zoll autopulse presentation

32
AutoPulse ® Load - Distributing Band CPR

Upload: brosenfeld

Post on 16-Jul-2015

209 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Zoll autopulse Presentation

AutoPulse®

Load-Distributing Band CPR

Page 2: Zoll autopulse Presentation

AutoPulse®

What it is?

• Automated chest compression device

• “Load-distributing band” (LDB) technology

What does it do?

• Chest compressions that humans can’t possibly do

• Consistent, uninterrupted (never gets tired)

• Moves more blood, more effectively

Page 3: Zoll autopulse Presentation

Consistent Compressions

• Each one the same

Custom Compressions

• Tailored to deliver 20% displacement to each patient

Safer Compressions• Load distribution = distributed force

AutoPulse Delivers…

Page 4: Zoll autopulse Presentation

AutoPulse Benefits

Patients• Increases chances of survival

Caregiver• Allows them to deliver patient care

• Free to deliver other important therapies

Organization• Helps save more lives

• Promotes “leading-edge” view

Page 5: Zoll autopulse Presentation

AutoPulse – Not Intended For

Traumatic injury

• Sudden physical injury

• Violence

AutoPulse compressions may Increase

Hemorrhaging, Resulting in Hypovolemia

Page 6: Zoll autopulse Presentation

Perfusion is the single most

important factor for successful

resuscitation

FACT:

Page 7: Zoll autopulse Presentation

Circulation is Critical for Survival

Provides oxygen to

preserve vital organ

function

Converts non-shockable

rhythms (asystole, PEA) to

shockable ones (VF, VT)

Peberdy MA et al. Resuscitation. 2003;58:297-308.

Page 8: Zoll autopulse Presentation

VF Changes Over Time

-0.4

-0.2

0

0.2

0.4

0.6

-0.4

-0.2

0

0.2

0.4

0.6

Onset of VF

5 Minutes VF

Page 9: Zoll autopulse Presentation

CPR and VF

-0.4

-0.2

0

0.2

0.4

0.6

-0.4

-0.2

0

0.2

0.4

0.6

5 Minutes of VF

After 3 Minutes of Effective CPR

Eftestol et al Circulation 2004;110;10-15

Page 10: Zoll autopulse Presentation

Coronary Perfusion and ROSC

Victims with CPP <15

mmHg do not achieve

ROSC.

The mean CPP with

manual compressions is

12.5 mmHg.

Coronary Perfusion Pressure

Predicts ROSC

Paradis NA et al. JAMA. 1990;263:1106-1113.

Page 11: Zoll autopulse Presentation

Coronary Perfusion and ROSC

A well perfused myocardium is more likely to

experience return of spontaneous circulation (ROSC)

Page 12: Zoll autopulse Presentation

Quality of CPR

Evidence and Effects

Page 13: Zoll autopulse Presentation

Guidelines 2010: CPR

Adequate rate of “at least 100/minute”

Compression [sternal] depth of “at least 2 inches (5 cm)”

Allowing complete chest recoil after each compression

Ventilation: 8 -10 breaths per minute

Minimizing interruptions in compressions

Avoiding excessive ventilations (8-10 breaths/minute)

Page 14: Zoll autopulse Presentation

Challenges to Effective CPR

Limits of sternal compressions

Poor quality compressions

• Inconsistent rate

• Poor depth

• Improper duty cycle

Harmful interruptions due to

• Clinician fatigue

• Patient movement

Incomplete release“…chest compressions were not

delivered half the time, and most

compressions were too shallow…”Lars Wik, MD et al. JAMA. 2005;293(1):299-304.

Page 15: Zoll autopulse Presentation

Manual CPR and Blood Flow

30% - 40% of normal flow

Manual CPR provides less than optimal blood flow to

the heart and brain

10% - 20% of normal flow

Kern KB Bailliere’s Clinical Anaesthesiology. 2000;14(3):591-609.

Page 16: Zoll autopulse Presentation

20

94%

72%

60%

38%

0%

20%

40%

60%

80%

100%

<10.0 10.1-20.0 20.1 - 30.0 >30.0

Sh

oc

k S

uc

ce

ss

Pre-Shock Pause (sec)

p=0.002

Edelson et al, Resuscitation. 2006; 71:147-145

Pauses

How Much Does It Matter?

Page 17: Zoll autopulse Presentation

Sure, Smart, Safe

21

Positioning Strategy

Page 18: Zoll autopulse Presentation

Load Distributing Band Mechanism

Page 19: Zoll autopulse Presentation

Three Points of Focus

The only mechanical CPR system to

show significant clinical benefits in

comparative human trials.Sure

Intelligence that optimizes compressions

for each patient.Smart

Effective compressions without the risk

of higher injury rates.Safe

Page 20: Zoll autopulse Presentation

Improved Vital Signs

Human Studies Show

Systolic BPs > 100 mmHg

SpO2 Values Consistently > 90%

Increased CO2 levels

Timerman et al. Resuscitation 61 (2004) 273–280

Swanson et al. Circulation 2008:118:S-767

Duchateaux et al. Intensive Care Med 101007/s00134-010-1784 Gonin et al. Rev des Samu 2005;27:152-3. Liu et al. Chinese Critical Care Medicine 2010 Nov;22(11):660-2.

Multiple comparative studies

demonstrated vital signs improve in

humans because the AutoPulse

drives superior blood flow.

Timerman et al. Resuscitation 61 (2004) 273–280

Swanson et al. Circulation 2008:118:S-767

Duchateaux et al. Intensive Care Med 101007/s00134-010-1784 Gonin et al. Rev des Samu 2005;27:152-3. Liu et al. Chinese Critical Care Medicine 2010 Nov;22(11):660-2.

Timerman et al. Resuscitation 61 (2004) 273–280

Swanson et al. Circulation 2008:118:S-767

Duchateaux et al. Intensive Care Med 101007/s00134-010-1784 Gonin et al. Rev des Samu 2005;27:152-3. Liu et al. Chinese Critical Care Medicine 2010 Nov;22(11):660-2.

Timerman et al. Resuscitation 61 (2004) 273–280

Swanson et al. Circulation 2008:118:S-767

Duchateaux et al. Intensive Care Med 101007/s00134-010-1784 Gonin et al. Rev des Samu 2005;27:152-3. Liu et al. Chinese Critical Care Medicine 2010 Nov;22(11):660-2.

Timerman et al. Resuscitation 61 (2004) 273–280

Swanson et al. Circulation 2008:118:S-767

Duchateaux et al. Intensive Care Med 101007/s00134-010-1784 Gonin et al. Rev des Samu 2005;27:152-3. Liu et al. Chinese Critical Care Medicine 2010 Nov;22(11):660-2.

Sure

Page 21: Zoll autopulse Presentation

Improved Coronary Perfusion

Human Study

CPP produced by Load

Distributing Band was 33% higher

than with sternal compressions.

Timerman S et al. Resuscitation. 2004;61:273-280.

AutoPulse drives CPP to levels

sufficient to achieve ROSC.

Paradis NA et al. JAMA. 1990;263:1106-1113.

*p=0.015

Sure

Page 22: Zoll autopulse Presentation

CPP drops quickly

when AutoPulse

compressions stop

Manual CPR

CPP returns after

several AutoPulse

compressions

AutoPulseAutoPulse

Human Hemodynamics Study

Timmerman S et al. Resuscitation. 2004;61:273-280.

Page 23: Zoll autopulse Presentation

Improved ROSC

AutoPulse consistently shows improved ROSC

rates compared to sternal compressions.Sure

Page 24: Zoll autopulse Presentation

Improved Survival to Discharge

Ong et al. Circulation 2010;122:A100Ornato J et al. JAMA. 2006;295(22):2629-2637.

Controlled trials in humans demonstrate the

AutoPulse improves survival.

1,011 patients

OR, 2.27; 95% CI, 1.11-4.77

783 patients

OR: 3.99; 95% CI, 1.06-15.02

Sure

IMPROVEMENT IMPROVEMENT

Page 25: Zoll autopulse Presentation

Individualized Compressions

Smart

AutoPulse delivers a 20%

anterior-posterior

compression for each

patient.

Accounts for patient-to-

patient variability

2-inch compression has different effects

on varying chest sizes.

Human Anatomies Differ

Page 26: Zoll autopulse Presentation

Force Adjusted to Chest Stiffness

Smart

The AutoPulse Load Sensor

Control system adjusts force to

insure the difficult [larger, stiffer]

patients get the correct

compression.

Designed to deliver target

compression on patients through

the 95th percentile for size and

stiffness.

Tomlinson AE, et al., Compression force-depth relationship during out-of hospital cardiopulmonary

resuscitation, Resuscitation 2006.07.017

The force required to deliver an adequate chest

compression can differ by 400 percent.

Human Chest Stiffness

Page 27: Zoll autopulse Presentation

Automatically Sized to Patient

Every patient gets a safe and effective

compression.Smart

Eliminates operator error

• No under compression

• No over compression

Minimizes risk of

chest injury

Ensures complete chest

release to optimize

circulation

Page 28: Zoll autopulse Presentation

Review Resuscitation Events

Debriefing of actual resuscitation

events can be a useful strategy to

improve future performance, Class IIa

AutoPulse & RescueNet® Code Review

The most comprehensive out-of-hospital

review system

• Both manual CPR and AutoPulse

compressions

• Plus shock, monitor, intervention data

Smart

Page 29: Zoll autopulse Presentation

Force Distributed Safely

AutoPulse delivers twice the force of

manual compressions.

Force dispersed over large surface area

of the LifeBand.

More effective compressions

without risk of higher injury rates

Safe

Page 30: Zoll autopulse Presentation

Safe

Operates below Injury Threshold

If the amount of pressure applied to chest equals 6 pounds per

square inch, the risk of chest compression injuries climbs.1

1.Knoell CK. Thoracic response to blunt frontal loading SH. Published by

Society of Automotive Engineers, Inc. 1976.

The pressure applied to the chest with AutoPulse

is well below the injury threshold.

Page 31: Zoll autopulse Presentation

Safe

Detects and Alerts Un-Safe Situations

Automatic detection of

LifeBand out of starting

position

Unexpected patient

movement

Incorrect patient alignment

The AutoPulse minimizes patient injury by halting

compression should the patient or LifeBand move to

an unsafe position.

Page 32: Zoll autopulse Presentation

In Summary

The only mechanical CPR system to

show significant clinical benefits in

human comparative trialsSure

Smart

Effective compressions without the risk

of higher injury ratesSafe

Intelligence that optimizes compressions

for each patient.