zf led zoom fresnel · zf led zoom fresnel user manual 4 dmx channel mode: operating in dmx control...

8
Order codes: ELUM090 - 100W 3200K WW Version ELUM091 - 100W 6000K CW Version ELUM092 - 150W 3200K WW Version ELUM093 - 150W 6000K CW Version ZF LED Zoom Fresnel User Manual

Upload: others

Post on 25-Mar-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Order codes: ELUM090 - 100W 3200K WW VersionELUM091 - 100W 6000K CW VersionELUM092 - 150W 3200K WW VersionELUM093 - 150W 6000K CW Version

ZF LED Zoom Fresnel User Manual

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.

• WARRANTY:Twoyearsfromdateofpurchase.

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 3

Product overview & technical specifications

TheZFLEDZoomFresnelisloadedwitha100W(150W)cool(warm)whiteLED,producinganoutputsimilartoa650W(1000W)lamp.Controloftheunitisfacilitatedviaa4buttonmenuandLCDdisplay,whilstthebeamanglecanbemanuallyadjustedbetween12°and60°.Eightdimmercurvesareincludedformaximumflexibility.Thewholefixtureisenclosedinarobustchassis,andissuppliedwithfilterframeandbarndoor.

•1x100WwarmwhiteCOBLED(3200K)-ELUM090

•1x100WcoolwhiteCOBLED(6000K)-ELUM091

•1x150WwarmwhiteCOBLED(3200K)-ELUM092

•1x150WcoolwhiteCOBLED(6000K)-ELUM093

•Manuallyadjustablebeamangle:12°-60°

•CRI>95

•1.6kHzrefreshrate

•DMXchannels:1or2selectable

•0-100%dimming

•4dimmingcurvesinbothLEDandhalogenprofiles:Linear,squarelaw,inversesquarelawandS-curve

•4pushbuttonmenuwithLCDdisplay

•PowerCONinputputput/output

•5-PinXLRinput/output

•3-PinXLRinput/output

•Temperaturecontrolledfancooling

•Handleonrearpanel

•Filterframeandbarndoorsincluded

ZF LED Zoom Fresnel

Specifications ZF LED Zoom Fresnel

Powerconsumption 120W-100WVersion

Powerconsumption 170W-150WVersion

Powersupply 100~240V,50/60Hz

Dimensions 430x270x340mm

Weight 7.3kg

Ordercode ELUM090-100WWWVersion

Ordercode ELUM091-100WCWVersion

Ordercode ELUM092-150WWWVersion

Ordercode ELUM093-150WCWVersion

0m 1m 2m 3m 4m 5m

60°12°

206008630

51602160

2290958

1290539

825345

12° - Lux60° - Lux

100W WW

200007880

50001970

2220875

1250492

800315

12° - Lux60° - Lux

100W CW

2440010200

60902560

27101140

1520641

975410

12° - Lux60° - Lux

150W WW

3380014800

84503690

37601640

2110922

1350590

12° - Lux60° - Lux

150W CW425mm

345mm

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 4

DMX channel mode:

OperatinginDMXcontrolmodegivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.

Toaccessthe1channelDMXmode,pressthe“MENU”buttonontherearoftheunittoshow“DMX-1CH”ontheLCDdisplay.Thefixtureisnowin1Channelmode.Nowusethe“UP”and“DOWN”buttonstosetthedesiredDMXaddressforthe1Channelmode.

Toaccessthe2channelDMXmode,pressthe“MENU”buttonontherearoftheunittoshow“DMX-2CH”ontheLCDdisplay.Thefixtureisnowin2Channelmode.Nowusethe“UP”and“DOWN”buttonstosetthedesiredDMXaddressforthe2Channelmode.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Technical specifications

Operating instructions

01-Earthpoint

02-LCDdisplay

03-Functionbuttons

04-3-PinDMXinput

05-3-PinDMXoutput

06-5-PinDMXinput

07-5-PinDMXoutput

08-PowerCONinput

09-PowerCONoutput

10-FuseT3.15A250V

11-Adjustablezoomknob

Inthebox:1 x fixture, 1 x 13A powerCON mains cable & 1 x user manual

DMX INPUT

DMX OUTPUT

DMX INPUT

DMX OUTPUT

FUSE: T3.15A 250V(T6.3A 125V)

ZOOM

POWER INPUT

100-240V~50/60Hz

POWER OUTPUT

100-240V~50/60Hz

www.prolight.co.uk

ZF Zoom Fresnel

MENUINFO UP DOWN

0507 1011

06 04 0102 03

09 08

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 5

Manual dimming mode:

Toaccessthesoundactivemode,pressthe“MENU”buttonontherearoftheunittoshow“WhiteSet”ontheLCDdisplay.Theunitisnowinmanualdimmingmode.Nowusethe“UP”and“DOWN”buttonstosetthebrightnessfrom“0” - “255”(0 = LED off, 255 = LED at full brightness).

Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

Dimming curves

Toaccesstheunitsdimmercurves,pressthe“MENU”buttonontherearoftheunittoshow“Led Linear”ontheLCDdisplay.Nowusethe“UP”and“DOWN”buttonstosetthedimmingcurverequired.

“Led Linear”-LEDLineardimmingcurve

“Led Square”-LEDSquaredimmingcurve

“Led InvSquar”-LEDInverseSquaredimmingcurve

“Led S-Curve”-LEDS-Curvedimmingcurve

“Halgen Linear”-HalogenLineardimmingcurve

“Halgen Square”-HalogenSquaredimmingcurve

“Halgen InvSquar”-HalogenInverseSquaredimmingcurve

“Halgen S-Curve”-HalogenS-Curvedimmingcurve

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2 000-014 DimmingCurves(setviaunit)

015-044 LinearHalogendimmingcurve

045-074 SquareHalogendimmingcurve

075-104 InverseSquareHalogendimmingcurve

105-134 S-curveHalogendimmingcurve

135-164 LinearLEDdimmingcurve

165-194 SquareLEDdimmingcurve

195-224 InverseSquareLEDdimmingcurve

225-255 S-curveLEDdimmingcurve

2 channel mode:

Channel Value Function

1 000-255 Masterdimmer(0-100%)

1 channel mode:

Pleasenote:Dimmingcurvesfor1channelmodecanbesetviainternalmenu.

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 6

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-511.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 7

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Terminationreducessignaltransmissionproblemsandinterference.ItisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

www.prolight.co.uk ZF LED Zoom Fresnel User Manual 8

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.