsg Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part

No. Stgs. Part No. Stgs. Part

No. 1 2.1 0.64 44 20.0 4 131901 4 131921 4 132581 4 132601 2 3.5 1.07 74 33.6 8 131902 8 131922 8 132582 8 132602 3 4.9 1.49 105 47.6 13 131903 13 131923 13 132583 13 132603 4 6.3 1.92 135 61.2 17 131904 17 131924 17 132584 17 132604 5 7.8 2.38 166 75.3 22 131905 22 131925 22 132585 22 132605 6 9.2 2.80 196 88.9 27 131906 27 131926 27 132586 27 132606 7 10.6 3.23 226 102.5 31 131907 31 131927 31 132587 31 132607 8 12.0 3.66 257 116.5 36 131908 35 131928 36 132588 35 132608 9 13.4 4.08 287 130.2 40 131909 40 131929 40 132589 40 132309 10 14.8 4.51 318 144.2 45 131910 45 131930 45 132590 45 132610 11 16.2 4.94 348 157.8 49 131911 49 131931 49 132591 49 132611 12 17.6 5.36 378 171.4 54 131912 54 131932 54 132592 54 132612 13 19.0 5.79 408 183.6 59 131913 58 131933 59 132593 58 132613 14 20.4 6.22 438 197.10 63 131914 63 131934 63 132594 63 132614 15 21.8 6.64 468 210.60 68 131915 68 131935 68 132595 68 132615

NOTE: COMPRESSION PUMPS REQUIRE A SEAL WITH A HIGH LOAD THRUST BEARING. Length Weight STANDARD PUMP AR PUMP Feet Meters Lbs. Kgs. Part No. Part No. Bolt on Head (2 7/8”-8rd) 0.6 0.18 10 4.5 132160 132160

Coupling for Intake or GS 0.21 0.06 0.77 0.35 934026 934026

Pump to Pump Coupling –Floater Compression

0.20 0.21

0.06 0.07

0.50 0.50

0.23 0.23

934026 120557

934026 120557

Shim Kit 0.08 0.02 0.02 0.03 131612 131612

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative. Revised December 29, 2006

Page 44: 04-Pump Curves 400 Series

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-44 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - January, 2004