zte cabinets

41
09/06/202 2 Knowledge sharing sessions ZXG10-BTSV2.0 ZXG10-BS30(V1.2) ZXG10-M8206 ZXG10-BS21 (V2.0) ZXG10-OB06 ZTE CABINETS

Upload: benaiad-abdellah

Post on 03-Jun-2015

5.360 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

ZXG10-BS30(V1.2)

ZXG10-M8206

ZXG10-BS21 (V2.0)

ZXG10-OB06

ZTE CABINETS

Page 2: Zte cabinets

BTS V 2.0 BS21(V2.0) OB06 M8206 BS30(V1.2)ZTE Network

ZTE CABINETS

1161

69 43 31 27

12/04/2023

ZTE CABINETS

Page 3: Zte cabinets

Antenna feeder processor

RF Unit

Base Band Processor

Controller & M

aintenance M

odule

BSC

Power Supply Module

Um interface

System clock

RF signal

Modelated base band signal

System clock

Control signal

Demodelated RF signal

Data link

Abis

WORKING PRINCIPLE

220V

12/04/2023

Heat exchanger

ZTE CABINETS

Page 4: Zte cabinets

Antenna feeder processor

RF Unit

Base Band Processor

Controller & M

aintenance M

odule

BSC

Power Supply Module

Um interface

System clock

RF signal

Modelated base band signal

System clock

Control signal

Demodelated RF signal

Data link

Abis

WORKING PRINCIPLE

220V

12/04/2023

Heat exchanger

ZTE CABINETS

Downlink: The BTS receives data from BSC, including voice and signaling data. The transmission unit sends signaling data to the operation & maintenance unit for processing. The voice data are then sent to baseband processor for processing of rate conversion, encryption

and interleaving. Data are then sent to RF unit for modulation to high-frequency signals. Finally, data are then transmitted through the antenna feeder processor.

Page 5: Zte cabinets

Antenna feeder processor

RF Unit

Base Band Processor

Controller & M

aintenance M

odule

BSC

Power Supply Module

Um interface

System clock

RF signal

Modelated base band signal

System clock

Control signal

Demodelated RF signal

Data link

Abis

WORKING PRINCIPLE

220V

12/04/2023

Heat exchanger

ZTE CABINETS

Uplink: The antenna feeder processor receives the RF signals from the MS. It then sends these signals to

the RF unit to convert into digital signals. The signals are then transmitted to baseband processor for rate signals conversion, decryption

and de-interleaving. After conversion to the code pattern, suitable for long-distance transmission, the signals are sent

to the BSC through the Abis interface.

Page 6: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

ZXG10-BS30(V1.2)

ZXG10-M8206

ZXG10-BS21 (V2.0)

ZXG10-OB06

ZTE CABINETS

Page 7: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

12/04/2023

ZTE CABINETS

Page 8: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

The CMM (Control & Maintenance Module) performs the following functions:Abis interface processingBTS operation & maintenanceClock synchronization and generationCollection of internal/external alarmsFan management and the active/standby

function

12/04/2023

ZTE CABINETS

Page 9: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

The TRM/ETRM ( Transceiver Module ) performs the following functions:Runs and Controls radio channels in

GSM systemSends/receives radio channel dataModulates/demodulates baseband

signals on the radio carrier frequencySends/receives radio carrier signals and

collects alarms of the fans and AEMs.

12/04/2023

ZTE CABINETS

Page 10: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

The BTM (Backplane Transmission Module) contains Motherboard of CMM (MCMM), Motherboard of Transceiver Module (MTRM).

12/04/2023

ZTE CABINETS

Page 11: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

AEM (Antenna Equipment Module) provides the following functions:Combines the transmit signals of multiple carriers. Provides bidirectional signal channels from

the BTS to the antenna for the transmitting band and from the antenna to the BTS for the receiving band.

Gives an alarm when the VSWR of the antenna port deteriorates.

Suppresses the interference out of the working band and spurious emission.

Flexibly configures carriers. Implements diversity receiving.

12/04/2023

ZTE CABINETS

Page 12: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

The PDM (Power Distribution Module) performs the following functions: Distributes -48 V DC power to all the

modules Provides overload protection Stabilizes the input power

12/04/2023

ZTE CABINETS

Page 13: Zte cabinets

AEM

BSC CMM

PDM

FCM

BTM

TR/ETRM3

TR/ETRM2

TR/ETRM1

Abis Um

External communication bus

MMI

Hardware Structure

BTSV2.0

The FCM (Fan Control Module) monitors and collects the temperature in the carrier shelves and dissipates heat through fans.

12/04/2023

ZTE CABINETS

Page 14: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

ZXG10-M8206

ZXG10-BS21 (V2.0)

ZXG10-OB06

ZTE CABINETS

ZXG10-BS30(V1.2)

Page 15: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

ZTE CABINETS

Page 16: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

The transceiver for station module (TSM), consist of controller & maintenance module (CMM), transceiver module (TRM) and backboard connection unit (BCU)

ZTE CABINETS

Page 17: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

The DPM (Duplexer Module ) provides bi-directional channels for signals between the BTS and the antenna, suppresses the interference and spurious radiation beyond the working band, and implements SWR alarm detection at the antenna port.

ZTE CABINETS

Page 18: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

CMM (Controller & Maintenance Module ) provides such functions as Abis interface processing, BS operation & maintenance, clock synchronization and generation, and internal/external alarm collection and processing. CMM consists of a control O&M board.

ZTE CABINETS

Page 19: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

The ZXG10 BS30 supports built-in SDH transmission equipment, which is implemented by configuring STM.The STM is the T150 researched and manufactured by ZTE. T150 provides the ZXG10 BS30 with 155 Mbits/s SDH interface, providing diversified BS transmission interfaces.

ZTE CABINETS

Page 20: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

PWM (Power Supply Module ) provides rectification, filtering and voltage stabilizing protection of 220 VAC (single-phase three-lines), supplies 220 VAC for HTM, TSM, STM and internal/external fans, and provides 220 VAC input over/under-voltage dry contact alarm.

ZTE CABINETS

Page 21: Zte cabinets

TSM

Backplane

CMM

STM

TRM

DPM

HTMPWMInternal FAN

E1

RX

Hardware Structure

BS30(V1.2)

12/04/2023

LNA

Dup

Receiving filter

Optical interface

HW signal

TX

AC 220V

HTM (Heater Module) consists of a heater and a fan. It serves to control internal temperature and ensure the normal operation of the equipment.

ZTE CABINETS

Page 22: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

ZXG10-BS21 (V2.0)

ZXG10-OB06

ZTE CABINETS

ZXG10-BS30(V1.2)

ZXG10-M8206

Page 23: Zte cabinets

Hardware Structure

M8206

12/04/2023

Delay ALM

LMT

3E1/T1

Abis

ODU

SYS CLK / 13M CLK

ANTANT

48V 48V

ZTE CABINETS

Page 24: Zte cabinets

MDUP MDUP

MTRB

MPWR

48V RTU

Hardware Structure

M8206/RTU

12/04/2023

MPAU

ZTE CABINETS

RTU Interface Board

Page 25: Zte cabinets

MDUP MDUP

MTRBRIB

MPWR

48V RTU

12/04/2023

MPAU

MTRB (Micro Base Station Transceiver Board) consists of transmitter, receiver, local oscillator and base band processor. Main functions of MTRB are as follows:Transmission and reception of radio signal and

uplink/downlink conversion.Processing the dual-carriers radio channels in

downlink. Implement rate adaptation, channel encoding, interleaving, and encryption. Also generates TDMA burst pulse and implements GMSK/8PSK modulation.

Receives the system clock from CMB. Implements and saves hardware management

ID. type, and Board version. Implements RF hopping.

ZTE CABINETS

Hardware Structure

M8206/RTU

Page 26: Zte cabinets

MDUP MDUP

MTRBRIB

MPWR

48V RTU

12/04/2023

MPAU

MPAU (Micro Base Station Power Amplifier Unit) is power amplifying unit and amplifies the downlink signal power. MPAU consists of two power amplifier boards which are installed on the bottom of base station cabinet respectively.

ZTE CABINETS

Hardware Structure

M8206/RTU

Page 27: Zte cabinets

MDUP MDUP

MTRB

MPWR

48V RTU

12/04/2023

MPAU

ZTE CABINETS

Hardware Structure

M8206/RTU

RTU Interface Board

This unit works as a duplexer and consists of transceiver duplexer, antenna interface VSWR detection unit and Low Noise Amplifier (LNA). It detects VSWR alarms in three levels

Page 28: Zte cabinets

MDUP MDUP

MTRB

RTU Interface Board

MPWR

48V RTU

12/04/2023

MPAU

MPWR performs power distribution function. It provides different values of voltage according to the requirements in different parts of the RTU.

ZTE CABINETS

Hardware Structure

M8206/RTU

Page 29: Zte cabinets

MCMB

CIB

MEIB

T150IDU

Heater

48VCTU

12/04/2023

PWR

MMITest5E1/T1

5E1/T1

48V

ZTE CABINETS

Hardware Structure

M8206/CTU

Page 30: Zte cabinets

MCMB

CIB

MEIB

T150IDU

Heater

48VCTU

12/04/2023

PWR

MMITest5E1/T1

5E1/T1

48V

CMB (control and maintenance board) stands for . Monitors, controls and maintains the whole BTS

system.Provides 8 channels E1/T1 interfaces, but only 5

channels are used in this system. Implements the synchronization of radio clock and

transmission clock.Provides transparent path for external environment

alarm. Implements shared PCM link for multi-BTS.Supports cascaded capacity expansion of many

physical cabinets in one site.Provides various clocks required in BTSAdministers the intra-system program of each board

and version of FPGA configuration file. Supports near end and far end version upgrade.

Provides protection from reverse current. Its front panel provides reset button and forced

power OFF button.

ZTE CABINETS

Hardware Structure

M8206/CTU

Page 31: Zte cabinets

MCMB

CIB

MEIB

T150IDU

Heater

48VCTU

12/04/2023

PWR

MMITest5E1/T1

5E1/T1

48V

CIFB (CTU Interface Board) implements the signal conversion between CMB and the bottom interface.

ZTE CABINETS

Hardware Structure

M8206/CTU

Page 32: Zte cabinets

MCMB

CIB

MEIB

T150IDU

Heater

48VCTU

12/04/2023

PWR

MMITest5E1/T1

5E1/T1

48V

MEIB (Micro Base Station E1 Interface Board) performs the following functions:Provides circuit impedance matching for

five E1/T1 channels.Maximum three E1/T1 channels can be

used to connect embedded transmission equipment (optical or microwave transmission). Maximum three can be used for cascading.

Provides link bypass function for E1/T1 channels during the power down of cascading system (i.e. channel ‘A’ bypass to channel ‘C’).

Provides lightening protection, and signal isolation in the circuits.

It provides Abis interface board type information to CMB.

ZTE CABINETS

Hardware Structure

M8206/CTU

Page 33: Zte cabinets

MCMB

CIB

MEIB

T150IDU

Heater

48VCTU

12/04/2023

PWR

MMITest5E1/T1

5E1/T1

48V

T150 is a small capacity AU-4 path STM-1 level SDH equipment. It is usually used outdoors and is the auxiliary transmission equipment of GSM and CDMA BTSs. The function and interfaces are optimized according to the actual requirement of GSM and CDMA. It provides STM-1 (155520 Kbps) link, which is equal to the capacity of four E1 links.

ZTE CABINETS

Hardware Structure

M8206/CTU

Page 34: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

ZXG10-OB06

ZTE CABINETS

ZXG10-BS30(V1.2)

ZXG10-M8206

ZXG10-BS21 (V2.0)

Page 35: Zte cabinets

BTM

CMMBSC

PSM

Um interfaceAbis

Hardware Structure

BS21 (V2.0)

12/04/2023

Heater

TRM

TRM

TMM

ZTE CABINETS

AEM

Page 36: Zte cabinets

BTM

CMMBSC

PSM

Abis

Hardware Structure

BS21 (V2.0)

12/04/2023

Heater

TRM

TRM

TMM

ZTE CABINETS

AEM Um interface

The CMM (Controller & Maintenance Module) implements such functions as Abis interface processing, BTS operation & maintenance, clock synchronization and generation, internal/external alarm collection and processing.

Page 37: Zte cabinets

BTM

CMMBSC

PSM

Abis

Hardware Structure

BS21 (V2.0)

12/04/2023

Heater

TRM

TRM

TMM

ZTE CABINETS

AEM Um interfaceThe BTM (Backboard Transmission Module) is responsible for transmitting messages between the CMM, TRM and AEM and at the same time provides interfaces for inputting and outputting external signals.

Page 38: Zte cabinets

BTM

CMMBSC

PSM

Abis

Hardware Structure

BS21 (V2.0)

12/04/2023

Heater

TRM

TRM

TMM

ZTE CABINETS

AEM Um interfaceThe TMM (Transmission Management Module) is an outsourcing device, and the BS21 only provides one standard chassis (19 inches × 3U) used for the built-in SDH, microwave and other transmission equipment.

Page 39: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

ZTE CABINETS

ZXG10-BS30(V1.2)

ZXG10-M8206

ZXG10-BS21 (V2.0)

ZXG10-OB06

Page 40: Zte cabinets

AEM

BTM

CMMBSC

PSM

Abis

Hardware Structure

BS21 (V2.0)

12/04/2023

Heater

TRM

TRM

TMM

ZTE CABINETS

Um interface

Page 41: Zte cabinets

12/04/2023

Knowledge sharing sessions

ZXG10-BTSV2.0

Thank you!

ZXG10-BS30(V1.2)

ZXG10-M8206

ZXG10-BS21 (V2.0)

ZXG10-OB06