zlj24 319u ver01 multi - montaza.lvmontaza.lv/content/files/came/came zlj24 manual.pdfm1 n1 e1 m2 n2...

32
Z SERIES INSTALLATION MANUAL ZLJ24 CONTROL PANEL FOR 24V OPERATORS English EN

Upload: others

Post on 14-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • Z SE

    RIES

    INSTALLATION MANUAL

    ZLJ24

    CONTROL PANEL FOR 24V OPERATORS

    English EN

  • Pag.

    22 -

    Man

    ual c

    ode:

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    4 Description

    1 Legend of symbols

    This symbol indicates sections to be read with particular care.

    This symbol indicates sections concerning safety.

    This symbol indicates notes to communicate to users.

    2 Intended use and application

    The ZLJ24 control panel is engineered to command 24V D.C. automation for swing gates of the Axo-Frog-Ferni-Fast series.

    The use of this product for purposes other than as described above and installation executed in a manner other than as instructed in this technical manual are prohibited.

    3 Reference Standards

    “IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS”

    “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”

    “THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS”

    For its quality processes management Came Cancelli Automatici is ISO 9001:2000 certified, and for its environmental management it is ISO 14001 certified. Came designs and manufactures entirely in Italy.This product complies with the following standards: see Declaration of Compliance.

    Make sure you respect the distances and cable diameters as shown in “cable types and minimal thicknesses” table. The overall power of the motors must not exceed 500 W.

    This product is engineered and manufactured by CAME cancelli automatici s.p.a. and complies with current safety regulations.Guaranteed 24 months if not tampered with.The control panel works on 230V a.c. of power, 50/60Hz frequency.The command devices and accessories are 24V rated. Warning! Accessories must not exceed an overall total of 50W.

    All connections are protected by quick fuses, see table.

    The input and output contact functions, the timing settings and users’ management, are set and viewed on the display, which is run by software.

    Set up to connect the LB180 board to power the batteries, which, in case of a power failure, intervene automatically. When the power comes back on, the board automatically recharges the batteries.

    FUSES

    a protezione di: fusibile da:

    Electrolock 3.15A-F

    Electronic board (power supply line)

    5A-F = 230V

    24V accessories 2A-F

    Control devices 630mA-F

    Motor 10A-F

    2.1 Intended use

    2.2 Application

    TECHNICAL FEATURES

    Power supply 230V - 50/60Hz

    max. rated power 500W

    Power draw when idling 110mA

    Max power of 24V accessories 50W

    Insulation rating II

    Material ABS

    Protection rating IP54

    operating temperature -20 / +55°C

  • 26V

    0V

    17V

    0

    230V 26V

    0V

    17V

    0

    230V

    8

    1

    11 2

    5

    4

    91015

    13

    14

    17

    1

    7

    3

    12

    16 6

    Pag.

    33 -

    Man

    ual c

    ode :

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    4.1 Dimensions, spans and anchoring holes

    (mm)

    4.2 Main components

    Warning! Before acting on the machinery, cut off the main power supply and disconnect any emergency batteries.

    1 - Transformer 2 - Card fuse 3 - Accessories fuse 4 - Electrolock fuse 5 - Display 6 - Display lighting adjustment trimmer 7 - Memory roll card connector 8 - AF card connector 9 - R700 card connector10 - Open contact error - warning LED11 - Programming buttons12 - Terminal board for connecting13 - Terminal board for 230V a.c. power grid 14 - Line fuse15 - 230V-power signalling LED16 - Motor 1 fuses 217 - Motor 1 fuses 2

  • !!

    15 mm~

    Pag.

    44 -

    Man

    ual c

    ode:

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    Before installing do the following:

    • Check that the panel’s anchoring point is protected from possible blows, and that the anchoring surface is solid. Also check that the anchoring is done using the appropriate bolts, screws etc.;

    • Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent (sectioned off) power supply;

    • Make sure that any connections inside the case (that provide continuance to the protective circuit) are fitted with extra insulation as compared to the other conductive parts inside;

    • Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage.

    Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.Here are some examples.

    5 Installation

    5.1 Preliminary checks

    5.2 Tools and materials

    Installation must be carried out by expert qualified personnel and in full observance of regulations in force.

    1) Fix the base of the panel in a protected area; we suggest using round top Phillips recessed head screws of max. 6mm in diameter.

    5.3 Fixing and mounting the box

    2) Perforate the pre-punched holes and insert the cable glands with the corrugated tubing for the electrical cables to travel through.

    N.B.: diameter of the pre-punched holes: 20 mm.

    3) Assemble the pressure hinges.

    4) Insert the pressure hinges into the box (on the left or right as you wish) and set them using the provided screws and washers.

    They must slide in order to tum

  • L

    + -

    Pag.

    55 -

    Man

    ual c

    ode :

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    * AXO ** FROG-A24, F4024, FERNI, FROG-A24E *** FROG-A24E

    N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter based on the actual power draw from the connected devices and according to the CEI EN 60204-1 standards.For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and distances.When connecting products that are not specified in this manual, please follow the documentation provided with said products.

    6.1 Cable and type and section

    ConnectionsType

    of cableLength of cable

    1 < 10 mLength of cable10 < 20 m

    Length of cable 20 < 30 m

    Control panel power supply

    FROR CEI 20-22

    CEI EN 50267-2-1

    3G x 1,5 mm2 3G x 1,5 mm2 3G x 2,5 mm2

    Power to motor* with encoder 3G x 1,5 mm2 3G x 1,5 mm2 3G x 2,5 mm2

    Power to motor** 2G x 1,5 mm2 2G x 1,5 mm2 2G x 2,5 mm2

    flashing lamp 2 x 1,5 mm2 2 x 1,5 mm2 2 x 1,5 mm2

    Transmitter photocells 2 x 0,5 mm2 2 x 0.5 mm2 2 x 0,5 mm2

    Receiver photocells 4 x 0,5 mm2 4 x 0,5 mm2 4 x 0,5 mm2

    Power supply to accessories 2 x 0,5 mm2 2 x 0,5 mm2 2 x 1 mm2

    Limit switch** connection 3 x 1,5 mm2 3 x 1,5 mm2 3 x 2,5 mm2

    Control and safety devices 2 x 0,5 mm2 2 x 0,5 mm2 2 x 0,5 mm2

    Encoder*** connection 2402C 22AWG max. 30 m

    Antenna connection RG58 max. 10 m

    6 Electrical connections

    6) After the adjustments and settings, fix the cover using the provided screws.

    5) Snap the cover into place onto the hinges. Close it and fix it using the provided screws.

    Terminals for powering the following accessories: - 24V A.C. Overall power allowed: 50W

    Power supply to accessories

    Power supply 230V (A.C.) 50/60 Hz

    Electrolock connection (12V - 15W max)

    Possible output of the radio receiver’s second channel

    (N.O. socket). Socket rating: 500mA-24V

    (D.C.).

    6.2 Electrical connections

  • CAME

    ACC

    ESS CO

    NTR

    OL

    CANCELLI AUTOMATICI

    R700

    Pag.

    66 -

    Man

    ual c

    ode:

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    Cycle lamp: (contact rating: 24V – 25W max.) It lights up the driving area and stays on from the moment the gate begins to open until it is fully closed (including the automatic closing time). If automatic closing is not activated, the lamp stays on only during movement.

    Signal Flasher (socket rating: 24V - 25W max.) Flashes during opening and closing phases.

    Signalling and Lighting devices

    Command devices

    Stop button (N.C. contact) - Button to stop gate while excluding the automatic closing cycle. For movement to resume you must press the command button or transmitter button.N.B.: if contact is unused, select Disabled on the “FUNCTIONS” menu.

    Key selector and/or opening button (N.O. contact) - Gate opening command.

    Key selector and/or commands button (N.O. contact) - Commands for opening and closing the gate – pressing the button or turning the key-switch, inverts the gate’s movement or stops it depending on how it is set on the 2-7 command in the “FUNCTIONS” menu.

    Key selector and/or partial opening button (N.O. contact) - Partial gate opening for pedestrian access.

    Key selector and/or closing button (N.O. contact) - Gate closing command.

    Open gate indicator-light (socket rating: 24V - 3W max.).

    Turns on when the gate is ajar or open. It turns off when the gate is closed.

    TSP00 - Transponder sensor

    N.B. : insert the (R700) coding board to have the (TSP00) sensor or (LT001) card reader recognised.

    LT001 - Magnetic card reader

    BlackRed

    Antenna with RG58 cable for the remote

    control.

  • M1 N1 E1 M2 N2 E2 2 FA1 FC1 FA2 FC2

    RX TX

    RX TX

    F4024

    FERNIFROG-A24

    F4024

    M1 N1 E1 + E - M2 N2 E2 + E -

    FROG A24E

    ENCODER BENCODER A

    AXO AXO

    FERNIFROG-A24

    FROG A24E

    Pag.

    77 -

    Man

    ual c

    ode :

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    M1 - 24V D.C. gearmotor featuring delayed action on opening M2 - 24V D.C. gearmotor featuring delayed action on closing

    Safety devices

    Confi gure either (N.C.) contacts CX, CY or CZ, input for safety devices such as photocells, that comply with EN 12978 standards. See CX, CY or CZ input functions in:

    - C1 «re-open during closing phase», When the gate leaf is closing, opening the contact triggers the inversion of the direction of movement until the gate leaf is fully open.

    - C2 «re-close during opening phase», When gate is opening, if the contact is opened it triggers an inversion of the direction until gate is fully closed;

    - C3 «partial stop», Halts moving gate leaves and causes them to automatically close (if this functions has been selected);

    - C4 «stand-by Obstacle», Halts the moving gate leaves causing them to start moving again once obstacle is removed.

    - Deactivated, if contact is unused.

    DIR photocells

    DOC photocells

    Gearmotor, mechanical stops

    Gearmotor, encoder

    M1 - 24V D.C. gearmotor featuring delayed action on opening M2 - 24V D.C. gearmotor featuring delayed action on closing

    WhiteBrownGreen

    GreenBrownWhite

  • DF

    (DOC) (DIR)

    Pag.

    88 -

    Man

    ual c

    ode:

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    DF with DFI connections monitor card

    At each opening and closing command, the control board assesses the effi ciency status of the control devices (photocells). Any anomaly found is signalled with the fl ashing of the LED on the control panel. Consequently it cancels any commands coming from the remote control or the button.

    Electrical connection to enable the photocell safety test:- the transmitter and the receiver, must be connected as per the diagram;- from the functions menu, select “safety tests” and select either CX - CY - CZ input/s to activate the test.

    6.3 Electrical connection for the photocells functions test

    Confi gure either (N.C.) contacts CX, CY or CZ, input for EN 12978 compliant safety devices such as sensitive edges. See CX input functions in:

    - C7 «Open while closing», During gate closing, opening the contact causes inversion of movement until gate is fully open;

    - C8 «close while opening», During gate opening, opening the contact causes inversion of movement until gate is fully close.

    - Deactivated, if contact is unused.

  • LinguaItaliano

    { {

    {

    {

    Pag.

    99 -

    Man

    ual c

    ode :

    319

    U98

    319U

    98 v

    er. 0

    .10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    To enter the menu, keep the ENTER key pressed for at least one second.

    To select a menu item, mode using the greater than-lesser than keys...

    ...then press ENTER

    also use the greater than-lesser than keys for the “sub-menus”...

    If the are on the TIME function, you may modify the value.

    To increase or reduce values, use the greater than-lesser than keys...

    ...then press ENTER to confirm...

    ...to exit the menu, wait 30 seconds, or press ESC, until start screen is displayed.

    N.B.: when the menu is active, the system cannot be used.

    7 Programming

    ...then press ENTER

    7.2 Browsing the menu

    7.1 Description of display commands

    The ENTER key is for:- entering the menu;- confirming and memorising set values.

    The ESC key is for:- exiting the menu;

    - cancelling modifications.

    The < > keys are for:- shifting from one menu item to another;

    - increase or decrease values.

    the symbols on the display are for:-pointing out the currently, selected item

    LANGUAGE

    English

    LANGUAGE

    EnglishFUNCTIONS

    EnglishTIMING ADJ.

    A.C.T.

    90sCycle Time

    90s

    Cycle Time

    90s

    Cycle Time

    100s

  • ENTER

    >ENTER >

    ENTER

    >

    >

    ENTER

    ENTER

    ENTER >

    >

    >

    >

    >

    >

    ENTER>

    >

    >

    >

    >

    >

    >

    >ENTER

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    ENTER>

    >

    ENTER>

    >

    ENTER>

    >

    ENTER>

    >

    ENTER

    >

    >

    ENTER

    >

    >

    >

    >

    >

    >

    ENTER

    ENTER

    >

    >

    ESC

    >

    ENTER

    Pag.

    1010

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H < Imp. Run >

    < LANGUAGE >

    7.3 Menu structure

    < TIMING ADJ >

    < INFO >

    < T.C.A. >

    < FUNCTIONS >

    < USERS >

    Choose User

    < 0s. >

    < 300s.>

    < 0s. >

    < 300s.>

    < 10s. >

    < 150s.>

    < 1s. >

    < 10s. >

    < 1s. >

    < 60s >

    < 1s. >

    < 60s.>

    < 1s. >

    < 5s. >

    < 1s. >

    < 10s. >

    < 5s. >

    < 60s.>

    Sel.Utente

    Choose User

    Sel.Utente

    Choose User

    Sel.Utente

    Choose User

    Sel.Utente

    < TEST MOT. >TEST MOT.

    < >

    < ENCODER >See detailed functions on pages 19, 20 and 21 (the “ENCODER” function, appears only if selected from the “Config.” function in the FUNCTIONS menu.

    < System Reset >

    < Cycle Time >

    < Op. Delay M1 >

    < Cl. Delay M2 >

    < Lock time >

    < Ram hit time >

    < Ped.opening >

    < Add User >

    < Mod. name >

    < Mod. Code >

    < Remove Usr. >

    < Backup data >

    < Standby Msg. >< Version >

    fw. 3.0

    < No. of Runs >

    16480

    confirm? (no)

    confirm? (yes)

    confirm? (no)

    confirm? (yes)

    confirm? (no)

    confirm? (yes)

    confirm? (no)

    confirm? (yes)

  • ENTER

    ENTER

    ENTER

    ENTER

    >

    >

    >

    >

    >

    >

    >

    >ENTER

    >

    >

    >

    >

    >

    >

    >

    >ENTER

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >ENTER

    >

    >

    ENTER

    >>ENTER

    >

    ENTER

    >

    >

    >

    >

    >

    •••

    •••••

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    ENTER

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >>

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    >

    Pag.

    1111

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < Disabled >

    < C1 >

    < C4 >

    < C2 >

    < C3 >

    < Turn on >

    < CX+CZ >

    < CX+CY >

    < CY+CZ >

    < Preflashing >

    < Total Stop >

    < CX Input >

    < Lock >

    < Config. >

    < end stop >

    < cmd 2-7 >

    < lamp E >

    < C7 >

    < C8 >

    < Slow run >

    < Limit switch>

    < Time of Run >< encoder >

    < M2 >

    Frog

    FROG-J

    < 50 >

    < 100 >

    < 20 >

    < 50 >

    < Turn on >

    < Turn on >

    < 0s. >

    < 30s. >

    < Turn on >

    AMICO

    AXO

    FERNI

    FAST

    < Turn on >

    < Turn on >

    < Turn on >

    < Turn on >

    < Turn on >

    < Turn on >

    < Parzial >

    < Cycle >

    < Flashing >

    < Bistable >

    < N.C. >

    < N.O. >

    < Disabled >

    < C1 >

    < C4 >

    < C2 >

    < C3 >

    < C7 >

    < C8 >

    < Disabled >

    < C1 >

    < C4 >

    < C2 >

    < C3 >

    < C7 >

    < C8 >

    < Disabled >

    < CX >

    < CY >

    < CZ >

  • X 2

    X 2

    Pag.

    1212

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    LANGUAGE

    < English >LANGUAGE

    < Francais >

    LANGUAGE

    < Deutsch >

    LANGUAGE

    < Espanol >

    LANGUAGE

    < Italiano >

    7.4 Main menu

    Press ENTER for 1 second

    7.5 Language menu

    Select language: selects among the languages displayed.

    7.6 Functions menu

    < AutoClose >

    Turn on

    AutoClose

    < Turn on >

    AutoClose

    < Disabled >

    Automatic Closing: activates or deactivates the automatic closing function.The automatic closing timer activates at each opening endpoint. The predetermined time may be adjusted, and is in any case dependent on any safety devices that may activate; and it does not activate after a total safety “stop” or during a power outage.

    < TIMING ADJ. >

    Maintained Act

    < Disabled >

    Disabled

    Maintained action: the gate works by keeping the button pressed (button 2-3 for opening, button 2-4 for closing, or if set to the “On Closing” function, only with button 2-4.

    Maintained Act

    < when close >

    < USERS >

    250

    < INFO >

    Max. 250 users

    < ENCODER >

    < TEST MOT. >

    It appears only if selected from the “Config.” Section in the FUNCTIONS menu.

    < LANGUAGE >

    English< FUNCTIONS >

    Maintained Act

    < Turn on >

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >

    English

    FUNCTIONSFUNCTIONS

    TIMING ADJ.IMING ADJ

    USERS

    INFO

    Imp. Runn

  • X 2

    X 2

    X 4

    X 2

    X 5

    X 2

    X 3

    X 2

    Pag.

    1313

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    Disabled

    Safety d.Test

    < Disabled >Safety d.Test

    < CX >

    Safety d.Test

    < CY >

    Safety d.Test

    < CZ >

    Safety d.Test

    < CX+CY >

    Safety d.Test

    < CX+CZ >

    Safety d.Test

    < CX+CY+CZ >

    Obstacle Det.

    < Disabled >

    Disabled

    Obstacle Det.

    < Turn on >

    Obstacle detected: when motor is stopped (gate closed or after a total stop command) it prevents any movement if safety devices, such as photocells, detect any obstacles.

    Safety test: allows the card to check the efficiency of any safety devices (i.e. photocells) after every opening or closing command.

    Preflashing

    < Disabled >

    < Preflashing >

    Disabled

    Pre-flashing: after an opening or closing command, the flashing light, connected to W-E, starts flashing before the gate begins its run (to set the time, see “Pre-flashing timing” from the Adjust Timings menu

    Ram hit funct.

    < Disabled >

    Disabled

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Runn

    Ram blow: before any opening run, the gate leaves will press onto the mechanical endstop for a few seconds, to help release the elec-trolock (to set the time, see “Starting ram timing” in the Adjust Timings menu).

    Ram hit funct.

    < Turn on >

  • X 2

    X 8

    X 2

    X 7

    X 2

    X 6

    Pag.

    1414

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < CY Input >

    Disabled

    CY Input

    < Disabled >

    CY Input

    < C2 >

    CY Input

    < C3 >

    CY Input

    < C4 >

    CY Input

    < C1 >

    CY Input

    < C7 >

    CY Input

    < C8 >

    CX input: the N.C. safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges) or, be deactivated. See safety devices on electrical connections.

    < CX Input >

    Disabled

    CX Input

    < Disabled >

    CX Input

    < C2 >

    CX Input

    < C3 >

    CX Input

    < C4 >

    CX Input

    < C1 >

    Total Stop

    < Turn on >

    < Total Stop >

    Turn on

    Total Stop

    < Disabled >

    Total Stop: this function stops the gate and consequently excludes any automatic closing cycle; for movement to resume, you need to use the keypad or transmitter. Insert safety device on [1-2]; Insert the safety device on [1 -2]; if unused, select “Deactivated”

    CX Input

    < C7 >

    CX Input

    < C8 >

    CY input: safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges) or, be deactivated. See safety devices on electrical connections.

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

  • X 2

    X 9

    X 2

    X 11

    X 2

    X 10

    X 2

    X 12

    Pag.

    1515

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    Lock: to lock the gate leaves. Required for gate leaves longer than 2.50 m.

    CZ input: safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges) or, be deactivated. See safety devices on electrical connections.

    Closing thrust: at the endpoint stage during closing, the gearmotors perform a final closing-thrust of the doors for a few seconds.

    Cl. Thrust.

    < Disabled >

    < Cl. Thrust. >

    Disabled

    Cl. Thrust.

    < Turn on >

    Config.

    < Fcap-RallCh >

    Config.

    < encoder >

    < CZ Input >

    Disabled

    CZ Input

    < Disabled >

    CZ Input

    < C1 >

    CZ Input

    < C2 >

    CZ Input

    < C3 >

    CZ Input

    < C4 >

    CZ Input

    < C7 >

    CZ Input

    < C8 >

    Lock

    < Disabled >

    < Lock >

    Disabled

    Lock

    < Turn on >

    < Config. >

    Slow run

    Config.

    < Slow run >

    Config.

    Config.

    Configuration:- ecoder: managing decelerations, obstacle detection and sensitivity, (default function); (AXO, AMICO, FROG-A24E and FROG-J)- slow run: decelerations when opening and closing;- Fcap-RallCh.: end stop when opening and deceleration when closing;- Time of Run: timed end stop;- Limit switch (endstop): opening and closing endstop (FROG-A24 and F4024)

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Runn

  • X 2

    X 2

    X 2

    X 2

    X 15

    X 16

    X 13

    X 14

    Pag.

    1616

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < endstop >

    N.C

    endstop

    < N.C >

    Endstop: configure the endpoints are normally closed or open contacts.N.B.: this function appears only if selected from the “Config.” function in the FUNCTIONS menu.

    < cmd 2-7 >

    Op.-Stop-Cl.

    cmd 2-7

    Command 2-7: setting the 2-7 contact to step-by- step mode (open-close) or sequential (open-stop-close-stop).

    endstop

    < N.A >

    cmd 2-7

    < cmd 2-3P >

    Pedestrian

    cmd 2-3P

    < Pedestrian >

    cmd 2-3P

    < Partial >

    < lamp E >

    Cycle

    lamp E

    < Cycle >

    lamp E

    < Preflashing >

    Command 2-3P: setting the 2-3P contact to pedestrian opening (second gate leaf opens fully) or partial (second gate leaf opens partially depending on the time set on “Partial opening” from the Adjust Times menu).

    Lamp E: setting up the fl ashing light or cycle lamp connected on 10-E:- cycle: outdoor lamp, which can be positioned at leisure, for better illumination in the parking/driveway area.It stays on from the moment the gate leaf begins to open, until it is fully closed (including automatic closing time).In case the automatic closing function is not inserted, it stays on only during gate movement.- fl ashing light: signals the gate opening or closing movement.

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    INFO

    Imp. Runn

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Runn

  • X 2

    X 2

    X 17

    X 2

    X 2

    X 2

    Pag.

    1717

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < LANGUAGE >ANGUAG

    EnglishE

    FUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Runn

    B1-B2 output: setting contact B1-B2 to MONO-STABLE or BI-STABLE (switch) mode.

    Number of motors: setting the number of motors, either one or two, depending on the number of gate leaves installed on the system.

    < output B1-B2 >

    Monostable

    output B1-B2

    < Bistable >

    output B1-B2

    < Monostable >

    7.7 Gate-Run Setting Menu

    Motor Type: setting up the type of swing gate motor installed in the system.

    % speed of action: setting up the speed during gate operation, expressed as a percentage between 50% and 100%.

    < Motor type >

    FROG

    Motor type

    < FROG >

    Motor type

    < AMICO >

    Motor type

    < AXO >

    Motor type

    < FROG-J >

    Motor type

    < FAST >

    Motor type

    < FERNI >

    < High speed % >

    50

    High speed %

    < 50 >

    High speed %

    < 51 >

    < No. Motors >

    M1 + M2

    No. Motors

    < M1 + M2 >

    No. Motors

    < M2 >

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

  • X 3

    X 2

    X 4

    X 2

    X 5

    X 2

    X 6

    X 2

    Pag.

    1818

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    % speed of deceleration: setting up the deceleration speed, expressed as a percentage between 50% and 100%.

    Delayed start: After an open or close command, the gate leaves start at a slow speed for a few seconds.

    Amperometric sensitivity: the level of gearmotor sensitivity in the face of obstacles during operation.When the amperometric sensitivity is on, and an obstacle is engaged, depending on how the configuration, the gearmotor works in the following ways:- timed endpoint: it stops while performing a gate run;- end point: it inverts direction of travel during operation;- decelerations: it inverts direction of travel during operation, while during the deceleration phase it stops;- Fcap-RallCh.: it inverts direction of travel during operation, while during the deceleration phase it only stops when on a closing run.When the amperometric sensitivity is off, and an obstacle is engaged, the gearmotor stops when the maximum current threshold is exceeded (i.e. overload).N.B.: this function appears only if the “encoder” function is not selected in the FUNCTIONS menu.

    Gate run amperometrics: setting the gearmotor sensitivity in the presence of obstacles.N.B.: this function only appears if the amperometric sensitivity is selected.

    Less sensitive

    More sensitive

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < low Down Spd >

    20

    low Down Spd

    < 20 >

    low Down Spd

    < 21 >

    < Slow Star >

    Disabled

    Partenza Rall.

    < Disabled >

    Partenza Rall.

    < Turn on >

    < Sens. Amperom >

    Disabled

    Sens. Amperom

    < Disabled >

    Sens. Amperom

    < Turn on >

    -oooooooooooo+

    Run Amperom

    Run Amperom

    ••• •••

    ••••

  • X 2

    X 7

    X 2

    X 2

    X 2

    X 2

    Pag.

    1919

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < Slow down time >

    0s.

    Slow down time

    < 0s. >

    Slow down time

    < 1s. >

    Deceleration time: gate leaf deceleration time before each endpoint. The time can be set anywhere between 0” to 30”.N.B.: this function only appears if the decelerations and Fcap-RallCh. are selected.

    < LANGUAGE >ANGUAG

    EnglishE li h

    FUNCTIONSFUNCTIONS

    TIMING ADJ.I J

    USERS

    Imp. Run

    < Sensib. Run >-oooooooo+

    Sensib. Run

    < -oooooooo+ >

    Sensib. Run

    < -oooooooo+ >

    Gate operation sensitivity: this adjusts the obstacle detection sensitivity during opening and closing gate operation.N.B.: this function appears only if the “sensitivity” function is activated in the ENCODER menu.

    < Sensibility >

    Turn on

    Sensibility

    < Turn on >

    Sensibility

    7.7 Encoder Menu (the ENCODER menu, appears only if selected from the “Config.” function in the FUNCTIONS menu.)

    Sensitivity: the obstacle detection function is activated during gate operation and deceleration.

    N.B.: before setting the functions in the encoder menu, run the gearmotor checks to verify the proper turning direction.

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. corsaI s

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    -oooooooo+

    Sensib. Decel.

    < -oooooooo+ >

    Sensib. Decel.

    < -oooooooo+ >

    Deceleration sensitivity: it adjusts the obstacle detection sensitivity during opening and closing gate deceleration.N.B.: this function appears only if the “sensitivity” function is activated in the ENCODER menu.

    Less sensitive

    More sensitive

    Less sensitive

    More sensitive

  • X 3

    X 2

    X 4

    X 2

    X 5

    X 2

    X 6

    X 2

    Pag.

    2020

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    Encoder Deceleration: this activates the opening and closing deceleration starting points.

    M1 opening deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the opening endpoint.The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

    M1 closing deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the closing endpoint. The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

    M2 opening deceleration%: this adjusts the (M2) second motor’s deceleration starting point before the opening endpoint.The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

    < Slow run Enc >

    ON

    Slow run Enc

    < ON >

    Slow run Enc

    < OFF >

    < M1 Slow.AP.% >

    10

    M1 Slow.AP.%

    < 10 >

    M1 Slow.AP.%

    < 11 >

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    < M1 Slow.CH % >

    10

    M1 Slow.CH %

    < 10 >

    M1 Slow.CH %

    < 11 >

    < M2 Slow.AP % >

    10

    M2 Slow.AP %

    < 10 >

    M2 Slow.AP %

    < 11 >

  • X 7

    X 2

    X 8

    X 2

    X 9

    X 2

    X10

    X 2

    Pag.

    2121

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    FUNCTIONSF

    TIMING ADJ.T D

    USERS

    INFO

    ENCODER

    Imp. Runn

    < M2 Slow.CH % >

    10

    M2 Slow.CH %

    < 10 >

    M2 Slow.CH %

    < 11 >

    M2 closing deceleration %: this adjusts the (M2) second motor’s deceleration starting point before the closing endpoint.The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

    < M1 Appr.CH % >

    5

    M1 Appr.CH %

    < 5 >

    M1 Appr.CH %

    < 6 >

    M1 closing acceleration %: this adjusts the (M1) first motor’s percentage rate of approach to the final closing and opening points before reaching the opening and closing endpoints. The percentage rate of approach to (goes from 1% to 15% of the full gate run). See illustration on page 28.

    < Set Encoder > Set Encoder

    Set Encoder

    See detailed description on page 28

    M2 closing acceleration %: this adjusts the (M2) second motor’s percentage rate of approach to the final closing and opening points before reaching the opening and closing endpoints. The percentage rate of approach to (goes from 1% to 15% of the full gate run). See illustration on page 28.

    < M2 Appr.CH % >

    5

    M2 Appr.CH %

    < 5 >

    M2 Appr.CH %

    < 6 >

    Gate run calibration: calibrates the gate’s opening and closing runs and decelerations.

  • X 2

    X 2

    X 2

    X 2

    X 3

    X 2

    Pag.

    2222

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    10s.

    Pedestrian ACT

    < 10s. >

    Pedestrian ACT

    < 11s. >

    Automatic Pedestrian Closing: waiting time of the (M2) second gate leaf when in the open position. Once this time interval has elapsed, the gate automatically closes. The waiting time interval can go anywhere from 0” to 300”.

    < A.C.T. >

    10s.

    A.C.T.

    < 10s. >

    A.C.T.

    < 11s. >

    7.8 Time setting menu

    Automatic closing: to set the waiting time when gate is in the open position.Once this time is elapsed, the gate closes automatically. The waiting time can be set to between 0” and 300”.

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    < Cycle Time >

    90s.

    Cycle Time

    < 90s. >

    < Op. Delay M1 >

    2sOp. Delay M1

    < 2s >

    M1 delayed opening: the waiting time of the (M1) first gate lead, unlike the (M2) second one, after each opening command. The waiting time can be set to between 0” and 10”.

    Cycle time: the working time of the motor during opening or closing phases is anywhere from 10” to 150”.

    Cycle Time

    < 91s. >

    Op. Delay M1

    < 3s >

  • X 2

    X 4

    X 2

    X 5

    X 2

    X 6

    X 2

    X 7

    Pag.

    2323

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < Cl. Delay M2 >

    2sCl. Delay M2

    < 2s >

    M2 delayed closing: the waiting time of the (M2) second gate leaf, unlike the (M1) first one, after each closing command. the waiting time can be set to between 0” and 60”.

    Cl. Delay M2

    < 3s >

    5s.

    Preflashing T.

    < 5s. >

    Pre-flashing time: after an opening or closing command is given, the flasher connected to “W-E), flashes for between 1” and 60”, before the gate begins to move.

    Preflashing T.

    < 6s. >

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    < Lock time >

    2s.

    Lock time

    < 2s. >

    Lock time: the time required for releasing the electro-lock after each opening command. The time of operation can be set to between 1” and 5”.

    Lock time

    < 3s. >

    < Ram hit time >

    2s.

    Ram hit time

    < 2s. >

    Ram hit time: the gearmotor’s thrust time when fully closing after each opening command. The thrust time can be set to between 1” and 10”.

    Ram hit time

    < 3s. >

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

  • X 2

    X 8

    X 2

    X 2

    X 2

    X 2

    Pag.

    2424

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < Slow down time >

    5s.

    Slow down time

    < 5s. >

    Slow down time: the gate leaf’s deceleration time before every endpoint. The time can be set to between 0” and 30”.N.B.: this function only appears if the decelerations are selected.

    Slow down time

    < 6s. >

    TIMING ADJ.

    USERS

    INFO

    ENCODERR

    Imp. Runn

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    < Add User > Add User

    Add User: to create a new user and assigned function (max. 250 users).

    < Mod. name > Choose User

    < 001:--001-- >

    Mod. Name: to change a user number or existing name to another name.

    < Mod. Code > Choose User

    < 001:--001-- >

    Mod. Code: to change a user’s current code.

    Choose User

    < 002:--002-- >

    Add User

    See detailed description on page 26

    Choose User

    < 002:--002-- >

    See detailed description on page 26

    See detailed description on page 27

    7.9 Users Radio Menu

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

  • X 3

    X 2

    X 4

    X 2

    X 5

    X 2

    X 2

    X 6

    Pag.

    2525

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    < Related Func >

    Choose User

    < 002:--002-- >

    Choose User

    < 001:--001-- >

    See detailed description on page 27

    Related Function: to change the function assigned to the user.

    Backup data

    Backup data

    < Remove Usr. > Choose User

    < 001:--001-- >

    Remove user: to remove an exisiting user. Confirm the use you wish to remove with the ENTER key.

    < Backup data >

    Backup data: to save the users in the memory roll. Confirm saving of users on the memory roll with ENTER.

    Delete all user: to cancel all registered users. Confirm cancellation of all users with ENTER.

    Choose User

    < 002:--002-- >

    Remove Usr.

    Remove Usr.

    Delete all Usr

    Delete all Usr

    Backup data

    WRITE:250

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

  • X 2

    X 7

    Pag.

    2626

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    Restore backup: to load the data saved on the memory roll onto card.

    Restore backup

    Restore backup

    Restore backup

    READ:250

    7.10 nfo Menu

    < Version >

    fw : 1.0

    Version: to view software version.Number of gate runs: to view the number of runs performed by the gate.Starting Mssg: to view the starting message, confirm with ENTER to change text. Use the ENTER key to move the cursor forward, ESC to move it backwards and to select the letter of number. Confirm the text by pressing the ENTER key for a few seconds.System reset: it resets the system to its original settings. Press ENTER key to confirm.

    - WWW.CAME.IT

    ZM3E

    < System Reset >

    < No. of Runs >

    10

    < Standby Msg. >

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    7.11 Motor test menu

    Gate leaf opening run of the second (M2) gearmotor. If the direction is wrong, invert the motor’s phases.

    Gate leaf opening run of the first (M1)

    gearmotor. If the direction is wrong, invert the motor’s

    phases.

    < TEST MOT. >

    FUNCTIONSSFF

    ENCODERR

    USERS

    INFO

    TEST MOT.TEST MOT.

    Imp. Runn

    FUNCTIONSSF

    ENCODERR

    USERS

    INFO

    TEST MOT.

    Imp. Runn

  • CANCELLI AUTOMATICI

    R700

    ACC

    ESS CO

    NTR

    OL

    Memory roll

    TOP

    TSP00

    LT001

    CAME

    TAM

    ATOMO

    TWIN

    TOUCH

    CAME

    TFM

    Pag.

    2727

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    Frequency/MHz Card Transmitter

    FM 26.995 AF130 TFM

    FM 30.900 AF150 TFM

    AM 26.995 AF26 TOP

    AM 30.900 AF30 TOP

    AM 433.92 AF43S TAM / TOPATOMO / TWIN

    AM 433.92 AF43TW TWIN

    AM 40.685 AF40 TOUCH

    AM 868.35 AF868 TOP

    7.12 Decoding card

    Connect the required (R700, AF43S cards) to insert, change, remove and command the operator via transmitter, card or transponder. Insert the memory roll to save and load all setting including users registered by another card.

    AF Card

    R700 Card

  • ACC

    ESS CO

    NTR

    OL

    Pag.

    2828

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    7.13 Inputting users

    Add UserAdd User

    confirm? (yes)

    1) From the Users menu, select “Add User”.Press ENTER to confirm.

    2) Select “ confirm (yes)” and press ENTER key to confirm.

    --001--

    radio

    4) .... will ask to input a code. Send the code with the radio-command button or slide-through card or transponder.

    5) ... once the code is inputted, the user name will come up showing the type of command that was memorised...

    Code exist

    001:--001--

    ... or if the code is already inputted, “Existing Code” will appear.

    3) Choose which function to assign to the user....

    Related Func.

    2-7 Waiting Code

    >>>>

    7.14 Changing users

    Mod. name

    Choose User

    001:--U001--

    1) From the Users menu, choose “Mod. name”. Press ENTER to confirm.

    2) Choose the user number or name you wish to change the text of and press ENTER to confirm.

    4) Confirm the text by pressing the ENTER key for a few seconds.

    3) Use the ENTER key to move the cursor forward, ESC to move it backwards and < > to select the letter or number.

    Mod. name

    --001-- Mod. name

    JOHN

  • ACC

    ESS CO

    NTR

    OL

    Pag.

    2929

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    7.15 Changing code

    Mod. Code

    1) From the Users menu, choose “Mod. Code”. Press ENTER to confirm.

    2) Choose the user name for which you wish to change the code and press ENTER to confirm.

    4) .. once the code is inputted, the user name will come up showing the type of command that was memorised...

    3) .... you will be asked to input a code. Send the code using the transmitter button or the slide - through card or the transponder.

    --002--

    radio

    7.16 Function assigned to the user

    Related Func.

    1) From the Users menu, choose “Related Fuc.”. Press ENTER to confirm.

    2) Choose the user name fo which you wish to change the command function and press ENTER to confirm.

    4) Choose “confirm (yes)” and press ENTER to confirm.

    3) Choose the new function to assign to the user. Press ENTER to confirm.

    Choose User

    002:--U002--

    Related Func.

    confirm? (yes)

    Choose User

    001:--U001--

    Related Func.

    open

    Related Func.

    2-7

    Choose User

    002:--U002--

    Choose User

    001:--U001--

    Mod. Code

    confirm? (yes)

    Waiting Code

    >>>>

    5) Select “ confirm (yes)” and press ENTER key to confirm.

  • Pag.

    3030

    - M

    anua

    l cod

    e: 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    7.17 Gate run calibration

    1) From the Encoder menu, select “Set Encoder”. Press ENTER to confirm.

    2) Select “confirm (yes) and press ENTER to confirm.

    3) the gate leaf of the first motor will perform a closing run until fully closed.....

    4) …then, the gate leaf of the second motor will perform the same manoeuvre…

    5) …then, the gate leaf of the second motor, will perform and opening run until fully open… 6) ...after which,

    the gate leaf of the first motor will perform the same manoeuvre…

    7) When the procedure is finished, the display will show “Set Encoder ok” for a few seconds.

    N.B. before calibrating the gate run, check that the manoeuvring area is free of any obstacles and check the proper direction of rotation of the gearmotors. (para. 7.11)

    7.18 Error messages

    -“encoder ERROR”: check proper connections or functionality of the device and possibly even the motor’s torque”

    -“safety d. test ERROR”: malfunctioning of safety devices, check proper functioning of connections and functionalities;

    -“end stop ERROR”: check proper connections on end point connections or functionality of devices;

    -“cycle time ERROR”: check the working time settings, the set time may be insufficient to complete the duty cycle.

    - Safety STOP, C1, C3, C4”: check proper functioning of connections and functionalities of devices.

  • D

    B

    A

    B

    D

    B

    B

    D

    A

    D

    E

    F H

    G

    I L

    M

    MM

    C C

    I L

    Pag.

    3131

    - M

    anua

    l cod

    e : 3

    19U

    9831

    9U98

    ver

    . 0.10.1

    01/

    2009

    © C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . - T

    he d

    ata

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.

    EN

    GLIS

    H

    7.19 Illustration depicting the areas and points of deceleration and final opening and closing approaches per encoder device.

    A = Area of movement at normal speedB* = Run zone at decelerated speedC = Encoder intervention zone with

    movement inversionD= Encoder intervention zone with

    movement stopE = Opening deceleration beginning point

    (M1 Open Deceler %)F = Closing deceleration beginning point

    (M1 Close Deceler %)G = Opening deceleration beginning point

    (M2 Open Deceler %)H = Closing deceleration beginning point

    (M2 Close Deceler %)I** = Closing and opening fi nal phase

    beginning point (M1 Final Close %)L** = Closing and opening fi nal phase

    beginning point (M2 Final Close %)M= endstops

    Note: the areas and points of deceleration and fi nal opening and closing approaches are tested according to the parameters set forth by Technical Norms EN12445 and EN12453 regarding compatibility of impact forces generated by moving gate leaves.

    * Minimum 600 mm from the Final full stop. **Set the function’s fi nal phase % “M1 Final Close” for the fi rst (M1) mtors and “M2 Final Close” for the second (M2) motor from the

    “ENCODER” menu so as to obtain a distance of between 1 and 50 mm maximum from the fi nal full stop.

    In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in compliance with the UNI EN ISO 14001 standard to ensure environmental protection.Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal:

    DISPOSAL OF PACKAGINGThe packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste products and may be disposed of easily, keeping in mind recycling possibilities.Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.PLEASE DISPOSE OF PROPERLY!

    PRODUCT DISPOSALOur products are made up of various types of materials. Most of them (aluminium, plastics, iron, electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c recyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, etc.), however, may contain polluting substances. They should therefore be removed and given to qualifi ed service companies for proper disposal.Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.PLEASE DISPOSE OF PROPERLY!

    8 Demolition and disposal In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in compliance with the UNI EN ISO 14001 standard to ensure environmental protection.Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal:

    DISPOSAL OF PACKAGINGThe packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste products and may be disposed of easily, keeping in mind recycling possibilities.Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.PLEASE DISPOSE OF PROPERLY!

    PRODUCT DISPOSALOur products are made up of various types of materials. Most of them (aluminium, plastics, iron, electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c recyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, etc.), however, may contain polluting substances. They should therefore be removed and given to qualifi ed service companies for proper disposal.Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.PLEASE DISPOSE OF PROPERLY!

    MANUFACTURER’S DECLARATION OF CONFORMITYPursuant to the Low Voltage Directive 2006/95/EC

    CAME Cancelli Automatici S.p.A. via Martiri della Libertà, 15 31030 Dosson di Casier - Treviso - ITALY tel (+39) 0422 4940 - fax (+39) 0422 4941 internet: www.came.it - e-mail: [email protected]

    Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:

    … comply with the National Law related to the following European Directives and to the applicable parts of the following Standards.

    2006/95/EC LOW VOLTAGE DIRECTIVE2004/108/EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE

    EN 60335-1 EN 61000-6-2 EN 13241-1 EN 61000-6-3

    IMPORTANT WARNING!Do not use the equipment specifi ed here above, before

    completing the full installationIn full compliance with the Machinery Directive 98/37/EC

    MANGING DIRECTORMr. Gianni Michielan

    ZLJ24

    9 Manufacturer’s warranty

    Reference code to request a true copy of the original: DDF L EN Z002f

  • CAME France S.a.CAME France S.a.7, Rue Des HarasZ.i. Des Hautes Patures92737 Nanterre Cedex - Nanterre Cedex - FRANCE

    (+33) 1 46 13 05 05 (+33) 1 46 13 05 00

    CAME Gmbh SeefeldCAME Gmbh SeefeldAkazienstrasse, 9

    16356 Seefeld Seefeld Bei Berlin - DEUTSCHLAND

    (+49) 33 3988390 (+49) 33 39883985

    CAME Automatismes S.a.CAME Automatismes S.a.3, Rue Odette Jasse13015 Marseille - Marseille - FRANCE

    (+33) 4 95 06 33 70 (+33) 4 91 60 69 05

    CAME GmbhCAME GmbhKornwestheimer Str. 37

    70825 Korntal Korntal Munchingen Bei Stuttgart - DEUTSCHLAND

    (+49) 71 5037830 (+49) 71 50378383

    CAME Automatismos S.a.CAME Automatismos S.a.C/juan De Mariana, N. 17-local28045 Madrid - Madrid - SPAIN

    (+34) 91 52 85 009 (+34) 91 46 85 442

    CAME Americas Automation LlcCAME Americas Automation Llc1560 Sawgrass Corporate Pkwy, 4th Floor

    SunriseSunrise, FL 33323 - U.S.A (+1) 305 433 3307 (+1) 305 396 3331

    CAME Automatismos Catalunya S.a.CAME Automatismos Catalunya S.a.P.i. Moli Dels Frares N. 23 C/a08620 Sant Vicenc Del Horts - Sant Vicenc Del Horts - SPAIN

    (+34) 93 65 67 694 (+34) 93 67 24 505

    CAME Middle East FzcoCAME Middle East FzcoPo Box 17131 Warehouse N. Be02

    South Zone - Jebel Ali Free Zone - Dubai - Dubai - U.A.E. (+971) 4 8860046 (+971) 4 8860048

    Paf - CAMEPaf - CAMEEstrada Nacional 249-4 Ao Km 4,35Cabra Figa - Trajouce2635-047 Rio De Mouro - Rio De Mouro - PORTUGAL

    (+351) 219 257 471 (+35) 219 257 485

    CAME Polska Sp.Zo.oCAME Polska Sp.Zo.oUl. Ordona 1

    01-237 Warszawa - Warszawa - POLAND (+48) 22 8365076 (+48) 22 8363296

    CAME United Kingdom Ltd.CAME United Kingdom Ltd.Unit 3 Orchard Business ParkTown Street, SandiacreNottingham Nottingham - Ng10 5du - UNITED KINGDOM

    (+44) 115 9210430 (+44) 115 9210431

    S.c. CAME Romania S.r.l.S.c. CAME Romania S.r.l.B-dul Mihai Eminescu, Nr. 2, Bloc R2

    Scara A, Parter, Ap. 3Buftea, Judet Ilfov Bucarest - Bucarest - ROMANIA

    (+40) 21 3007344 (+40) 21 3007344

    CAME Belgium SprlCAME Belgium SprlZoning Ouest 77860 Lessines - Lessines - BELGIUM

    (+32) 68 333014 (+32) 68 338019

    CAME RussiaCAME RussiaLeningradskij Prospekt, Dom 80

    Pod’ezd 3, offi ce 608125190, MoskvaMoskva - RUSSIA

    (+7) 495 937 33 07 (+7) 495 937 33 08

    CAME Cancelli Automatici S.p.a.CAME Cancelli Automatici S.p.a.Via Martiri Della Libertà, 1531030 Dosson Di Casier Dosson Di Casier (Tv)

    (+39) 0422 4940 (+39) 0422 4941

    Informazioni Commerciali 800 848095www.came.it

    CAME Nord s.r.l.CAME Nord s.r.l.Piazza Castello, 16

    20093 Cologno Monzese Cologno Monzese (MI) (+39) 02 26708293 (+39) 02 25490288

    CAME Service Italia S.r.l.CAME Service Italia S.r.l.Via Della Pace, 2831030 Dosson Di Casier Dosson Di Casier (Tv)

    (+39) 0422 383532 (+39) 0422 490044

    Assistenza Tecnica 800 295830Assistenza Tecnica 800 295830

    CAME Sud s.r.l.CAME Sud s.r.l.Via F. Imparato, 198

    Cm2 Lotto A/7 80146 Napoli Napoli

    (+39) 081 7524455 (+39) 081 7529109

    Engl

    ish

    Engl

    ish

    - M

    anua

    l cod

    e: ..

    ......

    ......

    ......

    .. ve

    r. ......

    ../.

    ... ©

    CAM

    E ca

    ncel

    li au

    tom

    atic

    i s.p

    .a.

    The

    data

    and

    info

    rmat

    ion

    repo

    rted

    in th

    is in

    stal

    latio

    n m

    anua

    l are

    sus

    cept

    ible

    to c

    hang

    e at

    any

    tim

    e an

    d w

    ithou

    t obl

    igat

    ion

    on C

    AME

    canc

    elli

    auto

    mat

    ici s

    .p.a

    . to

    notif

    y us

    ers.