your reliable energy solution partner
TRANSCRIPT
MP:+86 176 9134 2988Tel:+86 0755 8520 9056Web:www.luxpowertek.comEmail:[email protected]
301, 3rd Floor, Building B1, Weiye Innovation 18th IndustrialPark, Baoyuan Road, Baoan District, Shenzhen, Guangdong, China
Y o u r R e l i a b l e E n e r g y S o l u t i o n P a r t n e r
“ Luxpower haspowered over
10000+ householdsall over the world,
in hybrid / AC couple/ off-grid scenarios.
We are committed to making our usersbenefit from thesun and enjoy
life”
Grid
Diesel Generator
Wind Power
Optional AC Power Sources
RouterLux Power Viewer
LXP Hybrid Inverters
ACInterface
ACInterface
UPSInterface
UPSInterface
X
Micro-grid AC Bus
Micro-grid Loads
Grid
Router
Lux Power Viewer
LXP Hybrid or LXP ACS inverters
System Connection Paralleling Extensions
A newly designed solar andenergy storage hybrid inverter,installed in on-grid solar, off-gridsolar and back-up systems.
LXP Hybrid enables a programmable andschedulable smart solar energy storagesystem to help increase your solar energyself-consumption rate, protect your homeappliances from grid outage, andbalance your energy usage strategyto save energy bill.
Paralleling LXP inverters inone phase to extend thesingle phase system capacityfor either hybrid or ACcoupled energy storageapplications.
Paralleling LXP inverters (singlephase inverters) to build a threephase system for either hybrid orAC coupled energy storageapplications.
Smart paralleling algorithmenable multiple configurableworking modes under on-grid,off-grid or micro-grid applications.
Hybrid LXP 3-6kW
Hybrid LXP 8-12kW / 8-12kW US
Hybrid LXP 4-6kW HBECO Hybrid SNA 3-5kW
Home load power
Battery discharge
PV power
for home load consumptionPV power used
Battery discharge
Battery charge
PV Power
00:00 07:00 12:00 19:00 24:00
Home load power usage
for home load consumptionPV power used
for home load consumptionPV power used
Battery charge
DischargeCharge
Discharge
00:00 07:00 12:00 19:00 24:00
PV Power Home load power usage
Self ConsumptionForce Time Use
Y o u r R e l i a b l e E n e r g y S o l u t i o n P a r t n e r
Advanced Parallel
Up to10 units parallel, expandable to120kW
No limits on cable length connecting to battery or ACSingle phase and unbalanced three phase paralleling
Key Features
Light, fast & easy installationFree & handy monitoring on mobile / PC
Generator interface availableMulti phases output on differnt hybrid models
Smart UPS
Sufficient backup power for emergency usePlug & Play, seamless switching under 10ms
Intelligent working modes
Self consumption mode for high tariff areas
Force charge & discharge mode for areas where tariff varies by timeCharge priority mode for areas where grid power is unstable
Easy to use with battery
Battery sharing with multi-inverters in single phase or three phase
Wide range of compatible battery brands
Essential info uploaded to Lux server for quick ESS diagnosis
Remote upgrade BMS firmware
Wake up lithium battery from sleep mode
Force time use mode, where there is a big difference tariff times.
This mode suits for situation where the price difference of energy is big. User can set the charging and discharging time and priority of energy use under Force Time Use mode. The user can alsochoose whether to charge the battery using grid power if the regulations permitted.
Under self consumption mode the energy generated by PV will be mainlyused by local loads, and rest will be stored in the battery, excessive powerwill be fed back into the grid.
This is the default mode which will increase the self consumption rate and reduce the energy billsignificantly.
LXP3-6KIP65, indoor & outdoor use
Stronger UPS
Intelligent working modes
Easy to use with battery
Advanced Parallel, up to 60kW
Plug & Play, seamless switching under 10ms
Solar
Battery
LXP3.6K/4kMax. DC Input PowerNominal DC Input VoltageDC Input Voltage RangeMPPT Voltage RangeStart-up VoltageMPPT NumberMax. DC Input Current
Compatible Battery TypeNominal Battery VoltageBattery Voltage RangeMax. Charge/Discharge CurrentMax. Charge/Discharge PowerCharging CurveMax. Charge VoltageCapacity of Battery
GridNominal AC Output PowerMax. AC Output PowerMax. AC Output CurrentNominal AC VoltageAC Voltage RangeNominal AC FrequencyAC Frequency RangePower FactorTHDI
UPS Max. Output Power without SolarUPS Max. Output Power with SolarUPS Nominal Output VoltageUPS Nominal Output FrequencyUPS Nominal Output CurrentPeak Power Without SolarTHDVSwitching Time
E�ciencyEurope E�iciencyMax. E�iciencyBattery Charge/Discharge E�iciency
ProtectionReverse Polarity ProtectionOver Current/Voltage ProtectionAnti-islanding ProtectionAC Short-ciruit ProtectionLeakage Current ProtectionGround Fault MonitoringGrid MonitoringIngress Protect DegreeDC Switch
GeneralDimensions (W/H/D)WeightTopologyCooling ConceptRelatively HumidityOperating Temperature RangeAltitudeNoise EmissionStandby ConsumptionDisplay & Communication Interfaces
LXP3K6600W
360V.d.c100 - 550V.d.c120 - 500V.d.c
140V.d.c2
12.5A/12.5A
7000W360V.d.c
100 - 550V.d.c120 - 500V.d.c
140V.d.c2
12.5A/12.5A
Lithium-ion/Lead-Acid48V.d.c
40 - 60V.d.c66A/66A
3600W/3600W3 stages
59V2-20kWh
3000W3000VA
15A230V.a.c
180 - 270V.a.c50Hz / 60Hz
45 - 55Hz / 55 - 65Hz
<3%
3000W3000W
230V.a.c50Hz / 60Hz
13A4500W, 30s
<5%Typical 0.01s
97.5%97.9%94.5%
YesYesYesYesYesYesYes
IP65 / NEMA4XYes
455 / 476 (565) / 18120 kg
Natural Convection0-100%-25 - 60
<2000m<25dB<5W
LCD, RS485, Wi-Fi, Ethernet
3600W/4000W3600VA/4000VA
16A/20A230V.a.c
180 - 270V.a.c50Hz / 60Hz
45 - 55Hz / 55 - 65Hz
<3%
3600W/4000W3600W/4000W
230V.a.c50Hz / 60Hz15.6A/17.4A4500W, 30s
<5%Typical 0.01s
97.5%97.9%94.5%
YesYesYesYesYesYesYes
IP65 / NEMA4XYes
455 / 476 (565) / 18120 kg
Natural Convection0-100%-25 - 60
<2000m<25dB<5W
LCD, RS485, Wi-Fi, Ethernet
Lithium-ion/Lead-Acid48V.d.c
40 - 60V.d.c66A/66A
3600W/3600W3 stages
59V2-20kWh
LXP6K8000W
360V.d.c100 - 550V.d.c120 - 500V.d.c
140V.d.c2
12.5A/12.5A
6000W6000VA
26A230V.a.c
180 - 270V.a.c50Hz / 60Hz
45 - 55Hz / 55 - 65Hz
<3%
4000W6000W
230V.a.c50Hz / 60Hz
17.4A4500W, 30s
<5%<0.01s
97.5%97.9%94.5%
YesYesYesYesYesYesYes
IP65 / NEMA4XYes
455 / 476 (565) / 18120 kg
Natural Convection0-100%-25 - 60
<2000m<25dB<5W
LCD, RS485, Wi-Fi, Ethernet
Lithium-ion/Lead-Acid48V.d.c
40 - 60V.d.c80A/80A
4000W/4000W3 stages
59V2-20kWh
UPS
Tranformerless (solar), HF (Battery)
LXP4.6K/5K8000W
360V.d.c100 - 550V.d.c120 - 500V.d.c
140V.d.c2
12.5A/12.5A
4600W/5000W4600VA/5000VA
25A230V.a.c
180 - 270V.a.c50Hz / 60Hz
45 - 55Hz / 55 - 65Hz
<3%
4000W5000W
230V.a.c50Hz / 60Hz
17.4A4500W, 30s
<5%Typical 0.01s
97.5%97.9%94.5%
YesYesYesYesYesYesYes
IP65 / NEMA4XYes
455 / 476 (565) / 18120 kg
Natural Convection0-100%-25 - 60
<2000m<25dB<5W
LCD, RS485, Wi-Fi, Ethernet
Lithium-ion/Lead-Acid48V.d.c
40 - 60V.d.c80A/80A
4000W/4000W3 stages
59V2-20kWh
Adjustable 0.8 overexcited to 0.8 underexcited
SPECIFICATION
LXP8-12k / 8-12k US
HYB
RID
IN
VERT
ER
Advanced parallel, up to 120kW
Stronger UPS
Plug & Play, seamless switching under 10ms
Color LCD, IP65
Easy to use with battery
Split phase output available for US model
Separate generator interface available
Optional 10 year warranty for US
Host inverter automatically generated tomanage entire system
SPECIFICATION
TypeMax charge/discharge current(A)Nominal voltage(V)Voltage range(V)
BatteryLead-acid /Lithium
22048
40-60
LXP 9K LXP 10KLXP 7.6K/8KSolar LXP 12KMax usable input current(A) Max short circuit input current(A) Start input voltage(V)Startup voltage(V)Full power MPPT voltage range(V)DC nominal voltage(V) MPPT trackerDC voltage range(V)MPPT operating voltage range(V)Max power(W) Number of MPPT(Strings per MPPT)
15/15/1517/17/17
100140
170-480360
100-60060-480
7000/7000/70003(1/1/1)
GridNominal output current(A)Max output current(A)Rated voltage(V) Operating voltage range(V)Nominal power output(W)Max. apparent AC power(VA)Operating frequency(Hz)Operating frequency range(Hz)Phase shi� (cosφ)Reactive power adjust rangeTHDI
31.6/33.337
240180-270
8000890050/60
45-55/55-650.99@full load
-0.8~+0.8<3%
E�ciencyEU E�iciencyMax.E�iciency@PV to gridMax. E�iciency@ battery to gridMPPT E�iciency
98%97.5%95%
99.9%
ProtectionIntegrated disconnectReverse polarity protectionDC switch rating for each MPPTOutput over voltage protectionOutput over current protectionGround fault monitoringGrid monitoringPole sensitive leakage current monitoringAFCIRSD
DC switchYESYESYESYESYESYESYESOPTOPT
UPSNominal output current(A) Nominal output voltage(V) Rated output power (VA)Operating frequency(Hz)Peak power(VA)THDvSwitch time(ms)
33.3240
800050/60
<3%<20
GeneralDimensions(mm)Weight(Kg)Degree of protectionCooling conceptTopologyRelative humidityAltitude(m)Noise emission(dB)Internal consumption(W) DisplayCommunication interfaceStandard Warranty
650*440*22038kgIP65FAN
Transformer-less0~100%
<2000<50<15
Touch color screen485/Wi-Fi/CAN
5/10 years
Lead-acid /Lithium 22048
40-60
15/15/1517/17/17
100140
190-480360
100-60060-480
7000/7000/70003(1/1/1)
37.541
240180-270
9000990050/60
45-55/55-650.99@full load
-0.8~+0.8<3%
98%97.5%95%
99.9%
DC switchYESYESYESYESYESYESYESOPTOPT
37.5240
900050/60
<3%<20
650*440*22038kgIP65FAN
Transformer-less0~100%
<2000<50<15
Touch color screen485/Wi-Fi/CAN
5/10 years
Lead-acid /Lithium 22048
40-60
15/15/2717/17/34
100140
210-480360
100-60060-480
7000/7000/120003(1/1/2)
41.646
240180-270
100001100050/60
45-55/55-650.99@full load
-0.8~+0.8<3%
98%97.5%95%
99.9%
DC switchYESYESYESYESYESYESYESOPTOPT
41.6240
1000050/60
<3%<20
650*440*22038kgIP65FAN
Transformer-less0~100%
<2000<50<15
Touch color screen485/Wi-Fi/CAN
5/10 years
Lead-acid /Lithium 22048
40-60
15/15/2717/17/34
100140
230-480360
100-60060-480
7000/7000/120003(1/1/2)
5055
240180-270
120001320050/60
45-55/55-650.99@full load
-0.8~+0.8<3%
98%97.5%95%
99.9%
DC switchYESYESYESYESYESYESYESOPTOPT
50240
1200050/60
<3%<20
650*440*22038kgIP65FAN
Transformer-less0~100%
<2000<50<15
Touch color screen485/Wi-Fi/CAN
5/10 years
1.1xPn/30min 1.25xPn/5min 1.5xPn/30s 2xPn/10s
4-6K HB
High voltage, higher efficiency
Free monitoring & remote upgrade
IP65, indoor & outdoor use
Stronger UPS
Intelligent working modes
Easy to use with battery
Advanced Parallel, up to 60kW
Plug & Play, seamless switching under 10ms
SPECIFICATIONSolar
Battery
LXP5K HB LXP6K HBMax. DC Input PowerDC Input Voltage RangeGrid Full-load MPPT VoltageStart-up VoltageMPPT NumberString per MPPTMax. DC Input Current
Compatible Battery TypeNominal Battery VoltageBattery Voltage RangeMax. Charge/Discharge CurrentMax. Charge/Discharge PowerCharging Curve
GridNominal AC Output PowerNominal AC Output CurrentMax. AC Output CurrentNominal AC VoltageOptional AC Voltage RangeNominal AC FrequencyAC Frequency RangePower FactorTHDI
UPS Nominal PowerUPS Nominal VoltageUPS Nominal FrequencyUPS Nominal CurrentPeak PowerTHDVSwitching Time
E�ciencyMPPT E�iciencyEurope E�iciencyMax. E�iciencyMax. Charge/Discharge E�iciency
ProtectionReverse Polarity ProtectionOver Voltage,Over CurrentAnti-islanding ProtectionAC Short-ciruit ProtectionLeakage Current ProtectionGround Fault MonitoringGrid MonitoringIngress Protect DegreeDC Switch
GeneralDimensions (W/H/D)WeightTopologyCooling ConceptRelatively HumidityAltitudeNoise EmissionStandby ConsumptionDisplay/Communication InterfaceStandard Warranty
LXP4K HB7000W
90-550V.d.c200 - 500V.d.c
120V.d.c2
1/112.5A/12.5A
8000W90-550V.d.c
200 - 500V.d.c120V.d.c
21/1
12.5A/12.5A
8000W90-550V.d.c
300 - 500V.d.c120V.d.c
21/1
12.5A/12.5A
Lead-Acid, Li-on etc.250V.d.c
90 - 450V.d.c20A/20A
4000W/4000W3-stages
4000W17.5A22A
230V183~264V50/60Hz
45-55Hz/55-65Hz
<3%
4000W230Vac
50/60Hz17.5A
5000W, 30s<3%@R-loadTypical 0.01s
5000W230Vac
50/60Hz21.7A
6200W, 30s<3%@R-loadTypical 0.01s
6000W230Vac
50/60Hz21.7A
6900W, 30s<3%@R-loadTypical 0.01s
>99%96.5%97.5%
97%/ 96.6%
>99%96.3%97.5%
97%/ 96.6%
>99%96.3%97.5%
97%/ 96.6%
YesYesYesYesYesYesYes
IP65Integrated
YesYesYesYesYesYesYes
IP65Integrated
YesYesYesYesYesYesYes
IP65Integrated
455 / 476 / 18120 kg
TransformerlessNatural Convection
0-100%<2000m<25dB<10W
LCD/ LED/RS485/ Wi-Fi/ CAN5 year
5000W21.7A27A
230V183~264V
50Hz / 60Hz45-55Hz/55-65Hz
>0.99@rated power 0.8lagging-0.8 leading Adjustable
<3%
6000W26A30A
230V183~264V
50Hz / 60Hz45-55Hz/55-65Hz
<3%
Lead-Acid, Li-on etc.250V.d.c
90 - 450V.d.c25A/25A
5000W/5000W3-stages
Lead-Acid, Li-on etc.250V.d.c
90 - 450V.d.c25A/25A
6000W/6000W3-stages
UPS
455 / 476 / 18120 kg
TransformerlessNatural Convection
0-100%<2000m<25dB<10W
LCD/ LED/RS485/ Wi-Fi/ CAN5 year
455 / 476 / 18120 kg
TransformerlessNatural Convection
0-100%<2000m<25dB<10W
LCD/ LED/RS485/ Wi-Fi/ CAN5 year
Home load power
Battery discharge
PV power
for home load consumptionPV power used
Battery discharge
Battery charge
Power limited
00:00 07:00 12:00 19:00 24:00
PV Power Home load power usage
Grid
Diesel Generator
Optional AC Power Sources
RouterLux Power Viewer
SNA5000 Inverters
Micro-grid AC Bus
Micro-grid Loads
OFF GRIDInterface
ACInterface
ACInterface
OFF GRIDInterface
System Connection Working Mode
ECO
Hyb
rid
SN
A 3
-5K
ECO Hybrid
With thousands of hybrid inverters & AC units installed around the world.Lux power has stepped even futher to bringingpower to every home, with or without grid power.
ECO Hybrid SNA 3-5K is now available for homes without grid. Inquire your local distributor, re-organize your power at home.No more blackouts.
SNA 3-5kW series off grid inverters can support the system to work as a back-up poweror a replacement of diesel generator. Since the inverter support paralleling function, the capacity of system can range from 3kW to 50kW. The inverter support severalworking modes.Pure off-grid working mode: working as traditional off grid inverters, can set output toutility first , battery first or solar first.Hybrid working mode: working as a hybrid, support solar and utility jointly take the load,can set to self consumption mode or charge priority mode.
Off grid system is a good solutionfor the area where the grid poweris unstable or there is no electricityat all.
Advantage of solar power:
Easy to install Efficient Cost-effictive Environment-friendly
Can partially or completelyreplace diesel generator.
Flexible from 3 to 50kW
SNA 3-5k Reclaim Your Power
Intelligent offgrid & hybrid modes
Single phase or unbalanced three phase
Free monitoring & remote upgrade
Wide PV input voltage range
PV & AC power loads simultaneously
Easy to use with battery
Advanced Parallel, up to 50kW
Separate generator interface available
Host inverter automatically generated tomanage entire system
N o M o r e B l a c k o u t s
SPECIFICATION
Battery
Grid
Solar
Rated power
Parallel capacity
Normal output voltage
Normal output frequency
Surge power
Switch time
Wave form
Max. Recommended PV Power
MPPT Tracker
Max. PV Open Circuit Voltage
MPPT Voltage Range
Max. Solar Charge Current
Max. Solar Input Current
Max. MPPT E�iciency
Parallel MPPT Charger
3200W/3200W
2
480Vdc
100-385Vdc
100A
13A/13A
>98%
YES
3200W/3200W
2
480Vdc
100-385Vdc
100A
13A/13A
>98%
YES
3200W/3200W
2
480Vdc
100-385Vdc
100A
13A/13A
>98%
YES
Battery Type
Normal Voltage
Max. Charge Voltage
Normal Voltage
AC Voltage Range
Max. Charge Current
Frequency Range
Dimensions(W/H/D)
Weight
Protection Degree
Relative Humidity
Operating Temperature
Storage Temperature
Display
Lithium Battery Communication
RS485/Dry Connector
Wifi/GPRS
Warranty
LCD+LED
CAN/RS485
YES/YES
YES/YES
2 year
LCD+LED
CAN/RS485
YES/YES
YES/YES
2 year
LCD+LED
CAN/RS485
YES/YES
YES/YES
2 year
330x504x135mm
14Kg
IP20
5%~95% Relative Humidity(Non-condensing)
0°C~50°C
-15°C~60°C
330x504x135mm
14Kg
IP20
5%~95% Relative Humidity(Non-condensing)
0°C~50°C
-15°C~60°C
330x504x135mm
14Kg
IP20
5%~95% Relative Humidity(Non-condensing)
0°C~50°C
-15°C~60°C
230Vac
110-280Vac
60A
50/60Hz(Auto Sensing)
230Vac
110-280Vac
60A
50/60Hz(Auto Sensing)
230Vac
110-280Vac
60A
50/60Hz(Auto Sensing)
Lithium/Lead-Acid
51.2V/48V
59V
Lithium/Lead-Acid
51.2V/48V
59V
Lithium/Lead-Acid
51.2V/48V
59V
Output SNA3000 SNA4000 SNA50003000W/3000VA
YES
230/240,Split phase 220/110 Vac *
50/60Hz
6000VA
10ms
Pure sine wave
4000W/4000VA
YES
230/240,Split phase 220/110 Vac *
50/60Hz
8000VA
10ms
Pure sine wave
5000W/5000VA
YES
230/240,Split phase 220/110 Vac *
50/60Hz
10000VA
10ms
Pure sine wave
*For Split phase version
LXP ACS 3600LXP SQPOD 3600
Your Solar System
One Stepto Retrofit
Y o u r R e l i a b l e E n e r g y S o l u t i o n P a r t n e r
Grid
RouterLux Power Viewer
AC ESS Inverter
A CIn te r fa c e
U P SIn te r fa c e
Micro-grid Loads
Existed On-gridSolar S ystem
H ome l oa d powe r
B a tte ry d is c ha rge
for h ome l oa d c ons umptionP V p owe r u s e d
B a tte ry d is c ha rge
B a tte ry c ha rge
Existing On-grid Solar System
C ha rge
D is c ha rge
D is c ha rge
C ha rge
for h ome l oa d c ons umption
P V p owe r u s e d
00:00 07:00 12:00 19:00 24:00
Home load power usage
To retrofit existing on-gridsolar system to energystorage hybrid system
It couldn’t be easierthan installing a LXPAC series invertercoupled on AC sidewith a battery pack.
System Connection
Under self use mode, AC coupled inverter will detect the power of on-gridinverter generated, which will be used by local loads first, and rest will bestored in the battery by using AC coupled inverter,excessive power will befeed back into the grid.This is the default mode which will increase the selfconsumption rate and reduce the energy bill significantly.
This mode suits for situation where the price difference of energy is big. Usercan set the charging and discharging time and priority of energy use underForce Time Use Mode. The user can also choose whether to charge thebattery using grid power if the regulations permitted.
Self Consumption Force Time Use
Advanced Parallel for SQPOD
Up to10 units parallel, expandable to 36kW
No limits on cable length connecting to battery or ACHost inverter automatically generated to manage entire system
Single phase and unbalanced three phase paralleling
Smart UPS
Sufficient backup power for emergency usePlug & Play, seamless switching under 10ms
Intelligent working modes
Self consumption mode for high tariff areas
Force charge & discharge mode for areas where tariff varies by timeCharge priority mode for areas where grid power is unstable
Easy to use with battery
Flexible connections with battery, group or split both accessible
Wide range of compatible battery brands
Essential info uploaded to Lux server for quick ESS diagnosis
Remote upgrade BMS firmware
Wake up Lithium battery when battery shutdown
A RealPlug & PlayUnit thatHelps youDo Allin One Step.
Stronger UPS
Free monitoring & remote upgrade
IP65, indoor & outdoor use
Generator interface available
Intelligent working modes
Easy to use with battery
Retrofit any on-grid systems to be able to run battery
Plug & Play, seamless switching under 10ms
AC Coupled InverterLXP ACS 3600
AC
S3
60
0
SPECIFICATION
Compatible Battery TypeNominal Battery VoltageMax. Charging Voltage(V)Max. Charge/Discharge CurrentBattery Capacity(Ah)Charging Mode for Li-Ion BatteryCharging for Lead-acid BatteryBattery Back Feed Current
ACS 3.6k
Grid
Lithium-ion, Lead-Acid etc.48V.d.c
<=60 V(Configurable)70A / 70A
100AhSelf-adaption to BMS
3-stage adaptive with maintenance0A
Nominal AC Output Power to UtilityMax. AC Output Power to UtilityMax. AC Input Power from UtilityMax. AC Output Current to UtilityMax. AC Input Current From UtilityNominal Output VoltageAC Voltage RangeNominal AC FrequencyAC Over Current ProtectionPower FactorTHDIAC Over Voltage Category
UPSMax. Output PowerNominal Output VoltageNominal Output FrequencyMax. Output Current Peak PowerTHDV(linear load)Switching TimeBack-up Over Current Protection
E�ciencyMax. Charge/Discharge E�iciency
General Data
Standards
Dimension(mm)WeightTopologyCooling ConceptRelatively HumidityAltitudeNoise EmissionStandby ConsumptionDisplay & Communication Interfaces
3600VA3600VA5980VA
16A26A
220/230V.a.c180 - 270V.a.c
50Hz/60Hz31A
1(adjustable 0.8leading -0.8lagging)<3%
Category III
3600VA230V.a.c
50Hz / 60Hz16A
4500VA, 30s<3%
Typical 0.01s31A
650*440*22015.6 kg
HFNatural Convection
100%<2000m<25dB
<5WLCD, LED, RS485, Wi-Fi, CAN
G83, G100,CE,SAAEN61000-6-3
96%
ProtectionReverse Polarity ProtectionOver Current/Voltage ProtectionAnti-islanding ProtectionAC Short-circuit ProtectionLeakage Current ProtectionGround Fault MonitoringGrid MonitoringIngress Protection Degree
YESYESYESYESYESYESYES
IP65 / NEMA4X
Battery
Stronger UPS
IP65, indoor & outdoor use
Intelligent working modes
Generator interface available
Advanced Parallel, up to 36kW
Free monitoring & remote upgrade
Plug & Play, seamless switching under 10ms
Retrofit any on-grid systems to be able to run battery
AC Coupled Inverter SPECIFICATION
Compatible Battery TypeNominal Battery VoltageMax. Charging Voltage(V)Max. Charge/Discharge CurrentBattery Capacity(Ah)Charging Mode for Li-Ion BatteryCharging for Lead-acid BatteryBattery Back Feed Current
SQPOD 3.6k
Grid
Lithium-ion, Lead-Acid etc.48V.d.c
<=60 V(Configurable)70A / 70A
100AhSelf-adaption to BMS
3-stage adaptive with maintenance0A
Nominal AC Output Power to UtilityMax. AC Output Power to UtilityMax. AC Input Power from UtilityMax. AC Output Current to UtilityMax. AC Input Current From UtilityNominal Output VoltageAC Voltage RangeNominal AC FrequencyAC Over Current ProtectionPower FactorTHDIAC Over Voltage Category
UPSMax. Output PowerNominal Output VoltageNominal Output FrequencyMax. Output Current Peak PowerTHDV(linear load)Switching TimeBack-up Over Current Protection
Max. Charge/Discharge E�iciency
General Data
Standards
Dimension(mm)WeightTopologyCooling ConceptRelatively HumidityAltitudeNoise EmissionStandby ConsumptionDisplay & Communication Interfaces
3600VA3600VA5980VA
16A26A
220/230V.a.c180 - 270V.a.c
50Hz/60Hz31A
1(adjustable 0.8leading -0.8lagging)<3%
Category III
3600VA230V.a.c
50Hz / 60Hz16A
4500VA, 30s<3%
Typical 0.01s31A
650*440*22015.6 kg
HFNatural Convection
100%<2000m<25dB
<5WLCD, LED, RS485, Wi-Fi, CAN
G83, G100,CE,SAAEN61000-6-3
96%
ProtectionReverse Polarity ProtectionOver Current/Voltage ProtectionAnti-islanding ProtectionAC Short-circuit ProtectionLeakage Current ProtectionGround Fault MonitoringGrid MonitoringIngress Protection Degree
YESYESYESYESYESYESYES
IP65 / NEMA4X
Battery
E�ciency
LSP 100KDC/DC
Retrofit on grid system to energy storage hybrid system
DC coupled, 24strings Solar input and 12 strings output
Handy apps available on mobile
Advanced power management
IP65 design, quick installation
Touch screen, free monitor
Flexible accout settings for multi level type users
Intelligent data collection for remote service assistance
SPECIFICATION
Max. input powerMax. input voltageinput nominal voltageinput voltage rangeStart voltageMax. short current per MPPTMax current per MPPT inputNumber of MPPT tracksNumber of input strings
DCDC output rated powerNormal output voltageOutput voltage rangeMax output currentOutput stringsOutput tracks
DisplayWiFi
Dimensions (W x H x D)Weight (with mounting plate)Protection DegreeTopologyCooling MethodRelative HumidityOperating Temperature RangeConnector(PV input and Output)Max. Operating AltitudeWarranty
TBDTBDIP65
TransformerlessAir cooling
0%~100% Relative Humidity(Non-condensing)
-25°C ~ 60°C Amphenol UTX
2000m5 year
LED+LCD/Touch bottonYes
YesType II
Lead-acid/Lithium100kW
300~700Vdc200A
98.7%(TBD)
100kW650V
500~1000V20A1212
200kW1,000V630V
300-1000V330V40A26A1224
DC Reverse-polarity ProtectionDC Surge Arrester
TypeMAX charge and discharge powerVoltage rangeMAX charge and discharge currentMax charge and discharge e�iciency
Output
Protection
Communication
General
Battery
LSP 100kInput
Standards EN 62109-1/-2, IEC 62109-1/-2
TopEnergyStorageApp
Nominated by LeapDroid UKhttps://leapdroid.com/?p=6076
Android IOS
AppPC
4G 4G
Internet
InternetInternet
Router
WiFi WLAN GPRS/3G/4G
Base StationRouter
WiFi WLAN GPRS/3G/4G
Base Station
Intelligent PowerManage System
Intelligent Power Manage System
+86 176 9134 2988+86 0755 8520 9056www . luxpowertek.com
301, 3rd Floor, Building B1 Weiye Innovation 18th Industrial Park
Baoyuan Road, Baoan District, Shenzhen, Guangdong, China
Luxpower has dedicated to making things easier since day 1.Thanks to the greatly accessible monitor and management,All needs from users, installers, distributors, can be met.
IntelligentPowerManagementSystem
CertificateCertificate
www.luxpowertek.com
Your Reliable Energy Solution Partner