~ notes ~ line post hot rolled hot rolled roll formed … · 1¼'' nps top rail &...
TRANSCRIPT
12-01-15
12-01-15
. .
.
.
CORNER OR INTERMEDIATE PULL POST
1
3
3
SEE END POST
FOR DIMENSIONS
2 LINE POST
2 LINE POST4END POST1 4
3'-
6'' F
OR 6'
FE
NC
E
~ NOTES ~
LEGEND / (ALTERNATES)
TUBULAR ROLL FORMED
1
APPROVED CAPS
BRACE BAND AND TENSION BAND
2
3
4
5
6
7
8
- OR -
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
BRACE AND TRUSS
CAP OR FITTED
OVER CLAMP
TRUSS TIGHTENER
TERMINAL POST &
CORNER POST
LINE POST
H - COLUMN
+
LINE POST
TOP & BRACE
RAIL
CLASS ''B'' CONCRETE (TYP)
3
5
CONNECTOR
HEAVY ''C'' ROLL FORMED
¼'' R
3'-
0'' F
OR 4'
FE
NC
E
2'-
6'' F
OR 4'
3'-
0'' F
OR 6'
1'-6''
2''
10'-0'' MAX.
1'-0''
2'-
6'' F
OR 4'
3'-
0'' F
OR 6'
2'-
0'' F
OR 4'
2'-
6'' F
OR 6'
10'-0'' MAX.
3½''
0.135''
''
2¼''0.125
0.121
1?''¾"
2¼''
1¼''
1?''0.080''
2½'' NPS END POST
2'' NPS LINE POST
?'' DIA.TRUSS ROD AND TIGHTNER
1¼'' NPS BRACE
3½'' X 3½'' END POST
2¼'' H-COL. LINE POST
2¼'' C-COL. LINE POST
?" DIA. TRUSS ROD AND TIGHTNER
1¼'' X 1?'' TOP RAIL & BRACE
1¼'' X 1?'' BRACE
ALL FENCE FITTINGS SHALL COMPLY WITH ASTM F626.
ALL POSTS SHALL BE SET IN CONCRETE TO THE DIMENSIONS INDICATED
ON THIS DRAWING.
4' HIGH FENCE SHALL HAVE 4' FABRIC HEIGHT. 6' HIGH FENCE SHALL HAVE
6' FABRIC HEIGHT.
POST CAPS AND SOCKET TYPE BRACE END CONNECTIONS SHALL BE GALVA-
NIZED PRESSED STEEL, CAST IRON OR OTHER TYPE AS APPROVED BY THE
FROM INSIDE POSTS AND RAILS.
NPS = NOMINAL PIPE SIZE - ASTM F1083 AND F1043 (HEAVY INDUSTRIAL
FENCE) SHALL GOVERN.
INDISCRIMINATE MIXING OF POSTS WILL NOT BE PERMITTED.
TENSION WIRE COMPLYING WITH ASTM A 824 SHALL BE SUBSTITUTED FOR THE
TOP RAIL WHEN THE FENCE IS TO BE INSTALLED IN THE PATH OF AN ERRANT
VEHICLE.
9.
HOT ROLLED HOT ROLLED
FLAT TENSION BAR
ROLL FORMED
RFC-001-08
6
5
87
5
7
1?
11.
12.
13.
14.
15.
BID ITEMS AND UNIT TO BID
LFCHAIN LINK FENCE
CUYDCONCRETE-CLASS B
10.
(SEE NOTE 9)1¼'' NPS TOP RAIL
ENGINEER. THEY SHALL BE DESIGNED IN A MANNER TO EXCLUDE MOISTURE
4' TO 6' HIGH
CHAIN LINK FENCE
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
¾"
3½''
12-01-15
12-01-15
. .
.
.
1
5
3
3
2 LINE POST
8
7
7
LEGEND / (ALTERNATES)
TUBULAR ROLL FORMED
1
BRACE BAND AND TENSION BAND
2
3
4
5
6
7
8 NOT REQUIRED
NOT REQUIRED
TERMINAL POST &
CORNER POST
LINE POST
H - COLUMN
CLASS ''B'' CONCRETE (TYP)
3
BARBED WIRE ARMS BARBED WIRE ARMS
BARBED WIRE BARBED WIRE
TOP & BRACE
RAIL
FOR DIMENSIONS
SEE END POST
X XXXXXXXXXXXXX
4X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
PULL POST
INTERMEDIATE
CORNER OR
~ NOTES ~
BRACE AND TRUSS
TRUSS TIGHTENER
OVER CLAMP
CAP OR FITTED
ROLL FORMED
DETAIL ''A''
X
X
X X
X
X
X
X
X X
X
XX
1 END POST
POST
END1
5 2 LINE POST
65
4
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
SEE DETAIL ''A''
CONNECTOR
ROLL FORMED HOT ROLLED ROLL FORMED
FLAT TENSION BAR
3'-
6''
1'-6''
3'-
0''
2''
3'-
6''
3'-
0''
1'-0''
1?"
1¼''
10'-0'' MAX.10'-0'' MAX.
3½''
3½''
2¼''
0.080''
0.135''
1?''
?'' DIA. TRUSS ROD AND TIGHTNER ?'' DIA. TRUSS ROD AND TIGHTNERBRACE
1¼'' x 1?''
ALL POSTS SHALL BE SET IN CONCRETE TO THE DIMENSIONS SHOWN ON THIS DRAWING.
A 1¼'' NPS OR A 1¼'' x 1?'' ROLL FORMED SECTION, BOTTOM RAIL SHALL BE REQUIRED AROUND
ALL UTILITY INSTALLATIONS AND AT OTHER LOCATIONS DESIGNATED BY THE ENGINEER.
8' HIGH FENCE SHALL HAVE 7' FABRIC HEIGHT. 9' HIGH FENCE SHALL HAVE 8' FABRIC HEIGHT.
10' HIGH FENCE SHALL HAVE 9' FABRIC HEIGHT. 11' HIGH FENCE SHALL HAVE 10' FABRIC HEIGHT.
12' HIGH FENCE SHALL HAVE 11' FABRIC HEIGHT.
NPS = NOMINAL PIPE SIZE - ASTM F1083 AND F1043 (HEAVY INDUSTRIAL FENCE) SHALL GOVERN.
2½'' NPS END POST
2'' NPS LINE POST
1¼'' NPS TOP RAIL & BRACE
3½'' X 3½'' END POST
2¼'' H-COL. LINE POST
1¼'' x 1?'' TOP RAIL & BRACE
EXCLUDE MOISTURE FROM INSIDE THE POSTS AND RAILS.
POST CAPS AND SOCKET TYPE BRACE END CONNECTIONS SHALL BE GALVANIZED PRESSED STEEL, CAST
IRON OR OTHER TYPE AS APPROVED BY THE ENGINEER. THEY SHALL BE DESIGNED IN A MANNER TO
RFC-002-05
9.
10.
11.
12.
13.
14.
BID ITEMS AND UNIT TO BID
LFCHAIN LINK FENCE
CUYDCONCRETE-CLASS B
8' TO 12' HIGH
CHAIN LINK FENCE
ALL FENCE FITTINGS SHALL COMPLY WITH ASTM F626.
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
12-01-15
12-01-15
. .
.
.
10''
LOCKING DEVICE CATCH
x x
x
xxxxxxx x x xxx x x x x x x xxxxx
10''
LOCKING DEVICE CATCH
CENTER LOCKING DEVICE
xx
xxxxxxx x x x xx x x x x x xxxxx xxx
GATES SHALL HAVE HEAVY PRESSED STEEL CORNERS SECURELY
SO AS TO BE RIGID AND WATER TIGHT. ALL WELDED JOINTS SHALL
CAP
VARIABLE 1WIRE
BARBED
LOCKING DEVICE
CENTER
VEHICULAR GATE
VEHICULAR GATE
CONNECTED TO METAL POSTS
CONNECTED TO WOOD POSTS
WELDED
ALTERNATE METHODS OF SECURING
VERTICAL STAY WIRE TO THE
HORIZONTAL WIRE OF THE FABRIC.
BRACE
4'' WOOD
4'' WOOD BRACE
4''
BARBED WIRECAP
WIRE
BRACE
8'' WOOD GATE POST
(TYPICAL)
CLASS ''B'' CONCRETE
(TYPICAL)
CLASS ''B'' CONCRETE
BE CLEANED AND PAINTED WITH TWO (2) COATS OF ALUMINUM PAINT.
VARIABLE 1
WOVEN-WIRE FABRIC USED IN THE GATES SHALL EITHER BE
ALUMINUM-COATED STEEL NO. 1047-6-9 OR ZINC-COATED STEEL
RIVETED OR SHALL BE MACHINE NOTCHED AND ELECTRICALLY WELDED2
NO. 1047-6-9.
GATE POST
8'' WOOD
FABRIC TIE WIRES SHALL BE SPACED 1'-0'' ON CENTERS.
3½'' NPS GATE POST
4'-0''
4'-3''
1'-6''
2'-0''
3''
1½'' NPS GATE FRAME
1¼'' NPS
3'-0''
2'-6''
1'-6''
7'-0''
GATE POST
2½'' NPS
GATE FRAME
1½'' NPS
HORIZ BRACE
1¼'' NPS
2'-6''
3'-0''
2'-0''
1'-6''
4'-0''
3'-6''
1'-6''
3''
4'-3''
4'-0''1¼'' NPS
1½'' NPS GATE FRAME1''
1'-0''
8'-0'' GATE FRAME
1½'' NPS
HORIZ BRACE
1¼'' NPS
4'-0''
3'-6''
1'-6''
1'-6''
AND 12' TO 26' WIDTH FOR DOUBLE GATE.
6' TO 13' WIDTH FOR SINGLE GATE
4' TO 6' WIDTH
x xx x x x
x xx x x x
CAP
PEDESTRIAN GATE
PEDESTRIAN GATE
CONNECTED TO METAL POSTS
CONNECTED TO WOOD POSTS
VARIABLE 2
VARIABLE 2
CAP
WIRE
BRACE
(TYPICAL)
CONCRETE
CLASS ''B''
(TYPICAL)
CONCRETE
CLASS ''B''
4''
4'-0''
3''
7'-0''
3''
4'-0''
8'-0''
1'-0''
1''
GATES
WOVEN WIRE
RFG-001-07
~ NOTES ~
BID ITEMS AND UNIT TO BID
EACHSINGLE VEHICULAR WOVEN WIRE GATE
EACHDOUBLE VEHICULAR WOVEN WIRE GATE
EACHPEDESTRIAN WOVEN WIRE GATE
CUYDCONCRETE-CLASS B
OR
OR
1
3.
5.
4.
6.
7.
THE CONTRACTOR IS NOT TO ORDER GATES UNTIL THEIR
ENGINEER.
NECESSITY AND LOCATION HAVE BEEN CERTIFIED BY THE
INDUSTRIAL FENCE) SHALL GOVERN.
NPS = NOMINAL PIPE SIZE - ASTM F1083 AND F1043 (HEAVY
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
12-01-15
12-01-15
. .
.
.
LEGEND / (ALTERNATES)
TUBULAR ROLL FORMED
1
2
4
5
6
7
8
3
BARBED WIRE ARMS
BARBED WIRE9
10
APPROVED CAPS
X
X
X X X X X X X X X X
X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X
X
X
X
X X X X X X X X X X X XXXXXXXXXX X X X X X X X
X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X
ALL WELDED JOINTS SHALL BE CLEANED AND PAINTED WITH TWO ( 2 ) COATS OF ALUMINUM PAINT.
11
12
VARIABLE 11
6
77 7 7 7
6
55
8
3
CLASS ''B'' CONCRETE (TYP.)
10''
LOCKING DEVICE CATCH
CENTER LOCKING DEVICE4
3
13
13
13
13
9410
3
54
X
X
X
X X X X X X
X X X X X X
X X X X X X
10 9
6
2
4
ALL POST SHALL BE SET IN CONCRETE TO THE DIMENSIONS AS INDICATED ON THIS DRAWING.
HINGE DETAIL
ROLL FORMED
OR SHALL BE MACHINE NOTCHED, AND ELECTRICALLY WELDED SO AS TO BE RIGID AND WATER TIGHT;
ALL FENCE FITTINGS SHALL COMPLY WITH ASTM F626.
VEHICULAR AND PEDESTRIAN GATES SHALL HAVE HEAVY PRESSED STEEL CORNERS SECURELY RIVETED
FLAT TENSION BAR
2'-0''
1'-6''
1'-6''VEHICULAR GATE (4' AND 6' HIGH FENCE)
4' HIGH GATES SHALL HAVE 4' FABRIC HEIGHT. 6' HIGH GATES SHALL HAVE 6' FABRIC HEIGHT.
8' HIGH GATES SHALL HAVE 7' FABRIC HEIGHT. 9' HIGH GATES SHALL HAVE 8' FABRIC HEIGHT.
10' HIGH GATES SHALL HAVE 9' FABRIC HEIGHT. 11' HIGH GATES SHALL HAVE 10' FABRIC HEIGHT.
12' HIGH GATES SHALL HAVE 11' FABRIC HEIGHT.
(8' TO 12' HIGH FENCE)
DETAIL ''A''
(8' TO 12' HIGH FENCE)
DETAIL ''B''
END POST 2½'' NPS
END POST 2½'' NPS
GATE POST 3½' NPS
GATE FRAME 1½'' NPS
1¼'' NPS
BRACE BAND AND TENSION BAND NOT REQUIRED
NOT REQUIRED
BARBED WIRE ARMS
BARBED WIRE
NOT REQUIRED
NO ALTERNATE
NO ALTERNATE
NO ALTERNATE
6
VARIABLE 12
1
8
4
57
1'-6''
(4' AND 6' HIGH FENCE)
PEDESTRIAN GATE
3½'' X 3½''
3½'' X 3½''
CHAIN LINK GATE
4' TO 12' HIGH
RFG-005-06
~ NOTES ~
INDUSTRIAL FENCE) SHALL GOVERN.
NPS = NOMINAL PIPE SIZE - ASTM F1083 AND ASTM F1043 (HEAVY
CERTIFIED BY THE ENGINEER.
THE CONTRACTOR IS NOT TO ORDER GATES UNTIL THEIR NECESSITY AND LOCATION HAVE BEEN
BID ITEMS AND UNIT TO BID
EACHSINGLE VEHICULAR CHAIN LINK GATE
EACHDOUBLE VEHICULAR CHAIN LINK GATE
EACHPEDESTRIAN CHAIN LINK GATE
CUYDCONCRETE-CLASS B
OR
OR
4' TO 6' WIDTH. SEE ELSEWHERE IN PLANS FOR GATE HEIGHT.
6' TO 13' WIDTH FOR SINGLE GATE OR 12' TO 26' WIDTH FOR DOUBLE GATE. SEE ELSEWHERE IN PLANS FOR GATE HEIGHT.
13
14.
15.
3'-0'' FOR 4' FENCE OR 3'-6'' FOR 6' FENCE. 2'-6'' FOR 4' FENCE OR 3'-0'' FOR 6' FENCE.
16.
17.
18.
19.
20.
21.
AND EQUIPPED WITH A PADLOCKING DEVICE AND GROUND STOP.
BARBED WIRE IS REQUIRED ON 8' TO 12' HIGH GATES. SEE DETAILS A AND B FOR INSTALLATION.
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
12-01-15
12-01-15
. .
.
.
+
+
+
+
DETAIL ''A'' DETAIL ''B''
x x x x x x x
45
TURNBUCKLE
FILL
COMPACTED
END POST
xxxxxxx
VARIES
VARIES
VARIES
6'' TO 8'' FLOATER LOG
CONNECTORS
ABUTMENT
SEE DETAIL ''A''6'' 6'' 6'' 6''
TYPICAL WATER GATE
ALL FENCE FITTINGS SHALL COMPLY WITH ASTM F626.
WATER GATES SHALL HAVE HEAVY PRESSED STEEL CORNERS SECURELY RIVETED OR SHALL BE MACHINE NOTCHED AND ELECTRICALLY
1¼'' NPS
PIPE
PIPE SLEEVE
1¼'' NPS
PIPE (TYP)
1¼'' NPS
FABRIC TIE WIRES SHALL BE SPACED 1'-0'' ON CENTERS. THE CONTRACTOR IS NOT TO ORDER GATES OF ANY TYPE UNTIL
THEIR NECESSITY AND LOCATION ARE CERTIFIED BY THE ENGINEER.
3''
2'-0''
12'-0'' 12'-0'' 12'-0''
CABLE
1'' STEEL
METAL
?'' STRAP
2¾''
(2 REQD.)
½'' x 1½'' BOLT
CABLE
1'' STEEL
CABLE
1'' STEEL
3'-0''
8'-0''
NPS = NOMINAL PIPE SIZE - ASTM F1083 AND F1043 (HEAVY INDUSTRIAL FENCE) SHALL GOVERN.
CABLE
1'' STEEL
x x x x x x x
WELDED SO AS TO BE RIGID AND WATER TIGHT. ALL WELDED JOINTS SHALL BE CLEANED AND PAINTED WITH TWO (2) COATS OF ALUMINUM PAINT.
3' MIN.
WOVEN-WIRE FABRIC USED ON WATER GATE TYPE 1 SHALL BE EITHER ALUMINUM-COATED STEEL NO. 1047-6-9 OR ZINC COATED STEEL NO. 1047-6-9.
1'' ANCHOR BOLT
RFG-010-05
SEE DETAIL ''B''
~ NOTES ~
1.
2.
3.
4.
5.
6.
BID ITEMS AND UNIT TO BID
EACHWATER GATE TYPE 1
CUYDCONCRETE-CLASS B
CUYDCONCRETE-CLASS A
LBSTEEL REINFORCEMENT
''B'' CONC.
ANCHOR 1 CU. YD. CLASS
4'-0'' x 2'-3'' x 3'-0'' CONC.
THIS ILLUSTRATION DEPICTS WATER GATE TYPE 1 USING WOVEN WIRE FABRIC.
TYPE 1
WATER GATE
THE ENGINEER.
DIRECTED ON CONSTRUCTION BY
SWING AND BE RIPRAPPED IF SO
MANNER AS TO ALLOW GATES TO
CHANNEL TO BE CUT IN SUCH A
REINFORCED CONC. POST
2'-0'' x 2'-0'' CLASS ''A''
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
12-01-15
12-01-15
. .
.
.
TYPE 3
WATER GATE
TYPICAL WATER GATE INSTALLATION
1.
2. COMMERCIAL GRADE ALUMINUM
2a SHEETING - 0.090'' THICK, MILL FINISH.
2c BRACING - 1½" x 1½'' X ?'' SQUARE TUBING @ 0.826 LB./LIN. FT.
3 EYEBOLT ''A'' - GALVANIZED, WELDLESS, ½'' DIA., 6'' SHANK, 1'' EYE I.D., 3'' THREAD.
4 EYEBOLT ''B'' - GALVANIZED, WELDLESS, ½'' DIA., 2½'' SHANK, 1'' EYE I.D., 1'' THREAD.
5
6 HEX FULL NUTS AND JAM NUTS - ½'' DIA., 13 THREADS/IN., FINISHED, DOUBLE CHAMFERED.
7 STEEL WASHER - ?'' I.D., 2¾'' O.D.
EXPANSION ANCHORS - 6000 LBS. MINIMUM HOLDING POWER.8
WELD ANGLE AND BRACE CONNECTIONS FULLY ON ALL EXPOSED SIDES.
WELD SHEETING ON BOTH SIDES TO ANGLES AND BRACING AS SHOWN.
11.
9.
10.
LENGTH, 2‚'' THREAD, ½'' DIA.
SECTIONS PER OPENING WITH 3'' GAP BETWEEN SECTIONS (SEE DETAIL ''A''). NO SECTION
SHALL EXCEED 10' IN WIDTH.
12.
SHEET IS USED AND THE SEAMS DO NOT FIT THE MINIMUM REQUIRED BRACING DIAGRAM,
ADDITIONAL SYMMETRICALLY PLACED BRACING SHALL BE REQUIRED. NO SEAMS SHALL BE
VISIBLE FROM THE BRACING SIDE OF THE GATE.
7½'' 7½''
5½''
3''
3''
6''
½'' (TYP)FLOOR OF CULVERT
CEILING
CULVERTCULVERT
TOP OF
ANGLE
ALUMINUM
SHEETING
ALUMINUM
SPACED
EQUALLY
2a ALUMINUM SHEETING LINE
2a
2b ANGLES - 2'' x 2'' x ?'' @ 1.60 LBS./LIN. FT.
SPACED
EQUALLY
SPACED
EQUALLY
2b
5½''
BRACING
ALUMINUM2c
A
A
SECTION A-A
3 EYE BOLT ''A''
SHEETING
ALUMINUM2a
½'' (TYP)
3''
SECTION A-A
HANGER SYSTEM
EXISTING CONSTRUCTION
HANGER SYSTEM
NEW CONSTRUCTION
8 EXPANSION ANCHOR
DETAIL ''A''
1'-0''
3''
( 2 OR MORE SECTIONS )
IN SKEWED CULVERTS
WATER GATE LOCATION
IN CULVERTS AT 90
WATER GATE LOCATION
1-V
WIDE
4'-6'
WIDE
7'-8'
WIDE
9'-10' 11'-16' WIDE 17'-20' WIDE
2-V, 1-H 3-V, 1-H 2-V, 1-H 2-V, 1-H 3-V, 1-H 3-V, 1-H
MINIMUM HOR. AND VER. BRACING SYSTEMS FOR VARIOUS WIDTH CULVERT
OPENINGS.
ONE (1) ADDITIONAL HOR. BRACE REQUIRED FOR CULVERT OVER 10' IN HEIGHT.
FLOW
1'-6''
SHEETING SIDE OF GATE
FLOW
1'-6''
SHEETING SIDE OF GATE
FULL HEX NUT
HEX JAM NUTS
5 U-BOLT
CEILING
CULVERT
WASHER
STEEL7HEX NUTS
FULL
ANGLE
ALUMINUM2b
3''
FULL HEX NUT
HEX JAM NUTS
BRACING
ALUMINUM2c
5 U-BOLT
CEILING
CULVERT
SHEETING
ALUMINUM2a
½'' (TYP)
ANGLE
ALUMINUM2b
4 EYE BOLT ''B''
¼ 2-7BRACING
SHEET
ANGLE
SEAM WELDS
BRACING AND SHEET
SHEET SHEET
BRACING
2-7
BRACING
SHEET
BRACING
BRACING WELDS
BRACING AND
2-7?
BRACING
ALUMINUM2c
AND SHEET WELDS
BRACING, ANGLE
2-7
2-7
ANGLE
ANGLESHEET
WELDS
CORNER JOINT
SHEET LINE
USE OF ONE CONTINUOUS ALUMINUM SHEET IS DESIRABLE; HOWEVER IF MORE THAN ONE
U-BOLTS - CADMIUM PLATED STEEL, 3'' BETWEEN LEGS, 4½'' INSIDE LENGTH, 5'' OUTSIDE
~ NOTES ~
RFG-011-06
BID ITEM AND UNIT TO BID
EACHWATER GATE TYPE 3
THE CONTRACT UNIT PRICE SHALL INCLUDE LABOR, MATERIALS, INSTALLATION, AND
CULVERT OPENINGS GREATER THAN 10' IN WIDTH - USE MINIMUM OF TWO EQUAL WIDTH
PER CULVERT OPENING EQUALS ONE WATER GATE TYPE 3.
ALL NECESSARY INCIDENTALS TO COMPLETRE THE INSTALLATION. TWO OR MORE SECTIONS
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
?
¼
¼
?
? ??
? ?
¼
¼
12-01-15
12-01-15
. .
.
.
TYPICAL PULL POST INSTALLATIONS
X X X
X X X
XX
XX
¡
CROSSROAD
1
¡
x
x
x
x xx
x
xx
x
x
TYPE A CROSSING
x
xx
x
xx
x
x
x
x x
xx
xx
x
x
x
x
x
x
x
x
x
x
x
x
x xx
xx
x
x
x
x
x
x
x
x xx
xx
x
x
x
x
x
x
x
x
xx
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
BARBED WIRE
BARBED WIRE
9'' MAX.
TO FIT VARIOUS CHANNEL SECTIONS.
MAY BE VARIED FOR STEEPER BANKS
NORMAL FLOW; NONE.
1'' MAX.
6''
TO FAN WIRES
GRADE, IF NECESSARY,
TYPE B CROSSING
TO FAN WIRES
GRADE, IF NECESSARY,6'' MAX.
9'' MAX.
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
x x x x x x x x
x
x x
x x x x
x
x x x
x x x x x x
xx
xx
x
xx
x
xx
x
x
x
x
x
x
BARBED WIRE
x x x x x
xx
xx
xx
xx
x x
x x
x
NORMAL FLOW
DIRECTED BY THE ENGINEER.
EXTRA LENGTH POST AS
BARBED WIRE
x x x x x x
x x x x x x
POST
PULL
(TYP)
LINE POST
BRACEFENCING DETAIL
BARBED WIRE
6'' MAX.
x x x x x
x x xxx x
xxxxx
x x x x x x
x
x
6'' MAX.
BARBED WIRE
BARBED WIRE
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
POST
CORNER
ROADWAY
CONNECTION
ABUTMENT
XX
X X
X X
XX
TOP OF RIVER OR CREEK BANK
XX
XX
XX
XX
X
X
X
X
23
3
2
¡
¡ CROSSROAD
PULL POSTS SHALL BE USED AT SHARP BREAKS IN VERTICAL
V
V
V
V
VV
V
V
V
V
V
V
V
V
V V
V
V
V
VVV
V
V
V
V
V
V
V
V
V V
V
V
V
VVV
V
V
V
V
V
V
V
V
V V
V
V
V
VVV
V
V
V
V
V
V
V
V
V V
V
V
V
VVV
V
V
V
V
V
V
V
V
V V
V
V
V
VVV
V
V
V
V
V
V
V
V
V V
V
V
V
VVV
V
V V
V
VV
V
V
VV
VV
VV
VV
V
V
VV
VV
V
V
V
VV
VV
V
V
VV
VV
V
V
V
VV
VV
V
V
VV
VV
V
V
V
VV
VV
V
V
VV
VV
V
V
V
VV
VV
V
V
VV
VV
V
V
V
VV
VV
V
V
VV
VV
V
V
VV
V
V V
V
V
V
V
V
V V
V
V
V
V
V V
V
V
VV
V
V V
V
V
V
V
V V
V
V
VV
V
V V
V
V
V
V
V V
V
V
VV
V
V V
V
V
V
V
V V
V
V
VV
V
V V
V
V
V
V
V V
V
V
VV
V
V V
V
V
V
V
V V
V
V
VV
V
V V
V
VV
V
V
V
V
V
VV
VV
V
V
V
V
V
V
VV
VV
V
V
V
V
VV
V
V
V
V
V
V
VV
VV
V
V
V
V
VV
V
V
V
V
V
V
VV
VV
V
V
V
V
VV
V
V
V
V
V
V
VV
VV
V
V
V
V
VV
V
V
V
V
V
V
VV
VV
V
V
V
V
VV
V
V
V
V
V
V
VV
VV
V
V
V
VV
V
V
V
V V
V
V
V
V
V
V
V
VV
V V
V
V
V
V
V
V
V
V
V
V
VV
V
V
V
V
VV
V
V
V
V
V
V
VV
V
V
V
V
V
V
V
V
V
V
V
VV
V
V
V
VV
V
V
V
V
V
V
V
V
VV
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
VV
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
VV
V
V
V
V
V
V
V
V
V
V
V
V
V
V V
VV
V
V
V
V
V
VV
VV
V
VV
V
V
V
V
VV
V
V
V
V
V
V
V
MAX. 500'
ALIGNMENT AND APPROXIMATELY 500' ON CENTERS.
THE ENGINEER.
AS DIRECTED BY
4'-6'' MIN. EMBEDMENT
MAX. 500'
15'-0'' OR LESS
15'-0'' OR LESS
1'-9''THE ENGINEER.
AS DIRECTED BY
4'-6'' MIN. EMBEDMENT
8'-0'' MAX.
EMBEDMENT
4'-6'' MINIMUM
FENCING DETAILS
FENCE
FENCE
FENCE
FENCE
NORMAL WAY OF HANDLING FENCE WHEN THE HIGHWAY IS OVER THE
PROJECTED, ANGLE FENCE INTO ABUTMENT FROM TOE OF SLOPE AS SHOWN.
½'' EYEBOLT
¾'' DIA. STEEL
CONNECTING ROD
1
2
3
½''x2'' SELF-DRILL ANCHOR AND EYEBOLT ASSEMBLY.
RFW-001-06
BACKWALL FACE
ABUTMENT CONNECTION
ABUTMENT CONNECTION
MORE THAN 1'-6'' FROM FACE
ABUTMENT CONNECTION SHALL
TO BACKWALL
BE NO LESS THAN 6'' NOR4
~ NOTES ~
AS CATTLE CROSSING
FOR BOX CULVERT USED
TYPICAL FENCE INSTALLATION
CROSSROAD AS SHOWN.
BACKWALL PROJECTED, ANGLE FENCE PARALLEL TO THE CENTERLINE OF
WHEN HIGHWAY RIGHT-OF-WAY IS GREATER THAN 15'-0'' FROM THE FACE OF
CROSSROAD AND INTERSECT DETAIL 2 AS SHOWN.
CROSSROAD
HIGHWAY UNDER
CROSSROAD
HIGHWAY OVER
WHEN HIGHWAY RIGHT-OF-WAY IS 15'-0'' OR LESS FROM THE FACE OF BACKWALL
ALL MATERIAL FOR ABUTMENT CONNECTION SHALL BE GALVANIZED.
THE ENGINEER.
AS DIRECTED BY
EXTRA LENGTH POSTS
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
4
5.
12-01-15
12-01-15
. .
.
.
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
45
45 45
LINE POST
LINE POST
OR BETTER (TYP.)
CLASS ''B'' CONCRETE
CAPALL LINE POST AS SHOWN
CLIPS OR FABRIC TIES ON1
OF ROLL FORM POST AND CLIPS
ISOMETRIC EXPLODED VIEW
CLIPS SHALL BE SPRING STEEL ALUMINUM - FINISHED
ANCHOR PLATE
2 GROUND OR
1
2 NOT REQUIRED FOR ROLL FORM POST.
INSTALLED IN ROLL FORM POST
PLAN VIEW OF CLIP
CLIP
ROLL FORM POST
FABRIC
ROLL FORM POST
PLAN VIEW OF
?''
SEE DETAIL ''A''
DETAIL ''A''
ALTERNATE METHODS OF SECURING
VERTICAL STAY WIRE TO THE
HORIZONTAL WIRE OF THE FABRIC.
WELDED
ROLL FORM POST AT 1.40 LBS. PER FOOT (SEE DETAIL)
0.080''
1?''
?"½"
1¼''
END POST 2½" NPS
BRACE 1¼'' NPS
10'-0'' 10'-0''
7'-
0''
3'-
11''
2'-
6''
3'-
0''
1'-6''
2'-0''
2'-6''
1'-6''
2''
2'-
6''
3'-
11''
7'-
0''
3''
3'-
0''
2'-
6''
1'-6''
10'-0''12'-0''
CORNER OR INTERMEDIATE PULL POST 2½" NPS
TYPE 1
WOVEN WIRE FENCE
WOVEN-WIRE FABRIC SHALL BE EITHER ALUMINUM-COATED
STEEL NO. 1047-6-9 OR ZINC-COATED STEEL NO. 1047-6-9.
STUDDED ''T'' POST CONFORMING TO ASTM A702 AT 1.33 LBS. PER FOOT
RFW-005-08
~ NOTES ~
NPS = NOMINAL PIPE SIZE - ASTM F1083 AND F1043 (HEAVY INDUSTRIAL
FENCE) SHALL GOVERN.
3.
4.
5.
- OR -
BID ITEMS AND UNIT TO BID
LFFENCE-WOVEN WIRE TYPE 1
CUYDCONCRETE-CLASS B
ALL FENCE FITTINGS SHALL COMPLY WITH ASTM F626.
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.
12-01-15
12-01-15
. .
.
.
x x x x x x x x x x
x x x x x xx x x x x xx x x
(TYPICAL)
4'' WOOD POST
LINE POST
xxxxxxx
BARBED WIRE
x x x x
(TYPICAL)
8'' WOOD POST
4'' WOOD BRACE
BRACE WIRE
BARBED WIRE
BRACE WIRE
SEE DETAIL ''A''SEE DETAIL ''A''
POST ASSEMBLY
PULL OR END
ASSEMBLY
CORNER POST
1.
2.
WIRE
BARBED
x
ON INTERMEDIATE PULL POST ASSEMBLIES, BRACE WIRES SHALL BE
REQUIRED FOR BOTH DIRECTIONS.
DETAIL ''B''
4''
BRACE
4'' WOOD
''B''
DETAIL
SEE
BARBED WIRE
x
(TYPICAL)
8'' WOOD POST
CONCRETE
CLASS ''B''
ERECTION OF FENCE
DIRECTION OF
BRACE
4'' WOOD
8'' WOOD POST
6'-0''
8'-0''
3''
2''
3'-11''
3'-6''
4'-0''
1'-6''
3''
3'-11''
2''
3'-6''
4'-0''
1'-6''
6'-0''
8'-0'' LONG
WOOD POST
12'-0'' 12'-0''
3''
7'-0''
3'-11''
2''
2'-6''
1''
1'-0''
WOVEN-WIRE FABRIC SHALL BE EITHER ALUMINUM-COATED STEEL NO. 1047-6-9
OR ZINC-COATED STEEL NO. 1047-6-9.
x x x x
BRACE WIRE
DETAIL ''A''
ALTERNATE METHODS OF SECURING
VERTICAL STAY WIRE TO THE
HORIZONTAL WIRE OF THE FABRIC.
WELDED
BRACE WIRE
SEE DETAIL ''B''
CONCRETE
CLASS ''B''
6'-0''
FENCE TYPE 2
WOVEN WIRE
RFW-006-07
~ NOTES ~
BID ITEM AND UNIT TO BID
LFFENCE-WOVEN WIRE TYPE 2
CUYDCONCRETE-CLASS B
STATE HIGHWAY ENGINEER DATE
DATEDIRECTOR DIVISION OF DESIGN
SUBMITTED
APPROVED
DEPARTMENT OF HIGHWAYS
KENTUCKY
STANDARD DRAWING NO.