zf led zoom fresnel · zf led zoom fresnel user manual 4 dmx channel mode: operating in dmx control...
TRANSCRIPT
Order codes: ELUM090 - 100W 3200K WW VersionELUM091 - 100W 6000K CW VersionELUM092 - 150W 3200K WW VersionELUM093 - 150W 6000K CW Version
ZF LED Zoom Fresnel User Manual
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 2
Safety advice
WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.
OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS
CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoflammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.
• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.
• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Twoyearsfromdateofpurchase.
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 3
Product overview & technical specifications
TheZFLEDZoomFresnelisloadedwitha100W(150W)cool(warm)whiteLED,producinganoutputsimilartoa650W(1000W)lamp.Controloftheunitisfacilitatedviaa4buttonmenuandLCDdisplay,whilstthebeamanglecanbemanuallyadjustedbetween12°and60°.Eightdimmercurvesareincludedformaximumflexibility.Thewholefixtureisenclosedinarobustchassis,andissuppliedwithfilterframeandbarndoor.
•1x100WwarmwhiteCOBLED(3200K)-ELUM090
•1x100WcoolwhiteCOBLED(6000K)-ELUM091
•1x150WwarmwhiteCOBLED(3200K)-ELUM092
•1x150WcoolwhiteCOBLED(6000K)-ELUM093
•Manuallyadjustablebeamangle:12°-60°
•CRI>95
•1.6kHzrefreshrate
•DMXchannels:1or2selectable
•0-100%dimming
•4dimmingcurvesinbothLEDandhalogenprofiles:Linear,squarelaw,inversesquarelawandS-curve
•4pushbuttonmenuwithLCDdisplay
•PowerCONinputputput/output
•5-PinXLRinput/output
•3-PinXLRinput/output
•Temperaturecontrolledfancooling
•Handleonrearpanel
•Filterframeandbarndoorsincluded
ZF LED Zoom Fresnel
Specifications ZF LED Zoom Fresnel
Powerconsumption 120W-100WVersion
Powerconsumption 170W-150WVersion
Powersupply 100~240V,50/60Hz
Dimensions 430x270x340mm
Weight 7.3kg
Ordercode ELUM090-100WWWVersion
Ordercode ELUM091-100WCWVersion
Ordercode ELUM092-150WWWVersion
Ordercode ELUM093-150WCWVersion
0m 1m 2m 3m 4m 5m
60°12°
206008630
51602160
2290958
1290539
825345
12° - Lux60° - Lux
100W WW
200007880
50001970
2220875
1250492
800315
12° - Lux60° - Lux
100W CW
2440010200
60902560
27101140
1520641
975410
12° - Lux60° - Lux
150W WW
3380014800
84503690
37601640
2110922
1350590
12° - Lux60° - Lux
150W CW425mm
345mm
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 4
DMX channel mode:
OperatinginDMXcontrolmodegivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.
Toaccessthe1channelDMXmode,pressthe“MENU”buttonontherearoftheunittoshow“DMX-1CH”ontheLCDdisplay.Thefixtureisnowin1Channelmode.Nowusethe“UP”and“DOWN”buttonstosetthedesiredDMXaddressforthe1Channelmode.
Toaccessthe2channelDMXmode,pressthe“MENU”buttonontherearoftheunittoshow“DMX-2CH”ontheLCDdisplay.Thefixtureisnowin2Channelmode.Nowusethe“UP”and“DOWN”buttonstosetthedesiredDMXaddressforthe2Channelmode.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Technical specifications
Operating instructions
01-Earthpoint
02-LCDdisplay
03-Functionbuttons
04-3-PinDMXinput
05-3-PinDMXoutput
06-5-PinDMXinput
07-5-PinDMXoutput
08-PowerCONinput
09-PowerCONoutput
10-FuseT3.15A250V
11-Adjustablezoomknob
Inthebox:1 x fixture, 1 x 13A powerCON mains cable & 1 x user manual
DMX INPUT
DMX OUTPUT
DMX INPUT
DMX OUTPUT
FUSE: T3.15A 250V(T6.3A 125V)
ZOOM
POWER INPUT
100-240V~50/60Hz
POWER OUTPUT
100-240V~50/60Hz
www.prolight.co.uk
ZF Zoom Fresnel
MENUINFO UP DOWN
0507 1011
06 04 0102 03
09 08
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 5
Manual dimming mode:
Toaccessthesoundactivemode,pressthe“MENU”buttonontherearoftheunittoshow“WhiteSet”ontheLCDdisplay.Theunitisnowinmanualdimmingmode.Nowusethe“UP”and“DOWN”buttonstosetthebrightnessfrom“0” - “255”(0 = LED off, 255 = LED at full brightness).
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Dimming curves
Toaccesstheunitsdimmercurves,pressthe“MENU”buttonontherearoftheunittoshow“Led Linear”ontheLCDdisplay.Nowusethe“UP”and“DOWN”buttonstosetthedimmingcurverequired.
“Led Linear”-LEDLineardimmingcurve
“Led Square”-LEDSquaredimmingcurve
“Led InvSquar”-LEDInverseSquaredimmingcurve
“Led S-Curve”-LEDS-Curvedimmingcurve
“Halgen Linear”-HalogenLineardimmingcurve
“Halgen Square”-HalogenSquaredimmingcurve
“Halgen InvSquar”-HalogenInverseSquaredimmingcurve
“Halgen S-Curve”-HalogenS-Curvedimmingcurve
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Channel Value Function
1 000-255 Masterdimmer(0-100%)
2 000-014 DimmingCurves(setviaunit)
015-044 LinearHalogendimmingcurve
045-074 SquareHalogendimmingcurve
075-104 InverseSquareHalogendimmingcurve
105-134 S-curveHalogendimmingcurve
135-164 LinearLEDdimmingcurve
165-194 SquareLEDdimmingcurve
195-224 InverseSquareLEDdimmingcurve
225-255 S-curveLEDdimmingcurve
2 channel mode:
Channel Value Function
1 000-255 Masterdimmer(0-100%)
1 channel mode:
Pleasenote:Dimmingcurvesfor1channelmodecanbesetviainternalmenu.
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 6
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-511.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:
CABL10 – 2mCABL11 – 5mCABL12 – 10m
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 7
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmissionproblemsandinterference.ItisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.
5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C
3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)
3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)
5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C
DMX setup
www.prolight.co.uk ZF LED Zoom Fresnel User Manual 8
WEEE notice
Correct Disposal of this Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.