Page 1: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

SK1N

Technical Manual

Page 2: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

What’s inside

� – Overview p⁰⁵ � – Designing with SK1N p¹⁹ 3 – Installation p³¹ 4 – Design Details p³⁷

5 – Get in Touch p⁵4

Page 3: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural
Page 4: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

4

Page 5: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

SK1N Overview

Page 6: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

6

SK1N is an adaptive building envelope solution suitable for installation on walls and sloping gable roofs as well as onto new and existing buildings. Horizontal SK1N top hats or traditional timber battens are installed over a breathable membrane before each SK1N tile is fixed at preformed holes. All horizontal joints are overlapped, while vertical joints are variable for maximum visual effect. SK1N is a rear ventilated rainscreen cladding system and must be installed onto a waterproofed structural wall or roof.

Designed from Every Angle

Created to flow across any surface, SK1N is a unifying design system that adapts to your architectural vision and the environment it lives within.

Infinite Expression Characterised by genuine versatility and simple installation – SK1N is the perfect solution for both expressive creativity and streamlined efficiency.

Contemporary Yet Enduring Beauty

Developed in Italy – SK1N’s DNA is intimately connected to timeless and iconic European craftsmanship.

Combining the enduring beauty of terracotta with contemporary ceramic techniques and colours, it has a range of imaginative applications, from unique façades to distinctive roof lines – all united in one seamless material expression.

Brickworks Building Products SK1N

Overview

Page 7: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

7

Multilayered Defence Against the Elements

A properly designed and installed rain screen acts as a barrier against water ingress whilst dissipating moisture and condensation out of the building. Each component in the SK1N system is engineered for performance and comprises of:

- the SK1N tiles,

- horizontal battens, either aluminium or timber,

- and a breathable membrane.

The SK1N system can be installed directly onto the frame or with an additional vertical batten creating a vented cavity. This airspace facilitates the removal of excess heat, humidity and moisture through natural convective air movement.

Incident Solar Radiation

Dissipated Solar Radiation to the Outside

Reflected Solar

Radiation

Temp. = 24

Temp. = 0

Air

Temp. = 3 - 4

Internal Temp. = 18

o

o

o

o

Water

C

C

C

C

Dissipated solar radiation to the outside

Page 8: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

8

Brickworks Building Products SK1N

Benefits

Moisture Management

The propriety aluminium SK1N top hat dictates the ideal tile slope and 40 mm overlap. The result is a continuous drainage plane which deflects impeding rain away from critical structural members.

Thermal Efficiency

SK1N has a high thermal mass giving it the ability to absorb and store heat from direct sunlight during the day. This slows down the rate of heat transfer thus moderating internal temperatures and comfort.

Durable

SK1N tiles are classified as exposure grade so that they can be used in all environments, including severe coastal areas with suitable fixings.

Tested Performance

The SK1N system has been rigorously tested by accredited laboratories to ensure that each tile will last. The tiles have been assessed under AS 4459: Methods of sampling and testing ceramic tiles and AS 4455: Masonry units, segmental paves and flags. SK1N is deemed non-combustible under AS 1530.1: Combustibility test for materials and was tested for a strength limit state pressure to AS 4284: Testing of building facades.

Flexibility

TImeless colours, decades of durability, and with a strong horizontal design emphasis, SK1N combines throughful design with extraordinary versatility.

Page 9: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

Here’s what makes SK1N so unique:

Adaptable application SK1N’s dual-aspect functionality makes it ideal for vertical and sloping gable roof

applications.

Bold colour for life Offering seven highly appealing colours, SK1N’s original palette of fired clay tiles is inspired by nature.

Location flexibilityOffers outstanding design potential for urban or rural projects.

Bespoke finishesEach SK1N tile is truly unique due to diversity of colour and texture.

Non-combustibleSK1N tiles are made from fired clay so they are non combustible.

NaturalMade from natural materials, SK1N emits no VOCs.

Sustainably thoughtfulSK1N is entirely recyclable and reusable.

Rain screenRear ventilated facade offers great thermal benefits.

Easy installationSK1N is fast, secure, and genuinely uncomplicated to install.

Enduring qualityWith a 100 year warranty, SK1N tiles are colourfast, durable and low maintenance.

9

Page 10: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

10

SK1N System Overview

Figure 2a - SK1N Top Hat Figure 2b - SK1N Starter Trim

450 450 450 450

170

170

170

170

170

100

Timber or steel frame

SK1N tile

SK1N top hat

Breathablemembrane

SK1N starter trim

Brickworks Building Products SK1N

System Overview

System Overview

Page 11: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

11

Sk1N System Properties

L Shape U Shape

Dimensions 500 x 210 x 35 mm 500 x 210 x 35 mm

Tiles/m² 11.8 pcs/m² 11.8 pcs/m²

Weight per tile 3.2 kg 3.8 kg

Weight/m² (Inc SK1N top hat)

41.2 kg

48.3 kg

Weight/m² (Inc 38 x 38 mm F5 timber batten)

43.1 kg 50.2 kg

Tile overlap 40 mm 40 mm

Horizontal batten distance 170 mm 170 mm

SK1N System Material List

Component Material List

Tiles Fired clay

SK1N starter trim Aluminium grade 6060-T66

SK1N top hat Aluminium grade 6060-T66

Breathable membrane Spunbonded polypropylene material or equivalent grade

Timber batten and starter Minimum F5 (supplied by builder as per details)

Page 12: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

12

Brickworks Building Products SK1N

Components

The L profile allows the product to sit flatter across the facade and results in subtle lines running across the facade.

When using the U profile, the product's nose sits more pronounced and creates greater emphasis on horizontal lines running across the facade.

U Profile L Profile

SK1N tiles are extruded from traditional clay and fired at extreme temperatures providing a low maintenance cladding which is non-combustible, durable and colour fast. The end result is a natural aesthetic, bound to outlast the harsh weathering of any environment.

Page 13: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

13

Dimensions of a SK1N Tile

Property Specification Standard

Dimensions (L x H x T) 1 500 x 210 x 35mm AS 4459.2

Water absorption < 12 % AS 4459.3

Bulk density 2.5 g/cm³ AS 4459.3

Modulus of rupture > 7 MPa AS 4459.4

Mean coefficient of restitution 0.55 AS 4459.5

Linear thermal expansion 8.21 x 10 -6/ oC AS 4459.8

Modulus of elasticity 3.1 MPa AS 4459.14

Durability classification² Exposure AS/NZS 4455.1

Moisture expansion 0.56 AS 4456.11

210

30 30

6

75

500

75 35 35100 150 100

Tile Properties

1. SK1N terracotta tiles are formed from natural raw materials and dimensions may vary +/- 5mm

2. SK1N tiles are suitable for coastal regions with compatible fixings (refer to Table 8) and should be iinstalled with adequate clearance from the ground.

18

17

Page 14: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

14

Brickworks Building Products SK1N

Overview Colours

Alento –

Dappled sunlight on silver sands was the inspiration for the tactile and relaxing tones embodied in each tile. Perfect for beachside projects or at home anywhere.

Livenza –

Elegant and gentle, this tranquil grey lifts solid forms to give the impression of gently floating planes.

Savio

A subtle grey surface wash effect gives this classic terracotta coloured tile a delightfully softer and subtly variable tone.

Please Note:

The product images in this manual give a general indication of colour for your

preliminary selection. We recommend current product samples to be viewed

before making your final selection. All SK1N colours will feature natural variation

between tiles in the blend. Crafted from natural clay which is kiln fired, there will

be some variation between product batches which should be understood when

ordering the product.

Page 15: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

15

Tesino

Vibrant and welcoming, this classic terracotta orange colour creates a delicate colour plane.

Potenza

A warm, inviting, and comforting classical terracotta tone that originated in Sienna, Italy during the Renaissance.

Piave

A rich, earthy charcoal tone which works across cool and warm colour schemes to create a subtly variegated impression.

Chienti

Chienti’s light brown tone is reminiscent of aged natural wood, with a highly appealing and timeless, natural feel.

Tile Light Reflectance Values (LRV) Solar Absorption (SA)

Alento 50.9 25.1

Livenza 29.5 70.4

Potenza 13.8 62.0

Piave 7.0 85.5

Savio 22.5 72.1

Chienti 11.6 79.0

Tesino 16.9 58.0

Light Reflectance Values and Solar Absorption of SK1N Products

Page 16: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

16

Brickworks Building Products SK1N

Overview Batten Options A proprietary aluminium starter trim and top hat provide the basis for the SK1N system and is suitable for both wall and roof installations. Traditional 38 x 38 mm timber battens can also be used.

Material Nominal Length (mm)

SK1N top hat EN AW 6060-T66 3000

SK1N starter trim EN AW 6060-T66 3000

Timber batten F5 or above -

Timber starter F5 or above -

Batten Options

60

21.5

80°

2.3

3019.6

40

104°

93°

SK1N Top Hat SK1N Starter Trim

SK1N System Overview

Figure 2a - SK1N Top Hat Figure 2b - SK1N Starter Trim

450 450 450 450

170

170

170

170

170

100

Timber or steel frame

SK1N tile

SK1N top hat

Breathablemembrane

SK1N starter trim

SK1N System Overview

Figure 2a - SK1N Top Hat Figure 2b - SK1N Starter Trim

450 450 450 450

170

170

170

170

170

100

Timber or steel frame

SK1N tile

SK1N top hat

Breathablemembrane

SK1N starter trim1.5

2.0

Page 17: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

17

SK1N Starter Trim

Breathable Membrane

Moisture management and reducing condensation build up is critical in maintaining building longevity and comfort. A suitable water control membrane should be installed under SK1N which prevents the ingress of liquid water whilst allowing for water vapour to escape. This is especially critical in humid climate zones and must comply with AS/NZS 4200.2 Pliable building membranes and underlays – Installation as well as any NCC requirements.

Membrane specifications for wall installations of SK1N are detailed in table opposite. This may be substituted with another membrane with equivalent or better properties.

Roll dimensions 1.5 m x 50 m

Weight of complete roll 7.5 kg

Thickness 0.5 mm

Weight 100/m2

Resistance to water penetration Pass

Water vapour permeability 7.5 μg/Ns

Vapour resistance 0.13 MNs/g

Burst strength, wet dry 294 N

Duty Light

Flammability index Low

Air permeability Air permeable

Allowable UV exposure prior to installation of cladding

2 months

Tensile strengthMD 3.8 kN/m

CD 3.1 kN/m

Membrane Properties

Page 18: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

18

Page 19: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

2

Designing With SK1N

Page 20: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

20

Brickworks Building Products SK1N

Designing with SK1N

The installation requirements of the SK1N system are influenced by the wind loads and must comply with either AS 4055: Wind loads for housing or AS/NZS 1170.2: Structural design actions - Part 2: Wind actions

Brickworks Building Products consulted Rickard Engineering to provide the following guide for installing the SK1N system in respect to terrain category, building height and wind region. Please note that further engineering may be required to

consider topography, shielding and building orientation as well as any state and/or local council requirements.

Region A1

Region A2

Region A3

Region A4

Region A5

Region C

Region D Region B

Hobart

Melbourne

AdelaideSydney

Canberra

Perth

Brisbane

Darwin

Alice Springs

Tropical Cyclones50KM

Intermediate100KM

Normal

Region BIntermediate

100KM

Region CTropical Cyclones

50KM

Severe Tropical Cyclones

Normal

Normal

Normal

Normal

Toowoomba

Coffs Harbour

Bundaberg

Mackay

Cairns

Cooktown

Townsville

Katherine

Broome

Kalgoorlie

Albany

Launceston

Region A3Normal

Weipa

Atherton

Emerald

Grafton

Derby

Portheadland

Adelaide River

30O

25O

20O

Wind Region

Dunbar

McDonnel

Moreton

Regions are marked with the letters A (A1-A5), B, C and D.

Coastal region boundaries are smooth lines in from coastline by

50, 100, 150 and 200km. Islands within 50km of the coast are

designed in the same regions as the adjacent coast.

Step 1 - Determine Wind Region

Page 21: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

21

Step 2 - Terrain Category Region Definitions as per 1170.2:2011 Clause 4.2.1

Terrain, over which the approach wind flows towards a structure, shall be assessed on the basis of the following category descriptions:

1. Terrain Category 1 (TC1) Very exposed open terrain with few or no obstructions and enclosed, limited-sized water surfaces at serviceability and ultimate wind speeds in all wind regions, e.g. flat, treeless, poorly grassed plains; rivers, canals and lakes; and enclosed bays extending less than 10 km in the wind direction.

2. Terrain Category 1.5 (TC1.5) Open water surfaces subjected to shoaling waves at serviceability and ultimate wind speeds in all wind regions, e.g. near-shore ocean water; large unenclosed bays on seas

and oceans; lakes; an denclosed bays extending greater than 10 km in the wind direction. The terrain-height multipliers for this terrain category shall be obtained by linear interpolation between the values for TC1 and TC2 in Table 4.1. 3. Terrain Category 2 (TC2) Open terrain, including grassland, with well-scattered obstructions having heights generally from 1.5 m to 5 m, with no more than two obstructions per hectare, e.g. farmland and cleared subdivisions with isolated trees and uncut grass.

4. Terrain Category 2.5 (TC2.5) Terrain with a few trees or isolated obstructions. This category is intermediate between TC2 and TC3 and represents the terrain in developing outer urban areas with scattered houses, or large

acreage developments with fewer than ten buildings per hectare. The terrain-height multipliers for this terrain category shall be obtained by linear interpolation between the values for TC2 and TC3 in Table 4.1.

5. Terrain Category 3 (TC3) Terrain with numerous closely spaced obstructions having heights generally from 3 m to 10 m. The minimum density of obstructions shall be at least the equivalent of 10 house-size obstructions per hectare, e.g. suburban housing, light industrial estates or dense forests.

6. Terrain Category 4 (TC4) Terrain with numerous large, high (10 m to 30 m tall) and closely-spaced constructions, such as large city centres and well-developed industrial complexes.

Page 22: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

22

Step 3 - Determine Maximum Height of Installation

Brickworks Building Products SK1N

Designing with SK1N

Max Height Installation Diagram

Batten Spacing Fixing Screw

? ?

WaterSpecial Case – Water Side

Locations or Hills with Slopes > 11Contact structural engineer for further advice

Typical Caseo

Page 23: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

23

Limiting Height (m)

Terrain CategoryWind Pressures (kPa)

Region A Region B Region C

7

4 1.3 2.1 3.2

3 1.6 2.6 3.9

2.5 1.9 3 4.4

2 2.1 3.4 5

1.5 2.4 3.9 5.8

1 2.8 4.4 6.5

15

4 1.3 2.1 3.2

3 1.9 3 4.5

2.5 2.2 3.6 5.3

2 2.6 4.2 6.2

1.5 2.9 4.6 6.9

1 3.2 5.1 7.6

25

4 1.4 2.2 3.2

3 2.1 3.4 5.1

2.5 2.5 4 5.8

2 2.8 4.5 6.7

1.5 3.1 5 7.3

1 3.4 5.4 8

Step 4 - Determine Maximum Wind Pressure for Corresponding Region, Terrain Category and Maximum Building Height

Maximum Design Wind Pressure

Page 24: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

24

Notes:

1. For projects within coastal regions or areas subject to salt spray, it is recommended to utilise SS 316 fixings.

Brickworks Building Products SK1N

Designing with SK1N

Step 5 - Check SK1N Assembly

Recommended Fixing for Tile to Batten

Tile Profile Batten Type Ultimate Windload

(kPa)

Maximum Stud Spacing

(mm)

Size Type Grade1

U Shape

SK1N top hat 4.08 600 #10 x 40mmCountersunk head screw

SS 304

F5 Timber

F11 and above

4.60

4.60

450

600#10 x 50mm

Type 17 Countersunk head

External Grade or SS 304

L Shape

SK1N top hat3.19

1.80

450

600

#10 x 40mm

#12 x 40mm

Countersunk head screw

SS 304

F5 Timber

F11 and above

3.40

3.60

450

600#10 x 50 mm

Type 17 Countersunk head

External Grade or SS 304

L Shape 4 fixings

SK1N top hat4.08

2.33

450

600

#10 x 40mm

#10 x 40mm

Countersunk head screw

SS 304

F5 Timber

F11 and above

5.14

6.50

450

600#10 x 50 mm

Type 17 Countersunk head

External Grade or SS 304

Page 25: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

25

650

600

550

500

450

400

Span

(mm

)

Ultimate Windload (kPa)

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4

650

600

550

500

450

400

Span

(mm

)

Ultimate Windload (kPa)

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.45.2

Tile Profile Batten Type Ultimate Windload

(kPa)

Maximum Stud Spacing

(mm)

Size Type Grade1

U Shape

SK1N top hat 4.08 600 #10 x 40mmCountersunk head screw

SS 304

F5 Timber

F11 and above

4.60

4.60

450

600#10 x 50mm

Type 17 Countersunk head

External Grade or SS 304

L Shape

SK1N top hat3.19

1.80

450

600

#10 x 40mm

#12 x 40mm

Countersunk head screw

SS 304

F5 Timber

F11 and above

3.40

3.60

450

600#10 x 50 mm

Type 17 Countersunk head

External Grade or SS 304

L Shape 4 fixings

SK1N top hat4.08

2.33

450

600

#10 x 40mm

#10 x 40mm

Countersunk head screw

SS 304

F5 Timber

F11 and above

5.14

6.50

450

600#10 x 50 mm

Type 17 Countersunk head

External Grade or SS 304

Minimum Span for SK1N Aluminium Top Hat

Minimum Span for Timber Battens

U Shape AI Top Hat

L Shape AI Top Hat with Four Fixings

L Shape AI Top Hat

U Shape F5/F11 Timber

L Shape F11 Timber

L Shape with Four Fixings

L Shape F5 Timber

Page 26: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

26

Step 5 - Check SK1N Assembly

Screw Gauge Recommendation for Battens to Studs

Notes:

1. Embedment length should be ≥ 30 mm for 38 x 38 mm timber battens. 2. Fixings must be suitable for the corresponding substrates as well as the appropriate level of durability required for the intended project

Batten Substrate Size Type Grade2

SK1N Top Hat

Timber1 #12Type 17 wafer

or button head screw

SS 304

Steel #14Wafer or

button head metal screw

SS 304

Timber Batten

Timber1 #14Type 17 wafer

or button head screw

External grade or SS304

Steel #14 Countersunk metal screw External grade or SS304

Brickworks Building Products SK1N

Designing with SK1N

Page 27: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

27

Page 28: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

28

Brickworks Building Products SK1N

Safe Working Instructions

Crystalline silica dust can be liberated from SK1N tiles and repeated inhalation has been associated with impaired lung function. Safe work procedures should be taken to reduce inhalation of silica dust which include:

- The use of a wet saw or dust extraction equipment when reworking tiles

- Wearing appropriate personal protective equipment such as dust mask and safety goggles

- Ensuring adequate ventilation

Recommended Safety Equipment

Face Masks P1 or P2 type

approved to the relevant

Australian Standards.

Safety Googles approved

to the relevant Australian

Standards.

Hearing Protection

approved to the relevant

Australian Standards.

Clean up, wet down

or vacuum.

Dispose of

contaminent

of dust.

Page 29: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

27

Page 30: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

30

Page 31: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

3

SK1N Installation

Page 32: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

32

Walling Installation The SK1N system is suitable for installation on building walls up to 25 metres and can be installed over traditional stud configurations. Proprietary aluminium top hats or timber battens are installed over a waterproof membrane before tiles are fixed with two screws.

Brickworks Building Products SK1N

Walling Installation

1. SK1N may be specified for timber or steel framed structures.

2. Install a suitable waterproof membrane underneath all areas where SK1N will be clad.

a. Wall openings such as doors, window edges and penetrations should be flashed appropriately to prevent moisture ingress into the building frame.

b. The membrane should be installed in accordance with AS/NZS 4200.2:2017 Pliable Building Membranes and Underlays and/or as per the specifiers installation instructions. A compliant installation can include:

i. A minimum of 150 mm overlap between membrane joins and wall corners

ii. All overlaps and punctures to be taped or sealed and, where possible, align with a wall stud

iii. Minimum fixing distances with mechanical fasteners or adhesive.

SK1N is suitable for timber and steel framed structures.

Page 33: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

33

3. Install starter trim at appropriate height to ensure clearance from ground slab and fixed at every stud.

4. Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural support for the SK1N tiles.

a. A 170 mm vertical spacings between the battens allow for a 40 mm tile overlap concealing screw locations.

5. Hang tile onto the batten and fasten at a minimum two of four preformed fixing holes.

a. Note that tiles are a fired clay natural product and thus variations in edge straightness will be present.

b. Ensure holes are sufficiently countersunk and large enough for screws to pass cleanly.

c. It is good practice to partially fix the tile at two locations then tighten evenly just until the tile is firmly gripped.

d. Over tightening will cause uneven installation of tiles and can lead to fractured tiles.

Max Height Installation Diagram

Batten Spacing Fixing Screw

? ?

WaterSpecial Case – Water Side

Locations or Hills with Slopes > 11Contact structural engineer for further advice

Typical Caseo

Max Height Installation Diagram

Batten Spacing Fixing Screw

? ?

WaterSpecial Case – Water Side

Locations or Hills with Slopes > 11Contact structural engineer for further advice

Typical Caseo

SK1N tile

Batten

Page 34: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

34

Roofing Installation SK1N is suitable for gable and skillion roof applications only and must be installed onto a waterproof metal or marine ply underlay. For gable roofs, a metal dry verge should be used. Roof spacings must be adequate for the wind conditions and loads subjected to the SK1N installation. It should also be in accordance with AS 1562.1:2018 Design and installation of sheet roof and wall cladding.

Brickworks Building Products SK1N

Roofing Installation

1. Install all necessary guttering, fascia boards and guard rails

2. A metal or marine ply roofing underlay is to be installed to provide weather tightness to the structure

For a metal underlay

a Supporting top hats are fixed to the roof structure before installing the metal roof sheeting.

For ply underlay

b Sheath roofing structure with marine ply and ensure structure is continuously joined at rafters or trusses

c Fix 30 x 10 mm counter battens on top of the ply layer to simulate typical 600 mm spaced rafters

d Install a waterproof membrane, compliant with AS 4654.1, on top of the counter battens

Page 35: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

35

3. Install starting tilt batten to allow for a 50 mm tile overhang for the first course

4. Fix horizontal battens, either 38 x 38 mm timber battens or SK1N top hat at 170 mm centres on top of the water proof underlay

5. Screw each tile with two 10 gauge type 17 counter sunk head screws into the central preformed holes

a. SK1N tiles are installed with a 40 mm overlap and are recommended to be side laid in stretcher bond pattern working up and across the roof minimising the traffic on the tiles and potential breakage

b. For durability, fixing screws are required to be stainless steel grade 304

c. The embedment length of the screw should be ≥ 30 mm into the 38 x 38 mm batten

Page 36: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

36

Page 37: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

4

Design Details

Page 38: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

38

SK1N System Overview

Figure 2a - SK1N Top Hat Figure 2b - SK1N Starter Trim

450 450 450 450

170

170

170

170

170

100

Timber or steel frame

SK1N tile

SK1N top hat

Breathablemembrane

SK1N starter trim

General Walling

Front View of SK1N System

Brickworks Building Products SK1N

Design Details

Page 39: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

39

Plan View of SK1N System

Figure 3 - Front View of SK1N System

SK1N top hat

Insulation

Fixing

SK1N tile

Framing

902578.2

SK1N tile

SK1N top hat

Breathable membrane

Insulation

25mm Aluminiumvertical batten

Fixing

Timber frame or steel frame

902495.2

SK1N tile

Breathable membrane

Insulation

24mm Steelfurring channel

Fixing

Timber frame or steel frame

Cavity options

38 × 38 timber batten

Breathable membrane

Page 40: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

40

Brickworks Building Products SK1N

Design Details

U Profile with SK1N Top HatsU Profile with Timber Battens

Section View of U Shape on

Timber Battens or SK1N Top Hats

Fixing

38 x 38Timber batten

70 x 35 Timber batten

Breathable membrane

SK1N Tile

SK1Nstarting trim

SK1N top hat

Fixing

38 x 38Timber batten

50 x 25 Timber batten

Breathable membrane

SK1N Tile

120

170

100

170

100

170

SK1N Tile

SK1N starting trim

100

170

Fixing

38 x 38Timber batten

70 x 35 Timber batten

Breathable membrane

SK1N Tile

SK1Nstarting trim

SK1N top hat

Fixing

38 x 38Timber batten

50 x 25 Timber batten

Breathable membrane

SK1N Tile

120

170

100

170

100

170

SK1N Tile

SK1N starting trim

100

170

Page 41: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

41

Section View of L Shape on

Timber Battens or SK1N Top Hats

L Profile with Timber Battens L Profile with SK1N Top Hats

Fixing

38 x 38Timber batten

70 x 35 Timber batten

Breathable membrane

SK1N Tile

SK1Nstarting trim

SK1N top hat

Fixing

38 x 38Timber batten

50 x 25 Timber batten

Breathable membrane

SK1N Tile

120

170

100

170

100

170

SK1N Tile

SK1N starting trim

100

170

Fixing

38 x 38Timber batten

70 x 35 Timber batten

Breathable membrane

SK1N Tile

SK1Nstarting trim

SK1N top hat

Fixing

38 x 38Timber batten

50 x 25 Timber batten

Breathable membrane

SK1N Tile

120

170

100

170

100

170

SK1N Tile

SK1N starting trim

100

170

Page 42: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

42

SK1N top hat

SK1N tile

Timber frame or steel frame

25mm aluminiumvertical batten

Breathable membrane

Insulation

Fixing

25 9078.2902495.2

38 x 38 timber batten

SK1N tile

Timber frame or steel frame

24mm steelfurring channel

Breathable membrane

Insulation

Fixing

Cavity Options

Brickworks Building Products SK1N

Design Details

Cavity Fix with SK1N Top Hats Cavity Fix with Timber Battens

Page 43: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

43

External Corner B

SK1N tile

Fixing

Breathable membrane

Insulation

SK1N top hat

External corner trim

Corner framing detail

External Corner with Trim

Page 44: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

44

Brickworks Building Products SK1N

Design Details

External Corner with Mitred Tiles

External Corner A

SK1N tile

Fixing

Breathable membrane

Corner framing detail

Insulation

SK1N top hat

Page 45: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

45

Cutting guide for

external corner tiles

Figure 8 - L Shape External Corner Assembly

Figure 9 - Corner Detail Cutting Guide for L Shape

500477

477

250

500

227

250227

45

o

45

o

500

457

250

82°84°

40

L Shape External Corner Assembly Corner Detail Cutting Guide for L Shape

477

500

231

250

210

40

82 o

84 o

8o

Figure 8 - L Shape External Corner Assembly

Figure 9 - Corner Detail Cutting Guide for L Shape

500477

477

250

500

227

250227

45

o

45

o

500456.7

456.7

250

500

206.9

251206.9

45o

45

o

Figure 10 - U Shape External Corner Assembly

Figure 11 - Corner Detail Cutting Guide for U Shape

500

250

210

477

78°82°

40

U Shape External Corner Assembly Corner Detail Cutting Guide for U Shape

457

500

250

78 o

82 o

500456.7

456.7

250

500

206.9

251206.9

45o

45

o

Figure 10 - U Shape External Corner Assembly

Figure 11 - Corner Detail Cutting Guide for U Shape

Page 46: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

46

Brickworks Building Products SK1N

Design Details

Internal Corner

Internal Corner

Fixing

SK1N tile

58 × 58 internal corner flashing

Breathable membrane

Internal corner framing

Insulation

SK1N top hat

Eave

Sealant and backing rod

Roof/Eave Junction

Internal Corner

Fixing

SK1N tile

58 × 58 internal corner flashing

Breathable membrane

Internal corner framing

Insulation

SK1N top hat

Eave

Sealant and backing rod

Page 47: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

47

Roof with Box Gutter Detail

38 × 38 timber batten

Waterproof roof structure

Rafter

SK1N top hat

SK1N tile

Waterproof membrane

Page 48: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

48

Brickworks Building Products SK1N

Design Details

170

170

170

Barge board End rafter Top hat

Continuous concealedgutter flashing

SK1N tile

Tile batten fixed to metal sheetunderlay at 300mm cutsMetal roof sheeting underlay

RafterFascia board

Top hat

Metal roof sheeting underlay

Metal cover plate

Tilt batten

38 × 38mm Tile battens screwed to metal sheet underlay at 300mm ctrs

SK1N tile

SK1N Roof with Metal Underlay

170

170

170

RafterFascia board

Top hat

Metal roof sheeting underlay

Metal cover plate

Tilt batten

38 × 38mm Tile battens screwed to metal sheet underlay at 300mm ctrs

SK1N tile

170

170

170

Barge board End rafter Top hat

Continuous concealedgutter flashing

SK1N tile

Tile batten fixed to metal sheetunderlay at 300mm cutsMetal roof sheeting underlay

RafterFascia board

Top hat

Metal roof sheeting underlay

Metal cover plate

Tilt batten

38 × 38mm Tile battens screwed to metal sheet underlay at 300mm ctrs

SK1N tile

SK1N Roof with Metal Underlay

170

170

170

RafterFascia board

Top hat

Metal roof sheeting underlay

Metal cover plate

Tilt batten

38 × 38mm Tile battens screwed to metal sheet underlay at 300mm ctrs

SK1N tile

Page 49: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

49

170

170

170

Barge board End rafter Top hat

Continuous concealedgutter flashing

SK1N tile

Tile batten fixed to metal sheetunderlay at 300mm cutsMetal roof sheeting underlay

RafterFascia board

Top hat

Metal roof sheeting underlay

Metal cover plate

Tilt batten

38 × 38mm Tile battens screwed to metal sheet underlay at 300mm ctrs

SK1N tile

SK1N Roof with Metal Underlay

170

170

170

RafterFascia board

Top hat

Metal roof sheeting underlay

Metal cover plate

Tilt batten

38 × 38mm Tile battens screwed to metal sheet underlay at 300mm ctrs

SK1N tile

SK1N Roof with Metal Underlay

Page 50: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

50

Brickworks Building Products SK1N

Design Details

Barge boardEnd rafter Marine ply joined at rafter

Continuous concealedgutter flashing

SK1N tile

Tile batten

30 × 10mm Counter battern

Waterproof membrane

170

170

170

RafterFascia board

Ply fillet

Marine ply joined at rafter

30 × 10mm Counter batten

Waterproof membrane

38 × 38mm Timber batten

SK1N tile

170

170

170

RafterFascia board

Ply fillet

Marine ply joined at rafter

30 × 10mm Counter batten

Waterproof membrane

38 × 38mm Timber batten

SK1N tile

Ply Underlay

Barge boardEnd rafter Marine ply joined at rafter

Continuous concealedgutter flashing

SK1N tile

Tile batten

30 × 10mm Counter battern

Waterproof membrane

170

170

170

RafterFascia board

Ply fillet

Marine ply joined at rafter

30 × 10mm Counter batten

Waterproof membrane

38 × 38mm Timber batten

SK1N tile

170

170

170

RafterFascia board

Ply fillet

Marine ply joined at rafter

30 × 10mm Counter batten

Waterproof membrane

38 × 38mm Timber batten

SK1N tile

Ply Underlay

Page 51: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

51

SK1N Roof with Ply Underlay

Barge boardEnd rafter Marine ply joined at rafter

Continuous concealedgutter flashing

SK1N tile

Tile batten

30 × 10mm Counter battern

Waterproof membrane

170

170

170

RafterFascia board

Ply fillet

Marine ply joined at rafter

30 × 10mm Counter batten

Waterproof membrane

38 × 38mm Timber batten

SK1N tile

170

170

170

RafterFascia board

Ply fillet

Marine ply joined at rafter

30 × 10mm Counter batten

Waterproof membrane

38 × 38mm Timber batten

SK1N tile

Ply Underlay

Page 52: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

52

Backed by Brickworks Local expertise. Global quality. Brickworks Building Products is one of Australia’s biggest building material producers. With heritage going all the way back to one of Australia’s founding brick producers, we’re proud of our reputation for design, innovation and sustainability.

AUSTRALIA

EXCLUSIVE DISTRIBUTOR

NORTH AMERICA

Page 53: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural
Page 54: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

52

Get in touch–For more information, advice and samples get in touchwith the team.

Page 55: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural

55

Design Centres

Follow Us

The product images shown in this brochure give a general indication of product colour for your preliminary selection. Austral Masonry recommends all customers see actual product samples at a selection centre prior to making final selections. 1. Stock colours. Colours other than stock colours are made to order. Contact your nearest Austral Masonry office for your area’s stock colours. A surcharge applies to orders less than the set minimum quantity. 2. Colour and texture variation. The supply of raw materials can vary over time. In addition, variation can occur between product types and production batches. 3. We reserve the right to change the details in this publication without notice. 4. For a full set of Terms & Conditions of Sale please contact your nearest Austral Masonry sales office. 5. Important Notice. Please consult with your local council for design regulations prior to the construction of your wall. Councils in general require those walls over 0.5m in height and/or where there is loading such as a car or house near the wall be designed and certified by a suitably qualified engineer. 6. Max wall heights disclaimer. The gravity wall heights are maximum heights calculated in accordance with CMAA MA-53 Appendix D guidelines and a qualified engineer should confirm the suitability of the product for each application. As such, due consideration must be given to but not limited to: Cohesion. Dry backfill, no ingress of any water into the soil behind the retaining wall. All retaining walls are designed for zero surcharge unless noted otherwise. These walls are intended for structure Classification A walls only as defined in AS4678 Earth Retaining Structures as being where failure would result in minimal damage and/or loss of access.

SydneyTel. 02 9611 4200 2 Barrack Street Sydney NSW 2000

MelbourneTel. 03 8621 7777 Ground Floor 367 Collins Street Melbourne VIC 3000

BrisbaneTel. 07 3634 5604 27 James Street Fortitude Valley QLD 4006

AdelaideTel. 08 8443 2222 Ground Floor 70 Hindmarsh Square Adelaide SA 5000

PerthTel. 08 6332 5800 67 King Street Perth WA 6000

HobartTel. 03 6212 9120 9 Franklin Wharf Hobart TAS 7000

Page 56: SK1Nbbp.style/PUBLIC/products/technical-manual/australbricks/...Fix horizontal battens, either timber or aluminium top hats, top and bottom at every stud to ensure adequate structural